HomeMy WebLinkAboutSAND LAKE #2 BLK 3 LT 8Sand Lake #2 Block 3 Lot 8 #011-134-41 Municipality of Anchorage Community Development Department Pepe 1 o1 3 Onsite Water & Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.orgionsita • (907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP121376 PID Number: 011-134-41 ❑ New ®Upgrade Name. MARILYN RABB ABSORPTION FIELD ® Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Addev : 8119 SEACLIFF STREET `ANCHORAGE, AK ❑ Other Phone: NM of rMWIftrmm efV Waft: (907) 522-7644 3 1.0 nPoleq.R 12 MAX R LEGAL DESCRIPTION De0l plookrMroom kll aft fweddpN °""'a me` SEE DWG. Ft 8.01 R SugdWon: Bb* tot Fa.fatf WowafpYWWtfa Gwei wen SAND LAKE #2 3 8 SEE DWG. 30 R R lo�lp: roe: _ a.,.iafat ranesrarw: orrae eawaener: 2.5 R R SEPARATION DISTANCES rarett.mw�...: 460 eO.R mwmofaendec 1 ow. e .rm e.,fem - R To�o Fleur A� Ult gL Holft RoYtlPMaet well '100'+ •lar+ 25+ TANK ® Septic ❑ S.T.E.P. ❑Holding ❑Other Surface WaW 1001+ lar+ - - ANCHORAGE TANK 1000 OW. Lot Line 64+• -a - - N/A MimY: M.rosaeanpre,ar: STEEL 2 LIFT STATION Foundation 51+ 101+ Mrtfm..m ostd4- Curtain Devin NONE KNOWN °0rrt"�QOT°� arc Remarks: OLDTANKWAS DECOMMISSIONED PER UPC. •ADEC WAIVER TO COMMUNITY WELL DATED 3112/2013. Pump Mese Model: heptaua pnbmef W. -WR#OSP121377 (INCLUDES 4' WAIVER TANK TO DRAINFIELD) PIPE MATERIAL SEE NOTE ON PAGE 3 OF 3 REGARDING OLD TRENCH LOCATION. Tankto House to tank D3034 drainfield D3034 Installer A+ HOME SERVICES Drainfield D3W CO/MT D3034 Inspector GEG, Ltd. BENCH MARK (Assumed elevation) 100.00 R Inspection 1orvm.a o..oeao,a Dates: Dates: 1St 7/28/14 2nd 7x29/14 3rd 7/3W14 4th BOTTOM OF SIDING NEAR BE CORNER OF HOUSE Community Development Department Approval ENMEEMBM 0060 Conditional approval: Date: o���•' �`5���0 Q .J f Gorne OQ @ � Jp�� E— 3 o`p� �AQG Approved: ( Date: S 18-/ �4°°Proreasio'o, �O°000��a OSP121376 AS -BUILT DRAWING 011134-4NUMBER: I - w Lu LL LL. J U Q w LOT 7, BLOCK 3; SAND LAKE #2 NOTE: ALL WELL RADII WERE STAKED/FLAGGED BY REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. A I B C FCO 48.2 7.8 19.5 ST1 62.4 17.8 29.9 ST2 23.4 33.8 DELI DRAWN BY: 25.2 35.4 DBL2 TYPE OF WORK: 26.0 36.4 FD LOT 18, BLOCK 3; 26.3 37.0 C01 20.6 38.8 MT1 d71.9 20.2 38.5 CO2 40.1 85.0MT2 40.0 84.9CO3 32.7 - 25.7MT3 28.4 31.9 'ROX. LOCATION OF OLD CRIB" NEW BE NEW LOT 9A, BLOCK 3; SAND LAKE #2 V I CIVIL & ENVIRONMENTAL ENGINEERS® 3 lE.WI WAQ EUI 101•ANGgRAGE, AM9B50]•F1iONE(807)3T81IB'FAJ((BO]J S3W348'NEB91]E:xwxgemuxnpneeM0.0m h I I'i I EXISTING Mn 3 BEDROOM DUPLEX r• NEW BE NEW LOT 9A, BLOCK 3; SAND LAKE #2 GRAINFIELD ' LOT 17, BLOCK 3; i I SAND LAKE #2 BENCH / 159 FEES WEA` I SAND LAKE #2 LOT 19, BLOCK 3; 1 I 1 NOTE: OLD DRAINFIELD IS ASSUMED LOCATION. PHYSICALLY i J"`� MEASURED 4 FEET FROM EDGE OF NEW SEPTIC TANK TO EDGE i I\ I DRAINROCK DURING INSTALLATION. LOCATION OF OLD TRENCH I I SOUTH OF TANK IS UNKNOWN. EFFLUENT FROM OLD TRENCH I I WAS NOT ENCOUNTERED WHEN INSTALLING NEW TRENCH. 100 FOOT WELL RADIUS ' I i 1 GARNESS ENGINEERING GROUP, L CIVIL & ENVIRONMENTAL ENGINEERS® 3 lE.WI WAQ EUI 101•ANGgRAGE, AM9B50]•F1iONE(807)3T81IB'FAJ((BO]J S3W348'NEB91]E:xwxgemuxnpneeM0.0m PREPARED FOR: PHONE NUMBER: PAGE NUMBER: r• 2 OF 3 LEGAL DESCRIPTION: I` .r: DRAWN BY: I I, , • TYPE OF WORK: DATE: �' LOT 18, BLOCK 3; 5/7/2015 SAND LAKE #2 •` I I GRAINFIELD ' LOT 17, BLOCK 3; i I SAND LAKE #2 BENCH / 159 FEES WEA` I SAND LAKE #2 LOT 19, BLOCK 3; 1 I 1 NOTE: OLD DRAINFIELD IS ASSUMED LOCATION. PHYSICALLY i J"`� MEASURED 4 FEET FROM EDGE OF NEW SEPTIC TANK TO EDGE i I\ I DRAINROCK DURING INSTALLATION. LOCATION OF OLD TRENCH I I SOUTH OF TANK IS UNKNOWN. EFFLUENT FROM OLD TRENCH I I WAS NOT ENCOUNTERED WHEN INSTALLING NEW TRENCH. 100 FOOT WELL RADIUS ' I i 1 GARNESS ENGINEERING GROUP, L CIVIL & ENVIRONMENTAL ENGINEERS® 3 lE.WI WAQ EUI 101•ANGgRAGE, AM9B50]•F1iONE(807)3T81IB'FAJ((BO]J S3W348'NEB91]E:xwxgemuxnpneeM0.0m PREPARED FOR: PHONE NUMBER: PAGE NUMBER: MARILYN RABB (907)522-7644 2 OF 3 LEGAL DESCRIPTION: DRAWN BY: SAND LAKE S/D #2; BLOCK 3, LOT 8A J.L.M. TYPE OF WORK: DATE: RECORD DRAWING OF SEPTIC SYSTEM UPGRADE 5/7/2015 PERMIT NUMBER PARCEL ID NUMBER: OSP121376 AS -BUILT D RAW I N G 011-134-41 TOPOFTANK AT INLET= 93.3 INVERTOFBUNG `NOTE: HAD CONTRACTOR EXPOSE OLD DRAINFIELD DURING INSTALLATION OF NEW SEPTIC TANK PHYSICALLY MEASURED 4 FOOT HORIZONTAL SEPARATION FROM EDGE OF TANK TO CLOSEST PART OF TRENCH. OBTAINED WAIVER FROM MOA DURING INSTALLATION BY CHANGE ORDER. (PER CONTRACTOR) L GRADE= 9TAW.66 ST2 NEW 1000 GALLON SEPTIC TANK INVERT OF BUNG AT OUTLET = 92.61 TANK GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL ENGINEERS PREPARED FOR PHONE NUMBER PAGE NUMBER MARILYN RABB 1 522-7644 1 3 OF 3 SAND LAKE SID #2; BLOCK 3, LOT 8A E OF WORK: PROFILE RECORD DRAWING J.L.M. 5(7/2015 DRAINFIELD %f On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP121376 Tax Code Number: 01113441000 Work Type: Septic Upgrade Permit Effective Dates: June 27, 2014 to June 27, 2015 Design Engineer. GARNESS ENGINEERING GROUP LTD Subdivision: SAND LAKE #2 Site Legal Address: SAND LAKE #2 BLK 3 LT 8 G:2224 OwneriAddress: RABB MARILYN K & DONALD F JR 200 W 34TH STREET ANCHORAGE AK 995033969 Site Mailing Address: 8119 SEACLIFF ST, APT B, Anchorage Lot Size in Sq Ft: 6750 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the Installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: PRIOR TO CONSTRUCTION: Additional percolation tests shall be completed such that the entire drainfietd is within 30 feet of a percolation test prior to construction. If the additional tests do not substantiate the permitted design, an approved change order shall be obtained prior to construction, i$ t PsG+i 11 V_iGik'r 0 t oe tAP.4 C$erbGi(.rr` �sv 'r2c�Ltt IS 4> rr*v+ ISO/. e P #'t"iL A & 0 Gtr 30 (?."IOS . aSt yr, t tr+ f S A Cge'r0$.. OR, etwov `r4 '-r)6jI(j _ JNY !�"io to <�*tii ;ems 00 A(-CoI&r' rsl tiy9%,A'Ah-7taN ssi h< LT PeAW1#46 a Receiv Issued On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP121376 Tax Code Number: 01113441000 7 Work Type: Septic Upgrade �Z �� 2 Permit Effective Dates: June 27, 2014 to June 27, 2015 - Design Engineer: GARNESS ENGINEERING GROUP LTD 7/zq/,, 33 Subdivision: SAND LAKE #2 Site Legal Address: SAND LAKE #2 BLK 3 LT 8 G:2224 Owner/Address: RABB MARILYN K & DONALD F JR 200 W 34TH STREET ANCHORAGE AK 995033969 Site Mailing Address: 8119 SEACLIFF ST, APT B, Anchorage Lot Size in Sq Ft: 6750 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: PRIOR TO CONSTRUCTION: Additional percolation tests shall be completed such that the entire drainfield is within 30 feet of a percolation test prior to construction. If the additional tests do not substantiate the permitted design, an approved change order shall be obtained prior to construction. Received Issued By r°c< �0 Col Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage Alaska 99519-6650 • (907) 343-7904 0 Fax (907) 343-7997 hftp://www.muni.ofg/Onsite Development Services Division On -Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: OSP121377 COSA#: Permit#:OSP121376 PID#: 011-134-41 Legal Description: Sand Lake #2. Block 3, Lot 8 Engineer: Garness Engineering Group Applicant: Marilyn Rabb Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 0 feet. Your request for a waiver of the required 16 feet horizontal separation between the absorption fields has been approved. The approved separation distance is 10.0 feet. Cod: y' _CeP�;�4,rk A-6 Aftcv z*.V "0 V, UEd. This waiver approval applies to the proposed a sorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ® The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of non -objection have been received from the owner(s) of the affected adjacent property. ❑ Adjacent properties are not affected by this waiver. ............................................................................... Waiver is Granted: x Waiver is not Granted: Date: / Approved b Name of Reviewer MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Fax: 907- 343-7997 On -Site Water & Wastewater Program Mayor Dan Sullivan On -Site Sewer/Well Permit Application For A Single Family Dwelling Parcel I.D. 011 - 13y-- 4\ Propertyowner(s) MARILYN RABB Day phone 522-7644 Mailing address 8119 SEACLIFF STREET *ANCHORAGE, AK Site address 8119 SEACLIFF STREET Legal description (Sub'd, Block & Lot) SAND LAKE #2; BLOCK 3, LOT 8 Legal description (Township, Section & Range) Lot Size