Loading...
HomeMy WebLinkAboutRICLIN LT 6Permit Number:OSP261006 Tax Code Number:05153143000 Work Type:Well Initial Effective Date: Design Engineer: Site Legal Address:RICLIN LT 6 G:1462 Owner:GROSKREUTZ NOAH G Site Mailing Address:24885 ANNIE PEARL CIR, Chugiak Lot Size in Sq Ft:47701 Total Bedrooms:2 This permit is for the construction of: Disposal Field Septic Tank Holding Tank Privy Non-Public Water Well Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On-Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 2/6/2026 2/6/2027 PANNONE ENGINEERING SERVICES Expiration Date: ¨¨¨¨þ ¨ Issued To: Issued By: Date: Date: 2/6/2026 2/6/2026 PANNONE ENGINEERING SERVICES Isatou B Njie MUNICIPALITY OF ANCHORAGE On-Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On-Site Water System Permit Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com Mailing: P.O. Box 1807 Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, Alaska 99519 Subject: Riclin Lot 6 Initial Well Permit Request This is a design narrative for a permit to install a private well for this property. Currently the lot is primarily undeveloped. This lot and the surrounding lots are to be served by private well and septic. Currently there are no sewer mains or private septic systems within 100’ of the proposed well location. 1. Well Design. The well will be located: 100’+ from any sewer main and or sewer system manhole . 100’+ from any on-site septic system. 25’+ from any private sewer lines and or clean outs. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions or concerns, please contact me at (907) 745 -8200. Sincerely, SRP Steven R. Pannone, PE, F. ASCE Owner/Civil Engineer 6 January, 2026 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261006, Isatou Njie, 02/06/26 E E SEPTIC AREA 465 475 470 465 460455 450 480 475 470 470 480 470 470 RICLIN LOT 8 RICLIN LOT 7 RICLIN LOT 5 RI C L I N L O T 9 RICLIN LOT 2 RICLIN LOT 3 TONJESS ESTATES BLOCK 3 LOT 10 ANNI E P E A R L CIRCL E VACANT LOT (NO WELL OR SEPTIC) STORAGE BLDG. (P) 56' x 128' (BY OTHERS)103.0' (100.0' MIN.) 10.3' 12.8' RICLIN LOT 6 NO SEPTIC W/IN 100' OF PROPOSED WELL NO SEPTIC W/IN 100' OF PROPOSED WELL STORAGE BLDG. (P) 56' x 128' (BY OTHERS) NO SEPTIC W/IN 100' OF PROPOSED WELL 27.3' OFFICE (E) FENCE (E) UTIL. & PRIVATE ACCESS ESMT SHARED PRIVATE WELL (E) WELL (E) A S SUMED DRI VEWAY AR EAASSUMED DRIVEWAY AREA WELL (P) (SEE NOTES) 6' x 14' FUTURE BATHROOM ADDN. (P) (BY OTHERS) APPROXIMATE SECONDARY DRIVEWAY ROUTE (E) (ACCESS FROM LOT 3) (PER OWNER) (LOT OWNED BY SUBJECT PROPERTY OWNER) APPROX. LOCATION PLANTER & LARGE SPRUCE