Municipality of Anchorage
On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP211173 PID Number: 011-133-51
Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New 0 Upgrade
Name
STEVE MCNEESE
ABSORPTION FIELD UPPER/LOVVER
❑ Deep Trench❑ Wide Trench ❑ Bed ❑ Mound
Site Address
5215 WEST 82ND AVE *ANCHORAGE, AK 99502
__jNumber
❑ Other
Phone
of Bedrooms
Soil Rating
Total depth from original grade
907-360-1957
4
1.2 GPD/SF
10 & 10 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
SEE DWG. Ft.
Gravel depth beneath pipe
4 & 4 Ft.
Subdivision Block Lot
SAND LAKE #2; BLOCK 2, LOT 13 & 14
Fill added above original grade
SEE DWG. Ft.
Gravel length
25 & 25 (50) Ft.
Township Range Section
Gravel width
5 & 5 Ft.
Beds: Number of Lines
-
Distance between lines
- Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
500 Ftz
2
8+ Ft.
Well
1001+
100,+
-
-
25'+
TANK ® Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer Capacity
ANCHORAGE TANK 1250 Gal.
Surface Water
100'+
100'+
_
_
Material
Number of compartments
Lot Line
5'+
*51+
_
_
NA
HDPE
2
Foundation
0'+ 1
10'+
_
_
LIFT STATION
Manufacturer
Capacity
Remarks OLD SEPTIC TANK DECOMMISSIONED PER UPC
Gal.
WR#OSV211031
Alarm location
Electrical installed by
Installer
PIPE MATERIAL House to tank D3034Tank to D3034
drainfield
ARM SEPTIC SERVICES
Drainfield D3034 CO/MTD3034
Inspector GEG AND TIM ECKLUND
BENCH MARK (Assumed elevation) 97.58 ft
Inspection 1st 6/22/21 2nd 6/22/21
Location and description
3'd 6/23/21 4th 6/23/21
TOP OF MANHOLE
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
oo6oOp
Conditional Approval: Date5P
o
0O
p.......... ............ ...:. D
0
Septic System
Approved Date /2 ho -If
Jeff r Garn s.
Q 1. p
CE— �Q
,coo
Note: this approval does not include well permit requirements.
nnecc884°OOoo���o
���cv v.n vu iui
Carroll, Rebecca M.
From:
David Garness <David@garnessengineering.com>
Sent:
Thursday, December 9, 2021 8:25 AM
To:
Carroll, Rebecca M.
Subject:
Sand Lake #2; Block 2, Lot 13 & 14
Attachments:
doc11370120211209082429.pdf
Follow Up Flag: Follow up
Flag Status: Flagged
[EXTERNAL EMAIL]
Rebecca,
The "old system" was decommissioned, and a dirt plug was installed between both trenches. I would like to note that Tim
was also onsite during the installation. Also, attached is the updated survey with the MH riser
Sincerely,
David Garness, P.E., M.S.
Civil Engineer
Garness Engineering Group, Ltd.
3701 E. Tudor Road, Suite 101
Anchorage, Alaska 99507
Phone: (907) 337-6179
Mobile: (907) 632-4528
Website: www.garnessengineering.com
� R
GARNESS ENGINEERING GROUP, Ltd
ENGINEERING= SALES, CONSULTING
0ni Cs
r
WRI ORATION
Ata, , i A,nho; i:ed
A:al'o r" +1.'s'14t,; (?ziSHWO
PERMIT NUMBER:
OSP211173
I A I B7
FCO
2.4
18.4
MHl
13.4
21.2
STI
18.2
24.5
DBL1
20.1
25.9
DBL2
21.0
26.6
FS
24.1
29.6
C01
25.7
35.5
MTI
27.1
36.4
CO2
45.3
58.3
MT2
44.4
57.9
CO3
38.3
42.8
MT3
36.4
41.8
C04
52.1
62. 0
MT4
52.2
61fl
NEW DRAINFI
RECORD DRAWING PARCEL ID NUMBER:
011-133-51
WELL RADAII AND LOT LINE
FLAGGED BY A PLS PRIOR TO
jool WELL RADIUS CONSTRUCTION
BLOCK 2, LOT 15
Fz� I
0
DBL1&2
TI ti
o,
S .4 .
�A
S
1 ui
j 0 S 1
/ 1 0 EL
MHl
NIlW 1250 GALLON CO
HOPE GREER TANK A
I x
PREENHOUSE EXISTING 4 0
BEDROOM HOUSE U
F
m
m
>
U)
CARPORT
m
2 1
m
A-
82ND AVENUE
z
A
N
SCALE:
1"=30'
-- ENGINEERING ,,o SALES- CONSULTING
3701 E. TUDOR ROAD, SUITE 101 -ANCHORAGE, ALASKA -PHONE (907)337-6179*WEBSITE: www.gamesser4needng.com
PREPARED FOR: J
PHONE NUMBER:
PAGE NUMBER:
STEVE MCNEESE
907-360-1957
2 OF 3
PROJECTILEGAL DESCRIPTION:
DRAWN BY:
SAND LAKE #2; BLOCK 2, LOT 13 & 14
D.J.G.
TYPE OF WORK:
DATE:
RECORD DRAWINGS OF TANK AND DRAINFIELD
7/6/2021
-OF
0-w ...........
o �'_k i ey A-Zarfiess
% CE -7953
0 ..........
Ix1l
4 PROF
LICENS killkwilk"**
PERMIT NUMBER: PARCEL ID NUMBER:
OSP211173 RECORD DRAWING 011-133-51
1-7,F MH =97.58FINAL GRADE = 96.8-97.3
MHrT-2�
I I
2'INSULATION
TOP OF TANK AT INTLET = 93.47
INVERT OF BUNG AT INLET = 92.76
ORIGINAL GRADE AT
HIGHEST POINT = 95.00
GEG T.H.#1
LOWER
MT CO
T
T
RELATIVE ELEVATION OF
BOTTOM OF T.H. = 79.00
DRY ON 6/16/21
NEW 1250 GALLON
H.D.P.E. GREER
SEPTIC TANK RATED
FOR 10' BURIAL
ORIGINAL GRADE AT
HIGHEST POINT = 96.5
FINAL GRADE = 95.5-95.9
r FILTER FABRIC _
INVERT OF PIPE = 89.00
BOTTOM OF TRENCH = 85.00
8'+
TOP OF TANK AT OUTLET = 93.47
T
4.0'
T
INVERT OF BUNG AT OUTLET = 92.67
UPPER
FINAL GRADE = 96.4-96.7
GEG T.H.#1
LTER FABRIC
INVERT OF
PIPE = 90.54
"5 BOTTOM OF
TRENCH = 86.54
RELATIVE ELEVATION OF
BOTTOM OF T.H. = 80.54
DRY ON 6/16/21 —
OF
��P.•
7N ,.77 a77 2�,.. , ,.-�:-.. �_�_..-� �.,... �� ..., _ _��..
•
............... ........................ 0
ENGINEERING � SALES - CONSULTING /
3701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK 99507 - PHONE (907) 337-6179FAX (907) 338-3246' WEBSITE: —.gam.—gmee(i q-. ,,,,, , , , „ A
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: kv
rn • . rey ••. •SS• •:• 4�tAr
STEVEN MCNEESE 907-360-1957 3 OF 3 06), CE -79,53 ° _�
LEGAL DESCRIPTION: DRAWN BY: \ •
SAND LAKE #2; BLOCK 2, LOT 13 & 14 D.J.G..;,,,,..•PROF(••.
TYPE OF WORK: DATE: LICENSE♦�� ESS` !.
