On -Site Wastewater Disposal System Permit
Permit Number: OSP251091
Work Type: Septic Initial
Tax Code Number: 09004214000
Site Legal Address: CHUGACH PARK VIEW LT 14 GA456
Site Mailing Address:
Owner: MORTENSEN DAVID & BATES GWENDO
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Effective Date:
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
OrpartInent
4/28/2025
4/28/2026
111967
2 Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: _ �� P— �i Date:
Issued By: �� �— Date:
5
ON -SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 090-042-14
Property owner(s) David Mortensen
Day phone (907) 243-4476
Mailing address 4820 Kalenka Circle, Anchorage, AK 99502
Site address 741 Rand Dr, Indian, AK 99540
Legal description Chugach Park View, Lot 14
Number of Bedrooms - 'S*
Engineering Firm Forge Engineering
Building Permit NumberF�: z a_ — / � / I Not Applicable 9
APPLICATION IS FOR: APPLICATION IS AN:
(Z all that apply)
Absorption Field El Initial 0
Septic Tank M Upgrade ❑
Holding Tank R Renewal ❑
Privy EJ
Well 01,
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Permit/Rush Fees: - 9 �—
Date of Payment:— 71'tv
� foe
Permit No.
Waiver Fees:
Date of Payment:
Waiver No.
Distance:
April 4, 2025
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Chugach Park View Lot 14 – Rand Drive
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot intends to build a 5-bedroom home on the property, so we are
submitting this permit application for the construction of a new well and septic system. The
attached site plan identifies the location of the home as well as the proposed well, septic location
and alternate site. No conflicts exist between this proposed system and any other well or septic
system, whether on this lot or adjacent lots.
The ground surface on the lot slopes moderately downhill from the north to the south. There are
no slopes greater than 25% within 50 feet downslope of either the primary or alternate site.
Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage
will not impact this septic system. The new trench will be constructed parallel to the slope as much
as possible.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all
wells and surface water, and more than 5’ away from the septic tank. The alternate site is located
more than 6’ away. Please refer to the subdivision test hole logs as well as the plan and profile
pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent
properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251091, Curtis Townsend, 04/28/25
ALTERNATE SITE
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
1"=50'
(2)x 75' LONG x 5' WIDE, 0.5'
EFFECTIVE DEPTH
ABSORPTION TRENCHES
1500-GAL
SEPTIC TANK
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
TH#14
CHUGACH PARK VIEW LOT 14
FEET
0 50 100
≥6'
FCO
R
A
N
D
D
R
I
V
E
5-BDRM HOME
90
SEPTIC PLAN
4/4/25
15' SIDE SETBACK
40' T&E EASEMENT
SHOP
12
.
5
'
S
E
C
O
N
D
A
R
Y
F
R
O
N
T
S
E
T
B
A
C
K
2
5
'
F
R
O
N
T
S
E
T
B
A
C
K
85
80
75
MT
MT
MT
MT
NEW WELL
500-GAL LIFT
STATION
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251091, Curtis Townsend, 04/28/25
CHUGACH PARK VIEW LOT 14
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
DRAINFIELD ROCK
3'
2'
DESIGN FACTORS:SYSTEM REQUIREMENTS:
750 GPD PEAK FLOW
PERK RATE: <1 MIN/IN
APPLICATION RATE: 1 GPD/SF
5' WIDE TRENCH SYSTEM
1500-GAL SEPTIC TANK
BOTTOM OF TRENCH: 3.5' BELOW GRADE
FLOW LINE ELEVATION: 3' BELOW GRADE
750 GPD / 1 GPD/SF / 5' WIDE * 1 RED FACTOR [0.5 DEEP] = 150 LF TRENCH REQUIRED (150 LF SPECIFIED)
GEOTEXTILE FABRIC
6"
4/25/25
PROVIDE ADDITIONAL FILL TO
ACCOUNT FOR SETTLEMENT
5'
MOA APPROVED SAND
11
4" PVC w/ 1
8" ORIFICES
EVENLY SPACED @ 5'
OC
6" MIN
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251091, Curtis Townsend, 04/28/25
A L A S K A «T A T E R & N V A S T E W A T E R
C O N S U LT A N T S , IN C .
LEGAL DESCRIPTION:CHUGACH PARK SUBDIVISION; PROPOSED LOT 14,
PERFORMED FOR:BELL k ASSOCIATES DATE: 1/ 30/ 2003
DEPteat TEST HOLE 14
1 ORGANICS
m
4
FAR 1
NIHMI 1t
N21191 Il///%
NNE
111111111
GP - SP W/5'
LARGE
MOO
4:50
COBBLES AND
6 SOME SILT
3 4:50
LENSES
7 1' .
8
DATE
FAR 1
NIHMI1t
N21191 Il///%
NNE
111111111
6'-
pal MOO
4:50 1
10
3 4:50
M L
11
12-2
4:51 1 0' 6'
13-
131415161718
4:5114-
15-
4:52 1
16-
17-
181
19
DEPTH TO
GROUNDWATER DATE
F A R 1
NIHMI1t
N21191 Il///%
N N E
111111111
6'-
pal M O O
4:50 1
B
3 4:50
DEPTH TO
GROUNDWATER DATE
DRY 1/ 3 0/ 2 0 0 3
8. 5'2/ 7/ 2 0 0 3
7. 8'10/ 14/ 2002
6'-
SEE ATTAC H ED
SITE PLAN
D ATE READING CLOCK
TIM E
NET TIM E
M INUTES)
WATER LEVEL NET DROP
READING ( INCHES)
1/ 3 0 / 2 003 1 4:49 6'-
2 4: 50 1 0'6-
3 4: 50 6- -
4 4: 51 1 0'6'
5 4: 51 6' -
6 4: 52 1 0 '6'
PERCOLATION RATE <1 ( M IN ./ IN C H)PERC. HOLE DIA. 6 ( INCHES)
TEST RUN BETW EEN 4.0 FT. AND 4.5 FT .
2 0 A FOUR HOUR PRESOAK WAS PERFORMED: YES O N O
SOILS LOGGED BY:MATT FISHER PERCOLATION TEST PERFORMED BY:MATT FISHER
COM M ENTS:SEPTIC SYSTEM MAY REOUIRE THE USE OF A SAND FILTER
PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS P RFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: Z 0 4 3 P 40 -
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251091, Curtis Townsend, 04/28/25