HomeMy WebLinkAboutSECLUDED HILLS BLK 2 LT 2r � � 11-'xLl 3- t (C) SUBMITTA AUG 092018 Municipality of Anchorage Community Development Department Page 1 of 2 On-Site Water and Wastewater Program 4700 Elmore St. •P.O. Box 196650 Anchorage,AK 99519-6650• http://www.muni.org/onsite• (907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181194 PID Number: 017-343-10 ❑ New ❑✓ Upgrade Name: ABSORPTION FIELD ALAN & PAMELA BAILEY Address ❑ Deep Trench El Shallow Trench ❑ Bed ❑ Mound 13265 BADGER LANE ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot Ft. Ft. SECLUDED HILLS 2 2 Fill added above original grade Gravel length Township Range Section Ft. Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES Ft. Ft. To Septic AbsorptionHolding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Lift Station Tank Line Ft2 Ft. Well 106.2 N/A N/A N/A TANK ❑Septic I 1 S.T.E.P. ❑Holding 0 Other Manufacturer Capacity Surface Water 100+ N/A N/A N/A ANCHORAGE 15000a1. Material Number of compartments Lot Line 53.4 N/A N/A N/A STEEL 2 NA Foundation 17.8 N/A N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain N/A N/A N/A N/A ORENCO 250 Gal. Pump on level at Pump off level at High water alarm at Remarks TANK REPLACE ONLY 40 in. 36 in. 45in. Pump make and model Electrical Inspections performed by - P2005 MOA BUILDING SAFTEY PIPE MATERIAL House to tank 3034 Tank to 3034 Installer drainfield A+ HOME SERVICE Drainfield CO/MT Inspector PES BENCH MARK (Assumed elevation) 706.Oft Inspection t Location and description 1 dates: - 8/3/2018 rt 8/6/2018 3rd - - 4t„ NE BOTTOM TRIM COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp ..r OF A�,� \� Conditional Approval: Date ..g...1 -,,:)....-•O. .cS',�lcy t ' 1• •never •FY.'ISonnorae'P C5, 811449 Approve. 1 Date C.-13'JO ��.�• �- l\\�� �.. Inspection Report__1-1-12.doc 10'x30' Anchor -E_ s.mtC /' _ , __,._ ,---, --,..,. • _ _ _ _, , ,--7\7--- ,_ J T1 4.6 18.7 �/ \ �/ / —.,-/%'+++** ,.__s•. .5 T2 12.0 17.2 LS 12.5 16.8 / EXISTING ABSORPTION BED _' 695 / TRUE N 0- , SCALE : 1'=50' 700 705 710 / 715 VJ\ ----L, \ / / /- / 1 r\ � l LS ' -1 3 / 1 \ — ' T2 INSTALLED 1500. S.T.E.P. TANK 1 / _ / 4 ^`Alirillillmuft,,..._ ABANDONED EXISTING TANKS 3 \ • BDR I� /PER MOA CODE \ T A . / /P �� /— — 1 106.2 / / N ,.O \1 ° \ 'LI r 7./ \ 1 , N / N t / ( 1 f � 1 1 f A r r l • / 1 / z • I �N _ / I // eqD. •R Loge WELL E i J _ I — / // WELL (E) l / ~A} j� f \ // / / / r—w w — WATER L-tNE'/ / v4 ~ - / 1 / /- 7„--- WELT RADIUS ) 1 / 1 —ss ( ss — NEW SEPTIC L Z F- F- o o o a 1— z z to W W 1_J _J - CD o J OG./FG. _ — 707.0 r 702.4 / 1500 g S.T.E.P. PROFILE — SCALE: NTS NOTES: PANNONE ENG SVC, LLCDote , OF" .• RECORD DRAWING _ P.O. BOX 102954 ANCHORAGE, AK 99510 P8/8/18 PHONE (907) 907 ( )272-8218 FAX 272-8211 Scale ar•iiillo•'•••• P.I.D. NO — SECLUDED HILLS B2 L2 - = -7-343-10 ALAN Sc PAMELA BAILEY •• }'even A:•-anriaie' pERMIT N0. DRAWN ACP .^•;• CE 8149 0SP181 194 13265 BADGER LANE SITE PLAN ANCHORAGE, AK 99516 '-:� Sheet 2 OF 2 rr0 MUNICIPALITY OF ANCHORAGE .Ment S, f On-Site Water&Wastewater Program 10 P• r t` PO Box 196650 4700 Elmore Road i l Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 „ n• "s http://www.muni.org/onsite +' 1)c I'arttncni ,Nf XONPGt* On-Site Wastewater Disposal System Permit Permit Number: OSP181194 Effective Date: 7/18/2018 Work Type: SepticTank Upgrade Expiration Date: 7/18/2019 Tax Code Number: 01734310000 Site Legal Address: SECLUDED HILLS BLK 2 LT 2 G:2937 Site Mailing Address: 13265 BADGER LN, Anchorage Owner: BAILEY ALAN I & Lot Size in Sq Ft: 51506 Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 4 This permit is for the construction of: ❑ Disposal Field Q Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By`\ ,� � '', Date: 6` 7 t8 I� Issued By: f 4i h'.((L4 CQ' Date: MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water& Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 017-343-10 Property owner(s) Alan Bailey & Pamela Rowell Day phone Mailing address 13265 Badger Lane Anchorage, AK 99516 Site address 13265 Badger Lane Legal description (Sub'd., Block& Lot) Secluded Hills Block 2 Lot 2 Legal description (Township, Range & Section) Lot Size 51,506 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ❑X Upgrade Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Mu ••••.I C..- . tgn to -,o Ipro.- • C;', err or authorized agent Permit/Rush Fees: 15•D D Waiver Fees: 1 Date of Payment: 13 ,204 Date of Payment: Receipt Number: 0 ' I C Receipt Number: Permit No. •S i or Waiver No. Permit App_:-:•:_.,c: Pannone Engineering Services ac Steven R. Pannone, Principal Registered Professional Engineer E-mail:steve@panengak.com July 11, 2018 Subject: Secluded Hills S/D Block 2 Lot 2 Tank Replace Permit Request Design Narrative This is a design narrative for a permit to install an upgrade 1,500g S.T.E.P. Tank to replace three existing tanks, which are over 35 years old, to be issued for this property. The three existing tanks will be decommissioned per code. Currently the lot is developed. The proposed system will utilize a replacement 1,500g S.T.E.P. tank that will be connected to the existing drain field. The existing tank is located approximately 105' from the well. The proposed tank will be placed outside the existing well radius. All required separation distances will be met. 1. Upgrade Tank Design. A foundation clean out installed if needed. The tank will be located: 5'+ from any property line or drain field 10'+ from any water line or building foundation. 100'+ from any surface water 100'+ from any private wells 200'+ from any public wells The proposed installation will not affect the future development of the surrounding or existing lots. If you have any questions or concerns, please contact me at 907.272.8218. Sincerely, Steven R. Pannone, P.E. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 3 ir a/ N.m ...: ..I •. SCALE • •�, 1„ ���^: STEVEN R. PANNONE 4, = 5 O CE-8149 ;4% o 270. 00 w•h ••1 ?../ •�• N69 9'f0 , -,- .t D i*FESSI°��, __')2°.' — — -- -- — — — �a >Jl_P `Lv\cr, eN 1 E mtl��) Ccs Li 11 x z► o ��Y soiLAX,s , T3 r✓o -1-o — 4_____________,rf 17 a.YOritAi 4 4------- r o tiI 1 ' i- I h /5oo9 2 9' I 4)(1' �� S, TdNdi, 5/, 506 F pal / h ( r / �� a _ CO -rfat-i.