ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP201510
PID Number: 011-132-27
Dwelling: ON Single Family (SF)
❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New K Upgrade
Name
Andrew and Nida Velson
ABSORPTION FIELD
❑ Deep Trench 0 Wide Trench ❑ Bed ❑ Mound
Site Address
8333 Wilcox Street
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
3
1.2 GPD/SFJ
10.0 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
6.0 Ft.
Gravel depth beneath pipe
4.0 Ft.
Subdivision
Block Lot
Sand Lake #2
7 10
Fill added above original grade
0 Ft.
Gravel length
40.0 Ft.
Township Range Section
Gravel width
5.0 Ft.
Beds: Number of Lines
NA
Distance between lines
NA Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
400 FF
1
NA Ft.
Well
Exist
79.6*
NA
NA
25'+
TANK 0 Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Existing
Capacity
Gal.
Surface Water
Exist
100'+
NA
NA
Material
Number of compartments
Lot Line
Exist
5.0
NA
I NA
NA
Foundation
Exust
10'+
NA
NA
LIFT STATION
Manufacturer
Capacity
Remarks *See plan sheet for well separation to all wells
Gal.
in area.
Alarm location
Electrical installed by
Installer
PIPE MATERIAL House to tank Tank to 3034
drainfield
GLW
Drainfield 3034 CO/MT3034
inspector Pannone Engineering
BENCH MARK (Assumed elevation) 100.0 ft
Inspdection im 2/15/22 n 2/16/22
Location and description
2
3`" 2/17/22
4th
Top of Double Clean Out Stand Pipe
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
Conditional Approval:
Date
OF. A/q �
Q
.' 9TH
.�... ... ..'.........
Steven R� Pannore
Septic Syste
p:. �F 81
��✓;¢
A ro ��
pp
Date
� ��•....• ���.�
Note: this approval does not include well permit requirements.
kI\GV VJIVG/ 1 V)
TH-1978
(CUTLER ENGINEERING)
i
TH-1978 �
(CUTLER ENGINEERING)—
'
WELL (E)
SEPTIC AREA (E) /
98.7
i
WELL (E) 2j 3; NEW DRAIN FIELD
40LF x 5'W x 4.0'ED x 10.0'TD
INSTALLED CO AND MT AT EACH END
INSTALLED MT IN OUTSIDE CORNER AT BEND
72.8 M2 INSTALLED DIVERTER VALVE AFTER DCO
M3
A LOT 10 C2 \�
0 1N1.0 SEP AREA (E)
3 BR LAJ / \\ -29.1
HOUSE � i
(E) mi * -I I I_
79.0 0t ?� TH-1982
PERC TEST (SELLENS)
B o 0
85.4 Dv N
----
DECK I
WELL (E) /
vV--___,__ SEPTIC AREA (E)
W
O
DESIGN PARAMETERS
UPGRADE SEPTIC SYSTEM
NO. BEDROOM: 3(450 gpd) /
TANK SIZE: 1000g /
PERC RATE: <1 MPI 12
SOIL RATING
. 1.2 GPD/SF
AREA RQD: 375 SF
A
TYPE: WIDE TRENCH 4'ED
DV
—SYS.
RF: 0.50
61.2
MIN LENGTH: 37.5 LF
W
47.3
M1
USED:
48.7
40LFx5'Wx4.0' E.D., 10.0' TD
w
TOTAL AREA: 400 SF
C2
NOTES: PAMONE ENG SVC, C, LLC
RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
DRAWN BY:
� DRM
SAND LAKE #2, BLOCK 7, LOT 10
ANDREW AND NIDA NELSON
8333 WILCOX STREET
PLAN ANCHORAGE, AK 99502
SEPTIC AREA (E)
TH-1980
GLI (BARNARD)
TH-1980 \ x n
(BARNARD)
z�
� U
N
A
B
DV
70.3
61.2
Cl
54.9
47.3
M1
56.1
48.7
M2
49.7
63.3
C2
33.6
51.1
M3
33.7
51.7
NOTES: PAMONE ENG SVC, C, LLC
RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
DRAWN BY:
� DRM
SAND LAKE #2, BLOCK 7, LOT 10
ANDREW AND NIDA NELSON
8333 WILCOX STREET
PLAN ANCHORAGE, AK 99502
SEPTIC AREA (E)
TH-1980
GLI (BARNARD)
TH-1980 \ x n
(BARNARD)
z�
� U
N
01 A
Dote
03/04/2022
,q
9
Scale
1"-30'
. NO
011-132-27
Steven R. Pon none
PERMIT N0.
�F CE 8149®®
� .... • P�E'�
OSP201510
Sheet
k� PROFESS O� ®.
2 OF 3
READING
1
CLOCK
DATE TIME
211+,. � ��, 8:40.
W
WATER
LEVEL
READING
2.11
NET DROP
---
2
8:45
5 MIN
8.11
>
m
j
m
_
m
F- Z,
2.11
---
4
W
0 O
Z0O
K
X0
Z
5
8:51
100.0(BM)
of
>
c
o
oz
FO
o j
6 MIN
8.11
1
7
8:57
__-
2.11
---
8
9:03:30
6.5 MIN
-99.8-
9.8O
9
9:04
--_
2.11
-_-
10
9:11
7 MIN
0
1.2
11
9:11
---
2.11
-_-
SW/
9:18:15
7.25 MIN
8.11
1.2
13
9:19
SM
2.11
EXISTING
1000g
14
93.80
7.3 MIN
x-93.8
1.2
15
SEPTIC TANK
---
2.11
---
16
9:34:25
7.4 MIN
8.11
1.2
89.8-
9:35
\ `-89.8
89.8
___
18
9:42:19
7.3 MIN
8.11
1.2
GW
<83.8
PROFILE
READING
1
CLOCK
DATE TIME
211+,. � ��, 8:40.
-
NET TIME
---
WATER
LEVEL
READING
2.11
NET DROP
---
2
8:45
5 MIN
8.11
0.8
3
8:45
---
2.11
---
4
8:50:45
5.75 MIN
8.11
1
5
8:51
--
2.11
6
8:57
6 MIN
8.11
1
7
8:57
__-
2.11
---
8
9:03:30
6.5 MIN
8.11
1.1
9
9:04
--_
2.11
-_-
10
9:11
7 MIN
8.11
1.2
11
9:11
---
2.11
-_-
12
9:18:15
7.25 MIN
8.11
1.2
13
9:19
---
2.11
---
14
9:26:20
7.3 MIN
8.11
1.2
15
9:27
---
2.11
---
16
9:34:25
7.4 MIN
8.11
1.2
17
9:35
--
2.11
___
18
9:42:19
7.3 MIN
8.11
1.2
PEROLATION RATE -1.2 (min/inch) PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 4 FT AND 5 FT
RECORD DRAWING PA NONE ENGS SVC, LLC � ��OF q���r� Date
P.O. BOX 100217 ANCHORAGE, AK 99510�� qs��� 03/04/2022
DRAWN BY: PHONE (907) 272-8218 FAX (907) 272-8211,�Q . Scale
DRMSAND LAKE 2, BLOCK 7, LOT 10 .' • •' P11-
® ..., 011-132-2-
27
ANDREW AND NIDA NELSON Steven R. Pannone PERMIT N0.