TREE (E) ASSUMED ROUTE WATER SERVICE LINE (BY OTHERS) RAN BEHIND SEWER SERVICE RLS TO STAKE LOCATION & RADIUS PRIOR TO CONSTRUCTION 25' LANDSCAPE BUFFER ESMT ASSUMED ROUTE WATER SERVICE LINE (BY OTHERS) WELL (E) 25 ' L A N D S C A P E BU F F E R E S M T ASSUMED ROUTE WATER SERVICE LINE (BY OTHERS) RAN BEHIND SEWER SERVICE ASSUMED ROUTE WATER SERVICE LINE (BY OTHERS) RAN BEHIND SEWER SERVICE SEPTIC LOCATION (P) UNDER ADEC APPROVAL TO CONSTRUCT REQUEST FLOOR DRAIN WASTE COLLECT/RV DUMP STATION LOCATION (P) UNDER ADEC APPROVAL TO CONSTRUCT REQUEST APPROX. LOCATION BATHROOM (P) (BY OTHERS) P. O . B O X 1 8 0 7 P A L M E R , A K 9 9 6 4 5 PA N N O N E E N G I N E E R I N G S E R V I C E S , L L C ( C . I . 1 0 8 8 ) PH O N E ( 9 0 7 ) 7 4 5 - 8 2 0 0 F A X ( 9 0 7 ) 7 4 5 - 8 2 0 1 DA T E SC A L E SH E E T P. I . D . N O PE R M I T N O . DR A W N RE V I S I O N S CH E C K E D LJ C FO R C O N S T R U C T I O N RI C L I N L O T 6 OW N E R : N O A H G . G R O S K R E U T Z SI T E : 2 4 8 8 5 A N N I E P E A R L C I R C L E CH U G I A K , A K 9 9 5 6 7 01 / 0 6 / 2 0 2 6 05 1 - 5 3 1 - 4 3 OS P X X X X X X AC P RE V 1 : 0 2 / 0 3 / 2 0 2 6 01 / 0 7 / 2 0 2 6 ST E V E N R . P A N N O N E CE - 8 1 4 9 R E G I STEREDPROFESSI ONA L ENGINEER SI T E P L A N 1" = 5 0 ' 1 O F 2 SEPTIC WATER LINE / WELL RADIUS ESMT/SETBACK PLEASE REFER TO THE NOTES AND SPECIAL PROVISIONS PAGE FOR MORE INSPECTION INFORMATION. PES SHALL NOT BE HELD LIABLE FOR INSTALLATIONS NOT MEETING THE REQUIREMENTS OF 18 AAC 72 AND/OR AMC 15.55 AND THE SPECIAL PROVISIONS OF THIS PERMIT AS APPLICABLE IF THE CONTRACTOR AND OR PROPERTY OWNER FAIL TO GIVE PES PROPER NOTICE. PES WILL ATTEMPT TO DOCUMENT THE SYSTEM AND OBTAIN ANY NECESSARY WAIVERS AT THE CONTRACTOR AND OR PROPERTY OWNERS EXPENSE. PES MAKES NO GUARANTEES THAT ANY NEEDED SEPARATION DISTANCES WAIVERS WILL BE APPROVED BY ADEC OR THE MUNICIPALITY OF ANCHORAGE ONSITE DEPARTMENT STAFF. ABBREVIATIONS (E) EXISTING (F) NEW NIC NOT IN CONTRACT (P) PROPOSED TYP TYPICAL WELL NOTES: 1. FINAL WELL LOCATION TO MAINTAIN AT LEAST 25 FEET FROM THE ON PROPERTY SEWER SERVICE LINES AND FOUNDATION CLEANOUTS. 2. THE LOCATION OF FEATURES SHOWN ON THIS DRAWING ARE IN ACCORDANCE WITH THE MOST RECENT SURVEY PLOT-PLAN PERFORMED BY BLUE ARROW SURVEYS ON 10/15/2025 AND ADDITIONAL INFORMATION AND DIRECTION GIVEN BY THE PROPERTY OWNER. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261006, Isatou Njie, 02/06/26 P. O . B O X 1 8 0 7 P A L M E R , A K 9 9 6 4 5 PA N N O N E E N G I N E E R I N G S E R V I C E S , L L C ( C . I . 