� SEPTIC SYSTEM PROFILE 7/6/2021 #AECC884 �rra���►* /
VY9V71' NH(71N,71V aVVAI :IS 'A]E9 'Alf 11 FC --N.5
NI (171FJ07
(ZL-1zOZI6 Id) NOISIAM911S z oN YXV7 (INNS
zMao Im Iva Jo I
d3ANl7S.L71 WSV
,5Z = „I :ale:
KV :Rq umwC[
tuoo-srtaA_ nsjsuooNlo molaw :p u.ig
SLLV-#,E (LOO :x'Rd
5OS5-bb€ (L06) :aO!JJp
ZaS66'IV `3JVMOHJNV
HAY QNZ8 M STZ5
V 3NI.LSRIID V W N3A31S 3SUNalkl
90-4 (13HY93(d
WV W'DWM21D
30-ZI Q3.LVQdflr 8j(QZO1LO.23e([ AC WnS P[al3
afelogauV -aAV PuZB M 5I Z5 :ssajppV
Eer;uapss2-d :031S
8 I S66'C ISRIV `a'Bn.'OgOuy
41 aamS `p -d Susjnno(:I 9 L06
SSOA.inS uol;;)n.qsuo3 "sel V
SHNI7 -7ON9.d YOMMIt IGIff ` NIHS179VISY god QySIl Y8 NOHUyH dJ V(I ANV Q7I2OHS SNVIS 93 Nflily ,�
ON 2IHCINl2 JV7d CT3CWOD3y yHJ SO Y VZcfd V ION OQHOIHAt ENOIJMISHY dOSJNWN9A00
S.LNIN-VE V9 AN 90 ZONH.LSIX-7 3HI YXIM7JYQ OJ dYQ7II28 SIO Y3NAi0 SHJ .d0 A117I8ISNOJM 9HJ SI JI
SAIaIS1711OX3
'(73-1 ON SV l J-VOXV :LSM^.7 9, LN7NH,)VOYONJ ON M,Z GjV V 'NOIS ARyffnS Z
'ON U V7 QNb'S 'Z XOO78 'VE E107 �Jd.?dOYd JNIA107709 YH.L (T -VA YAVH ILMI ARJ,N--) A9VN.VH I
p
ag
l 1
0
X
m
Jm
t3OU7 019a 80
IIIIII
�kks
�tzz`t
I iidW d
{ •,� wiv
i o H�al9 O
MOLL V3MIJ ff2J I 7 SST
I�
�l
----------------------
AAV
---- _.— ._..-.—_And ❑ N Z8 IVB z
i
OVOM IVAS-d[HD i
Hanle
n � D
p �y �^Nr�?JIBJJ r r p■ T
,96*Pf All,PL iOJ o6NA
ov 4VO
j5 a9s,u
Z N0oIs
VIE 6 loI
ZE
,0 5z
A2i1N3 �
093 13AOO
Fw
laodado
N3dO
,Z'N
3snOH 3W"A N332i`J 9
w U00M Aao15 Z N a3lNrld I Ct
I a
.d'L6
V �
*13O aOQM � W
30NAA000M
❑vd
13AVHO m
6E m
3ON3jppOM
i86'$£I�u�'I.QS o6$S
5 4 101
LLL
QNnoi ONIH1oN
i a
ryrj ® -1 D�H�aIB
I�
n
`.z W
O
I�
C�Irn
all
II
31aHPJVW �
ry3
1
S3dld
M31GAS
OIld3S
®/
®
I
®®
I
I
�
I
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://avw.v.muni.oro/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP211173
Work Type: Septic Upgrade
Tax Code Number: 01113351000
Site Legal Address: SAND LAKE #2 BLK 2 LT 13,14 G:2224
Site Mailing Address: 5215 Nl 82ND AVE, Anchorage
Owner: MCNEESE STEVEN R & CHRISTINE A
Design Engineer: GARNESS ENGINEERING GROUP LTD
This permit is for the construction of:
Q Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy
Effective Date
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
Department
6/4/2021
6/4/2022
13500
❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received B)
Issued By:
C Q _11'r I See leter dotcj 6/17/0-1. °am K-"
Date: /* (vb I
Date: 6 2 f
0
P`
-_--- - Municipality of Anchorage
Depar
P.O. Box 196650 ® 4700 Elmore Road
Anchorage, Alaska 99519-6650 ® (907) 343-7904 ® Fax (907) 343-7997
http://www.muni.org/Onsite
Development Services Division
On -Site Water and Wastewater Proaram
x x x x VARIANCE/WAIVER REVIEW x x x
Waiver#: OSV211031 COSA#: Permit#:OSP211173
PID#: 011-133-51
Legal Description: Sand Lake #2 Bilk 2 Lts 13 & 14 AMENDED 6/17/21
Engineer: Garness Engineering Group
Your request for a waiver of the required 8' horizontal separation from the absorption field to the
existing absorption field has been approved. The approved separation distance is up to 0.0 feet.
See the engineer's letter dated 6/17/21. In addition, the field may be 5 feet from the north property
line.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-
site wastewater disposal system will require all separation distances be met or another approval
from this department.
Waiver is Granted: X Waiver is not Granted:
Date: 6 / 7/z- I Approved by:
Name of eviewo
**** VARIANCE/WAIVER REVIEW ****
MUNICIPALITY OF ANCHORAGE
Development Services Department` Phone: 907-343-7904
On -Site Water 8 Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 011-133-51
Property owner(s) STEVE MCNEESE
Mailing address 5215 W 82ND *ANCHORAGE, AK 99502
Site address 5215 W 82ND *ANCHORAGE, AK 99502
Day phone 907-360-1957
Legal description (Sub'd., Block & Lot) SAND LAKE #2; BLOCK 2, LOT 13 & 14
Legal description (Township, Range & Section)
Lot Size
Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
Fx_1
Initial ❑
Single Family (SF) El
(w/wo ADU)
Septic Tank
0
Upgrade Q
(D) ❑
Holding Tank
❑
RenewalDuplex
❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
N/A Distance: -
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 5C/5
Date of Payment: 5 D 2 i
Receipt Number: 17 `% 8' �
Permit No. 0S,P,2 0 1 %-3
Waiver Fees: 92.2.5
Date of Payment:61y121
,--
Receipt Number:QGr�hciG
Waiver No. 03UZ 1103 (
G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc
`•4
r i.•,
GARNESS ENGINEERING GROUP, Ltd
ENGINEERING SALES- CONSULTHLIG
r7
June Joh, 2021
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Proposed Septic System Upgrade for Sand Lake #2; Block 2, Lot 13 & 14
To whom it may concern:
During the layout it was noted that there is a large birch tree that is in the location of the proposed south
trench. Based upon this fact, we are requesting that your department issue a variance from drainfield to
lot line down to 5 feet. This will allow the trench to be outside this location and possibly preserve the tree.
Justification for granting this wavier is as follows:
Per MOA records, the drainfield on the lot to the north (Lot 15) is 10' from the south Lot line. In
short, our trench would not encroach upon the neighbors drainfield.
The trench for Lot 15 runs perpendicular to the lot line.
Additionally, per the initial design, we were proposing to install the drainfield below the existing field.
During the layout, the contractor exposed portions of the existing field. It was discovered that it is
approximately 1.2 feet out of level and a portion of the proposed drainfield effective would overlap with
the existing fields effective depth. It should also be noted that a seepage pit was found in addition to a
trench. We are requesting that you allow for the proposed drainfield be installed as designed, but that a
"dirt plug" be installed between the drainfields at the portions where the drainrock/s of the proposed field
and the existing fields overlap. Additionally, we are requesting that your department allow for a 4' dirt plug
where the proposed effective and existing effective would overlap that is not "in between" the two
proposed fields. Justification for granting this variance is as follows:
• Several areas of the existing drainfield have been exposed by the contractor. The bottom of the
existing system has been found to be higher than the bottom of the proposed system. In short,
they do not encroach on groundwater.
• During the excavation of the testhole, the soils were noted as an SM. In theory, this would serve
to "filter" the effluent more so than a gravel and/or GP type material.
We are unaware of any adverse impacts this installation or waivers would have on adjacent wells or
septic systems. If you have any questions, please contact us at 337-6179. Thank�ou for your
e
assistanc
... ...... :..
'.E., M.S. +V� J�irreya ca�noss�
t`0 PROFESS' O i
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211173, Deb Wockenfuss, 06/04/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211173, Deb Wockenfuss, 06/04/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211173, Deb Wockenfuss, 06/04/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211173, Deb Wockenfuss, 06/04/21
Municipality of Anchorage
`�✓� ue,,irrn,enc
P.O. Box 196650 ® 4700 Elmore Road
Anchorage, Alaska 99519-6650 ® (907) 343-7904 ® Fax (907) 343-7997
http://www.muni.org/Onsite
Development Services Division
On -Site Water and Wastewater Program
* * * * VARIANCE/WAIVER REVIEW * * * *
Waiver#: OSV211018 COSA#: Permit#:
PID#: 011-133-51
Legal Description: Sand lake #2 Blk 2 Lt 13 and 14 — AMENDED 4/12/21
Engineer: Pannone Engineering Services
Your request for a waiver of the required 100 feet horizontal separation from the absorption field
serving Lots 13 and 14 to the private well serving Lot 15 has been approved. The approved
separation distance is 98.0 feet. In addition, the field is approved to be 2.5 feet from the property
line.
This waiver approval applies to the existing absorption field only. Any future upgrade to the on-
site wastewater disposal system will require all separation distances be met or another approval
from this department.