8333 WILCOX STREET �� CE 8149���� osP201510
PLAN ANCHORAGE, AK 99502 sheet
��®F�OFESSION��® 2 of 2
0
CD
0 C:
0
woo Z
0
> —4 0
0
02, oi >
CD
0
x
0
o
-)0-3
<
'Mir 0
00
0
>
0
CL
0 0—t.
<
L
< 0
cr
CD 0 ID ID
tn
44
m
z
z
0 M
CD0
=
6=
-n
>
c
cry2)
D
(D 0
(D
OZ
CL
3
CD
w <
=
(D -0 CD (D CL z
n CO�
;—T
0
60
0
rp "o
o �o w
>
z
to
CL 0
(n
0 0
0- 0
0 0
W CD
cr
0- mcn
Z
C)
M
CO
W
N)
CL CD
-0 8
CDM
>
(D
> (a
rn
rn
(j)
w
0 W
CL
o
cn (r
cr" -0-0
2L
0
M
toria
c
-0 CO
cn (D
CPO in
(c
m°
m
>
ar (n
cum'CO
<
( D
0
—z
C:
3 9
(D
0
(D 0
<.p
>
CD
to
o
U)
zr
-0
E c
CD
0
r
--I
N
cr 0ca
ccs
0 (D 00
m.m
0 0
U)
—0
w
M (a
tQ
(n 0
0 0
0 , —
CD 0 W <z
0) CD
3
-.j A
0 CD
CL
CD 0 co to
0
4 = c
0
a
0
cn (D 0
IM
m
0
0 C:!�
0
0
— ocsca
0
0 (o (r
cn
En 0
0
0 -5.
>
CD
0
(n
>
p. o o 0-
o2
OD
0
0
(D ei0
-0
(D
0.0
CD —8
N CD
< 0
=
to =
CD
@ I...,
CD
< 3
p,
co
(D 0
0
m
NO
r1l)
JU
a
C)
0
CD
0 C:
0
woo Z
0
-0
02, oi >
0
n
�p -4 -4 >
tD
0 jeom
'Mir 0
00
0
>
rq.
CL
m
44
MUNICIPALITY OF ANCHORAGE
Community Development Department _ .. Phone. 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 011-132-27
Property owner(s) Andrew & Nida Nelson
Mailing address 8333 Wilcox Street, Anchorage, AK 99502
Site address 8333 Wilcox Street
Day phone
Legal description (Sub'd., Block & Lot) Sand Lake #2, Block 7, Lot 10
Legal description (Township, Range & Section)
Lot Size 6,750 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR:
APPLICATION IS AN: TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑x
Initial ❑ Single Family (SF) ❑X
Septic Tank
❑
(w/wo AD U)
Upgrade
Holding Tank
ElRenewal
Duplex (D) ❑
Privy
❑
Multiple Dwellings ❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance.
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: (`{ S Waiver Fees:
Date of Payment: Date of Payment:
Receipt Number: Receipt Number:
Permit No. Q S P,� a 1 d a Waiver No.
Permit App__- : .:..,.c
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@panenaak.com
DATE 2/10/22
Subject: Expired On -Site Water and Wastewater Permit
Permit Renewal Request
Permit Number: OSP201510
Legal Description: _S t Lake #2 137 L10
sed
This is a request to renew the permit for the above mentioned lot. All site conditions remain the same.
The construction still will not affect the health, safety, or development of the surrounding lots.
Sincerely,
a
Steven R. Pannone, PE, F. ASCE
Owner/Civil Engineer
Mailing: P.O. Box 1807, Pah-ner, AK' 99045-1807
Telephone: (907) 745-8200 FA,;: (907) 745-8201
MUNICIPALITY OFANCHORAGE
On -Site Water & Wastewater Program
POBox 1S685O 470VElmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax; (907) 343-7997
PonnitNunmbnr {}SP201510
Work Type: Septic Upgrade
Tax Code Number: 01113227000
Site Legal Address: SAND LAKE #2BLR 7 L 10 G:2224
Site Mailing Address: 8333WILCOX ST, Anchorage
Owner: NELSON ANDREW SIR &NIDA
Design Engineer: PANNONEENGINEERING SERVICES
This permit is for the construction of:
Effective Date:
Expiration Data:
Lot Size in Sq Ft
1/7/2021
1/7/2O22
6750
2 Disposal Field E3 Septic Tank El Holding Tank 0 Privy F1 Private Well 0 Water Storage
All construction shall bainaccordance with:
1. The attached approved
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (19AAC80)
3, The wastewater code requires inspections during the installation. The engineershall notify the Development
Services Department per AMC 1S.G5.Provide notification bvcalling (GO7)343-79O4(24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall beeither:
o. Opened and Closed onthe same day, or
b. Covered, sealed, and heated toprevent freezing
Special Provisions: A confirmation percolation test shall be completed at time of construction to confirm
application rate for accepting soU. If results require a design change, construction shall stop pending review and
approval ofachange order. Please submit results vvithLheinspection report (or change order, ifrequinad).
Received By: 4Lv Date:
Issued By: f6jX61(Lk Date:
3
Municipality of Anchorage
P.O. Box 196650 a 4700 Elmore Road
Anchorage, Alaska 99519-6650 a (907) 343-7904 a Fax (907) 343-7997Alaska 99519-6650 a (907) 343-7904 a Fax (907) 343-7997
http://www.muni.org/Onsite
Development Services Development Services Department
On -Site Water and Wastewater Section
1-
1)ep:n-tmcnt
* * * * VARIANCE/WAIVER REVIEW * * * *
Waiver#: OSV211002 COSA#: Permit#:OSP201510
PID#: 011-132-27
Legal Description: Sand Lake #2 Block 7 Lot 10
Engineer: Pannone Engineering
Applicant: Andrew & Nida Nelson
Your request for a waiver of the required 10 feet horizontal separation from the absorption field
to the property line has been approved. The approved separation distance is 5.0 feet. In addition,
your request for a waiver of the required 100 feet horizontal separation from the absorption field
to nearby private wells has been approved. The approved separation distances are as follows:
To the well on Sand Lake #2 B7 L8 - 98 ft
To the wells on Sand Lake #2 B7 L9 and L10 - 70 ft
To the well on Sand Lake #2 B7 L11 - 80 ft
See engineer's waiver request for justifications.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the
on-site wastewater disposal system will require all separation distances be met or another
approval from this department.