& s It L_s. �S, Vi o ! to sii // „‘I A-BAND0Nt�EQ c_e9 �, a ti. USE ZOIV+r ,� 0)/5c) APPROVED f ,i/ / Dy .___. r__-_cidizidx-49:2 ---- . . If, z1 / o/ 4, ,0 L:- Date {'1°� All work shall be done as shown on this N �E) plot plan. Approved plans and speetti- '/�J `�0 ��.25'' `^'6u' cations shalt not be changed, modified ' ified �'� BAD�E� �' /�5 p / : t, ,-,•,t ,”-I1,,,t+ first obtaining a �:d7 �13. ,.r .+`t' .\u L� ?Rs-- 4t OF_A1 t�1 .. Qs1-11 LEGEND 2 *.49TH 9*fie 0 5/8' REBAR SET THIS SURVEY - = iii. _r !?. • el; LESLIE L BRAi7AIN .Z DRAINAGE ARROW (t:�j' IAC.. y1-F X SPOT ELEVATION _ illiOft ,\%'> )P OF FOUNDATION WALT. LEVATION. Portion 0 IT SHALL BE THE RESPONSIBILITY OF THE BUILDER a rte' NO Portion of this /V6' '7f DATUM OR OWNER TO VERIFY THAT THE BUILDING LOCATION tcture shall encroac, 'c\'AT1GN5 BASED ON SHOWN MEETS ALL SUBDIVISION COVENANTS ANDLOW, Any F4foa 4EPARED FOR, LOCAL ZONING CODES AND ORDINANCES. ALL LOT Karg, j"on7"nOC/m9 INFORMATION SHOWN IS FROM RECORDED PLAT ONLY. PLOT PLAN I HYCK LOT 2 , BLOCK 2 LR 1DA4-2°_83 NYMAN SECLUDED HILLS SUB ,K !GRIDz,037 &HAYES a. JD 9soe.0 ,.4.M,., ._.,...,.. 1+0..,.0•1 (P dl - I ) Municipality of Anchorage Page I of 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: Sw_g2o 107_ - ____ _ PID Number: Name: ALAN koRPl Wastewater System: L-1NewIg Upgrade Address: 132(65 B bGER LANE ABSORPTION FIELD Phone: 3145- — (o105 No. of Bedrooms. LL I *� LI Deep Trench CI Shallow Trench 'N Bed ❑Mound ❑Other LEGAL DESCRIPTION Soil Rating o.a' Total Depth from original grade 3 GPD/scl. FI. Lot: Block: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe 2 2 SECLUOEb NILLS 2.5 Ft. 0.5 Ft. Township: Township: 771 12 N Range: 3 w Section: 27 Fill added above original grade: 0.5 Gravel length: Ft. Ft. WELL: Fx1571,RNew I] Upgrade Gravel width 21 Number of lines: 4 Distance bSeenlinF' Ft Classification (Private, A.B,C): Total Depth: Cased To. Total absorption area: Pipe material: FL Ft. $(0I SO. Ft. I IN PVC Driller: Date Drilled: Static Water Level: Installer:+ A HoME SERVICES Dale insjailed: I 613-S /92 Ft. Yield: Pump Set at: Casing Height Above Ground: TANK GPM FI- Ft. SEPARATION DISTANCES XSeptic EJ Holding OS.T.E.P. To Septic Absorption Lift Holding Public/Private Manufacturer: Capacity in gallons: From Tank Field Station Tank Sewer Lines ANCHORAGE TAN(C E>CIST-loo0 NEW •500 Well 1oS ro c.0 / 15S 1 110 _ r 80 Material: 5TEE L Number of Compartments: 2 I S� Water iloot i/oo' 7/00' — ,/oo1 LIFT STATION Lot Line I 45 I 45 , f5 - , tfD Site in gallons. 580 Manufacturer: ORENCO ANCM, TAN 1: Foundation _ 2D/ Ssr 35 / _ O "Pump on" level at: 31" "Pump off' level at: 271j High water alarm at: 3711 CurtainPump Drain - -" "-" - Make & Model Y2 KR ORENCO Electrical Inspections performed by: Muw OF ANcNQRA6E Remarks: 5-1,1r the ort In a1 1000 Se /zc /gntz BENCH MART( ar S 14 r/ In a&C- Com d. 't wor referInea In Location and Description: TOP of DECK Ncx-r -ro 4ouSE f. COMAI0Fl 10 eru;re , A new SAO t/ S fic Int, k woJ 1'nsS , I vs Gt n aGl 6 CC/AAI S-00 a 1, tan k w, Orenco. H. S, _ Assumed Elevation: /00.0 The SOIL CL6S. ✓Jed 11 S114Akl` �ur9 er 7eietA shown on r,(ert n olcu�( ENGINEER'S SEAL www .mow J1 \� . OF �j��� ',,,...,.,,',T, a • • � -� V V "hp durfbcAhon i Ino, crAot {tole S acre Ls per cz rovecf`aa1 at -ray t�coF1 and Seea,1 fr Over sgp1-te s ycckM a heinC' dont by 2,w4r. Inspections performed by: FtA7'ro? TCCH SVCS Dates: 1st 6/3/92 �10 � �a�- :*C*be 49TH* •op*« _ 2nd _ G �3�9z _ 0 Flnaf 61S'(92 Department of Health A pduuuman Services approval jl �•••••••"'••"•••••�•• •. THLODORC F. MORE ,^ �9 ` ; CE-3589 ,- Reviewed and approved by: _�' �21�-- Date:4,�•�......^����av P2tt'�s G-VlU tneV. s/Bl) MUA 25 Permit No. S W `i 2 010'7 Page 2 of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION , P.O, Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Legal Description: LOT 2, SLk 2, SECLUDED HILLS PID No.: 01734 310 NORTH WEST MON1Y"O2 TV3G MEW SOIL, AIRS 6E 0 E-_� M.T. T.B. M. DOUBLE NEW SO0 64L LIFr STA , N6w Soo C, SEP. TAkk ALARMNouSE EXtST,t4G INSIDE --- 'r) 1000 GAL. GARACe 5E P. YAt{k B HOUSE CoRNERS B Soo GAL 1 �. /0 SJANk C.o. 31.57 0 1-I5T STA. tf6,51 39 MAN HOLE - WELL t1ORTHIVEST 90' 1D6 M.T. SOIL 6��� A IIS. 8 E D ���(`T�� AGE �4 ENGINEER'S SEAL _ \ SCALE % 1 --50 0 ; ,9TH 0 k � Flattop Technical Services # : THEODORE K. MOORE ; � � �� �'• CE 3589 - .� Ar 14530 Echo Street Anchorage, Alaska 99518 �i`�y•"""••••F•��°•P PIp12SS`' k 1b` 72-013 A Me Q1Q11 MnA 9s . Permit No. _ S W q 2 010'7 Page 3 of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 0 Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Legal Description: LoT 2 SLK 2 , SECLubED HILLS PID No,: 0I f3q 3io _ "TOP of DECK.; NEXT TO HoUS�00.0 00- GROUND ELEV. q7.7 NEAR sfPvc vAN 5 EXIST, NE W 1000 CAL Soo CAL SeP.TAAk SEP. TArlk 92.4,-) q2.2' VERTICAL SCALE NO tlOPIZO TAL SCALE 72-013 A (2/91) MOA 25 NEw SOO GAL LIFT STA. Ftq2.1' 100.0 6ROvr4O ELEV. OVER BED (BFFOPE- �TuPsofc. + RESEEDING q7.6� INVERT ELEV. ALL DIST, PIPES W AasoRBTIONI aED DRY -e, ELEV, 87 /4/ Flattop Technical Servi eE 14530 Echo Street AnchorageAnchorageJ Alaska 99$16 ENGINEER'S SEAL :THEODORE F. MOORE •.