Sq.Ft. Number of Bedrooms 3 APPLICATION IS FOR: ❑ (mall that apply) Absorption Field ❑ Septic Tank Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ APPLICATION IS AN: Initial ❑ Upgrade Renewal ❑ THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR: TYPE OF DEWELLING: Single Family (SF) ❑ (w/No ADU) Duplex (D) Multiple Dwellings ❑ (SF and/or D) DRAINFIELD TO DRAINFIELD. LOT LINE TO DRAINFIELD. Distance: 10' & 0' I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: s 3U Waiver Fees: 2100 — Date of Payment: l0 h` l l a C&2: Date of Payment: I O I I$ f o_ Receipt Number: 05,:S S G Receipt Number: O 3L S Permit No. 05f l q;� 131 llo Waiver No. O t)1a 1 311 (Rev. 01/11) 6)SpIII z1,?7f6 GARNESS ENGINEERING GROUP, Ltd -� - CIVIL&ENVIRONMENTAL ENGINEERS ---- - June 25, 2014 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650, Anchorage, Ak 99519-6650 (907)343-7904 Ref: Proposed Septic System Upgrade for Sand Lake #2; Lot 8, Block 3, To whom it may concern: The existing 3 bedroom Duplex is served by a class "C" well and a private septic system. The existing septic system is in a state of failure and needs to be upgraded. We are proposing to install a 1000 gallon septic tank and a deep trench type drainfield. A portion of the proposed drainfield is located on the neighboring property (Sand Lake #2; Block 3, Lot 9) which has dual ownership between the owners of Lot 8 & 10. The owners are in the process of subdividing Lot 9 down the middle to expand their lots (Lot 8 & 10). Because Lot 9 has not been subdivided to date, an ingress/egress easement has been provided. One test hole was excavated on the property. The drainfield will be designed around the 30 foot radius of this test hole. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which show the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications 3. SURFACE WATERS: There are no surface water concerns. 4. TOPOGRAPHY: As can be seen on the attached site plan, the average topography around the drainfield is less than 5% running west to east. In short, there are no slope concerns. 5. LOT LINE WAIVER: Due to site constraints, we are requesting a 0' lot line waiver from the south lot line to the proposed drainfield. There are no septic systems within 10 feet of the south lot line. 6. WELL WAIVERS FOR SUBJECT PROPERTY: Due to site constraints, the proposed septic system is located within 100 feet of a class "C" well (required distance must be 150 feet). Attached to this submittal is the granted waiver from ADEC (3/12/13) approving the installation of the septic system to within 94 feet of the class "C" well. We are proposing to put the new septic tank and drainfield 100 feet away from the subject well. 7. PROPOSED DRAINFIELD TO EXISTING DRAINFIELD: We are proposing to install 8 feet of effective for the proposed drainfield. The required separation distance for the proposed drainfield to any 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com Page 2 of 2 other drainfield would be 16 feet. Due to site constraints, we are requesting a 10' waiver from the proposed drainfield to the existing drainfield. Comments supporting the waiver request are listed below: • There is no other viable location that a drainfield can be located. • The two drainfields will not service the house at the same time. In short, only one drainfield will be active at a time. In short there is minimal risk associated with the grating of these waivers. We are unaware f any adverse impacts this installation would have on adjacent wells or septic systems. If you have arty cl ei stions, please contact us at 337-6179. Thank you for your assistance. P.E., M.S. 3701 East Tudor Road, Suite 101 *Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338.3246 * Website: www. garnessengineering.com LOT 6,BLO 3; ti� I LOT :oCK3; i I/ \ w 100' W Lij \ �� Al \ / I\� ---- 1 LL. LOT 9, BLOCK 3;/K, U \ \ Q LOT 10,13LOCK 31 / L -100' WELL RADIUS LOT 11 OCK ' LOTS 11 & 12 SERVED BY PRIVATE WELL ON LOT 12 I � \ LOT 12,.,WOCK 3; / LOT 19, BLOCK 3; I � I w L BLOCK 3Lli ; Q \ \ c BLOCK 3; \ LOT 16, BLOCK 3; LOT 'M, BLOCK 3; LOT 13, BLOCK 3; - / - - - --- - - - - 1 WEST 82ND AVENUE LOT 1, BLOCK 5; 1 LOT 24, BLOCK 5; GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS 3101 E. 1000F FOAM. 591E 101 • A HN E, M 89307 • PHONE (907)337 -Sin • FAX (807)1.19 -MM MEOSDE: vw.9ornwe,rypmxirpxon PREPARED FOR: PHONE NUMBER: PAGE NUMBER: MARILYN RABB 522-7644 1 OF 2 LEGAL DESCRIPTION: DRAWN BY: SAND LAKE #2; BLOCK 3, LOT 8 PNB TYPE OF WORK: DATE: SITE PLAN 8/22/2A- [Ke, /22/2: [Ke, ul=) NUMBER OF BEDROOMS: 3 GALLONS PER DAY (GPD): 450 PERCOLATION RATE/S: 5 PROPOSED APPLICATION RATE: 1 MINIMUM DRAINFIELD SO.FT.: 450 MAXIMUM DEPTH: 12 FEET WIDTH: 2.5 FEET LENGTH: 30 EFFECTIVE: 8 FEET ACTUAL SO.FT.: 480 LETTER THAT PERTAINS TO THIS DESIGN. TO OBTAIN A COPY OF THE LETTER CONTACT GEG. BY PROCEEDING FORWARD WITH THIS INSTALLATION, THE ENGINEER, WELL DRILLER, CONTRACTOR AND PROPERTY OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND CONDITIONS OUTLINED. _ NOTE: THE CONTRACTOR SHALL HAVE THE PROPOSED ' SOUTH LOT UNE, & ALL WELL RADII FLAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. THE WATER SERVICE LINE SHALL BE PROFESSIONALLY 1 LOCATED. 1 / \ 5 \ W \ I W 1 1 \ry cn l 'r U I W I _eco I LOT 19, BLOCK 3; LOT 6, BLOCK 3; SAND LAKE #2 SAND LAKE #2 / >< / / LOT 18, BLOCK 3; \ �I /i SAND LAKE #2 LOT 7, BLOCK 3; SAND LAKE #2 \ DECOMMISSION R NG SEPTIC TANK PER UP'F. EXISTING 3 NST L BEDROOM FCO EXI ING DUPLEX 0 T DRAT FIE i-5 LOT 17, BLOCK 3; 1-5-% 5 GALRON 3 SEPTIC ED 00 SAND LAKE #2 ��. Mf RELOCATED 5% ' I 11-57 11-5% 1-5% -cC LOT 9, BLOCK 3; SAND LAKE #2 / / LOT 10, BLOCK Z; SAND LAKE #2 _ 90' WELL RADIUS LOT 11, BLOCK 3;SAND LAKE #2 GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS 3701 E. T0009 RO!D, SHOE 101 • ,WOXORAOE. M 9050) • R E (907)537-81)9 • FM (907)338-3249 • 11E95OE: ,ry ga�im dn9.am PREPARED FOR: PHONE NUMBER: PAGE NUMBER: MARILYN RABB 522-7644 2 OF 2 LEGAL DESCRIPTION: DRAWN BY: SAND LAKE #2; BLOCK 3, LOT 8 PNB TYPE OF WORK: DATE' SEPTIC SYSTEM DESIGN UPGRADE 10/10/12 �—PR POSED LOT LINE SAND LAKE #2 LOT 16, BLOCK 3; \ I \ ® \ N SCACfi: LOT 14, BLOCK 3; 00004 kTH *.J. ar ess.79$3 aG GARNESS ENGINEERING GROUP, Ltd. z CONSULTANTS & GENERAL CONTRACTORS 11 E. %DOR ROAD, SURE 101 • ANCHORAGE, M. 99W7 • PHONE: (907)337-61n • FM: (90MW—n2 • W M' gomeawnginaeHi SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: sANU LAKL #2; CLUOK s, LUI a MARILY RABB DATI PERFORMED FOR: 6.00" — 2 3:30 30 (feet) ^^^ ORGANICS TEST HOLE #1 1 6.00" — _ 30 0" SOIL CLASSIFICATIONS 5 4:00 — 6.00" — 6 4:30 GW ORG 0" 6.00" LOAM GP ML — GM CL 4 GC OL oo•o o SW MH 0 0 0 0 5 • : SP CH SM i OH 6 SC 7- 8- 9- 10— SM 8910SM 11 12- 13- 14- 15- 16 213141516 n•• n••q• 17 SP 18 „.... DEPTH TO GROUNDWATER DATE DRY 9/5/12 DRY 9/13/12 6.00" — 2 3:30 30 SEE ATTACHED SITE PLAN DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 9/5/12 1 3:00 — 6.00" — 2 3:30 30 0" 6.00" 3 3:30 — 6.00" — 4 4:00 30 0" 6.00" 5 4:00 — 6.00" — 6 4:30 30 0" 6.00" 19� PERCOLATION RATE 5 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 6.0 FT. AND 7.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ® YES ❑ NO SOILS LOGGED BY: PIERCE BLEWETT PERCOLATION TEST PERFORMED BY: PIERCE BLEWETT COMMENTS: PERCOLATION RESULTS ARE WITHIN 1/16TH OF AN INCH PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFyRMEq IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: THE STATE 01A.LA.SKA March 12, 2013 GOVERNOR SEAN PARI;ELL Mr. Jeffery Gamess, P.E. Gaaress Engineering Group, Ltd. 3701 East Tudor Road, Suite 101 Anchorage, AK 99507 Re: Sand Lake S/D, Block 3, Lot 8 Class "C" Public Water System Water Source Separation Distance Waiver Request Dear Mr. Gamess: Department of Environmental Conservation DIVISION OF ENVIRONMENTAL HEALTH Drinking Water Program 555 Cordova Street Ahchorage, Alaska 99501 Main: 907269.7631 Fax: 907269.7650 thonws.brannon®aloska.gov File: Sand Lake S/D. #2, Block 3, Lot 8 ✓ PWSID: 216156 On November 15, 2012, this office received your request for a waiver of the State's minimum separation distance between a drinking water source and a potential source of contamination. The intent of this letter is to grant a waiver between the ddnidng water well located at Sand Labe Subdivision, Block 3, Lot 8 and the new septic tank and absorption field being proposed on lots 8 and 9. For the continued health and safety of