MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP241224
Work Type: Septic Upgrade
Tax Code Number: 01129108000
Site Legal Address: SEAVIEW HEIGHTS BLK 1 TR 3 G:2323
Site Mailing Address: 5950 W DIMOND BLVD, Anchorage
Owner: PAULSON ROBERT A & MARJORIE S
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Effective Date
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
t 11 t
�.rrt��rt
t)eI)artill eIII
8/20/2024
8/20/2025
89629
Q Disposal Field CI Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
5
Received By: 5 VIED ' C� Gi Date:
Issued By: Date:
MUNICIPALITY OF
4
Community Development Department
Development Services Division
On -Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON -SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 011-291-08
Property owner(s) Robert & Marjorie Paulson Trusts Day phone _
Mailing address 5950 W Dimond Boulevard, Anchorage, AK, 99502
Site address 5950 W Dimond Boulevard
Legal description (Sub'd., Block & Lot) Seaview Heights, Block 1 Tract 3
Legal description (Township, Range & Section)
Lot Size - 89,629 _Sq. Ft. Number of Bedrooms 5
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(Z all that apply)
Absorption Field
FX-1
Initial El
Single Family (SF)
(w/wo ADU)
Septic Tank
N
EX] Upgrade ❑
Duplex 0
(D)
Holding Tank
0
Renewal D
Multiple Dwellings D
Privy
❑
(SF and/or D)
Private Well
D
Water Storage
El
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 05q-6- Waiver Fees:
Date of Payment: 11-Z'61-L 11 Date of Payment:
Receipt Number: 10316 Receipt Number:
Permit No. 0-519 Z 9 / 2 Waiver No.
Permit App_'-'- '. :'c ;
July 25, 2024
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Seaview Heights, Block 1 Tract 3 – 5950 W Dimond Boulevard
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot has an existing 5-bedroom home on the property, so we are submitting
this permit application for the construction of a new septic system. The attached site plan identifies
the location of the home as well as the existing well and septic location. No conflicts exist between
this proposed system and any other well or septic system, whether on this lot or adjacent lots.
The ground surface on the lot slopes moderately toward the road near the front of the lot, and also
drops off steeply at the bluff back of the of the lot, but near the middle the slopes are much milder.
It is in that flatter area that the new septic system is located. There are no slopes greater than 25%
within 50 feet downslope of the new site. Contours are shown on the site plan showing the grade
and direction of flow. Stormwater drainage will not impact this septic system. The new trench will
be constructed parallel to the slope as much as possible.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all
wells and surface water, and more than 5’ away from the septic tank. Please refer to the attached
test hole logs, plan and profile pages for the septic design. If this design is followed, there will be
no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241224, Curtis Townsend, 08/20/24
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
1"=50'
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
2CO
SEAVIEW HEIGHTS, BLOCK 1 TRACT 3
FEET
0 50 100
SEPTIC PLAN
7/24/2024
EXISTING
5-BDRM HOME
GA
R
A
G
E
WELL w/ 100' RADIUS
EXISTING SYSTEM
LOCATE AND DECOMMISSION PER CODE
NOTE: RECORDS INDICATE 3 TRENCHES
OF UNKNOWN DIMENSIONS
LOCATE FULL LENGTH OF EACH TRENCH
TH#1
170
170
160
150
140130
160
150
CO
CO
MT
MT
65' LONG x 5' WIDE, 4' EFFECTIVE
DEPTH ABSORPTION TRENCH
NEW 1500-GAL SEPTIC TANK
PROVED 2CO BEFORE TANK
OR NEW FOUNDATION CO
2CO
ESTIMATED LOCATION
OF NEIGHBORING WELL
w/ 100' RADIUS
ESTIMATED LOCATION
OF NEIGHBORING WELL
w/ 100' RADIUS
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241224, Curtis Townsend, 08/20/24
SEAVIEW HEIGHTS, BLOCK 1 TRACT 3
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
DESIGN FACTORS:SYSTEM REQUIREMENTS:
750 GPD PEAK FLOW
PERK RATE: 2.2 MIN/IN
APPLICATION RATE: 1.2 GPD/SF
5' WIDE TRENCH SYSTEM
1500-GAL SEPTIC TANK
BOTTOM OF TRENCH: 5' 6" BELOW GRADE
FLOW LINE ELEVATION: 1' 6" BELOW GRADE
750 GPD / 1.2 GPD/SF / 5' WIDE * 0.50 RED FACTOR [4' DEEP] = 62.5 LF TRENCH REQUIRED
(65 LF SPECIFIED)
7/24/2024
5'
1'-6"
1'
4'
6"
PROVIDE ADDITIONAL FILL TO
ACCOUNT FOR SETTLEMENT
4" PERFORATED PVC (HOLES DOWN)
DRAINFIELD ROCK
GEOTEXTILE FABRIC
2" FOAM INSULATION
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241224, Curtis Townsend, 08/20/24
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
DEPTH
(feet)
TEST HOLE 1
DATE READING START TIME NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERCOLATION RATE: (MIN/INCH)
(inches)(inches)
DATE OF MONITORING
WAS WATER ENCOUNTERED?