• CL • 3589 'Slop,� PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON—SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW920107 DESIGN ENG.INEER:FLATTOP TECHNICAL SERVICES OWNER NAME:KORPI ALAN A OWNER ADDRESS:13265 BADGER LN ANCHORAGE, ALASKA 99516 PARCEL ID:01734310 LEGAL DESCRIPTION: SECLUDED HILLS BLK 2 LT 2 LOT SIZE: 51506 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: DATE ISSUED: 5/27/92 EXPIRATION DATE: 5/27/93 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE: FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: n ISSUED BY: DATE: 5 ✓ 7 19'e DATE: J 2 7— �'2 CIVIL & ENVIRONMENTAL ENGINEERING • ENERGY CONSERVATION & ANALYSIS THEODORE F. MOORE, P.E. PH: (907) 345-1355 May 18, 1992 M.O.A. DHHS P.O. Box 19-6650 Anchorage, AK 99519 Dear Sus: 14530 ECHO ST. ANCHORAGE, ALASKA 99516 The purpose of this letter is to provide the required design narrative in support of our application for a permit to construct wastewater disposal facilities on Lot 2, Block 2, Secluded Hills S/D, located at 13265 Badger Lane. Soils logs, perc test results, a site plan, design drawings and specifications are enclosed for your review. This upgrade is proposed because a recent adequacy test indicated that the present soil absorption trench was operating in a surcharged condition, and is probably impacted by seasonal high groundwater. The proposed system will be constructed in the vicinity of test hole #1. As can be seen from the soil log, the native material between 3.5' and 5.5' is a slightly silty gravelly sand with a measured perc rate of 2 minutes per inch. Using the soil application rate of 0.8 gpd/sq. ft. specified in the wastewater ordinance for soil absorption beds constructed in material with a perc rate between 1 and 5 minutes per inch, this 4 bedroom residence requires a total absorption area of 750 square feet. The proposed 20' wide x 38' long design has a total absorption area of 760 square feet. Since the proposed soil absorption stratum is at a higher elevation than the septic tank, a lift station is necessary which will enable pressure distribution of the septic tank effluent. The hole size and spacing is based on a design pump rate of 20 gpm. Each 5/32" hole will pass 0.64 gpm at 5 feet of residual head or 0.5 gpm at 3 feet of residual head. The proposed design provides for a total of 38 holes spaced at 4' on center, which will accommodate the design flow. The topography in the area of the proposed construction slopes down towards the west at approximately 5%. The proposed replacement site is characterized by similar soil conditions and topography. The proposed project will have no impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any impact on reserved space/surface and subsurface, or on drainage. Please give me a call at 345-1355 if you have any questions on this submittal. Sincerely, Ted Moore, P.E. Lor I m Ni Lor 16 iUSTAMENA TERRACE" LOT ISA SEPr(c 0 S YS TEM ._�y 270' Q lo'UrILITY ESMT. REPIAcenenlr v 0 SITE T.N.#aq k �a N f5 20' x 3a' LOT 2 Sora A•os, eEo SL k- 2 T.FI.I Q M. T. O � 7.0 LANF EXISTING TRENCR --z'. To Qp ABAr�DoNfD � r3oR��r FIoUSE LOT 3 EXISTItgr,/// 1000 GAL. Sr pTIc TANk To 6E REPI.ACC_O HOUSE w• N�+w r�oo rFA� 57'Ep TARK cr?4NCo c ipr crN. W EL L Flattop Technical Services 14530 Echo Street Anchorage, Alaska 99516 LoT2, SLI<2, SECLUDED HILLS SEPTIC SYSTEM UPGRADE SITE PLAN SCALE I`.So1 NOTE'. TRIS Is NOT DA,rE: s/92 A SURVEYEo PLAT, DWN BY: ALL LOCATIONS ARE APPRox (MATE , 1'14" SCHED 40 PVC NDN -PERF A 20` p _ 1'/µ° SCHED 40 ti PVC Not,( -PERF NO PLAN VIEW o 'T°° GAL ° srcp rA Nr, I"= 10` W. oREnco" 4«r .srAr/ON SOIL COVER ORIGINAL 3 RouNA �I �� 2" RIGID WS)LATION x *4,�SAIND " FILTER FABRIC f �Y(,. PVC g ± P'r + sM 9",i SE WE R ' GRAVEL LEVELING Cou SA/SM 2° S E CT I O N A- A Flattop Technical SdMces I " = 514530 Echo Street Anchorage, Alaska 99516 ,rro ur At _44 :490k, THEODORE F, MOORE , ' At � ,�• CE .3589 Ve AV A.�kthAvev IOT21, RLK2 . SECLUDED HILLS SEPTIC SYSTEM UPGRADE PIAN 4. CRoss - SEC_TIDN SCALE' AS SOWN DATE : 5(I�9z 2Ev; &-/22/92 DWN BY' Ti I'/y I, SCHED 4o PVc LATERALS M,'(; W S/32" HOLES SPAc¢D 4' O.C. LIP ORIENT }TOLES DOWN 5 STA66ER Note SPAciNG IN AID 3. PIPCS i M.7. p 5' ALL JoiWT5 To BE GLvED 20` p _ 1'/µ° SCHED 40 ti PVC Not,( -PERF NO PLAN VIEW o 'T°° GAL ° srcp rA Nr, I"= 10` W. oREnco" 4«r .srAr/ON SOIL COVER ORIGINAL 3 RouNA �I �� 2" RIGID WS)LATION x *4,�SAIND " FILTER FABRIC f �Y(,. PVC g ± P'r + sM 9",i SE WE R ' GRAVEL LEVELING Cou SA/SM 2° S E CT I O N A- A Flattop Technical SdMces I " = 514530 Echo Street Anchorage, Alaska 99516 ,rro ur At _44 :490k, THEODORE F, MOORE , ' At � ,�• CE .3589 Ve AV A.�kthAvev IOT21, RLK2 . SECLUDED HILLS SEPTIC SYSTEM UPGRADE PIAN 4. CRoss - SEC_TIDN SCALE' AS SOWN DATE : 5(I�9z 2Ev; &-/22/92 DWN BY' Ti Flattop Technical Services 14530 Echo Street, Anchorage, AK99516 -'hone (90 7) 345-1355 Lot 2, Block 2, Secluded Hills 13265 Badger Lane Wastewater disposal system installation Specifications Revised 5/22/92 1.0 General: 1.1 The scope of the project consists of replacement of the existing 1250 gallon septic tank with a new 1500 gallon STEP tank with an integral "Orenco" lift station which pressure distributes effluent into a 20' x 38' soil absorption bed. 1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor deviations from these drawings may be allowed or required by the engineer conducting the inspections. All construction procedures and material specifications shall conform with Municipal and State requirements. All separation distances shall be in conformance with Municipal requirements, unless specifically waived. 1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any buried utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is achieved after settlement and that there are no residual depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 The homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the construction. 2.0 STEP Tank: 2.1 The existing septic tank is to be properly abandoned by pumping, crushing and burying it at a site designated by the property owner. 2.2 A new 1500 gallon STF,P tank as supplied by Anchorage Tank shall be installed in the approximate location of the present septic tank no closer than 100 feet from any private well. The tank shall be buried no deeper than 4' - 6", and the tank shall be equipped with a 5' insulated manhole riser. The wiring penetration through the manhole riser shall be located above ground level, or the space around the wires completely sealed with caulk. The lift station pump shall be an "Orenco" package system as supplied by Anchorage Tank. Special care shall be taken thoroughly compact the material beneath the inlet and outlet pipes and to protect them against displacement or breaking as the soil settles. 