1 0 8 8 ) PH O N E ( 9 0 7 ) 7 4 5 - 8 2 0 0 F A X ( 9 0 7 ) 7 4 5 - 8 2 0 1 DA T E SC A L E SH E E T P. I . D . N O PE R M I T N O . DR A W N RE V I S I O N S CH E C K E D LJ C FO R C O N S T R U C T I O N RI C L I N L O T 6 OW N E R : N O A H G . G R O S K R E U T Z SI T E : 2 4 8 8 5 A N N I E P E A R L C I R C L E CH U G I A K , A K 9 9 5 6 7 01 / 0 6 / 2 0 2 6 05 1 - 5 3 1 - 4 3 OS P X X X X X X AC P RE V 1 : 0 2 / 0 3 / 2 0 2 6 01 / 0 7 / 2 0 2 6 ST E V E N R . P A N N O N E CE - 8 1 4 9 R E G I STEREDPROFESSI ONA L ENGINEER NO T E S NO S C A L E 2 O F 2 1. GENERAL NOTES: 1.1. ANY MODIFICATIONS TO THE ATTACHED PLANS NEED TO BE APPROVED BY PES AND THE OWNER OF THE PROPERTY. 1.2. PES SHALL BE NOTIFIED A MINIMUM OF 48 HOURS IN ADVANCE BEFORE CONSTRUCTION OF THE PROPOSED WASTEWATER TREATMENT SYSTEM. 1.3. PES SHALL BE NOTIFIED A MINIMUM OF 24 HOURS IN ADVANCE TO PERFORM A MINIMUM OF FOLLOWING INSPECTIONS: 1.3.1. A PRE CONSTRUCTION MEETING IS REQUIRED BY STATE AND MUNICIPAL REGULATIONS BEFORE A ONSITE WASTEWATER TREATMENT SYSTEM MAY BE INSTALLED. 1.3.2. TOP OF SEPTIC AND OR HOLDING TANK (TANK IS SET IN PLACE LEVEL WITH ALL PIPING ATTACHED (CLEANOUTS, MANHOLES, INLET AND OUTLET PIPING). 1.3.3. BOTTOM OF EXCAVATION OF THE DRAIN FIELD/S. 1.3.4. AFTER PLACEMENT OF FILTER SAND (IF NEEDED). 1.3.5. AFTER INSTALLATION OF THE DRAIN ROCK WITH ALL ASSOCIATED PIPING IN PLACE INCLUDING DISTRIBUTION LINES CLEANOUTS AND MONITOR TUBES PRIOR TO INSTALLATION OF FILTER FABRIC AND INSULATION (IF NEEDED). 1.3.6. FINAL GRADE INSPECTION. ENTIRE SYSTEM IS INSTALLED AND BACKFILLED. 1.4. THE ENGINEER (PES) HAS NO CONTRACTUAL RELATIONSHIP WITH THE CONTRACTOR (THE INSTALLER OF THE SYSTEM) AND, THEREFORE, HAS NO AUTHORITY, CONTROL OR RESPONSIBILITY FOR THE CONTRACTOR'S EMPLOYEES, THE QUALITY OF WORK, THEIR COMPLIANCE WITH THE DESIGN DRAWINGS/SPECIFICATIONS OR THEIR MEANS/METHODS OF CONSTRUCTION. AT APPROPRIATE INTERVALS, THE ENGINEER WILL VISIT THE WORKSITE TO OBSERVE THE QUALITY OF THE CONSTRUCTION AND TO DETERMINE IN GENERAL IF THE CONSTRUCTION IS PROCEEDING IN ACCORDANCE WITH THE DESIGN DRAWINGS/SPECIFICATIONS.THE ENGINEER WILL NOTIFY THE OWNER IF DEFICIENCIES ARE OBSERVED; HOWEVER, THE FAILURE OF THE ENGINEER TO OBSERVE A DEFICIENCY WILL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY FOR CORRECTING ANY SUCH DEFICIENCY. THE ENGINEER WILL PREPARE RECORD DRAWINGS AND SUBMIT THEM TO THE REGULATORY AGENCY HAVING JURISDICTION OVER THE WASTEWATER TREATMENT SYSTEM (ADEC OR MOA). FINAL APPROVAL OF THE WORK AND CORRECTION OF ANY DEFICIENCIES IS BETWEEN THE OWNER, THE CONTRACTOR, AND THE REGULATORY AGENCY HAVING JURISDICTION OVER THE WASTEWATER TREATMENT SYSTEM (ADEC OR MOA). 