Loading...
HomeMy WebLinkAboutCANYON VIEW ESTATES BLK 1 LT 1 CANYON VIEW ESTATES BLOCK 1 LOT 1 #021-021-34 www.sullivanwaterwells.com Pump Installation Log Well Drilling Permit Number: OSP Date of Issue Parcel Identification Number: Legal Description Property Owner Name & Address CANYON VIEW ESTATES BLK 1 LT 1 Hultquist Homes 13675 Canyon Rd. Anchorage, AK 99516 Pump Installation Date: 6/10/26 Pump Intake Depth Below Top of Well Casing: 411 feet Pump manufacturer’s Name: Grundfos Pump Model: 10SQE15-330 Pump Size: 1.5 hp Pitless Adapter Burial Depth: 11 feet Pitless Adapter Installer: Pitless Manufacturer: Unknown Disinfected Upon Completion? yes no Method of Disinfection: Chlorine 50 PPM Comments: Pump Installers Name: Sullivan Water Wells Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Merrill Certified Drilling Log OWNER OF LAND: Hultquist Homes ADDRESS: 13675 Canyon Rd. Anchorage, AK 99516 LEGAL DESCRIPTION Canyon View Estates BLK 1 LT 1 DATE: 12/29/25 PERMIT NUMBER: OSP251426 DATE OF ISSUE: 12/9/25 TAX IDENTIFICATION NUMBER 02102134000 Is well located at approved permit location: Yes No Method of Drilling: air rotary cable tool Depth of Well: 464’ Casing Type: Steel Wall thickness .250 inches Diameter: 6 inches, depth 188 feet Liner type Static Water Level: 170 feet Recovery Rate 1 gpm gph Method of Testing Air Well Intake Opening Type: open end open hole Screened Start feet Stopped Perforations Start feet Stopped Grout Type: Bentonite Volume: 50 Lbs. Depth: from 2 feet, to 42 feet Well Disinfected Upon Completion: yes no Method of Disinfection: Chlorine 50 PPM Comments: Bore Hole Data Depth From To 0 2 Casing Stickup 2 4 Overburden 4 55 Gravel and sand 55 61 Gravel silt sand some water 61 160 Tight silty sand and gravel damp 160 169 Gravel silty sand 169 464 Bedrock hard black with quartz seams Drillers Name: Cole Sullivan (Rev 05/02/) Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 1 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP251426 PID Number: 021-021-34 Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑■ New ❑ Upgrade Name HULTQUIST HOMES, INC. ABSORPTION FIELD ❑ Deep Trench ❑■ Wide Trench F-1 Bed El Mound Site Address 13675 CANYON ROAD ❑ Other Phone Number of Bedrooms Soil Rating depth from original grade 907-522-3204 4 4.0 GPD/SF JTotal 1.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 0.5Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot CANYON VIEW ESTATES, B1, LT1 Fill added above original grade 2.7 Ft. Gravel length 35 Ft. Township Range Section T12N, R2W, S30, SM Gravel width 5 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 175 Ftz 1 N/A Ft. Well 50'+ 50'+ NA NA 25'+ TANK ❑ Septic ❑ S.T.E.P. ❑ Holding Other Manufacturer ORENCO (FAP 2.0) Capacity 1500 Gal. Surface Water 100'+ 100'+ NA NA Material Number of compartments Lot Line 5'+ 10'+ NA NA NA FIBERGLASS 2 Foundation 10'+ 10'+ NA NA LIFT STATION Manufacturer Capacity Remarks AWWTS Gal. Alarm location Electrical installed by PIPE MATERIAL House to tank ABs Fels Tank to D3034 drainfield Installer HULTQUIST HOMES, INC. Drainfield D3034 COIMTD3034 Inspector PES BENCH MARK (Assumed elevation) 49 ft Inspdteeccon est 12/19/25 12/29/25 Location and description 3'd 12/30/25 2nd 4" 2/12/26 See Site Plan, GARAGE FINISH FLOOR ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp A�,4 1k Conditional Approval: Date OF. AWCO� /*• STH * r �,.. •�ev`n R. Pan•^or•e' Septic Syste % �% c;E 8149 �s 87/02/2026. c� Approved Date ES�10h�i� e: this approval does not include well permit requirements. (Rev 05/02/) Lot 1 Lot 2 C A N Y O N R O A D TH-2 (PES 2019) NO W E L L S O R S E P T I C S W / I N 1 0 0 ' 1 1 6 0 VACANT LOT TH-1(PES-2025) 4BR SFD (N) WELL (N) P U E 2 0 1 6 - 0 1 3 1 0 3 - 0 TH-1 (PES 2019) NO WELLS OR SEPTICS W/IN 100' PA V E D D R I V E W A Y ABSORPTION FIELD (N).1500gal ADVANTEX FAP (N) 20 ' T & E E S M T 1 1 5 0 1 1 5 0 1 1 4 0 1 1 3 0 RESERVE AREA CAT III (NIC) B A C FC CO3 MT1 CO2 MT2 1 1 4 0 BM 2 0 ' T & E E S M T D 50' WELL RAD. 100' WELL RAD. 82.0' 92.0' 91.8' 24.2' 81.4'76.8' 69.2' 57.9' 47.8' 44.8' CO1 P. O . B O X 1 8 0 7 P A L M E R , A K 9 9 6 4 5 PA N N O N E E N G I N E E R I N G S E R V I C E S , L L C ( C . I . 