Loading...
HomeMy WebLinkAboutSPRUCE TERRACES LT 24 SPRUCE TERRACE Block Lot 24 #020-044-29 Permit Number:OSP251374 Tax Code Number:02004429000 Work Type:Septic Initial Effective Date: Design Engineer: Site Legal Address:SPRUCE TERRACES LT 24 G:3239 Owner:PANNONE ENGINEERING SERVICES Site Mailing Address:6825 AVALANCHE CIR, Anchorage Lot Size in Sq Ft:54500 Total Bedrooms:6 This permit is for the construction of: Disposal Field Septic Tank Holding Tank Privy Non-Public Water Well Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On-Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 10/15/2026 PANNONE ENGINEERING SERVICES Expiration Date: þ þ ¨¨¨¨ Issued To: Issued By: Date: Date: 10/17/2025 10/17/2025 PANNONE ENGINEERING SERVICES MUNICIPALITY OF ANCHORAGE On-Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On-Site Wastewater Disposal System Permit Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com 16 October, 2025 Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, Alaska Subject: Spruce Terraces Lot 24 6825 Avalanche Circle Septic System Permit Request This is a design narrative for a permit to install an initial septic system on the subject property. The installation will serve a proposed six (6) bedroom house. This lot and surrounding lots are served by a community well. Currently there are no wells within 200ft of the proposed installation. 1. Soils: A test hole was performed on this lot by Pannone Engineering Services, LLC on 10/15/2020 (TH-24). Groundwater was not observed during the excavation of this test hole, and bedrock was not encountered. No groundwater was observed in the test hole monitor tube after 7 -days on 10/27/2020. Twenty-seven (27) test holes were performed within this subdivision by PES for the approval of this subdivision. Bedrock, impermeable soils, or ground water, were not encountered in this subdivision within the test holes performed. Test holes in the area were all found to have a percolation rate of less than five minutes per inch (MPI ). See soils logs attached, or soils logs as documented under the subdivision, S12599/S12420. Based on the results of the surrounding percolation tests , the percolation test and test hole conducted on the subject lot and known soil types in the area , per 15.65.210.C; an application rate of 1.2 gallons/day/square foot was used for the design of a conventional wastewater system in the location as depicted in the attached site plan. PES will perform a test hole at the time of construction to verify the existing soil strata and applicability of the proposed design. Subject test hole information will be provided at the time of record drawings. 2. Soil Absorption System Design: See design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. Topography: See attached site plan for area topography. There are slopes exceeding 25% within 25-feet and 50-feet of the proposed drain field. The proposed drain field design conforms to the steep slope provisions of AMC 15.65.210.B.4.a. Exception. The soils in this area are Hydrologic Soils Group A; which contains organics underlain by poorly graded sands and gravels with silty sandy gravels below (SP) (GP) & (SM) as shown on the subject and surrounding lot soils logs. Due to the nature of and drainage capacity of the soils found in the area (HSG A), the designed infiltration line of 46% for septic system installation on steep slopes should be used instead of the assumed/worst case soil classification infiltration line of 25%. The slopes and soil types enable installation of the proposed system without the system effluent daylighting at any distance of concern. Please see sheet 2 of the attached design package for slope details. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251374, Isatou Njie, 10/17/25 Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 4. Drawing Markings: The Drawings are marked “For MOA Review Only”. When written notification that the review is complete and no further comments are received from MoA On-Site Department, the note will be removed and “For Construction” drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions, please contact me at (907) 745-8200. Sincerely, SRP Steven R. Pannone, P.E. F. ASCE Owner | Principal Engineer 16 October 2025 CO N S T R U C T I O N Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251374, Isatou Njie, 10/17/25 935 930 925 920 915 910 ORIGINAL GRADE 1 0% 33 % NOTE: 1. CONTOURS AND SLOPES ARE APPROXIMATE. 10.0 6.0 (H S G A - 46% I NF ILTRA T I O N L I N E ) (HSG A - 46% I NFILT RA T I ON LI N E) 3.8 10.0 6.0 3.8 935 930 925 920 915 910 ORIGINAL GRADE 8% 2 5% 32 % NOTE: 1. CONTOURS AND SLOPES ARE APPROXIMATE. 6.0 (HSG A - 46 % INFI LTRA T I O N LINE ) (HSG A - 46% I NFILT RATIO N LINE ) 10.0 3.7 37% 39 % 10.0 6.0 P. O . B O X 1 8 0 7 P A L M E R , A K 9 9 6 4 5 PA N N O N E E N G I N E E R I N G S E R V I C E S , L L C ( C . I . 1 0 8 8 ) PH O N E ( 9 0 7 ) 7 4 5 - 8 2 0 0 F A X ( 9 0 7 ) 7 4 5 - 8 2 0 1 DA T E SC A L E SH E E T P. I . D . N O PE R M I T N O . DR A W N RE V I S I O N S CH E C K E D LJ C FO R CO N S T R U C T I O N SP R U C E T E R R A C E S L O T 2 4 CL I E N T : S P I N E L L H O M E S , I N C . SI T E : 6 8 2 5 A V A L A N C H E C I R C L E AN C H O R A G E , A K 9 9 5 1 6 10 / 0 9 / 2 0 2 5 02 0 - 0 4 4 - 2 9 OS P X X X X X X AC P 10 / 0 9 / 2 0 2 5 ST E V E N R . P A N N O N E CE - 8 1 4 9 R E GISTEREDPROFESSI ONAL ENGINEER SE C T I O N ( S ) 1" = 1 0 ' 2 O F 3 1 SCALE: 1"=10' DRAIN FIELD SLOPE SECTION 2 SCALE: 1"=10' DRAIN FIELD SLOPE SECTION Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251374, Isatou Njie, 10/17/25 R C O N S T R U C T I O N Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251374, Isatou Njie, 10/17/25