Loading...
HomeMy WebLinkAboutSEACLIFF BLK 1 LT 16MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP231361 Work Type: SepticTank Upgrade Tax Code Number: 01122117000 Site Legal Address: SEACLIFF BLK 1 LT 16 G:2424 Site Mailing Address: 5308 SHORECREST DR, Anchorage Owner: ROTH JEANNE M Design Engineer: FIRST WATER CONSULTING This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft Total Bedrooms: �1��ent L)eparttnent 10/27/2023 10/26/2024 29900 ❑ Disposal Field Z Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: E �1��' J, (-Uc Issued By: Date: 4 Date: ( - 2 Z 3 MUNICIPALITY OF ANCHORAGE Development Services Departments' Phone: 907-343-7904 -On-Site Water & Wastewater Section Fax. 907-343-7997 ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 011-221-17 Property owner(s) JEANNE M ROTH 1994 TRUST Day phone _ Mailing address 11150 SUKDO WAY, ANCHORAGE, AK 99515 Site address 5308 SHORECREST DRIVE, ANCHORAGE, AK 99502 Legal description (Sub'd., Block & Lot) SEACLIFF BLOCK 1, LOT 16 Legal description (Township, Range & Section) Lot Size 29,900 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) - Absorption Field ❑ Initial ❑ Single Family (SF) El (w/wo ADU) Septic Tank El Upgrade X Duplex (D) El Holding Tank ❑ Renewal El Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: .02Z 5- Date of Payment: /2&Oy2?j Receipt Number: 01022.5 Permit No. 05j023 )� h 1 Waiver Fees: Date of Payment: Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / firstwaterAK@gmail.com ! !! October 23, 2023 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: SEPTIC TANK UPGRADE PERMIT LEGAL: SEACLIFF BLOCK 1, LOT 16 The unknown existing septic tank was scoped and found to be of concrete material and the integrity compromised with many roots. Therefore, the owner has requested that we obtain a septic permit to upgrade the existing aged concrete septic tank on the above referenced lot. We propose to install a 1500-gallon HDPE tank per the attached design to serve the existing 4- bedroom residence. No groundwater was noted in the MOA on-site file, but if groundwater is encountered during installation an epoxy coated steel septic tank may be required. The lot and area are served by public water. The design will not impact any of the neighboring properties. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231361, Curtis Townsend, 10/27/23 N 48 ° 1 0 ' 00" E 29 1 . 7 4 ' S 3 5 ° 0 4 ' 3 0 " W 4 B R HO U S E LOT 16 30,017 sq. ft. CA NTI LE VER D E C K ASP H A L T DRIVE W A Y F ENC E L O T 1 5 30' REBAR SH E D SH E D 1 0 ' U T I LI T Y E A S E M E N T LOT 17 43. 0' 10 . 0' 21. 0' 10 . 0' 2.0 ' 26 . 0 ' 66. 0 ' 26 . 0' S H O R E C R E S T D R I V E 30' O V E R H E A D U TILI T Y LI N E E O E O E O E O E O E O E O E O S H E D U T I L I T Y P O L E C O N C R E T E CAN T I L E V E R 1 4 . 7 ' A 8 0 . 0 0 ' R 3 5 0 . 0 0' 1 9 . 5 ' FIRST WATER CONSULTING SEACLIFF BLOCK 1, LOT 16 DESIGN DETAILS: AREA SERVED BY PUBLIC WATER.NO WELLS WITHIN 200' OF PROPOSED SEPTIC TANK Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231361, Curtis Townsend, 10/27/23 — — —SHORECREST DRIVE— — O Co m M EO AVQ 0.0O1 -EO-EO X , Eo REBARr. _ Eo �ER350.00 — -EO EO UTILITY 10' UTILITY EASEMENT peo eH \o UTILITY LINE POLE SEPTIC STANDPIPE I I I Co I Co I I N LOT15 W O 0 0 00 ASPHALT DRIVEWAY II GO�GRESE::. 6do 6 0 0. 