■ ... t ........ t t t t. t .. t■■ .. t. t. t a M 0 M M M. t. t.\ ... M ...... 0 M M x M M ... t. t t .......... ■ 1
Waiver is Granted: X Waiver is not Granted:
r� f�j &AXB
Date: � 1I.Q 0 a Approved by: �
Name of Reviewer
**** VARIAN C E/WAIVER REVIEW ****
MUNIMPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWERIWELL PERMIT APPLICATION
Parcel I.D. 011-132-27
Property owner(s) Andrew & Nida Nelson
Mailing address 8333 Wilcox Street, Anchorage, AK 99502
Site address 8333 Wilcox Street
Day phone
Legal description (Sub'd., Block & Lot) Sand Lake #2, Block 7, Lot 10
Legal description (Township, Range & Section)
Lot Size 6,750 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑X
Initial ❑
Single Family (SF) ❑X
ADU)
Septic Tank
❑
Upgrade FX(w/wo
Duplex (D) ❑
Holding Tank
❑
Renewal ❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Septic to existing well
iC 4-o �oA U
Distance: 5
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
ignature of property owner or authorized agent)
Permit/Rush Fees: 5l a Ulla
Date of Payment: IQ IQ S / a0 �2 O
Receipt Number: 0a 13 2 G
Permit No.
Permit App__- :• ::_. c
Waiver Fees: 4 11
Date of Payment: IC, �
Receipt Number: 099 � 1 G
Waiver No. D'y H 00
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201510, Rebecca Carroll, 01/07/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201510, Rebecca Carroll, 01/07/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201510, Rebecca Carroll, 01/07/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201510, Rebecca Carroll, 01/07/21
icy
;mi�f �R,q
a mm
ago
1 Q
I t s
(/t
r+
,
WIL COX STREET
ED
fi 1� 0 1
z : -n
OWN,
u
N 00 02'33" F 5000
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program, 4700 BragawSt.
P.O. Box 196650 Anchorage. AK 995IM50 Page of
www.cl.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM ANDIOR WELL INSPECTION REPORT
Permit Number. SWO80103 PID Number. 011-132-27
Natrm Andrew and Nida Nelson
Wastewater System: []New E] Upgrade
Ad�:
8333 Wilcox Street Anchorage, AK 99502
ABSORPTION FIELD
Ph" 248-7556 N�tw d 13�- 3
ODWT-0 0SWImToo 13OW OM� 0 Otmr
LEGAL DESCRIPTION
Soi Rxwq Existing
Twit Dapin itw,, ",,iii wwo,
GPDVe
Smi, 7 LM 10 Sand Lake No. 2
DWM w im tx,tx,,, ongw w9m:
G� mpm � pm.
Ft.
Ft
T.wrwM s�
FM OV" Wtxie:
G� LOW
Ft.
Well: [I New Upgrade
D� .1�
Ft.
FL
c� 8. c). -IT"O"M
---JC�w
T" Wi,.ptm imii:
P" Mtmntti�
Existing
R
F,
Fe,
lime 0011�1.
suft wow
in",w.
Dim
I FL
John's Excavating
7/212008
Y�
P� SON
c"ng �gm � d�
TANK
GPII
F1.1
FL
SEPARATION DISTANCES
91 Septic [I Holding 0 S.T.E.P. 0 Other.
To
Septic
Absorption
Lin
Holding
lublit,?rNate
lit��
ty
Frtwt '--�
Tank
Field
Station
Tank
Sotwor Um
Anchorage Tank
11,000 G&
1018�,
� a
w"
85--
'100.
N/A
N/A
>26
Fiberglass
TWO
sw"wmw
>100,
>100'
NIA
N/A
LIFT STATION
wum
�6
>10'
NIA
N/A
P� W. � a
-Punv w � a
Hio walff a
F�w
g
>10'
N/A
N/A
it,
in
in
E� lrwip� m!a 117
None
Noted
See Waiver From Wells to Septic Tank.
t BENCH MARK
6i','Midway.l;�
Back Deck - North
A�r
100 FL
M. Anderson
Inspections performed by: Dates: 19 thnO08,
0 F A4 lip
2nd 7r2/2o08
Development Services Department Appro;a—I
49M
Conditional Approval Date:
0 .. ....
.... ... . .. ......... ..
14CHAA L ANMSON
4381
Reviewed and appro Date:
ved b/y-
S;
44 3 �. Q&
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
MEMORANDUM
DATE: September 4, 2008
TO: Jeff Poet
FROM: Mike Anderson, P.E.
SUBJECT: Lot 10, Block 7, Sand Lake Subdivision No. 2
Permit No. SWO80103
The well seal has been changed to a new sanitary seal on the subject lot. The as built
for the new septic system can now be approved.
CL
CL
CL
c
Li
0 PCI
r� m cd
z
LU
C� C/)
0
0 0 <
0 < — C) m 0
MCL U) 0 0 we
2 LU -j m u
0020 1 E m
> wo
E M om
C LLI �2 w z
< < z <
E - U�) m
m -@ =) 0
U) 15 10 U) 0
.EL 06 0
.2 z umn EL
CLU Cc I
= mi -t - LLJ 0
me L)
_j G =
Mo
,u
> R Br Zz G
LU uj
X
Ln
05
�o <
V)
00,0(;
KA)
i T I
0
0
U)
0
z
4@@Jls X001!m
Mt
level%
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-79D4
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number: SWO80103
Existing &
FFinished Grade
97.
U1,000 Gallon
Septic Tank
9245
. Y/
Page 3 of 3
PID No. 011-132-27
Tank &2Post Tank �Cleanouts Placed Under This Permit.
Existing Tank'Pumped, Crushed and Removed.
PROFILE AS -BUILT
No Scole
MUNICIPALITY OFANCHORAGE
Development Services Department
On -Site Water& Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 995M6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Jul 01, 2008
Expiration Date: Jul 01, 2009
Permit Number: SWO80103 Parcel ID: 011-132-27
Legal Description: SAND LAKE #2 BLK 7 ILT 10
Design Engineer: 0014 ANDERSON ENGINEERING Site Address: 008333 WILCOX ST
Owner Name: ANDREW & NIDA NELSON Lot Size: 6750 SO. Fr.
Owner Address: 8333 WILCOX STREET Total Bedrooms: 3 Permit Bedrooms: 3
ANCHORAGE, AK 99502 -
This permit Is for the construction of:
F� Disposal Field [?] Septic Tank Holding Tank Ej Privy E] Private Well Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907)343-7904(24 hours). (Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed. and heated to prevent freezing.
711log lot -to I'v 14�,W-Iovlll mn4l / Ive 11 Cop
Received By:
Issued By:
Date: 7 1. oi�
Date: 7111-79
e,
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Sitc Water and Wastewater Progmm
4700 Bragaw Street
P.O. Box 196650 Anchoragc, AK 99519-6650
wwv.ci.anchoragc.ak.us
(907) 343-7904
Waiver Review Workshect
WR#: 080040 PID#: 0 11-132-27 HA/Permit# SW080103
Date Received: July 1, 2008
Legal Description: Sand Lake N2, Block 7 Lot 10
Engineer
Michael E. Anderson
Anderson Engineering
P.O. Box 240773
Anchoragge, AK 99524
Applicant: Andrew and Kida Nelson
Waiver Requested: 85' and 90'frorn tank to two different wells
Criteria: Geology
A. Water Table
B. Soil Sorption
C. Permeability
D. Water Table Gradient
E. Horizontal Separation
Total:
Points:
ZD
40 .... @sees@ .... season@ .... .... Owosso ..... Swansea ... a
Waiver Is Granted: X
List Conditions or Reasons for above:
Waiver Is not Granted.,
Date: 711/08 By: Deb Wockenfuss
Name of Reviewer
somesson .... @@@@@seen ..... @Osseo ... soness ... goes.