3.2 The contractor shall be responsible to obtain the necessary Municipal electric permit and inspection, and to provide a copy of the electrical inspector's report to the engineer overseeing the construction of the wastewater disposal system. 3.3 The on, off, and alarm floats shall be set at the elevations specified by the lift station supplier, and their proper operations shall be verified by the contractor. 4.0 Soil absorption system: 4.1 The soil absorption system shall be constructed by stripping the overlying peat and sandy loam strata off the proposed 20' x 38' soil absorption bed area to expose the top of a slightly silty gravelly sand stratum at a depth of approximately 3' below original ground level. 4.2 Care shall be taken to not overexcavate the site. The bottom of the excavation will not be level. The bottom of the bed shall be leveled by placement of a leveling course of coarse pit run NFS sand. 4.3 A total of 9" of approved sewer gravel shall be placed in the bottom of the excavation with the perforated distribution pipes laid level such that the pipe inverts are no less than 6 inches above the bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing the #200 sieve. 4.4 The discharge pipe from the lift station and the distribution pipes within the soil absorption bed shall all be 1.25" dia Schedule 40 PVC with all joints being glued. The distribution laterals shall have 5/32" holes drilled in the bottom at 4' centers with the hole spacing staggered in alternating rows. 4.4 Monitor tubes shall be of 4" diameter and installed in the locations shown on the design drawings. The portion of the monitor tube extending through the sewer gravel shall be perforated. 4.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. 2" of burial type insulation is to be placed over the entire top surface of the gravel, in addition to the filter fabric. A minimum of 2 feet of soil cover is to be placed over the filter fabric. 4.7 The top surface of the cover material shall be raised a minimum of 6 inches higher than the surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill slopes shall be no steeper than 3:1. 4.8 All lawn areas disturbed by the construction and/or soil absorption mound top and side slopes shall be covered with 4 inches of topsoil and seeded with an approved grass seed to promote rapid revegetation. This work is to be done by the property owner after the backfill has had a chance to consolidate. 5.0 Inspections: 5.1 A total of 5 engineering inspections will be required during the course of the project: (1) initial stakeout with the contractor to establish the location of the system and to discuss the plans, specifications and construction procedures, (2) after the native material has been excavated to expose the infiltrative surface to ensure that it is level and at the light elevation, and conforms with the soil test information, (3) after the sand leveling material has been placed, (4) after the sewer gravel is in place and the distribution pipes have been laid and connected up to the septic tank, but prior to placement of insulation or filter fabric, and (5) after final backfill and grading is complete. The lift station requires one inspection after the tank has been set level and the piping connected, but prior to backfill. This inspection may be incorporated with any of the above inspections. 5.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in advance to ensure the availability of the engineer. Flattop Teclin4cal Services 14530 Echo Street Anchorage, Alaska 9951f, 0�t Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST �.�,,•cpy. •�y. •�•••////-iJJ-��•'••. •:obi' i 00H•Y••••• IB• THEODORE P. MOORE '•• CE • 3589 of .041 r: H • tk l �a�—J PERFORMED FOR: ALAN KORLDDATEPERF'ORMED- 4f 2.8 — S•wq-z LEGAL DESCRIPTION: L2, B2. 8ECL UDtD WILL 5 Township, Range Section: SEC 27,, T121`4. R 31,V DEPTH PT SLOPE �.•_,�R•P.y,�L�pt �_ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 COMMENTS SM REDDISH SANDY LOAM GP/GM SOMEWHAT 51LTY, SANDY GRAVEL SP/SM SLIGHTLY SILTY, GRAVELLY SAND SMALL 920 SEEP AT ONE CORNER of 7 -i= -.sr P rr ML 5P/SM SLIGSH-wl SILTY, GRAVELLY SAMb ML WAS GROUND WATER I1`40I5TINCT TRANSITtot4 ENCOUNTERED? SM SILTY GRAVELLY IF YES, AT WHAT SAND DEPTH? B.H.Depth to Water Aller Monitoring? DRY Dale: S L O P E Reading Date Gross Time _ ■_■■■pq Depth to Water Net Drop 12"PRe oA 5 Q2 12:16•3o 271g No 4 60 12:20.00 12'. 20: 3o 23 '/ 27 3/ START T Milo 23 M/g ■Elm 3 3/ s + A20 In MEIN __21 23 %z t Hzo 12 31: 00 12'. 31: 30 3 21 7/ 23 yZ 1 S 12'• 34: 30 3 21 i/s s Reading Date Gross Time _ Net Time Depth to Water Net Drop 12"PRe oA 5 Q2 12:16•3o 271g 4 60 12:20.00 12'. 20: 3o 23 '/ 27 3/ START 12:7.4:30 23 M/g 12:2'7; 3o 3 3/ s + A20 12:28 "00 __21 23 %z t Hzo 12 31: 00 12'. 31: 30 3 21 7/ 23 yZ 1 S 12'• 34: 30 3 21 i/s s PERCOLATION RATE�•g_" (minutes/inch) PER(: HOLE DIAMETER i3 TEST RUN BETWEEN4_FT AND q• 5 FT /- See J cormtr o orf p'r no g!2gfci+� ry crn alums« /Y�i^ PERFORMED BY: _FLATTOP SEC , SVCS, I _wu,,V_ .— CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: A-V 7 6 /9 2 72.008 (Rev. 4185) — Flattop WbEliical Service 14530 Echo Street Anchorage, Alaska 9951r, Munlclpallty of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST T H. #2 PERFORMED FOR: ALAN KORPIDATEPERF'ORI LEGAL DESCRIPTION: L 2, B2, 6 ECL UDICD R ILL 5 Township, Range, Section; 5EC 27 DEPTH PT 1 SM REbbISH 5ANDY LOAF 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 COMMENTS 5tA SILT`( FINE SAND POCKE1-S OF CLEANER SP 4-- H,.o SEEP ML GRAVELLY SILT DRY CRvMBLI AFTER DuG o SIDES OF HOLE SME/ SLOPE rn SNI SILTYi FINE SAnlb LPRE WAS GROUND WATER ENCOUNTERED? Y S sP/5M 5L16NTLy SIL7YF YES, AT WHAT L GRAVELLY SANA DEPTH? Seed. to H I P E Deplh to Water Altel SP CLEAN Monitoring?' 13 B•G.L, Dale: 6/1219Z GRAVELLY SAPID B. N 3�www .0000• pTHEODORE F. MOORS; i•• CE • 3589 •` 6 LIN lid°1 Gross Not Time Time .