HomeMy WebLinkAboutT16N R1E SEC 28 N2NE4NE4
T16N R1E SEC 28
N2NE4NE4
#052-331-05
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP251256
Work Type: WellSeptic Initial
Tax Code Number: 05233105000
Site Legal Address: T16N R1 E SEC 28 N2NE4NE4 G:1905
Site Mailing Address: 32551 EKLUTNA LAKE RD, Chugiak
Owner: ANDERSEN JOHN
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Effective Date:
Expiration Date
Lot Size in Sq Ft:
Total Bedrooms:
7/30/2025
7/30/2026
871200
Z Disposal Field Z Septic Tank ❑ Holding Tank ❑ Privy Z Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: Date:
Issued By: Date: _ '2 c -y
4
ON -SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 052-331-05
Property owner(s) John Anderson Day phone
Mailing address400 W 76th Ave Apt 104, Anchorage, AK 99518
Site address32551 Eklutna Lake Rd
Legal description T1 6N R1 E SEC 28 N2NE4NE4
q
Number of Bedrooms S
Engineering Firm Forge Engineering
Building Permit Number R25-2619
Not Applicable n
APPLICATION IS FOR: APPLICATION IS AN:
(Z all that apply)
Absorption Field
M Initial El
Septic Tank
0 Upgrade n
Holding Tank
❑ Renewal El
Privy
❑
Well
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
'30
Permit/Rush Fees: ?
Date of Payment:
Permit No. C)
Waiver Fees:
Date of Payment:
Waiver No.
Distance:
July 15, 2025
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: T16N R1E SEC 28 N2NE4NE4 - 32551 Eklutna Lake Rd
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot intends to build a 3-bedroom home on the property, so we are
submitting this permit application for the construction of a new well and septic system. To be
conservative the proposed system is sized for 4-bedrooms. The attached site plan identifies the
location of the home as well as the proposed well, septic location and alternate site. No conflicts
exist between this proposed system and any other well or septic system, whether on this lot or
adjacent lots.
The ground surface on the lot slopes steeply from the north to the south. The slopes are fairly
uniform, between 25-40%, although there is a slightly flatter area where the house is proposed.
While there are slopes greater than 25% in the immediate vicinity of the septic trenches, there are
no slopes greater than 46%, and the attached steep slopes profile show that there will be no
daylighting of effluent from the trenches. Stormwater drainage will not impact this septic system.
The new trench will be constructed parallel to the slope as much as possible.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all
wells and surface water, and more than 5’ away from the septic tank. The alternate site is located
more than 6’ away.
Please refer to the attached test hole logs, plan and profile pages for the septic design. If this design
is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251256, Curtis Townsend, 07/30/25
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FD - FLOW DIVERTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
1"=50'
T16N R1E SEC 28 N2NE4NE4
FEET
0 50 100Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
7/11/25
SEPTIC PLAN
3-BDRM HOME
TH-1
TH-2
PROPOSED WELL, ENSURE 100'
FROM ALL SEPTIC
1300
1305
1310
1315
1325
1330
1335
1340
1345
1350
1355
1360
1365
1370
1295
1290
1320
1250-GAL SEPTIC TANK, ENSURE
5' FROM DECK
(2) 70' LONG X 5' WIDE, 2'
EFFECTIVE DEPTH TRENCHES,
ENSURE 10' FROM FOUNDATION
FCO
CO
COCO
CO
MT
MT
MT
MT
FS
2CO
ALTERNATE SITE CAT III 25' X 5',
0.5' EFFECTIVE DEPTH
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251256, Curtis Townsend, 07/30/25
T16N R1E SEC 28 N2NE4NE4
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
DESIGN FACTORS:SYSTEM REQUIREMENTS:
600 GPD PEAK FLOW
