HomeMy WebLinkAboutOVERLOOK ESTATES #2 LT 9OVERLOOK ESTATES
#2
Lot 9
67- 231 -08
MUNICIPALITY OF ANCHORAGE
On -Site Water& Wastewater Program
POBox 1S005O 47VVElmore Road
Anchorage, Alaska 995\9-805O Phone: ) 904 Fax: (8O7)343'7887
hup:8vww*.muni.org/onoite
On -Site Water & Wastewater System Permit
Permit Number: OSP201114
Work Type: VVeUSeotic|nitia
Tax Code Number: 06723108000
Site Legal Address: OVERLOOK ESTATES #2LT S G:
Site Mailing Address:
Owner: ELEGANT HOMES LLC
Design EngineerFORGE ENGINEERING
This permit is for the construction of:
Effective Date:
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
5/18/2026
5/18/2027
Non -Public
Disposal Field 2 Septic Tank El Holding Tank El Privy 10 Water Well F1 Water Storage
All construction shall beinaccordance with:
1. The attached approved design.
2. All requirements specified inAnchorage Municipal codChapters 1555 and15G5 andth State ofAlaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
-. The wastewater ---- requires inspections during^the installation.^^The engineer^shall notify the ~~`~'~p'''~''^
Services Department per AMC 15.65. Coodinatewith On -Site staff regarding preferred method.
4. From October 1SboApril 15, m subsurface soil absorption system under construction during freezing weather
shall beeither:
e. Opened and Closed onthe same day, nr
b. Covered, sealed, and heated hoprevent freezing
Issued To: FORGE ENGINEERING
Date:
5/18/2026
Issued By: Curtis Townsend 5U8/2028
MUNICIPALITY OF ANCHORAGE
jw
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section
ON -SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 067-231-08
Property owners) Mykola Selyutin Day phone (907) 751-4140
Mailing address 1431 W CATRI NA C I R, WAS I LLA, AK, 99654
Site address NHN Eagle River Road
Legal description Overlook Estates #2, Lot 9
Number of Bedrooms 4
Engineering Firm Forge Engineering
Building Permit Number i (0 Not Applicable ❑■
APPLICATION IS FOR: APPLICATION IS AN:
(® all that apply)
Disposal Field
M Initial 0
Septic Tank
x❑ Upgrade ❑
Holding Tank
❑ Renewal ❑
Privy
❑
Well
x❑
Water Storage
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Permit/Rush Fees: G L. J
Date of Payment:
Permit No. G-S
Waiver Fees:
Date of Payment:
Waiver No.
Distance:
May 2025
May 13, 2026
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Overlook Estates #2, Lot 9 – NHN Eagle River Road
Septic System Design
Dear On-Site Services Engineer:
The owner of the above-referenced lot intends to construct a 4-bedroom home on the property.
We are therefore submitting this permit application for the construction of a new well and septic
system. The attached site plan identifies the proposed home, well, septic system location, and
alternate site. No conflicts exist between this proposed system and any existing well or septic
system on this lot or adjacent lots.
The ground surface on the lot is fairly flat. There are no slopes greater than 25% within 50 feet
downslope of either the primary or alternate site. Existing contours are shown on the site plan
indicating the grade and drainage direction. Stormwater drainage is not expected to impact the
proposed septic system. The absorption trench will be constructed parallel to the slope as much
as practical.
Wells on this and adjacent lots are shown on the site plan. The proposed system will maintain a
minimum 100-foot separation from all wells and surface water. The septic tank will maintain a
minimum 5-foot separation from the absorption system, and the alternate site is located more
than 6 feet away. Please refer to the attached test hole log and plan/profile sheets for additional
septic design information. If constructed as designed, the proposed system is not expected to
adversely impact adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP261114, Curtis Townsend, 05/18/26
ALTERNATE SITE
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
1"=50'
EXISTING SEPTIC
SYSTEM
1250-GAL SEPTIC
TANK
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
2CO
MT
TH#1
OVERLOOK ESTATES #2 LOT 9
FEET
0 50 100
FCO
EAG
L
E
R
I
VER
R
O
A
D
SEPTIC PLAN
5/13/26
CO
10' UTILITY EAS
EME
N
T
(2)60' LONG x 5' WIDE,
0.5' EFFECTIVE
DEPTH
ABSORPTION
TRENCHES w/ 2'
SAND FILTER
MT
CO
MT
CO
MT
CO
FS
4-BDRM HOME
LOT 8 WELL RADIUS
PROPOSED WELL
410
410
420
425
435
440
445
450
455455
415
420
425
430
435
440
445
450
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP261114, Curtis Townsend, 05/18/26
OVERLOOK ESTATES #2 LOT 8
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
4" PERFORATED PVC (HOLES DOWN)
DRAINFIELD ROCK
DESIGN FACTORS:SYSTEM REQUIREMENTS:
600 GPD PEAK FLOW
PERK RATE: <1 MIN/IN
APPLICATION RATE: 1.0 GPD/SF
5' WIDE TRENCH SYSTEM w/ 2.0' SAND FILTER
1250-GAL SEPTIC TANK
BOTTOM OF TRENCH: 4' BELOW GRADE
FLOW LINE ELEVATION: 3.5' BELOW GRADE
600 GPD / 1.0 GPD/SF / 5' WIDE * 1.0 RED FACTOR [0.5' DEEP] = 120 LF TRENCH REQUIRED
(120 LF SPECIFIED)
GEOTEXTILE FABRIC
5/7/26
PROVIDE ADDITIONAL FILL TO
ACCOUNT FOR SETTLEMENT
6"
5'
2'
6"
3'
MOA APPROVED FILTER SAND
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP261114, Curtis Townsend, 05/18/26
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
DEPTH
(feet)
TEST HOLE 1
DATE READING NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERCOLATION RATE: (MIN/INCH)
(inches)(inches)
DATE OF MONITORING
DEPTH TO WATER AFTER MONITORING
0.82
5/7/26 1
2
3
4
5
6GM (SANDY GRAVEL)
Professional Engineers Stamp:
OVERLOOK ESTATES #2, LOT 9
5/7/26 067-231-08
ELEGANT HOMES
2 0
16
0.5' OB
4:55
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
PERC TEST LOCATION
TECHNICIAN: JARED EARLS
8 0
16
NONE
5/14/26
COMMENTS:
SITE PLAN
6 0
16
USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED EXCEPT WHERE NOTED.
5/7/26
MOISTURE NOTED AT TIME OF DIGGING?NO
2 0
165:00 8 0
16 6 0
16
2 8
164:56 8 8
16 6 0
16
2 0
164:56 8 0
16 6 0
16
2 0
164:55 8 0
16 6 0
16
2 0
164:55 8 0
16 6 0
16
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP261114, Curtis Townsend, 05/18/26