HomeMy WebLinkAboutLAKE HILL ACRES #6 BLK B LT 3LAKE HILL ACRES #6
Lot 3
#051- 122-44
MUNICIPALITY OF ANCHORAGE
On -Site Water $ Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
hftp://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP261071
Work Type: WellSeptic Initial
Tax Code Number: 05112244000
Site Legal Address: LAKE HILL ACRES #6 BLK B LT 3 G:1562
Site Mailing Address: 22140 ANTHEM PL, Chugiak
Owner: HALL ROBERT HENRY 50%
Design Engineer: NORTH RIM ENGINEERING
This permit is for the construction of:
Effective Date
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
5/6/2026
5/6/2027
LM:3:Z:3
Non -Public
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy LQ Water Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Coodinate with On -Site staff regarding preferred method.
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Issued To: NORTH RIM ENGINEERING
Date:
5/6/2026
Issued By: Curtis Townsend Date: 5/6/2026
4
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section
ON -SITE SEPTICIWELL PERMIT APPLICATION
Parcel I.D. 05112244000
Property owner(s) HALL JESSIE HAROLD JR Day phone 350-5068
Mailing address PO BOX 770336 EAGLE RIVER, AK 99577
Site address Anthem
Legal description
LAKE HILL ACRES #6 BLK B LT 3
Number of Bedrooms 4
Engineering Firm NorthRim Eng.
Building Permit Number , Not Applicable ❑■
APPLICATION IS FOR:
APPLICATION IS AN:
(® all that apply)
Absorption Field
0 Initial 0
Septic Tank
❑ Upgrade ❑
Holding Tank
❑ Renewal ❑
Privy
❑
Well
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Permit/Rush Fees: 2'C" c
Date of Payment:
Permit No.
Waiver Fees:
Date of Payment:
Waiver No.
Distance:
AN
T
H
E
M
P
L
A
C
E
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP261071, Curtis Townsend, 05/06/26
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP261071, Curtis Townsend, 05/06/26
SteveEng.com Lake Hill Acres #6 Block B L3
SPECIFICATIONS & DESIGN GUIDELINES
Wastewater System Sizing: This is a newly developing lot, planned for a 4-bedroom,
single family home. A design is submitted for a new trench & new Category III Advantex
w/Lift Station. The neighboring lots are large; this upgrade will not impact neighbor lots.
Groundwater was recently monitored @ 7 depth. A 5 - wide trench will be built up from
the surface, mound style. A new water well is planned at the site indicated. A Category
III application rate of 6 GPD/FT². Trench Length = 100 FT²/5 = 20 . No bedrock was
encountered, but silt requires a raised field. Advanced system allows 2 separation to
groundwater and 4 to silt soil.
Specification Requirements: All components and work must comply with the
Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water
Regulations and Wastewater Regulations.
Connect New Raised Trench To Advantex/Lift Station, steel, anti-floatation.
Watertight couplings, inlet & outlet. 1500 gallons w/ 1 AX-20 pod.
5 minimum between the tank and trench. 10 to property lines.
3 of cover is required for trench or add insulation board.
Solid pipe must be set on well compacted, stable soil
4 of cover or insulation is required for tank; an equivalent of 1 insulation for 1 foot
soil cover. Tank & solid pipe must be set on well compacted, stable soil.
4 diameter cleanouts with airtight caps are required 1 to 4 from foundation wall,
prior to any 90 degree bend in 4 inch line, in each tank compartment, and two
adjacent opposing cleanouts between the tank and the absorption field, not more than
10 from the tank positioned to provide cleanout access towards the tank and towards
the absorption field.
All cleanouts must extend to at least ground level.
In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron.
Trench to be placed level, minimum of 2 to groundwater, 4 to silt.
Drain rock to be ½ inch to 2 inch screened. Drain rock to be distributed uniformly.
Force main to be 1.25 Schedule 40 PVC or equal.
Distribution pipe to be 1.25 Schedule 40 PVC w/ 1/8 orifice @ 18 on-center.
Silt barrier (filter fabric) to be installed above the drain rock
Smeared trench sides must be raked or scarified before drain rock placement
Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789,
ABS ASTM D2661, PVC Schedule 40.