Waiver is Granted: X Waiver is not Granted:
Date: 2 Approved by:
Name of Review
.......................................................... ...................
**** VARIAN C E/WAIVER REVIEW ****
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@panengak.com
March 25, 2021
Subject: Sand Lake S/D No. 2 Block 2 Lots 13/14
Well to Drainfield Waiver Request
Drainfield to Lot Line Waiver request
I am writing to request a Separation Distance Waiver be issued for the existing well on Lot 15 and the
existing wastewater disposal field on lot 13/14. The lot 13/14 are in the process of having the common lot
line removed. During the preliminary survey, it was discovered that a separation issue was existing. The
request for a waiver is to resolve the separation issue and bring this into compliance. The septic system on
lot 13/14 was installed in 1982. The well on Lot 15 was drilled in 1981 and deepened in 1984. In reviewing
recent water results for COSA's on lot 15 the nitrate levels have been consistently 0.1 -no nitrates
detected, even though this situation has been extant for 39 years.
a. Waivers - Drain Field (E) to Well (E): We would like to request a waiver for separation
distance for the existing septic system on Lot 13/14 to the well located on Lot 15. The distance
between the existing drain field and well is 98.7'±.
i. DEC Criteria: The well on Lot 15 is a private well and was drilled in 1981. The data is
summarized as follows:
LOT #
WELL
DEPTH
STATIC
WATER LEVEL
YIELD
Well Data
Date
H2O Test
Date
Soil
I Characteristics
Well Log
Data
Nitrate
Level
Lot 15
415'
115'
10+ gpm
03/05/1984
03/26/2008
1 Y
Y
0.1U
The ground water in this area typically flows from the northeast to the southwest. The soil
cross-sections are similar across the area and a homogenous cross-section was used to
calculate the DEC criteria for all components. As outlined under 18 AAC 80.020 and 18 AAC
72.021(a), I have calculated the following points:
Lot 13/14 Septic Svstem to Well:
Distance from sewer system bottom to groundwater
7.07
Soil sorption below sewage system
2.19
Soil permeability below the system
1.22
Water table gradient
6.00
Horizontal separation
2.76
Total Points
19.24
"The sum of the above values could equate to the following conditions: 16-24 Almost sure
to be free from any form of contamination from household sewage."
P.O. Box 13037, Palmer, AK 99645-1307
i elephone: (907) 745-3200 FAX: (907) 745-5201
Page 2 of 2
b. Waiver - Drainfield to Lot Line. The clean-out at the corner of the existing drainfield was found
to be 5.4 feet from the lot line. The drainfield is a 5 -wide drainfield and the clean-out is
assumed to be in the middle of the field. We request a separation distance waiver for an
existing absorption field to the lot line to two and a half feet (25). This is an existing drain field
which was installed in 1982 and upgraded in 1984. The field has been in operation since 1984.
Granting this waiver is not likely to affect the health and safety of this lot or the surrounding
lots now or in the future.
In my opinion, this waiver request meets the above criteria for approval and does not constitute risk to
health, and a waiver to the minimum separation distance should be granted.
The proposed installation will not affect the future development of the surrounding or existing lots.
If you have any questions or concerns, please contact me at (907) 745-8200.
Sincerely,
Steven R. Pannonei
a
e
i
°rAtlls®'�®O
Steven R. Pannone, P.E.
Owner/Civil Engineer
P.0, Box 1807, Palmer, AK 99645-1807
Telephone: (907) 745-8200 FAX: (907) 745-8201
0
N:
i�
V
L
O N N
L
;o
,o
O
N :
�
T
C
O
O
O
O
C
m
m
v o
.n v,
t� o
v
v
3 3 < o
w
4 ,
m m in
0 0
3
aj
S N
F
a =
� �
0 0 o m m m
Z
0 0 0
p o
m O O O
n
N
LD
1(.
0 0 0 0 °0000
N
IE
1� lD m N c0 O t0
0 o m o 0
000aoo n
oa00000aoo) 000000aoo
E
O
N
v
F
i�
d
L
;o
,o
p
0
s
N
N :
�
T
C
O
O
O
O
C
m
m
v o
.n v,
t� o
v
S900 00'00'E 135.00'
WOOD FENCE
O
O
O o w
SEPTIC SYSTEM qS z 34.1'
LL
ui
GRAVEL ¢ -
O
RISERS
O �
U
PAD � O
U O
O \ O O O
p LOT 14
WOOD FENCE
BLOCK 2 s
0 � —BIRCH
\
O
GM
6,750 SF hpRFF
O
vSFO
'LU
1 '
PLANTER
�
cli
o
N
GREEN F I' r, 7 — 7--1 1
O HOUSE
1
h � 54.0'
v J
32.7' o �+��
w LOT 13 �-
BLOCK 2 P
o-
U
0 0 61750 SF
o J
20.1'
BIRCHO
o
O
GRAVEL 191,
DRIVE
O
O
UnN90°
00' 00"W 135.00'
0 BIRCH
BIRCH � 4
O O o
SPRUCE BIRCH
0
CHIP-SEAL ROAD
0 82ND AVE
Adw �°F•••••.illl
AO '•9 ��
....... ... .....
r� :• MATT T. CROW
i •. 11597-S .• /
S� AW
11
0
11 OFESSIONA��Y,`�
17 Jul 2020
ASBUILT CERTIFICATION
I HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING PROPERTY, LOTS 13 AND 14, BLOCK 2, SAND
LAKE NO. 2 SUBDIVISION, AND THAT NO ENCROACHMENTS EXIST, EXCEPT AS NOTED.
EXCLUSIONS
IT IS THE RESPONSIBILITY OF THE O WNER OR B UILDER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS,
COVENENTS, OR RESTRICTIONS WHICH DO NOT APPEAR ON THE
RECORDED PLAT. UNDER NO
CIRCUMSTANCES SHOULD ANYDATA HEREON BE USED FOR ESTABLISHING
BOUNDARY OR FENCE LINES.
�A
Alaska Construction Surveys C�
Y � ►.J
_
Office: (907) 344 5505
907 E Dowling Rd, Suite 10 ALASKA
Anchorage, Alaska 99518 COsuxv Ys ON
Fax: (907) 344-4775
Email: mcrow@akconstsurveys.com
Site: Residential `
Drawn by: A.V.
Address: 5215 W 82nd Ave. Anchorage
Scale: V = 25'
Field Survey Date: 07/02/2018 *UPDATED 07-17-2020
Crew: M.C. & A.V.
ASBUILTSURVEY
PREPARED FOR
LOTS 13 AND 14, BLOCK 2
MCNEESE STEVEN R & CHRISTINE A
SAND LAKE NO. 2 SUBDIVISION
5215 W 82ND AVE
LOCATEDIN
ANCHORAGE, AK 99502
SEC. 23, 1] 3N, R3 W, SEWARD MERIDIAN, ALASKA
S90000'00"E 135.00'
173.0
I
\ BIRCH C
F_
W
NW
ry
vJ
X
O
U
J
1
_ 1
CHIP -SEAL ROAD JJ./ P,•• ••,• ,
o AW •
10 82ND AVE••••••010001
0 r ......................
.• MATT �+ T. CROW o ``� •. LS -11597 .• /
itl °ROfESSIONA�` A
PLOT PLAN 09 Jul 2018
I HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING PROPERTY, LOTS 13 AND 14, BLOCK 2, SAND LAKE NO. 2 SUBDIVISION, THAT
THE DRAINAGE PATTERNS AREAS SHOWN HEREON, ALL LOT CORNERS HAVE BEEN SET AND ALL DIMENSIONS HAVE BEENMEASURED
TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND ABILITIES.
EXCLUSIONS
ITIS THE RESPONSIBILITY OF THE OWNER OR BUILDER TO DETERMINE THE EXISTENCE OF ANYEASEMENTS, COVENENTS, OR
RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR
ESTABLISHING BOUNDARY OR FENCE LINES.
MATT T. CROW, LS 11597
Alaska Construction Surveys
907 E Dowling Rd, Suite 10
Anchorage, Alaska 99518
Site: Residential Lot
Address: 5215 W 82nd Ave. Anchorage
Field Survey Date: 07/02/2018
Crew: M.C. & A.V.