2-STORY N FRAME HOUSE 0 LOT 16 30,017 sq. ft. N 620 3, 3q„ UNSUBDIVIDED EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED SUBDIVISION PLAT (P-659) ARE NOT SHOWN HEREON. THIS DOCUMENT DOES NOT CONSTITUTE BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THATA SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. UNDER NO CIRCUMSTANCES SHOULD ANY OF THE DATA HEREON BE USED FOR CONSTRUCTION OF FENCES, IMPROVEMENTS, OR FOR ESTABLISHING PROPERTY BOUNDARIES. THIS SURVEY REPRESENTS A MORTGAGE LOCATION SURVEY PREPARED IN ACCORDANCE WITH THE ASPLS MORTGAGE LOCATION SURVEY STANDARDS. 7Z SHED THIS MORTGAGE LOCATION SURVEY SHOULD ONLY BE USED FOR A SINGLE PROPERTY TRANSACTION. RE -USE OF THIS DRAWING BY THE ORIGINAL CLIENT OR BY OTHERS, FOR ADDITIONAL USES ATA LATER DATE WITHOUT EXPRESS CONSENT OF THE SURVEYOR IS A VIOLATION OF FEDERAL COPYRIGHT LAW. UNLESS GROSS NEGLIGENCE IS DISCOVERED, THE LIABILITY EXTENT OF THE PREPARER SHALL BE LIMITED TO THE AMOUNT OF FEES COLLECTED FOR SERVICES IN PREPARATION OF THIS PRODUCT. 0 15, 30' LOT 17 OF *: 4 9 TH ................ ......... .... �'• B u Saliz : o LS-14837 rl f O FES\\O� \_ AS -BUILT I HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY: LOT 16, BLOCK 1, SEACLIFF SUBDIVISION ANCHORAGE RECORDING DISTRICT, ALASKAAND THAT THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS EXIST EXCEPTAS INDICATED. DATED THIS 2nd DAY OF OCTOBER, 2023, AT ANCHORAGE,ALASKA. FIXED HEIGHT, LLC C.O.A.122554 Land Surveying Services 907.290.8949 225 VV 23rd Ave., Anchorage, AK 99503 WWW.FIXEDHEIGHTCOM JOB # 23154 I NO CORNERS SET THIS DATE I SCALE 1" = 30' MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION (00*_ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME ,,/J (Lr�P✓� e PHONE _ EW DbPGRADE MAI LIJLGADDRESS LEGAL DESCRIPTION LOCATION NO. OF BEDROOMS DISTANCE T0: Well Absorption area Dwelling PERMIT NO. v a ZQ Manufacturer Material No. of compartments wF CID Lie. capacity in gallons IF HOMEMADE: Inside length - Width Liquid depth DISTANCE TO: Well Dwelling PERMIT NO. _j�z = Manufacturer Material Liquid capacity in gallons 0 w= DISTANCE TO: We Foundation Nearest lot line PERMIT NO. J LL z No. of lines Lengt f each line Total len h o; lines Trencl},idth Distance@tween lines H z ¢ inches N H Top of tile to finish grade 1 Material beneath tile Total effective absorption area inches Length Width Depth PERMIT NO. Lu C7 Q I— as w Type of crib Crib diameter Crib depth Total effective absorption area LU DISTANCE TO: Well Building foundation Nearest lot line J Class Depth Driller Distance to lot line PERMIT NO. J Lu DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS 3c> 3 U049 SOIL TEST RA 1 G /M INSTALLER REMAR I I APPROVE LEGAL a, &I s �-V IJ�yrwcV. J//o/ f V Dev� partment fHealthand Environmenta Protection 825 Street, Anchorage, AK. '-;a501 . # # # 264-4720 # � #tc�'<,�1c�1� !�- �. t HANDWRITTEN PERMIT , Permit # ON-SITE SEWER PERMIT-LAPcJ---\1A-CLC y Applicant: /�/Gt'c� C-llo_11-i2Z Mailing Address:,<2S0c� JkIeG.��f>` Location: ,�, /� �P %J%d✓. Phone Number: �,4g- 65FS.5, Legal Description: 4G1ilr-e- Lot Size: '�/cl4 Type of Soil Absorption System Is: G Trench: ;7Drainfield: _ _ Seepage Bed: Holding Tank: Maximum Number of Bedrooms: Soil Rating(sq.ft/br) /00 The Required Size of the Soil Absorption System Is:' � � l tl DEPTH 9 LENGTH 0 GRAVEL DEPTH WIDTH 3�2 The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE _ 456� GALLONS # # Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. # # # TWO(2) INSPECTIONS ARE REQUIRED # # Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 31, 1 9 3 3 I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the residence is remodeled to include more t 3�be/dro Signed:, � /� <- Issued by Date: SWP/0/24(1/81) �t o T .C'/�FJua�1 — �G✓ � � S� w�2�o� l�li..