Loading...
HomeMy WebLinkAboutLAKE HILL ACRES #6 BLK B LT 3LAKE HILL ACRES #6 Lot 3 #051- 122-44 MUNICIPALITY OF ANCHORAGE On -Site Water $ Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP261071 Work Type: WellSeptic Initial Tax Code Number: 05112244000 Site Legal Address: LAKE HILL ACRES #6 BLK B LT 3 G:1562 Site Mailing Address: 22140 ANTHEM PL, Chugiak Owner: HALL ROBERT HENRY 50% Design Engineer: NORTH RIM ENGINEERING This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 5/6/2026 5/6/2027 LM:3:Z:3 Non -Public Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy LQ Water Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On -Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Issued To: NORTH RIM ENGINEERING Date: 5/6/2026 Issued By: Curtis Townsend Date: 5/6/2026 4 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section ON -SITE SEPTICIWELL PERMIT APPLICATION Parcel I.D. 05112244000 Property owner(s) HALL JESSIE HAROLD JR Day phone 350-5068 Mailing address PO BOX 770336 EAGLE RIVER, AK 99577 Site address Anthem Legal description LAKE HILL ACRES #6 BLK B LT 3 Number of Bedrooms 4 Engineering Firm NorthRim Eng. Building Permit Number , Not Applicable ❑■ APPLICATION IS FOR: APPLICATION IS AN: (® all that apply) Absorption Field 0 Initial 0 Septic Tank ❑ Upgrade ❑ Holding Tank ❑ Renewal ❑ Privy ❑ Well THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Permit/Rush Fees: 2'C" c Date of Payment: Permit No. Waiver Fees: Date of Payment: Waiver No. Distance: AN T H E M P L A C E Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261071, Curtis Townsend, 05/06/26 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261071, Curtis Townsend, 05/06/26 SteveEng.com Lake Hill Acres #6 Block B L3 SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: This is a newly developing lot, planned for a 4-bedroom, single family home. A design is submitted for a new trench & new Category III Advantex w/Lift Station. The neighboring lots are large; this upgrade will not impact neighbor lots. Groundwater was recently monitored @ 7 depth. A 5 - wide trench will be built up from the surface, mound style. A new water well is planned at the site indicated. A Category III application rate of 6 GPD/FT². Trench Length = 100 FT²/5 = 20 . No bedrock was encountered, but silt requires a raised field. Advanced system allows 2 separation to groundwater and 4 to silt soil. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. Connect New Raised Trench To Advantex/Lift Station, steel, anti-floatation. Watertight couplings, inlet & outlet. 1500 gallons w/ 1 AX-20 pod. 5 minimum between the tank and trench. 10 to property lines. 3 of cover is required for trench or add insulation board. Solid pipe must be set on well compacted, stable soil 4 of cover or insulation is required for tank; an equivalent of 1 insulation for 1 foot soil cover. Tank & solid pipe must be set on well compacted, stable soil. 4 diameter cleanouts with airtight caps are required 1 to 4 from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10 from the tank positioned to provide cleanout access towards the tank and towards the absorption field. All cleanouts must extend to at least ground level. In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. Trench to be placed level, minimum of 2 to groundwater, 4 to silt. Drain rock to be ½ inch to 2 inch screened. Drain rock to be distributed uniformly. Force main to be 1.25 Schedule 40 PVC or equal. Distribution pipe to be 1.25 Schedule 40 PVC w/ 1/8 orifice @ 18 on-center. Silt barrier (filter fabric) to be installed above the drain rock Smeared trench sides must be raked or scarified before drain rock placement Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, PVC Schedule 40. Sewer Service Line is minimum 2% slope Septic Tank to be pumped every two years or when required Insulation board shall be extruded direct burial polystyrene (Dow Styrofm HI/equal) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261071, Curtis Townsend, 05/06/26 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261071, Curtis Townsend, 05/06/26 MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this 6 Day of of 20 , by and between herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as ADVANTEX located at (legal description) Lake Hill Acres *6 Block B Lot 3 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: By: (signature) Date: —(print name) STATE OF ALASKA ) ss. THIRD JUDICIAL DISTRICT The foregoing instrume t was acknowledged before me this $' day of lrja'� 20 by 6ssfe IL NOTARY PUBLIC FOR ALASKA My Commission expires: 0 - — 26 — ZCS-j c) MUNICIPALITY: Alckn ray e- By: _(signature) Date: -6/6 /Z-0 2�g —(print name) Title: Y Official seal state of Alaska Notary Public A. Watson Commis W20013 Comrnssi'l, MEofficigil si-&—1 State of Alaska t JA/3 Notary Pubft A. VVaftw G M20013 Cn-misr�mOOM 03re2030 S 1 '70-26 (rev. 05/18/2018) Page 3 of 3