On -Site Water & Wastewater System Permit
Permit Number: OSP251241
Work Type: WellSeptic Initial
Tax Code Number: 02051101000
Site Legal Address: BURLWOOD TR A G:3240
Site Mailing Address: 7820 JAMIE AVE, Anchorage
Owner: SPINELL HOMES INC
Design Engineer: PANNONE ENGINEERING SERVICES
This permit is for the construction of:
Effective Date
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
7/29/2025
7/29/2026
1745668
Q Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
7
Received By: ��- Date:
L IZ
2
Issued By: Date:
�
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section
ON -SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 020-511 -01
Property owner(s) Copper River Development, LLC
Mailing address 2520 Sebring Circle Anchorage, AK
Site address INHIN Jamie Ave
Legal description
Burlwood Tr A
Number of Bedrooms 7
Engineering Firm Pannone Engineering Services, LLC.
Building Permit Number
Day phone
Not Applicable M
APPLICATION IS FOR: APPLICATION IS AN:
(Z all that apply)
Disposal Field
Initial F]
Septic Tank
El Upgrade ❑
Holding Tank
❑ Renewal ❑
Privy
❑
Well
Water Storage
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Permit/Rush Fees: 1092-1(1-
Date of Payment: 71101,x
Permit No. 05fZSj2q(
May 2025
Waiver Fees:
Date of Payment:
Waiver No.
Distance:
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@panengak.com
Mailing: P.O.Box 1807, Palmer, AK 99645
Telephone: (907) 745-8200 FAX: (907) 745-8201
Municipality of Anchorage
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, Alaska
Subject: Burlwood Tr A
Private Well and Septic System Permit Request
This is a design narrative for a permit to install an initial well and septic system on the subject property. The
installation will serve a proposed seven (7) bedroom house. This lot and surrounding lots are served by private wells.
Currently there are no wells within 100ft of the proposed installation.
1. Soils: Several test holes were performed on this lot by Pannone Engineering Services, LLC and Triad Engineering,
LLC. Approximate locations are shown on the attached site plan. TH-2 PES was used for the basis of design for
the soil absorption system. Groundwater was observed during the excavation of the test hole at a depth of 9.0’
BGS, and bedrock was not encountered. Groundwater was observed in the test hole monitor tube after 7-days
at a depth of 8.0’ BGS. Based on the results of the percolation test and overall soils appearance an application
rate of 1.2 gpd/SF was used for the design of a conventional wastewater treatment system in the area of the
test hole.
2. Soil Absorption System Design: See design package.
3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field.
4. Topography: See attached site plan for area topography.
5. Drawing Markings: The Drawings are marked “For MOA Review Only”. When written notification that the
review is complete and no further comments are received from MoA On-Site Department, the note will be removed
and “For Construction” drawings will be issued.
The proposed installation will not affect the future development of this or the surrounding lots.
If you have any questions, please contact me at (907) 745-8200.
Sincerely,
SRP
Steven R. Pannone, P.E. F. ASCE
Owner/Civil Engineer
10 July 2025
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251241, Curtis Townsend, 07/29/25
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251241, Curtis Townsend, 07/29/25
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251241, Curtis Townsend, 07/29/25
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251241, Curtis Townsend, 07/29/25
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251241, Curtis Townsend, 07/29/25