Loading...
HomeMy WebLinkAboutSCHROEDER EAST BLK 6 LT 20ASchroeder East Block 6 Lot 20A #050-062-38 Municipality of Anchorage a 17 - - - On -Site Water and Wastewater Program • (907) 343-7904 fT ON-SITE WASTEWATER INSPECTION REPORT `UI Zf117 - Permit Number: OSP/S// 87 PID Number: OSS �6Z38 Dwelling:] Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New Ajupgrade Name: r ,. .S GO �EOLIA1 ABSORPTION FIELD ❑ Deep Trench ❑ Shallow Trench ❑Bed []Mound Address l�Gs%fC'� Other 16/T -- Phone Number of Bedrooms Soil Rating/ GPD/SF Total depth from original grade /� - Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade • J,, S Ft. Fill added above original grade Ft. Gravel depth beneath Ripe Ft. Gravel length 16'Ft. Subdivision Block Lot? / vq S b Z04 Township Range Section Gravel width / Beds: Number of Lines Distance between lines SEPARATION DISTANCES ! Ft. — Ft. To Septic Tank Absorption Field Lift Station Holding Tank Sewer. Total abso tion area L� Number of trenches Dist. between trenches From Line FEZ Ft. Well aQ l GCJ �� Sf TANK Oseptic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer/� C�(Z 6 i5 K- Capacity /�, /&)L Gal. Surface Water /�O /oo /.� Material Number of compartments Lot Line /Q /U/) NA Foundation /Q f l� �-f- — —. LIFT STATION Manufacturer Capacity Curtain Drain �� U�� Gal. Remarks T- Pump on level at in. Pump off level at in. High water alarm at in. /� lgy/46 Pump make and model Electrical Inspections performed by Installer PIPE MATERIAL House to tank i� Tank to JJ� drainfield U O3 __s r%F55dtzd Drainfield CO/MTa,ra Inspector O � �n .4 ' BENCH MARK (Assumed elevation) /41�10 ft Inspection �� 3� S 2m �� dates: S Location and description 1710C/SF 6 �C k 3`� 41h 17 COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL En�geeer,§. amp OF A I th Conditional Approval: DateP�� °oco°°no. o ° °• J e a n� Sie,en bY. En PE 6 56 - Approved Q &,(' Date A - A 40 32 B CO2 50 35 ST1 46 63 52 DC❑2 69 59 C❑3 59 63 C❑4 61 56 MT 71 63 well T)ecommissioned NORTHRIM ENGINEERING PO Box 770724iy+�Stm En . Eagle River, Alaska 99577 ��+ .• (� !� 907.694.7028 �y SCHR❑EDER EAST BLOCK 6 LOT 20A WASTEWATER RECORD SEPTIC REBUILD 1" = 50' RECORD LAYOUT !: MET. 5/17/17 12 of -3 3 W' i M W J D H ~ O i �' W c CK- O l/� �; a W z ii W I— rn i O CL W - IW G-, _ d W W ;Q LLJ U co U^ N V J —j w j� O) d Q O N .a a .. Lo. cr OC Nd .N Fd -Id Id 06 O IL Q Y I d O z . A o_ A Ql U Q —�- W v CY- 3 (Y' A z -P �, n,U� Pa w co I Ln U -P II L7 O O A d +' d Qi _`� I Lr) o coU N I\ LA w Q) o 60 0o ao LL] L ] f w 00 0 w o CL CD n 0II n > IIEDd O O +' o +' Lj -P n, o - d d W Pq O� > > +1 > > Uj W '� W � � L �o to d N ~ >,Ln C5 -5 Qi d ai >O \ Q U M -Y d -P O O- d LD O S N� O O W p u O LL- o �¢ +, o L N N Qj ~ O O @J �D f' d CJ'N 2 O O N H Pq f U II Ln co o O II +' +, d d > > O � d > I° a, 3 W' i M W J D H ~ O i �' W c CK- O l/� �; W W z ii W I— i CL W - IW G-, _ M W W ;Q LLJ U co U^ N V J —j w j� 3 W' W J D H ~ i �' W c CK- OL �; W W z CL W � ULi G-, _ M W CL LLJ �CRTI`� I M ENGINEERING S❑ILS LOG - PERC❑LATI❑N TEST Date Perf ormed; 7/10/15 Perf ormed