HomeMy WebLinkAboutHIGH HOPES LT 2HIGH HOPES
Lot 2
15-082- 13
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
hftp://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP261048
Work Type: WellSeptic Initial
Tax Code Number: 01508213000
Site Legal Address: HIGH HOPES LT 2 G:2439
Site Mailing Address: 6840 E 99th AVE, Anchorage
Owner: RILEY WILLIAM G & SAMANTHA R
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Effective Date:
Expiration Date:
Lot Size in Sq Ft
Total Bedrooms:
5441 {
epartinent
4/20/2026
4/20/2027
65923
Non -Public
Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Water Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Coodinate with On -Site staff regarding preferred method.
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
5
Special Provisions: A test hole is required prior to construction of the absorption field, in the location shown on
the site plan, to confirm minimum separation to impermeable soil and seasonal high groundwater, as well as
percolation rate. Construction may proceed at your own risk prior to 7-day groundwater monitoring. If results
require a design change, construction shall stop pending approval of a change order. Please submit results with
the inspection report (or change order, if required).
Issued To: FORGE ENGINEERING
Issued By: Curtis Townsend
Date: 4/20/2026
Date: 4/20/2026
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section
ON -SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 015-082-13
Property owner(s) William & Samantha Riley Day phone (907) 738-2861
Mailing address 13040 Forster Rd, Anchorage, AK 99516
Site address NHN E 99th Ave, Anchorage
Legal description High Hopes, Lot 2
Number of Bedrooms 5
Engineering Firm Forge Engineering
Building Permit Number Z2 (' ( z L - Not Applicable ❑
APPLICATION IS FOR: APPLICATION IS AN:
(® all that apply)
Disposal Field
❑ Initial 0
Septic Tank
El Upgrade ❑
Holding Tank
❑ Renewal ❑
Privy
❑
Well
0
Water Storage
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
Permit/Rush Fees: 2O , C'10 Waiver Fees:
Date of Payment: `C c'�O lolo 26 Date of Payment:
Permit No. ��� �� G
C � 4 Waiver No.
May 2025
April 16, 2026
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: High Hopes, Lot 2 – NHN E 99th Ave
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot intends to build a 3-bedroom home on the property, so we are
submitting this permit application for the construction of a new well and septic system. The
attached site plan identifies the location of the home as well as the proposed well, septic location
and alternate site. The proposed system is sized for 5-bedrooms upon owners request. No conflicts
exist between this proposed system and any other well or septic system, whether on this lot or
adjacent lots.
The ground surface on the lot slopes from the south west down to the north east steeply, but in the
north east corner the slopes are much milder. It is in that flatter area that the new septic system is
located. There are no slopes greater than 25% within 50 feet downslope of either the primary or
alternate site. Contours are shown on the site plan showing the grade and direction of flow.
Stormwater drainage will not impact this septic system. The new trench will be constructed parallel
to the slope as much as possible.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all
wells and surface water, and more than 5’ away from the septic tank. The alternate site is located
more than 6’ away. Please refer to the attached test hole log, plan and profile pages for the septic
design. If this design is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP261048, Curtis Townsend, 04/20/26
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
1"=50'
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
HIGH HOPES, LOT 2
FEET
0 50 100
SEPTIC PLAN
4/16/26
10' UTILITY ESMT
10' UTILITY ESMT
565
570
575
580
585
590
595
600
605
610
615
620
625
630
635
640
645645
TH#1
2CO
MT
FCO
CO
MT
CO
3-BDRM HOME
EXISTING WELL
PROPOSED WELL
1500-GAL
SEPTIC TANK
45' LONG X 3' WIDE, 7'
EFFECTIVE DEPTH TRENCH
WELL >100' OUTSIDE
VIEWPORT
99TH AVE
ALTERNATE SITE 25' LONG
X 5' WIDE, 0.5' EFFECTIVE
DEPTH
CONFIRMATION TH TO BE
DUG AT TIME OF INSTALL
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP261048, Curtis Townsend, 04/20/26
HIGH HOPES, LOT 2
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
4" PERFORATED PVC (HOLES DOWN)
DRAINFIELD ROCK
3'
6"
3'
7'
DESIGN FACTORS:SYSTEM REQUIREMENTS:
750 GPD PEAK FLOW (CUSTOMER REQUEST)
PERK RATE: 2.1 MIN/IN
APPLICATION RATE: 1.2 GPD/SF
7' DEEP TRENCH SYSTEM
1500-GAL SEPTIC TANK
BOTTOM OF TRENCH: 10.5' BELOW GRADE (11.0' MAX)
FLOW LINE ELEVATION: 3.5' BELOW GRADE
750 GPD / 1.2 GPD/SF / 7.0' DEEP / 2 SIDES = 44.6 LF TRENCH REQUIRED
(45.0 LF SPECIFIED)
GEOTEXTILE FABRIC
6"
4/16/26
PROVIDE ADDITIONAL FILL TO
ACCOUNT FOR SETTLEMENT
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP261048, Curtis Townsend, 04/20/26
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
DEPTH
(feet)
TEST HOLE 1
DATE READING NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERCOLATION RATE: (MIN/INCH)
(inches)(inches)
DATE OF MONITORING
DEPTH TO WATER AFTER MONITORING
2.1
4/6/26 1
2
3
4
5
6GM (SILTY SAND w/ GRAVEL)
Professional Engineers Stamp:
HIGH HOPES, LOT 2
4/6/26 015-082-13
WILLIAM RILEY
3 0
16
OB
2:20
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
PERC TEST LOCATION
TECHNICIAN: JUSTIN EARLS
9 0
16
NONE
4/13/26
COMMENTS:
SITE PLAN
6 0
16
USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED EXCEPT WHERE NOTED.
4/16/26
MOISTURE NOTED AT TIME OF DIGGING?NO
10:00 3 0
16 8 8
16 5 8
16
10:00 3 0
16 8 0
16 5 0
16
10:00 3 0
16 7 14
16 4 14
16
10:00 3 0
16 7 14
16 4 14
16
10:00 3 0
16 7 14
16 4 14
16
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP261048, Curtis Townsend, 04/20/26