Rec#: 57630 Amount: $22-0_ Date Paid: 7/1t2008
Municipality of Anchorage
P0. 14a 196CM - Anchnmgc, AlasVit M519 -G;54) - 47M 11niom Mmul
N, Offim(907013-WI
Mayor Mark Begich Development Scrvices Del),urtnient
July 1, 2008
Michael E. Anderson
Anderson Engineering
P.O. Box 240773
Anchorage, AK 99524
Subject: Waiver Request for Sand Lake #2, Block 7 Lot 10
Waiver Request WRM 080040
Parcel ID # 0 11-132-27
SW080103
Dear Michael E. Anderson:
M-ij -ILA
ent
Your request for a waiver of the required 100 feet horizontal separation from the
septic tank to the private well has been approved. The approved separation distance is
85 feet from the well on Lot I I and 90 feet from the well on lot 10.
This waiver approval applies to the existing septic tank to private well separation only.
Any future upgrade to the on-site wastewater disposal system will require all separation
distances be met or another approval from this department.
If there are any further concerns or questions regarding this waiver, please call our office
at 343-7904.
Sincerely,
�ck
Deb Wockcnfa
Civil Engineer
On -Site Water & Wastewater Program
Community, Security, Prosperity
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
www.muni.org/onsite
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 011-132-27
Property owner(s) Andrew and Nida Nelson Day phone 248-7556
Mailing
8333 Wilcox Street Anchorage, AK
Code 99502
12-3-5.5
Site address 8=0 Wilcox Street Anchorage, AK —Zip Code 99502
Legal description (Sub'd., Block & Lot) Lot 10, Block 7, Sand Lake Subdivision No. 2
Legal description (Township, Range & Section)
Lot Size 6.750 Sq. Ft.
THIS APPLICATION IS FOR IS all that apply):
Absorption Field El
Septic Tank
El
Holding Tank
El
Privy
El
Private Well
Water Storage
D
Number of Bedrooms Three (3)
THIS APPLICATION IS AN:
Initial
11
Upgrade
El
Renewal
El
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
vlu" E&Len
(Signature of property owner or authorized agent)
Receipt Number. Receipt Number. 'rj-4 (P
(Rev. 11/05)
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE,. AK 99524
S22-7773 S22-6779 (FAX)
June 4, 2008
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 10, Block 7, Sand Lake Subdivision No. 2
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The septic tank on Lot 10, Block 7, Sand Lake Subdivision No. 2 is failing and must be
replaced. We are proposing to replace the tank with a new 1,000 -gallon fiberglass tank
to serve the three-bedroom home on the lot. We are therefore requesting a permit be
issued for the construction of a new septic tank to serve the home. The attached Site
Plan and backup documentation identify the location and configuration of the existing
septic system and the location of the new tank. Also identified on the plans is the
existing well on the lot. The new tank will be placed as far as possible from the well, but
is still only 85' away. It will also be located approximately 90' from the well on Lot 11 to
the south. A request for a waiver of the separation distance is attached to this permit
application. The existing tank on the lot will be properly disposed on the property or
removed from site. The drainage patterns will be maintained after construction.
The ground surface on the lot slopes at shallow grades to the east. The new septic
tank will be constructed near the location of the existing tank and as parallel with the
slope of the land as possible in conformance with Municipal requirements.
If the tank is constructed in accordance with our design the following statements apply:
I . The tank, if constructed as designed, will have no adverse impact on the wells in
the area or those to be constructed in the future.
2. The tank, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
Lot 10, Block 7, Sand Lake No. 2
June 4, 2008
Page 2 of 2
3. The tank, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The tank, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
I,OJ,J E 044---'n
Michael E. Anderson, P.E.
Attachments
35.00
L z 16
C'
10
Q)
C C:.. C W-11
Lo Xo�R d,.M..OW
Exist ng, 1009 1 SYV��.
Well V)
Lmsting
well 0
0 0
L) 14 Existing 01
Well 0 -a
3: 1 c
Existing LIJ
,ng
Well
12
............
7
49th 'o
. ..... ....... ... . ..... ....
. . . A .......
MICHAEL C ANDERSON
'N AREA MAP
% . "t
1. No. CE -4381
As
JOG,,
% I I%k Isk Isk
wilt%
Am Wilcox Street
*.rn%
50.00
U)
:EX
M
0 40 >
0 m
0
0
0 C
oft CD
r) 3
FZD
CD
rl
C) 0 <
0
3 0 C/)
- 0
3
0 0 Z
0
0
no
'0
5
0
0
CD!t
ry
1,000 GALLON
FIBERGLASS SEPTIC TANK
STANDARD
I
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 10, BLOCK 7, SAND LAKE SUBDIVISION NO. 2
GENERAL:
The scope of this project includes the pumping and removal of the existing
septic tank on the property and the procurement and placement of a new
1,000 -gallon septic tank at the location shown on the Site Plan. Work also
includes the verification and replacement, if necessary, of a foundation
cleanout, placement of two post tank cleanouts and tieing the new tank into
the existing absorption trench. The new septic tank must be placed as far as
possible from the existing well on the lot and 90' from the private well on Lot
11 to the south. It must also be placed 100' from any surface water in the
area and 10' from the water service line from the well. A minimum of 4' of
cover is required over the septic tank. The foundation cleanout must be
replaced if one is not found on the property.
2. Construction shall be in accordance with the approved site plan, design
drawings, Municipal Permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
3. The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the location
of all lot lines. The Contractor must also verify the location of wells in the
area and assure that the separation distances are met.
4. Unless specifically agreed otherwise, the contractor shall be responsible for
final grading areas subsequently depressed from soil settling. Property
owner shall be responsible for revegetation of affected areas unless
specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified by the
Municipal Development Services Department Building Safety Division On -Site
Water and Wastewater Program for system installations. Owners installing
their own systems must receive prior approval from the On -Site Water and
Wastewater Program before beginning system installation.
SEPTIC TANK INSTALLATION
1. A new fiberglass 1,000 -gallon septic tank must be procured from Anchorage
Tank & Welding. The specifications for the tank and the installation
instructions are attached and must be closely followed.
Lot 10, Block 7, Sand Lake No. 2
June 4, 2008
Page 2 of 3
2. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
3. The septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches above
final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial
insulation.
6. A foundation cleanout shall be installed one to four feet from the building
foundation. Two cleanouts are required between the tank and the drainfield.
7. Final grading over the tank shall be such that a positive slope exists away
from the septic tank.
DRAINFIELD CONSTRUCTION: - EXISTING ABSORPTION TRENCH TO REMAIN IN
SERVICE
1. The drainfield shall be constructed to the dimensions shown on the design.
The bottom of the trench shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a level
bed of drainfield rock. Rock should then be placed over the pipe to provide a
minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield rock
and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations shown on
the design. The portion below ground must be perforated.