the water system's users, it is strongly recommended that the system be routinely inspected and tested. While there is no ongoing state requirement for inspections, visual inspection of the well and surrounding area (within approximately 200 feet) will help identify potential risks to the system. There is also no requitement for ongoing drinking water sampling. Bet, periodic sampling for nitrate/nitrite and total coliform (recommended at least annually) will help identify drinking water issues that may otherwise go unnoticed. The well located at Sand Lake Subdivision #2 (SLSD2), Block 3, Lot 8 is classified as a Class "C" Public Drinking Water System. The system serves drinking water to SLSD2, Block 3, Lots (4, 5, 6, 7, & 8) and is identified by PWSID 216156. The location of this well fails to meet the 150 foot separation distance, prescribed by regulation, between a Class "C" Water System and a wastewater disposal system. According to submitted documents and ADEC files, the well is located 94 feet, at the nearest point, from the proposed septic tank and absorption field The well is also subject to the following encroachments in the table below: 130312 Sand Lake SD, Block 3, Lot 8_216lX-WA don Page 1 of 3 Mr. Jeffery Gayness, P.E. March 12, 2013 The separation distance encroachments listed above have previously requested and received DEC waivers. The fully cased well was installed October 3, 1982 to a depth of 397 feet The well penetrates sand, sandy grave, and sandy day from 8 to 243 feet below ground surface (bgs). From 243 to 393 feet bgs, the well passes through confining layers of wet day and clay/gravel. Small gravel and water was found from 393 to 397 feet bgs. Static water level in the well was recorded at 140 feet bgs and yielded 60+ gallons per minute The following items were taken into consideration as part of this waiver 1. The ground surface at the well slopes easterly toward the septic tank and absorption field; 2. The source water was sampled and tested free of nittate/nitrite, 13 rof and total coliform on November 7, 2012; and 3. The well accesses a presumed deep confined/semi-confined source water. Based on evaluation of the available information, the potential for contamination due to the leaser separation distance between the public well and the proposed septic tank and absorption field appears to be of moderate significance due to the high density of septic systems in the immediate arem however, examination of the system's water sampling results reveals a history of acceptable nittate/nitrite and total colifomm levels and suggests that the well is not highly influenced by septic ex -filtration. This demonstrates that the lesser separation distance does not appear to immediately threaten public health. Therefore a separation distance waiver between the well and the proposed septic tank and absorption field is granted in accordance with the State's Drinking Water Regulations, 18 AAC 80. Any changes, constructed or natural, that affect the conditions to which these waivers were granted will void these waivers. This approval does not imply the granting of additional authorizations, nor obligate any federal, state, or local regulatory body to grant required authorizations. This is not an approval of omissions or oversights by this office or noncompliance with any applicable regulation. The Department's registration of this Class C system and separation distance waiver does not guarantee correctness of the functional design or waive the owner's responsibility for continued compliance with State regulations. AMA Process Any person who disagrees with this decision may request an adjudicatory heating in accordance with 18 AAC 15.195- 18 AAC 15.340 or an informal review by the Division Director in accordance with 1S AAC 15.185. Informal review requests must be delivered to the Acting Division Director, Elaine Busse Floyd, 555 Cordova St, Anchorage, Alaska 99501, within 15 days of receipt of this decision. Adjudicatory hearing 130312_Sand Lake SD, Block 3, Lot 8_216156 WA.docx Page 2 of 3 Table L Separation Distance Encroachments Potential Source of Contamination Location to Lot Distance ft Septic absorption field B3, L6 134 Septic tank & absorption field B3 L7 102 Septic tank & absorption field B3 13 111 Septic tank & absorption field B3, L10 120 Septic absorption field B4 L17 137 Septic absorption field B4 L17 143 5 tic tank & absorption field $45 100 Septic tank & absorption field B4, Ll6 130 The separation distance encroachments listed above have previously requested and received DEC waivers. The fully cased well was installed October 3, 1982 to a depth of 397 feet The well penetrates sand, sandy grave, and sandy day from 8 to 243 feet below ground surface (bgs). From 243 to 393 feet bgs, the well passes through confining layers of wet day and clay/gravel. Small gravel and water was found from 393 to 397 feet bgs. Static water level in the well was recorded at 140 feet bgs and yielded 60+ gallons per minute The following items were taken into consideration as part of this waiver 1. The ground surface at the well slopes easterly toward the septic tank and absorption field; 2. The source water was sampled and tested free of nittate/nitrite, 13 rof and total coliform on November 7, 2012; and 3. The well accesses a presumed deep confined/semi-confined source water. Based on evaluation of the available information, the potential for contamination due to the leaser separation distance between the public well and the proposed septic tank and absorption field appears to be of moderate significance due to the high density of septic systems in the immediate arem however, examination of the system's water sampling results reveals a history of acceptable nittate/nitrite and total colifomm levels and suggests that the well is not highly influenced by septic ex -filtration. This demonstrates that the lesser separation distance does not appear to immediately threaten public health. Therefore a separation distance waiver between the well and the proposed septic tank and absorption field is granted in accordance with the State's Drinking Water Regulations, 18 AAC 80. Any changes, constructed or natural, that affect the conditions to which these waivers were granted will void these waivers. This approval does not imply the granting of additional authorizations, nor obligate any federal, state, or local regulatory body to grant required authorizations. This is not an approval of omissions or oversights by this office or noncompliance with any applicable regulation. The Department's registration of this Class C system and separation distance waiver does not guarantee correctness of the functional design or waive the owner's responsibility for continued compliance with State regulations. AMA Process Any person who disagrees with this decision may request an adjudicatory heating in accordance with 18 AAC 15.195- 18 AAC 15.340 or an informal review by the Division Director in accordance with 1S AAC 15.185. Informal review requests must be delivered to the Acting Division Director, Elaine Busse Floyd, 555 Cordova St, Anchorage, Alaska 99501, within 15 days of receipt of this decision. Adjudicatory hearing 130312_Sand Lake SD, Block 3, Lot 8_216156 WA.docx Page 2 of 3 Mr. Jeffery Garness, P.E. Match 12, 2013 requests must be delivered to the Commissioner of the Department of Environmental Conservation, La=y Hartig, 410 Willoughby Avenue, Suite 303, Juneau, Alaska 99801, within 30 days of this decision. If a hearing is not requested within 30 days, the right to appeal is waived. More information on the Department's administrative appeals process can be found at the following website: If you have any questions regarding this plan review please do not hesitate to contact me. Simcetely, y �• T.W. Brannan, E.I.T. Engineering Assistant I CC: Pierce Blewett Gamess Engineering, Ltd. pierce@gz=ssen&ecring.com Patrick & Paula Witherell 8041 Seacliff St Unit B Anchorage, AK 99502 Pamela Finnesand 8047 Sescliff St Anchorage, AK 99502 Michael & Blanca Burford 8055 SeacliffSt. Anchorage, AK 99502 Ranko & Marijana Ivanovic 8101 Seacliff St Anchorage, AK 99502 Donald & Marilyn Rabb 200 W. 34th St Anchorage, AK 99503 130312 Sand Lake SD, Block 3, Lot 8 216156_WA.doca Page 3 of 3 A 2014-024170-0 s Recording District 301 Anchorage C�l/ J K A 06/23/2014 01:27 PM Page 1 of 5 INGRESS AND EGRESS EASEMENT AND MAINTENANCE