1 0 8 8 ) PH O N E ( 9 0 7 ) 7 4 5 - 8 2 0 0 F A X ( 9 0 7 ) 7 4 5 - 8 2 0 1 DA T E SC A L E SH E E T P. I . D . N O PE R M I T N O . DR A W N RE V I S I O N S CH E C K E D MT O RE C O R D D R A W I N G CA N Y O N V I E W E S T A T E S B L O C K 1 L O T 1 CL I N E T : H U L T Q U I S T H O M E S , I N C . SI T E : 1 3 6 7 5 C A N Y O N R O A D AN C H O R A G E , A K 9 9 5 1 6 03 / 1 7 / 2 0 2 6 02 1 - 0 2 1 - 3 4 OS P 2 5 1 4 2 6 AC P ST E V E N R . P A N N O N E CE - 8 1 4 9 R E G I S TEREDPROFE S S I O N A L E N GINEER 03 / 1 7 / 2 0 2 6 SI T E P L A N 1" = 5 0 ' 1 O F 2 NEW SEPTIC DESIGN PARAMETERS PRIMARY/RESERVE SEPTIC SYSTEM NO. BEDROOM: 4(600 gpd) TANK SIZE: 1500gal ADVANTEX FAP W/AX-20 DESIGN PERC RATE: 16-30 MPI SOIL RATING: 4.0 GPD/SF AREA RQD: 150 SF SYS. TYPE: WIDE TRENCH 0.5' E.D. MIN LENGTH: 30.0 LF USE: 35LF x 5.0'W x 0.5' E.D., 1.0' T.D. TOTAL AREA: 175 WATER LINE / WELL RADIUS ESMT/SETBACK STREAM/DRAINAGE WAY CENTERLINE FLOW PATH RECORD DRAWING THIS RECORD DRAWING REPRESENTS THE AS-BUILT CONDITION OF THE PROPERTY IMPROVEMENTS DESCRIBED ABOVE. THE DRAWING AND ANY OTHER SUBSEQUENT ATTACHED OR INCLUDED INFORMATION IS BASED ON PERIODIC VISUAL OBSERVATION BY A REPRESENTATIVE OF PES ALONG WITH NOTES, PHOTOS, AND OTHER INFORMATION PROVIDED BY THE INSTALLER OF THE SYSTEM. THE INFORMATION PROVIDED IN THE RECORD DRAWING APPEARS REASONABLE AND REPRESENTS THAT THE PROJECT WAS DESIGNED AND CONSTRUCTED IN GENERAL CONFORMANCE OF 18 AAC 72, THE ADEC ONSITE WASTEWATER SYSTEM INSTALLATION MANUAL, AND AMC 15.65 WHERE APPLICABLE. PES SHALL NOT BE HELD LIABLE FOR SYSTEM DEFICIENCIES WHICH FALL OUTSIDE THE SCOPE OF THE REQUIRED VISUAL OBSERVATIONS OR SUBSEQUENT OBSERVATIONS IF REQUESTED BY THE INSTALLER. SEPTIC SYSTEM INSTALLERS ARE TRAINED AND APPROVED BY THE MUNICIPALITY OF ANCHORAGE AND OR ADEC AS APPLICABLE. INSTALLERS ARE RESPONSIBLE FOR CONSTRUCTING THE SEPTIC SYSTEM AS DESIGNED AND ENSURING THEIR WORK CONFORMS TO THE CODES AND POLICIES STATED ABOVE. ABBREVIATIONS ADVTX ADVANTEX SYSTEM BM BENCHMARK CO CLEAN OUT NO. (E)EXISTING ESMNT EASEMENT FC FOUNDATION CLEANOUT FND FOUNDATION MT MONITOR TUBE NO. MH MANHOLE NO. (N)NEW NIC NOT IN CONTRACT PL PROPERTY LINE RES FLD RESERVE FIELD TH TEST HOLE SHEET NOTES: 1.WELL LOCATION HEREON IS PER RECORD MEASUREMENT AND DIFFERS FROM LOCATION SHOWN ON PERMITTED DRAWINGS. 12 8 11 10 9 BOH 6 7 5 3 4 2 TH-1 (2025) OR 1 OG: 41.6 13 PROFILE SCALE: NTS MOA SAND TO LEVEL AS NEEDED BM GARAGE FF: 49.00 1500g ADVANTEX FAP FC CO3 CO1 OG/FG: 47.3 MT1 MT2 CO2 FG: 44.7 0.5' DRAIN ROCK 4" DRAIN PIPE FILTER FABRIC BOTTOM OF FIELD: 40.6 INV:41.1 BOTTOM OF FIELD: 40.6 INV:41.1 INV:43.9 TOT: 44.8 SM/GM SM/ML MH1 ADVTX FG: 45.0 *NO WATER OBSERVED P. O . B O X 1 8 0 7 P A L M E R , A K 9 9 6 4 5 PA N N O N E E N G I N E E R I N G S E R V I C E S , L L C ( C . I . 1 0 8 8 ) PH O N E ( 9 0 7 ) 7 4 5 - 8 2 0 0 F A X ( 9 0 7 ) 7 4 5 - 8 2 0 1 DA T E SC A L E SH E E T P. I . D . N O PE R M I T N O . DR A W N RE V I S I O N S CH E C K E D MT O RE C O R D D R A W I N G CA N Y O N V I E W E S T A T E S B L O C K 1 L O T 1 CL I N E T : H U L T Q U I S T H O M E S , I N C . SI T E : 1 3 6 7 5 C A N Y O N R O A D AN C H O R A G E , A K 9 9 5 1 6 03 / 1 7 / 2 0 2 6 02 1 - 0 2 1 - 3 4 OS P 2 5 1 4 2 6 AC P ST E V E N R . P A N N O N E CE - 8 1 4 9 R E G I S TEREDPROFE S S I O N A L E N GINEER 03 / 1 7 / 2 0 2 6 SE P T I C P R O F I L E 1" = N . T . S . 