Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PELENOR BLK 1 LT 9
Lot 9 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www,muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP251143 Work Type: WellSeptic Initial Tax Code Number: 06032147000 Site Legal Address: PELENOR BLK 1 LT 9 G:0254 Site Mailing Address: Owner: WILKENS JACOB & LINDSEY Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 5/16/2025 5/16/2026 43615 Q Disposal Field © Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing G05_ 2 V is i:�D 0 F-5 / A/ Received By: - C, Date: _ Issued By: Date: Z- 5r 3 ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 060-321-47 Property owner(s) Jocob & Lindsey Wilkens Day phone (907) 980-0731 Mailing address 8904 Northwood Park Cir, Anchorage, AK 9951 Site address NHN Bernard Dr Legal description Pelenor Block 1 Lot 9 Number of Bedrooms 3 Engineering Firm Forge Engineering Building Permit Number Not Applicable FNI APPLICATION IS FOR: APPLICATION IS AN: (Z all that apply) Absorption Field 0 Initial El Septic Tank 0 Upgrade ❑ Holding Tank ❑ Renewal ❑ Privy ❑ Well THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: C'n () Permit/Rush Fees: 0 f% Waiver Fees: Date of Payment: . 013/i�S_ Date of Payment: Permit No. 0 S F()06( Si I Lf3 Waiver No. May 15, 2025 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Pelenor Block 1 Lot 9 Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 3 -bedroom home on the property. We are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes toward the road steeply near the center of the lot, but near the back the slopes are much milder. There is one area that is greater than 25%, but it is a short drop, only 5’. It is greater than 20’ away from the septic fields, per 15.65.210.B.1.e. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Please refer to the attached test hole logs, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251143, Curtis Townsend, 05/16/25 L[T2 NO IMPACT NO|MPACT PROPOSED WELL _ |-/ \ /---------- ���N«��F� ����|\/� __-. -_ .��_ DRIVE -__ 3-BDRM HOME LOT 3 UNDEVELOPED _ rC,v�����"," � =""_""L"=,..^ =.~F MT `- -x _— = _ ." ABSORPTION ^°ENCn .SEPTIC PLAN O 50 100 LOT 4 NO|MPACT LOT NO|M-- LEGEND CO-CLEANOUT 2CU-DOUBLE CLEANOUT FCO-FOUNDATION CLEAN{ FS-FLOWSPLOTERVALVE MH'MANHOLE MT'MONITORING TUBE GV-SEPT|CVENT TH-TESTHDLE PELENOR , BLOCK 1 LOT 9 DESIGN FACTORS: SYSTEM REQUIREMENTS: 450 GPD PEAK FLOW PERK RATE: 0.33 MIN/IN APPLICATION RATE: 1.0 GPD/SF 5'WIDE TRENCH SYSTEM 1000-GAL SEPTIC TANK 450 GPD / 1.0 GPD/SF / 5'WIDE * 1.0 RED FACTOR [0.5 DEEP]= 90 LF TRENCH REQUIRED (100 LF SPECIFIED) BOTTOM OF TRENCH: 6.0'BELOW GRADE FLOW LINE ELEVATION: 5.5'BELOW GRADE BOTTOM OF SAND: 8.0'BELOW GRADE 5' 6" T 6" 2' PROVIDE ADDITIONAL 6" FILL TO ACCOUNT FOR SETTLEMENT GEOTEXTILE FABRIC 4" PERFORATED PVC DRAINFIELD ROCK - ------- --- MOA APPROVED SAND 51 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3'OF COVER OVER TRENCHES AND 4'OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY 1W ii� 49 7H .......... .......... BenjanwSchiller CE 12592 ,s,o .5/ 3/25 AV PRO. DEPTH (feet) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 C -O A- .- SOILS LOG AND PERCOLATION TEST E N G I N E E R I N G LEGAL DESCRIPTION: PELENOR BLOCK1 LOT 9 PERFORMED FOR: LAST FRONTIER CONSTRUCTION DATE: 4/11 /25 PARCEL ID#: 060-321-47 TEST HOLE 1 !i_Iili'I11OB GM (SILTY SANDY GRAVEL) PERC TEST LOCATION GM (SILTY SANDY GRAVEL, COBBLES INCREASING WITH DEPTH) YES MOISTURE NOTED AT TIME OF DIGGING? 13 ' DEPTH TO WATER AFTER MONITORING 4/18/25 DATE OF MONITORING DATE READING NET TIME (MINUTES) DEPTH TOWATERNET (INCHES) DROP (INCHES) 4/11/25 1 2 15916 165 s 6 2 2 1596 16516 6 3 2 159 s 16516 6 4 2 15916 16516 6 5 2 15916 16516 6 6 2 159 -s 16516 6 PERCOLATION RATE: 0.3 (MIN/INCH) COMMENTS: USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED SITE PLAN TECHNICIAN: JARED EARLS