�■__■ ■R■■ ■1 .o HIM MEN Reading Date Gross Not Time Time Depth to Net Water Drop PERCOLATION RATE tminutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND FT PERFORMED BY: FLATTOP TECf{ SVC C ��� %I —_�-- -- —' — — CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 9 Z 72.005 (Rev, 4/85) f'Iattop Te6alvcal Services 14530 Echo Street Anchorage, Alaska 99511; Municipality of Anchorage (*4D DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST TN,#3 THEODORE P. MOORE 1 ill":- #* • 3589 6- 41 A •. .• PERFORMED FOR: ALAN KOR P I DATE PERFORMED: LEGAL DESCRIPTION: L2 B?_y SECLUDED HILLS Township, Range, Section: 5EC 27 T12 DEPTH P.I- SLOPE erc oiof �r 1 ISM REDDISH SANDY LOAM 2 SP/SM SLIGHTL`( SILTY 3 GRAVELLY SAND GP CLEAN SANDY GRAVEL 4 —H2o SEEPS 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 - COMMENTS ML 5P/SM SLIGHTL`( SILTY I GRAVELLY/ S4Np WAS GROUND WATER ENCOUNTERED? `y�S TRANSITIONS -To S IF YES, AT WHAT r L DEPTH? O P E Beplh to Water AII/er w Monitoring? I I (o 6 G L gale: S62 2 SP CLEAN GRAVELLY SAND B.N. Reading Date, Gross Time Not Time Depth to Water Net Drop PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER TEST nUN BETWEEN FT AND ---- FT PERFORMED BY: FL OP rEC1t, SVCc CERTIFY THIS EST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:5 72-008 (Rev, 4/85) a Flattop Tecliriical Services 14530 Echo Street Anchorage, Alaska 9951E Municipality of Anchorage \ DEPARTMENT OF HEALTH & HUMAN SERVICES 1 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST T.H.#Lf PERFORMED FOR: ALAN KoR LEGAL DESCRIPTION: L2, B2, SECL(/DrD FALL DEPTH PT 1 SM REDDISH SANb%LO/-IM 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 COMMENTS sf /s P1 SLIGHTL`! SILTY, GRAVELLY SAND O�AA���; . ��;e•....,4 . WIN AC�� �THICOO MOORECE - 11589 A�� IIII • _ ______ DATE PERFORMED:' Township, Range, Section: SEC 27� T12i�`{Z SLOPE CITC PI AAI SP C LE'ANf GRAI/ELLY SANp �� SMgI r H%O Sceps ML GRAVELLY SILT 5P/5M SL)GHTLY SILTY GRAVELLY SAND �pp I I I I I LENtSES OF SILTIE&S GROUND WAT ER AND ENCOUNTERED? _ LENSES OF CLEA1K s IF Y S, AT WHAT L MATERIAL DEPTH? 5156 0040W O P E 0 Depthto Water Aller „ Montt Moniloring7 10 r6 R.Q.C. pale: 2 2, Reading Date Gross Time Not Time Depth to Water Net Drop NEE 3 5 9z S:y6:oo 27 a/8 5:4(9:00 23 +H2O S:49:30 27 3/ Elm START 5:52:30 23 3/8 + Nzo .S: Sq', 3o 5: ss :oo 2 /a 23, s/8 17 8 fi H, o 5: S7:oo S S7: 30 2 21 3/y 23 y A _ 5:51: 30 2 21 7/ 0011 Reading Date Gross Time Not Time Depth to Water Net Drop Iz" PRESoA 3 5 9z S:y6:oo 27 a/8 5:4(9:00 23 +H2O S:49:30 27 3/ START 5:52:30 23 3/8 + Nzo .S: Sq', 3o 5: ss :oo 2 /a 23, s/8 17 8 fi H, o 5: S7:oo S S7: 30 2 21 3/y 23 y A _ 5:51: 30 2 21 7/ PERCOLATION RATE (minules/I rich) PERC HOLE DIAMETER 8 r, TEST nON BETWEEN JFT AND 3•15 - _FT _4(4' VJ /It {, PERFORMED BY:L— F ATTOP THC} CERl1FY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DA1 E. DATE: � —'9/2 z 72.001) (Rev. 4/65) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME/-/� Kampf (I.V1I Ac if ✓ie PHONE rl U ❑UPGRADE MAILING ADDRESSI6 16,'5 ��Cil"ti��QQ� �Itic��Q. I I�Dr� LEGAL DESCRIPTION r L.oi' � (310 •lC .2 _� �; i�S �� _ LOCATION ` NO. OF BEDROOMS Uy We DISTANCE TO: /C 4 I Absorption area Dwelling /k't� U f �Uf PERMIT NO. G .3' ,30 t-Z Manufacturer Material No, of compartments rn Lic. capacity in gallons 0 IF HOMEMADE: Inside length •— Width ,_ Liquid depth , O JAZz DISTANCE TO: Well Dwelling PERMIT NO. Tz .1 Manufacturer Material Liquid capacity in gallons o w = DISTANCE TO: Well n !' ro Foundation w ,'2 Nearest lot line �•jU� PERMIT NO. �' 0 (O J w Z F Z w No. of lines Length of each line Total length of lines Trench width 3C inches Distance between lines s CqN p Top of tile to finish grade Material beneath tile � inches Total effective absorption area Qj LU Q Length Width Depth _6/[c PERMIT NO. aF L Type of crib Crib diameter Crib depth Total effective absorption area LU N DISTANCE TO: Well Building foundation Nearest lot line J Jc Class Depth Driller Distance to lot line PERMIT NO. U.1 DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER 4— N v LEGAL PIPE MATERIALS �i4f �l2on7 , (� 303 (4 SOIL TEST RATI G / 93 4 (Ad Lt ,(.-1 INSTALLER cU REMARKS r Lva "i -t �b1 St.UCµl`"f fr{2 Of% fL{T aorJ �— wi lf2o i �oftaQ E3 k�1I o�£f2. eA C k A olnec C APPR VED DATE f'—L/ Lot .2 81oc-K 2 Le<(L ,�d A 72-013 (Rev. 3/78) WATER WELL RECORD STATE OF ALASKA DEPARTMENT OF NATURAL RESOURES Division of Geological 5 Geophysical Surveys Drilling Permit No. _ LOCATION OF WELL (Please complete either la, He or Ic.) A.D.L. No. _ la. Borough Subdivision Lot Block , Ib. 1/a at rs. Section No. Township N U Range ED Meridian mofsof^of o __ S❑ W❑ 1c. DISTANCE AND D�IREC1110N FROM ROAD INTERSECTIONS 3. OWNER OF WELL: Address Street Address and Area of Well Location - 2. WELL LOG Material Type Feet Below Surface q WF, L.DEPTH;(final) f1. ----�'- 5. DATE OF COMPLETION v _ Top Bottom - []Coble tool ,:Q Rotary Driven Dug 0 Auger O Jetted ❑Bored ®Other: -- - "-'� - - - - - 7. USEi; [:] Domestic ❑ Public Supply Industry O Irrigation O Recharge El commerical [J Test Wall ❑ Other: -'- ; - - - - - _ 8. CASING Threaded -,•_E] Welded diam. in toI ft. Depth Weight Ibs./ft. diem, in. to ft. Depth Stickup ft. j�„ v._. _ :-. `'•'. ,. -, '. �.::�.. 9. FINISH OF WELL.: Type: _. — Dlametor� Slot/Mesh Slze: Length:_ Set between _ ft. and _ ft. Backfilling _ Gravel pack .._ 10. STATIC WATER LEVEL: ft. E) Above or Below land surface Date Equipment used: I I . PUMPING LEVEL below land surface end YIELD ft. after hrs, pumping g. p. m. ft. after hrs. pumping g. p. m. 12.GROUTING Well Grouted: Yes ❑ No Material Neat Cement Other: 13, PUM P: (if available) HP Length of Drop Pipe ft. capacity g. P.M. Subm. ❑ Jet ❑ Centrifical Other 14. REMARKS: 16. WATER WELL CONTRACTORS CERTIFICATION: This well was drilled under my jurisdiction and this report is true to the best 1 Contract 15. Water Temperature __.