5. Contractor shall verify the septic tank and drainfield are a minimum 100' away
from any private water wells in the area, 150' from a Class "C" Well or 200'
from any community well.
6. Direct bury insulation must be placed over the distribution system if less than
3' of backfill depth is available. Finish grade over the trench must be
mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
Lot 10, Block 7, Sand Lake No. 2
June 4, 2008
Page 3 of 3
8. A minimum 2' of accepting soil is required below the drainfield rock for a 5'
wide trench. All pockets of unacceptable materials must be removed and
replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic tank
manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and
solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662
or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow
Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Femco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the
#200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These inspections
must be conducted under the supervision of a professional engineer registered
in the State of Alaska. The first inspection must be conducted after the
excavation of trenches, beds or pits and before the installation of any gravel. A
septic tank may be set in place, but may not be backfilled.
The second inspection must be conducted after the placement of the geotextile
fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No
backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction notes
for use in preparing the certified as -built of the completed system.
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 �677-7766 (FAX)
MEMORANDUM
DATE: June 26,2008
TO: Deb Wockenfuss
FROM: Mike Anderson, P.E.
SUBJECT: Lot 10, Block 7, Sand Lake Subdivision No. 2
Septic System Permit Upgrade Permit
Attached are the water sample results for the well on Lot 10 and the adjacent well on
Lot 11. No coliform or appreciable nitrate content was noted in the water. The wells
are therefore not influenced by the present location of the septic tank. The proposed
location is more than 30' further from the wells and will have even less effect on the
water quality. The separation waivers allowing the septic tank to encroach in the
protective radii are justified.
I have also moved the septic tank to 5' from the existing absorption trench. Please
advise if additional information is required.
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
June 5, 2008
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject: Lot 10, Block 7, Sand Lake Subdivision No. 2
Separation Distance Waiver
Well to Septic Tank
Dear On Site Services Engineer:
The septic tank on Lot 10, Block 7, Sand Lake Subdivision No. 2 has collapsed and
must be replaced. The existing tank was originally constructed in July of 1978 at a
distance of 51' from the well which did not meet setback requirements at the time. A
waiver request was found in the Municipal file requesting the separation distance be
reduced to 51'. No approval of the waiver request was found.
The individual lots in the Sand Lake No. 2 Subdivision are typically 50' wide and 135'
long. It is nearly impossible to place a well and septic system on each lot and meet the
required setbacks. Waivers have been issued throughout the subdivision allowing
septic systems to encroach within the protective well radii. The separation distances
between Class C Wells and septic systems are routinely waived to 100'. The existing
Class C Well just east of this property on Lot 15 was waived to 100' in 1982.
We have relocated the septic tank as far from the existing well on the property as
possible to approximately 85'. It is also approximately 90'frorn the well on Lot 11 to the
south and 100' from Lot 9 to the north. We are also proposing to place a fiberglass "life
time tank" in lieu of the standard steel septic tank to reduce the possibility of effluent
leakage. All connections to the new tank will be carefully inspected and approved to
insure water tight seals. The existing septic tank will be pumped and properly disposed.
The placement of the new septic tank in the location proposed will add over 30'
separation from the wells in the area from the previous location. The additional
distance along with the type of tank and the watertight connections will increase the
protection to the wells from contamination. It is not possible to get the full 100'
separation due to the limited surface area of the lot and the placement of the wells in
the area. We therefore recommend the distance between the well on this lot and the
Lot 10, Block 7, Sand Lake No. 2
June 5, 2008
Page Two
new septic tank be waived to 85'. We also recommend the distance to the well on Lot
11 be waived tog 0'.
Sincerely,
Michael E. Anderson, P.E.
Attachments
V � W, F A%�,f SCN
Waiver WROS0040 SWO80103
Sand Lak(
B2 L14
255
257
Water Table Gradient Calculation
Sand Lake #2, Block 2 Lot 10
227'
7/l/08
Sand Lake #2,
I ETPIN m lri�
01
;6'
Sand Lake #2, B7 Ll 0
Parcel ID: 011-132-27
Waiver for 85 feet from tank to well
Issued July 1, 2008
General
1. From the water sample, total coliform was 0, and total nitrates was 0 mg1L. New tank will
be 30' farther away from the well.
2. Any overflowing sewage would move away from the well head.
ADEC Criteria Points
Water Table
Depth of water bearing zone in well 236 feet
Assumed bottom of field 8 feet
feet
1'(1361190) + 7 7.7
Soil Sorption
Soil descriptions
Permeabili
Soil descriptions
DEC PTS Depth From
Depth To
Thickness
Calc. Pis
Sand
1.5 8
12
4
0.03
Sand and Gravel
1 12
61
49
0.21
Sand
1.5 61
218
157
1.03
clay and sand
4.5 218
236
18
0.36
0
0.00
0
0.00
228
1.63 1.6
Permeabili
Soil descriptions
Water Table Gradient -
Water table slopes away from the water source 5.8
Assume +9.4% slope
Horizontal Separation
85 feet between septic tank and well
x = 10/25 + 2.0 2.4
Total Points 19.1
As per ADEC waiver guidelines, with a point value of 19.1. almost sure to be free from any form of
contamination from household sewage.
DEC PTS Depth From
Depth To
Thickness
Calc. Pis
Sand
1.5 8
12
4
0.03
Sand and Gravel
1 12
61
49
0.21
Sand
1.5 61
218
157
1.03
clay and sand
3 218
236
18
0.24
0
0.00
0
0.00
0
0.00
08
1.51 1.5
Water Table Gradient -
Water table slopes away from the water source 5.8
Assume +9.4% slope
Horizontal Separation
85 feet between septic tank and well
x = 10/25 + 2.0 2.4
Total Points 19.1
As per ADEC waiver guidelines, with a point value of 19.1. almost sure to be free from any form of
contamination from household sewage.
Sand Lake #2, B7 Ll 0
Parcel ID: 011-132-27
Waiver for 90 feet from tank on Lot 10 to well on Lot 11
Issued July 1, 2008
General
1. From the water sample, total coliform was 0, and total nitrates was 0 mg[L. New tank will be
30'farther away from the well.
2. Any overflowing sewage would move away from the well head.
ADEC Criteria Points
Water Table
Depth of water bearing zone in well 180 feet
Assumed bottom of field 8 feet
feet
1-(80/190) + 7 7.4
Soil Sorption
Depth To
Thickness
Calc. Pis
Soil descriptions from well log of Lot 11
Sand and Gravel 1 8
35
27
DEC PTS Depth From
Depth To
Thickness
Calc. Pis
Sand and Gravel 1 8
35
27
0.16
Sand and Gravel 1 35
60
25
0.15
sand and silt 3 60
100
40
0.70
clay and rocks 5 100
180
80
2.33
0.00
0
0.00
0
0.00
0
0.00
0
172
3.33 3.3
Permeabili
Soil descriptions from well log of Lot 11
DEC PTS Depth From
Depth To
Thickness
Calc. Pis
Sand and Gravel 1 8
35
27
0.16
Sand and Gravel 1 35
60
25
0.15
sand and silt 2 60
100
40
0.47
clay and rocks 3 100
180
80
1.40
0
0.00
0
0.00
0
0.00
-i-72-
2.16
2.2
Water Table Gradient -
Water table slopes away form the water source
5.8
Assume +9.4% slope
Horizontal Separation
90 feet between septic tank and well
x = 15/25 + 2.0
2.6
Total Points
21.3
As per ADEC waiver guidelines, with a point value of 21.3, almost sure to be free from any form of contamination
from household sewage.
