Loading...
HomeMy WebLinkAboutJB CRUZ LT 1BOnsite File Formerly Illiamna Acres Tract 9 N2 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP251326 Work Type: WellSeptic Initial Tax Code Number: 01710152000 Site Legal Address: JB CRUZ LT 1 G:3037 Site Mailing Address: 14001 BUFFALO ST, Anchorage Owner: SEIDL PATRICK ALASKA COMMUNITY Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: c�1�nt r� t)l�Y,al'Cltle:tti 9/24/2025 9/24/2026 84834 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: This permit is for proposed lot 1 B as part of a subdivision of JB CRUZ LT 1. The proposed fields are to meet separation to the proposed new property line. Proposed Lot 1A: need to justify alternate site for wastewater system for this property. Need to justify that wastewater system meets separation to proposed boundary lines. Received By:i Date: Issued By: Date: "% y 0 3 MUNICIPALITY OF ANCHORAGE 4ge" Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 017-101-52 Property owner(s) Patrick Seidl Day phone (907) 242-1127 Mailing address 14001 Buffalo St, Anchorage, AK 99516 Site address 14001 Buffalo St, Anchorage, AK 99516 Legal description JB Cruz Lot 1 Number of Bedrooms 3 Engineering Firm Forge Engineering Building Permit Number Not Applicable RN APPLICATION IS FOR: APPLICATION IS AN: (Z all that apply) Absorption Field Initial Septic Tank Upgrade ❑ Holding Tank ❑ Renewal ❑ Privy EJ Well R THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Permit/Rush Fees: Date of Payment: Permit No. 02 1 No Waiver Fees: Date of Payment: Waiver No. Distance: September 10, 2025 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: JB Cruze Lot 1B – 14001 Buffalo St Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 3-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot has very mild slopes, near the front is where the new septic system is located. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251326, Curtis Townsend, 09/24/25 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=30 ' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND JB CRUZ, LOT 1B FEET 0 30 60 SEPTIC PLAN 9/10/25 TH#1 3-BDRM HOME 10 ' U T I L I T Y E A S E M E N T 20' T&E EASEMENT 30' ACCESS EASEMENT (2) 45' LONG x 5' WIDE, 0.5' EFFECTIVE DEPTH ABSORPTION TRENCH MT MUST BE WITHIN 1' OF THE ENDS OF THE TRENCH ALTERNATE SITE CAT III 15' LONG X 5' WIDE 0.5' EFFECTIVE DEPTH 1250-GAL STEP TANK FCO MT MT EXISTING SEPTIC PROPOSED WELL WELL RADIUS 460 455 455 455 455 450 450 465 460 455 MT MT Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251326, Curtis Townsend, 09/24/25 JB CRUZ , LOT 1B TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 5' DESIGN FACTORS:SYSTEM REQUIREMENTS: 450 GPD PEAK FLOW PERK RATE: 0.87 MIN/IN APPLICATION RATE: 1.0 GPD/SF 5' WIDE TRENCH SYSTEM 1250 GAL STEP TANK BOTTOM OF TRENCH: 0.5' BELOW GRADE FLOW LINE ELEVATION: AT GRADE 450 GPD / 1.0 GPD/SF / 5' WIDE *1.00 RED FACTOR [0.5' DEEP] = 90 LF TRENCH REQUIRED (90 LF SPECIFIED) 9/10/25 2' 6" 2'-6" 6" DRAINFIELD ROCK GEOTEXTILE FABRIC PROVIDE ADDITIONAL FILL TO ACCOUNT FOR SETTLEMENT 2" FOAM INSULATION MOA APPROVED SAND EACH TRENCH 11 4" PVC w/ 20 - 1 8" ORIFICES EVENLY SPACED @ 2.25' OC 3:1 SLOPE W/ TOPSOIL & SEEDED Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251326, Curtis Townsend, 09/24/25 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING DEPTH TO WATER AFTER MONITORING 0.87 8/26/25 1 2 3 4 5 6 GP (POORLY GRADED SAND w/ SOME GRAVEL) Professional Engineers Stamp: JB Cruz Lot 1 8/26/25 017-101-52 Patrick Seidi 53 8 16 1.5' OB 4:17 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: JARED E 59 8 16 6.5 9/2/25 COMMENTS: SITE PLAN 6 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED EXCEPT WHERE NOTED. 9/10/25 MOISTURE NOTED AT TIME OF DIGGING?yes 53 8 165:00 59 8 16 6 53 8 165:10 59 8 16 6 53 8 165:15 59 8 16 6 53 8 165:15 59 8 16 6 53 8 165:15 59 8 16 6 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251326, Curtis Townsend, 09/24/25