Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SOUTH ADDITION BLK 40A LTS 1 & 2 E2
SOUTH ADDITION Lot 1 & 2 E2 02-153-47 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP251147 Work Type: Septic Upgrade Tax Code Number: 00215347000 Site Legal Address: SOUTH ADDITION BLK 40A LTS 1 & 2 E2 G:1430 Site Mailing Address: 1512 D ST, Anchorage Owner: WOLF LAURIE BETH Design Engineer: FIRST WATER CONSULTING This permit is for the construction of: Effective Date: Expiration Date Lot Size in Sq Ft: Total Bedrooms: "te11r .S J' �Y I)epartIn ent 5/16/2025 5/16/2026 7000 Q Disposal Field 2 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 3 Special Provisions: This is an emergency tank and field permit application. The application is not complete. These provisions summarize what is to be submitted still. If the assumptions the design was based on are discovered to be incorrect, a change order is to be sought from the department and work is to cease until change order is approved. 1. 7 day groundwater monitoring is required. Construction may proceed at your own risk before the 7 day water monitoring is complete. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. 2. This design is based on the assumption that the soil is not GW or GP. If the results of the sieve analysis show otherwise, a change order will be required. ,---- S- i / V1*_ /,I w4L7 S s 0,-La ``"t �/=.o 3. The inspection report is to show a replacement subsurface disposal field according to 15.65.210 B. 4. Provide new survey as built as soon as it is completed. f s Received By: V ,_ Date: Issued By: Date: l S / MUNICIPALITY OF ANCHORAGE A/ Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section ON -SITE SEPTICMELL PERMIT APPLICATION Parcel I.D. 002-153-47 Property owner(s) LAURIE BETH WOLF Day phone Mailing address 1504 D STREET, ANCHORAGE, AK 99501 Site address 1504 D STREET, ANCHORAGE, AK 99501 Legal description SOUTH ADDITION BLOCK 40A LOTS 1 & 2 E2 Number of Bedrooms 3 Engineering Firm FIRST WATER CONSULTING Building Permit Number APPLICATION IS FOR: (Z all that apply) Absorption Field I -XI Septic Tank RX Holding Tank R Privy R Well R Not Applicable FN APPLICATION IS AN: Initial RX Upgrade EJ Renewal n THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: Permit/Rush Fees: Waiver Fees: Date of Payment: "ZO '- 5 Date of Payment: Permit No. L) Waiver No. 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / firstwaterAK@gmail.com ! !! May 16, 2025 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: NEW SEPTIC SYSTEM PERMIT LEGAL: SOUTH ADDITION BLOCK 40A, LOTS 1 & 2 E2 The existing sewer line crosses property line goes under the adjacent house and to the main. It has been verified the line has been crushed and non-functioning & per AWWU the property cannot be connected to sewer. Therefore, the property owner has requested we obtain a new septic permit for the above referenced lot. This is an emergency since the owner’s cannot use the facilities and are having to use a temporary porta potty & we request permit issuance ASAP. Attached is the not to scale as-built survey and one is being completed. We are also in the process of ground water monitoring & a sieve analysis is pending. We propose to install a 1500- gallon tank for current use and future flexibility (i.e. – An Advantex AX20 Pod if needed) and a shallow trench to serve the 3 -bedroom residence. The design is based on the attached test hole conducted this week. Groundwater was observed at 2-day monitoring & we’ll be measured 7+ days before any absorption field install. The property and area are served by public water as noted on the design. The slopes are flat at the proposed upgrade location. The design will not impact any of the neighboring properties. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251147, Curtis Townsend, 05/16/25 DESIGN JBR X 150 QPD = 450 GPD 450 GPD .D GPD/8F = 450 SF SAS 450 8F / 5 x .54RF (3.5'ED) = 49 F[ TRENCH USE ONE TRENCH — 49'(L) X 5'(0) X 3.5'(ED) TOTAL MAX DEPTH FROM EXISTING GRADE: —5' NOSLOPES >25%WITHIN 5IOFPROPOSED FIELD. STAKE PROPERTY LINES, WATER LINE, ESIVITG. OROTHER SEPAR/T|ON3...PRIOR TDCONST. . ___--- __" ISTH AVE | -----' v� STAKE WATER LOTTO CONST. LM FLAT E ' ------ CONNECTED- To INSTN7 Ll �M'iK�E SUrM TAW ' «oto | une FLAT FLAT Li MT FLAT FLAT FLAT FLAT | BLOCK ^v^ LOT 3 | | � BLOCK 40A LOT 4 ' v ' | | -----' ------ ------ ------- ------ DESIGN BASED FROM JKD HAND —DRAWN, DIGITIZED ASB NEW ASB PENDING. OF AZ4i�VA PREPARED FOR: LAURIE BETH WOLF F 5 1504 D STREET '.4 U* �% 74. sIl > 9 TH FIRST WATER CONSULTING ti ANCHORAGE, AK 99516 SCALE: 1" = 40' 1 X e..w DESIGN DETAILS: c<L3 4 3- INSTALL NEW 1500—GAL HDPE DEEP —BURIAL STEP SEPTIC TANK & ANCHOR IF NEEDED. MAINTAIN 10'+ FROM FOUNDATION, 200' TO WELLS, 5' TO FIELD & DECK SUPPORTS, 10' TO WATER SERVICE LINE, WITH 4' OF COVER OR INSULATION. INSTALL ONE 491 x 5'W x 3.5'ED TRENCHES —5' FROM GRADE w/ INSULATION & 2'+ OF COVER MAINTAINING 200' TO WELLS, 100' SURFACE WATER, 10' TO LOT LINE, 100' TO SEWER MHs.... INSTALL PER AMC 15.65, 15.55, & MASS...TANK BEDDING, SEPARATIONS, MATERIALS, — STAKE ALL SEPARATIONS BY A PROFESSIONAL SURVEYOR PRIOR TO INSTALL. — MUST STAKE — (PROPERTY LINES, ETC...) 0 m Wj LOT 1 Z Ra PREVIOUSLY CONNECTED TO SEWER o W cs LOT 2 FLAT 0 10'- NO WELLS WITHIN 200' OF PROPOSED SEPTIC TANK OR EXISTING FIELDS. FLAT 15TH AVE CATII RESERVE 313R X 150 GPD = 450 GPD 450 SPD/4 GPD/SF = 150 SF SAS ZD 150 3F / 5 x .54RF (3.5'ED) = 17 FT. TRENCH cn USE DNE TRENCH — 20'(L) X 5'(W) X 3.5'(ED) TOT& MAX DEPTH FROM EXISTING GRADE: —5' N90.00'00'E 70.00' 30' o 0 L0 STAKE WATER LINE PRIOR TO CONST. g APPROx. LOCI VA X FLAT E j LOT 1 1 Uc 0 i INSTALL NEW E 1500—GAL HDPE LOT 2 DEEP —BURIAL STEP • SEPTIC TANK. CATIII RESERVE ° -10'- FLAT MT FLAT 0 TH25-1 I FLAT WE 70,00' FLAT FLAT 30' APPROx SEWER MH. STAKE PRIOR TO CONST & MAINTAIN 100'+ FIRST \ I ASSEMBLY OF GOD MHO BLOCK 40A LOT 3 I � o MH BLOCK 40A LOT 4 SOUTH ADDITION B40A, LOTS 1 & 2 E2 SUPPORTISERVICES: I± OF AZ -4 LAUR EREPARBET WOLF ED /����,, 1504 D STREET * 9 TH* CHUGIAK, AK 99567 FIRST WATER CONSULTING uk��iilII DATE: 5/20/2025 ` tis Huffman ,x SURVEY. JKD , CIE 128991 13030 SUES WAY DRAWN: FWCS , o5/20/25 ANCHORAGE, AK 99516 SCALE: 1" = 30' , /20/ 5 ,�► 907-350-9566 FirstWaterAK©gmail.com PAGE: 2 OF 2 Flsl Wafer C O N S t1 L T I N C 3030 Sues Way - Anchorage, Alaska 99516 Tel.907-350-9566 FirstWaterAKkgmail.com SOILS LOG -PERCOLATION TEST LEGAL: SOUTH ADD B40A LOTS 1 & 2 E2 DEPTH FEET OG SOILS 1 ORG/OL 2 3 S W/sp-gp 4 5 6 GRAB SAMPLE 7 8 9 10 ML/SM - BLUE 11 12 13 >' BOH 14 15 16 17 18 19 20 OF A is TH - ....•:.` .. ... ......... Curtis Huffman CE 128991�r/ PERFORMED FOR: LAURIE BETH WOLF TESTHOLE # 25-1 DATE PERFORMED: 5/13/25 GROUNDWATER ENCOUNTERED: NO IF YES, AT WHAT DEPTH: NA DEPTH TO WATER AT MONITORING: 9' DATE: 5/20/2025 SEE SITE PLAN FOR SLOPE & LOCATION COMMENTS: VERY RAPID PERCOLATING SOILS — SEE SIEVE SP/SM INSITU MATERIAL SUITABLE FOR SYSTEM. VERIFY GROUNDWATER MT AT TIME OF CONSTRUCTION Reading Date Gross Time Net Time Depth to Water Net Drop 05/14/25 2 min 6" 6" " 6" 6" " 6" 6" PERCOLATION RATE <1 (MIN / INCH) TEST RUN BETWEEN 3 & 4 FT PERC HOLE DIAMETER 6" PRE-SOAKED PRIOR TO TEST & ALL READINGS TO THE 1/16Tx PERFORMED BY: FWC - I CURTIS HUFFMAN CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 05/20/2025 Northern Geotechnical Engineering, Inc. - Terra Firma Testing 11301 Olive Lane, Anchorage, Alaska 99515 Phone: (907) 344-5934 1 www.nge-tft.com