Loading...
HomeMy WebLinkAboutOVERLOOK ESTATES #3 LT 4Onsite File OVERLOOK ESTATES #3 LOT 4 PID# 067-231-17 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP261067 Work Type: WellSeptic Initial Tax Code Number: 06723117000 Site Legal Address: OVERLOOK ESTATES #3 LT 4 G: Site Mailing Address: 27792 WILDE CIR, Eagle River Owner: WM CONSTRUCTION LLC Design Engineer: FORGE ENGINEERING This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date Lot Size in Sq Ft: Total Bedrooms: ,»>enfi f;. LC:'1181'CPTlI'".nr 4/30/2026 4/30/2027 61626 Non -Public Q Water Well ❑ Water Storage All construction shall be in accordance with - 1 . ith:1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On -Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing TILSpecial Provisions: The Engineer is required to do an additional percolation test prior to construction of the septic field. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval Issued To: FORGE ENGINEERING Issued By: Isatou B Njie Date: 4/30/2026 Date: 4/30/2026 4 MUNICIPALITY OF Development Services Department F On -Site Water & Wastewater Section ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 067-231-1700 Property owner(s) WM construction LLC Mailing address Po Box 4042, Palmer, AK 99645 Site address NHN Wilde Circle Legal description Overlook Estates Phase 3 Lot 4 Number of Bedrooms 4 Engineering Firm Forge Engineering Day phone 907-707-6326 Building Permit Number Not Applicable F-1 APPLICATION IS FOR: APPLICATION IS AN: (Z all that apply) Absorption Field Initial Septic Tank El Upgrade ❑ Holding Tank M Renewal El Privy 0 Well 0 THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: , — I Permit/Rush Fees: I § -j Waiver Fees: Date of Payment: -(I 5P Permit No. ()SPL C Date of Payment: Waiver No. Distance: M Adpadity of An&"age On-site Water and Wastewater f: aTifaTiS�TY*_* 'S.0. K*,,I'i =.;h OSP261067, Isatou the, 04/XM April 29, 2026 M 522-7773 677_7766 (FAX) MOA Development Services, On -Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Overlook Estates #3 lot 4 — NHN Wilde Circle Septic system design Dear On -Site Services Engineer: The owner of the above lot intends to build a 4 -bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes toward the back of the lot slightly. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. We designed this system according to adjacent properties and available test hole information. A confirmation test hole is required prior to installation Wells on this and adjacent lots are shown. The new system will be a minimum of 100' from all wells and surface water, and more than 5' away from the septic tank. The alternate site is located more than 8' away. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin S' hiller, PE a a. ui F- 0 ui mo Z, ui Lmu F- U) o -ujj Z (.) :D UJ F - L<11 Z JOS (D F - z LO z z w P U) > 0 Z --1a25 0 0M z -1 a 25 0 w x w m < D X: LU 0 0Z a. u) 0 < 0 0 z z -j Uj Lij LL U) F- U) LU (D ui 800 0 0 0 F- > x U- LL 0 F - W w U) 0 a w 0 Z U) X W X LLJ U) 0 U) 0 Z W LU LL - a. ui mo LO LU w U) 0 0 (L 0 U) w w 1— -j 0 uj w 0 0 LL w F- a. Z m U) LU 0 z w 0 z < W 2 z �21 0- 0 w= Z w 0 U- z0 F- 0 < 00 W U- w w P: w wU- Z 0 u) <w ui a. Of q) w Z �- W - V - F - 0 Z U) in < o Ui In C14 x (D F- P CL Z CL m 0 0w E w z m 0 w 0 Z U) X W X LLJ U) 0 U) 0 Z W LU LL - Or�-site Water and Waste��er OVERLOOK ESTATES #3, LOT 4 MMBMD FOR CaX COWUA OSP261067, Isatou /lie, 00" DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW 5.0' WIDE TRENCH SYSTEM PERK RATE: 1.7 MIN/IN 1250 -GAL SEPTIC TANK APPLICATION RATE: 1.2 GPD/SF 600 GPD / 1.2 GPD/SF / 5.0' WIDE * 0.5 RED FACTOR [4.0' DEEP] = 50.0 LF TRENCH REQUIRED (50.0 LF SPECIFIED) BOTTOM OF TRENCH: 7.5' BELOW GRADE FLOW LINE ELEVATION: 3.5' BELOW GRADE PROVIDE ADDITIONAL FILL TO ACCOUNT FOR SETTLEMENT TEXTILE FABRIC :RFORATED PVC (HOLES DOWN) NFIELD ROCK TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE TOF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY .......... .......... Benja • * Schiller CE 12592 3/30/26.