HomeMy WebLinkAboutSAND LAKE #2 BLK 6 LT 5 Municipality of Anchorage On-Site Water and Wastewater Program• (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number OSP171018 PID Number: 011-133-32 Dwelling: ❑ Single Family (SF) ■❑ Duplex(D) ❑ Multiple(SF and/or D) Project: ❑ New ❑■ Upgrade Name: Terry & Mary Jo Dubie ABSORPTION FIELD Address [' Deep Trench ❑ Shallow Trench ID Bed El Mound 8243 Seaview St. El Other Phone Number of Bedrooms Soil Rating Total depth from original grade 907-830-9119 5 0.7 GPD/SF 6.3 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 5.8 Ft. 0.5 Ft. Sand Lake #2, Block 6, Lot 5 Fill added above original grade Gravel length Township Range Section 0.8 Ft. see plan view UFt. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES see plan viewpFt._see plan view see plan view Ft. To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Tank Line >220 Ft2 Ft. Well 784* 92'+* TANK a Septic ❑S.T.E.P. ❑Holding ❑Other Manufacturer Capacity Surface Water 100'+ 100'+ Anchorage Tank 1500 Gal. Material Number of compartments Lot Line 5'+ 2'+* Steel 2 - NA Foundation 5'+** 6'+* Septic Treatment Equipment Manufacturer Capacity 1 Curtain Drain None Known BioMicrobics RetroFAST 0.375 375 GPD '' Remarks Pump on level at Pump off level at High water alarm at * Per waiver OSV171009 ** One deck support is <5' from the tank and NA in. N_ A_ in. NA in founded on undisturbed insitu sand w/gravel. Blower make and model Electrical Inspections performed by Atlantic AB-81 MOA PIPE MATERIAL House to tank D3034Tank to D3034 Installer drainfield ARM Services Drainfield D3034 CO/MT D3034 Inspector Crewdson Engineering LLC BENCH MARK (Assumed elevation) 100 ft Ins dates: 1' 6-19-17 2. 6-22-17 Location and description 3r° 6-23-17 4th Top of asphalt driveway at NW corner of garage. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL I EngQ \ mp ds.OF ALgs;t1 Conditional Approval: Date ;qP•• r- .. 'II *:"49r . •.* ri s / /, ..J., es A.Crewdson.:A/ it J'. C11527 /► + ,.,(roll-t .• , g. Approved Gw. Date &-3c� -II 1 ........1.0'= Inspection Report_9-1-12.doc a m N N • I- I- I- O O O S00° 06' 00"E 50.00' X ------_-- X _.----X_ X NOTES: 1. EXISTING SEPTIC TANK SHED SHED DECOMMISSIONED IN ACCORDANCE WITH THE CODE. WELL 2.NEW 1500-GALLON SEPTIC TANK WITH , C Bio-Microbics RetroFAST SEPTIC TREATMENT SYSTEM. Ix 3. NEW>220-SF BED ADDED TO EXISTING DEEP TRENCH TO ACCOMMODATE 5-BEDROOMS. 4. EXISTING DEEP TRENCH DISTRIBUTION 0 LINE HYDRO-JETTED. ic 5.PER SIEVE ANALYSIS, INSITU i RECEIVING SOIL FOR NEW BED IS SAND. 6 LOT 5 6.ONE DECK SUPPORT IS<5 FEET FROM co THE NEW SEPTIC TANK AND IS FOUNDED Z ON UNDISTURBED GROUND DEEPER • THAN THE SEPTIC TANK. IIIIIMII ' EMI • O 2ND STORY O DECK x cola' LOT 4 5 BR DUPLEX LOT 6 s O x O *(7 -etroFAST BLOWER in No�CIt 0 u� `S A co NEW 1500-GAL SEPTIC TANK 1ST STORY• Z WIBio-Microbics RetroFAST I lel 2DECK x i;ONMI— ak 9 wF ST1 Rq=SC ST2 ' •tnctvebA • SWING TIES _ MH • B�f-r7 ••a'k C ST1-A 6.9' DC / _ MH2MT3 . x ST1-B 15.7' MT /,,,(E)DEEP CO5• • C01-A 23.4' See h; C01 . C01-B 15.3' �.r� TRENCH i t —= 01 CO2 A 42.9' CO2-B 31.0' - -- x MH2-B 24.0' NEW BE C04 PLAN MH2-C 9.2' _ x3,2,,,,'00. /\1 / CO2 SCALE: 1".20' R4pwS'tC 'yl T2 • PAVED DWY x Per Wa,vty OSV Moog oog /� CO3T 3 .N.SOO° 06' 00"E 50.00' SEAVIEW STREET Crewdson Engineering, LLC Sand Lake #2, Block 6, Lot 5 Septic System Record Drawing ••, _ Plan View 1,Fmes i.1527wdson�� Civil Environmental Engineering . •'p;;;�• `X 0 Prepared for: Terry Dubie Date: 6 -28 -17 AF DPROFESSIONP�`` PO Box 671389 Chugiak AK 99567 • cellc 1@outlook com Cell/Text 907-280-9493 • Fax 907-688-2295 Permit: OSP171018 Page: 2 of 3 L ALLC #112279 • BENCH MARK ELEV ELEV TOP OF ASPHALT EG 99.9' EG CO1 99.8' NW GARAGE CORNER FG 100.64' CO2 99.6' ASSUMED ELEV 100' FG CO1 100.62' CO2 100.41' MH2 FCO ST1 ST2 MH1 DC CO1 MT1 CO2MT2 CO3 C04 C05 MT3 NEW BED SEPTIC TANK JUNE, 2017 1500 GALLON >220 SF 1976 SOILS LOG W/RetroFAST 0.375 MEDIA IN SECOND 1-BEDROOM 1976 DEEP TRENCH LOCATION: UNK CHAMBER AND BLOWER AT GRADE ON ELEV: 34'L x 3'W x C'ED BOH 14.5' NORTH SIDE OF HOUSE INV 93.99' 4-BEDROOMS 100-SF/BR ELEV: BOF 93.47' GW: DRY TOT 94.91' INLET INV 94.32' NOTE: OUTLET INV 94.16' THE BED AND DEEP TRENCH ARE ONE COMBINED DRAINFIELD SIZED FOR 5-BEDROOMS LEGEND FC-foundation cleanout DRAWING NOT TO SCALE tE) existing FG-finish grade BEG-below EG GPO-gallons per day BOF-bottom of field GW-groundwater BOH-bottom of hole IAW-in accordance with HR-BEDROOM INV-invert CO -cleanout MT-monitor tube DC-double cleanout SF-square foot •OWY-driveway ST-septic tank cleanout EG-existing ground TOP-top of pipe ELEV-elevation TOT-top of tank Sand Lake #2, Block 6, Lot 5 SepticSystem 4P' •* 4g ., Record Drawing .., !' • ' James A.Crewdson Profile View '•• CC11527 •�� 6. Civil&Environmental Engineering /49.67%..e Prepared for: Terry Dubie Date: 6-29-17 17FESS10NP� fPO Box 671389 Chugiak AK 99567 • cellc 1 @outlook corn Cell/Text 907.2809493 • Fax 907-688-2295 Permit: OSP171018 Page: 3 of 3 ALLC #112279 Municipality of Anchorage Development Services Department P.O.