ON-SITE WASTEWATER INSPECTION REPORT
Permit Number:___________PID Number:___________
Dwelling:Single Family (SF)with ADU Duplex (D)Two Single Family Project:New Upgrade
Name ABSORPTION FIELD
Site Address
Deep Trench Wide Trench Bed Mound
Other
Phone
Number of Bedrooms Soil Rating Total depth from original grade
GPD/SF Ft.
LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe
Subdivision Block Lot Ft.Ft.
Fill added above original grade Gravel length
Township Range Section Ft.Ft.
Gravel width Beds: Number of Lines Distance between lines
SEPARATION DISTANCES Ft.Ft.
From
To Septic
Tank
Absorption
Field Lift Station Holding
Tank
Sewer
Line
Total absorption area Number of trenches Dist. between trenches
Ft2 Ft.
Well TANK Septic S.T.E.P. Holding Other
Manufacturer Capacity
Surface Water
NA
Gal.
Material Number of compartments
Lot Line
Foundation LIFT STATION
Manufacturer Capacity
Gal.Remarks
Alarm location Electrical installed by
Installer PIPE MATERIAL House to tank Tank to
drainfield
Drainfield CO/MT
Inspector BENCH MARK (Assumed elevation)ft
Inspection
dates:1st 2nd Location and description
3rd 4th
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Conditional Approval:Date
Septic System
Approved ____________________________Date
Note: this approval does not include well permit requirements.
(Rev 05/02/18)
1 1
OSP261035 051-103-28
POWELL FRIENDSHIP TRUST
22728 FRIENDSHIP LN, CHUGIAK
(360) 739-8638 5 1.0 T1: 3.1, T2 3.1**
T1: 2.6, T2: 2.6
T1: 0.5, T2: 0.5
55
T1: 0.2, T2: 0.2 T1: 76.3, T2: 76.415N1W 9
5.0
763.5 2 6.4+
100'+100'+25'+
100'+100'+Infiltrator 1530
5'+ 10'+
HDPE 2
10'+ 10'+
*6-8-26, 6-16-26
**bottom of rock, 2' sand liner below
3034 3034
3034 3034RPC – Richard Person Const.
Crewdson Engineering LLC 100
5-26-26 5-27-26
5-29-26 6-5-26*Door threshold at "BM" on record drawing
7/16/2026
Depth
(Feet)
1-
2-
3-
4-
5-
6-
7-
8-
9-
10-
11-
12-
13-
14-
19-
20-
FT AND FT
I
Performed For:
Legal Description:
15-
16-
PERC HOLE DIAMETER
Date Gross Time
Slope Site Plan
PERCOLATION RATE (minutes/inch)
Net Time Depth to Water Net DropReading
COMMENTS
TEST RUN BETWEEN
17-
18-
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
CERTIFY THAT THIS TEST WASPERFORMED BY:
(907)343-7904
Soils Log - Percolation Test
Township, Range, Section:
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT DEPTH?
S
L
O
P
E
Date:
Depth to Water After
Monitoring?
Date Performed:
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Section
4700 Elmore St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
Permit Number:OSP261035
Tax Code Number:05110328000
Work Type:Septic Upgrade
Effective Date:
Design Engineer:
Site Legal Address:T15N R1W SEC 9 LT 55 G:1358
Owner:POWELL FRIENDSHIP TRUST
Site Mailing Address:22728 FRIENDSHIP LN, Chugiak
Lot Size in Sq Ft:108900
Total Bedrooms:5
This permit is for the construction of:
Disposal Field Septic Tank Holding Tank Privy
Non-Public
Water Well Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Coodinate with On-Site staff regarding preferred method.
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
4/13/2026
3/27/2027
Special Provisions: The entire subsurface disposal field and/or alternate is not within a 30 foot
radius of a percolation test. The Engineer needs to do an additional percolation test prior to
the construction of the septic field. Please submit stamped and signed results with the As-
built Inspection Report. If the results require a design change, construction of the system will
stop pending On-Site review and approval.
