HomeMy WebLinkAboutHENKINS BLK 1 LT 10HENKINS Lot 10 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP251128 Work Type: WellSeptic Initial Tax Code Number: 05129232000 Site Legal Address: HENKINS BLK 1 LT 10 G:0755 Site Mailing Address: Owner: MIDNIGHT SUN CONSTRUCTION LLC Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft Total Bedrooms: L>cpartai�<:•nr 5/8/2025 5/8/2026 40511 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy W Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: -5 ' �- - Date: Issued By: Date: S '✓ r ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 051-292-32 Property owners) Midnight Sun Construction LLC Day phone (907)727-1433 Mailing address2000 E Dowling RD STE 8 Site address 19980 Gilbert Rd Legal description Henkins Block 1 Lot 10 Number of Bedrooms4 Engineering Firm Forge Engineering Building Permit Number R251714 Not Applicable ❑ APPLICATION IS FOR: APPLICATION IS AN: (Z all that apply) Absorption Field Initial El Septic Tank Upgrade ❑ Holding Tank ❑ Renewal ❑ Privy ❑ Well Fi THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Permit/Rush Fees:vv Date of Payrnent:. Permit No. II Waiver Fees: Date of Payment: Waiver No. Distance: May 5, 2025 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Henkins B1 L10 - 19980 Gilbert Rd Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property. This permit application is for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes toward the southwest at a relatively steady slope. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Please refer to the attached test hole logs, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251128, Curtis Townsend, 05/08/25 5 1 0 . 0 5 2 0 . 0 5 0 8 . 0 5 1 2 . 0 5 1 4 . 0 5 1 6 . 0 5 1 8 . 0 5 2 2 . 0 5 2 4 . 0 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=50' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MT - MONITORING TUBE TH - TEST HOLE LEGEND HENKINS, BLOCK 1 LOT 10 FEET 0 50 100 SEPTIC PLAN 5/1/25 GI L B E R T R O A D (2) 60' LONG x 5' WIDE, 6" EFFECTIVE DEPTH ABSORPTION TRENCHES NEW 1250-GAL SEPTIC TANK CO CO CO CO MT MT MT MT 2CO FCO EXISTING NEIGHBORING SEPTIC TH#1 PROPOSED WELL UNDEVELOPED UNDEVELOPED SEPTIC SYSTEM OUTSIDE WELL RADIUS FS ALTERNATE SITE CAT III SYSTEM 25'LF, 5' WIDE, 6" ED ENSURE >100' SEPARATION FROM WELL ON LOT 8 (LOCATION ESTIMATED) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251128, Curtis Townsend, 05/08/25 HENKINS, BLOCK 1 LOT 10 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 6" 4' 6" DESIGN FACTORS:SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: 0.07 MIN/IN APPLICATION RATE: 1.0 GPD/SF (FILTER SAND) 5-WIDE TRENCH SYSTEM WITH 2' SAND FILTER 1250-GAL SEPTIC TANK BOTTOM OF TRENCH: 5' BELOW GRADE FLOW LINE ELEVATION: 4.5' BELOW GRADE 600 GPD / 1.0 GPD/SF / 5' WIDE * 1.0 RED FACTOR [0.5' DEEP] = 120 LF TRENCH REQUIRED (120 LF SPECIFIED) GEOTEXTILE FABRIC 6" 5/1/25 5' 2' Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251128, Curtis Townsend, 05/08/25 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING DEPTH TO WATER AFTER MONITORING 0.07 11/14/24 1 2 3 4 5 6 GP Professional Engineers Stamp: HENKINS BLOCK 1 LOT 10 11/14/24 051-291-11 MIKE ANDERSON 1 0 16 1' OB 0:21 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: M Jakubisin 7 0 16 13' 11/21/24 COMMENTS: SITE PLAN 6 0 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED 5/1/25 MOISTURE NOTED AT TIME OF DIGGING?n/a 0:18 0:23 0:25 0:26 0:26 1 0 16 1 0 16 1 0 16 1 0 16 1 0 16 7 0 16 6 0 16 7 0 16 6 0 16 7 0 16 6 0 16 7 0 16 6 0 16 7 0 16 6 0 16 GM (SANDY) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251128, Curtis Townsend, 05/08/25