HomeMy WebLinkAboutHENKINS BLK 1 LT 9HENKINS
Lot 9
051 - 292 - 17
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
hftp://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP251190
Work Type: WellSeptic Initial
Tax Code Number: 05129217000
Site Legal Address: HENKINS BLK 1 LT 9 G:0755
Site Mailing Address: 16035 OLD GLENN HWY, Chugiak
Owner: MIDNIGHT SUN CONSTRUCTION LLC
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Effective Date
Expiration Date
Snr
r.
n
I)e1mrtMelit
Lot Size in Sq Ft:
Total Bedrooms:
6/12/2025
6/12/2026
20038
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy 2 Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: Date:
Issued By: _ Date: I/ ��
3
ON -SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 051-292-17
Property owners) Midnight Sun Construction LLC Day phone (907)727-1433
Mailina address PO Box 210994, Anchorage, AK 99521
Site address 16035 Old Glen Hwy
Legal description Henkins7 Block 1 Lot 9
Number of Bedrooms 3
Engineering Firm Forge Engineering
Building Permit Number
Not Applicable ❑
APPLICATION IS FOR: APPLICATION IS AN:
(Z all that apply)
Disposal Field
ED Initial F-1
Septic Tank
ED Upgrade El
Holding Tank
❑ Renewal El
Privy
❑
Well
Fx]
Water Storage
0
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Permit/Rush Fees: �q V 0
Date of Payment: L o. /a' —
Permit No. O.S 2a 51 tq 0
Waiver Fees:
Date of Payment:
Waiver No.
Distance:
May 2025
June 2, 2025
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Henkins, Block 1 Lot 9 – Old Glen Hwy
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot intends to build a 3-bedroom home on the property, so we are
submitting this permit application for the construction of a new well and septic system. The
attached site plan identifies the location of the home as well as the proposed well, septic location
and alternate site. No conflicts exist between this proposed system and any other well or septic
system, whether on this lot or adjacent lots.
The ground surface on the lot has a drop off down from the proposed house to the septic system.
There is a moderate slope of around 10% where the proposed system will be located. There are no
slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours
are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not
impact this septic system. The new trench will be constructed parallel to the slope as much as
possible.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all
wells and surface water, and more than 5’ away from the septic tank. The alternate site is located
more than 6’ away.
Please refer to the attached test hole logs, plan and profile pages for the septic design. If this design
is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251190, Curtis Townsend, 06/12/25
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
1"=40'
LOCATE NEIGHBORING SEPTIC SYSTEMS
BY SURVEY AND ENSURE 100' SEPARATION
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
TH#1
HENKINS, BLOCK 1 LOT 9
FEET
0 40 80
SEPTIC PLAN
5/28/25
GI
L
B
E
R
T
R
O
A
D
OL
D
G
L
E
N
N
HIG
H
W
A
Y
PROPOSED WELL
EXISTING WELL
100' WELL RADIUS
505
510
515
520
525
(2) 60' LONG X 5' WIDE, 0.5'
EFFECTIVE DEPTH TRENCHES
1250-GAL STEP TANK
MT
MT
MT
MT
FCOVACANT
VACANT
VACANT
VACANT
ALTERNATE SITE CAT III, 5' WIDE X
20' LONG, 0.5' EFFECTIVE DEPTH
3-BDRM HOME
EXISTING SEPTIC
EXISTING SEPTIC, LOCATION
APPROXIMATED
LOCATE NEIGHBORING SEPTIC SYSTEMS BY SURVEY
AND ENSURE 100' SEPARATION
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251190, Curtis Townsend, 06/12/25
HENKINS, BLOCK 1 LOT 9
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
DRAINFIELD ROCK
DESIGN FACTORS:SYSTEM REQUIREMENTS:
450 GPD PEAK FLOW
PERK RATE: 7.5 MIN/IN
APPLICATION RATE: 0.8 GPD/SF
5' WIDE TRENCH SYSTEM
1250-GAL STEP TANK
BOTTOM OF TRENCH: AT GRADE
FLOW LINE ELEVATION: 0.5' ABOVE GRADE
450 GPD / 0.8 GPD/SF / 5' WIDE * 1.0 RED FACTOR [0.5' DEEP] = 112.5 LF TRENCH REQUIRED
(120 LF SPECIFIED)
11
4" PVC w/ 1
8" ORIFICES
EVENLY SPACED @ 6.0' OC
5/30/25
PROVIDE 6" TOPSOIL AND GRASS
SEED
5'
2'
6"
2'
6"
MOA APPROVED SAND
GEOTEXTILE FABRIC
AND 2" INSULATION
MAXIMUM 3:1 SLOPE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251190, Curtis Townsend, 06/12/25
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
DEPTH
(feet)
TEST HOLE 1
SC (SILTY SAND w/ POCKETS OF
CLAY AND SOME COBBLES)
Professional Engineers Stamp:
HENKINS B1 L9
5/21/25 051-292-17
MIDNIGHT SUN CONSTRUCTION LLC
OB
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
PERC TEST LOCATION
TECHNICIAN: JUSTIN EARLS
COMMENTS:
SITE PLAN
USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED
5/28/25
SM (SANDY SILT w/ SOME
GRAVEL)
DATE READING NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERCOLATION RATE: (MIN/INCH)
(inches)(inches)
7.5
5/21/25 1
2
3
4
5
6
330 7 2
16 4 2
16
3
3
30
30
7
47
4
DATE OF MONITORING
DEPTH TO WATER AFTER MONITORING4'
5/28/25
MOISTURE NOTED AT TIME OF DIGGING?YES
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251190, Curtis Townsend, 06/12/25