° ❑ F C of my knowledge and belief; License Number Registered Business Nam a Address: Signed: f Oats: f Authorized Representative Form 02-WWR (11/81) Copy Distribution: WHITE -Stole DGGS, PINK -Driller, CANARY- Customer MUNICIPALITY OF ANCHORAGE Department Health and Environmenta' "Irotection 825 Street, Anchorage, AK. .9501 P—L 264-4720 Permit # * * * HANDWRITTEN PERMIT * WELL ANDVf-ON-SITE SEWER PERMIT C(�> Applicant: /Y i ���L{­i'uC7r 75 Mailing Address: _52R Eck Location: Phone Number: '31/ 5-O 90 D Legal Description: L i3 6e(2 /u cl cp)1_--_2�" Lot Size: _ Type of Soil Absorption System Is: Trench: __ Drainfield: s Seepage Bed: Holding Tank: Maximum Number of Bedrooms: Soil Rating(sq.ft/br) %d'(? ff6ic(S7e a -- t �_3 The Required Size of the Soil Absorption System Is: DEPTH �� LENGTH GRAVEL DEPTH WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE _ /CrO -O GALLONS Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. # TWO(2) INSPECTIONS ARE REQUIRED Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 31, 1 9 3 3 I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the esidence is remodeled to include more that 3 bedrooms. Signer: _� Issued by: p i ant Date: SWP/024(1/81) PERFORMED FOR: LEGAL DESCRIPTI 1 2 3 -4 5 6 7 8 9 10 —"11 12 13 14 15 16 17 18 19 20 COMMENTS > SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION TEST 82.5 L. Street, Anchorage, Alaska 99501 2.64-4720 SOILS LOG — PERCOLATION TEST SM mcyr� c�r�av�,1 �m0(f, Gm YYr)I`Cs4-nd\" (�tv -Khan h cob I,CS PERFORMED BY: %,-►ld DATE PERFORMED: ------------ J ii 51 o�rl i�lOG�i� Lc�f2 N --- - WAS GROUND WATER No �L ENCOUNTERED? 0 �s P E IF YES, AT WHAT DEPTH? _ 0I/-) II "i (1'InCl Reading Date Gross a Time Net Time Depth to Water Net Drop d Hz g1z6A3 9`56- 6_ /0 h1;i). •y-6> —i3 ./0 z '25f y b':3 /0:05 7�_/5 /Lo mly'. -v : y () _ , /Q a+6t0 �I�Z51g3 �0 1 �0yryh�r7. y0 1 C1 +li U Z ,5 I -I zsg3 /U: NS lvmlr7 - •,v `lU PERCOLATION RATE CERTIFIED B 72-OOS (6/79) Of (minutes/inch) Y— FT .66789 70 •-111C.— Municipality of Anchorage ,`\:. . i.7". On-Site Water and Wastewater Program a 41•. `'/Iri.iii°' " 7. (907) 343-7904 - , r. I> a f � Certificate of On-Site Systems Approval `zo �ti 's8L95l Parcel I.D. 017-343-10 Expiration Date: ) Ff 3 -125' 1. GENERAL INFORMATION Complete legal description Secluded Hills Block 2 Lot 2 Location (site address) 13265 Badger Lane Current Property owner(s) Alan Bailey & Pamela Rowell Day phone Mailing address 13265 Badger Lane Anchorage, AK 99516 Real Estate Agent Day phone 2. TYPE OF DWELLING: O Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: n Z1/4/413__' _ Received b . A i_ I, A:0, _, Date: COSA to be released to the engineer,unless otherwise requested by the e eer. COSA Fee $ 5a4 Waiver Fee $ Date of Payment ?PM q1 Date of Payment Receipt Number 033646 Receipt Number COSA# O 1 0`/6 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,and regulations in effect at the time of installation. In conducting an adequacy test,I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations.The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year,and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system,nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 745-8200 Address P.O. Box 1807 Palmer, AK 99645 Engineer's Printed Name Steven R Pannone Date 8/8/2018 F Cil 6. DSD SIGNATURE % \r/ K System#1 Approved for ({ bedrooms •S even R. 'annone: •. CE-8149 &/ System#2 Approved for bedrooms �� �s •• '� Disapproved �'k\ ?OFESSIOA 4,- Conditional approval for bedrooms, with the following stipulations: vi 1 ON-SITE , WATER AND 5 WASTEWATER . PROGRAM `C Original Certificate Date: 13_(38 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheel_r If more than 1 septic system is on the lot: COSA Checklist# 1 of 1 Structure served by this system 1 Certificate of On-Site Systems Approval Checklist Legal Description: Secluded Hills Block 2 Lot 2 Parcel ID:017-343-10 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 5/28/1983 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 168 ft. Cased to 168 ft. Casing height(above ground) 12+ in. FROM WELL LOG AT INSPECTION Date of test 5/28/1983 6/21/2018 Static water level U N K ft 128.5 ft Well production 2 g.p.m. 2.1 g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 mL Nitrate ND mg/L Arsenic ND ug/L Date of sample: 7/24/2018 Collected by: PES B. SEPTIC/HOLDING TANK DATA Tank Type/Material S.T.E.P./Steel Date installed 8/6/2018 Tank size 1500 gal. Number of Compartments 2 Cleanouts(Y/N) Y Foundation cleanout(Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) Y Date of pumping NEW Pumper N/A C. ABSORPTION FIELD DATA 6/3-5/1992 0.8 Date installed Soil rating (g.p.d./ft2 orft2/bdrm) GPD/SF System type BED Length 41 ft. Width 21 ft. Gravel below pipe 0.5 ft. Total depth 3 ft. Eff. absorption area 861 ft2 Monitoring tube Y Depression over field N Date of adequacy test 6/21/2018 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 0 in. Water added 600 gal. New depth 0 in. Elapsed Time: 1440 min. Final fluid depth 0 in. Absorption rate >= 600+ g.p.d. N Any rejuvenation treatment(past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed 8/6/2018Size in gallons 250 Manhole/Access (Y/N) Y "Pump on" level at 40 in. "Pump off' level at 36 in. High water alarm level at 45 in. Datum Cycles tested NEW Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: 100+ On ad scent lots 100+ Septic tank/lift station on lot 1 100+ On ad scent lots 100+ Absorption field on lot J 75+ + Public sewer main Public sewer manhole/cleanout 1 25+ Holdingtank 100+ Sewer/septic service line 50+ 100+ Animal containment areas Manure/animal excrete storage areas SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10+ Property line 10+ Absorption field 100+ Water main 10+ Water service line 10+ Surface water Wells on adjacent lots 100+ ABSORPTION FIELD ON LOT TO: Property line 10+ Building foundation 10+ Water main 10+ 10+ Water Service line 10+ Surface water 100+ Driveway,parking/vehicle storage Curtain drain 50+ Wells on adjacent lots 10 F. COMMENTS G. ENGINEER'S CERTIFICATION +1" I certify that I have determined through field inspections and of 0j.- ,4 .•1' # review of Municipal records that the above systems are in 0* ,' ;- /= '.�'r! conformance with MOA COSA guidelines in effect on this date. ''. . / Engineer's Printed Name Steven Pannone i":Sri 'k '0 a n n o n e. CE .8149 • j Date 8/8/2018 1#lgs ., 'Ar A `tFROFEs9 P COSA canary sheet_2-6-15.doc t„i\ , A17‘) 4 • h ' 4.I° ,' eft, ��a6 a �1,1� • ' ir. �e �� , 1` . 