Li
IN.
YC
141 1
ZVP
A
SGS RCEN
1082667001
Client Name
Anderson Engineering
Project NameIN
Wilcox
Client Sample ID
8341 Wilcox Lot I I
Matrix
Drinking Water
IMISID
0
Sample Remarks
All Dates/Times are Alaska Standard Time
Printed Date/Time
06/23r-008 16:21
Collected Datefrime
06/lOP-008 13:40
Received Daterrime
06/10P-008 13:50
Technical Director
Stephen C. Ede
Allowable Prep Amlysis
ll=mctcr R�utts Pot. Units Method Container ID Limits Date Date Init
Metals by ICP/M5
Arsenic 28.0 5.00
Waters Department
Total Nitmte/Nitritc-N ND 0.100
microbiology Laboratory
Colony Count 0
Total Coliform 0
recal Coliform 0
ugIL
EP200.8
C
(<10)
06/17/08 06/19/08
NPB
mgfL
Sh,120 450ONO3-F
B
(<10)
06120/08
JDZ
coVlOOmL SM209222B
coVIOOmL SN1209222B
col/100mL SN120922-IB
A (<200)
A (< 1)
A (<I)
06110/08 DSH
06110/08 DS11
06110/08 DSII
A
SGS Ref.N
1082667002
Client Name
Anderson Engineering
Project N2MCIN
Wilcox
Client Sample 11)
8333 Wilcox Lot 10
Slatrix
Drinking Water
P%%'SlD
0
Sample Remarks:
parameter Resulm Poll
metals by ICP/MS
Arsenic 24.5 5.00
Waters Department
Total NitnucNitritc-N ND 0.100
MicrobioloW Laboratory
Colony Count 0
1 otal Coliform 0
Fccal Coliform 0
All DalestTimes are Ata%ka Standard Time
Printed Daterrime
06/230-008 16:21
Collected DatelTime
06/lOP-008 13:30
Received Daterrime
0611012008 13:50
Technical Director
Stephen C. Ede
Allomuble Prep Analysis
Uniu Method Comamer 10 Limits Date Date [nit
ugfL
EP200.8
C
(<10)
06117/08 06119/08
NRB
mg/L
SNUO 45GONO3-r
B
(<10)
06120/08
JDZ
cot/lOOmL S%U09222B
coVlOOmL SN1209222B
col/100ml. SX1209222B
A (<200)
A (<I)
A (<])
06110/08 DSII
06/10/08 DSII
06/10/08 DSII
I
I
LOT 18
(VACANTJ ------------------
------------
W. 84th "I—
VACANTLAND
-------------------------
49
0*: LOT 15. BLK. 7, SAND LAKE SID #2
0 .. .............. 0 .......
WELLAND SEPTIC SYSTEM
... ..... ......
0 SITE PLAN
�o THECOOREF.MWAL a
41 % CE -3589 as
vo a., .a AV FLATTOP TECUMCAL SERVICES I INCH 50 FEET
roi oases IV
k1k 4offe Sig Vv 14530 ECHO STREET DRAWN BY TFM
I%Ak ANCHORAGE, ALASKA 99516 AUGUST, 1998
NOTE: THIS IS NOT A SURVEYED PLAT.
LOTS
ALDER
PARK ISM
SYST.
W. 84th "I—
VACANTLAND
-------------------------
49
0*: LOT 15. BLK. 7, SAND LAKE SID #2
0 .. .............. 0 .......
WELLAND SEPTIC SYSTEM
... ..... ......
0 SITE PLAN
�o THECOOREF.MWAL a
41 % CE -3589 as
vo a., .a AV FLATTOP TECUMCAL SERVICES I INCH 50 FEET
roi oases IV
k1k 4offe Sig Vv 14530 ECHO STREET DRAWN BY TFM
I%Ak ANCHORAGE, ALASKA 99516 AUGUST, 1998
NOTE: THIS IS NOT A SURVEYED PLAT.
r
7
OF A4
......................
.71490002C F. MOORE
CE -3589 4p
kat?z1v V
I
L'o 7' 16'
56 -C
go!
to
1447c4SC
rsr.
ly e
lzro
tax
1"4,5x
Aftn 0
U,0
V
PV
semc
t -o
r
OF A4
......................
.71490002C F. MOORE
CE -3589 4p
kat?z1v V
fA
L 7, -SAND t.Akf� 2 SID
W61�1� SC -PVC -StSr"EMS
TE PI-Aff.
SCAWF:
0.4r9V
C) WN 0 P:
Wr45.' 7-MIJ (S dVO7'
h -se til vcvc-o ri-Ar
,41-L I-OCA7701C AIM
MUN I CIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING
DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME
PHONE
NEW
V�A-'Omnl\j
131-19-14CAI
E]UPGRADE
MAILING ADDRESS
LEGAL DESCRIPTION
LOCATION
NO, OF BEDROOMS
Well
Absorption area
Dwelling
PERMIT NO.
DISTANCE TO:
-1 BC) A-4-6
2
(L <
Manufacturer
Material
No. of compartments
LU �_
Lic. capacity in gallons
IF HOMEMADE:
Inside length
I
Width
Liquid depth
\000
DISTANCE TO:
Well
Dwelling
PERMIT NO.
_j 0 z
0 z
Manufacturer
Material
Liquid capacity in gallons
_j
DISTANCE TO:
Well
Foundation
C)
Nearest lot line
PERMIT NO,
47 B G
LU 3:
0
0 A-4-
W
_j FL �
No. of lines
Length of each li!i
Total length of lines
Trench width
Distance between lines
Z Lu
S4
inches
I.-
Top of tile to finish grade
Material beneath tile
Total effective n area
0
inches
lr��g
Length
Width
Depth
PERMIT NO.
LU
U
L
< I-
Type of crib
—
Crib clittr
Crib depth
Total effective absorption area
0. FL
Lu
A
LU
0
Well
Building foundation
Nearest lot line
DISTANCE TO:
C�s6',
Depth
Driller
Distance to lot line
IT NO.