PREPARED FOR
MCNEESE STEVEN R & CHRISTINE A
5215 W 82ND AVE
ANCHORAGE, AK 99502
Office: (907) 344-5505
Fax: (907) 344-4775
Email: mcrow@akconstsurveys.com
Drawn by: A.V.
cale: 1" = 25'
PLOT PLAN SURVEY OF
LOTS 13 AND 14, BLOCK 2
SAND LAKE NO.2 SUBDIVISION
LOCATED 17V
NW ? SEC. 23, T13N, R3W, SEWARD MERIDIAN, ALASKA
We, the undersigned, add Lots 13 and 14 Block 2 Sand Lake
Subdivision #2 to the Articles of Partnership agreement concerning
that certain water system located�on Block one (1) Sand Lake
Subdivision #2.
There will be a monthly charge of $15.00 toward
the monthly electricity expense of operating the pump.
�/
William J. 1 ee, r.
Lot 12 Block 1
Sand Lake Sub. #2
STATE OF ALASKA
THIRD JUDICIAL DISTRICT
Kare/h V. Tiede
Lot 12 Block 1
Sand Lake Sub. #2
On this 11th day of June, 1981, before me personally appeared
William J. Tiede, Jr.. and Karen V. Tiede, known to me to be the
persons named in and executing the foregoing instrument, and they
acknowledged to me that they signed and sealed the same as their
-free and voluntary act and deed, for the uses and purposes therein
mentioned.
WITNESS, my hand and official seal the day and year hereinabove
written.
Nota y Pub' cin and for Alaska
My Commission Expires: /�l- 6
SvuTiiCr--ATeAL kEG1JiiAL LFFICE
437 "E" STREET, SUITS 'Go
AilCHURAGE, ALASKA 99501
June 19, 1984
274-533
mr. Glen mead
187.3 deutiow
Anchorages Alaska y9504
Dear Fir. i -lead:
Subject: Lots 13 ana 14, Block 2, Sand Lake #2 Subdivision
(8421 -UA -334)
We ilave reviewed tije as -built plans for the subject project. This letter
cclstiwtes final aNproval for the Wastewater systen modification.
Sincerely,
liames. F. )laydien
cnvironeental Fi6o Ufficer
J H'Aisn
MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
FEB 11989
RECEIVED
-
914 East 78th Avenue
ANCHORAGE, ALASKA r
r'
344 9242.
START
COMPLETE '
DAT
i
NAME
// //jt3
NO
}
ADDRESS'
t
k
CITY t �V
PJ -ONE
'!
i0e LocAnoN
TIME ,`
WELL LOG DEPTH
WELL LOG
z if �'�X
J'r: Nci yl rA�-� - �'.•�!r-Y`
�:.
,
-.� Safi t.
li��fw.,
'- rf� �M.
• ��'//r�
i
e'
c
e
,7
r
�.
y
•L.
i
1
p
Ez
StATIC LEVEL'
GPM »YIELD
,�yrr
�3
s .� u• s�iT2i�i t f �
�z 'rVr
�r5.
S
}!r
S
Received
STATE OF ALASKA
DEPARTMENT OF ENVIRONMENTAL CONSERVATION
APPLICATION FOR ON-SITE WATER AND SEWER
SYSTEM APPROVAL
I. GENERAL INFORMATION
Source of Water and Containment (Checkall that Apply)
Legal Description of the Location
,Lo`fs /3
!iW CornoF2 of'GUi �C G;nci 82�`�
wwell (Drilled or Driven) ❑ Surface (Identify)
Applicant Name
Ap licant is: (Check one) ,
Bank ❑Certified Installer No.
❑ Roof Catchment
❑ Other (Identify)
Owner/Builder
Address (Street or P. O. Box)
Type of Residence��
Total No. of Bedrooms
❑Other:
❑��
Single Family I{?Multi-Family
Well Data
City, State and Zip Code
Telephone
s�
a�
Send Approval to: ��•.� � � l
ElApplicant M`6'ther: (Give Name & Address)1.2t)n R3 /•'
r
II. WATER SUPPLY SYSTEM
Source of Water and Containment (Checkall that Apply)
Te of Water Supply System
yp
Treatment of Water (Check all that Apply)
wwell (Drilled or Driven) ❑ Surface (Identify)
❑�,/
Private
_
(�rvone ❑Chlorination
❑ Roof Catchment
❑ Other (Identify)
��
L7Public (Serves more than one
EJ Filtration ❑Mineral Removal
❑ Holding Tank
family)
❑Other:
Well Data
Is the Height of the Well Casing more than 12" above the Ground? ❑ Yes ❑ No
Is a sanitary seal installed on the well casing? ❑ Yes ❑ No
Is drainage directed away from or around the casing within a radius of 10 feet of the well casing?
❑ Yes ❑ No
Date Drilled
Depth of Well (Feet)
Static Water Level (Feet)
Yield (If Available)
Pump Rate (If Available)
Gal/Min
Gal/Min
Separation Distances from the Well Casing to each of the Following Sources of Contamination:
Septic/Holding Tank on Lot
Sewer Lines on Lot
Absorption Area on Lot
>I.SG
Closest Septic/Holding Tank on Adjacent Lot
Closest Sewer Lines on Adjacent Lot
Closest Edge of an AbsorptiomArea on Adjacent Lot
If toxic materials are stored on the property, including fuel tanks, paints, lubricants and other petroleum
On Lot -
On Adjacent Lot
based materials, pesticides, fungicides or herbicides, indicate distance from contaminants to well casing:
Water Sample Taken by: Name
Sampler is:
❑ Buyer ❑ Engineer
Address _
❑ Banker ❑ Government Official
Water Sample Results:
Attach Copy ❑ Satisfactory • Date: ❑ Unsatisfactory - Date:
Comments /Recommendations:
I certif that the above information is correct:
Signature - Typed/Printed Name
Title Date
NOTE. Must be signed by aCertified Installer, Professional Engineer. Department of Environmental Conservation or the Owner/Builder
III. WASTEWATER DISPOSAL
Date Installed
/
��,�� El Installer ❑ Other:
P--Owner/Builder
Septic Tank/Absorption System
No.
Package Treatment: -
❑ (Specify Brandand Name Process)
,
Nf
Soil Type or Rating
Z,B
?) 0 1:2
or
4
Holding Tank
❑
Capacity of Tank
r 1 6
Where Waste is Disposed f
Frequency of Pumping
Specify:
l[
NA:NxIck 's1
Percolation Test Results
N1,4
Percolation est b - (Name) I'
1 Nl4 ,
Septic Tank Outfall
❑ Discharged To:❑
Minimum Ground Cover over Septic
Tank
Other (Specify} -
Cleanout Pipes/Caps Installed on
Absorption System
I
Feet
(Outhouse, Incinerator, etc.)
Q/ Yes ❑ No
Gj�' New System — 6Lpc, tpj C -",o
Name of Installer
Gt
Date Installed
/
��,�� El Installer ❑ Other:
P--Owner/Builder
Type/Manufacturer
No.
Type/Manufacturer
Septic Tank Size (Gallons) Number of Compartments
Soil Type or Rating
Z,B
?) 0 1:2
/
Type Soil Absorption System
Dimensions/Size Soil Absorption System
Type/Quantity Backfill Material used for Soil
r 1 6
/ /
Abs ption Syste
;C1
d
r
NA:NxIck 's1
Percolation Test Results
N1,4
Percolation est b - (Name) I'
1 Nl4 ,
Minimum Ground Cover over Absorp-
tion area
Minimum Ground Cover over Septic
Tank
Cleanout Pipes/Caps Installed on
Septic TTalk
Cleanout Pipes/Caps Installed on
Absorption System
Feet
Feet
wyes ❑ No
Q/ Yes ❑ No
-
Separation
Water Supply Source on Lot
N earest Water Supply Source on Adjacent
Nearest Body of Water
Water Table/Bedrock
Lot Line
Distance to:I
�/ [) Feet
Lot
C) Feet
N,� .Feet
NItor Feet
/Q Feet
Comments/ Recommendations
r)pz_44clej s sk 7�>
AC joedpe�omS,
I certify that the above information is correct:
Signa reTyped/Printed
Name -
Title, Reg. /Cert. No., Inst. No.
Date
/OU Feet
L. bW eu My
�U Feet
Comments/ Recommendations
lot dfq
NOTE: Must6b signed bqqlC6rtffled installer, professional Ingineer or DEC Staff.
ltd" Existing System
Name of Installer 1
Date Install/ed
`Of
�-,/
IVJ Owner/Builder ❑Certified Installer ❑ Other:
Type/Manufacturer
No.