PERK RATE: 20 MIN/IN
APPLICATION RATE: 0.6 GPD/SF
5' WIDE TRENCH SYSTEM
1250-GAL SEPTIC TANK
BOTTOM OF TRENCH: 6.0' BELOW GRADE
FLOW LINE ELEVATION: 4.0' BELOW GRADE
600 GPD / 0.6 GPD/SF / 5' WIDE * 0.7 RED FACTOR [2.0 DEEP] = 140 LF TRENCH REQUIRED
(140 LF SPECIFIED)
7/11/25
2'
6"
3'-6"
4" PERFORATED PVC (HOLES DOWN)
DRAINFIELD ROCK
GEOTEXTILE FABRIC
PROVIDE ADDITIONAL FILL TO
ACCOUNT FOR SETTLEMENT
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251256, Curtis Townsend, 07/30/25
1305.00
1310.00
1315.00
1320.00
1325.00
1330.00
1335.00
1340.00
1345.00
1350.00
1355.00
1305.00
1310.00
1320.00
1330.00
1340.00
1350.00
0+00.00 0+50.00 0+90.00
1"=10'
SLOPE CROSS SECTION
SEPTIC TRENCHES
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
46% AN
G
L
E
OF
EF
FLUE
N
T INFL
UE
N
C
E
2:1 MAX SLOPES
6.0
FEET
0 10 20
7/14/25
T16N R1E SEC 28 N2NE4NE4
ALTERNATE SITE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251256, Curtis Townsend, 07/30/25
�FtCTE/?Rq
AizcT ExuA
CONSULTING, INC
20441 Ptarmigan, Eagle River,AK 99577
` ap Office (907) 696-6111, Fax (907) 868-3793
N AK. sOSY'f.�
SOILS PERCOLATION TEST
Performed for: John Anderson
Project. T16N R1E Sec 28 N2NE4NE4
Depth
1 _ 0'-1.5' Org
2- 1.5'-2.5' GM
4-1 1 - Pere Bench #1 @3.5'
5- I I 2.5'-12' SW
7-
8-
9-
10-
]I-
12-1
13-
14-
15-
16-
17-
18-
B.O.H. 12
19-
i
��
� ��TH 3
�i
KENNETH M. L 1
�i 1 t 6 `
Date Performed: 3/21/25
TEST HOLE # TH - 1
SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
Was Ground water encountered? No What depth? NA
Depth to water after monitoring? None Date 3/28/25
(Depth below grade)
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
1
3/21/25
2:00
10/16"
2
2:30
30 Min
2 8/16"
1 8/16"
3
*
3:00
30 Min
4 0/16"
1 8/16"
4
3:00
1 016"
5
*
3:30
30 Min
2 8/16"
1 8/16"
6
7
8
9
10
11
12
*
Water
Added
Percolation Rate 20 (min/in) Pere Hole Diameter 6 "
Test Run Between 3.5 feet and 4 feet
I, Kenneth M. Duffus, certify that this test was performed in accordance with all State
and Municipal guidelines in effect on this date.
.00
o �jtcTRRq r OF A
CONSULTING, INC
20441 Ptarmigan, Eagle River,AK 99577 4 9 TH
- Office (907) 696-6111, Fax (907) 868-3793 j
~crarytr'N3Ll' r NG '
'• AK. 9VSTr- KENNETH lYt, i] iP' /
11. _ 7116
SOILS PERCOLATION TEST , �"Ilk
`-ft.
4p'
Performed for: John Anderson
Project: T16N R1E Sec 28 N2NE4NE4
Depth
(Feet)
1-0'-1.5' Org
2-
3- - Pere Bench #1 @3'
4-
5- 1.5'-15' GW/GP
6-
7-
8-
9-
10-
11-
12-
13-
14-
15-
16-
17-
18-
B.O.H.15'
19-
Date Performed: 3/21/25
TEST HOLE # TH - 2
SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
Was Ground water encountered? No What depth? NA
Depth to water after monitoring? None Date 3/28/25
(Depth below grade)
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
1
3/21/25
2:20
12/16"
2
2:25
5 Min
7 2/16"
6"
3
*
2:25
12/16"
4
2:30
5 Min
7 2/16"
6"
5
*
2:30
12/16"
6
2:35
5 Min
7 2/16"
6"
7
*
2:35
12/16"
8
2:40
5 Min
7 2/169'
6"
9
*
2:40
1 2/16"
10
2:45
5 Min
7 2/16"
6"
11
*
2:45
12/16"
12
2:50
5 Min
7 2/16"
6"
*
Water
Added
Percolation Rate 0.8 (min/in) Perc Hole Diameter 6 "
Test Run Between 3 feet and 3.5 feet
I, Kenneth M. Duffus, certify that this test was performed in accordance with all State
and Municipal guidelines in effect on this date.
o
1
O O mom
I
o ^ o o il? 3"E , a a �
z�zk zt�x
Q
0 a n O
Z
r i n a
a I
� 2 2 2
2
a �
ro V Z
oIt. "n 2o 5a o
2 O O y y
'Oh �aryOaH
�yLo a�2
a � � to
moo ova
y2� .rnc�
anm a~22
� ao�
"X :r
5.0 JR m
IpOo o
Om OOO Nrt
JJt] J0-
(TO
cn(i
FANNz6-3
col 1' O0
NJJ(l
top
N
ti
r
a
cn>,
N
n
n
l
r
rl�
O
a
Q
m
o
N
a
U
Iv
O
O
O
O
y
O
, SS'099 3„ 00, 61S.OS
-.w
W
�
o
o
Si
a
,!S'OLS 3 Z4,ZtOS
(.a
m
•S
28.0
N 9.5 'cif
O
v O C
C w
m w
0
29.5
yS� ma's