Loading...
HomeMy WebLinkAboutchecklistCOSA Checklist Legal Description: SOUTH LAKEWOOD HILLS; BLOCK 2, LOT 3 Parcel ID: 015-511-28 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system 1 A. WELL DATA R Well log is filed with Onsite (or attached) Date drilled *1967 Total depth 178 ft Cased to UNK ft 0 Sanitary seal is functioning correctly 0 Wires are properly protected Casing height (above ground) 12+ in. Date of flow test for COSA 9/23/2025 Static water level at beginning of test 125.5 ft Comments *NO LEGAL DESCRIPTION ON WELL LOG. B. TANK DATA Measured operating fluid level in septic tank *51" Date of pumping t b j ❑ Required maintenance completed, if AWWfS Comments: TO SLUDGE IN ST1. 50.25" IN ST2 D. DISPOSAL FIELD DATA Which system tested (date installed) 9/19/2002 Q ALL standpipes present per record drawing Total measured depth from grade 12.5 ft (max) Measured depth to pipe invert from grade 7.6 ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. ❑ Monitor tubes go to bottom of effective. If not, state depth into effective *58 .X Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced 1977 gallons 9/23/2025 date Any rejuvenation treatment (past 12 months) NO If yes, enter date Well production at time of test 7.5+ gpm Water storage tank volume N/A gallons Well disinfected for coliform test? ❑ Yes 0 No [9/coliform bacteria is Negative Nitrate 1, 00\ mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L El Arsenic less than MRL (ND) Collected by GARNESS ENGINEERING Date 9/23/2025 T STATION ❑ Require tenance co Age of lift station rs Lift station rial ents: Adequacy test date 9/23/2025 Results Q Pass Fluid depth prior to test 19.25 in Water added 579 gal New fluid depth 21 in Elapsed time 35 min Final fluid depth 14 in Absorption rate 450+ gpd FIELD STATUS — POST RECOVERY Effective depth (per record drawings) 62 in Effective depth used 18 in Effective depth remaining 44 in Comments/Deficiencies: *BASED UPON GEG ELEVATION TO INVERT OF HIGHEST CO INVERT. COSA Check] ist_May2025.docx E. SEPARATION DISTANCES From Well on Lot to: (Please enter distances if less than required) Septic Tank/Lift Station on Lot > 100' ]Z Yes if No ft Neighboring Tank > 100' M Yes if No ft Disposal Field on Lot > 100' Q✓ Yes if No ft Neighboring Disposal Fields > 100' R Yes if No ft Sewer Line/Main > 100' Ry/ if No ft Sewer Manhole/Cleanout > 100' Q✓ Yes if No ft Sewer Service/Septic Line > 2521 Yes if No ft Holding Tank > 100' 0✓ Yes if No ft Animal Containment > 50' Yes if No ft Manure/Animal Excreta Storage > 100' 0 Yes if No ft ❑ N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required) Tank to Foundation > 10' 0 Yes if No *51+ ft Surface Water > 100' Q✓ Yes if No ft Field to Foundation > 10' 0 Yes if No ft Tank to Property Line > 5' p Yes if No ft Field to Property Line > 10' [Z]Yes if No ft Water Main/Service Line > 10' ❑✓ Yes if No ft F. ENGINEER'S COMMENTS *MET CODE AT TIME OF INSTALL. Wells on Adjacent Lots: Wells > 100' Community Wells > 200' FZ Yes if No ft 0 Yes if No ft If tank or field is under driveway comment below NOTE: EXISTING STEEL SEPTIC TANK AT THE END OF ITS USEFUL LIFE. G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Garness Engineering Group, LTD. (GEG) Phone 907-337-6979 Engineer's Printed Name Jeffrey A. Gayness, P.E. Date In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend upon a variety of variables, including (but not limited to) soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail to perform adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. COSA Checklist_May2025.docx 49 TJH .... E-7953 c� 4prP,- LICENSE�Qa pr o f e s s k0000 #AECC884 ������`��