Septic Tank Size (Gallons) Number of Compartments
Soil Type or Rating
T pe Soil Absorption Sys?6m
r /
DimensionVSize Soil Absorption System
Type/Quantity Backfill Material used for Soil
I
(
( /
Absorption Syste
NA:NxIck 's1
Adequacy Test Results:
❑ ❑ OrA-
Adequacy st Perf rmed By: Attach Copyof Repo )
h)(.+
Date Septic Tank Pumped (Attach Copy of R ceipt
Pass Fail
Minimum Ground Cover over Absorp-
Minimum Ground Cover over Septic
Cleanout Pipes/Caps Installed on
Cleanout Pipes/Caps Installed on
tion Area
-T
Tank
Septic Tank
Absorpt on System
Feet
Feet
Yes No
es ❑ No
Separation
Water Supply Source`�o/ mat-
CC
Nearest Water Supply Source � Adjacent
Lot
Nearest Body of Water
Watgr Ta Ip/Bje rock
Lot Line
Distance to:
/7,2 Feet
(� Feet
/OU Feet
T f£Q
pr% Feet
�U Feet
Comments/ Recommendations
lot dfq
r J
C(S S�S k tiv/ c�c�tt,� z&. (f.Q�V (C OC)OP_, WAS C1Cl ` dt1 .
certify that the above information is correct:
Signature
Typed/Printed Name Titl No.
Date
�+ eee••e•.eof.
NOTE: Must be signed by a professional engineer. •� ee
* jdOTM JM 0 *
pclj C. Reid, Jr. ; >-
.2251•F
�a
eq'stered Professional
AFESS�� P.�� Engineer
MUNICIPALITY OF ANCHORAGE
• �e DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 264.4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME
/C^
PHONE
EW
f p - // ('
_ (' (
❑ UPGRADE
MAILING ADDRESS
LEGAL DESCRIPTION
1 dt t a i R-2 s, ��K£ z
LOCATION
NO. OF BEDROOMS
U Y
DISTANCE TO:
Well 'I
T
Absorption area
+��
Dwelling
'!
7iS�
PERMIT NO.
Cj�U
(J
1—Z
Manufacturer
Material
No. of compartments
Liq. capacity in gallons
IF HOMEMADE: Inside length
._
Width
Liquid depth
_
z
DISTANCE TO:
Well
Dwelling
PERMIT NO.
= z F
Manufacturer
Material
Liquid capacity in gallons
w=
Well
DISTANCE TO:4(5-o(
Foundation Nearest lot line
cor /[' /
PERMIT N0. //
aC�8S1'S�
Lu LL Z
I a n
No. of lines Length of each line
°� // 2 a
Total length o� Iipes Trench width /
6 S
Distance betvyeen lines
_,�z
Top of the to finish grade
nehes
Material beneath the
/ r
Total fecctive absorption area
w
C inslaes
(p'�
w
Length Width
Depth
PE MIT NO.-
C7
—�
i F
W°
LU
Type of crib
Crib diameter
Crib depth
Total effective absorption area
W
DISTANCE TO:
Well
Building foundation
Nearest lot line
_j
w'n��
ass r r
Depth
Driller
Distance tp lot line
PER IT N =
DISTANCE TO:
Building{f
Sewer lin
Septic tangy
Absorption area(s)
(Sut
/
a
OTHER
"
PIPE MATERIALS
D 3o3'
SOIL TEST RATING
S-D
C
J
INSTALLER
REMARKS
J J 2 FZ n12AU
'
�D ?
S
p(
17`
n's
is
eH'1
ILLILLJ
APPROVED DATE LEGAL
/�
/ f -2—
MU"lR::-*l,F-::_'nl I_rV OF=
-lot 0-0
DEPARTMENT HEALTH AND ENVIRONMENTAL ROTECTION
825 'L' STREET, ANCHORAGE, AK. 99501
264-4720
I -FE: F=l'E:Fz_-Ml-F-
/� �"
PERMIT NO. 820894
APP 'LICANT GLENN G MEAD 521514 82ND AVE 99502
21el
LOCATION L Lnl s?,) / I Lt)
JK
LEGAL L14 82 SAND LAKE #2 LOT SIZE 99999,
SQU
TYPE OF SOIL ABSORPTION SYSTEM IS:!, DRAINFIELD
MAXIMUM NUMBER OF BEDROOMS 4 SOIL RATING (SQ FT/BR)= :150
THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS:
_/}".
THE LENGTH CII
THE DEPTH
RAINF E D.
tL �
OF
GROUND AND THI
E OF T(Er
THE
GRAVEL DEI
PALL PIPE
AND THE BOTTOI
E_= AD u I F-0 F= C-4
b2- a soz
PERMIT APPLICANT �
F41 1 0 r_4
INSTALLATION
DURING THE
INSI
D THE
NUMBER OF RESIDEI 0
j jr
-rwcl
F?
BROKFILLING OF Al
THIS
DEPARTMENT WILL L �__
MINIMUM DISTANCE BETWEEN R WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM Is
100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC WELL.
MINIMUM DISTANCE FROM A PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET AND
TO A COMMUNITY SEWER LINE IS 75 FEET.
OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE
AVAILABLE TO INSURE PROPER INSTALLATION.
F:n'EFS* t-1 11 _F E:eo.F=o I FRE_. 0,E:l:_E=lr-l�F=F;,: _. -_=®e=:
o_D:=_o
I CERTIFY THAT
1: 1 AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: 1 WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
3: 1 UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THAN 4 BEDROOMS.
SIGNED: -
APPLICANT GLENN G hfEA
ISSUED BYQ:�__
A
!°
POUCH 6-650
ANCHORAGE. ALASKA 99502-11650
(907)264-4111
TONY KNOb7LES.
'VA YOR
DEPARTMENT OF HEALTH AND ENVIRONMENTAL_ PROTECTION
January 4, 1982
Glenn G. Mead
1333 West 25th Avenue
Anchorage, Alaska 99503
Permit # 810525 5ln 'Z'
Subject: Lots 13 and 14 Sand Lake Subdivision #2
A permit issued by this department for a well and/or sewer
system has expired as of December 31, 1981.
Permits are issued on a calendar year basis, as stated on
the permit, by authority of Municipal Ordinance.
If you have drilled the well, a well log should be sent to
this department to document the installation date.
If an engineer inspected the installation of the on-site
sewer system, please have them send us the as-builts for our
files.
-_ ;__. _ er
Les N. Buchholz R.
Program Manager
Sewer and Water Program
Enclosure: Copy of Permit
TYPE OF 'SOIL. ABSORPTION SYSTEM IS: F:RAIMFIELD
MA,--, I Ptl_!M NUMBER OF BEDROOMS -_ 4 SOIL RATING (9-7! FTe BR) =• 2:18
THE REQUIRED SIZE OF 'THE SOIL ABSORPTION SYSTEM IS:
8__ 1:3 -T'" = _-L CD :2 Ail FZ 4=� �_ F" -T- 1--1-- _
THE LENGTH DIMENSION I • ' THE LENGTH -(IN FEET) OF THE TRENCH OR DRA I NF I ELD.
THE DEPTH OF F! TRENCH OR PIT IS THE DISTANCE BETWEEN 'THE SURFACE OF THE
GROUND AND THE BOTTOM OF THE EXCAVATION r*IN FEET?.
_T_ 9-1 Ev I- fi" E_: r-4 A_ : E-A 0-4 I E: _T` t --I I; "� - a.= 19.1 t�-9 F__ -ir
THE GRAVEL. DEPTH I 'THE MINIMUM DEPTH OF GRAVEL BETWEEN 'THE OUTFALL F'IF'E
AND THE BOTTOM OF THE E<<.C:A'•• ATION (IN FEET).
I =.E=.:F_°-r 3: A. - F=l P -A --- -=a T ;E FE
PERMIT APPLICANT HAS 'THF_ RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE
INSTALLATION INSPECTIONS OF AP'd'r WELLS ADJACENT TO THIS PROPERTY FIND THE
NUMBER OF RESIDENCES 'THAT THE WELL WILL ERRE.
— ..__ •--- -T-1"-19_@ .- "_ > I P'•I -_ F° F= Aw • 'T- _6- CA r -J "—° FA F^? E= F --?E7 . !_:-a LJ 11'u._ E-=. E -a
BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL- E"r' THIS
DEPARTMENT WILL BE: SUBjEC:T TO PF=OSECUTION.
MINIMUM DISTANCE BETWEEN A WELL. AND ANY ON --SITE SEWAGE. DISPOSAL SYSTEM 15
100 FEET FOR ,A PRIVATE WELL. OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC WELL.
MINIt'IUM DISTANCE FROM A PRIVATE 14ELL TO A PRIVATE SEWER LINE IS 25 FEET AND
TO A COMMUNITY ' E14ER LINE IS 75 FEET.