For: Caroline Streano Legal Description: Schroeder East Block 6 Lot 20A 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - 14 - 15 - 16 - 17 - 18 - 19 - 20 - DEPTH (FEET) Organic SM Sand w/ Gravel T,H, Location: See Attached Design Groundwater? No Depth Water Depth After Monitorino,None Date /18/15__ # Date Gross Time Net Time Depth Net Drop 1 7/10 0 -- 7" -- 2 7/10 10 10 min. 101, 3" 3 7/10 12 -- 7" -- 4 7/10 1 22 10 min, 101, 3" 5 7/10 25 -- 7" -- 6 7/10 35 10 min, 101, 3" 7 7/10 37 -- 7# -- 8 7/10 47 10 min, 10" 3" 9 7/10 50 -- 7" -- 10 7/10 60 10 min, 10" 3" 21 - L� Percolation Rate 3.5 min,/inch Perc Hole Diameter 6" Test Run Between 2' and 3' Comments Performed By NorthRim Eng, I CERTIFY THAT THIS TEST WAS Performed in Accordance with All State/Municipal Guidelines in Effect ON THIS DATE. DATE: 7/10/15 NORTHRIM ENGINEERING �;*; PO Box 770724 , saw t Eagle River. Alaska 99577##, � 907.694.7028 �. TESTH❑LE LOG GE❑TECHNICAL TH2 7/10/15E�. Hltc.: i tc; rruMI- a VV 1-1...L 11,4% - Jim Sullivan, CPI�� r PO Box 770197 X2, Engle Eagle River, AK 99577 (907) 683-2510 (907) 243-2282 i i m (W)arct icpump. corn Well Decommissioning LOO, Legal Address: Suvdivision:Scluoeder Block: b Lot: 20a East T: R Section 1 cit: On-site Water & Wastewater Program certified contractor performing the well decommissioning: Name: 11m Sullivan Company: Arctic Pumii & � ell, Inc. Woll Decommissioning Date 10-7-15 Signature: f� Method of Decommissioning: -ANIC 15.55.0601.1 a.17 b.0 C. Location: Use the space below to provide a drawing of the property shoving the following items: • North Arrow • Decommissioned well • Other water wells on the property • Two separate swing tie distances for each well shown on the drawing Note: the swing tie distances shall be measured from either permanent structures or the property corners. Arctic Puml) & fr ll, Iftc. Page 1 o f I On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151187 Tax Code Number: 05006238000 Work Type: Septic Upgrade Permit Effective Dates: July 08, 2015 to July 07, 2016 Design Engineer: NORTH RIM ENGINEERING Subdivision: SCHROEDER EAST Site Legal Address: SCHROEDER EAST BLK 6 LT 20A G:0352 Owner/Address: STREANO-THOMAS CAROLINE 12415 E PRINCE OF PEACE DRIVE EAGLE RIVER AK 995777544 Site Mailing Address: 12415 E PRINCE OF PEACE DR, Eagle River Lot Size in Sq Ft: 27769 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: �"w 1. The abandoned well is to be decommissioned prior to Inspection Report approval. 2. Proposed system too deep for soils information submitted. The Engineer needs to do an additional test hole prior to the construction of the septic field. Construction may proceed at your own risk before the 7 day water monitoring is complete. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. Received B) Issued By: p UNICIPALIW OF Community Development Department Development Services Division On -Site Water & Wastewater Program y 1. Phone: Fax: ON-SITE SEWER/WELL PERMIT APPLICATION S 9 i JUN 17 2015 Parcel I.D. Property owner(s) -S T/ E,,4 AJ U G41ZG[,1A E Day phone SOT S Mailing address /2 n F P.f±lC r A Site address _ 9116"1= Legal description (Sub'd., Block & Lot) SP,ff 2 o En Elt- :?04 Legal description (Township, Range & Section) Lot Size 2 Z 76 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field Initial ElSingle Family (SF) Septic Tank '9 Upgrade E�4 (w/wo ADU) Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owngKor authorized agent) Permit/Rush Fees: Date of Payment: i0 Receipt Number: d=2!b Permit No. 13 S/j/571fl Permit App9-1-12.doc Waiver Fees: Date of Payment: Receipt Number: Waiver No. THS I� M ENGINEERING MEMO Steve Eng, PE, PH P.O. Box 770724, Eagle River AK 99577 (907) 694-7028 SteveEngPE@gmail.com Date: 6/17/15 Number of Pages: To: J. Crewdson PE, MOA On -Site Services Subject: Schroeder East Block 6 Lot 20A Septic System Upgrade An existing septic tank and seepage pit has failed on the subject lot. A new soil test was completed, silty sandy soil and no groundwater. The design calls for a seepage pit reconstruction with new septic tank. The entire subdivision is on public water and septic systems. The terrain slope is low relief at the site. The system size is a single family at 3 bedrooms. Please review the wastewater system design. I have included design plans & specs, design guidelines, & soil tests. If there is need for additional information or clarification please give me a call. Thanks -Ste �C2TN Imo_ ENGINEERING Schroeder East, Block 6 Lot 20A SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: This is an existing 3 -bedroom, single family home. The neighboring lots are developed- Public water serves this lot and most of the neighbor lots. The current septic tank has failed- the Seepage Pit is to be rebuilt. There is no space available for another system. The old log crib will be removed along with clogged drain rock. A new Steel Seepage Pit Ring will be centered, with cleanout. No adverse impacts are expected from tank replacement and seepage pit reconstruction. Easements are shown on drawing. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. • Two compartment, 1000 gallon septic tank. Watertight couplings on inlet & outlet. • 5' minimum between the tank and seepage pit. 10' to property lines. • Remove old Log Crib/Bad Drain Rock. Replace with 4' in diameter, 6' high steel perforated seepage pit, "Anchorage Tank or Equal". • 4' of cover or insulation is required for tank; an equivalent of 1" insulation for 1' foot soil cover. Minimum of 2' soil with insulation. • Tank & solid pipe must be set on well compacted, stable soil. • 4 inch diameter cleanouts with airtight caps are required F to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. • All cleanouts must extend to at least ground level. • In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. • Insulation must be placed over any pipe installed under driveways or parking areas. • Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, • Sewer Service Line is minimum 2% slope. • Septic Tank to be pumped every two years or when required. • Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal) DESIGN NOTES: 1. Existing Seepage Pit To Be Rebuilt. 