• 'r 4-6', Box 196650-4700 Elmore Road ... ) Anchorage,Alaska 99519-6650 Info and Help: (907)343-8211 INSPECTIONS: Voice: (907)343-8300 Fax: (907)249-7777 6/26/2017 Inspection Report License/AP#: RETROE171284 Parent AP#: Inspection #: 461152 Type: RETRO Status: Closed Address: 8243 SEAVIEW ST APT A Parcel: 01113332000 Inspector: D.Rooney Project: Resp Party: Descr: Add circuit and hook up septic pump- BWP Inspection Electrical (Electrical Inspection) Item: Evaluation: Approved Result Notes: Electrical final approved for GFCI receptacle Inspection Item Item Description Evaluation Nc1PA1-�CY MUNICIPALITY OF ANCHORAGE On-Site Water&Wastewater Program PO Box 196650 4700 Elmore Road ,� ' Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 ` ^ http:/lwww.muni.org/onsite v parrifle nt �'MCNOP�'4 On-Site Wastewater Disposal System Permit Permit Number: OSP171018 Effective Date: 3/1/2017 Work Type: Septic Upgrade Expiration Date: 5/4/2018 Tax Code Number: 01113332000 Site Legal Address: SAND LAKE#2 BLK 6 LT 5 G:2224 Site Mailing Address: 8243 SEAVIEW ST, APT A, Anchorage Owner: DUBIE TERRY E & MARY JO Lot Size in Sq Ft: 6750 Design Engineer: CREWDSON ENGINEERING, LLC Total Bedrooms: 5 This permit is for the construction of: D Disposal Field D Septic Tank El Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: The engineer shall submit a sieve analysis of accepting soil to show 51% or more passes the#4 sieve. If sieve analysis does not demonstrate this, a 2 foot sand filter is required below the bed. Please submit results of sieve analysis. Received By: , Date: S.-07 G--� Issued By: f_ i, :�Y_.� .� Date: 5/2 a 01 "7 rA,rnr Municipality of Anchorage 1),partnlcnc P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http:llwww.muni.orq/Onsite Development Services Division On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#; OSV171009 COSA#: Permit#: OSP171018 PID#: 011-133-32 Legal Description: Sand Lake#2 Block 6 Lot 5 Engineer: Crewdson Engineering LLC Applicant: Terry Dubie Your request for a waiver of the required 100 feet horizontal separation from the absorption field and septic tank for Block 6 Lot 5 to the private well for Block 6 Lot 5 has been approved. The approved separation distances are 92.0 feet and 78.0 feet, respectively. In addition, your request for waivers of the required 10 feet horizontal separation from the absorption field to property lines and building foundation have been approved. The approved separation distances are 2.0 feet and 6.0 feet, respectively. This waiver approval applies to the proposed absorption field and septic tank only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. VI The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. n Adjacent properties are not affected by this waiver. Waiver is Granted: X Waiver is not Granted: Date: .5/-2(1/4011 Approved by: "-t e c y- Cp,-u-cz- Name of Reviewer *'k** VARIANCE/WAIVER REVIEW **** Sand Lake #2 Block 6 Lot 5 Parcel ID: 011-132-31 Waiver for 78 feet from well to septic tank Issued 05/26/2017 General Original well and septic system installed in 1976. 2017 water sample shows ND for nitrate and negative for E. Coli and total coliform. ADEC Criteria Points Water Table Depth to water bearing layer 398 feet Depth of tank 10 feet 388 feet 8.1 Soil Sorption Soil descriptions per well log DEC PTS Depth From Depth To Thickness Calc. Pts Organics 0 0 2 2 0.00 Sand 1.5 2 18 16 0.06 Gravel 0 18 23 5 0.00 Sand 1.5 23 78 55 0.21 Silty Sand 2 78 278 200 1.01 Hard Pan 1 278 378 100 0.25 Silty Sand 2 378 398 20 0.10 398 1.62 1.6 Permeability Soil descriptions per well log DEC PTS Depth From Depth To Thickness Calc. Pts Organics 0 0 2 2 0.00 Sand 1.5 2 18 16 0.06 Gravel 0 18 23 5 0.00 Sand 1.5 23 78 55 0.21 Silty Sand 2 78 278 200 1.01 Hard Pan 0.9 278 378 100 0.23 Silty Sand 2 378 398 20 0.10 398 1.60 1.6 Water Table Gradient- Not calculated XX Horizontal Separation 78 2.1 Total Points 13.4 As per ADEC waiver guidelines, with a minimum point value of 13.4, no bacteriological pollution possible but chemical pollution possible but unlikely from household chemicals, Well and septic have been in place for 40 years and water test do not show E. Coli, coliform or nitrates, therefore waiver approved. . a/ MUNICIPALITY OF ANCHORAGE ( • g,Z°,kw' Community Development Department ` 'J Phone: •: -343-7904N Development Services Division F. =t• , •• >. On-Site Water & Wastewater Program ti A ON-SITE SEWER/WELL PERMIT APPLICATION a FEB 2 1 201l 3 I6 ti Parcel I.D. 011-133-32 �!! 