OTHER REQUT REMENTSMIAY APPLY. SPECIFICATIONS AND E::UNSTRUC:TION DIAGRAMS ARE
AVAILABLE TO INSURE PROPER INSTALLATION.
l_" E=_ Via=_ L"°*l lE -T" BE 4-< 4-.'° :T r ---"F= ^ ra E-7- A._- Ew 1--1 E — F:- .., -- j ." ::L °__I � 3 -
I CERTIFY THAT
1: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE :=:EWERS AND WELL__ AS SET
FORTH BY 'THE MUNICIPALITY OF ANCHORAGE.
_..: I WILL INSTALL ALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
_ . I UNDERSTAND THAT' THE ON --SITE SEWER 4'STEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THAN 4 BEDROOMS.
I GNED : _ _.,,�_ .__ ._____.________.____
AF='F'L GLENN MEA.i
I .°-?_!E[:=' DATE-.--Gt J._. _... V4. 0
yti e'; l l 7 o
1.4"PHRTMENT
•. HEALTH
AND ENVIRONMENTAL jTEi_TIOtJ
825
` L ` STREET,
ANCHORAGE, AK.
264-4720
PERK IT
NO. :: 10525
APPLICANT
GLENN G. NEAR
!.J. 25 AVE S b z
279-0991
LOCATION
5215 W. 82ND
LEGAL
L138.14 B_ 'SAND
LAKE #2'
LOT SIZE ; 00CI
SQUARE FEET
TYPE OF 'SOIL. ABSORPTION SYSTEM IS: F:RAIMFIELD
MA,--, I Ptl_!M NUMBER OF BEDROOMS -_ 4 SOIL RATING (9-7! FTe BR) =• 2:18
THE REQUIRED SIZE OF 'THE SOIL ABSORPTION SYSTEM IS:
8__ 1:3 -T'" = _-L CD :2 Ail FZ 4=� �_ F" -T- 1--1-- _
THE LENGTH DIMENSION I • ' THE LENGTH -(IN FEET) OF THE TRENCH OR DRA I NF I ELD.
THE DEPTH OF F! TRENCH OR PIT IS THE DISTANCE BETWEEN 'THE SURFACE OF THE
GROUND AND THE BOTTOM OF THE EXCAVATION r*IN FEET?.
_T_ 9-1 Ev I- fi" E_: r-4 A_ : E-A 0-4 I E: _T` t --I I; "� - a.= 19.1 t�-9 F__ -ir
THE GRAVEL. DEPTH I 'THE MINIMUM DEPTH OF GRAVEL BETWEEN 'THE OUTFALL F'IF'E
AND THE BOTTOM OF THE E<<.C:A'•• ATION (IN FEET).
I =.E=.:F_°-r 3: A. - F=l P -A --- -=a T ;E FE
PERMIT APPLICANT HAS 'THF_ RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE
INSTALLATION INSPECTIONS OF AP'd'r WELLS ADJACENT TO THIS PROPERTY FIND THE
NUMBER OF RESIDENCES 'THAT THE WELL WILL ERRE.
— ..__ •--- -T-1"-19_@ .- "_ > I P'•I -_ F° F= Aw • 'T- _6- CA r -J "—° FA F^? E= F --?E7 . !_:-a LJ 11'u._ E-=. E -a
BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL- E"r' THIS
DEPARTMENT WILL BE: SUBjEC:T TO PF=OSECUTION.
MINIMUM DISTANCE BETWEEN A WELL. AND ANY ON --SITE SEWAGE. DISPOSAL SYSTEM 15
100 FEET FOR ,A PRIVATE WELL. OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC WELL.
MINIt'IUM DISTANCE FROM A PRIVATE 14ELL TO A PRIVATE SEWER LINE IS 25 FEET AND
TO A COMMUNITY ' E14ER LINE IS 75 FEET.
OTHER REQUT REMENTSMIAY APPLY. SPECIFICATIONS AND E::UNSTRUC:TION DIAGRAMS ARE
AVAILABLE TO INSURE PROPER INSTALLATION.
l_" E=_ Via=_ L"°*l lE -T" BE 4-< 4-.'° :T r ---"F= ^ ra E-7- A._- Ew 1--1 E — F:- .., -- j ." ::L °__I � 3 -
I CERTIFY THAT
1: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE :=:EWERS AND WELL__ AS SET
FORTH BY 'THE MUNICIPALITY OF ANCHORAGE.
_..: I WILL INSTALL ALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
_ . I UNDERSTAND THAT' THE ON --SITE SEWER 4'STEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THAN 4 BEDROOMS.
I GNED : _ _.,,�_ .__ ._____.________.____
AF='F'L GLENN MEA.i
I .°-?_!E[:=' DATE-.--Gt J._. _... V4. 0
yti e'; l l 7 o
GREATER ANCHORACL AREA BOROUG1. \
a HEALTH DEPARTMENT CASE ,V
I � 327 EAGLE STREET
I ANCHORAGE, ALASKA 99,501
Performed For����i C�ZJ Date Performed ���� /C-
Lega:. De scriptl-on : Lot �`ulock Sut�dyl 7=1 oil (lL�
'•.I,�ox,ts a: Soa.i.s Leg-. .pereolation Testi
Dep' h
''ee Soil Chavac.`1erist%cs Location Sicetc'r.
T& se/7 c ohcl,
Yrrk /I -C 1-171.!; 'ire)
The hvrr"zovr centa.c is
%re da l,onc /, ///P C�,
11/1d s,'// con l el? l i7
O el' j errs 116, The/P
Guy/S' Gt /6�t/ .is?d:SfGr/�
7// ,/ 111-e
l / Ll /Psi r'G f )d aorb
6Y/D✓-� Ca���/� �f,
Was Ground Water Encountered?
If Yes, At What Depth
Proposed SnstalTat'aon -- >�
eepage pit [s - Drain Field
Depth Of Inlet
COMMENTS: ,)eptn To Bottom Of Pit Or 'i'renc
/ / � E2 s7 / ri e C A /
AM
4),
Test Performed By, "^ -
Datta Certified By.
DateL"" --»�
As od1z-r
I
licam,
IyII/
s
u
N59a55'45" W 135,0
lets Pur
11
L
j
O< his
N M
'
/4.L j)CCK•
c
i i
n �
.l7•s
X7.0
,11
Faarr� M
N
0
Or
3Z.t
r
o
�
L;4:
I
13
m
ml
5' 45'1 W 1'55.0
q- W, v2 N!' AV5. _
sreby certify that I have surveyed the following described property, Lots 1L- 1¢ I;t,ock 2
3ition 111) LAK£ 511'8 41 2 , %/rJ<' q, recording Precinct, Alaska, and that the
rovsmonts situated thereon are_ within the property lines and 'do not overlap or encroach
the property lying adjacent thereto, that no improvementson property lying adjacent thereto
roach on the promises In question and that there are no roadways, transmission lines or
or visible easements on said property except as indicated hereon.
irharago, Alaska OV ( MA Y '1 � 72
U)
7LA
z"4 4
Qa
,a9C'.)�.' �z;,.-.Ti ti's .J
��� lOj,.�iM' �� • �
�ey�DD.N�N •U •••••pN.be.C•
¢1
04
"naeS SU��
`�Yr yL V
MUMUFAN UTY OF A HC HOR%AGE
Development Services Department Phone. Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 011-133-52-000
Expiration Date: 8/2/2023
Legal description SAND LAKE #2 BLK 2 LT 13A
Site address 5215 W 82ND AVE Anchorage AK 99502
Current property owner(s) MCNEESE STEVEN R & CHRISTINE A
X The On-site system(s) is/are approved for 4 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
3Z
Original Certificate Date: 5/2/2023
his Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist
Absorption Field Advisory
Tank Age Advisory
Other
X Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
x
COSA Approval June 2022
MUNMPALITY OF ANCHORUSF
Development Services Department
On -Site Water & Wastewater Section
Phone: 907-343-7904
Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 011 -133 -
Complete legal description Sand Lake #2; Block 2, Lot 13A
Location (Site address) 5215 West 82nd Avenue *Anchorage, AK
Current property owner(s) Steve MCNeese Day phone 907-229-5047
2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS
3. TYPE OF WATER SUPPLY: JN -1? ivate-Welk ❑ Private Well serving 2 dwelling units
cf� Private Well serving 3+ dwelling units ❑ Community Well or Public
R ❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: FE -1 Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ❑ Steel 0 Plastic ❑ Concrete ❑ Fiberglass
Age <2 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench * Wide Trench ❑ Seepage Pit
Waiver request for:
Expedited review requested: ❑
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee
Date of Payment
COSA #
Waiver Fee $
Date of Payment
Waiver #
COSA AppIlcaUon June 2022
Al.