0. �d • / s3' - ,I 4• J .o• 6 aw }1- • f ,it ,,,i, fpr 1 .1 ,p 1 A� Dbe' ' / 1 o11/ / �� / ,��6 -- � i , / �' f `` ��� - ASBUILT SEWARD & ASSOCIATES LAND SURVEYING 694-0829 I HEREBY CERTIFY THAT I HAVE SURVEYED THE SCALE: FOLLOWING DESCRIBED PROPERTY: __ �: OF A( a s��i�'ac ,i-7 .5" .c1 to>z',/.�,�."z • r DATE �e.11fQ" S tf AND THAT NO ENCROACHMENTS EXIST EXCEPT AS /6/ ' s fr -� .;� '•.4" i , INDICATED. IT IS THE RESPONSIBILITY OF THE e t : .H P•k 4. :Y OWNER TO DETERMINE THE EXISTENCE OF ANY GRID: i •'`' ;gl� EASEMENTS, COVENANTS, OR RESTRICTIONS z93,7 r „ WHICH DO NOT APPEAR ON THE RECORDED SUBDI- — 0O Duane Mark $c war .. v VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD FB'/ �2� �°..' 1�s t•3 .. ���' .r ANY DATA HEREON BE USED FOR CONSTRUCTION �A' ,� ' � ',�'°' OF FENCE LINES, OR FOR ESTABLISHING BOUND- DAWN, h,� ;+*'' ARY LINES. �/ MUNICIPALITY OF ANCHORAGE ° DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services Ak On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # c/ 7 — 3 y 3 - 1 C 1. GENERAL INFORMATION HAA # _ 1�� 11�':I •(-','a, •� Complete legal description Loi: 2: B.Lock 2; Se.ce.uded Fiat. s Location (site address or directions) 13255 Badge, lAncno•Lage., Lane. A, Property owner JUheph 9 Cnjcti3 Buka4 y Day phone 345-0316 Mailing address C/O REAL ESTATE SUPPORT SVS. 8200 Fiur?bo?dt Ave.. S. SuU'e 204 M nneapc,L s, MN 5;,431 Lending agency Day phone Mailing address Agent Day phone Address Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: 4 1AUISICIPAUTY OF ANCHORAGE DiVIS10N 3. TYPE OF WATER SUPPLY: S�t�WE�pAt.SERVICES 28 1996 JON Individual well Community well R�C� it `V JD Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) From MOA N21 5. 6. 0 STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm S & S ENGINEERING age ner oop oa o. —Phone Address Eagle River, Alaska 99577 Engineer's signature DHHS SIGNATURE KApproved for bedrooms. Disapproved. Conditional approval for Additional Comments Mir Date q 6. ���0 F qC�1 .fiH •.a.✓n .4 .' - -' .' 4 y. Vi.. � MSI j{ ;o ROURi C. COWAN f f +4 �� tel' •.'�J � .. • Y y V'i. �Z`� bedrooms, with the following stipulations: Date 7Zs The Municipality of Anchorage Department of Health and Human Services (DFiHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of hornes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 1/91) Beck MOA X21 Municipality of Anchorage ��'I'Rp ��'°���ry DEPARTMENT OF HEALTH & HUMAN SERVIGq, SOP Environmental Services Division ��// r.PV woe 825"L" Street, Room 502 • Anchorage, Alaska 99501 • (9073e1J44 Health Authority Approval Checklist LOT k,2-ocvc D- S6"v"')/""-P OI7 3H3 Legal Description: _ _ Parcel I.D.:__ A. WELL DATA Well type If A, B, or C, attach ADEC letter. ADEC water system number Log present Q" y f- S Date completed — 3' / '-X V ( S 7 Total depth / G ^ Cased to / 3 Casing height (above ground) Sanitary seal (b N) y E f _ Wires properly protected O/N) YE S Date of test Static water level Well production FROM WELL LOG s-/ 3L 3 (1/4 WATER SAMPLE RESULTS: Coliform 0 Nitrate Date of sample: t 7 ` q 6, g.p.m. AT INSPECTION (0 �a-u/ q& 1 )L / • S g.p.m. 0 1 / Other bacteria P Collected by: S & S ENGINEERING 17034 Eagle RI vex Loop Ituad No. 204 ERgte River, Alaska 99577 B. SEPTIC OLDING TANK DATA Date installed s/ 63 � 6/"ank size 1 u v o s vNumber of Compartments °� Cleanouts 611) y S Foundation cleanout S Depression (Y6) High water alarm 6/1) 'Y ff -f Date of Pumping_ a Pumper 4 f 0 e M E S t'ovi c e S C. ABSORPTION_ FIELD DATA Date installed 6 /c/ Soil ratingg.p.d./ft2 or ft2/bdrm) 0.9 _ System type 86-0 Length _Width ci- Gravel thickness below pipe Total depth Effective absorption area Monitoring Tube present$/N) Yk 5 Depression over field (YX@ 0 Date of adequacy test G rI o `� 6 Results (Pass/Fail) P 4 S ! For _ y bedrooms Fluid depth in absorption field before test (in.); A IL Fluid depth p ,a Y (ins.) Minutes later: 0 Peroxide treatment (past 12 months) (Y/N) f" ° Fi Y Immediately after III 7gal. water added (in.): 0/1 Y Absorption rate o. o g.p.d. ` " ° i� ✓ If yes, give date D. LIFT STATION Date installed (o / q Z Size in gallons _ Manhole/Access 0)/N) Y 4Y S "Pump on" level at* "31 High water alarm level at* Cycles tested 3 E. SEPARATION DISTANCES 37rr r0(2 "Pump off' level at* a 7 *Datum r 0 N K AV rY-o,7 SEPARATION DISTANCES FROM WELL ON LOT TO: Le u olding tank on lot /00 r -f ; On adjacent lots Absorption field on lot J 0 o ��- Public sewer main ry 1/f Sewer /septic service line a S �-/- 1 0 0 1 -7f - On adjacent lots /00 /'` Public sewer manhole/cleanout N 1,4 Lift station / b o / --/.- SEPARATION DISTANCES FROM SEPTIC OLDING TANK ON LOT TO: Building foundation S -/- Property line /49 t Absorption field Water main/service line :) S * Surface water/drainage /Oo r"/-- Wells on adjacent lots /O J 00 1 4 - SEPARATION SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Building foundation ;L '-4 Property Line 0, S Water main/service line r �d r Surface water J ° o -4-Driveway, parking/vehicle storage area -l- Curtain drain /U Or rt aN 0 w ;v Wells on adjacent lots 1 6 e F. ENGINEER'S CERTIFICATION 1 certify that I have determined thru field inspections and review of Municipal in conformance with MO^�guideliZ:-. f ect on this date. Signature -- Engineer's Name 6V `t r C - Cs rV 14 �✓ Date /� C HAA Fee $t� Waiver Fee $ _ Date of Payment /4 �/ �O Date of Payment Receipt Number�Receipt Number Rev. 8/95 OSS: haa.wk.doc �dstr�bo� s are �0 1 ROBERT C. COWAN Jor CE 8801 7 It MUNICIPALITY OF ANCHORAGE a}j • '^ DEPARTMENT OF HEALTH & HUMAN SERVICES M Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING. Parcel I.D.# 01 - IIA -2) - \C 1. GENERAL INFORMATION Complete legal description Lo f 219 8 to k 2, Sec (cedecC fii is S I D Location (site address or directions) 1.3,06-S" Sctager Inane Property owner _A(an � Ma.rtha korni Day phone 3yS-610,T _ Mailing address 1-306.5- 1361 e /.,ane. f4nrJ�orape, �}G� 995 Lending agency Norwe�f Mor><gag2 Day phone 276- H2Sa Mailing address-24TO_ Denall�;SuJe- IY06, AAcAora5e4 Ak 99S' \\ Agent Mal) (cvrr i 4#J Real 1=sfufe Day phone 27y " yyyy Address 836 C- 15-", Ave.,f4nchoc Te Ac 995*i c� Unless otherwise requested, HAA will be held for pickup. 