AGREEMENT THE STATE OF ALASKA MUNICIPALITY OF ANCHORAGE This Agreement is entered to be effective May 18, 2014 by and between Robin Connelly, ("GRANTOR" herein) and Marilyn Rabb, ("GRANTEE" herein). WHEREAS, GRANTOR and GRANTEE are co-owners of property described as: Sand Lake Subdivision #2 BLK 3 LT 9 WHEREAS, GRANTOR and GRANTEE are desirous of creating and maintaining an area for easement purposes, under certain terms and conditions (referred to herein as "Easement") being more particularly described and located as: For purposes of installing and maintaining a new septic system and leach field on the north half of the lot (Blk 3, lot 9, Sandlake #2, Subdivision) for the benefit of the property at Sandlake Subdivision #2 Blk 3, lot 8, otherwise known as 8119 Seacliff street, Anchorage recording district. WHEREAS, the GRANTOR and GRANTEE wish to reduce to writing such terms, conditions, and agreements pertaining to the Easement; I NOW THEREFORE, for a valuable consideration, paid by GRANTEE, receipt of which is hereby acknowledged, has and by these presents does grant, bargain, sell and convey unto the Grantee an easement as hereinafter described, to run with the land upon a certain parcel of land co -owned by the Grantor, ("Robin Connelly") and Grantee, ("Marilyn Rabb"), the above premises, GRANTOR and GRANTEE hereby agree as follows: 1. GRANTOR has GRANTED, SOLD AND CONVEYED, and by these presents does hereby GRANT, SELL and CONVEY unto GRANTEE, a perpetual, free, continuous and uninterrupted use, liberty, privilege and easement to use and enjoy the above described Easement. 2. Neither GRANTOR nor GRANTEE shall erect any improvements or other facilities, except related to septic systems and drainage; upon the Easement which may impair the flow of traffic over and across same. GRANTOR hereby grants to GRANTEE the right to permit the GRANTEE, GRANTEE'S invitees, guests, and others of the general public coming on the premises to utilize the Easement, it being the intention of the parties hereto that such persons shall have free access to, upon, and over the Easement for ingress and egress purposes. 4. GRANTEE will maintain the Easement until such time (if any) in the future when the Easement is released by written instrument, signed and acknowledged by the then owner(s) of GRANTEE'S property; and any mortgagee then holding a loan secured by GRANTEE'S property. This Easement shall be ONLY for the limited purpose of access, ingress, egress and maintenance to and from GRANTEE'S property. Said Easement shall bind and inure to the respective benefit of GRANTOR and GRANTEE. As used herein the terms GRANTOR and GRANTEE shall include the present and future owner or owners and mortgagees, their heirs, personal representatives, successors and assigns of GRANTOR'S property and GRANTEE'S property, respectively. INGRESS AND EGRESS FAMMrr AND AMINTINAME AGPJME T I�II�IIININININIIIII�iNIINilllllNINNI)NNNIININ Page 2 of 5 2014-024170-0 8. This is an easement, not a license. The Easement and right-of-way granted hereby is for the benefit of the GRANTEE'S property and shall be appurtenant to and run with the GRANTEE'S property. TO HAVE AND TO HOLD the above described Easement forever for the uses, benefits, purposes and burdens herein set forth, the GRANTOR does hereby bind themselves, their heirs, personal representatives, successors and assigns to Warrant and Forever Defend all and singular the said Easement and right-of-way against every person whomsoever lawfully claiming or to claim the same or any part thereof. GRANTOR and GRANTEE have duly executed this Ingress and Egress Easement and Maintenance A reement effective as of the n day of -),.I le- 20_L�_. n V (Grantor) 9 (Grantee) �A (Grantor (Grantee) STATE OF ALASKA § MUNICIPALITY OF ANCHORAGE The undersigned Robin Connelly, being the co-owner and co -holder of an existing Deed of Trust, does hereby consent to the grant of said Easement said and to the recording of same. Executed this 1-1"' day of jx � �, _,20 ! j . INGRESSANDEGRMEASEMEW AND MAINTENANCEAGREEMENT L!!!n NN'NN�IN PROPERTY CO -OWNER'S: INDIVIDUAL ACKNOWLEDGEMENT STATE, OF ALASKA MUNICIPALITY OF ANCHORAGE This instrument was acknowledged before me on J-tii- 17, W!3 by &6110 P +h Canno 11U. '� ,AWS "sit s c�5 ,..... iy 'h ,=Q� ; • PRY �'it Notary Public - State of Alaska Primed Name of Notary: Cr,.'fNk -A r;> I 3� '.LATE OF.•• My Commission Expires: L 0 AND MAMWANCEAGREENUVT Li!n NNNN[Nlr PROPERTY CO -OWNER'S: INDIVIDUAL ACKNOWLEDGEMENT STATE OF ALASKA § MUNICIPALITY OF ANCHORAGE This instrument was acknowledged before me on .lu-ig /%, by Ar,Li 4u n�u 4ebb UZP ARY i PUOVe 1. IT T p, 4 ° Notary Public - State of Alaska Printed Name of Notary: My Commission Expires: AFTER RECORDING, RETURN TO: INGRESS AND EGRESS EASEMENT cmn NNN;NNI�1� MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES Environmental Health Division 825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Name /� n DISTANCES A FC • TO SEPTIC ABSORPTION Address // FROM TANK FIELD WELL () �lLftm^a e 2`11`/ WELL 101,6 Phones Permit No. No. of Bedrooms Ste (`/ q /Q� LEGAL DESCRIPTION LOT LINE 201L / Lot Block Subdivision ,)fTo<3 1 rrd !z 11z FOUNDATION /,7,;- Township, wnship, Range, Section _ 1a N J'>�/a AS -BUILT DIAGRAM (Show location of well, septic system, property lines, foundation, driveway, water bodies, etc.) TANKS JI SEPTIC I Material ■❑ TYPE OF SYSTEM ❑ CH ❑ BED ❑ W. DRAIN ❑ OTHER Depth to pipe bottom Total depth from original gratle original grade FT FT Fill added above original grade Gravel depth beneat e FT FT FT Total absorption area Distance between lines SO FT AA Number of r Soil rating Pipe material n SQ FT sip -TS- Installer Jr P y/ Date Installed / Sz r� u tee. 4: 111719-7 F", 1167,2,4 . WELLS /S ❑ PRIVATE 0 OTHER (Identifv) Act I Classification (A,B,C) Total Depth Cased to A ,�1.7 a FT a / Installer Date Installed: REMARKS: ��„� /hPove �0 6lJn J✓/ Gats �z;<c 14 !k C /�� t ver a`l f Lrr /� iyO Se�a7/ic ��t7�r A Scale: Inspections Performed by: //7/ JnI�/ JJ?S LY7JCai HPCO J :✓CW lh JYe�1. [ �VIQ� S Date: 0,1 +v��e1 ¢ovf�e�. CO�J�d alb a !cu 3;017( ?j/7/gam Over- C- r to S' lle ,. See `i` /Jt s aC60', . I- /' certify that this inspection was performed according to all Municipal and State guidelines in effect on this date: . Date: 72-013 (3/85) 15 e ENGINEER'S SEAL I 'S"IrkFE O F ALASKA BILL SHEFFIELD, GOVERNOR DEPT. OF ENVIRONMENTAL CONSERVATION ANCHORAGE/WESTERN DISTRICT OFFICE 437 "E" STREET, SUITE 303 ANCHORAGE, ALASKA 99501 June 25, 1985 Alaska Environmental Control Services 1200 West 33rd Avenue Suite B Anchorage, Alaska 99503 274-2533 �1 10 SUBJECT: Horizontal Separation Waiver Between Welland Septic Tank, Lot 8, Block 3, Lot 10, Block 3, Sand Lake # 2, Anchorage Alaska - 8521 -WA -190 Dear Sir: The Department has reviewed the subject waiver request and hereby waives the horizontal separation between the well and septic tank to 120 feet and well to absorption field to 137 feet on the subject properties. Sincerely, eve pg, P.E District Enginee fF SE/dd 72-013 (Rev. 3/78) MUNICIPALITY OF ANCHORAGE ® DEPARTMENT OF HEALTH Fat ENVIRONMENTAL. PROTECTION ENVIRONMENTAL ENGINEERING DIVISION e 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME IMAILAG PHONE _EW ❑ UPGRADE A DRESS t 6 LEGAL DESCRIPTION LOCATION NO.OFBEDROOMS DISTANCE TO: Well _ Absorption area �' < Dwelling l�' PER O. �� UY � ,_5 wF Manufacture I�lat�ati�1j No. of compartments -ae.a y Liq. cagaci ty i gallons: IF HOMEMADE: Inside length Widthr Liquid depth Y DISTANCE TO: Well Dwelling PERMIT NO. J L7z 02 FQ- Manufacturer - Material Liquid capacity in gallons W = DISTANCE TO: Wel . , \ A} Foundation f Nearest lot line 7 C PER O. W u U Z w No. of line Len th a a lige g L Total len o links � ( Trench wi / Cly inches Distance t eek lines �f lip G f p Top of the to finish grade ! Material beneath tile ��-` Total eff ctive absorption area `� inches E7_2— W Length j, Width Depth / e ? PERM I � C7 i C� 6�p( F t�! wf- a ype oc�ib Crib diameter Crib depth } Total effective abspt n area LU DISTANCE TO:"C Well - Building foynda�n LL Nearest lot line f , J Class Depth Driller Distance to lot line PERMIT NO. J W Z: DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MATEF31ALS l SOIL TEST RATING j. �iJ�T Ca A INSTALLER REMARKS a� j ti APPROVED DATE LEGAL 72-013 (Rev. 3/78) 3 3 3 3 3 3 3 3 3 3 US:gyp w: o: o :w cn ; CO o f cn : w o y -M y y O O O O O O O O O O -4: Co O O W :01 00 O : CA ?0c) N tn- io � ' 01 R.: i :P� :- �i c�c0�9 Eck N i C+ C+ (D •� _ Oq C m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 F ' vrt p� 0v2: .Z m ryn v o O 00 N li HPPLICHNT PHUL F. -I FEE '' DEPHRTMENT HEHLTH AND ENVI�ONMENTHL FORTH BY THE MUNICIPHLITY ROTECTION ' 825 'L' STREET, HNCHORHGE. HK 99501 � ^+ ]� I UNDERSTHND THAT 264�4720 SYSTEM MHY REQUIRE ENLHRGEMENT IF THE K R,, ghl j, 9—H 6 44 ­- TEX 1 V FIE. EEEi 0-1 Eon�� PERMIT NO ( 820701 ) \ � ED- ERGEON \ , 2707 KLHMHTH 9950] Q LESHL 8]L8 WAND LAKE #2 FEET � TYPE OF SOIL H8SORPTION SYSTEM IS: TRENCH � ( i (� ` MHXIMUM NUMBER OF BEDROOMS z `� SOILRHTING (SQ FT/BR)� 206;u om `\ ' THE REQUIRED SIZE OF THE SOIL HBSORPTION SySTEM IS� /— Ell FEE Fol W 1-1 ��9? V FEE 1.. 