01 5 e L 9 *�' Property owner(s) Terry & Mary Dubie Day phone 1. - AR 1 P1m.r1 3. Mailing address 5243 Seaview Street #A, Anchorage, AK 99502 g JC_ 91161 i ee rry Site address 8243 Seaview Street Legal description (Sub'd., Black & Lot) Sand Lake #2, Block 6, Lot 5 Legal description (Township, Range & Section) Lot Size 6,750 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field 0 Initial ❑ Single Family (SF) ❑ (w/wo ADU) Septic Tank Q Upgrade EI Duplex (D) El Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Septic to well. / Septic to lot line / 1 ,rcL . - G ` 0cics4;on Distance: '1`572 Vr I (o 6k I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. 1\(2 (Signature of prop rty owner or authorized agent) Permit/Rush Fees: i46-661 Waiver Fees: iti/As •a) Date of Payment: Mg.1/7 Date of Payment: .6ligi I? Receipt Number: n Receipt Number: 65-W -6 Permit No. 3SPIl-k5/$ Waiver No. U5V !ilati Permit App_2 :• ::_.-c.; Crewdson Engineering, t.t.0 James "Jay" Crewdson, P.E. Email: CELLC.1@outlook.com Cell/Text: (907)280-9493 Fax: (907)688-2295 Baca. Civil&Environmental Engineering May 25, 2017 Onsite Reviewer Municipality of Anchorage On-site Water&Wastewater Program 4700 Elmore Road Anchorage,AK 99519-6650 Reference: Sand Lake#2, Block 6, Lot 5 Permit OSP171018 and Waiver OSV171009 Change Order 1: New Engineer and Septic Design The owner of the subject property (5-bedroom duplex) has decided to retain Crewdson Engineering LLC (CE)to complete the project. Change Order 1 is CE's proposed design. The existing septic system needs to be upgraded. The following is a list of the issues that need correcting and the proposed upgrades. 1. The septic tank and drainfield are undersized by one bedroom. a. Design proposes to i. Decommission the existing septic tank ii. Install a new 1500-gallon septic tank, and iii. Increase the size of the existing drainfield to accommodate five bedrooms. 2. The existing drainfield pipes need to be thoroughly cleaned and the drainrock needs to be remediated. a. Design proposes to i. Hydrojet clean the drainfield distribution pipes ii. Install a Bio-Microbics RetroFAST 0.375 treatment system to remediate the drainrock. Please revise waiver to be for the following separation distances only, which are slightly less than what's shown on the drawing to allow for small adjustments to the design during construction. 1. Subject property well to a. Proposed septic tank: 78 feet b. Proposed drainfield: 92 feet i. JUSTIFICATION: 1. A recent well water analysis for a coming COSA shows Nitrates (Non- Detect)and Coliform Bacteria (negative) are both good. 2. Surface Pollution:The property is relatively flat and is likely to cause any overflowing sewage to have substantial pooling on the ground surface PO Box 671389 • 18368 Amonson Road • Chugiak, Alaska 99567 Page 2 of 2 May 25, 2017 Sand Lake#2, Block 6, Lot 5 Permit O5P171018 and Waiver OSV171009 Change Order 1 before migrating to the well. The well is on the opposite side of the house from the septic tank and drainfield,which are both located near the main entrance to the house and the garage. As such, any overflowing sewage is likely to be seen and taken care of long before it has an opportunity to flow around the house to the well. 3. Sub-surface Pollution:The well depth is 407 feet with a static water level of 143 feet, which means it's pressurized to 113 psi [(407 ft. — 143 ft.) x 0.43 psi/ft.= 113 psi]. The aquifer's high pressure at this location clearly indicates it's very confined and as such would be near impossible to pollute from the subject property above. 2. Property line to proposed drainfield: 2.0 feet a. JUSTIFICATION: i. The undersized lot doesn't have any available room to locate the drainfield away from the property line. ii. The drainfield is not likely to have any adverse effects to the adjacent right-of- way to the south. The edge of street pavement is currently greater than 10 feet from the proposed drainfield. iii. The drainfield is not likely to have any adverse effects to the adjacent private property to the west. The septic tank for this lot is approximately 9 feet from the proposed drainfield. 3. Foundation to proposed drainfield: 6.0 feet a. JUSTIFICATION: i. The undersized lot doesn't have any available room to locate the drainfield away from the foundation. ii. The drainfield is in fast percolating soils that are not likely to allow effluent to migrate laterally to the foundation. A very small portion of the drainfield is located less than 10 feet from the foundation and as such is not likely to have any adverse effects on the foundation. OFAO4�) Please feel fe to con .ct e if .u have any questions. % ' 49 " IL to 1 �/ es A. Crewdson /` J+• C11527 • i James "Jay" Crewdson, P.E. (i IA;• a?S=f�,•� 1 \\TOFESSIQ P:ft? NOTES I I ! 