Loading...
HomeMy WebLinkAboutCANYON VIEW ESTATES BLK 1 LT 7WUILi7lf ESTATES Block 1 Lot 7 021 -021 -40 (Rev 05/0211 Municipality of Anchorage On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 1 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP251213 PID Number: 021-021-40 Dwelling: nN Single Family (SF) El with ADU n Duplex (D) n Two Single Family Project: nE New n Upgrade Name Hultquist Homes, Inc. ABSORPTION FIELD ❑ Deep Trench nN Wide Trench n Bed n Mound Site Address 13783 Canyon Road El Other Phone Bedrooms Soil Rating Total depth from original grade 4 0.8 GPD/SF� 1.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 0.5 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Canyon View Estates 1 7 Fill added above original grade 2.3-7.4 Ft. Gravel length 2@75 Ft. Township Range Section Gravel -width 5.0 Ft. Beds: Number of Lines n/a Distance between lines n/a Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 750 Ft2 2 8.1 Ft. Well 100'+ 100'+ 100'+ NA 25'+ TANK El Septic 9 S.T.E.P. El Holding F1 Other Manufacturer Anchorage Tank Capacity 1500 Gal. Surface Water 100'+ 100'+ 100'+ NA Material Number of compartments Lot Line 5'+ 10'+ 10'+ NA NA Steel (Epoxy Coated) 2 Foundation 10'+ 10,+ 10,+ NA LIFT STATION Manufacturer Capacity Remarks Orenco 250 Gal. Alarm location House Electrical installed by Tesla Electric PIPE MATERIAL House to tank F628 drainfiTank to eld D1785 Installer Hultquist Homes, Inc. Drainfield D1785 CO/MT F628/D3034 inspector PES BENCHMARK (Assumed elevation) 1194.1 ft Inspdates:ection im 10/17/25 10/20/25 Location and description 3rd 10/23/25 2nd 4111 11/13/25 See Site Plan, Bottom of window trim ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp --%-- _,w 21�11kk C? A4_1 kkII Conditional Approval: Date -- - ----- -- T 49 TH t ever) R. Pannone W CE 8 1 �9; . - ", Q,- ,w 1(, - . <� 11 AW 0o- -Q1/13/2026 Septic Systevir'__ Approved lox Date ik�, IeOFES9 this approval does not include well permit require encs. ents (Rev 05/0211 Lot 6 Lot 7 Lot 8 CA N Y O N R O A D PU B L I C U S E E A S E M E N T WELL (N) (APPROX. LOCATION) TH-1 (PES) PU E 2 0 1 6 - 0 1 3 1 0 2 - 0 20' T & E E A S E M E N T 24.4 77.8 109.4 PAVED DRIVE TH-2 (PES) 4 BR SFD (N) WELL (E) 103.7 10.3 ASSUMED PATH WATER SERVICE LINE (E) DR I V E W A Y ±15% ±15% ±15% 1180 1220 1175 1185 1190 1195 1200 111.5 8.1 6.0 WELL (E) APPROX. MOA MAPPED VEGETATED DRAINAGE WAY THIS AREA TH-8 RESERVE AREA (P) (CAT III NIC) INSTALLED 1500gal STEP TANK (N) W/ORENCO PF300511 EFFLUENT PUMP INSTALLED FC BEFORE TANK 1.25'' Ø SCH 40 PVC DISCHARGE LINE TO ABSORPTION FIELDS (N) B A FC MH1 MH2 MT1 MT2 MT3 MT4 INSTALLED DRAIN FIELD (N) (2ea) 75LF x 5.0'W x 0.5'E.D. x 1.0'T.D. REMOVED 2'± OF ORGANICS BELOW FIELDS REPLACED W/FILTER SAND & LEVELED USED 1.25''Ø SCH 40 PVC LATERALS W/ 1/8'' HOLES @ 3.75' (45") O.C. (20 EVENLY SPACED HOLES) HOLES ORIENTED DOWN. INSTALLED MT AT EACH END BM 22.9± PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) LJ C RE C O R D D R A W I N G CA N Y O N V I E W E S T A T E S , B L O C K 1 , L O T 7 CL I E N T : H U L T Q U I S T H O M E S I N C . SI T E : 1 3 7 8 3 C A N Y O N R O A D AN C H O R A G E , A K 01 / 1 3 / 2 0 2 6 02 1 - 0 2 1 - 4 0 OS P 2 5 1 2 1 3 AC P ST E V E N R . P A N N O N E CE - 8 1 4 9 R E G I STEREDPROFES S I O N A L E N GINEER 01 / 1 3 / 2 0 2 6 SI T E P L A N 1" = 6 0 ' 1 O F 2 A B FC 18.2 14.7 MH1 37.9 25.4 MH2 46.8 33.5 MT1 72.2 48.7 MT2 68.1 53.1 MT3 145.5 124.5 MT4 143.5 125.8 RECORD DRAWING THIS RECORD DRAWING REPRESENTS THE AS-BUILT CONDITION OF THE PROPERTY IMPROVEMENTS DESCRIBED ABOVE. THE DRAWING AND ANY OTHER SUBSEQUENT ATTACHED OR INCLUDED INFORMATION IS BASED ON PERIODIC VISUAL OBSERVATION BY A REPRESENTATIVE OF PES ALONG WITH NOTES, PHOTOS, AND OTHER INFORMATION PROVIDED BY THE INSTALLER OF THE SYSTEM. THE INFORMATION PROVIDED IN THE RECORD DRAWING