2. SCOPE AND SPECIFICATIONS: 2.1. ALL CONSTRUCTION SHALL BE AS SPECIFIED IN THE ATTACHED PLANS. CONSTRUCTION ACTIVITIES SHALL ALSO BE IN ACCORDANCE WITH THE MOST CURRENT EDITION OF THE FOLLOWING CODES AND POLICIES AS APPLICABLE. 2.1.1. 18 AAC 72 2.1.2. AMC 15.65 2.1.3. AMC 15.55 2.1.4. MOA STANDARD SPECIFICATION FOR COMPONENTS PARTS AND MATERIALS. 2.1.5. ADEC ONSITE WASTEWATER SYSTEMS INSTALLATION MANUAL (OWSIM). 2.1.6. MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS). 2.2. SCOPE OF WORK: INSTALL PRIVATE WELL IN ACCORDANCE WITH THE ATTACHED DESIGN AND SPECIFICATIONS. 2.3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF -- FEET BELOW EXISTING GRADE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN -- FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. 2.4. STRUCTURES DEPICTED ON THE SITE PLAN ARE BASED UPON ONE OF THE FOLLOWING: CONCEPTUAL PLOT PLAN DEVELOPED BY OWNER; A PLOT PLAN DEVELOPED BY RLS; OR A SURVEY AS-BUILT. 3. CONSTRUCTION SPECIFICATIONS: 3.1. ALL EXCAVATION DEPTHS ARE ADVISORY. THEY ARE TO BE VERIFIED AND MAY BE MODIFIED BY THE ENGINEER IF ACTUAL FIELD CONDITIONS VARY FROM THOSE USED TO PREPARE THE DESIGN 3.2. EXCAVATE THE DRAIN FIELD. BOTTOM OF EXCAVATION SHALL BE LEVEL AND SCARIFIED. RECORD ELEVATIONS AT BEGINNING, MIDDLE AND END OF TRENCH BOTTOM. CONSTRUCTION EQUIPMENT SHALL NOT OPERATE ON THE FLOOR OF THE EXCAVATION. ANY MATERIAL COMPACTED BY THE OPERATION OF THE CONSTRUCTION EQUIPMENT SHALL BE REMOVED AND REPLACED WITH NON-COMPACTED MATERIAL. 3.3. PLACE THE SEWER ROCK TO THE SPECIFIED DEPTHS. DO NOT CONTAMINATE SEWER ROCK WITH NATIVE MATERIAL OR SPOILS FROM EXCAVATION. LEVEL ROCK SURFACE TO ±1" PRIOR TO INSTALLING THE PERFORATED PIPE. 3.4. ALL PIPE SHALL BE SCHEDULE 40 ABS AND OR PVC CONFORMING TO ASTM F628 AND ASTM D3034 AS APPLICABLE OR ENGINEER APPROVED EQUAL. 3.4.1. ALL PRESSURIZED SEWER LINES SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC CONFORMING TO ASTM D1785 OR ENGINEER APPROVED EQUAL 3.5. FOR MOA PROJECTS THE MINIMUM SOIL COVER SHALL BE 3 FEET OVER SEWER LINES AND DRAIN FIELDS AND 4 FEET OVER THE SEPTIC TANK. ONE INCH OF INSULATION MAY BE SUBSTITUTED FOR 1 FOOT OF SOIL COVER. 3.6. FOR STATE OF ALASKA (ADEC) PROJECTS THE REQUIRED SOIL COVER IF 4 FEET FOR ALL WASTEWATER SYSTEM COMPONENTS. 3.7. THE MINIMUM ALLOWABLE SOIL COVER SHALL OVER ANY WASTEWATER SYSTEM COMPONENT SHALL BE 2 FEET WITH 2 INCHES OF APPROVED INSULATION. 3.8. ALL INSULATION SHALL BE 2" THICK DOW HI-40 INSULBOARD OR ENGINEER APPROVED EQUAL. CENTER INSULBOARD WIDTH OVER SEPTIC TANK, DRAIN FIELD, OR SEWER LINES. 