1.THE SEPTIC UPGRADE INCLUDES A RetroFAST SEPTIC TREATMENT SYSTEM. � 2.ALL WIRING SHALL BE COMPLETED I _ I BY A LICENSED ELECTRICIAN. I /LL I ; 3.THE DESIGN ASSUMES INSITU SAND. i 'li IF FOUND TO BE GRAVEL,A 2'SAND LINER SHALL BE INSTALLED UNDER THE DRAINFIELD. 4.ALL PROPERTY LINES,EASEMENTS PLAN AND WELL RADII WITHIN 20 FEET OF THE PROPOSED SEPTIC SYSTEMI SCALE: 1"=20' SHALL BE FLAGGED PRIOR TOI LOT 5 I LOT 6 / CONSTRUCTION 5. DUE TO THE LACK OF AVAILABLE / SPACE,THE EXISTING DRAINFIELD I WILL BE REBUILT FOR THE RESERVE. 5/ 7:.6 �� • LOT 4 e••.1 10°� I7 (, ii-_-_ k _ / FC / N.. 5'+ r A (P)1500 SEPTIC TANK ' 13' 5 BR DUPLEX I / N W/RetroFAST TREATMENT S1 SYSTEM IN SECOND / CHAMBER I L I ti� S2 \ /51+ ���4�p1i3�. (E)1250 SEPTIC TANK — MT .I 6'+ 1Op� DECOM IAW CODE • Rirmi PAVED DWY (E)SEPTIC TANK EA5)' YDROJET I (E)4-BR 100'WELD R4DIUS 3 -EMOVE LARGE DRAINFIELD TREE _ v CO PLACE AROUND(E) �4,, 1 CO REMOVE PAVEMENT I1.1100. WALL�p\t1s 1250 SEPTIC TANK, -M / AS NEEDED / 214-SF MIN AREA : LEGEND DESIGN REQUIREMENTS (E) existing FG-finish grade TH-CTL76. <1-MPI,BOH 15'.DRY (P) proposed GPD-gallons per day BEDROOMS:4(E)+1(P)=5 TOTAL BEG-below EG IAW-in accordance with APPL. RATE: 0.7 GPD/SF BOH -bottom of hole MPI-minute per inch AREA: 214 SF(1 BEDROOM) CO-cleanout MT-monitor tube BED: 214-SF MIN AREA DC-double cleanout SF-square foot EFFECTIVE DEPTH: 0.5' DWY-driveway S#-septic tank cleanout TOTAL DEPTH: 6.5' EG-existing ground 1500-GAL SEPTIC TANK FC-foundation cleanout Crewdson Engineering/ LLC Sand Lake #2, Block 6, Lot 5 P Septic Design ` ..,.*••% Plan View Change Order 17:11).(../- °I;LNA.Crewdson .•4, fi "• "11527 •�� Civil&Environmental Engineering lF�PRpFEss•0� �� PO 8ox 871389 Chugiak AK 99567 • cellc.lQoutlook cotn Prepared for: Terry Dubie Date: 5-26-17 CelUText 907-280-9493 • Fax 907688-2295 Permit: OSP171018 Page: 1 of 1 ALLC #112279 1 M-W DRILLING, Inc. P,O. Box 110378 S 10330 Old Seward Highway v 7-12.2 (907)349-8535 ANCHORAGE,ALASKA 99511 DRILLING LOG Well Owner Scott & Donna MacKenzie / 1st GMCA Use ofygelt ;.domestic Location (address of: Township, Range, Section, if known; or distance main road L5 , B6 Sand Lake Subdivision, No. 2 Size of casing 13" Depth of Hole 4°7 feet Cased to 407• 70 feet Static water level 1 40 it. (4404. below) land surface. Finish of well (check one) open end ( ); Screen ( ); Perforated ( Describe screen or perforatio •' Well pumping test at 2(2ga } (minute) for hours with IOQ`ta ft. of drawdown from static Ie:`'i Date of completio IS Dec Pi WELL LOG Depth in feet from P ground surface Gr l+ie details Cf formations penetrated, size of material, color and hardness t) TO 2 4144_cltu? i TO 4 1b soi I TO 20 $rt►wm sand = TO 25 $roam travel 5 TO 60 041fn 'sand 31 TO 14 ) 111 t7.jand 14.) TO 1110 51 L t7 s find t ?±4§0 1.6') TO 2 Gra/ silty sand (wet) TO 300 Gray hard pan e4 3 Y) TO 360 ._ Gray hard Dau I;) 3E t3 TO 3: 0 Gray hard nan 36J TO 400 Gray 3ilty sand - water_ i,eari4 'yf2 l70 401 TO 407 Later. aa�z.I i;x'�ivel • 44,;;/ TO TO lorNA Certified Contractor • Certificate No's- "14 " 22—STATE • I SGS Ret# 1170526001 Client Name Pannone Eng.Sri. Printed Date/Time 02/20/.2917?9 14:25 Project Name/ti 8243 Seaview St. Collected DateiTime 02/06/2017 11:30 Client Sample ID 8243 Seaview St. Received Date/Time 02/07/2017 13:03 Matrix Drinking Water Technical Director Stephen C.Ede Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Dale Date Init Metals by ICP/MS Arsenic 28.2 * 5.00 ug/L EP200.8 C (<10) 02/16/17 02/20/17 VDL waters Department Total Nitrate/Nitrite-N ND 0.100 mg/L SM21 4500NO3-F B (<10) 02/08/17 AYC Micro Lab-Provisionally Certified as of 020817 L (oli Negative I 100mL SM2I 9223B A 02/07/17 DSH Total Coliform Negative 1 100mL SM2I 9223B A 02/07/17 DSH ______SGSi I SGS Ref.