Loading...
HomeMy WebLinkAboutT15N R2W SEC 25 LT 8015N R2W SEC 25 ;,"NAT-us MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP251249 Work Type: WellSeptic Initial Tax Code Number: 05128228000 Site Legal Address: T15N R2W SEC 25 LT 80 G:0753 Site Mailing Address: Owner: MCLEOD ALLEN & JENNIFER Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 7/25/2025 7/25/2026 108900 Q Disposal Field P Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing r�� r Received By: € Date: Issued By: �- Date: 5/7z_ - 3 In M MUNICIPALITY OF Development Services Department On -Site Water & Wastewater Section ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 051-282-28 Phone: 907-343-7904 Property owner(s)Allen & Jennifer Mcleod Day phone (281)703-2613 Mailing address 19369 Klondike St, Chugiak, AK 99567 Site address NHN Cline St (Eagle River) Legal description T1 5N R2W SEC 25, Lot 80 Number of Bedrooms Engineering Firm Forge Engineering Building Permit Number Not Applicable X APPLICATION IS FOR: APPLICATION IS AN: (Z all that apply) Absorption Field El Initial Septic Tank 0 Upgrade ❑ Holding Tank ❑ Renewal ❑ Privy ❑ Well THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Permit/Rush Fees: W-ell Date of Payment: WOE Permit No. ()g2s1)lq Waiver Fees: Date of Payment: Waiver No. Distance: July 15, 2025 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: T15N R2W SEC 25, Lot 80 – NHN Cline St Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 3-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot has a mild slope from the east to the west. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. The proposed well on this lot is shown. The septic system is more than 100’ from any property line and so will be greater than 100’ from any neighboring wells. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251249, Curtis Townsend, 07/25/25 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=50' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND T15N R2W SEC 25, LOT 80 FEET 0 50 100 SEPTIC PLAN 7/15/25 50' UTILITY EASEMENT 3-BDRM HOME 250249248 247 246 245 PROPOSED WELL TH#1 MT MT MT MT CO CO CO CO 1000-GAL SEPTIC TANK (2) 45' LONG X 5' WIDE, 0.5' EFFECTIVE DEPTH TRENCHES ALTERNATE SITE PROPOSED SYSTEM >100' FROM EDGE OF PROPERTY THEREFORE >100' FROM ALL EXISTING WELLS CL I N E S T APPROX NEIGHBORING SEPTIC LOCATION LOT 81 SEPTIC >100'2CO FCO FS Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251249, Curtis Townsend, 07/25/25 T15 R2W SEC 25, LOT 80 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER DESIGN FACTORS:SYSTEM REQUIREMENTS: 450 GPD PEAK FLOW PERK RATE: <1 MIN/IN APPLICATION RATE: 1.0 GPD/SF 5' WIDE TRENCH SYSTEM w/ 2' SAND FILTER 1000-GAL SEPTIC TANK BOTTOM OF TRENCH: 4.0' BELOW GRADE (MAX 8.0') FLOW LINE ELEVATION: 3.5' BELOW GRADE 450 GPD / 1.0 GPD/SF / 5' WIDE * 1.0 RED FACTOR [0.5' DEEP] = 90.0 LF TRENCH REQUIRED (90.0 LF SPECIFIED) 7/15/25 6" 5' 2' 6" 3' Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251249, Curtis Townsend, 07/25/25 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING DEPTH TO WATER AFTER MONITORING <1 6/30/25 1 2 3 4 5 6GM (SILTY SANDY GRAVEL) Professional Engineers Stamp: T15 R2W SEC 25, LOT 80 6/30/25 015-282-28 ALLEN MCLEOD 159 8 16 OB 0.1 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: JUSTIN EARLS 165 8 16 NONE 7/7/25 COMMENTS: SITE PLAN 6 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED 7/15/25 MOISTURE NOTED AT TIME OF DIGGING?NO 159 8 160.1 165 8 16 6 159 8 160.1 165 8 16 6 159 8 160.1 165 8 16 6 159 8 160.1 165 8 16 6 159 8 160.1 165 8 16 6 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251249, Curtis Townsend, 07/25/25