120 F:_�' 1y " O-Ak-­ _ THE LENGTH DINENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRHINFI THE DEPTH OF H TRENCH QR PIT IS THE DISTHNCE BETWEENTHE SURFHCE OF Tri,.�_L"w« ' GROUND HND THE BOTTOM OF THE EXCHYHTION (IN FEET) ~ '�/� � THERE IS NO SET WIDTH FOR TRENCHES, THE GRHVEL DEPTH IS THE MINIMUM DEPTH GF BETWEEN THE P AND THE BOTTOM OF THE EXCHVHTION (IN FEET:',.' -� PERMIT MAP L.I(DAN T HHS THE RESPONSIBILITY TO INFORM THIS DEPHRTME ITT DURING THE IPUT ALAR TION INSPECTIONS OF ANY WELLS ADJHCENT TO THIS PROPERTY HND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE, ���-1 20 Do �FIE (11' Y 1 W Pro _F.-, 9- i]F_�,EEE �����1 IP,_" F E> _~~ BHCKFILLING OF FAYSYSTEM WITHOUT FINAL INSPECT7ON HND HPPROYHL BY THIS DEPHRTMEMT WILL BE SUBJECT TO PROSECUTIO�� MINIMUM DISTHNCE BETWEEN H WELL HND HNY ON�SITE SEWHGE DISPOSHL SYSTEM IS 100 FEET FOR H^PRIVHTE WELL OR IL50 TO 200 FEET FROM H PUBLICWELL DEPENDING UPON THE TYPE OF PUBLIC WELL HINIMUM DISTHNCE FROM H PRIVATE WELL TO 8 PRIVHTE SEWER LINE IS 25 FEET HND TO H COMMUNITY SENER LINE IS 75 FEET, NELL LOGS HRE REQUIRED HAID MUST BE RETURNED TO THE]0 DHYS OF THE NELL COMPLETION. OTHER REQUIREMENTS MHY HPPLY. SPECIFICHTIONS HND CONSTRUCTION DIHGRHMS HRE HVHILHBLE TO PF':OPER INSTHLLHTIO� �MASIM I _T- �:_ : FEE: W !J EFEE-EC: EEE FEFE ��� ���� I CERTIFY THHT HM FAMILIAR WITH THE REQUIREMENTS FOR OP&SITE SEWERS HND WELLS HS SET FORTH BY THE MUNICIPHLITY OF HNCHOR�GE 2: I WILL INSTHLL THE SYSTEM IN HCCORDHNCE WITH THE CODES. ]� I UNDERSTHND THAT THE ONNSITE SEWER SYSTEM MHY REQUIRE ENLHRGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE 1-1-4HN ] BEDROOMS � U HPPLICHNT P; i:B��GERON � ` ISSUED BY~�,��.~_ l9 SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION TEST 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG — PERCOLATION TEST PERFORMED FOR: Ob b -a! DATE PERFORMED: LEGAL DESCRIPTION: 1:5 �4iFi� I�k� i Block 8 F LLAA // \\ SLOPE SITE PLAN COMM PERFORMED BY: 72-008 (6/79) CSL)—�SdtI P1041c' /va J:j'/d P. �L I 9rove) r ��crx9 a WAS GROUND WATER —` S ENCOUNTERED? OL P IF YES, AT WHAT E DEPTH? "/ :r Y,l� obr .a. L"1U rN L. r1Z1. Reading Date Gross Time Net Time Depth to Water Net Drop +H�F� 7<1 rf:zs:jsl: 1.67 1.7-5 ,r� fi 1 I: Sz :?C) 7,:U✓ ;v3 10 zi + 1-} LC) I Z 1 Q3 ::30 �} i .9 � 13:.30 10 1 - U t�� t 147,0 r2` f T 1�4 PERCOLATION RATE 1 (minutes/inch) / -TEST R N BETWEEN Q'5 FT AND FT CERTIFIED BY: DATE: ' Z < < �8 14-3 CONSTRUCTION AND OPERATION CERTIFICATE :=:. �gL�ggjEA1 DEPARTMENT OF ENVIRONMENTAL CONSERVATION . PUBLIC WATER SYSTEM APPROVAL TO CONSTRUCT Plans for the construction of water system located in Alaska, submitted in accordance with 18 AAC 80.100 Q' ; J Y have been reviewed and are by :9 approved. ❑ conditionally approved (see attached conditions). By wr "e If construction has not started within two years of the approval. date, this certificate is void and;revv plans and specifications must be submitted for review and approval before construction. •���� „,, APPROVED CHANGE ORDERS_ Change (contract order no. or dewrlptlw reference) Approved !r by Date C--_ The "APPROVAL TO OPERATE" section must be completed before any water is made available to the public. APPROVAL TOOPERATE The constructicyioi;the U C K S�iVO L A �publie (date). The system is hereby water system'vtras completed on granted interim approval to operate for 90 days following the cpmpletlon date. OATS eV TITLE As -built plans submitted during the interim approval period, or an inspection by the Department confirmed the system was constructed according to the approved plans. The system is hereby granted finagapproval to operate, TITLE DATE EANIOWpw 831 ' F j4 l Joe P. Josephson JOE p. J03EpHSON i ASSOCIATESits I" 415 1016 Nest Sixthk ' Anchorago 99 O1 i OVm RS' AGRLE M FOR JORPR )FIT MA'i'BR SYSTEM 1[ t TRIS AGREEMMt by and between PAUL BSRGERON, P hereinafter called "First Party"; OLIVER TMEX and mAux Tow=, hereinafter called *Second Party"; 'PAUL ROSELM, hereinafter called "This Party"; and ROE ROSELAND, hereinafter called "Fourth Party" N I T N E S 8 S T S s J 1. Properties Affected. The parcels or properties affected by this agr eement are Lots Six (6) (7) of Block Three (3) of SAND LMM SUBDIVISION and Seven NMgR TOO, according to Plat_• in the Anchorage Recording District, Third Judicial District. Alatka, �I which lots are owned by Second Party; Lot Five (S) of b SUBDIVISION NUMBER TWO Block Three (3) of SAW LAM aforesaid, which lot ii owned by Fourth Party; Lot your (3) of SAND LADE SUBDIVISION NUMBER � (4) of Block Three T1ip aforesaid, which lot is owned by Third Partys and Lot Eight (E) of Block Three (3) of SAND LA" SUBDIVISION �f yuM8R M aforesaid, which lot is owned by First Parti. 1ration 2� Nonprofit Cor o reed to. Each of the r t pasties has agreed to the incorporation, under the laws of Alaska, of a nonprofit corporation to be known as LAEL ZZ(Jr'�R '1M MA'iWWRI[8, IPC. SAM , The corporation will Provide* !I 3. Co rate Pu was. nonprofit basis, water service originating from a water on a underground within Lot Eight (6), Block Three (3). source oresaid, t SUBIDrnsioN PSR TwO af'.0 of the r3 SAND LAKE It is intended that each ProrpertY a properties described above. . their respective rand sham, her ar►d owner of the said propertiesr ��,,r� shall furnish to the corporation asa3gns. successors, heirs and reaoGess for of providing asonabiB �." easements for the P T� maintenance, operation and repair of the K Aa. rMO contemplated system for the delivery of water service. Each residence is to be assessed or charged equally, on a monthly basis, for the prorated cost of water services equal to the electrical and maintenance cost required for the conveyance and transmittal of water to the lots. 4. Purpose of this Agreement. The parties desire, by the filing or recordation hereof, to give public notice that a certificate of incorporation for SAND %AXZ NUIOMR TWO WATE1tiiOMM, IN., a nonprofit corporation, has been requested of the Alaska Department of Camperce and Economic Development) that the corporation shall have perpetual duration for the purposes set forth above= that the affected and described properties will be charged for residential water service on an equal basis, to defray electrical and maintenance costs of the water sytem serving such residences= and that the owner of Lot Eight (d! , Block Three (3) , of BARD LAKE SUMMSYCN NUMBER TM has agreed tient water frost an underground water source on the said property shall be furnished to the; system for utilization withiA the residences constructed or to be constructed on the lots described above. DATED at Anchorage, Alaska this OUR, day of December* 1982. aul Be -Mere, First Party MK 3 - STATE or ALASIM } ss. THIRD JUDICIAL DISTRICT } r':. BEFO1tE i�� a 3totary Public it and for R Alaska, this day personally appeared M!!eelNlalt', TMSZ MM •OVSgE, PAUL+ ROSELAND, and RQN 1 i` oLIVISR ROSSI.AND, and they and each of them did acknowledge himself and not for each th"f ! before me* each for rof that the for Ownera' Agreement for None voluntarily, Nater System was executed freely and and purposes therein described, and ti for the uses with knoMledge Of its ooatents. DATED at Anchorage. Alaska this day of December, 1982. Co ss o exp res n 'e irk F 4, D STATE 01P ALASKA } ) se. •:TBTW JUDICIAL, DISTRICT ? BErOM ME' a Notary Public in and for the appeared I personally State of Alaska* this id rbe - PAUL BERGERM and he did 1 A reemnt for oNonp �O f it that the foregoing Owners g and voluntarily, system Was e�Yposes in described, and water thereuted for the uses and PU {� with Knowledge of its contents. 