# 1172210001 Client Name Crewdson Engineering LLC Printed Date/Time 05/12/2017 16:52 Project Name/14 Sandlake#2 861.5 Collected Date/Time 05/10/2017 13:30 Client Sample ID Sandlake#2 86 L5 Received Date/Time 05/10/2017 13:35 Matrix Drinking Water Technical Director Stephen C.Ede Sample Remarks: Allowable Prep Analysis Parameter Result, LOQ Units Method Container ID Limits Date Date Ina Waters Department Total Nitrate/Nitrite-N NE) 0.100 mg/L SM2I 4500NO3-F 13 (<10) 05/11/17 AYC Micro Lata-Provisionally Certified as of 020817 E.Coli Negative I 100m1. SM2I 92238 A 05/10/17 ACF Total Coliform Negative I I00mI. SM21 92238 A 05/10/17 ACF Page 2 of 5 ev GIKt-A-, zR ANCHORAGE AREA BOR N Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 NAME LOCATION INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM aLF16:;\DDRESS LEGAL DESCRIPTION PHONC W-"// SEPTIC TANK: DISTANCE nn NUMBER OF FROM WELL 00 MANUFACTURER i�(lt% �PkATERIAL �a�lei-� cCOMPARTMENTS �o INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY42i�(:�ALLONS. ITC�ZTF(/i I IVT'T'CCO: ( < TOTAL LENGTH DISTANCE FROM WELL �� , FOUNDATION! f- NEAREST LOT LINE__ /_OF LINES S NUMBER OF LINEDISTANCE BETWEEN LINES TRENCH WIDTI- IN. TOTAL EFFECTIVE ABSORPTION AREA �Qd SQ. FT. LENGTH OF EACH LINE DEPTH OF FILTER DEPTH: TOP OF TILE TO FINISH GRADE MATERIAL BENEATH TILE .� IN. ABOVE TILE IN. WELL: TYPE- '� !/ �� CONSTRUCTION BUILDING NEAREST FOUNDATION LOT LINE CESSPOOL , OTHER SOURCES APPROVED c/ DISAPPROVED DISTANCES: INSTALLED BY: SEWER LINE DEPTH: PIPE MATERIAL: b' VA,(InnLL "i LOT SLOPEh: Lt -x'&, „ REMARKS: �Qo Form EQ -032 NEAREST SEWER LINE REMARKS SEPTIC TANK_ DEPTH DISTANCE FROM: SEEPAGE SYSTEM_ DIAGRAM OF SYSTEM DATE�O/PPROV ED � ]z� � ^M �N ' HFAND ENVIRONMENTHL, iOTECTION ^� ' 2516 E^°(UDOR RD. HNCHORHGE/ HK. _"`07 /��- , 276�.... .... 21 y . 0�0 E-_ E__ P_ PERMIT NO. ( 76826 ) ^' HPPLICANT ANDREI BUCKHREFF ' 6]4 N. HOYT 2 1 LOCATION SEH VIEW ST LEGAL L5 B 6 SAND LAKE SUB DIV #2 LOT SIZE 6750 SQUHRE FEET TYPE 0F SOIL HBSORBTION SYSTEM IS: TRENCH MHXIMUM NUMBER OF BEDROOMS 4 SOIL RATING (SQ FT/BR).­ 100 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: �������� �� ������=� �� THE LENGTHDIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRHINFIELD THE DEPTH OF H TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTT0el OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCHVHTION (IN FEET). ��� ����� � ���� �I ��� ������ ��...... ..... � J H-4� ­ff- 04 C-11 < -_a I P -.o 1-5" 0__ll 1E, c I` -V 1 C) F:7u �������C, j I BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION MINIMUM DISTANCE BETWEEN H WELL AND HNY ON-SITE SEWAGE DI5P0SHL SYSTEM IS 100 FEET FOR H PRIVHTE WELL OR 200 FEET FOR H PUBLIC WELL WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPHRTMENT WITHIN ]0 DHYS OF THE WELL COMPLETION. SPECIFICATIONS ANC, CONSTRUCTION DIHGRHM5 ARE' AVAILABLE TO INSURE PROPER INSTHLLHTION. �����_T ����IC. 9:;" Co P-4 E" F='F< CH V 9 I CERTIFY THAT 1: I HM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS Al-'-":; SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. ' ]: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLHRGEMENT IF THE RESIDENCE IS R [CELED TO INCLUDE MORE THAN 4 BEDROOMS. SIGNED: - c��__�l ISSUED B ___DHTE___.~_-.......l- _ 0"- »(� - ^� ` IL -el ~ t_�onitzuction gait "One test is worth a thousand opinions" 2204 Cleveland Anchorage, Alaska 99503 Perfdrmed For Andrei Buckaress Date Performed 9/29/76 Lenal Oescrintion: Lot 5 Block 6 Subdivision Sandldke Subdivision This Form Renorts Soils Loq yes Percolation Test_ Penth Feet gi, Characteristics 2 Fine Brown Sand 4 — Sand Gravel (GW/GP) 6- 0 Gravelly Sand (GW/GP) 10 — 12 - 14—. 16— Bottom of Test Hole 18 — 20 Was Ground Water Encountered? No If Yes, At what Denth? Readinq I Date I Gross Time 0 Net Time Depth to H2O Net Dron Percolation Rate Hinute Proposed Installation: Seenaae Pit Drain Field Deoth of Inlet Depth To Bottom Of Pit -Or Trench CnMFAENTS: 100 square feet drainage area rt-rmirpr7 pPr har7rnnm No around water or bedrock encountered_ Test Performed ByDavid Paul, CONSaEUCT QN Data Certified &�Y~:) �� , - �..t.zj ' r TEST LAB Date:9/30476 _ C ,,mss-L'.1�C" '��✓ -�-� Gsr,�-�- f, T . n� c�> � ..— / _") � �, �..�..��n.�� . �-fir c�',--��.->✓,.,�-�I_, �;�'�, ,��_ _ yLL. .lam . G/ai/.LIi 1.�,:�.Y f� �� -=%%.J -: �/ �:....i4(•-si>_1 /....tz�---A . Val MunicipaRty ®f Anchorage On-Site Water and Wastewater Program` (907) 343-7904 S A E T T Certificate of On-Site Systems Approval Parcel I.D. 011-133-32 Expiration Date: �2 1. GENERAL INFORMATION: Complete legal description SAND LAKE #2• BLOCK 6, LOT 5 pLocation (site address) 8243 Seaview Street *Anchorage Current Property owner(s) Richard & Angela Racette Day phone 575-0876 y Mailing address U> Z Real Estate Agent Day phone 2. TYPE OF DWELLING: Single Family (wiwo ADU) Duplex Multiple Dwellings (Single Family and(or Duplex) 3. NUMBER OF BEDROOMS: 5 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class ^Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver/Variance request for. Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ g0 Waiver Fee $ Date of Payment/nnU'' Date of Payment Receipt Number V 9 6i7 Receipt Number COSA # 01-S Q. A a XM 0 Waiver # MOR 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Gamess Engineering Group. Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: --=1-1 3o 2 -Z In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the systems on the dates of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational fife of all wells and septic systems depend upon a variety of variables, including but not limited to, soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the systems. These conditions can vary, andl' are outside the control of GEG. Satisfactory test results do not guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail to perform adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. 6. !TIGNATURE System #1 Approved for s� bedrooms System #2 Approved for Disapproved Conditional approval for bedrooms bedrooms, with the foil CES 0 i By- �/ Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of Onsite Systems Approval (COSA) based only upon the representations given In paragraph 5 by an independent professional civil engineer registered In the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions In the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Nitrate Advisory Septic System Advisory Arsenic Advisory_ Well Flow Advisory Other Legal Description: SAND LAKE #2; BLOCK 6, LOT 5 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 12/1s"6 Total depth 407 ft Cased to 407 ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) 12+ in. Date of flow test for COSA 8/1/22 Parcel ID: 011-133-32 Structure served by this system 013) Well production at time of test 3.8+ gpm Water storage tank volume N/A gallons II disinfected for coliform ❑ Yes ❑ No Coliform bacteria is eN gative . Nitrate mg/L V1 Nitrate less than MRL (ND) Arsenic '3Z -I ug/L ❑ Arsenic less than MRL (ND) Collected by GEG, L Date of Sample 8/1/22 Static water level at beginning of test 142.2 ft. Comments OWNER REPORTEDLY BLEACHES HIS WELL PERIODICALLY TO ADDRESS SULFUR SMELL B. TANK DATA Age of tank(s) 5 years Tank type/material SEPTIC/STEEL Measured operating fluid level in septic tank 48" ❑ Standpipes/foundation cleanout per record drawing Date of pumping 7/12/22 D. ABSORPTION FIELD DATA C. LIFT STATION ❑ Required maintenance completed Age of lift station ye Lift station material Commen Which system tested (date installed) 6/23/17 & 11/4/76 Adequacy test date 8/1/22 ❑ ALL standpipes present per record drawing Results (✓ Pass For 5 bedrooms Total measured depth from grade *13.5 ft (max) Fluid depth prior to test 2.5 in Measured depth to pipe invert from grade 6.0 ft (min) Water added 811 gal ❑ N/A — pressurized field New depth 2.5 in ❑ Monitor tubes go to bottom of effective. If not, state Elapsed time 0 min depth into effective p ❑ Code -required soil cover over field Final fluid depth 2.5 in ❑ System presoaked Absorption rate 750+ gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) NIA date of test) NONE Gallons introduced N/A gallons If yes, enter date Comments/Deficiencies:*AT SOUTH END OF 1976 TRENCH PORTION. TESTED BED PORTION OF DRAINFIELD AND BED LIQUID LEVELS REMAINED THE SAME THROUGHOUT TEST, AND TRENCH LIQUID DEPTF REMAINED THE SAME AT 23" THROUGHOUT TESTING. MT2 IN BED REMAINED DRY THROUGHOUT TEST. COSA Checklist yellow sheet E. SEPARATION DISTANCES 4� From Private Well on Lot to: (Please enter distances if less than required or if community well) f Septic Tank/Lift Station on Lot > 100' *78+ Community Sewer Manhole/Cleanout > 100' F1Yes if No ft Q Yes if No ft t<, 1 Neighboring Tank > 100' [j Yes if No ft Private Sewer/Septic Line > 25' M✓ Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No *92+ ft Holding Tank > 100' D Yes if No ft Neighboring Absorption Fields > 100' Animal Containment > 50'Yes ❑ if No ft •� Q Yes if No ft Manure/Animal Excreta Storage > 100' a Community Sewer Main > 75' n Yes if No ft R Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations :10' ❑ Yes if No aft Surface Water > 100' Yes if No It Property Line > 5' 0 Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ❑ Yes if No 41 ft Private Wells > 100' 0 Yes if No ft Water Main > 10' Q Yes if No ft Community Wells > 200' 2] Yes if No ft Water Service Line > 10' Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Yes if No *6+ ft If absorption field is under driveway comment below Property Line > 10' ❑ Yes if No *2+ ft Wells on Adjacent Lots: Water Main > 10' Q Yes if No ft Private Wells > 100' 0 Yes if No ft Water Service Line > 10' n Yes if No ft Community Wells > 200' Q Yes if No ft Surface Water > 100' [l Yes if No ft F. ENGINEER'S COMMENTS *WR#171009 SEE COMMENTS ON 2017 COSA BY JAMES CREWDSON P.E.REGARDING RETROFAST TREATMENT SYSTEM INSTALL, 1976 TRENCH IS UNDER DRIVEWAY. ***APPROXIMATELY 1 00'FROM WELL ON LOT 21 ****SEPARATION TO SEPTIC TANK ON BLOCK 6, LOT 79009MMWMFPM UNABLE TO BE DIRECTLY MEASURED So o o -r v6A;(F%6 G. ENGINEER'S CERTIFICATION l certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with y �� ,rp T MOA COSA guidelines in effect on this date. .. .Y....:... t7� J�ffrey A. orness: CE COSA Checklist yellow sheet r o f e s sion°©`=' #AECC884 N.