Client: First Water Consulting Services Project: 7311-25 2025 Material Testing Report No: MAT:25-109-1 Issue No: 1 C 'r' - Material Test Report Reviewed By: Sean Totzke, MOA #: 076 / ICC #: 5310982 Date: 5/19/2025 The testing services reported herein have been performed to recognized industry standards and relate only to the items inspected. Unless otherwise noted, no other warranty is made. Should engineering interpretation be required, NGE-TFT will provide upon written request. This report shall not be reproduced in full, without the prior written approval of NGE-TFT. Sample Details Sample Description: Sample ID 25-109-1 Date Sampled 5/14/2025 Material Soil Sampling Method Grab Location Lots 1 & 2, Blk 40A, E2 Atterberg Limit: Liquid Limit: No10h11111* Plastic Limit: NPIN-PInkl Plasticity Index: NPlN011'11111) Linear Shrinkage Grading: ASTM C136 Particle Size Distribution Drying By: Oven Date Tested: 5/16/2025 Diameter Tested By: Rebecca Pineyro 600 200 100 60 20 6 2 600 200 100 50 mm Pm 100 Sieve Size % Passing Limits I In 100 90 3in } i f i 1100 1'/zin 00 80 [ a I 3/ <in 99 i t '/tin 94 N 70 Y r € 1 ;.. _i.. 92 E I %inn 89 a 60 No.4 87 s No.10 85 a 50 _! ! __ s _ ; , i f _ - No.20 82 ' No.40 74 40 1 i i .. - No.60 42 4 No.100 17 U a30 __i i I ; _ � i !- i _ l � } _ , � € -- No.200 4.8 r 20_- t 10 i t 44 s :, f (.. . j Sieve Size 6" 3" 3/4" 1/4" #10 #20 #60 #200 11/2" 1/2" #4 #40 #100 BOULDERS COBBLES GRAVEL (13%) SAND (82%) SILT/CLAY COARSE 1 FINE COARSE MEDIUM FINE D85: 2.3218 D60: 0.3375 D50: 0.2858 0% 0% 1.5% 11.3% 2.7% 10.7% 1 69.1% 5% D30:0.1956 D15: 0.1336 D10: 0.1007 Cu:3.35 Cc: 1.13 Form No: 18909, Report No: MAT:25-109-1 © 2000-2025 QESTLab by SpectraQESTcom Page 1 of 2 Northern Geotechnical Engineering, Inc. - Report No: MAT:25-109-1 Terra Firma Testing t �, Issue No: 1 11301 Olive Lane, Anchorage, Alaska 99515 Phone: (907) 344-5934 1 www.nge-tft.com Client: First Water Consulting Services Project: 7311-25 2025 Material Testing Material Test Report Reviewed By: Sean Totzke, MOA #: 076 / ICC #: 5310982 Date: 5/19/2025 The testing services reported herein have been performed to recognized industry standards and relate only to the items inspected. Unless otherwise noted, no other warranty is made. Should engineering interpretation be required, NGE-TFT will provide upon written request. This report shall not be reproduced in full, without the prior written approval of NGE-TFT, Sample Details Sample ID 25-109-1 Date Sampled 5/14/2025 Material Soil Sampling Method Grab Location Lots 1 & 2, Blk 40A, E2 Other Test Results Description Method Result Limits Cu ASTM D2487 3.35 Cc 1.13 FM ASTM C136 Procedure ASTM C117 A Water Content (%) ASTM D2216 6.1 Date Tested 5/15/2025 Tested By Jacob Marvin Group Code ASTM D2487 SP-SM _ Group Name Poorly graded sand with silt Tested By Nic Cropper Date Tested 5/16/2025 Liquid Limit ASTM D4318 Not Obtainable Plastic Limit NP (Non -Plastic) Plasticity Index NP (Non -Plastic) Tested By Nic Cropper Date Tested 5/16/2025 Comments N/A Form No: 18909, Report No: MAT:25-109-1 © 2000-2025 QESTLab by SpectraQESTCOm pans 9 of 9 Y EASEMENTS OF RECORD, OTHEFT ".�,►„� Dowring�� THOSE SHOWN ON THE RECORDEMata _ PLAT, ARE NOT SHOWN HEREdt4l, a ork shall be done as shown ori'a �s� ..'0 "r plot plan. Approved plans and spec�-�Pox;sslal�l•L�� uulLlrations shall not be changed, modifierl � ;r altered without first obtaining a valir' —LOT EY CERTI F 1 CAT I C'Vxx>�xxxxxx 9cxx=xX SOUIU ADDITION TO THE ORIGINAL TOWNSITE ANCHORAGE. RECORDING DISTRICT PARED BY: UOWLINV -tip-XbbVU1Ai e- `:: -804 EQS.T .'15th Ave. .Suite 2 AAIrNnRAr.17 Al AcleA aC]>;nl LEGERD: AUGBMITTAL z s 2002 BRASS CAP NORU4ENT O HIM PIPE 91 STEEL Piz! 0 SURVEY HUB & TACK Res I dell c e of