HomeMy WebLinkAboutOVERLOOK ESTATES #3 LT 26ow.01mbers hk
LOT 26
067- 231 - 39
MUNICIPALITY of ANCHORAGE
Development Services DepartmentPhone; 907-343-7904
s
On -Site Water & Wastewater Section Fax: 907-3437997
Pump Installation Log
Well Drilling Permit Number: e�S/'� �/ZDate of Issue: 4/P- .�
Parcel Identification Nurnber:66? ? 3 -_"
Legal Description
Block
Lot
Property Owner Name & Address:
6;V -.5 -
isPump
Pump Installation Date: --- ��
�
Pump Intake Depth. Below Top of Well Casing; /-72feet
Pump Manufacturer's Name:.fa/rte//ice
Pump Model: li�%/'�s —_Z/ -'V2
Pump Size: hp
Pitless Adapter Burial Depth; feet
Pitless Adapter Manufacturer's Name:
Pitless Adapter Installer:
Well Disinfected Upon Com let' fl? , Yes ❑ No
Method of Disinfection: ftdG/r/Yz
Comments:
Pump Installer Name:
Company:
Mailing Address:
City: State;/"9//-Zip;
Zip;_�
Attention: The purnp installer shall provide a pump installation log to On-site within 30 days of pufnp installation.
(Rev 051o
)
Municipality of Anchorage
On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 3
ON-SITE
WASTEWATER INSPECTION REPORT
Permit Number: OSP251201
PID Number: 067-231-39
Dwelling: S Single Family (SF)
❑ with ADU M Duplex (D) R Two Single Family Project: RN New R Upgrade
Name
Kourosh Partow
ABSORPTION FIELD
R Deep Trench 9 Wide Trench El Bed R Mound
Site Address
27741 Wilde Cir
El Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
13
1.0 GPD/SF
4.7 / 4.4 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
4.2/3.9 Ft.
Gravel depth beneath pipe
0.5/0.5 Ft.
Subdivision
Block Lot
Overlook Estates #3
26
Fill added above original grade
0.0/0.0 Ft.
Gravel length
90.0 Ft.
Township Range Section
Gravel width
5.0 Ft.
Beds: Number of Lines
N/A
Distance between lines
N/A Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
2
Dist. between trenches
>6
From
Tank
Field
Tank
Line
450 Fe
Ft.
Well
>100'
>100'
N/A
N/A
>251
TANK 9 Septic E:1 S.T.E.P. El Holding El Other
Manufacturer
Greer
Capacity
1000 Gal.
Surface Water
>100'
> 100'
N/A
N/A
Material
Plastic 12
Number of compartments
Lot Line
>5'
>10'
N/A
N/A
NA
Foundation
>10'
>10'
N/A
N/A
LL:�TATION
Manufacturer
Capacity
Gal.
Remarks Deep -burial tank
Alarm location
Elects i talled by
PIPE MATERIAL House to tank D3034 dTankto rainfieldD3034
Installer
Whitters Excavation
Drainfield D3034 CO/MT D3034
Inspector Justin Earls
BENCH MARK (Assumed elevation) 100 ft
Inspection 15` 7/22/25
7/22/25
Location and description
dates:
2 nd
th
Bottom of siding SW corner
3m
4
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
N
F
Conditional Approval:
Date
4:0...
P J
AV, TH
.........
