On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP251376
Work Type: WellSeptic Initial
Effective Date:
Expiration Date:
Tax Code Number: 02004386000
Site Legal Address: SHANGRI-LA ESTATES -EAST PH 2 BLK 5 LT 3 G:3239
Site Mailing Address:
Owner: FORGE ENGINEERING
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Q Disposal Field 2 Septic Tank ❑ Holding Tank ❑ Privy
11��nr
�, 'xx x r Sit.
L)ehartInent
10/16/2025
10/16/2026
Lot Size in Sq Ft: 54213
Total Bedrooms: 4
Non -Public
R1 Water Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Coodinate with On -Site staff regarding preferred method.
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: A test hole is required prior to construction of the absorption field, in the location shown on
the site plan, to confirm minimum separation to impermeable soil and seasonal high groundwater, as well as
percolation rate. Construction may proceed at your own risk prior to 7-day groundwater monitoring. If results
require a design change, construction shall stop pending approval of a change order. Please submit results with
the inspection report (or change order, if required).
Issued To: FORGE EN INEERING
t
Issued By:
Date: 10/16/2025
Date: 10/16/2025
t I V
"TTRUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
r)n_.qifi= \A/ckfar A \A/nQfeZXA1Mfar _(Zinf-finn
ON -SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 020-043-86
Property owner(s) K&M Property LLC Day phone
Mailina address 10650 Mountain Air Dr, Anchorage, AK 99516
Site address NHN Mountain Air Dr, Anchorage AK
Legal description Shangri-La Estates East Ph2, Block 5 Lot 3
Number of Bedrooms 4
Engineering Firm Forge Engineering
Building Permit Number
Not Applicable F-1
APPLICATION IS FOR: APPLICATION IS AN:
(Z all that apply)
Disposal Field
0 Initial
Septic Tank
F Upgrade 0
Holding Tank
El Renewal 0
Privy
F-1
Well
FE
Water Storage
D
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
Permit/Rush Fees: :51Y a'aiver Fees:
Date of Paymentl 64L� 12 Date of Payment:
Permit No. 0S e � S- 1 Waiver No.
May 2025
October 13, 2025
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Shangri-La Estates East Ph2, Block 5 Lot 3 – Mountain Air Dr
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot intends to build a 4-bedroom home on the property, so we are
submitting this permit application for the construction of a new well and septic system. The
attached site plan identifies the location of the home as well as the proposed well, septic location
and alternate site. No conflicts exist between this proposed system and any other well or septic
system, whether on this lot or adjacent lots.
The ground surface on the lot has a slope of 15-25% across the entire lot from the SW to the NE.
There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate
site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater
drainage will not impact this septic system. The new trench will be constructed parallel to the slope
as much as possible.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all
wells and surface water, and more than 5’ away from the septic tank. The alternate site is located
more than 6’ away. Triad Engineering did a test hole on this lot in 2022; we are using that log for
this design but a confirmation test hole will be required as the proposed trenches are not within
30’ of the Triad’s test hole. Please refer to the attached, plan and profile pages for the septic design.
If this design is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251376, Curtis Townsend, 10/16/25
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
1"=40'
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
2COMT
SHANGRI-LA ESTATES EAST PH2, BLOCK 5 LOT 3
FEET
0 40 80
FCO
SEPTIC PLAN
10/13/25
FS
4-BDRM HOME
TRIAD ENGINEERING TH
EDGE OF WETLANDS
WETLANDS
PROPOSED WELL, ENSURE 100'
FROM ALL SEPTIC
CONFIRMATION TH TO
BE DONE AT TIME OF
INSTALL
M
O
U
N
T
A
I
N
A
I
R
D
R
1250-GAL SEPTIC TANK
(2) 60' LONG X 5' WIDE, 0.5'
EFFECTIVE DEPTH TRENCHES
CO
CO
CO
CO
MT
MT
MT
985
980
970
970
965
960
ALTERNATE SITE CAT III 20' LONG
X 5' WIDE, 0.5' EFFECTIVE DEPTH
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251376, Curtis Townsend, 10/16/25
SHANGRI-LA ESTATES EAST PH 2, BLOCK 5 LOT 3
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
DESIGN FACTORS:SYSTEM REQUIREMENTS:
600 GPD PEAK FLOW
PERK RATE: <1 MIN/IN
APPLICATION RATE: 1.0 GPD/SF
5' WIDE TRENCH SYSTEM w/ 2' SAND FILTER
1250-GAL SEPTIC TANK
BOTTOM OF TRENCH: 4.0' BELOW GRADE (5.0' MAX)
FLOW LINE ELEVATION: 3.5' BELOW GRADE
600 GPD / 1.0 GPD/SF / 5' WIDE * 1.0 RED FACTOR [0.5' DEEP] = 120.0 LF TRENCH REQUIRED
(120.0 LF SPECIFIED)
10/10/25
6"
5'
2'
6"
3'
6"
4" PERFORATED PVC (HOLES DOWN)
GEOTEXTILE FABRIC
PROVIDE ADDITIONAL FILL TO
ACCOUNT FOR SETTLEMENT
MOA APPROVED SAND
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251376, Curtis Townsend, 10/16/25