Loading...
HomeMy WebLinkAboutPYRENEES ESTATES TR A0 0 L ESTATES #067-621-03 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP251324 Work Type: WellSeptic Initial Tax Code Number: 06762103000 Site Legal Address: PYRENEES ESTATES TR A G:0804 Site Mailing Address: Owner: SAVIKKO JASON & MERLYN Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date: Expiration Date Lot Size in Sq Ft: Total Bedrooms: 9/25/2025 9/25/2026 435983 Q Disposal Field Z Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing r Received By: Date: Issued By: Date: MUNICIPALITY OF ANCHORAGE J�j Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 067-621-03 Property owner(s) Jason & Merlyn Savikko Day phone Mailinq address 19924 1 st St, Eagle River, AK 99577 Site address NHN Misty Mountain Rd, Eagle River Legal description Pyrenees Estates, Tract A Number of Bedrooms 1 Engineering Firm Forge Engineering Building Permit Number APPLICATION IS FOR: (Z all that apply) Absorption Field 0 Septic Tank El Holding Tank El Privy F Well F I Not Applicable F-1 APPLICATION IS AN: Initial Upgrade ❑ Renewal ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Permit/Rush Fees: �91216 Date of Payment: W12-12- Permit No. 05P251 oq Waiver Fees: Date of Payment: Waiver No. Distance: September 25, 2025 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Pyrenees Estates, Tract A – NHN Misty Mountain Rd Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a shop with a studio apartment on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes from the north east down to the south west at around 20%. The slopes do get close to 25% in some areas, so refer to the attached profile which shows the effluent won’t daylight. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251324, Curtis Townsend, 09/25/25 CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FD - FLOW DIVERTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND 1"=50' PYRENEES ESTATES, TRACT A FEET 0 50 100Benjamin Schiller CE 12592REGISTEREDPROFESSIONA L E N GINEER 9/3/25 SEPTIC PLAN 705 710715 720725 730 735 740 745 750 755 760 765 770 775 780 TH#1 PROPOSED WELL LOCATION SHOP w/ STUDIO APARTMENT 1000-GAL SEPTIC TANK 45' LONG X 5' WIDE, 0.5' EFFECTIVE DEPTH TRENCH 6 0 ' P R I V A T E A C C E S S E A S E M E N T MT CO MT CO FCO ALTERNATE SITE APPROXIMATE 100' RADIUS FROM NEIGHBORING WELL WELL ON T13N R1E SEC 4 TR 4 FAR BEYOND 100' FROM EDGE OF PROP LINE UNKOWN WELL LOCATION ON FALLING WATER, BLOCK 3 LOT 4. LOT LINE BEYOND 100' FROM PROPOSED SYSTEM Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251324, Curtis Townsend, 09/25/25 PYRENEES ESTATES, TRACT A TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER DESIGN FACTORS:SYSTEM REQUIREMENTS: 150 GPD PEAK FLOW PERK RATE: <1.0 MIN/IN APPLICATION RATE: 1.0 GPD/SF 5' WIDE TRENCH SYSTEM 1000-GAL SEPTIC TANK BOTTOM OF TRENCH: 4.0' BELOW GRADE MAX FLOW LINE ELEVATION: 3.5' BELOW GRADE 150 GPD / 1.0 GPD/SF / 5' WIDE * 1.0 RED FACTOR [0.5' DEEP] = 30.0 LF TRENCH REQUIRED (45.0 LF SPECIFIED) 9/3/25 6" 5' 2' 6" 3' 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK GEOTEXTILE FABRIC PROVIDE ADDITIONAL FILL TO ACCOUNT FOR SETTLEMENT MOA APPROVED SAND 6" Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251324, Curtis Townsend, 09/25/25 710.00 715.00 720.00 725.00 730.00 735.00 740.00 745.00 710.00 720.00 730.00 740.00 0+00.00 0+50.00 0+76.00 1"=10' SLOPE CROSS SECTION SEPTIC TRENCH Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 46 % AN G L E OF EF F L UE N T INFLU EN C E 3:1 MAX SLOPES PYRENEES EST, TRACT A 6.0 FEET 0 10 20 8/22/23 ALTERNATE SITE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251324, Curtis Townsend, 09/25/25 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING DEPTH TO WATER AFTER MONITORING <1 8/21/25 1 2 3 4 5 6GM (SILTY SANDY GRAVEL) Professional Engineers Stamp: PYRENEES ESTATES TRACT A 8/21/25 067-621-03 SKYLER QUINN 93 8 16 OB Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: JUSTIN EARLS 99 8 16 NONE 8/29/25 COMMENTS: SITE PLAN 6.0 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED EXCEPT WHERE NOTED. 9/3/25 MOISTURE NOTED AT TIME OF DIGGING?NO 0.5 93 8 16 99 8 16 6.00.5 93 8 16 99 8 16 6.00.5 93 8 16 99 8 16 6.00.5 93 8 16 99 8 16 6.00.5 93 8 16 99 8 16 6.00.5 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251324, Curtis Townsend, 09/25/25