'yam DATED96 *t Anchorage, Alaska this �C day of 086emb ' - -41 0009 ri 'aEc,.:;;�,pk"E� C�ission �P -.`=-� pot +MG1i0RAGE REC. DISTRICT ;� `-,.'• _"" . '» J t%QlriE5YEb 81fA-5:, r.7DRESS Municipality of Anchorage a On -Site Water & Wastewater Program (907)343-7904 Su It4AY � Gretchen Stullei CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I. D. 011-134-41 Expiration Date: O �J 1. GENERAL INFORMATION Complete legal description SAND LAKE S/D t/2; BLOCK 3, LOT 8 Location (site address) 8119 SEACLIFF STREET, ANCHORAGE, AK 99502 Current Property owner(s) MARILYN AND DONALD RABB Day phone 522-7644 Mailing address Real Estate Agent 200 W. 34TH STREET, ANCHORAGE, AK 99503-3969 JENNIFER ZIMMERMAN Day phone 2. TYPE OF DWELLING: ❑ Single Family (w/wo ADU) Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 440-2175 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class O Well 0 Community On-site ❑ Public Water System ❑ Public Sewer ❑ WaiverlVadance request for. Received by: 1/6 Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ rho 80 5U Waiver Fee $ Date of Payment JF ! i� �(rJ Date of Payment Receipt Number Q� �J?�oC') Receipt Number COSA # 050 5/01114 Waiver # Distance: 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. l further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK, 99507 Engineer's Printed Name Engineer's Comments: JEFFREY A. GARNESS, P.E. In conducting this evaluation, GEG provided an engineering evaluation of the "N and/or septic system in accordance with the guidelines andiegulations established by the Munaipalty of Anchorage and indusby practices. The mportedresults describe the condition of the sysfemus on the deteis of the evaluation. Separafron distances were measured to readily klantflabk features. Hadden defects cr encroachments may ezistthat were notldentfi'ed during the evaluation. The operational hie ofaff wells and septic systems depend on a variety of variables including, but not limbed to, soil wraffhans, groundwaterkvels /that may guctuate during the year), qua* of construction (materials and workmanship), and the water usage of Me family ugNzing the syskrNs. These conditions can vary, and are outside the control of GEG. Sagsfadorylastresufts do not guarantee brture pedamance of the cysterNs,; therefore, GEG makes no warrantylexpress a implied) regarding the future pedmmance of the well aseptic system GEG makes no representabon whether an alternative wetur septa system can be installed on thepmperfy in the event etheroffhe current systems fail The content of this report is for the sok benard of the permoarty who retained GEG. Reliance upon the information providedhi this report by any ofher person orparty, including but not Ibnifed to subsequentpropertypurchasers, is not authorized. In short, GEG dkavows any legal duty to anyone other than the pownipady who paid krthisreporf. 6. DSD SIGNATURE __LC System #1 Approved for I? bedrooms. System #2 Approved for Disapproved. Conditional approval for M bedrooms. Phone 337-6179 Date 13 hS bedrooms, with the following stipulations: 071137x... OFESSt :i OF ON-SITE WATER AND WASTEWATER Original Certificate Date: [ 9 — /.J' The 9trnlclpaK &'A' nch a Develop,emt Services Division (DSD) issues Certilicates of On -Site Systems Approval (COSA) based only upon the represenatatins given in paragraph 5. by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. - 7. ATTCHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory (R. 10/19119) v Nitrate Advisory . Arsenic Advisory Other If more than 1 septic system Is on the lot: COSA Checklist # _of_ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: SAND LAKE S/D #2; BLOCK 3, LOT 8 Parcel ID: 011-134-41 A. WELL DATA Well type CLASS °c' If A, 8, or C provide PWSID# 216156 Well Log (Y/N) - Date completed 10/311982 Sanitary seal (Y/N)= Wires properly protected (Y/N) Total depth - ft. Cased to ft. Casing height (above ground) in. FROM WELL LOG Date of test Static water level ft. Well production g.p.m. WATER SAMPLE RESULTS: AT INSPECTION ft. g.p.m. Coliform NEG colonies/100 ml. Nitrate ND mg./L. Collected by: GEG, Ltd. Arsenic: 46.3 ug./L. Date of sample: 4/2212015 B. SEPTIC/HOLDING TANK DATA Tank Type/Material STEEL Date installed 7/28-30/2014 Tank size 1000 gal. Number of Compartments 2 Cleanouts (YIN) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) NIA Date of pumping NEW Pumper LESS THAN 1 YEAR C. ABSORPTION FIELD DATA BELOW FINAL GRADE Date installed 7128-30/2014 Soil rating (.p.d. r Obdrm) 1_0 System type TRENCH Length 30 ft. Width 2.5 ft. Gravel below pipe 8.01 ft. Total depth "12.5 ft. Eff absorption area 480 ftz Monitoring tube YES Depression over field NO Date of adequacy test NEW Results (Pass/Fail) For 3 bedrooms Fluid depth in absorption field before test = in. Water added =gal. New depth =in. Elapsed Time: = min. Final fluid depth = in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date - D. LIFT STATION Data installed "Pump on" level at in. E. SEPARATION DISTANCES Size in gallons Manhole/Access "Pump off" level at r alarm level at in. Cycles tested Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: CLASS *C" WELL Septic tankilift station on lot *lar+ On adjacent lots *100'+ Absorption field on lot *100'+ On adjacent kits `1001+ Public sewer main WA Sewer Iseptic service line 25'+ Animal containment areas 50'+ Public sewer manhole/deanout NIA Holding tank WA Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC(HOLDING TANK ON LOT TO: Building foundation 5* Properly line 5'* Absorption field Water main 101+ Water service line 1o'+ Surface water 100'+ Wells on adjacent lots 100'+/'*lw+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line ***a Building foundation 10'+ Water main 101+ Water service line 111'+ Surface water 1001* Driveway, parking/vehide storage 10+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+/* lw+ F. COMMENTS *ADEC WAIVER TO COMMUNITY WELL DATED 3/12!2013 ( NUMEROUS ADEC 10t1' WAIVERS ON FILE **TO CLASS "C" WELL ON LOT 16. *"WAIVERS GRANTED WITH ISSUANCE OF PERMIT AND CHANGE ORDER. G. ENGINEER'S CERTIFICATION I cerW that I have determined through field inspections and review of Municipal records that the aborre systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date /'l t 3%115 (Rev. 10/12112) Municipality of Anchorage pf. Community Development Department Development Services Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Arsenic Advisory Certificate of On -Site Systems Approval # 151217 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block 3, Lot 8 of Sand Lake #2 Subdivision. This inspection revealed an arsenic concentration of 46.3 micrograms per liter (ug/L) for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Information on arsenic is available from the On -Site Water and Wastewater Program website (www.muni.or /og nsite) or at 343-7904. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. 30' Wood Steps T in . ,GravelI- Parking' Pad:'.;'. PCC Pads LOT 7 2—Level Wood N Frame Duplex PROPOSED LOT 8A M 0 N d Wood Shed m (No. Foundation) N 0 ® ocb o 0 ui n Clean Out (TYp•) LOT 18 LOT 17 30' 135.00' CID I ".gQ'r5'nn".n, I LOT 16 PROPOSED LOT 9A NOTE: 1. A Preliminary Plat for Sand Lake Subdivision Addition No. 2, Lots 8A and 9A, Block 3 is being submitted to the Municipality for recording. 2. Distances are measured to the wood trim. SCALE : 1 " = 20' 0' 10' 20' 40' I hereby certify that an accurate survey of the following described property: SAND LAKE SUBDIVISION ADDITION NO. 2 LOT 8A, BLOCK 3 was made on October 23 2014 and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Easements other than those shown on the record plat may not appear on this drawing. Anchorage Alaska, this 30th day of April 2015. MUNICIPALITY OF ANCHORAGE 'r' • '� Department of Health & Human Services y r DIVISION OF ENVIRONMENTAL SERVICES M}t _ 343-4744 CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING Parcel I.D. # 1011-122)4-411 HAA # "R29f_M'1 3 1. GENERAL INFORMATION (Must be completed prior to submittal) (a) Legal Description (include lot, block, subdivision, section, township, range) � 4r 93 S2" d040 4 # z 7/Z N )2 yew Sr a Location (address or directions) (b) Property owner 10fl Re -9 Telephone: (home) Business Mailing Address (c) Lending Institution Mailing Address Telephone (d) Real Estate Company and Agent JD e Qj `4z ,06-42.e,/ /Rsc P -p / ej- ?