§Z 96 www.muni.org/onsite Arsenic Advisory Certificate of On -Site Systems Approval # OSC221490 Subdivision: Sand Lake #2 Block 6 Lot 5 A water sample revealed an arsenic concentration of 32.1 micrograms per liter (ug/Q. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. information on arsenic is available from the On -Site Water and Wastewater Program website (www.muni.org/onsite) or at 343-7904. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. �c• so 7----7--.t Municipality of Anchorage ,.. .�:�_ P tY \\ // On-Site Water and Wastewater Program " LI] i. (907) 343-7904 SA r[T T Certificate of On-Site Systems Approval J�] Parcel I.D. 011-133-32 Expiration Date: q 9 -30- ` 1. GENERAL INFORMATION Complete legal description Sand Lake #2, Block 6, Lot 5 Location (site address) 8243 Seaview St. 'Current Property2owner(s) Terry & Mary Jo Dubie Day phone 907-830-9119 • Mailing address Real Estate Agent • : Tammy Stewart/Keller Realty Day phone 907-360-1116 2:-. TYPE OF DWELLING: El .Single Family (w/wo ADU) Q Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 5 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual Q Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for- Distance: y -_---�- Received by: / - Date: COSA to be relea -d . e engineer,unless otherwise requested by the engineer. Please allow 14 owner or owner's realtor to pick up the approved COSA. 5---Q- -k- I COSA Fee $ 2 bg - (AWaiver Fee $ Date of Payment G-2 g' 17 Date of Payment Receipt Number O ¶('0Z3 / Cj Receipt Number COSA# (9S c 1 11 Z to s Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Crewdson Engineering, LLC Phone 907-280-9493 Address PO Box 671389, Chugiak, AK 99567 Engineer's Printed Name James Crewdson Date 6-29-17 Note: as engineer of record, the information I have provided on this form satisfies MOA CecL -Site Systems Approval requirements only, and does not include any statements or guaranteeatstaeliFgAile Vie life and serviceability of the subject systems. S Y i y� �-.1� . 5,��111 6. DSD SIGNATURE r /, * // KSystem #1 Approved for ',bedrooms 7 ' t System #2 Approved for bedrooms .,1�'es A.Crewdson : Disapproved Ilia, 0,iiiii 6 x017 �=i Conditional approval for bedrooms, with the following stip ESS0v*, l Aix. 1 °It ,4L F, c`s4 `� 0') '`4 ✓b' . . 14 Q cti e f /s by 1`' 1 ads A-f'r Ne ` eft4 / 226C ;- -�14.J c y& F ' U , l S ' ,• v✓ 5 6d ru-�.� c..),"'''''�`y-�l�F y 3 p Wp-tER AN 0 WAS-tEVU?��R pRCGR ,.4_,,, c- ••.• am'. • );`•.ire i nr0\1\C. By: '"'"' G --c (1Original Certificate Date: r .36 -17 The Municipality of Anchorage Development Services Department (DSO) issues a Certificate of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet j •- c If more than 1 septic system is on the lot: Clued 1f11 8 COSA Checklist# of Structure served by this system FROM WELL LOG Certificateof On-Site Systems Approval Checklist Legal Description: Sand Lake#2, Block 6, Lot 5 Parcel ID: 011-133-32 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (YIN) Y Date completed 12/15/86 Sanitary seal (YIN) Y Wires properly protected (Y/N) Y Total depth 407 ft Cased 407 ft. Casing height (above ground) 30in. FROM WELL LOG AT INSPECTION Date of test 12/15/86 5/10/17 Static water level 140 ft143 ft. Well production 20 g.p.m. 3+ g p m WATER SAMPLE RESULTS: Coliform Neg colonies/100 mL Nitrate ND mg/L 64 Arsenic a1'-- ug/L Date of sample 5-10-17 Collected by. Crewdson Engineering B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 6- 1 9- 1 7 Tank size 1500 gal. Number of Compartments 2 Cleanouts (YIN) Y Foundation cleanout(Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping New Tank Pumper New Tank C. ABSORPTION FIELD DATA Date installed 11-4-76/6-23-17 Soil rating (ft2/bdrm/gpdgpd/ .7 System type Deep Tr/ Bed-- Length 34/see Insp.Rpt. ft. �.a".� Width 3/see Insp Rpt ft. Gravel below pipe 6 10.5 ft. Total depth 1 216 .3 ft. Eff, absorption area 500/>220 sf Monitor Tube Y Depression over field N Date of adequacy test 5/10/17 Results Pass For 4 bedrooms Fluid depth in absorption field before test 2 8 in. Water added 600+ gal. New depth 7 5 in 1C Elapsed Time: 1440 min. Final fluid depth 28 in. Absorption rate >= ("COI- d. Any rejuvenation treatment(past 12 mo.) (Y/N & type) N If yes. give date - The 1976 Deep Trench was adequacy tested prior to installing the 2017 Bed. The 2017 Bed was installed to increase the drainfield size to 5-bedrooms. D. LIFT STATION NA Date installed Size in gallons Manhole/Access (Y/N) _. "Pump on" level at in. "Pump off' level at in. High water alarm level at in Datum Cycles tested Meets alarm&circuit requirements'? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 78'+** On adjacent lots 100'+ Absorption field on lot 92'+ On adjacent lots 100'+ Public sewer main 75'+ Public sewer manhole/cleanout 100'+ Sewer/septic service line 25'+ Holding tank 754 Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+*** Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ ABSORPTION FIELD ON LOT TO: Property line 2'+** Building foundation 6'+** Water main 10'+ Water Service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 0' Curtain drain none known Wells on adjacent lots 100'+ F. COMMENTS * Crewdson Engineering did not sample for Arsenic given the owner had already decided that it was too high and has now installed a Point-Of-Entry whole house water treatment system to remove Arsenic. The buyer is aware of this also. ** Per waiver OSV171009. ***One deck support is <5' from the tank and is founded on undisturbed insitu soil that does not rely on the tank for structural support. ****A Bio-Microbics RetroFAST septic treatment system was installed to both rehabilitate the 1976 Deep Trench and to help ensure continued satisfactory performance from the combined Deep Trench/Bed drainfield. G. ENGINEER'S CERTIFICATION `��N�N.\\` I certify that I have determined through field inspections and �vollm .•' s �+ review of Municipal records that the above systems are in y•• �ti ,I9 rr conformance with MOA COSA guidelines in effect on this date. / :. ag •/\ i*.// Engineer's Printed Name p��v`?S Cr.-8'c.I dSotr, / �`—` Date 6 -- 14-/-7*- �, Jpimes A, Crewdson 11%,• C11527 n `i Note: as the engineer of record, I have provided information on ��#',p�;•• )-e2°t-j'�..•4?' this form intended to satisfy MOA COSA requirements only, and ���pR� SS10.P`� it does not include any statements or guarantee regarding the \�V `N.�—*•. future life and serviceability of the subject systems. ALL C 1 )a t q COSA canary sheet_2-6-15_CE pdf • Municipality of Anchorage -"fteDevelopment Services Department ==-- _=; _l'=_ Building Safety Division 5,,E,. On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Arsenic Advisory Certificate of On-Site Systems Approval # OSC 171265 A Certificate of On-Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block 6, Lot 5 of Sand Lake #2 Subdivision. This inspection revealed an arsenic concentration of 28.2 micrograms per liter (ug/L) for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Information on arsenic is available from the On-Site Water and Wastewater Program website (www.muni.org/onsite) or at 343-7904. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval. • LOT 4 LOT 21 2ND STORY 30' DECK N89°55'00"W 135.00' -------x — x ----x • - - x x X X - © 1ST STORY 5.3' DECK I SHED © SEPTIC TANK�-- 30.0' ACCESS LID C`�3`-1f� MO --1 W -- i - 11 - W-.w-32.5' 18.2' to W oSEPTIC FIELD SHED LOT 20 CLEANOUT LOT 5 8 W - EXISTING HOUSE N Cl) SEPTIC FIELD * • CO ACCESS LID.. v ,, a7.. Fs3 ;ua .mr., x. 55 00000p00 30' .—.-- x.....- — x x- x X x -- X_-- X x x OF A L app N89"55'00'W 135.00' ovP��c..'.......••-.4Sp�Q „ LOT6 I LOT 19 a. .• 49TH ••. .vA O lif VA . • /h STEVEN CALLA AN. o Q VA 1• L X-122034 �°Q Op�a61)..1. . Q � �>�a p� 1040000�46� NOTE: THIS DRAWING SHALL NOT BE MODIFIED FOR USE AS A PLOT PLAN LEGAL WITHOUT THE EXPRESSED WRITTEN CONSENT OF LCG LANTECH. 250 H Street DESCRIPTION: AS-BUILT ADDRESS: 8243 SEAVIEW STREET PARCEL#:011-133-32-000 Anchorage,Alaska 99501 ., am. SURVEY CERTIFICATION:LCG LANTECH,INC HAS CONDUCTED A PHYSICAL SURVEY OF `'� LOT 5, BLOCK 6, THE PROPERTY AS SHOWN ON THIS DRAWING AND CERTIFIES THAT THE Survey Department Phone 562-5291 SAND LAKE SUBDIVISION No. 2 LEGEND: IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND NO ENCROACHMENTS EXIST OTHER THAN NOTED. antiBCI” Mainline .-. 1 Inc DRAWN DATE: 6/27/2017 WORK ORDER:17040 . Asphalt � �66 Phone 243-8985 --WN B ---- --- - SEPTIC STANDPIPE 0 ... . .. EXCLUSIONARY NOTE:R IS THE OWNERS'RESFUNSIBILTTY TO DETERMINE THE a�eCvl,[.t`.fCiuAe' frTl�(itCP/ilru�"Ac✓u"e DRAWN BY: AP PLAT: P-176 -_- WATER WELL ® Cmcre!e •�;�� EXISTENCE OF ANY EASEMENTS.COVENANTS.RESTRICTIONS OR RIGHT-OF-WAY Overhang CHECKED BY: SG GRID: 2224 TAKINGS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT.UNDER NO FENCE —X—X—. , CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION,FOR ORDERED BY: ROB CAMPBELL w/ARM SERVICES SCALE: 1"=20' REF:13L173 FB:68115 ��//MAood Oeck ESTABLISHING PROPERTY LINES.OR FOR PLOT-PLAN PURPOSES.