COSA Checklist - �
Legal Description: Sand Lake #2; Block 2, Lot 13A Parcel ID: 011 -133 -
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system _
AWELL DATA SUBJECT LOT IS SERVED BY A "SHARED WELL" "LOCATED ON SAND LAKE #2; BLOCK 1, LOT 12
.
❑ Well log is filed with Onsite (or attached)
Date drilled Total depth f
Cased to ft
❑ Sanitary seal is functio ' g correctly
❑ Wires are prope protected
Casing heig bove ground) in.
Date o w test for COSA
is water level at beginning of test ft.
Comments
:=:g
;t;a
at time of t tj�5m'
nkvolume gallons
Well disinfected for coliform test? ❑ Yes ® No
Coliform bacteria is Negative
Nitrate mg/L ENitrate less than MRL (ND)
Arsenic)�"3- • I ug/L ❑ Arsenic less than MRL (ND)
Collected by GEG
Date 3/28/2023
B. TANK DATA C. LIFT STATION
Measured operating fluid level in septic tank 58.5°❑Required mainten completed
Date of pumping 4 17-12-3 Age of lift stati years
❑ Required maintenance completed, if AWWTS Lift stat' material
Comments: ments:
D. ABSORPTION FIELD DATA UPPER/LOWER TRENCH
Which system tested (date installed) 6/22-23/21
Adequacy test date N/A
❑ ALL standpipes present per record drawing
Results Q Pass
Total measured depth from grade 1016"0.9 ft (max)
Fluid depth prior to test - in
Measured depth to pipe invert from grade 5.86/6.5 ft (min)
Water added - gal
❑ N/A - pressurized field.
New fluid depth - in
❑ Per record drawings, field is insulated.
Elapsed time - min
0 Monitor tubes go to bottom of effective.
Final fluid depth - in
If not, state depth into effective
Absorption rate 600+ gpd
❑ Presoaked required if
FIELD STATUS - POST RECOVERY
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Effective depth (per record drawings) 48/48 in
Gallons introduced N/A gallons date
Effective depth used 14 in
Any rejuvenation treatment (past 12 months)
Effective depth remaining 34 in
If yes, enter date N/A
Comments/Deficiencies: DATA TAKEN FROM GEG INSPECITON REPORT. PER GEG INSPECITON ON 3/28/23 THE LIQUID LEVEL IN
THE NORTH (LOWER) TRENCH WAS 14 INCHES AND THE LIQUID LEVEL IN THE SOUTH (UPPER) TRENCH WAS 13 INCHES.
COSA Checklist June 2022
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100'
Community Sewer Manhole/Cleano _
Yes
if No
ft
Yes
if No ft
Neighboring Tank > 100' Yes
if No
ft
Private S eptic Line > 25' ❑ Yes
if No ft
Absorption Field on Lot > 100' ❑ Yes
if No
ft
olding Tank > 100' ❑ Yes
if No ft
Neighboring Absorption Fields > 100'
Animal Containment > 50' ❑ Yes
if No ft
es
if No
ft
Manure/Animal Excreta Storage > 100'
Community ain > 75' ❑ Yes
if No
ft
r] Yes
if No ft
❑ N/A - Served by Community
Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10' f -E-1 Yes
if No
ft
Surface Water > 100' Yes
if No ft
Tank to Property Line > 5' r■ Yes
if No
ft
Wells on Adjacent Lots:
Field to Property Line > 10' ❑ Yes
if No *51+
ft
Private Wells > 100' Yes
if No ft
Water Main > 10' p■ Yes if No ft Community Wells > 200' n Yes if No ft
Water Service Line > 10' FE Yes if No:_DIf tank or field is under driveway comment below
F. ENGINEER'S COMMENTS A'J StA� �.� ,n d i.v C.L' n�1
*WR#OSV211031Q�, L 12
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm Gamess Engineering Group, LTD. (GEG) Phone 907-337-6179
Engineer's Printed Name Jeffrey A. Gamess Date
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in
accordance with the guidelines and regulations established by the Municipality of Anchorage and industry
practices. The reported results describe the condition of the system/s on the date/s of the evaluation.
Separation distances were measured to readily identifiable features. Hidden defects or encroachments may
exist that were not identified during the evaluation. The operational life of all wells and septic systems depend
upon a variety of variables, including (but not limited to) soil conditions, groundwater levels (that may fluctuate
during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing
the systems. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not
guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding
the future performance of the well or septic system. GEG makes no representation whether an alternative well
or septic system can be installed on the property in the event either of the current systems fail to perform
adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG
to perform the evaluation. Reliance upon the information provided in this report by any other person or party
(including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever.
COSA Checklist June 2022
;Z&C 84
a J77
s�
,(;// /z
133�JiS XOOjjM
MAZZMMMA�� Myl
31VO 1/0
ui
0
z
uj
U- rN,
0
0 cv)
3: 1
ft�
00
*s
w
ou
00
z
w
LL
0
0
i
U. 0
00
zo
C4
Lo
00
0
—J
133�JiS XOOjjM
MAZZMMMA�� Myl
31VO 1/0
ui
0
z
uj
U- rN,
0
0 cv)
3: 1
I I
6,F*00[ .7jj'OO i 00 oOA[
10-1 z � 10-1
Awl
00
F— U-)
Oo
CD
Aow
0
AIMW
,qo
0
<
4*n C� 0
0 co ry
o
d.
00
CLs
i;oo
-3/HO--3/HO-3/HO-3/HO-3/HO-3/HO 3/HO-3,
ou
00
i
U. 0
00
zo
LO
*..#
CV)
IVL
0
>-
W F -
30N3-4 1/0
0 w
C�e
LU
cn
- -----
0 Zo
W)
wG
- --- -----
CK
ui
-- ----
w CL
04
n3
k 70(7
3:0
co
Lli
F-
W -co
> W
il
0-
0
z
CL
U)
Z
D
LL w Z LLJ
(D F-
o
oo
w
z z Ix 0
< 0
----- — — — — — — — — —
IWS3 3VI 0 �
0— �.
z .... .. — — — — —
3/HO-3/H0-3/H0-3/HO-3/HO�3/HO(q-3/HO—I/HC-3/HO-3/HO—
I I
6,F*00[ .7jj'OO i 00 oOA[
10-1 z � 10-1
Awl
00
F— U-)
Oo
CD
Aow
0
AIMW
,qo
0
<
4*n C� 0
0 co ry
o
d.
00
CLs
i;oo
-3/HO--3/HO-3/HO-3/HO-3/HO-3/HO 3/HO-3,
0 pow
*..#
C�e
cn
wG
Arsenic Advisory
Certificate of On -Site Systems Approval # OSC231089
Subdivision: Sand Lake #2, Block: 2, Lot: 13A
A water sample revealed an arsenic concentration of 22.1 micrograms per liter
(ug/L). The Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While
private wells are not subject to this regulation, EPA standards are based on existing
health information and can therefore be used to gauge the relative quality of water
from private wells. information on arsenic is available from the On -Site Water and
Wastewater Program website (www.muni.org/onsite) or at 343-7904.
This advisory must be attached to all copies of the subject Certificate of On -Site
Systems Approval.
Mailing Address P O Box 196650 * Anchorage; Alaska 99519 6650 *www muni org
MUNICIPALITY OF ANCHORAGE
• Department of Health & Human Services
DIVISION OF ENVIRONMENTAL SERVICES
343-4744
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF
ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING
Parcel I.D. # D/%—/ >�— /> z/z/ HAA # X//f8-_ 92T,
1. GENERAL INFORMATION (Must be completed prior to submittal)
(a) Legal Description (include lot, block, subdivision, section, township, range)
X07' /3 -/1/ $1-0M z s*A 4,� '*�Z 7_/ 7,A1 X 14
Location (address or directions)
(b) Property owner f%u� Telephone: (home)
Mailing Address
(c) Lending Institution
Telephone
Business
Mailing Address
(d) Real Estate Company and Agent
Address 5Ft°S e
Telephone
?Wf /7/7
(e) Mail the HAA to the following address: (or check here,, if hold for pick up.)