DEPTH TO WATER AFTER MONITORING
IF YES @ WHAT DEPTH?
2.2
7/12 1
2
3
4
5
6
SM (SILTY SAND)
Professional Engineers Stamp:
NO
SEAVIEW HEIGHTS, BLOCK 1 TRACT 3
7/12/2024 011-291-08
LUKE DUFFY
11:15 1 0
16
12:07
1' OB
6:58
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
PERC TEST LOCATION
TECHNICIAN: J.OPHEIM
7 0
16
-
NONE
7/19/2024
COMMENTS:
SITE PLAN
6 0
16
USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED
7/24/2024
SP (GRAVELLY SAND)
11:22 1 0
1610 6 9
16 5 9
16
11:35 1 0
1610 6 3
16 5 3
16
11:45 1 0
1610 6 1
16 5 1
16
11:56 1 0
1610 6 0
16 5 0
16
1 0
1610 5 12
16 4 12
16
7 12:18 1 0
1610 5 15
16 4 15
16
8 12:31 1 0
1610 5 10
16 4 10
16
9 12:43 1 0
1610 5 11
16 4 11
16
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241224, Curtis Townsend, 08/20/24
\\DAM
AND
N D --
d'
to
Tract 4 0
0
0
a
Tract 3
89,629 s.f.
1 19.95'
S 89'50' 18
M
o Tract 2
0
0
Z
Lot 2
19.0'
1.2' x 5.7' CANT
SEPTIC CRIB
SEPTIC PIPE
ASPHALT ;
PAVEMENT*•
HOUSE DETAIL
Scale: 1 " = 30'
RAILROAD TIES
(TYPICAL)
NOTE: NO EASEMENTS ARE SHOWN ON THE RECORD PLAT.
PLOT PLAN ___ AS BUILT _X_ SCALE _1_ 100_ GRID SW 2323 Project No J24-0281A2
Lang & Associates, I n C Alas. P.O. Box 214000Op
Anchorage, Alaska 99521-0005
Professional Land Surveyors keno 592-64y6 OF q o 0
ken®Ian surve com � � Q
O
ionathan®lanasurvev.com v .-X-i"
I hereby certify that I have surveyed the following described property:
TRACT 3, BLOCK 1, REPLAT OF SEAVIEW HEIGHTS SUBDIVISION (Plat No. P-162D)
Anchorage Recording District, Alaska, and that the improvements situated thereon are
within the property lines and do not encroach onto the property adjacent thereto, that
no improvements on the property lying adjacent thereto encroach on the surveyed
premises and that there are no roadways, transmission lines or other visible
easements on said property except as indicated hereon.
'(It
Dated this the _ZS____ Day of _ M 0--------- � at Anchorage, Alaska
p�OFESS10NA �Nvo
It is the responsibility of the owner to determine the existence of any easements,
covenants, or restrictions which do not appear on the recorded subdivision plat.
State of Alaska AECC963
Mayor
Development Services Department
Building Safety Division
On -Site Water a& Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, AK 99507
Ww .muni.oro/onsite
(907)343-7904
Pump Installation Log
Well Drilling Permit Number: SW
Date of Issue: _
Parcel Identification Number: (A�1��C £ p )OL ER, �q c�5oti(
Legal Description Property Owner Name & Address:
S 151. V I r4w F1 g"n, [?4J1_San
pe)('h&eAgf 1 A K k'454)Z_, 00q
Pump Installation Date: Mary J7`4 -/
I�Pump Intake Depth Below Top of Well Casing: r,00 feet
Pump Manufacturer's Name: (� r r>;S iae VAS l
II Pump Model: / U O G 31 1 g S 2-\
Pump Size i hp
Pitless Adapter Burial Depth: l O feet
Pitless Adapter Manufacturer's Name: /
Pitless Adapter Installer: 1
Weil Disinfected Upon Completion? I es ❑ No
Method of Disinfection: C lao yl iy 8171 1 $ fTT5
11 Comments:
11 Pump Installer Name:
fq11EhC4Aq w21r dP�n++' Sgeusc£
Attention: The pump installer shall provide a pump installati4n log to the DSD within 30 days of pump installation.
u�
5. LEGAL DESCRIPTION
DATE RECEIVED �
INSPECTION
APPOINTMENTS
)�
TIME
NUMBER OF,BEDROOMS
TIME
TIME
DATE
EJ Two O Five
DATET'E
A Three ❑ Six
7. WATER SUPPLY
INDIVIDUAL*
* ATTACH WELL LOG. A well log is required for all wells drilled
&,
LQ -a --Sc Cna
INSPECTOR
depth (attach log if available.)
