Loading...
HomeMy WebLinkAboutANCHOR VIEW #1 LT 2Onsite File ANCHOR VIEW#1 LOT 2 PID# 015-461-41 Permit Number:OSP261031 Tax Code Number:01546141000 Work Type:WellSeptic Initial Effective Date: Design Engineer: Site Legal Address:ANCHOR VIEW #1 LT 2 G:2741 Owner:KULIN ROBB Site Mailing Address: Lot Size in Sq Ft:217868 Total Bedrooms:5 This permit is for the construction of: Disposal Field Septic Tank Holding Tank Privy Non-Public Water Well Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On-Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 5/5/2026 5/5/2027 FORGE ENGINEERING Expiration Date: þ þ ¨¨þ ¨ Issued To: Issued By: Date: Date: 5/5/2026 5/5/2026 FORGE ENGINEERING Isatou B Njie MUNICIPALITY OF ANCHORAGE On-Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On-Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE k -Affl, Development Services Department 907-343-7904 Phone. On -Site Water & Wastewater Section ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 015-461-41 Property owner(s) Robb Kulin Day phone _ Mailing address 10841 Glazanof Dr, Anchorage, AK 99507 Site address NHN Sultana Dr, Anchorage, AK Legal description Anchor View #1, Lot 2' Number of Bedrooms 5 Engineering Firm Forge Engineering Building Permit Number Not Applicable [] APPLICATION IS FOR: APPLICATION IS AN: E all that apply) Disposal Field F] Initial Septic Tank F] Upgrade ❑ Holding Tank n Renewal El Privy EJ Well Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Permit/Rush Fees: Date of Payment: C i0 Permit No. May 2025 Waiver Fees: Date of Payment: Waiver No. Distance: February 27, 2026 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Anchor View #1, Lot 2 – NHN Sultana Dr Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot has slopes ranging from 15%-25% from the south west down to the north east across most of the lot. The section immediately after the proposed system has a milder slope of around 10% for about 100 feet. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261031, Isatou Njie, 05/05/26 CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FD - FLOW DIVERTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND 1"=50' ANCHOR VIEW #1, LOT 2 FEET 0 50 100Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 2/26/26 SEPTIC PLAN PROPOSED 4-BDRM HOME 4 NEW 50' LONG X 5' WIDE, 0.5 ED TRENCHES PROPOSED WELL TH#1 MTCO MT CO MT CO CO CO CO CO CO MT MT MT MT MT 2CO FD FD NEW 2500-GAL SEPTIC TANK EXISITING WELL 100' RADIUS PROPOSED SYSTEM >100' FROM SOUTH LOT LINE PROPOSED SYSTEM >100' FROM EAST LOT LINE 1450 14451440 1435 1430 14251420 1415 1410 1405 1400 1395 1390 1385 1380 NEIGHBORING SEPTIC >100' FROM VIEWPORT FCO FD ALTERNATE SITE CAT III, 30' LONG, 5' WIDE, 0.5' EFFECTIVE DEPTH Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261031, Isatou Njie, 05/05/26 ANCHOR VIEW #1, LOT 2 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER DESIGN FACTORS:SYSTEM REQUIREMENTS: 750 GPD PEAK FLOW (CLIENT REQUEST) PERK RATE: 6.7 MIN/IN APPLICATION RATE: 0.8 GPD/SF 5' WIDE TRENCH SYSTEM 2500-GAL SEPTIC TANK (CLIENT REQUEST) BOTTOM OF TRENCH: 3.5' BELOW GRADE MAX FLOW LINE ELEVATION: 3.0' BELOW GRADE 750 GPD / 0.8 GPD/SF / 5' WIDE * 1.0 RED FACTOR [0.5 DEEP] = 187.5 LF TRENCH REQUIRED (200.0 LF SPECIFIED) 2/26/26 6" 6" 3' Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261031, Isatou Njie, 05/05/26 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING DEPTH TO WATER AFTER MONITORING 6.7 2/5/26 1 2 3 4 5 6GM (SILTY SANDY GRAVEL) Professional Engineers Stamp: ANCHOR VIEW #1 LOT 2 2/5/26 015-461-41 SETH ANDERSEN 8 OB 30 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: JARED E 2 8 16 9.5' 2/17/26 COMMENTS: SITE PLAN 5 8 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED EXCEPT WHERE NOTED. 2/25/26 MOISTURE NOTED AT TIME OF DIGGING?NONE 830 3 5 16 4 7 16 830 3 5 16 4 7 16 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261031, Isatou Njie, 05/05/26