Loading...
HomeMy WebLinkAboutT15N R1W SEC 9 LT 55Onsite File T15N R1W SEC 9 LOT 55 PID# 051-103-28 Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number:___________PID Number:___________ Dwelling:Single Family (SF)with ADU Duplex (D)Two Single Family Project:New Upgrade Name ABSORPTION FIELD Site Address Deep Trench Wide Trench Bed Mound Other Phone Number of Bedrooms Soil Rating Total depth from original grade GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot Ft.Ft. Fill added above original grade Gravel length Township Range Section Ft.Ft. Gravel width Beds: Number of Lines Distance between lines SEPARATION DISTANCES Ft.Ft. From To Septic Tank Absorption Field Lift Station Holding Tank Sewer Line Total absorption area Number of trenches Dist. between trenches Ft2 Ft. Well TANK Septic S.T.E.P. Holding Other Manufacturer Capacity Surface Water NA Gal. Material Number of compartments Lot Line Foundation LIFT STATION Manufacturer Capacity Gal.Remarks Alarm location Electrical installed by Installer PIPE MATERIAL House to tank Tank to drainfield Drainfield CO/MT Inspector BENCH MARK (Assumed elevation)ft Inspection dates:1st 2nd Location and description 3rd 4th ON-SITE WATER AND WASTEWATER SECTION APPROVAL Conditional Approval:Date Septic System Approved ____________________________Date Note: this approval does not include well permit requirements. (Rev 05/02/18) 1 1 OSP261035 051-103-28 POWELL FRIENDSHIP TRUST 22728 FRIENDSHIP LN, CHUGIAK (360) 739-8638 5 1.0 T1: 3.1, T2 3.1** T1: 2.6, T2: 2.6 T1: 0.5, T2: 0.5 55 T1: 0.2, T2: 0.2 T1: 76.3, T2: 76.415N1W 9 5.0 763.5 2 6.4+ 100'+100'+25'+ 100'+100'+Infiltrator 1530 5'+ 10'+ HDPE 2 10'+ 10'+ *6-8-26, 6-16-26 **bottom of rock, 2' sand liner below 3034 3034 3034 3034RPC – Richard Person Const. Crewdson Engineering LLC 100 5-26-26 5-27-26 5-29-26 6-5-26*Door threshold at "BM" on record drawing 7/16/2026 Depth (Feet) 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 19- 20- FT AND FT I Performed For: Legal Description: 15- 16- PERC HOLE DIAMETER Date Gross Time Slope Site Plan PERCOLATION RATE (minutes/inch) Net Time Depth to Water Net DropReading COMMENTS TEST RUN BETWEEN 17- 18- PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: CERTIFY THAT THIS TEST WASPERFORMED BY: (907)343-7904 Soils Log - Percolation Test Township, Range, Section: WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? S L O P E Date: Depth to Water After Monitoring? Date Performed: Municipality of Anchorage Development Services Department On-Site Water and Wastewater Section 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite Permit Number:OSP261035 Tax Code Number:05110328000 Work Type:Septic Upgrade Effective Date: Design Engineer: Site Legal Address:T15N R1W SEC 9 LT 55 G:1358 Owner:POWELL FRIENDSHIP TRUST Site Mailing Address:22728 FRIENDSHIP LN, Chugiak Lot Size in Sq Ft:108900 Total Bedrooms:5 This permit is for the construction of: Disposal Field Septic Tank Holding Tank Privy Non-Public Water Well Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On-Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 4/13/2026 3/27/2027 Special Provisions: The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a percolation test. The Engineer needs to do an additional percolation test prior to the construction of the septic field. Please submit stamped and signed results with the As- built Inspection Report. If the results require a design change, construction of the system will stop pending On-Site review and approval. Expiration Date: þ þ ¨¨¨¨ Issued To: Issued By: Date: Date: 4/13/2026 4/13/2026 POWELL FRIENDSHIP TRUST Isatou B Njie MUNICIPALITY OF ANCHORAGE On-Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On-Site Wastewater Disposal System Permit James “Jay” Crewdson, P.E Email: CELLC.1@outlook.com Cell/Text: (907) 280‐9493 PO Box 671389 ● 18368 Amonson Road ● Chugiak, Alaska 99567 April 8, 2026 Municipality of Anchorage On‐site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99519‐6650 Attention: Plan Reviewer Reference: T15N, R1W, S9, Lot 55 Septic System Upgrade Design Narrative The owner is preparing the subject property to be put on the market for sale in 2026.  The existing undocumented septic system needs to be upgraded.  The existing septic tank and drainfield will be decommissioned in accordance with the code.  The proposed septic system will be located at the toe of a steep slope outside of the 100‐foot well radius. The proposed 5‐bedroom septic system upgrade is detailed on the design drawings. If constructed as designed, it will; Satisfy all code required separation distances, Not cause any probable adverse impacts to adjacent properties, Not negatively impact existing wells and septic systems on adjacent properties, Not be adversely affected by potential drainage that could flow onto and off of the subject property. Please feel free to contact me for more discussion. Thanks James “Jay” Crewdson, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261035, Isatou Njie, 04/13/26 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261035, Isatou Njie, 04/13/26 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261035, Isatou Njie, 04/13/26 COSA Checklist_May2025.docx COSA Checklist Legal Description: Parcel ID: If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank Date of pumping Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. DISPOSAL FIELD DATA Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Adequacy test date Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) in Effective depth used in Effective depth remaining in Comments/Deficiencies: T15N, R1W, S9, Lot 55 051-103-28 5+ 6-6-1960 164 0 164 0.954 Crewdson Engineering Casing height (above ground) 24+ in. Date of flow test for COSA 6-1-2026 Static water level at beginning of test 55*4-24-2026 Static water level fluctuated between 55' and 60' during flow test, returned to 55' in 15-seconds. * * *New septic system 6-8-2026 3.3 2.8 * *not required 6 0 6 *new septic system * COSA Checklist_May2025.docx E. SEPARATION DISTANCES From Well on Lot to: (Please enter distances if less than required) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Disposal Field on Lot > 100’ Yes if No ft Neighboring Disposal Fields > 100’ Yes if No ft Sewer Line/Main > 100’ Yes if No ft Sewer Manhole/Cleanout > 100’ Yes if No ft Sewer Service/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required) Tank to Foundation > 10’ Yes if No ft Field to Foundation > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main/Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Phone Engineer’s Printed Name Date ✔✔ ✔✔ ✔✔ ✔ ✔ ✔✔ ✔✔ ✔ ✔✔ ✔✔ ✔ Crewdson Engineering, LLC (907) 280-9493 James Crewdson 6-29-2026 Received Date/Time 04/24/2026 10:05 04/24/2026 9:30Collected Date/Time 1261485001 Matrix SGS Ref.# Client Sample ID Hose Bib Client Name Project Name/# Printed Date/Time 05/04/2026 16:53Crewdson Engineering LLC Technical Director Stephen C. Ede 22728 Friendship Lane Drinking Water Sample Remarks: Parameter Results LOQ Units Method Allowable Limits Prep Date Analysis Date InitContainer ID Metals by ICP/MS HBL04/30/26EP200.8ug/LArsenic 04/29/26ND5.00 (<10)B Waters Department DAT05/01/26SM21 4500NO3-Fmg/LTotal Nitrate/Nitrite-N 0.954 0.200 (<10) C Microbiology Laboratory M.A04/24/26SM21 9223B100mLE. Coli Negative 1 A M.A04/24/26SM21 9223B100mLTotal Coliform Negative 1 A 2 of 5