_j
_j
w
3
DISTANCE TO:
Building foundation
Sewer fine
Septic tank
Absorption area(s)
OTHER
MVI:-
�fhol.612_
I
I
PIPE MATERIALS
SOIL TEST RATING
INSTALLER
REMARKS
L) c;-, rl Y\J
L.IX
e
C -C
MVGW�SQ P� t Fk) (6 U C=>LU S,
2_�
K�'Uff
0
06
r
L
)k-"PqVED DATE LEGAL
G
72-013 (Rev. 3/78)
IT
,. ,v# ,•�._,.; �x� mal y� i;
•
#
Y
L�
�
V
41
e i3)TIli
r
it
£
f
t5 S
y
C
`
x
F kr
ti
� t
f �
q`
•
#
Y
L�
�
V
e i3)TIli
r
it
£
f
t5 S
y
C
`
x
� t
q`
•
#
Y
L�
�
V
r
it
£
`
i
:E; a L--1 a FR
PERMIT NO. 'e. 780446
APPLICANT HANNON CONST 6511 GUAM
LOCATION WILCOX
LEGAL LIO B7. SAND LAKE SUBD #2 LOT SIZE
F-_� FE IF-., �--i i: -r,
6750 SQUARE'. FEET
TYPE OF SOIL ABSORIBTION SYSTEM IS: TRENCH
MAXIMUM NUMBER OF BEDROOMS = 3 SOIL RATING (SO FT/BR)= 125
THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS:
CoEEF:`r"� A �D- L-E:"lli-r" 3�r;E" 0 UE F� "T" - E-3
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD.
THE DEPTH OF A TRENCH OR PIT 15 THE DISTANCE BETWEEN THE SURFACE OF THE
GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET).
THERE 15 NO SET WIDTH FOR TRENCHES.
THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE
AND THE BOTTOM OF THE EXCAVATION (IN FEET).
F-OF-EQU I !E5uF=*_r I rl� -IF #=11 I* -JK !E; I 2'E:= IL "_ f3p2`1 f3FIL_L_CPP-J�_��
PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE
INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE
NUMBER OF RESIDENCES THAT THE WELL WILL SERVE.
__ — — -I- L. -I Cl r- ;;2" > I " _�-- F� E: 0 -r I Ca ""= " f;? E: FR'E-:: C -! U I Pit r=- LEN
BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS
DEPARTMENT 14ILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS
100 FEET FOR A PRIVATE WELLj OR
150 TO 200 FEET FROM A PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL.
WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN 20 DAYS
OF THE WELL COMPLETION.
OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE
AVAILABLE TO INSURE PROPER INSTALLATION.
I CERTIFY THAT
1: 1 AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: 1 WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
3: 1 UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THAN 3 BEDROOMS.
S I ("j N E D
APPLICA�n _c� �r4 S T
_Z�ZS
ISSUED P1 -DATE-
to 'Bu�- A16,2,
W O -CC) 7� S�T
Oto
I'v"0
IPLO�'
00-'—E
GAC.
6-7 Rj��'u e �- --spim [D
S46�'Lo
-DA IIA
W ot�:-T'S-a-
C-cu f�-CT-el/2
Q, F—CI.Lv t- C4:1 - - (&3 A C�'i I/- A � p . -*�D F7-1 #/ 61 // (h
0 SA-IAZO AAi
7Z -
D FC3 LQ— NL 0 1 1 97) 0 AnA— S�'Vt
SO f L -,S S e F: i C 94 7 - 7 C e V -
-a e)F—
T -3 ;c Lk' �E' 12 S-
-r JOC) Sit,
('(,�T�/ Ao'tc-a.
Air c
jm--r-�Iz
(-K L:) -0 py
!�;W)
Oral7L
'o P -x
CUTLER ENGINEERING SERVICES
1552 Orca Street
STRUCTURAL ENGINEERING
CIVIL ENGINEERING
CONSTRUCTION ENGINEERING
SURVEYING — LAND AND CONSTRUCTION
June 9, 1978
Allen Hannon
Anchorage, Alaska
ANCHORAGE,ALASKA
PHONE (907) 274-7711
RE: Soils Inspection for Individual Sanitary System
Lot 10 Block 7 Sandland Subdivision #2
Dear Allen:
Upon inspection of the test hole and the soils removed
therefrom, I have prepared the attached report sheet.
I do hereby certify the soils of Lot 10, Block 7 Sand -
lake Subdivision #2 for an individual sanitary system.
Sincerely,
CU R ENGINEERING
A C%
Z_
ec
D n,
ale L. Cutler, P.E./L.S.
�A Dale L. Cutle,
No. 1804-E
DLC:v
/3-7 �5
t3
6&UeC4,� J,-Le�
CHEMICAL & GEOLOGICAL LABORATORY
A DIVISION OF COMMERCIAL TESTING & ENGINEERING CO.
5633 B STREET ANCHORAGE, ALASKA 99518 TELEPHONE (907) 562-2343 FAX: (907) 561-5301
ANALYSIS RESULTS for INVOICE # 40951
Chemlab Ref.# 91.6555 Sample # 3 Matrix: WATER
Client Sample ID DRINKING WATER L10 B7 SAND LAKE #2
PWSID UA
Collected DEC 10 91 @ 11:20 hrs.
Received DEC 10 91 @ 16:15 hrs.
Preserved with AS REQUIRED
Analysis Completed DEC 11 91
Laboratory Supervisor EN -C. ;EDEE, '
Released By lam`
Parameter Results Units
-------------------------------------------------------------------------
NITRATE-N ND(0.10) mg/l
Sample ROUTINE SAMPLE COLLECTED BY: R.J.S.
Remarks:
Client Name :S & S ENGINEERING
Client Acct :SNSENGP
BPO#
Req#
Ordered By :R. SHAFER
Send Reports to:
1)S & S ENGINEERING
2)
..............
Method
--------------
EPA 353.2
Allowable Limits
----------------
10
PO# :NONE RECEIVED
..................................
1
Tests Performed
See
Special Instructions Above UA=Unavailable
ND-
None Detected
See
Sample Remarks Above
NA-
Not Analyzed
LT -Less
Than, GT=Greater Than
r.®,?Sc3s Member of the SGS Group (Soci6t6 Generale de Surveillance)
S. LEGAL DESCRIPTION
WINICIPALITY UF ARCHORAUT-1
MUNICIPALITY OF ANCHORAGE PEPT. OF HEALTH &
DEPARTMENT OF HEALTH & ENVIF30NMENTAL PROTECTIcWVIRQNMENTAL KOTECTION
825 L Street - Anchorage, Alaska 99501
-5e4r,(
NOV 16 1978
ENVIRONMENTAL
ENGINEERING DIVISION
NUMBER OF BEDROOMS
Telephone 264-4720 RECEIVED
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing.
1. PROPERTYOWNER
ED ' MULTIPLEFAMILY
PHONE
1391V
7. WATER SUtP4--Y
-7V 9
MAILINGADDRESS 260 6aAM
boe#=-- 5@WL—
0 COMMUNITY
PROPERTY RESIDENT (If different from above)
0 PUBLIC UTILITY
PHONE
8. SEWAGE DISP AL SYSTEM
INDIVIDUAL/ON-SITE**
-2. BUYER
PHONE
E:1 PUBLIC UTILITY
by this Department.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
MAILING ADDRESS
3. LENDING INSTITUTION
MAILING ADDRESS
4. REALTOR/AGENT
/3ZZ�,k /'
PHONE
MAILING ADDRESS 'T
'36 � -�:;7
S. LEGAL DESCRIPTION
Z-071 / a S 4 7
STREET LOCATION
7-g eC- 7-
-5e4r,(
0 �K
6. TYPE OF RESI NCE
NUMBER OF BEDROOMS
ZSINGLEFAMILY
ED one El Four 0 Other
0 �vvo 0 Five
ED ' MULTIPLEFAMILY
Oa-,�Three 0 Six
7. WATER SUtP4--Y
Ble" INDIVIDUAL*
ATTACH WELL LOG. A well log is required for all wells drilled
0 COMMUNITY
since June 1975. For wells drilled prior to that date, give well
0 PUBLIC UTILITY
depth (attach log if available.)