-k Address J 2 70 C 5 Art.t. t 5j;le /oa2 i 9j-o.f Telephone (e) Mail the HAA to the following address: (or check heregif hold for pickup.) List contact person and day phone number below: e4e-C S �.c 2 -,;V —57'J 3 2. TYPE OF RESIDENCE Single -Family Number of bedrooms 3. WATER SUPPLY Individual Well ❑ Community j8,( Public ❑ Note: If community well system, must have:written confirmation from the State Department of Environmental Conservation attesting to th legality and status." 4. SEWAGE DISPOSAL On-site Public ❑ Community ❑ Holding Tank ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legailty and status. 72-025 (Rev. 7/88) Page 1 of 2 Z }o Z abed MOBS (BOIL °a) SZO-ZL •)ljom s,jaaul6ua leuolssa}ojd ay; ul suoiss)wo jo sjojja jo} alglsuodsajlou sl a6ejoyouy;o Al! led lolunIN ayl'ponssl sl a;eol}l;jeo a ajo}aq elep azAleue jo suolloodsul lonpuoo;ou op SHHd;o seeAoldw3 •s;uewaalnbei a;els pus lejapa} uleljao }sl;es o;japjo ul suol;n;l;sul 6ulpual clay; pue savoy ;o sjoseyojnd o; �(saljnoo a se sly; saop SHHG ayl 'eMsely }o alelS ayl ul p9j84s16aj jaaul6ua leuolssa}ojd luepuedepul ue Aq anoge 9 ydej6ejed ul U0n16 suol;e;uasajdaj all uodn �Siuo paseq pa;Bol}ljao lenojddV Aj!joylnV ylleaH sanssl (SHHCI) saolnjaS uewnH pue y;leaH }o luawljedaO 96eaoyouy }o AllledlolunlN ay.L lenojddy leuol;lpu0010 swjal leuol;lpuo0 panojddesld ----- — panojddy ale(] Aq swoojpa �jo; panoaddy 1VAOaddV SHHO '9 4 L, ,- \051ssadoldk® � 4 4n ,. •op°.... o°ee Bf s •ar 'a(�$S taut u3 4 C en x.• oo•es••+ a0000em co•se 0000gMo(°� 6 ••tl••000 P ° Y D • °Atl' tybr°°••••o a 7 2rligio 2' o� 0 ssajppy auoydalei 5 -?--1 wall }o aweN •uol;oodsul sly; }o a;ep ay; uo;oa};a ul suol;eln6aj pue 'saoueulpjo 'sapoo 01e1S pue ledlolunvi lie yl!M aouelldwoo ul sl LuelsAs lesodslp ja;emalsenn jo/pue Aiddns jaleM ells-uo ay; 'uol;oadsul pue Vol;e6l}sanul �(w woj} pue sell} a6eaoyouy ;o L(;!led!o!unlN ay; w0j; poulelgo uol;ewjo;ul ay; uo paseq }ey; �(;ijan jayljn} 1 'ulajay pa;eolpul ajn;onj;s }o ad�(l pue swoojpaq }o jegwnu aq j enoiddy Alljo e n Voll es } `a;es sl wals�(s lesodslp jalumalseM jo/pue Alddns jalem alis-UO osepegl 9May axl a easlw�(y�a )ueosy siy; }o uol;e6l;sanul Aw;ey; �(}ljan I 'nnolaq umoys a;ep Vol;epllen ay;; y P ;; I q p ; ; NOIlVWa0dN1 ONV V1VO `HOUV3S 3lld `S-LS31 `SN01103dSNl JNIOIAOad Wald ONIa33NION3 'S MUNICIPALITY OF ANCHORAGE (MOA) • ti, OF ANcV�t7ft Authority Approval (HAA) td TAL SERVICE IST - FEBRUARY 19841 ENVII 343-4744 ,"'4 3 5320 /Cc #iIj 2 Legal Description: 2 /u s�o A. WELL DATA FCEIVE' Well Classification If A, B(�VD.E.C. Approved(N) Well Log Present (Y/N) Date Completed Yield Total Depth Cased to Depth of Grouting Static Water Level Pump Set At Casing Height Above Ground Sanitary Seal on Casing (Y/N) Electrical Wiring in Conduit (Y/N) Depression Around Wellhead (Y/N) SEPARATION DISTANCES FROM WELL: To Septic/Holding Tank on Lot ; On Adjoining Lots To Nearest Edge of Absorption Field on Lot ; On Adjoining Lots To Nearest Public Sewer Line To Nearest Public Sewer Cleanout/Manhole To Nearest Sewer Service Line on Lot Water Sample Collected by /_ /fie i d ; Date /0/?0/S 9 . Water Sample Test Results Se c-1 Comments B. SEPTIC/HOLDING TANK DATA /1-7- Y9 Date Installed $2 _ Size / 000 No. of Compartments Z Standpipes 6%N) Air-tight Caps &91N) Foundation Cleanout (�i I) Depression over Tank (Y/Ol Date Last Pumped9ZZ�/Ff r 1 saac r. Pumping/Maintenance Contact on File (Y/N) �/A ; for A-V Holding Tank High-Water Alarm (Y/N) -Temporary Holding Tank Permit (Y/N) SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK: To Water-Supply Well %D/.6 To Building Foundation 5'f/ To;Property LineZ-Z To Disposal Field /G f To Water;Main/Service line Z 0Y To Stream, Pond,Lake or Major Drainage Course /0 0 Comments 2'�.rk n.roved -/0!a!•ro' ... G/.ars e g"e// bves f r,N 9.)0 d house 5/7// 72-026 (Rev. 7/88) Front Page 1 of 2 C ABSORPTION FIELD DATA Soils Rating in Absorption Strata 706 Type of System Design Ce,d 4-7'r-excXi Date Installed y-Qa Length of Field 3S7"Fc�c% I9X�z'Cf ,4 �� Leng Width of Field Depth of Field Gravel Bed Thickness Square Feet of Absortion Area aeA4 yz-o 0,1L jLA Statndpipes Present cg;1) Depression over Field (Y6 Results of Last Adequacy Test Date of Last Adequacy Test S U SEPARATION DISTANCE FROM ABSORPTION FIELD: To Water -Supply Well 1 24 To Property Line To Building Foundation er16 /T/ %te»`Q 72-' To Existing or Abandoned System on Lot AJ.e__ ; On Adjoining Lots To Water Main/Service Line 2.0 To Cutback (if present) To Stream, Pond, Lake, or Major Drainage Course ro o To Driveway, Parking Area, or Vehicle Storage Area >L® Comments Cr+/a "IcW- D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Meets MOA Electrical Comments Dimensions Manhole/A (Y/N) Off" Level at Vent(Y/N) N Pumping Cycles during Adequacy Test. `*Check Permitted Bedroom Rating Against HAA Request" I certify that I have checked, verified, or conformed to all MOA and HAA guidelin4' q&�e of this If Q• : •. k inspection.,ems : '. 4 Signed e....... an k p Y �� � Com � , ,. .....•F:r+ Seal �0 /y a % 9 : ahoy . RFID, J Date % C - 2251 , MOA No. o *090040 *'I* �4'r � Receipt No. �rr �� Ig!%D Receipt No. Date of Payment L- :�� _ — Waiver Fee: $ Amount: $ e-) - CC) Date of Payment 72-026 (Rev. 7/88) Back Page 2 of 2 A `°S Cf ALASKA IR0111T1C11TAL, C011T110L SRUIUS, Inc. o 6n9ineerinq & Enuironmental Studies P. 0. Box 240668 Anchorage, AK 99524-0668 (907) 279-5553 *** FAX (907) 276-8706 November 29, 1989 Municipality of Anchorage Department of Health & Human Services 825 L Street, Fifth Floor !\AUNICIPALtTY OF ANCHORAGE Anchorage, AK 99501 DEPT. OF HEALTH & ATTN: Susan Oswalt ENVIRONMENTAL PROTECTION ;ur, 11989 RE: Lot 8, Block 3, Sand Lake #2 RECEIVED Dear Susan: This septic tank was situated at 98 feet from the Class C Well. The waivered distance to the well was 100 feet. I spoke to Mike Lewis, ADEC, about the possibility of a new waiver. He was not supportive of the waiver. It would be better to move the tank to the proper distance from the well. Around October 9, 1989, I inquired at DHHS about moving the tank and was told that as it was to correct an unapproved distance from the well, no permit was needed. However, the tank needed to be inspected by an engineer. The tank was moved on November 7, 1989. Per our phone conversation here is the inspection report on the MOA forms. 1412 WE5C 330 Avenue 0 Anchopage, AtASkd 99503 0 (907) 279-5553 A copy of this letter and inspection has been sent to ADEC for their files. Sincerely yours, Ler C. Reid, P PE, DEE resident LCR/sr ANCHORAGE WESTERN DISTRICT OFFICE 5636775 3601 C STREET, SUITE 322 ANCHORAGE, ALASKA 99503 November 6, 1989 Dr. Leroy C. Reid, Jr. Alaska Environmental Control Services 1412 west 33rd Avenue Anchorage, AK 099503 PWSID& # Class C According to the records on file in this office, the Sand Lake #2, Lot #8, Block #3 Water system is in compliance with the State of Alaska Drinking Water Regulations. Sincerely, Vera E. Cr ig Environmental Field Officer VECsbas ®0'M4r� 14 .cAt OF Az 11 b Bi °" °°O ° O �� o ° o 0 00 4 o o ym i7000°o a400 00 000eaoa 00 0° o 00000 ° 00 2251 ° e ALASKA ENVIRONMENTAL CONTROL SERVICES, INC. MROW HOW l Inc.. G.t.. W. 01411. JOB / 7 (; - 5--.-.'/ .1, A, zv a SHEET NO. / OF CALCULATED BY— DATE CHECKED BY DATE crei c .................... i f �i Jp �� ;1��•�{kms �OUV �+ �G3G3dQ�]D� polo �203 W. 15th AVE "C" SUITE 203 CHORAGE,ALASKA99501 CONSULTING ENGINEER TELEPHONE: (907) 279-3916 RESIDENTIAL WELL INSPECTION LEGAL: Lot 8, Block 3 Sand Lake #2 LOCATION: 8119 Seacliff OWNER: Alaska Housing Finance Corporation TYPE OF WELL: Class C Community Well WELL LOG AVAILABLE: Yes INSTALLATION REQUIREMENTS MET:Yes WELL YIELD FROM WELL LOG: 60+ gallons per minute DATE OF INSPECTION: September 2, 1988 TEST FOR E.COLI AND TOTAL NITROGEN: Water was tested for E.Coli and total nitrates on September 8, 1988 E.Coli 0. Total Nitrates. Non Detected. Max. allowable Total Nitrates 10ma/1. TEST RESULTS: This well meets the requirements of the Municipality of Anchorage, and the Department of Environmental Conservation. The Municipal requirement for well flow is 150 gallons of water per bedroom per day. This well exceed this requirement. The assessment of the condition of the well applies only to the conditions as of the day tested. The flow rate may change due to subsurface conditions that may not be observed from the surface, and changes in the land use and other factors that may impact the aquifer feeding the well. n 7'obben Spurkland P.E. Septic