INSPEC OR
v A �
INSPECT
��ll^
e6 INDIVIDUAL/ON-SITE**
MUNICIPALITY OF ANCHORAGE
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION DEPT. OF I -/•d.11 i c
825 L Street - Anchorage, Alaska 99501 ENVIRONME;NIAL r..:.a'-CTION
•
ENVIRONMENTAL SANITATION DIVISION MAY 3 0 1980
Telephone 264-4720
pp�
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEV4 ':i{ L �JLi1�L 3J
DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing.
1. PROPERRTJTYOWNER
I
�-/
PHONE
MAILING ADDRE✓
PROPERTY RESIDENT (If different from above)
PHONE
2. BUYER
PHONE
MAILING ADDRESS
_�vt-icy-->7—>X
n
e
3. LENDING INSTITUTION
_
PHONE
MAILING ADDRESSJ..p
�q 0
4. REALTOR/AGENT
PHONE
MAILING ADDRESS
5. LEGAL DESCRIPTION
0� '-4- 3)
STREET LOCJATION
6. TYPE OF RESIDENCE
NUMBER OF,BEDROOMS
SINGLE FAMILY
El One ❑ Four ED Other
EJ Two O Five
MULTIPLE FAMILY
A Three ❑ Six
7. WATER SUPPLY
INDIVIDUAL*
* ATTACH WELL LOG. A well log is required for all wells drilled
O COMMUNITY
since June 1975. For wells drilled prior to that date, give well
O PUBLIC UTILITY
depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
-�
e6 INDIVIDUAL/ON-SITE**
�—YEAR ON-SITE SYSTEM WAS INSTALLED.
E] PUBLIC UTILITY
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010 ,(R/ev. 6/79) rlec 1cr1J Tattle.
JV&LV�7—y/-A- v
M
72-010 (Rev. 6/79)
THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE
❑ SINGLE FAMILY
❑ MULTIPLE FAMILY
NUMBER OF BEDROOMS
❑ ONE ❑ THREE ❑ FIVE
❑ TWO ❑ FOUR ❑ SIX
❑ OTHER
2. WATER SUPPLY
❑ INDIVIDUAL
❑ COMMUNITY
❑ PUBLIC UTILITY
Connection Verified
PERMIT NUMBER
DEPTH OF WELL
DATE DRILLED
LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM
❑INDIVIDUAL/ON -SITE
ED PUBLIC UTILITY
Connection Verified
PERMIT NUMBER
DATE INSTALLED
INSTALLER
❑Septic Tank or ❑ Holding Tank
Size: If Tank is homemade
give dimensions:
SOILS RATING
TYPE OF TANK
MANUFACTURER
TOTAL ABSORPTION AREA
MATERIAL
4. DISTANCES
WELL TO:
Se/Holding Tank
ptic
Absorption Area
Sewer Line
Nearest Lot Line
Absorption Area to nearest Lot Line
5. COMMENTS
APPROVEDFOR BEDROOMS
❑ CONDITIONAL APPROVAL (letter must accompany certificate)
❑ DISAPPROVED
DATE
V VT&*4
BY
/Voro
M
72-010 (Rev. 6/79)
r�E REID ENVIRONMENTAL ENGINEERING MUNIDEPT. v of ANCHORAGE
1 DEPT. Cf '.
2 SRA BOX 1584R ENVIRON:: -TION
ANCHORAGE, ALASKA 99507
(907) 344-1205 `,i;,•�,( %��Cj�
276-1361
R CEIVLO
May 19,1980
Mrs A.T. Van Dolah
5950 W Dimond Blvd
Anchorage AK 99502
Subdivision- Seaview Heights Block 1 Lot 3
The system tested is a series of three trenches of unknown length and depth.
The system was installed by Bell Plumbing in 1975. Burial depth was 16 to 20
feet.
During the three hour 10 minute test a total of 1030 gallons of water was
dumped into the system. There was no evidence of backing up in the septic
tank, There was no evidence of surfacing water over the area of the installation.
As the site is adjacent to the Sand Lake gravel pits, it must be assumed from
this and from the owners information that the system was properly installed.
Washed gravel was used in the trenches.
The system is adequate to serve a three bedroom home.