Loading...
HomeMy WebLinkAboutSHANGRI-LA ESTATES-EAST PH 2 BLK 5 LT 2SHANGRI-LA ESTATES -EAST PH 2 Lot 2 0 EON @war-jwf%Aft MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP261099 Work Type: WellSeptic Initial Tax Code Number: 02004385000 Effective Date: Expiration Date 5/20/2026 5/20/2027 Site Legal Address: SHANGRI-LA ESTATES -EAST PH 2 BLK 5 LT 2 G:3239 Site Mailing Address: Owner: SELLMAN JEFFREY Lot Size in Sq Ft: 56614 Design Engineer: FIRST WATER CONSULTING Total Bedrooms: This permit is for the construction of: Non -Public Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Water Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On -Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Issued To: FIRST WATER CONSULTING Issued By: Curtis Townsend Date: 5/20/2026 Date: 5/20/2026 3 MUNICIPALITY OF ANCHORAGE Development Services Department / Phone: 907-343-7904 On -Site Water & Wastewater Section ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 020-043-85 Property owner(s) JEFFREY SELLMAN Day phone Mailing address 1200 1 STREET UNIT 702, ANCHORAGE, AK 99501 Site address NHN MOUNTAIN AIR DRIVE, ANCHORAGE Legal description SHANGRI-LA ESTATES PHASE 2, BLOCK 5, LOT 2 Number of Bedrooms 3 Engineering Firm FIRST WATER CONSULTING Building Permit Number FORTHCOMING Not Applicable ❑ APPLICATION IS FOR: APPLICATION IS AN: (® all that apply) Disposal Field 0 Initial Fx_1 Septic Tank Upgrade ❑ Holding Tank ❑ Renewal ❑ Privy ❑ Well 0 Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: Permit/Rush Fees: `5 C_ "D Waiver Fees: Date of Payment: ! �3 ! r c Date of Payment: Permit No. _ C! S Waiver No. May 2025 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / firstwaterAK@gmail.com ! !! May 18, 2026 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: NEW SEPTIC SYSTEM PERMIT LEGAL: SHANGRI-LA ESTATES-EAST PHASE 2, BLOCK 5, LOT 2 The property owner has requested we obtain a new well & septic permit for the above referenced lot. We propose to install shallow trenches and 1500-gallon deep burial HDPE STEP tank to serve the proposed 3-bedroom residence. If shallow groundwater is encountered during installation an epoxy coated steel septic tank, tank anchoring or other action may be required. The design is based on the attached test hole (TH-3) conducted in 2022 by Triad Engineering, LLC located in the MOA record documents that shows groundwater at 8’ on September 2, 2022, and none observed on other dates. Groundwater was recently monitored for TH-3 on May 15, 2026, and was found dry to 10.6’ below grade. Groundwater was also measured in the apparent test hole (TH-4) to the north along the property line of Lots 2 & 3 and was observed at 7’. The property will be served by the proposed well as noted on the design. The slopes are moderate at 8-13% at the proposed upgrade location. The lot and area are served by private water. The design will not impact any of the neighboring properties. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261099, Curtis Townsend, 05/20/26 FIRST WATER CONSULTING DESIGN CALCS: NO WELLS WITHIN 100' OF PROPOSED SEPTIC SYSTEM. NO SLOPES >25% WITHIN 50'OF PROPOSED FIELD. STAKE PROPERTY LINES, WELL RADII, ESMTS, OR OTHER SEPARATIONS... PRIOR TO CONST. SHANGRI-LA ESTATES-EAST PHASE 2, B5, L2 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261099, Curtis Townsend, 05/20/26 FIRST WATER CONSULTING SHANGRI-LA ESTATES-EAST PHASE 2, B5, L2 DESIGN DETAILS: Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261099, Curtis Townsend, 05/20/26 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Section * y�r 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 www.rnuni.cir_q/onsite 343- (907) 343-7904 Soils Log - Percolation Test tslr y'�9 TH P. 11GRANT W. MATHE4Y5 CE 13" : w Performed For: Scott Grigsby Date Performed: 8-17-22 Legal Description: Shangri-La Tract B (Lot 2) Township, Range, Section: TH-3 Depth (Feet) 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- organics, root mat, brown (oy Silty gravel w! sand (GP -GM) Tan.tlense Sandy gravel (GP) Gray, desnse Silty gravel V sand (GP -GM) H igher si It content Gray, dense BOH ® 12' NGWE Site Plan See attached site plan WAS GROUND WATER ENCOUNTERED? No S IF YES, AT WHAT DEPTH? L Depth to Water After a P Monitoring? NGWE E Date: 5-5-23 Reading Date Gross Time Net Time Water Depth Net Drop 10,47am --- --- 6.000" --- 1 10,49am 2 min 2 min 0.000" 6.000" --- --- 6.000" --- 2 10,51am 2 min 4 min 0.0001, 6.000" PERCOLATION RATE jminuteslinch) PERC HOLE DIAMETER TEST RUN BETWEEN 3.5 FT AND 4.5 FT COMMENTS Added approximately 1 gallon of water in less than 1 minute. All water absorbed in less than 2 minutes. Repeated wl same results. PERFORMED BY: Triad Engineering, LLC I Grant Mathews CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 10-21-22