Sewer Service Line is minimum 2% slope
Septic Tank to be pumped every two years or when required
Insulation board shall be extruded direct burial polystyrene (Dow Styrofm HI/equal)
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP261071, Curtis Townsend, 05/06/26
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP261071, Curtis Townsend, 05/06/26
MUNICIPALITY OF ANCHORAGE
ADVANCED WASTEWATER TREATMENT SYSTEM
MAINTENANCE AND REPAIR AGREEMENT
THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and
entered into as of this 6 Day of of 20 , by and between
herein the "OWNER," and the Municipality of
Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code
(AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this
Agreement agree as follows:
1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the
Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS),
described as ADVANTEX
located at (legal description)
Lake Hill Acres *6 Block B Lot 3
2. Maintenance, Repairs and Alterations.
(Owner is required to read, understand and initial each section)
Throughout the term of this Agreement, the Owner shall enter into a service agreement
with an AWWTS service and maintenance provider approved by the Municipality or the
manufacturer's representative. The AWWTS shall be maintained in a satisfactory
condition capable of performing as designed and producing treated septic effluent in
accordance with the equipment's approval for operation in the Municipality.
It shall be the responsibility of the Owner during the term of this Agreement to pay for all
repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This
includes an annual maintenance fee (typically $400 to $600).
Owner agrees that only maintenance and repair personnel approved by the Municipality
or the manufacturer's representative will inspect and make any necessary maintenance,
repairs or permitted alterations to the system.
Owner acknowledges that regular maintenance of an AWWTS reduces the potential
failure of the system, which could include sewage backup and costly repairs or drainfield
replacement.
(rev. 05/18/2018) Page 1 of 3
Owner acknowledges that the Municipality may request records of maintenance and
repairs from the manufacturer's representative or maintenance provider.
Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be
assessed in accordance with AMC 14.60.030.
Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS. The Municipality will give at least 24-hour notice.
Owner agrees that any sale or transfer of title of the property will not occur without a new
Certificate of On -Site Systems Approval.
Owner agrees that the AWWTS installation and maintenance requirements as provided
by the AWWTS vendor/installer and approved by the Municipality are the governing
guidelines for the construction, maintenance and repair of the Owner's AWWTS.
Owner agrees to maintain remote monitoring of the AWWTS as required by the
AWWTS approval.
3. Term. The term of this Agreement shall begin on the date of approval by the
Municipality to operate the installed system, or upon transfer of title, and shall continue
while the AWWTS is operational or until title is transferred.
4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this
Agreement shall in no way constitute a waiver of the provisions, nor in any way affect
the validity of the Agreement or any part hereof, or the right of the Municipality
thereafter to enforce every provision hereof.
5. Amendment. This Agreement shall only be amended by authorized representatives of
the Owner and Municipality. Any attempt to amend this agreement by either an
unauthorized representative or unauthorized means shall be void.
6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be
brought in the Superior Court for the Third Judicial District of the State of Alaska at
Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the
parties under this Agreement.
7. Severability. Any provisions of this Agreement decreed invalid by a court of competent
jurisdiction shall not invalidate the remaining provisions of the Agreement.
(rev. 05/18/2018) Page 2 of 3
OWNER:
By: (signature) Date:
—(print name)
STATE OF ALASKA
) ss.
THIRD JUDICIAL DISTRICT
The foregoing instrume t was acknowledged before me this $' day of lrja'�
20 by 6ssfe IL
NOTARY PUBLIC FOR ALASKA
My Commission expires: 0 - — 26 — ZCS-j c)
MUNICIPALITY: Alckn ray e-
By: _(signature) Date: -6/6 /Z-0 2�g
—(print name) Title:
Y
Official seal
state of Alaska
Notary Public
A. Watson
Commis
W20013 Comrnssi'l,
MEofficigil si-&—1
State of Alaska t JA/3
Notary Pubft
A. VVaftw
G M20013 Cn-misr�mOOM
03re2030 S 1
'70-26
(rev. 05/18/2018) Page 3 of 3