List contact person and day phone number below:
/SEGS ?lee uP
2. TYPE OF RESIDENCE
Single -Family Number of bedrooms S
3. WATER SUPPLY
Individual Well ❑ CommunityX Public ❑
Note: If community well system, must have written confirmation from the State Department of Environmental
Conservation attesting to th legality and status.
4. SEWAGE DISPOSAL
On-site X Public ❑ Community ❑ Holding Tank ❑
Note: If community well system, must have written confirmation from the State Department of Environmental
Conservation attesting to the legailty and status.
72-025 (Rev. 7/88) Page 1 of 2
L 13 -i /if i3 i. -W, 1446 'Otz-
5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this
Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe,
functional .and adequate for the number of bedrooms and type of structure indicated herein. I further verify that
based on the information obtained from the Municipality of Anchorage files and from my investigation and
inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and
State codes, ordinances, and regulations in effect on the date of this inspection.
Name of Firm AEGf Telephone
Address /�ly /J 33c_� ""ell /`}1 915-4j
Date Z"/ -V7
6. DHHS APPROVAL
Approved ford—bedrooms by
Approved X— Disapproved
Terms of Conditional Approval
Ag
0
j. '•00
u
f `
6
CE - 2251 e� F
Date —
Conditional
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval
cerificated based only upon the representations given in paragraph 5 above byan independent professional engineer
registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending
institutions in orderto satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections
or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions
in the professional engineer's work.
72-025 (Rev. 7/88) Back Page 2 of 2
MUNICIPALITY OF ANCHORAGE (MOA)
MUN• Health Authority Approval (HAA)
F ANH 46MCKLIST - FEBRUARY 1984
ENVIRO NTAL PROTECTION
HEALTH � 343-4744
-
Legal Description: /-eT /3 —/s'/ ;t3mo Z
E 8 1 1989 spa ot-i
A. WELL DATA RECEIVED
Well Classification CehN•
Log Present(Y/N)
Cased to
Static Water L�u�
Casing Height Above G and
Electrical Wiring in Conduit
Date Completed
SEPARATION DISTANCES FROM
To Septic/Holding Tank on Lot
Depth of Grouting
To Nearest Edge of Absorption Field on Lot
To Nearest Public Sewer Line
To Nearest Sewer Service Line on Lot
Water Sample Collected by
Water Sample Test Results
Comments
If A, B. C, .E.C. Approvedr'�1 N)
Yield
Pump Set At
Sanitary Seal on Casing (Y/N)
Depression Around Wellhead (Y/N)
; On Adjoining Lots
On Adjoining Lots
To Neareslublic Sewer Cleanout/Manhole
Date
V
B. SEPTIC/HOLDING TANK DATA \
Date Installed 6 4 Size /�� No. of Compartments \
Standpipes (YiN) Air -tight Caps 0N) Foundation Cleanout (Y6)
Depression over Tank (YuN Date Last Pumped /JAGS
Pumping/Maintenance Contact on File (Y/N) ; for IJ114
Holding Tank High -Water Alarm (Y/N) 444 Temporary Holding Tank Permit (Y/N) /!
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK:
To Water -Supply Well /%Z To Building Foundation %
To.Property'Line /O r�" To Disposal Field s
To Water, Main/Service Line
i
To Stream, Pond, Lake or Major Drainage Course
Comments
72-026 (Rev. 7/88) Front
Page 1 of 2 CL lupLw_Q
i - j10 -k3 > ] r'PG_
4J-'�
1_04,7z- SAS low -lL
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata /Sd Type of System Design
Date Installed /d /9��L �i "b' 8� Length of Field /Oio
Width of Field
Depth of Field
Gravel Bed Thickness
Square Feet of Absortion Area i13 Statndpipes Presen(Y N)
Depression over Field (Ye Date of Last Adequacy Test /Z " 7-rr
Results of Last Adequacy Test �EQuf1�6 �� S B�KfiS.
3/
SEPARATION DISTANCE FROM ABSORPTION FIELD:
01
To Water -Supply Well
To Building Foundation
Lot
To Water Main/Service Line
To Property Line
To Existing or Abandoned System on
On Adjoining Lots /O -,A-
To
To Cutback (if present)
To Stream, Pond, Lake, or Major Drainage Course _
To Driveway, Parking Area, or Vehicle Storage Area
Comments
D. LIFT STATION
ZInstalled
in Gal o
"Pump On" Level at
High Water Alarm Level at
Tested for
Meets MOA Electrical Codes (Y/N)
Comments
Dimensions
Manhole/Access (Y/N)
`*Check Permitted Bedroom Rating Against HAA Request'
"Pump Off" Level at
Vent(Y/N)
Pumping Cycles during Adequacy Test.
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this
inspection. VOWA
Signed g ,�� OF A 6
Company ,'fie TH ng rVf Seal
Date ; * t
MOA No. D
Receipt No. 4QS � �-yz;
Date of Payment
Amount: $�
iAll
r
1 e MR C. REID, JR. f
o
Ci -2251
Al
Receipt No. 404
Waiver Fee: $
Date of Payment
72-026 (Rev. 7/88) Back Page 2 of 2
5. LEGAL DESCRIPTION
DoT
DATE RECEIVED
INSPECTION APPOINTMENTS
_S#ql_\dleAlCe- -42
TIME
TIME
TIME
DATE
DATE
DATE
INSPECTOR
INSPECTOR
INSPECTORh/��
MUNICIPALITY OF ANCHORAGE
MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH &
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTI9MVIRONMENTAL PROTECTION
825 L Street - Anchorage, Alaska 99501
•
jliN
ENVIRONMENTAL SANITATION DIVISION
Telephone 264-4720 RR EEc vv
OF INDIVIDUAL WATER AND SEWER" Ck�' 0
REQUEST FOR APPROVAL
DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing.
1. PROPERTY OWNER
PHONE
depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
MAILINGADDRESS _ nn
F
PROPERTY RESIDENT (If different from above)
PHONE
❑ PUBLIC UTILITY
2. BUYER
j 5' a w �- C- e Ck r
PHONE
3 7) ��
-MAILI GiADDRESS
A;�':.;� Cr�v-Lal( Pl�r�
-3;--LENDING INSTITUTION
PHONE
L Sic FJ- N U F GDY" n.q e --r c e
7L 07 r9--0
MAILING ADDRESS
'( e" _:�-t r e Lo 7-
4. REALTOR/AGENT
4.
PHONE
rn)qr-((-?lam
MAILING ADDRESS "
V'lqa 6USinP5_5 PGr'
5. LEGAL DESCRIPTION
DoT
62-
_S#ql_\dleAlCe- -42
STREET LOCATION
-a ,5-
uj 0S i
6. TYPE OF RESIDENCE
NUMBER OF,BEDROOMS
❑ One ❑ Four ❑ Other
❑ SINGLE FAMILY
❑ Two ❑ Five
g- MULTIPLE FAMILY
❑ Three Cl Six
7. WATER SUPPLY
-
❑ INDIVIDUAL* *
ATTACH WELL LOG. A well log is required for all wells drilled
- CZ COMMUNITY •
since June 1975. For wells drilled prior to that date, give well
❑ PUBLIC UTILITY
depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
-
❑ INDIVIDUAL/ON-SITE**
YEAR ON-SITE SYSTEM WAS INSTALLED.
❑ PUBLIC UTILITY
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010 (Rev. 6/79)I
C..� �i a-� s tw G' ,iweas Pte--
La
F
THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE
O SINGLE FAMILY
D MULTIPLE FAMILY
NUMBER OF BEDROOMS
O ONE D THREE O FIVE O OTHER
D TWO D FOUR O SIX
2. WATER SUPPLY
D INDIVIDUAL
D COMMUNITY
D PUBLIC UTILITY
Connection Verified
PERMIT NUMBER
DEPTH OF WELL
DATE DRILLED
LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM
DINDIVIDUAL/ON-SITE
OPUBLIC UTILITY
Connection Verified
PERMIT NUMBER
DATEINSTALLED
INSTALLER
OSeptic Tank or D Holding Tank
Size: If Tank is homemade
give dimensions:
SOILS RATING
TYPE OF TANK
MANUFACTURER _
TOTAL ABSORPTION. AREA
MATERIAL
4. DISTANCES
WELL T0:
Septic/Holding Tank
Absorption Area
Sewer Line
[Nearest Lot Line
Absorption Area to nearest Lot Line'
5. COMMENTS
D APPROVED FOR BEDROOMS
D CONDITIONAL APPROVAL (letter must accompany certificate)
D DISAPPROVED
DATE
BY
72-010 (Rev. 6/79)