Benjan8chiller
Septic 3Y Ste
E
Approved
Dat IT
CE 12592
Aw
1•0/2•7•/25
,0 \P�dw
te: this approval does not include well permit requirement
klk�, 10ROFESS0W
(Rev 051o
)
Benjamin Schiller
CE 12592
R
E
G
ISTEREDPROFE S S I O N A L E N GINEER
1"=50'
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
PV - PUMP VAULT
LEGEND
PERMIT # OSP251201 PID # 067-231-39
OVERLOOK ESTATES #3, LOT 26
A B
FCO
MH 26.8
SV 28.4
2CO 31.3
CO1 52.6
MT1 54.1
CO2 66.4
10.2
21.6
25.5
29.5
56.5
57.2
66.1
FEET
0 50 100
PLAN AS-BUILT
11/21/25
15' UTILITY
E
A
S
E
M
E
N
T
WILDE CI
R
EA
G
L
E
R
I
V
E
R
R
O
A
D
PERMITTED SEPTIC SYSTEM
DOES NOT IMPACT PROPOSED
SYSTEM
UNDEVELOPED
EXISTING WELL
3-BDRM HOME
360
365
370
375
380
385
390
395
TH#1
ST
R
E
A
M
1000-GAL SEPTIC TANK
(2) 45' LONG X 5' WIDE, 0.5'
EFFECTIVE DEPTH TRENCHES FCO
2CO
CO4
CO3CO2
CO1 MT4
MT3
MT2
MT1
TH#2
MH
SV
MT2 68.0
CO3 63.4
MT3 61.4
CO4 52.1
MT4 50.1
67.2
46.7
44.8
34.7
32.8
A
B
100' STREAM SETBACK
PROFILE AS-BUILT
(NO SCALE)
94.5
90.2
95.0
99.0
FC
O
MH
SV
PERMIT # OSP251201 PID # 067-231-39
OVERLOOK EST #3, LOT 26
1000 GAL
SEPTIC TANK
2C
O
94.3
Benjamin Schiller
CE 12592
R
E
GISTEREDPROFE S S I O N A L E N GINEER
10/27/25
DRAINFIELD ROCK
MT
CO COMT
MOA APPROVED SAND
92.4
91.9
89.9
45'
MT
CO COMT
TH
#
2
NO GROUNDWATER 7/31/25
81.6
92.7
92.2
90.2
92.7
92.2
90.2
96.6 ORIGINAL AND FINISH GRADE
TH
#
2
NO GROUNDWATER 7/31/25
81.6
92.4
91.9
89.9
DRAINFIELD ROCK
MOA APPROVED SAND
NORTH TRENCH
SOUTH TRENCH
45'
96.6 ORIGINAL AND FINISH GRADE
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE:PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
DEPTH
(feet)
TEST HOLE 2
DATE READING NET TIME(minutes)
DEPTH toWATER NET DROP
PERCOLATION RATE: (MIN/INCH)
(inches)(inches)
DATE OF MONITORING
DEPTH TO WATER AFTER MONITORING
<1
6/6/25 1
2
3
4
5
6GW (SILTY SANDY GRAVEL)
Professional Engineers Stamp:
OVERLOOK ESTATES #3, LOT 26
7/22/25 067-231-39
KOUROSH PARTOW
159 8
16
FILL
0.1
Benjamin Schiller
CE 12592
R
E
GISTEREDPROFE S S I O N A L E N GINEER
PERC TEST LOCATION
TECHNICIAN:JUSTIN EARLS
165 8
16
NONE
7/31/25
COMMENTS:
SITE PLAN
6
USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED
10/27/25
MOISTURE NOTED AT TIME OF DIGGING?NO
159 8
160.1 165 8
16 6
159 8
160.1 165 8
16 6
159 8
160.1 165 8
16 6
159 8
160.1 165 8
16 6
159 8
160.1 165 8
16 6
OB
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Pax: 907-343-7997
Well Log
Permit Number: # OSP251201 Date of Issue: 6/30125 Parcel Identification Number: 067-231-39
Date Started: 7/2125 Date Completed: 7/21125 Is well located at approved permit location? Yes ❑■ No ❑
Legal Description: Overlook Estates #3 Lot 26, 27741 Wilde Circle, Eagle River, AK
Property Owner Name & Address: Eklutna, Inc.
16515 Centerfield Drive
Eagle River, AK
Borehole Data: Depth (ft)
Soil Type, Thickness & Water Strata From To
Method of Drilling X air rotary [] cable tool
Casing type: A53B steel
Wall Thickness: .25 inches
Diameter: 6 inches Depth: 80 feet
Liner Type:
Diameter: inches Depth: feet
Casing stickup above ground: 3 feet
Casing stick up
0
3
Silt - Gravel
3
21
Wet silt - Gravel
21
50
Water - Gravel
50
81
Static water level (from ground level): 47 feet
Pumping level: feet after
1 hours pumping 1gpm
Recovery Rate: _wpm
Method of Testing:
Well Intake Opening Type:
E] Open End ❑ Open Hole
❑ Screened Start feet Stopped feet
❑ Perforations Start feet Stopped feet
Grout Type: Bentomte Volume: 4 Bags
Depth: 78 Start 3 feet Stopped 81 feet
Well Disinfected Upon Completion? Yes No
Method of Disinfection: °"� "°T'b' Comments:
—
❑ ❑
Well Driller: KalebBean
Company: E & D Water WelEs
Mailing Address: 3530 W. Spence Lane, WasiAa, AK 99823
�'55—
�!�a /
Attention: The well driller shall provide a well log to the
On-site Water and Wastewater Section within 30 days of
completion.