3.9. GEOTECHNICAL FABRIC SHALL BE TYPAR 3401 OR ENGINEER APPROVED EQUAL. LAP ALL JOINTS 2 FEET MINIMUM. GEOTECHNICAL FABRIC SHALL CONFORM TO AASHTO M288 CLASS 3 AND HAVE THE FOLLOWING CHARACTERISTICS: 3.9.1. MINIMUM PERMITTIVITY (ASTM D4491) -0.5/sec 3.9.2. MAXIMUM APPARENT OPENING SIZE (ASTM D4751) - 0.20 TO 0.21mm (US SIEVE #70) 3.10. COVER THE DISTRIBUTION PIPE WITH A MINIMUM OF 2" OF SEWER ROCK AND COVER WITH GEOTEXTILE BEFORE PLACING INSULATION AND BACKFILL. 3.11. MATERIAL USED AS FILL SHALL BE CLEAN AND FREE OF ORGANICS, TRASH AND CONSTRUCTION DEBRIS. 3.12. SLOPE ALL FILL MATERIAL TO DRAIN AT 2% MINIMUM SLOPE AND 3:1 MAXIMUM SLOPE AND IN SUCH A MANNER THAT PONDING AT OR NEAR THE DRAIN FIELD DOES NOT OCCUR. THE FILL SHALL BE LEFT AT 6" HIGHER THAN SHOWN TO ALLOW FOR SETTLEMENT. SEED SURFACE AFTER COMPLETING INSTALLATION AS PER MOA CODE. 3.13. RECORD THE FINISH GROUND ELEVATION OVER THE BEGINNING, MIDDLE AND END OF SYSTEM. 3.14. MAINTAIN 5' SEPARATION BETWEEN PERCOLATION HOLE AND THE DRAIN FIELD TRENCH. 3.15. EXPOSE, PUMP AND FILL LOG DISPOSAL CRIB OR CONCRETE TANK WITH SOIL TO ABANDON IAW WITH MOA CODE IF NEEDED. NOTES & SPECIAL PROVISIONS: 4. CONTRACTOR RESPONSIBILITIES: 4.1. THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE SITE CONDITIONS AND LOCATIONS OF ALL LOT LINES, EASEMENTS, WELLS (E & P), SEPTIC SYSTEMS (E & P) AND SHALL MEET MINIMUM SEPARATION DISTANCES OR AS NOTED. 4.2. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK. 4.3. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED. 4.4. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES. 4.5. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE ENGINEER. 4.6. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN. 4.7. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED-LINE AS-BUILT DRAWINGS TO THE ENGINEER. THE RED-LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND TANK ELEVATIONS. 4.8. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN-OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING. 5. THE CONTRACTOR SHALL CERTIFY THAT ALL WORK WILL BE PERFORMED IN ACCORDANCE WITH THE APPROVED PERMIT, AND ANY AND ALL CHANGE ORDERS, AND THAT THE AS-BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED. BY ACCEPTANCE AND CONSTRUCTION OF THE ATTACHED PLANS THE OWNER, CONTRACTOR AND APPLICABLE REGULATORY AGENCY AGREE TO THE PROVISIONS SET FORTH ON THIS PAGE AS APPLICABLE AND ANY SUBSEQUENT SPECIFICATIONS (IF ATTACHED). ANNIE P E A R L CIRCLE RICLIN SUBD I V I S I O N Taylor L. Dosch No. 189892 R E GISTEREDPROFESSIO N A L L A N D S U R VEYOR