2. Sewer Service Line minimum 2% slope. 3. Replace Septic Tank/Decommission Old Tank. 4. Lots Served by Public Water System. 5. No Conflicts Within 200'. 6. The abandoned well is to be decommissioned. 7. Add Foundation Cleanout (FCO). Old Utilidor Well Not In USe 0 0 On Public Water Line serlent 2y 5 P¢ Water \ 1" = 50' of 3 Decommission ❑ Tank, Replace th 2 Bdrr ew 1000 Gallon 5% Slope Septic Tank w/DC Water LM S"090 New FCO a Zy 0 N Existing Seepage Pit �O Reconstruct With N w o_ Pkv 9W0 'oi I Seepage Pit Ring Excavate & Replace G ADU Old Dralnrock 1 r Garag a THI 9 n o m 3� in I ti NI LO x II Septic Lot 21- Public Water OF A ,?�E..... SCHR❑EDER EAST NORTH?/Mr.. ENGINEERING BLOCK 6 LOT 20A PLAN PO Box 770724.. e LAYOUT :Eagle River, Alaeko 99577 72. s' WASTEWATER DESIGN �/z/ls 907.694.7028 SEPTIC REBUILD 1" = 50' of 3 W 4' 0. +' a 0� c� O j dj a(0 ° I m d m a 2` Q CD l LI Y O Q z L df a *' 0 W o ° o L W v A ( W ". Cl) w Q' `D L J Q a) a)� --� d W M U LO pq z= O (A U J 3 V � "'JI) ° d d N 4 O p J W z CL 3 LLJ O7 U j W LA O Vi 5 0 L CL d > d a W o 0 U L Li F— t U i' (h q ° J' `� U ' ao a,m aN ° a W W �' UI Y > u O :p d 0-5 +' 3 N N Ut ; d > W 3 L O EOl L +' VJ~ r+ �� NNS U U1 E (� C5_6 > W a£a -SEN O S S c p �S N aE�3 �+� ra: L L C:) daa ocn L ad Otia f vo ai I�.,rn . II 6 LJX1OO 0°�Vi tn a°6w U TU dU+�-� NYS-> d+' U O E U On �Q U� ( �d o N � -- U E L � Z Fw- z 1, ° 0) > I aL 01 4- �Q: O a Np 3 W 4 ~ a O- , 3c d, (.0Ou N U f O Q w viQv`"viu3va�w Ld R 14N (`7 d'N116 r-� n O n 1� S❑ILS LOG - PERC❑LATI❑N TEST TH I�- ENGINEERING Date Performed 6/5/15 Performed For: Caroline Streano Legal Description: Schroeder East Block 6 Lot 20A 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - 14 - 15 - 16 - 17 - 18 - 19 - 20 - 21 - DEPTH (FEET) Organic SM Sand w/ Gravel T,H, Location; See Attached Design Groundwater? No Depth -- Water Depth After Mnnitorino,None Date: 6/18/15 # Date Gross Time Net Time Depth Net Drop 1 6/18 0 -- 7" -- 2 6/18 10 10 min. 10,5" 3,5° 3 6/18 12 -- 7" -- 4 6/18 22 10 min, 10,5" 3,5" 5 6/18 25 -- 7" -- 6 6/18 35 10 min, 10.5" 3,5" 7 6/18 37 -- 7" -- 8 6/18 47 10 min. 10.5" 3,5" 9 6/18 50 -- 7" -- 10 6/18 60 10 min, 10.5" 3,5' Percolation Rate 3 min./inch Perc Hole Diameter 6" Test Run Between 2' and 3' Comments Performed By NnrthRim Eng, I CERTIFY THAT THIS TEST WAS Performed in Accordance with All State/Municipal Guidelines in Effect ON THIS DATE, DATE: 6/18/15 NORTNRIM *y49..... TESTH❑LE LOG ENGINEERING PO Box 770724 ..4t Eagle River, Alaska 99577 9°7.69,.'°2B T+F GEOTECHNICAL TH1 6/18/15 11 b 9 slowr � V) (7 z O O O O 'zy O O O O O O O O 7_ t7 ITI O n . 1► i r J a rc h tTj :7 i~ G Z7C 7D� O O O O O O O O O O O O CDp yv ITJITJ 11 ITI 171 111 �11 171 0 0 0 0 0 0 0 0 0 0 0 0 H O H O H 0.10 H H O H 0.0 H H O H O H O H O H O 3 H -3 -3 b 9 slowr � a r 0,4ti D h 00 O n . 1► i r J rc h tTj slowr r 0,4ti D 00 O n . 