Water Sample Results:
Arsenic: ug/L
Nitrates: mg/L
Coliform Bacteria: colonies/100mL
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP251201
Work Type: WellSeptic Initial
Tax Code Number: 06723139000
Site Legal Address: OVERLOOK ESTATES #3 LT 26 G:
Site Mailing Address: 27741 WILDE CIR, Eagle River
Owner: EKLUTNA INC
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Effective Date:
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
l
f-
I)aparfmfri�r
6/30/2025
6/30/2026
57070
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Z Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
r— -: 0
Received By: � Date- _
Issued By: Date:
i �2 C)
3
ON -SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 067-231-39
Property owner(s) Eklutna Inc Day phone
Mailing address 16515 Centerfield Dr #100, Eagle River, AK 99577
Site address NHN Wilde Cir
Legal description
Overlook Estates #3, Lot 26
Number of Bedrooms 3
Engineering Firm Forge Engineering
Building Permit Number f2jS — Not Applicable F-1
APPLICATION IS FOR:
APPLICATION IS AN:
(Z all that apply)
Absorption Field
Initial El
Septic Tank
El
Upgrade EJ
Holding Tank
0
Renewal 0
Privy
D
Well
D
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Permit/Rush Fees: <DWo
Date of Payment: G L2312s-
Permit No. 0S 29 0
Waiver Fees:
Date of Payment:
Waiver No.
Distance:
June 18, 2025
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Overlook Estates #3, Lot 26 – Wilde Cir
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot intends to build a 3-bedroom home on the property, so we are
submitting this permit application for the construction of a new well and septic system. The
attached site plan identifies the location of the home as well as the proposed well, septic location
and alternate site. No conflicts exist between this proposed system and any other well or septic
system, whether on this lot or adjacent lots.
The ground surface on the lot has a moderate slope from north to south. There are no slopes greater
than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on
the site plan showing the grade and direction of flow. Stormwater drainage will not impact this
septic system. The new trench will be constructed parallel to the slope as much as possible.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all
wells and surface water, and more than 5’ away from the septic tank. The alternate site is located
more than 6’ away.
Please refer to the attached test hole log, plan and profile pages for the septic design. If this design
is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251201, Curtis Townsend, 06/30/25
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
1"=50'
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
PV - PUMP VAULT
LEGEND
OVERLOOK ESTATES #3, LOT 26
FEET
0 50 100
SEPTIC PLAN
6/16/25
15' UTILITY EASEM
E
N
T
WILDE CIR
EA
G
L
E
R
I
V
E
R
R
O
A
D
PERMITTED SEPTIC SYSTEM
DOES NOT IMPACT PROPOSED
SYSTEM
UNDEVELOPED PROPOSED WELL
ALTERNATE SITE CAT III 20' X 5',
0.5' EFFECTIVE DEPTH
3-BDRM HOME
360
365
370
375
380
385
390
395
TH#1
CONFIRMATION TEST HOLE TO
BE DUG AT TIME OF INSTALL
ST
R
E
A
M
1000-GAL SEPTIC TANK
(2) 45' LONG X 5' WIDE, 0.5'
EFFECTIVE DEPTH TRENCHES
STREAM 100' OFFSET, CONFIRM
SEPARATION TO ALL SEPTIC
DURING INSTALLATION
FCO
2CO
FS
CO
CO
CO
CO MT
MTMT
MT
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251201, Curtis Townsend, 06/30/25
OVERLOOK ESTATES #3, LOT 26
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
DRAINFIELD ROCK
3'
DESIGN FACTORS:SYSTEM REQUIREMENTS:
450 GPD PEAK FLOW
PERK RATE: <1 MIN/IN
APPLICATION RATE: 1.0 GPD/SF
5' WIDE TRENCH SYSTEM
1000-GAL SEPTIC TANK
BOTTOM OF TRENCH: 4.0' BELOW GRADE (MAX DEPTH 10')
FLOW LINE ELEVATION: 3.5' BELOW GRADE
450 GPD / 1.0 GPD/SF / 5' WIDE * 1.0 RED FACTOR [0.5' DEEP] = 90 LF TRENCH REQUIRED
(90 LF SPECIFIED)
MOA APPROVED SAND
4" PERFORATED PVC
(HOLES DOWN)6"
6/16/25
PROVIDE ADDITIONAL FILL TO
ACCOUNT FOR SETTLEMENT
5'
6"
2'
GEOTEXTILE FABRIC
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251201, Curtis Townsend, 06/30/25
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
DEPTH
(feet)
TEST HOLE 1
DATE READING NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERCOLATION RATE: (MIN/INCH)
(inches)(inches)
DATE OF MONITORING
DEPTH TO WATER AFTER MONITORING
<1
6/6/25 1
2
3
4
5
6GW (SILTY SANDY GRAVEL)
Professional Engineers Stamp:
OVERLOOK ESTATES #3, LOT 26
6/6/25 067-231-39
KOUROSH PARTOW
159 8
16
OB
0.1
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