2 O F 2 1 SCALE: N.T.S. SEPTIC SYSTEM PROFILE Permit Number:OSP251426 Tax Code Number:02102134000 Work Type:WellSeptic Initial Effective Date: Design Engineer: Site Legal Address:CANYON VIEW ESTATES BLK 1 LT 1 G:3042 Owner:HULTQUIST HOMES INC Site Mailing Address:13675 CANYON RD, Anchorage Lot Size in Sq Ft:56107 Total Bedrooms:4 This permit is for the construction of: Disposal Field Septic Tank Holding Tank Privy Non-Public Water Well Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On-Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 12/9/2025 12/9/2026 PANNONE ENGINEERING SERVICES Expiration Date: þ þ ¨¨þ ¨ Issued To: Issued By: Date: Date: 12/9/2025 12/9/2025 PANNONE ENGINEERING SERVICES Isatou B Njie MUNICIPALITY OF ANCHORAGE On-Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On-Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE A Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 021-021-34 Property owner(s) Hultquist Homes, Inc. Day phone. Mailing address 12570 Old Seward Highway Anchorage, AK 99515 Site address NHN Canyon Road Legal description CANYON View Estates Block 1 Lot 1 Number of Bedrooms 4 Engineering Firm Pannone Engineering Services, LLC. Building Permit Number A2 S- 5 7(17 Not Applicable r_1 APPLICATION IS FOR: APPLICATION IS AN: (Z all that apply) Disposal Field M Initial F -I Septic Tank El Upgrade ❑ Holding Tank ❑ Renewal ❑ Privy ❑ Well Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Permit/Rush Fees: too Date of Payment: 1117W21 Permit No. 05PAIZIZ� May 2025 Waiver Fees: Date of Payment: Waiver No. Distance: Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com 26 November, 2025 Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, Alaska Subject: Canyon View Estates Block 1 Lot 1 NHN Canyon Road Well & Septic System Permit Request This is a design narrative for a permit to install an initial well and septic system on the subject property. The installation will serve a proposed four (4) bedroom house. This lot and surrounding lots are served by private wells. Currently there are no wells within 100ft of the proposed installation. 1. Soils: A test hole was performed on this lot by Pannone Engineering Services, LLC –in 2019 during the initial subdivision’s development, as well as an additional test hole conducted in 2025. Approximate locations are shown on the attached site plan. Groundwater was not observed during the excavation of TH-1 (PES 2025) to a depth of 12.5’ below ground surface (BGS), and bedrock was not encountered. Groundwater was not observed in the test hole monitor tube after 7-days to a depth of 12.5’ BGS. Based on the results of the percolation test conducted in 2025 and overall soils appearance; an application rate of 4.0 gpd/SF was used for the design of an advanced wastewater treatment system in the area of the newly conducted test hole. 2. Soil Absorption System Design: See design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. 4. Topography: See attached site plan for area topography. 5. Drawing Markings: The Drawings are marked “For MOA Review Only”. When written notification that the review is complete and no further comments are received from MoA On -Site Department, the note will be removed and “For Construction” drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions, please contact me at (907) 745-8200. Sincerely, SRP Steven R. Pannone, P.E. F. ASCE Owner | Principal Engineer 26 November 2025 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251426, Isatou Njie, 12/09/25 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251426, Isatou Njie, 12/09/25 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251426, Isatou Njie, 12/09/25 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251426, Isatou Njie, 12/09/25 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251426, Isatou Njie, 12/09/25 12/9/2025 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: (907)343-7904 On -Site Water &Wastewater Section Fax: (907)343-7997 Parcel ID 021 -021-34 Certificate of On -Site Systems Approval OSC261234 Expiration Date: Legal description CANYON VIEW ESTATES BLK 1 LT 1 Site address 13675 CANYON RD Current property owner(s) HULTQUIST HOMES INC X The On-site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or conditions: i By: - Original Certificate Date: 7/16/2026 This/ certificate—of On -Site Systems Approval (COSA) is intended to demonstrate the subject sy4tem(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Service Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's submittal. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other MUNICIPALITY OF Development Services Department On -Site Water & Wastewater Section -- ANCHORAGE Phone: 907-343-7904 Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 021-021-34 Complete legal description Canyon View B1 L1 Location (site address) 13675 Canyon Rd Current property owner(s) Hultguist Homes 2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS Day phone 3. TYPE OF WATER SUPPLY: ❑■ Private Well serving # 1 dwelling units ❑ Other Non-public well as regulated by MOA ❑ Water Storage ❑ Community Well or Public 4. TYPE OF WASTEWATER DISPOSAL: ❑■ Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel ❑ Plastic ❑ Concrete ■❑ Fiberglass Age new - See advisory if steel or fiberglass older than 20 years 6. ABSORPTION FIELD: ❑■ AWWTS ❑ Bed ❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $D Waiver Fee $ Date of Payment L a Date of Payment COSA # (i S GoZ �' ( 2 3Waiver # COSA Application_Apr2025.doc COSA Checklist_May2025.docx COSA Checklist Legal Description: Parcel ID: If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank Date of pumping Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. DISPOSAL FIELD DATA Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Adequacy test date Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) in Effective depth used in Effective depth remaining in Comments/Deficiencies: E. SEPARATION DISTANCES From Well on Lot to: (Please enter distances if less than required) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Disposal Field on Lot > 100’Yes if No ft Neighboring Disposal Fields > 100’ Yes if No ft Sewer Line/Main > 100’ Yes if No ft Sewer Manhole/Cleanout > 100’ Yes if No ft Sewer Service/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required) Tank to Foundation > 10’ Yes if No ft Field to Foundation > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main/Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER Phone Name of Firm Engineer’s Printed Name COSA Checklist_May2025.docx Date MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this lry14'bay of :9 l.K — of 20. Z (.,by and between CMA0 CaiAe. fn + DOY'c (kjherein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as AdvanteX located at (legal description) Canyon View Estates Lot 1 Block 1 2. Maintenance Repairs and Alterations. (Owner is required to read, understand and initial each section) bL C 'C,' Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. VL CG It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). by C C Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. OL� CG Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Pagel of 3 PC -L4— Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. p < < G Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. C� Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. p�- CG Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. C Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. s (rev. 05/18/2018) Page 2 of 3 OWNER: By: (signature) Date: 6 Z� l 0.Y�n CaO e061 ��-t (P�t name) STATE OF ALASKA ) ss. THIRD JUDICIAL DISTRICT ) The foregoing instrument was acknowledged before me this li�"day of Jv tXA , 202-11, byCw✓t� o Cr�.t.r�t 4i -D. QV90ng CkSjVv.(G NOTARY PUB 1C FOR ASKA .STATE OF ALASKA NOTARY PUBLIC My Commission expires: _,6 (?,21,d?ib Ashlee LaVigne (signature) Date: ;print name) Title: (rev. 05/18/2018) Page 3 of 3 Lot 1, Block 1, Canyon View Estates Subdivision Asbuilt Land Surveying Land Development Consultants Subdivision Specialists Construction Surveying AEC# 173042 S4 Group 610 E 5th Avenue Anchorage, Alaska 99501 (907) 306-8104 mail@S4AK.com 0 50' GRAPHIC SCALE 0 30' GRAPHIC SCALE 1" = 30' 5/25/2026