APPEARS REASONABLE AND REPRESENTS THAT THE PROJECT WAS DESIGNED AND CONSTRUCTED IN GENERAL CONFORMANCE OF 18 AAC 72, THE ADEC ONSITE WASTEWATER SYSTEM INSTALLATION MANUAL, AND AMC 15.65 WHERE APPLICABLE. PES SHALL NOT BE HELD LIABLE FOR SYSTEM DEFICIENCIES WHICH FALL OUTSIDE THE SCOPE OF THE REQUIRED VISUAL OBSERVATIONS OR SUBSEQUENT OBSERVATIONS IF REQUESTED BY THE INSTALLER. SEPTIC SYSTEM INSTALLERS ARE TRAINED AND APPROVED BY THE MUNICIPALITY OF ANCHORAGE AND OR ADEC AS APPLICABLE. INSTALLERS ARE RESPONSIBLE FOR CONSTRUCTING THE SEPTIC SYSTEM AS DESIGNED AND ENSURING THEIR WORK CONFORMS TO THE CODES AND POLICIES STATED ABOVE. DESIGN PARAMETERS PRIMARY SEPTIC SYSTEM NO. BEDROOM: 4(600 gpd) TANK SIZE: 1500gal MIN. (STEP) PERC RATE: 9.6 MPI SOIL RATING: 0.8 GPD/SF AREA RQD: 750 SF SYS. TYPE: WIDE TRENCH 0.5' E.D. MIN LENGTH: 150 LF USED: (2EA) 75LF x 5.0'W x 0.5'E.D x 1.0'T.D. TOTAL AREA: 750 SF RESERVE SEPTIC SYSTEM NO.BEDROOM: 4(600 gpd) TANK SIZE: 1500gal W/ CAT III TREATMENT PERC RATE: 9.6 MPI SOIL RATING: 5.0 GPD/SF AREA RQD: 120 SF SYS.TYPE: WIDE TRENCH 0.5' E.D. MIN LENGTH: 24 LF USE: 24LF x 5.0'W x 0.5'E.D x 2.0'T.D. TOTAL AREA: 120 SF *MEASUREMENTS ARE ± 1.0' SHEET NOTES: 1.PER CONTRACTOR - ADDITION OF TOP SOIL AND SEEDING OF MOUNDED FIELDS TO OCCUR IN SPRING OF 2026. ABBREVIATIONS CO CLEAN OUT NO. DCO DOUBLE CLEANOUT DV DIVERTER VALVE (E)EXISTING FC FOUNDATION CLEANOUT MT MONITOR TUBE NO. MH MANHOLE NO. (N)NEW NIC NOT IN CONTRACT (P)PROPOSED TH TEST HOLE TYP TYPICAL STREAM/DRAINAGE WAY CENTERLINE FLOW PATH NEW SEPTIC WATER LINE / WELL RADIUS ESMT/SETBACK FC MH1 MT1 1500gal EPOXY STEEL STEP OG SOUTH: 1190.0 0.5' DRAIN ROCK 12 8 11 10 9 6 7 5 3 4 2 TH-1 ELEV: ~1191.5± OR/PT1 BOH SM GM/SM MH2 OG NORTH: 1192.0 12 8 11 10 9 6 7 5 3 4 2 TH-2 ELEV: ~1193.8± OR/PT1 BOH GM GM/ML MT3 2.0 2.0 MT2 OG SOUTH: 1191.5 0.5' DRAIN ROCK OG NORTH: 1194.0 MT4 2.0 2.0 1184.2 FG SOUTH: 1197.2 1179.5 INV: 1191.5 FG NORTH: 1195.7 INV: 1191.5 1181.8 FG: 1189.9 FG:1190.8 OG: 1190.5 DRAIN ROCK 6" ABOVE PIPE INV 1.25"Ø SCH 40 PVC W/ 1 8'' DRAIN HOLES 3.75' O.C. FILTER FABRIC BOX: 1188.0 BOX: 1190.0 TOP OF SAND: 1191.0TOP OF SAND: 1191.0 FG SOUTH: 1198.9 INV: 1193.5 FG NORTH: 1196.3 INV: 1193.5 DRAIN ROCK 6" ABOVE PIPE INV 1.25"Ø SCH 40 PVC W/ 1 8'' DRAIN HOLES 3.75' O.C. FILTER FABRIC BOX: 1189.5 BOX: 1192.0 TOP OF SAND: 1193.0TOP OF SAND: 1193.0 WEST TRENCH EAST TRENCH TEST HOLES PERFORMED: 04/03/2025 WATER @ 6.75' (TH-1): 06/24/2025 WATER @ 6.0' (TH-2): 06/24/2025 3:1 3:1 3:1 3:1 NOTE: TOP SOIL AND SEEDING OF LEACH FIELD MOUNDS TO OCCUR IN SPRING 2026 PER SUBJECT INSTALLER. PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) LJ C RE C O R D D R A W I N G CA N Y O N V I E W E S T A T E S , B L O C K 1 , L O T 7 CL I E N T : H U L T Q U I S T H O M E S I N C . SI T E : 1 3 7 8 3 C A N Y O N R O A D AN C H O R A G E , A K 01 / 1 3 / 2 0 2 6 02 1 - 0 2 1 - 4 0 OS P 2 5 1 2 1 3 AC P ST E V E N R . P A N N O N E CE - 8 1 4 9 R E G I STEREDPROFES S I O N A L E N GINEER 01 / 1 3 / 2 0 2 6 PR O F I L E NT S 2 O F 2 I SCALE: NTS SEPTIC SYSTEM PROFILE www.sullivanwaterwells.com Pump Installation Log Well Drilling Permit Number: OSP 251213 Date of Issue 6/30/25 Parcel Identification Number: 0210214000 Legal Description Property Owner Name & Address Canyon View Estates Block 1 Lot 7 Hultquist Homes Pump Installation Date: 8/4/25 Pump Intake Depth Below Top of Well Casing: 350 feet Pump manufacturer’s Name: Grundfos Pump Model: 10SQE15-330 Pump Size: 1.5 hp Pitless Adapter Burial Depth: 10 feet Pitless Adapter Installer: Pitless Manufacturer: Unknown Disinfected Upon Completion? yes no Method of Disinfection: Chlorine 50 PPM Comments: Pump Installers Name: Sullivan Water Wells Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Merrill Certified Drilling Log OWNER OF LAND: Hultquist Homes ADDRESS: 13783 Canyon