Loading...
HomeMy WebLinkAboutBROADWATER HEIGHTS TR D BLK 1 LT 1Onsite File BROADWATER HEIGHTS TRACT D BLOCK 1 LOT 1 PID# 050-081-42 Permit Number:OSP261186 Tax Code Number:05008142000 Work Type:WellSeptic Initial Effective Date: Design Engineer: Site Legal Address:BROADWATER HEIGHTS TR D BLK 1 LT 1 G:0253 Owner:ARCTIC VALLEY CONSTRUCTION LLC Site Mailing Address: Lot Size in Sq Ft:19801 Total Bedrooms:4 This permit is for the construction of: Disposal Field Septic Tank Holding Tank Privy Non-Public Water Well Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On-Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 7/8/2026 7/8/2027 FORGE ENGINEERING Expiration Date: þ þ ¨¨þ ¨ Issued To: Issued By: Date: Date: 7/8/2026 7/8/2026 FORGE ENGINEERING Isatou B Njie MUNICIPALITY OF ANCHORAGE On-Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On-Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 050-081-42 Properly owner(s) Lindsey & Kyle Grimes Mailing address 19437 Laura Lee Cir, Ea Day phone le River, AK 99577 Site address NHN Broadwater Dr, Eagle River, AK Legal description Broadwater Heights Tract D, Block 1 Lot 1 Number of Bedrooms 4 Engineering Firm Forge Engineering Building Permit Number Not Applicable ❑ APPLICATION IS FOR: APPLICATION IS AN: (® all that apply) Disposal Field ❑x Initial x❑ Septic Tank 0 Upgrade ❑ Holding Tank ❑ Renewal ❑ Privy ❑ Well x❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Permit/Rush Fees: C� S Date of Payment: 2 2 Permit No. May 2025 Waiver Fees: Date of Payment: Waiver No. Distance: June 22, 2026 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Broadwater Heights Tract D, Block 1 Lot 1 – NHN Broadwater Dr Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes anywhere from 30%-40% from east to west across most of the lot. The area where the proposed septic system is located is milder with slopes around 20%. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 50’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261186, Isatou Njie, 07/08/26 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=20' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND BROADWATER HEIGHTS TRACT D, BLOCK 1 LOT 1 FEET 0 20 40 SEPTIC PLAN 6/22/26 20' LONG X 5' WIDE, 0.5' EFFECTIVE DEPTH TRENCH 1500-GAL ADVANTEX FAP SEPTIC TANK MT PV MT FCO 4-BDRM HOME B R O A D W A T E R D R DE V I L S E N D D R NOTE: LOCATE AND CONFIRM PROPOSED WELL IS >50' FROM THE SEPTIC ON THE CLOSEST LOTS TO THE EAST AND WEST. CLOSEST LOTS TO THE NORTH AND SOUTH ARE ALL VACANT PROPOSED WELL w/ 50' RADIUS LOCATE AND CONFIRM WELL IS >50' FROM PROPOSED SEPTIC COMPONENETS. NO ASB IN RECORDS 760 750 740 730 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261186, Isatou Njie, 07/08/26 BROADWATER HEIGHTS TRACT D, BLOCK 1 LOT 1 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER DESIGN FACTORS:SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: <1.0 MIN/IN APPLICATION RATE: 6.0 GPD/SF 5.0' WIDE TRENCH SYSTEM 1500-GAL ADVANTEX FAP SEPTIC TANK BOTTOM OF TRENCH: AT GRADE FLOW LINE ELEVATION: 0.5' ABOVE GRADE 600 GPD / 6.0 GPD/SF / 5' WIDE * 1.0 RED FACTOR [0.5' DEEP] = 20.0 LF TRENCH REQUIRED (20.0 LF SPECIFIED) 6/22/26 2' 6" 2' 6" 11 4" PVC w/ 1 8" ORIFICES EVENLY SPACED @ 1.0' OC MOA APPROVED SAND DRAINFIELD ROCK GEOTEXTILE FABRIC & 2" FOAM INSULATION PROVIDE ADDITIONAL FILL TO ACCOUNT FOR SETTLEMENT 6" MAX 3:1 SLOPE. PROVIDE TOPSOIL & GRASS SEED Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261186, Isatou Njie, 07/08/26 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING DEPTH TO WATER AFTER MONITORING <1.0 6/17/26 1 2 3 4 5 6 GM (SILTY SANDY GRAVEL) Professional Engineers Stamp: BROADWATER HEIGHTS TRACT D, BLOCK 1 LOT 1 6/17/26 050-081-42 LINDSEY & KYLE GRIMES 3 0 16 FILL 0.5 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: JUSTIN EARLS 9 0 16 5.0' 6/24/26 COMMENTS: SITE PLAN 6 0 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED UNLESS OTHERWISE NOTED. 6/29/26 MOISTURE NOTED AT TIME OF DIGGING?YES ORGANICS 3 0 160.5 9 0 16 6 0 16 3 0 160.5 9 0 16 6 0 16 3 0 160.5 9 0 16 6 0 16 3 0 160.5 9 0 16 6 0 16 3 0 160.5 9 0 16 6 0 16 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261186, Isatou Njie, 07/08/26 7/8/2026 Isatou Njie