Loading...
HomeMy WebLinkAboutHIGH HOPES LT 2HIGH HOPES Lot 2 15-082- 13 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP261048 Work Type: WellSeptic Initial Tax Code Number: 01508213000 Site Legal Address: HIGH HOPES LT 2 G:2439 Site Mailing Address: 6840 E 99th AVE, Anchorage Owner: RILEY WILLIAM G & SAMANTHA R Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft Total Bedrooms: 5441 { epartinent 4/20/2026 4/20/2027 65923 Non -Public Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Water Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On -Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 5 Special Provisions: A test hole is required prior to construction of the absorption field, in the location shown on the site plan, to confirm minimum separation to impermeable soil and seasonal high groundwater, as well as percolation rate. Construction may proceed at your own risk prior to 7-day groundwater monitoring. If results require a design change, construction shall stop pending approval of a change order. Please submit results with the inspection report (or change order, if required). Issued To: FORGE ENGINEERING Issued By: Curtis Townsend Date: 4/20/2026 Date: 4/20/2026 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 015-082-13 Property owner(s) William & Samantha Riley Day phone (907) 738-2861 Mailing address 13040 Forster Rd, Anchorage, AK 99516 Site address NHN E 99th Ave, Anchorage Legal description High Hopes, Lot 2 Number of Bedrooms 5 Engineering Firm Forge Engineering Building Permit Number Z2 (' ( z L - Not Applicable ❑ APPLICATION IS FOR: APPLICATION IS AN: (® all that apply) Disposal Field ❑ Initial 0 Septic Tank El Upgrade ❑ Holding Tank ❑ Renewal ❑ Privy ❑ Well 0 Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: Permit/Rush Fees: 2O , C'10 Waiver Fees: Date of Payment: `C c'�O lolo 26 Date of Payment: Permit No. ��� �� G C � 4 Waiver No. May 2025 April 16, 2026 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: High Hopes, Lot 2 – NHN E 99th Ave Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 3-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. The proposed system is sized for 5-bedrooms upon owners request. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes from the south west down to the north east steeply, but in the north east corner the slopes are much milder. It is in that flatter area that the new septic system is located. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261048, Curtis Townsend, 04/20/26 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=50' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND HIGH HOPES, LOT 2 FEET 0 50 100 SEPTIC PLAN 4/16/26 10' UTILITY ESMT 10' UTILITY ESMT 565 570 575 580 585 590 595 600 605 610 615 620 625 630 635 640 645645 TH#1 2CO MT FCO CO MT CO 3-BDRM HOME EXISTING WELL PROPOSED WELL 1500-GAL SEPTIC TANK 45' LONG X 3' WIDE, 7' EFFECTIVE DEPTH TRENCH WELL >100' OUTSIDE VIEWPORT 99TH AVE ALTERNATE SITE 25' LONG X 5' WIDE, 0.5' EFFECTIVE DEPTH CONFIRMATION TH TO BE DUG AT TIME OF INSTALL Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261048, Curtis Townsend, 04/20/26 HIGH HOPES, LOT 2 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 3' 6" 3' 7' DESIGN FACTORS:SYSTEM REQUIREMENTS: 750 GPD PEAK FLOW (CUSTOMER REQUEST) PERK RATE: 2.1 MIN/IN APPLICATION RATE: 1.2 GPD/SF 7' DEEP TRENCH SYSTEM 1500-GAL SEPTIC TANK BOTTOM OF TRENCH: 10.5' BELOW GRADE (11.0' MAX) FLOW LINE ELEVATION: 3.5' BELOW GRADE 750 GPD / 1.2 GPD/SF / 7.0' DEEP / 2 SIDES = 44.6 LF TRENCH REQUIRED (45.0 LF SPECIFIED) GEOTEXTILE FABRIC 6" 4/16/26 PROVIDE ADDITIONAL FILL TO ACCOUNT FOR SETTLEMENT Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261048, Curtis Townsend, 04/20/26 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING DEPTH TO WATER AFTER MONITORING 2.1 4/6/26 1 2 3 4 5 6GM (SILTY SAND w/ GRAVEL) Professional Engineers Stamp: HIGH HOPES, LOT 2 4/6/26 015-082-13 WILLIAM RILEY 3 0 16 OB 2:20 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: JUSTIN EARLS 9 0 16 NONE 4/13/26 COMMENTS: SITE PLAN 6 0 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED EXCEPT WHERE NOTED. 4/16/26 MOISTURE NOTED AT TIME OF DIGGING?NO 10:00 3 0 16 8 8 16 5 8 16 10:00 3 0 16 8 0 16 5 0 16 10:00 3 0 16 7 14 16 4 14 16 10:00 3 0 16 7 14 16 4 14 16 10:00 3 0 16 7 14 16 4 14 16 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261048, Curtis Townsend, 04/20/26