Expiration Date:
þ þ ¨¨¨¨
Issued To:
Issued By:
Date:
Date:
4/13/2026
4/13/2026
POWELL FRIENDSHIP TRUST
Isatou B Njie
MUNICIPALITY OF ANCHORAGE
On-Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On-Site Wastewater Disposal System Permit
James Jay Crewdson, P.E
Email: CELLC.1@outlook.com
Cell/Text: (907) 280‐9493
PO Box 671389 ● 18368 Amonson Road ● Chugiak, Alaska 99567
April 8, 2026
Municipality of Anchorage
On‐site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99519‐6650
Attention: Plan Reviewer
Reference: T15N, R1W, S9, Lot 55
Septic System Upgrade
Design Narrative
The owner is preparing the subject property to be put on the market for sale in 2026. The existing
undocumented septic system needs to be upgraded. The existing septic tank and drainfield will be
decommissioned in accordance with the code. The proposed septic system will be located at the toe of a
steep slope outside of the 100‐foot well radius.
The proposed 5‐bedroom septic system upgrade is detailed on the design drawings. If constructed as
designed, it will;
Satisfy all code required separation distances,
Not cause any probable adverse impacts to adjacent properties,
Not negatively impact existing wells and septic systems on adjacent properties,
Not be adversely affected by potential drainage that could flow onto and off of the subject
property.
Please feel free to contact me for more discussion.
Thanks
James Jay Crewdson, P.E.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP261035, Isatou Njie, 04/13/26
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP261035, Isatou Njie, 04/13/26
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP261035, Isatou Njie, 04/13/26
COSA Checklist_May2025.docx
COSA Checklist
Legal Description: Parcel ID:
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled Total depth ft
Cased to ft
Sanitary seal is functioning correctly
Wires are properly protected
ft.
Well production at time of test gpm
Water storage tank volume gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in septic tank
Date of pumping
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. DISPOSAL FIELD DATA
Which system tested (date installed)
ALL standpipes present per record drawing
Total measured depth from grade ft (max)
Measured depth to pipe invert from grade ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes go to bottom of effective.
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months)
If yes, enter date
Adequacy test date
Results Pass
Fluid depth prior to test in
Water added gal
New fluid depth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) in
Effective depth used in
Effective depth remaining in
Comments/Deficiencies:
T15N, R1W, S9, Lot 55 051-103-28
5+
6-6-1960 164 0
164
0.954
Crewdson Engineering
Casing height (above ground) 24+ in.
Date of flow test for COSA 6-1-2026
Static water level at beginning of test 55*4-24-2026
Static water level fluctuated between 55' and 60' during flow test, returned to 55' in 15-seconds.
*
*
*New septic system
6-8-2026
3.3
2.8
*
*not required
6
0
6
*new septic system
*
COSA Checklist_May2025.docx
E. SEPARATION DISTANCES
From Well on Lot to: (Please enter distances if less than required)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Disposal Field on Lot > 100’ Yes if No ft
Neighboring Disposal Fields > 100’
Yes if No ft
Sewer Line/Main > 100’ Yes if No ft
Sewer Manhole/Cleanout > 100’
Yes if No ft
Sewer Service/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required)
Tank to Foundation > 10’ Yes if No ft
Field to Foundation > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main/Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm Phone
Engineer’s Printed Name Date
✔✔
✔✔
✔✔
✔
✔
✔✔
✔✔
✔
✔✔
✔✔
✔
Crewdson Engineering, LLC (907) 280-9493
James Crewdson 6-29-2026
Received Date/Time 04/24/2026 10:05
04/24/2026 9:30Collected Date/Time
1261485001
Matrix
SGS Ref.#
Client Sample ID Hose Bib
Client Name
Project Name/#
Printed Date/Time 05/04/2026 16:53Crewdson Engineering LLC
Technical Director Stephen C. Ede
22728 Friendship Lane
Drinking Water
Sample Remarks:
Parameter Results LOQ Units Method
Allowable
Limits
Prep
Date
Analysis
Date InitContainer ID
Metals by ICP/MS
HBL04/30/26EP200.8ug/LArsenic 04/29/26ND5.00 (<10)B
Waters Department
DAT05/01/26SM21 4500NO3-Fmg/LTotal Nitrate/Nitrite-N 0.954 0.200 (<10) C
Microbiology Laboratory
M.A04/24/26SM21 9223B100mLE. Coli Negative 1 A
M.A04/24/26SM21 9223B100mLTotal Coliform Negative 1 A
2 of 5