Loading...
HomeMy WebLinkAboutSHANGRI-LA ESTATES-EAST PH 2 BLK 5 LT 3IMWI L A b4 MPT ESTATES - EAST PH 2 Block 5 tj A( MVISMST.A W. in '*V. MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP251376 Work Type: WellSeptic Initial Effective Date: Expiration Date: Tax Code Number: 02004386000 Site Legal Address: SHANGRI-LA ESTATES -EAST PH 2 BLK 5 LT 3 G:3239 Site Mailing Address: Owner: FORGE ENGINEERING Design Engineer: FORGE ENGINEERING This permit is for the construction of: Q Disposal Field 2 Septic Tank ❑ Holding Tank ❑ Privy 11��nr �, 'xx x r Sit. L)ehartInent 10/16/2025 10/16/2026 Lot Size in Sq Ft: 54213 Total Bedrooms: 4 Non -Public R1 Water Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On -Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: A test hole is required prior to construction of the absorption field, in the location shown on the site plan, to confirm minimum separation to impermeable soil and seasonal high groundwater, as well as percolation rate. Construction may proceed at your own risk prior to 7-day groundwater monitoring. If results require a design change, construction shall stop pending approval of a change order. Please submit results with the inspection report (or change order, if required). Issued To: FORGE EN INEERING t Issued By: Date: 10/16/2025 Date: 10/16/2025 t I V "TTRUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 r)n_.qifi= \A/ckfar A \A/nQfeZXA1Mfar _(Zinf-finn ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 020-043-86 Property owner(s) K&M Property LLC Day phone Mailina address 10650 Mountain Air Dr, Anchorage, AK 99516 Site address NHN Mountain Air Dr, Anchorage AK Legal description Shangri-La Estates East Ph2, Block 5 Lot 3 Number of Bedrooms 4 Engineering Firm Forge Engineering Building Permit Number Not Applicable F-1 APPLICATION IS FOR: APPLICATION IS AN: (Z all that apply) Disposal Field 0 Initial Septic Tank F Upgrade 0 Holding Tank El Renewal 0 Privy F-1 Well FE Water Storage D THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: Permit/Rush Fees: :51Y a'aiver Fees: Date of Paymentl 64L� 12 Date of Payment: Permit No. 0S e � S- 1 Waiver No. May 2025 October 13, 2025 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Shangri-La Estates East Ph2, Block 5 Lot 3 – Mountain Air Dr Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot has a slope of 15-25% across the entire lot from the SW to the NE. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Triad Engineering did a test hole on this lot in 2022; we are using that log for this design but a confirmation test hole will be required as the proposed trenches are not within 30’ of the Triad’s test hole. Please refer to the attached, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251376, Curtis Townsend, 10/16/25 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=40' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND 2COMT SHANGRI-LA ESTATES EAST PH2, BLOCK 5 LOT 3 FEET 0 40 80 FCO SEPTIC PLAN 10/13/25 FS 4-BDRM HOME TRIAD ENGINEERING TH EDGE OF WETLANDS WETLANDS PROPOSED WELL, ENSURE 100' FROM ALL SEPTIC CONFIRMATION TH TO BE DONE AT TIME OF INSTALL M O U N T A I N A I R D R 1250-GAL SEPTIC TANK (2) 60' LONG X 5' WIDE, 0.5' EFFECTIVE DEPTH TRENCHES CO CO CO CO MT MT MT 985 980 970 970 965 960 ALTERNATE SITE CAT III 20' LONG X 5' WIDE, 0.5' EFFECTIVE DEPTH Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251376, Curtis Townsend, 10/16/25 SHANGRI-LA ESTATES EAST PH 2, BLOCK 5 LOT 3 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER DESIGN FACTORS:SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: <1 MIN/IN APPLICATION RATE: 1.0 GPD/SF 5' WIDE TRENCH SYSTEM w/ 2' SAND FILTER 1250-GAL SEPTIC TANK BOTTOM OF TRENCH: 4.0' BELOW GRADE (5.0' MAX) FLOW LINE ELEVATION: 3.5' BELOW GRADE 600 GPD / 1.0 GPD/SF / 5' WIDE * 1.0 RED FACTOR [0.5' DEEP] = 120.0 LF TRENCH REQUIRED (120.0 LF SPECIFIED) 10/10/25 6" 5' 2' 6" 3' 6" 4" PERFORATED PVC (HOLES DOWN) GEOTEXTILE FABRIC PROVIDE ADDITIONAL FILL TO ACCOUNT FOR SETTLEMENT MOA APPROVED SAND Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251376, Curtis Townsend, 10/16/25