System Adequacy Test Lot 8, Block 3, Sand Lake Judy Pipkin September 14, 1988 The depression above the crib should be filled and the standpipe extended to 18 inches above ground level. When these repairs have been done and the residence converted to a single family, three bedroom residence, a Municipal approval can be requested. NOTE The operational life of all septic systems depends on the local soil conditions, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this septic system. We can therefore not give any estimate of how long this system will function satisfactory for current or future occupants. U O GGY1 �GG�G�LG�1D9 f�o�o 2 ANCHORAGE, ALASKA 99501 • CONSULTING ENGINEER - TELEPHONE: (907) 279-3916 SEPTIC SYSTEM ADEQUACY TEST LEGAL: Lot 8, Block 3, Sand Lake #2 LOCATION: 8119 Seacliff OWNER: Alaska Housing Finance Corp. RESIDENCE: Duplex, Five Bedrooms WELL: Class C SEPTIC SYSTEM: FROM MUNICIPAL RECORDS: Single Family, 3 Bedroom system TANK: 1000 gal Greer Steel, Two Comp. ABSORPTION SYSTEM: Concrete Ring Crib and Trench ABSORPTION AREA: 372 For Crib 420 For Trench 792 Total SOIL RATING: 206 per bedroom INSTALLATION DATE: Sept. 1982 DATE OF LAST PUMPING: Sept. 2, 1988 Isaacs Pumping DATE OF TEST: Sept. 2, 1988 TEST PROCEDURE: System was inspected and measured. Crib was 10.5 feet deep and dry. Stand pipe to pit was below ground. Ground had settled around crib. Sump to trench was 20 feet deep and had 6 inches of sludge in the bottom. The distance between the tank and the well was found to be 98 feet. 1000 gal. of clean water was added to the trench. This caused the water level to rise 46 inches. After 6 hours the level had dropped 9 inches indicating that 200 gallons had been absorbed in 6 hours. TEST RESULT: This residence is presently a duplex with a single family, three bedroom septic system. Under the present septic system ordinance a septic system to serve a duplex or a single family home with more than three bedrooms can not be installed on this lot. The septic system is adequate for a single family, three bedroom house. The residence is being served by a Class C well. The separation distances for.septic systems and Class C wells are 150 feet for both septic tank and absorption fields. These distances was waived by the Department of Environmental Conservation to 100 feet. The tank was measured to be :98 feet from the well, two feet less than required. A second waiver could be requested, or the tank exposed and moved. It is unlikely that the State will grant the waiver, since a waiver from 150 to 100 already has been granted. Time APPLIC/ IT FILLS OUT UPPER HALF' '7NLY Property cYwner ��� -- 1 - > Phone Mailing Address � , Zip Code Buyer "Y i- f `,ll Date Address Date ✓ I ' �� c Zip Code Lending Institution '' _ jT<, j f,_ `,�>' �,. �,�� fJ Phone Inspector l Address Vt� it 4Zv- Zip Code ( ) DISAPPROVED Realty Co. & Agent v ( ) CONDITIONAL APPROVAL` Phone Address DATE BY: Zip Code Legal Description j� Date Sewer Installed �— 9--f, Well To Absorption Area Well to Tank Well Log Received Septic Tank Size /p p 0 Street Location zL Type of Residence - Single Family OeC Multiple Family edrooms No. of Bedrooms- 0 ❑ Other Water Supply - ❑ Individual ATTACH WELL�LOG. A well log is required for all wells drilled since June 1975. 1� Oommunity For wells drilled prior to that date, give well depth (attach log if available). ''[LI Public Utility Sewer Disposal Individual `,u Year Individual Installed: t 7 SLS' ❑ Public Utility When Connected to Public Utility: ❑ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. Time Time Time Time Date Date Date Date ✓ I ' �� c Inspector Inspector Inspector Inspector Field Notes: i4 w Z) APPROVED BEDROOMS 'CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CONDITIONAL APPROVAL` DATE BY: v Soils Ratting ( 2- G/ '" Date Sewer Installed �— 9--f, Well To Absorption Area Well to Tank Well Log Received Septic Tank Size /p p 0 72023 (3182) Time APPLIC NT FILLS OUT UPPER HAI -''ONLY Pcaperty C)wnerQq X'gexe- - Phone Mailing Address V0 V(X ! � 3 C Pel �I/ Buyer Date Address Zip Code Lending Institution Inspector Inspector Phone Address Inspectors Pia A Zip Code MUNICIPALITY OF ANCHORAGE A ENVIR1-)iIh'.:P„A....v.°:,TION Realty Co. & Agent Phone Address RECEIYED Zip Code `CONDITIONS OF APPROVAL Legal Description o f a 7 lf�v 4 -2— ZStreet StreetLocation r Type of Residence - Well To Absorption Area Well to Tank ,�( Single Family ,n SepTic Tank Size ❑ Multiple Family `L No. of Bedrooms Other Water Supply ❑ Individual - _ J q nL-)C_'i) - n D i zT • ATTACH WELL LOG. A well log is required for all wells drilled since June 7975. ,ja Community - For wells drilled prior to that date, give well depth (attach log if available). ❑ Public Utility Sewer Disposal -.6--individual (7,, 1 ��� � I iii Of -q -u G �-- ❑ Public Utility Year Individual Installed: R When Connected to Public Utiry: ❑ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. Time Time Time Time CIL 4;L `�et Date Date Date Date - - Inspector Inspector Inspector Inspectors Pia A Field Notes: aff 4% --�p�„�d MUNICIPALITY OF ANCHORAGE A ENVIR1-)iIh'.:P„A....v.°:,TION RECEIYED ( ;�) APPROVED BEDROOMS `CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CONDITIONAL APPROVAL - DATE BY: Soils Rating Date Sewer Installed (! --' Well To Absorption Area Well to Tank Well Log Received ,n SepTic Tank Size S '� APS i)L- 12 -a Qu —4 s" ra--�-a LLD ta�. oxa 4l December 2, 1382 "Paul Bergeron c/o Oliver Tovsen, Jr. DBA T & `l' Construction Co. SRA Box 4035--A Anchorage, A` Subject: Lot €; Block 3 Sand Lake #2 Approval for the individual sewer and water facilities cannot be granted until the following items have been completed: ° A four (4) inch cleanout needs to be installed to the leaching area. The well serving; the subject property is a "Class C" corn- Ziunity water supply. the have-not received the approval on the State Department of environmental Conservation on is well. �� Please notify this Department for a reinspection when the noted discrepancies have been corrected. If there are any further questions, please call this office at 264-4720. Sincerely, Robert C. Pratt Associate Environmental Specialist RP240/p/EH M 5. LEGAL DESCRIPTION DATE RECEIVED s INSPECTION APPOINTMENTS TIME 6. TYPE OF RESIDENCE TIME TIME DATE SINGLE FAMILY -DATE DATE INSPECTOR 7. WATER SUPPLY INSPECTOR INSPECTOR PIC, * ATTACH WELL LOG. A well log is required for all wells drilled MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE since June 1975. For wells drilled prior to that date, give well DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION DEPT. OF HEALTi I & 825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL I'i:O T ECTION depth (attach log if available.) ENVIRONMENTAL SANITATION DIVISION Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWERUIEWE D DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROP TYOWNER/ NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. �PHONE E�l�'70�� C/1 rd �:PCrtai MAILING ADDRESS PROPERTY RESIDENT (If dif erent from above) PHONE 2. BUYER � PHONE MAILING ADDRESS 07 3. LENDING INSTITUTION - PHONE % oZ F� MAILING ADDRESS _ 4. REA OR/AGENT �7 v� PHONE '7 M N ,*DRESS ESS /J � `_Z M 5. LEGAL DESCRIPTION STREET LOCATION 6. TYPE OF RESIDENCE NUMBER OF,BEDROOMS ❑ One E:1 Four ED Other SINGLE FAMILY ❑ Two ❑ Five ❑ MULTIPLE FAMILY J Three ❑ Six 7. WATER SUPPLY f INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled ❑ COMMUNITY since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM INDIVIDUAL/ON-SITE** �� YEAR ON-SITE SYSTEM WAS INSTALLED. ❑ PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 (Rev. 6/79) THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE ❑ SINGLE FAMILY ❑ MULTIPLE FAMILY NUMBER OF BEDROOMS ❑ ONE ❑ THREE ❑ FIVE ❑ OTHER ❑ TWO ❑ FOUR ❑ SIX 2. WATER SUPPLY ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLIC UTILITY Connection Verified - PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM ❑INDIVIDUAL/ON -SITE ❑PUBLIC UTILITY Connection Verified PERMIT NUMBER DATE INSTALLED INSTALLER ❑Septi1c rTa/nyk^� or ❑ Holding Tank Size:-, ' If Tank is homemade give dimensions: SOILS RATING TYPE OF TANK MANUFACTURER - TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES WELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS E3`AAPPROVED FOR BEDROOMS ❑ CONDITIONAL APPROVAL (letter must accompany certificate) ❑ DISAPPROVED DATE / C BY 72-010 (Rev. 6/79)