Rd. Anchorage, AK 99516 LEGAL DESCRIPTION Canyon View Estates Block 1 Lot 7 DATE: 7/3/25 PERMIT NUMBER: OSP251213 DATE OF ISSUE: 6/30/25 TAX IDENTIFICATION NUMBER 02102140000 Is well located at approved permit location: Yes No Method of Drilling: air rotary cable tool Depth of Well: 360’ Casing Type: Steel Wall thickness .250 inches Diameter: 6 inches, depth 56 feet Liner type Static Water Level: 58 feet Recovery Rate 2 gpm gph Method of Testing Air Well Intake Opening Type: open end open hole Screened Start feet Stopped Perforations Start feet Stopped Grout Type: Bentonite Volume: 50 lbs Depth: from 2 feet, to 42 feet Well Disinfected Upon Completion: yes no Method of Disinfection: Chlorine 50 PPM Comments: Bore Hole Data Depth From To 0 2 Casing Stickup 2 4 Overburden 4 14 Silty Sand & Gravel w/ Clay 14 53 Tight Silty Sand & Gravel 53 128 Bedrock Gray 128 136 Bedrock Brown 136 341 Bedrock Gray 341 357 Bedrock Brown 357 360 Bedrock Gray Hard Drillers Name: Cole Sullivan ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP251213 Work Type: WellSeptic Initial Tax Code Number: 02102140000 Site Legal Address: CANYON VIEW ESTATES BLK 1 LT 7 G:3042 Site Mailing Address: 13783 CANYON RD, Anchorage Owner: HULTQUIST HOMES INC Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 6/30/2025 6/30/2026 79050 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy 2 Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Date: r Issued By: Date: 4 ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 021-021-40 Property owner(s) Hultquist Homes Inc Day phone Mailing address 12570 Old Seward Highway Anchorage, AK Site address NHN Canyon Road Legal description Canyon View Estates 131 L7 Number of Bedrooms 4 Engineering Firm Pannone Engineering Services, LLC Building Permit Number V 9 Not Applicable El APPLICATION IS FOR: APPLICATION IS AN: (Z all that apply) Disposal Field 0 Initial El Septic Tank El Upgrade 1:1 Holding Tank El Renewal El Privy ❑ Well Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Permit/Rush Fees: 7X00 Date of Payment: (fi _? /01 Permit No. () s rq " 9� (9 L� May 2025 Waiver Fees: Date of Payment: Waiver No. Distance: Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, Alaska Subject: Canyon View Estates Block 1 Lot 7 Private Well and Septic System Permit Request This is a design narrative for a permit to install an initial well and septic system on the subject property. The system will serve a proposed four-bedroom (4) house. This lot and surrounding lots are served by private wells. 1. Soils: Two test holes were performed on this lot by Pannone Engineering Services, LLC on 04/03/2025. Groundwater was not observed during the excavation of these test holes, and bedrock was not encountered. Groundwater was observed in the test hole monitor tubes after 7-days at 6.75’ and 6.0’ BGS respectively. Based on the results of the percolation test and overall soils appearance an application rate of 0.80 gpd/SF was used for the design of a conventional wastewater treatment system in the area of the test holes. 2. Soil Absorption System Design: See design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. 4. Topography: See attached site plan for area topography. There are no slopes exceeding 25% less than 50ft from the proposed drain field. 5. Drawing Markings: The Drawings are marked “For MOA Review Only”. When written notification that the review is complete and no further comments are received from MoA On-Site Department, the note will be removed and “For Construction” drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions, please contact me at (907) 745-8200. Sincerely, SRP Steven R. Pannone, P.E. F. ASCE Owner/Civil Engineer 25 June 2025 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251213, Curtis Townsend, 06/30/25 PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) 06 / 3 0 / 2 0 2 5 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251213, Curtis Townsend, 06/30/25 PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) 06 / 3 0 / 2 0 2 5 COMMENTS: Test hole excavated by Hultquist Homes, Inc. PERFORMED BY: PANNONE ENGINEERING SERVICES, LLC. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. ·9.6 (min/inch) ·6" ·2 FT AND 3 FT · SOILS LOG & PERCOLATION TEST Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251213, Curtis Townsend, 06/30/25 PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) 06 / 3 0 / 2 0 2 5 COMMENTS: Test hole excavated by Hultquist Homes, Inc. PERFORMED BY: PANNONE ENGINEERING SERVICES, LLC. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. ·1.7 (min/inch) ·6" ·2 FT AND 3 FT · SOILS LOG & PERCOLATION TEST Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251213, Curtis Townsend, 06/30/25 PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) 06 / 3 0 / 2 0 2 5 INSTALL SYSTEM IN ACCORDANCE WITH THE ATTACHED DESIGN AND SPECIFICATIONS. 6.0 FEET 6.0 FEET Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251213, Curtis Townsend, 06/30/25 MUNICIPALITY OF ANCHORAGE Development Services Department x : r' Phone: (907)343-7904 On -Site Water & Wastewater Section Fax: (907)343-7997 Certificate of On -Site Systems Approval OSC261009 Parcel ID 021 -021-40 Expiration Date: 8/412026 Legal description CANYON VIEW ESTATES BLK 1 LT 7 Site address 13783 CANYON RD Current property owner(s) HULTQUIST HOMES INC X The On-site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or conditions: No comments Original Certificate Date 1/14/2026 This ificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject s em(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, evelopment Service Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's submittal. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Checklist_May2025.docx COSA Checklist Legal Description: Parcel ID: If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank Date of pumping Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D.DISPOSAL FIELD DATA Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Adequacy test date Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) in Effective depth used in Effective depth remaining in Comments/Deficiencies: E. SEPARATION DISTANCES From Well on Lot to: (Please enter distances if less than required) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Disposal Field on Lot > 100’ Yes if No ft Neighboring Disposal Fields > 100’ Yes if No ft Sewer Line/Main > 100’ Yes if No ft Sewer Manhole/Cleanout > 100’ Yes if No ft Sewer Service/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required) Tank to Foundation > 10’ Yes if No ft Field to Foundation > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main/Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F.ENGINEER’S COMMENTS G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER Phone Name of Firm Engineer’s Printed Name COSA Checklist_May2025.docx Date As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC & MOA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the years, and the water usage of the people served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail, and satisfactory test results do not guarantee future performance if the system, nor do they guarantee that there are no hidden defects of encroachments. Therefore, we cannot provide any warranty of future performance, nor can we estimate the remaining life of the system. The content of this report is for the sole benefit of the owner listed above. 1/13/26 Lot 7, Block 1, Canyon View Estates Subdivision Asbuilt Land Surveying Land Development Consultants Subdivision Specialists Construction Surveying AEC# 173042 S4 Group 610 E 5th Avenue Anchorage, Alaska 99501 (907) 306-8104 mail@S4AK.com 0 60' GRAPHIC SCALE 11/6/2025