8. SEWAGE DISP AL SYSTEM
INDIVIDUAL/ON-SITE**
**If individual/on-site, give installation date
If systern is over two (2) years old an adequacy test is required
E:1 PUBLIC UTILITY
by this Department.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010(31781
k-MM401AK
N
ki
1�t
Development Services Department; Phone 907-343-7904
On -Site Water & Wastewater Section Fax. 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 011-132-27
1. GENERAL INFORMATION
Complete legal description Sand Lake #2 137 L10
Location (site address) 8333 Wilcox
Current property owner(s) Nlda Nelson
Mailing address
Real estate agent
2. TYPE OF DWELLING:
El Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 3
Expiration Date:
Day phone
Day phone
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
El
Private Septic
P
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ Waiver Fee $ _
Date of Payment 3 a.0�a Date of Payment
Receipt Number b �l �� Receipt Number
COSA # 03C 7 210 g2 Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures
outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or
wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated
herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and
inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State
codes, ordinances, and regulations in effect at the time of installation.
In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA
COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time
of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on
the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not
guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot
provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole
benefit of the owner listed above. Reliance on this report by another person is at their own risk. Pannone Engineering Services LLC highly
recommends buyers hire their own engineer to evaluate this report.
Name of Firm Pannone Engineering Services
Phone (907) 745-8200
Address P.O. Box 1807 Palmer, AK 99645
Engineer's Printed Name Steven R. Pannone P.E., F. ACE Date���
6. DSD SIGNATURE -
System #1 Approved for
System #2 Approved for
Disapproved
Conditional approval for
OF Aqs����
•�� 4 TH �.
bedrooms Steven R. Foniiolae
F.. CE 8149 iz
bedrooms�csl
bedrooms, with the following stipulations:
- - � PROGRAM
JJTCC
�l
A
O
By: Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
Legal Description: Sand Lake #2 137 L10
If more than 1 septic system on lot: COSA Checklist # 1 of 1
A. WELL DATA
0 Well log is filed with Onsite (or attached)
Date drilled 11/78
Total depth 242 ft
Cased to unknown ft
N Sanitary seal is functioning correctly
0 Wires are properly protected
Casing height (above ground) 18+ in.
Date of flow test for COSA 12/$/22
Static water level at beginning of test 116 ft.
Comments
B. TANK DATA
Age of tank(s) """'°°' years
Tank type/material s.pkdFBG
Measured operating fluid level in septic tank 50"
OR Standpipes/foundation cleanout per record drawing
Date of pumping 3/3/2022
D. ABSORPTION FIELD DATA `Nide trench
Which system tested (date installed) 2/15/22
Q ALL standpipes present per record drawing
Total measured depth from grade 10 ft (max)
Measured depth to pipe invert from grade 6 ft (min)
❑ N/A — pressurized field
F01 Monitor tubes go to bottom of effective. If not, state
depth into effective
A Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced gallons
Comments/Deficiencies: new field installed
COSA Checklist yellow sheet
Parcel ID: 01113227
Structure served by this system 1
Well production at time of test 3.3 gpm
Water storage tank volume na gallons
Well disinfected for coliform test? ❑ Yes 0 No
0 Coliform bacteria is Negative
Nitrate mg/L Q Nitrate less than MRL (ND)
Arsenic oZ ug/L arsenic less than MRL (ND)
Collected by PES
Date of Sample 2/23/22
C. LIFT STATION
❑ Required maintenance completed
Age of lift station years
Lift station material
Comments:
Adequacy test date new
Results ❑✓ Pass For 3 bedrooms
Fluid depth prior to test in
Water added gal
New depth in
Elapsed time min
Final fluid depth in
Absorption rate 450 gpd
Any rejuvenation treatment (past 12 months)
If yes, enter date
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
❑✓
Septic Tank/Lift Station on Lot > 100'
if No
*85 8
Community Sewer Manhole/Cleanout > 100'
❑ Yes
if No
ft
r7V Yes
if No ft
Neighboring Tank > 100' ❑ Yes
if No
*±85 ft
Private Sewer/Septic Line > 25'M Yes
if No ft
Absorption Field on Lot > 100' ❑ Yes
if No
*79 ft
Holding Tank > 100' 0 Yes
if No ft
Neighboring Absorption Fields > 100'
P -11
*+85
Animal Containment > 50' El Yes
_
if No ft
171 Yes
if No
ft
❑✓
Yes
if No
ft
If septic tank is under driveway, comment below
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' Q Yes
if No
ft
0 Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'✓❑
❑✓
Yes
if No
ft
Surface Water> 100'
❑✓ Yes if No ft
Property Line > 5'✓❑
Yes
Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
❑✓
Yes
if No
ft
Private Wells > 100'
❑ Yes if No 85-90 ft
Water Main > 10'
P -11
-Yes
if No
ft
Community Wells > 200'
121 Yes if No ft
Water Service Line .> 10'
❑✓
Yes
if No
ft
If septic tank is under driveway, comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
❑✓
Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
❑
Yes
if No
*5.0 ft
Wells on Adjacent Lots:
Water Main > 10'✓❑
Yes
if No
ft
Private Wells > 100' ❑ Yes. . if No *72.8 ft
Water Service Line > 10'
Fl�
Yes
if No
ft
Community Wells > 200' ❑✓ Yes if No ft
Surface Water > 100'
El
Yes
if No
ft
F. ENGINEER'S COMMENTS
* waiver on file
G. ENGINEER'S CERTIFICATION
/ certify that I have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
'2! 003LZE
COSA Checklist yellow sheet
... ..•
Steven R. Pann. re �
CF 8 149
\
_...W/LCOX STREET
o U'3"650.0
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Elmore Street
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
Arsenic Advisory
Certificate of On -Site Systems Approval # OSC221082
A Certificate of On -Site Systems Approval inspection and test of potable
water was recently conducted on the well water supply on Block 7, Lot 10 of
Sand Lake #2 -Subdivision. This inspection revealed an arsenic concentration
of 23 micrograms per liter (ug/L) for the property's well water sample. The
Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 ug/L for public drinking water systems.
While private wells are not subject to this regulation, EPA standards are
based on existing health information and can therefore be used to gauge the
relative quality of water from private wells. Information on arsenic is
available from the On -Site Water and Wastewater Program website
(www.muni.org/onsite) or at 343-7904.
This advisory must be attached to all copies of the subject Certificate of On -
Site Systems Approval.