1► i r tTj :7 i~ G Z7C 7D� zto rn CDp yv ���i --U�!I , � A 4 VU�H A'T,N W Q W Vo A q f; KR` " Y 0 Q K A T: � DEPRRTMENT 6, HEHLTH AND FAN lRONMEHTHL |.JTFCA }0N 825 'L' STREET. HNCl5Gi, 264'�720 PERMIT NOi ( 790208 ) |PPLlCHNT PEGGY NEWMHN OCHTION SHME c> EGHL L20 B6 SHROEDER EHST 81 :1X 97 PRINCE OF PEHCE 00, E 7 pla HA l 1 49Ato, 1 0; ! P �:E,: !".: :�- ��T 1. �EV I F; V I "? Q A., A. 17U 70" 01 � CERTIFY THHT FHMlLIHR WITH THE REQUIREMENTS FOR ON—SITE SEWERS HN) 'Wil HS �ET �ORTH 8Y THE MUNlCIPHLITY UF IRNCHORHGP �� I WILL lNSTHLL THE SYSTEM IN 9CCORDHNCE WITH THE COMA CMGR'ER ANCHORAGE AREA Br `AIJGH Department of Environmental Quality �m - 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME00n sCcll?OE7/z MAILING ADDRESS --PHONE _/ LOCATION LEGAL DESCRIPTION LOT 13COS`, �o &/leOG067'C �U/6zl1w, SEPTIC TANK: qL'4� NgLll1 DISTANCE /�Q/ FROM WELL MANUFACTURER �T-P(l< J — MATERIAL (�7-ce L - NUMBER OF COMPARTMENTS Z INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY`0GALLONS. SEEPAGE PIT: NUMBER OF PITS I DIAMETER —ky-L OR WIDTH I�%r, LENGTHS, DEPTH 10/ LINING MATERIAL ��� CRIB SIZE: DIAMETERDEPTH —�_:_ DISTANCE FROM: WEL�/L' IZa TOTAL BUILDING FOUNDATION__ , NEAREST LOT LINE ABSORPTIONEFFECTIVE AREA (WALL AREA) 3y SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE �rI le CONSTRUCTION �t%iNIIF1i?�) DEPTH�00r l? DISTANCE FROM: BUILDING NEAREST NEAREST SEPTIC / OC/ SEEPAGE I ZO / FOUNDATION LOT LINE—,SEWER LINE___, TANK_0_, SYSTEM CESSPOOL OTHER SOURCES APPROVED——DISAPPROVED DISTANCES: INSTALLED BY: 88 k6 PIPE MATERIAL: L' 112oN LOT SLOPE: REMARKS: REMAR Nrlm,� w� DATE b DIAGRAM OF SYSTEM r / v /V 19) F APPROVED G/A. A.B. Form No. EQ -031 GREATER ANCHORAGE AREA BOROUGH pit O the•o DEPARTMENT OF ENVIRONMENTAL QUALITY PERMIT NO IInO 4 3330 "C" STREET ANCHORAGE, ALASKA 99503 o Uhf TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM ---- APPLICATION AND PERMIT NAME OF APPLICANT ��'e ��-/ MAILING ADDRESS\ G�J— J-4 �N � � Ji HONE INSTALLATION LOCATION �i�^ _.��- ���`--<>✓c -/� F -I ✓n -t LEGAL DESCRIPTION INSTALLATION OF: SEPTIC TANK SEEPAGE PIT DRAIN FIELD _ OTHER TYPE AND SIZE OF FACILITY TO BE SERVED S� FINANCED THROUGH SOIL TEST RESULTS COMPLETION DATE ANTICIPATES TO BE INSTALLED BY I THIS PERMIT IS NOT VALID WITHOUT SOI FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL, INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION, SEPTIC TANK SIZE TYPE SEEPAGE AREA SIZE TYPE MINIMUM DISTANCES, REOUIREMENTS FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT L b , , DRAIN FIELD SEPTIC 'TANK TO SEEPAGE PIT WALL SEPTIC TANK '--5 , SEEPAGE PIT �-� DRAIN FIELD TO NEAREST LOT LINE. 11 WELL TO SEPTIC TANK/ / SEEPAGE PIT DRAIN FIELD / /J /) ALSO CONSIDER AREA WELLS. WATER MAIN 'TO SEPTIC 'TANK /Q ' _, SEEPAGE PIT Zip DRAIN FIELD //) ��)/� SEPTIC TANK. /�0 /_, SEEPAGE PIT /00 DRAIN FIELD yl10y TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. A INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL, 13ACKFILL CONFORM TO BORe"H REGULATIONS REGARDING INSTALLATION. G.A.A.B. OR LICENSED DESIGNER DIAGRAM OF SYSTEM I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 26-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. DATE — APPLICANT'S SIGNATURE