1 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site V-1 Holding tank _ Community on-site _ Public sewer _ NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA U21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I furtherverify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Fkaf Ter -b i,cQ( Secvi «r Phone 3yS-13sS Address _1 `1530 Echo Amr-honVe Ak 9951 Engineer's signature Date Tunc 9, 199? 6. DHHS SIGNATURE Approved for r%A=ny? Disapproved. Conditional approval for Additional Comments v- THEODORE F. MOORE; CE - 3589 ,• 1' A7 bedrooms. bedrooms, with the following stipulations: Date The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 1/91) Back MOA 421 Municipality of Anchorage Department of Health & Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Lot 2, &0c 1'c 2, Sed"ded *11f Parcel I.D. 611 / 31/x-- /6 A. WELL DATA Well type Prt'va �� If A, B, or C, attach ADEC letter. ADEC water system number hlr A, Log present (Y/N) Y Date completed 5/2/63 Driller Ma4nulon DrtNrn�, Total depth 16 e Cased to I GB Casing height S7 " Sanitary seal (Y/N) Date of test Static water level Well flow Pump level FROM WELL LOG 2 SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot los') Absorption field on lot 155' Public sewer main A A. Sewer service line 80' WATER SAMPLE RESULTS: Coliform O co/ /(001"17-LNitrate Date of sample: `// !6 /9 Z Wires properly protected (Y/N) Y 11 AT INSPECTION o z ty /46-/92 M a:2 /3/' m O 9 g.p.m. ! r 3 g.p.m. < r'ius T:r � l 6B < w c� .; On adjacent lots > too' On adjacent lots > /0,' Public sewer manhole/cleanout N' 6. Petroleum tank Mane observed( o. lr,q Other bacteria Collected by: Flaft Tech Svc B. SEPTIC/MOLDING TANK DATA 6 f N /92 ,5-00 yal I Date installed 5"1,? 1 /83 Tank sizeIGS a/ Compartments 2 Cleanouts (Y/N) High water alarm (Y/N) Date of pumping Foundation cleanout (Y/N) Y Depression (Y/N) N 4114, Alarm tested (Y/N) N. A. /92 Pumper 19 t -- SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot I 0 To property line Surface water/drainage > l00' _On adjacent lots } 100' Foundation 20' bsorption field 35 Water main/service line—6 0 72-026 (Rev. 7191) Front CONTINUED ON BACK PAGE C. LIFT STATION Date installed 61Y 19e Manufacturer—renco / Ilnchot iant- Size in gallons 5'<>U Manhole/Access (Y/N) Vent (Y/N) 1' r "Pump on" level at High water alarm level 37. Meets MOA electrical codes (Y/N) Y SEPARATION DISTANCE FROM LIFT STATION TO: Well on lot f "-�o' On adjacent lots D. ABSORPTION FIELD DATA Y "Pump off" level at 2y1`._ . Cycles tested 1 tero Surface water Date installed /�� /9 _ Soil rating 0. 89A!( /Ft" System type _ ;3e -o( Length y/' . Width —2 t J Gravel thickness 0. 76-' _Total depth 31 Total absorption area 85-1 Q Cleanouts present (Y/N) _ 2 Mom for retyv Depression over field (Y/N) N _ Date of adequacy test N/A Newj Results(pass/fail) NIA CNfor H bedrooms Peroxide treatment (past 12 months) (Y/N) N If yes, give date NIA SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot ISS' On adjacent lots > lc'o' Property line__ To building foundation SS' To existing or abandoned system on lot a 30' On adjacent lots > 30 Cutbank N-4. Water main/service line ? 5'0' Surface water > «>o' Driveway, parking/vehicle storage area > too ' Curtain drain None Seen E. ENGINEER'S CERTIFICATION 1 certify that l have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. I�.• ».rs ;Z .p 7 il4 Signature J� n°-®`�e r • a 49T14,;SYS Engineer's Name --Th eodor-e Moor1' �••••••••�•••••••.,.•��••''••••».. Date - T1992� ...... .......�1:....rn:: �t n e % �a .%THEODORE F. MOORE : � CC -3589 •,' A� •• .// 40 HAA Fee $ .�_%b Date of Payment _ _ Receipt Number a 72-026 (Rev. 3/91) Back MOA 21 Waiver Fee: $ — Date of Payment Receipt Number t1 PA lc 0 l f, (-).7- Time -). Time Time Time APPLII Ni PILLS OUT UPPER HA ONLY Property Owner ;!�(-, .; ';= / �,� �} �`-)r : <. =:? �.. -..7 =. •., 1 !:_> - Phone Mailing Address ',-� ��J;: ��/r. '- .,j - Zip Code i Inspector Buyer Inspector Address Field Notes: Zip Code Lending Institution 1l FY l� Phone Address_%�/� ,� �; �• `',-) Zip Code Realty Co. & Agent e-.-_> �� /'f; h7; _ ;•• �- % (_,-T ,' :�_ i; •J/�). /,+,�-_!-',>/ Phone Address RECEIVED Zip Code r Legal Description APPROVED BEDROOMS ----- Street Location Type of ,,Residence Ingle Family ❑ Multiple Family No. of Bedrooms - 11 Other Date Sewer Installed Well To Absorption Area �„�, Well Log Receivedly S- I Water Supply Well to Tank1 Qom° Septic Tank Size �`tJ IlfNndividual ATTACH WELL. LOG. A well log is required for all wells drilled since June 1975. 1 ❑ Community For wells drilled prior to that date, give well depth (attach log if available). ❑ Public Utility _ Sewer Disposal 19-- ndividual Year Individual Installed: ❑ Public Utility When Connected to Public Utility: _.-- ❑ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. t1 PA lc 0 l f, (-).7- Time -). Time Time Time Time Date Date Date Date ( e Inspector Inspector Inspector Inspector Field Notes: MUNICIPALITY OF ANCHORAGE 1l FY l� DEPT. Or HEALTH 7< ENVIRONMENTAL //PROTECTION 6-\i G 16 i9z. RECEIVED APPROVED BEDROOMS 'CONDITIONS OF APPROVAL ( ) DISAPPROVED ` ( ) CONDI 10 AL AlP/PR�O�VAL' DATE _ G Soils Rating Date Sewer Installed Well To Absorption Area �„�, Well Log Receivedly S- I Well to Tank1 Qom° Septic Tank Size �`tJ 72 023 (8182) ALASKA HUMOf1f MAL COMROL SRUICCS, InC. Engineering 6 Enuironmenlal Sludies Supplemental Soils Information. Subdivision `) C.� 1� C� '► )1 ���J Block LQ� z- LOT LOT LOT LOT T H T H T H T FI �-_--�—, r VL N(o Pn4 (FEET) i (FEET) 1 II 1 1 1 2- CAM 2 7. 2 3 3 3 3 4 4 4 4 V u puU e' 5 v v v c„ r 5 )�(�J 5 5 p o v v v� '- eW Si`"' 6 6 6- 6 cv d 0 j ovvpp 7 0 �.� v o 7 7 7- e G M a� g 8- 9 �- CV6ag i 9 9 10 10 I, 10 I 10 - 11 11 11 11 12 12 12 12 13 13 13 13 14 14 14 14 15 15 15 15 16 16 16 I 16 17 17 17 17 18 i 18 18 18 19 L 19 19 19 z°.TNI 2° 20. 20 1200 Wesl 33rd Auenue. Suite E • Rnkroge, Rlosko 99503 • 907) 2761361