PERC TEST LOCATION
TECHNICIAN: JUSTIN EARLS
165 8
16
16'
6/13/25
COMMENTS:
SITE PLAN
6
USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED
6/16/25
MOISTURE NOTED AT TIME OF DIGGING?YES
159 8
160.1 165 8
16 6
159 8
160.1 165 8
16 6
159 8
160.1 165 8
16 6
159 8
160.1 165 8
16 6
159 8
160.1 165 8
16 6
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251201, Curtis Townsend, 06/30/25
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: (907)343-7904
On -Site Water & Wastewater Section Fax: (907)343-7997
Certificate of On -Site Systems Approval
OSC251536
Parcel ID 067 -231-39 Expiration Date
Legal description OVERLOOK ESTATES #3 LT 26
Site address 27741 WILDE CIR
Current property owner(s) CLUFF JAE
X The On-site system(s) is/are approved for 3 bedrooms
By:
11/04/2026
Conditional approval for bedrooms, with the following stipulations:
Comments or conditions:
No comments
Original Certificate Date:
12/3/2025
This rtificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
s em(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage,
evelopment Service Department (DSD) issues COSAs based upon representations provided by an
independent professional engineer. The Municipality of Anchorage is not responsible for errors or
omissions in the professional engineer's submittal.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
MUNICIPALITY OF ANCHORAGE
Development Services Department = _.- Phone: 907-343-7904
On -Site Water & Wastewater Section � � Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 067-231-39
Complete legal description Overlook Estates #3, Lot 26
Location (site address) 27741 Wilde Cir
Current property ownerEklutna Inc s} Day phone
2. ON-SITE SYSTEMS SIZED FOR 3 BEDROOMS
3. TYPE OF WATER SUPPLY: 0 Private Well serving k-1— dwelling units
❑ Other Non-public well as regulated by MOA ❑ Water Storage
❑ Community Well or Public
4. TYPE OF WASTEWATER DISPOSAL: n Private Septic ❑ Private Septic serving 2 dwelling units
171 Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ❑ Steel no Plastic ❑ Concrete ❑ Fiberglass
Age NEW - See advisory if steel or fiberglass older than 20 years
6. ABSORPTION FIELD: Fl AWWTS ❑ Bed ❑,Deep Trench 0 Wide Trench ❑ Seepage Pit
Waiver request for: Distance:
Expedited review requested: ❑ ;
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ 7S Waiver Fee $
Date of PaymentDate of Payment
COSA'# 00V t Waiver #
COSAApplication Apr2025,doc
COSA Checklist_May2025.docx
COSA Checklist
Legal Description: Parcel ID:
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled Total depth ft
Cased to ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Well production at time of test gpm
Water storage tank volume gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in septic tank
Date of pumping
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. DISPOSAL FIELD DATA
Which system tested (date installed)
ALL standpipes present per record drawing
Total measured depth from grade ft (max)
Measured depth to pipe invert from grade ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes go to bottom of effective.
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months)
If yes, enter date
Adequacy test date
Results Pass
Fluid depth prior to test in
Water added gal
New fluid depth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) in
Effective depth used in
Effective depth remaining in
Comments/Deficiencies:
COSA Checklist_May2025.docx
E. SEPARATION DISTANCES
From Well on Lot to:(Please enter distances if less than required)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’Yes if No ft
Disposal Field on Lot > 100’Yes if No ft
Neighboring Disposal Fields > 100’
Yes if No ft
Sewer Line/Main > 100’ Yes if No ft
Sewer Manhole/Cleanout > 100’
Yes if No ft
Sewer Service/Septic Line > 25’Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Disposal Field(s) on Lot to:(Please enter distances if less than required)
Tank to Foundation > 10’Yes if No ft
Field to Foundation > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main/Service Line > 10’Yes if No ft
Surface Water > 100’Yes if No ft
Wells on Adjacent Lots:
Wells > 100’Yes if No ft
Community Wells > 200’Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm Phone
Engineer’s Printed Name Date
610 E 5th Avenue
Anchorage, Alaska 99501
(907) 306-8104
mail@S4AK.com
Land Surveying
Land Development Consultants
Subdivision Specialists
Construction Surveying
AECC#173042
S4
Group
Asbuilt
Lot 26
Overlook Estates Addition 3
Subdivision
0 50'
GRAPHIC SCALE
11/21/2025