�.f� � Did/-�'i✓L d� /00 r �a oCuf° o��. ' ul/ u�ll. Co-�S� f MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG — PERCOLATION TEST SOILS LOG ❑ PERCOLATION TEST PERFORMED FOR: A \/;-/ADATE PERFORMED: LEGAL DESCRIPTION: L () `I I b l5 LDC' tC S P—A i L l F SILLS DEPTH SLOPE SITE PLAN (FEET). <Lt ea vi 2 - 3 �-:= 4 —` 5 0 6- 7 7 p 8 9 10- 11 ; 1= 12 _ 13- 14 15 16 17 18 19 20 l C> q T a Q UN N I GQA`( LAYEQS rrk( sAMPLC 'lAK--GIS 100) WAS GROUND WATER S ( SM ^ LL, '�5— ) ENCOUNTERED? L O LAYC-9, P C ItA0 C-e7\L_ IF YES, AT WHAT E H DEPTH? A IL o,q� g ,9��® , e °ooaa®eee�a ®e ® er pO 000 a °000°°o ° eeo °ao° eoo �iC1101ite1C o Reading Date Gross Time Net Time Depth to Water Net Drop PERCOLATION RATE (minutes/inch) uII C> TEST RUN BETWEEN FT AND FT COMMENTS l_(V4I I GO >?AGI-. f—GPQ- C)P&QAOL � Ile PERFORMED BY: Z./7 4�1 L CERTIFIED BY:4 DA 72-008 (6/79) ENGINEERING INNOVATION IN THE FAR IV �liTFl ENGINEERING STUDIES 6 DESIGN 6 CONSTRUCTION MANAGEMFNT c SURVEYING May 24, 1983 Mary Lou Cacy Marston Real Estate 2804 W. No. Lights Anchorage, Ak. 99504 Dear Mary Lou, Enclosed please find the soils log and a partially completed MOA permit application for Andrew Schwarz. These need to be taken to MOA-DHEP at 825 "L" Street, 4th. floor, with $20.00, and they will issue a permit for an upgrade. Then an "approved" excavator can take the permit and perform the upgrade. I think he will also arrange for inspections. If you have any questions, please call. Again, I'm sorry this has taken so long. Sincerely, c4l� Ted HjEnineer Staff TH/kn encl. RCTIc ENGINEERS, 506 W. 36TH AVENUE @ ANCHORAGE, ALASKA 99503 ® 907/277-8593 1"t !�&di it INC.9� 3901 PATRICIA LANE * ANCHORAGE. ALASKA 99504 0 907/333-9428 (AcCOUNTING) FVq UHC0 PD L Q T Y OF A HCH0GRQG Development Services Departments Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 011-221-17 Legal description SEACLIFF BILK 1 LT 16 Expiration Date: 0 6 Z`i Site address 5308 SHORECREST DR Anchorage AK 99502 Current property owner(s) Jeanne Roth The On -site system(s) is/are approved for bedrooms X Conditional approval for 4 bedrooms, with the following stipulations: Comments or advisories: new septic tank to be placed per permit OSP231361 summer 2024. Money held in escrow. go Original Certificate Date: 2/21 /2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA ApprovaLjune 2022 MUNICIPALITY OF ANCHORAGE o Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 011-221-17 Complete legal description SEACLIFF BLOCK 1, LOT 16 Location (site address) 5308 SHORECREST DRIVE, ANCHORAGE, AK 99502 Current property owner(s) JEANNE M ROTH 1994 TRUST Day phone 2. ON -SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: ❑ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ® Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel ❑ Plastic ® Concrete ❑ Fiberglass — APPEARS To BE Age 47 - See advisory if steel older than 20 years — CIRCA PER MOA DOGS 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ® Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: F1 C—Q) 7-0 L"'T e-- l/-T;— Distance: U Expedited review requested: ❑ By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee $ Waiver Fee $ 2 2 Date of Payment t 0 / << 1 IZV I- COSA # 0 S C Z 3 (3 c) 3 G,0'^8 i '1 r0 ,v /. L✓ C o S,,i Date of Payment Waiver # OS V 2 �� L 0 COSA Application.doc COSA Checklist.docx COSA Checklist Legal Description: SEACLIFF BLOCK 1, LOT 16 Parcel ID: 011-221-17 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA - PUBLIC &/OR CLASS “A” WATER Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume NA gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank NA Date of pumping NEW TANK PENDING SPRING 2024 Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 1983 TRENCH ALL standpipes present per record drawing Total measured depth from grade 11.6 ft (max) Measured depth to pipe invert from grade 5.4 ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes (MT) go to bottom of effective (ED). If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced 2000 gallons 10/09/23 date Any rejuvenation treatment (past 12 months) N If yes, enter date Adequacy test date 10/10/2023 Results Pass Fluid depth prior to test 0 in Water added 750 gal (Sump extends 75” below invert) New fluid depth 55 in (20” BELOW SUMP INVERT) Elapsed time 60 min Final fluid depth 0 in Absorption rate 600+ gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) 48 in (MOA 4’ ED) Effective depth used 0 in (FINAL FLUID DEPTH) Effective depth remaining 48+ in Comments/Deficiencies: Approximate total measured depths from existing grade at sump. ED per visual observations & available record documents. Sump pipe extends approximately 6.2’ or 75” below sump invert as noted above at 75”. No backflow to crib noted with presoak or testing. COSA Checklist.docx E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) - NA Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No *8+ ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS *Per survey & MOA docs, the end of the 1983 trench is approximately 8’ from the property line. Owner is obtaining ROW with LNOs from the affected utilities along with escrow letter for this Conditional COSA. Attached are the 3 install bids. G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Engineer’s Printed Name CURTIS HUFFMAN, PE Date 02/08/2024 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & 02/08/24 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / FirstWaterAK@gmail.com February 8, 2024 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: CONDITIONAL COSA - CCOSA LEGAL: SEACLIFF BLOCK 1, LOT 16 Due to seasonal winter conditions and other factors, we are requesting a Conditional COSA for the above referenced property. The pending permitted OSP231361 4-bedroom septic tank upgrade has been impeded due to these conditions and other factors with no specific known date on when the septic tank will be installed. The septic tank will be installed in the spring of 2024 once the conditions are favorable for installation. The system has been working for the occupants and granting of this Conditional COSA (CCOSA) will not impact any of the neighboring properties or pose a public health risk. Attached are three septic upgrade estimates and escrow letter from title for the pending installation. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / FirstWaterAK@gmail.com February 20, 2024 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: SEACLIFF BLOCK 1, LOT 16 – FIELD TO LOT LINE WAIVER Per the recent, previously submitted as-built survey by Buku Saliz, LS dated October 2, 2023, the existing end of the septic field is within the required 10’ separation distance to the lot line. Per this as-built survey and the record documents in the MOA file, we are requesting a waiver to 8’ to the lot line currently. The portion of this encroaching septic system has been in operation since 1983 with no known issues, meets other separation requirements and we do not expect there to be any adverse effect on the adjacent lots by granting the waiver. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. Municipality of Anchorage� U_ ,� s P.O. Box 196650 0 4700 Elmore Road Anchorage, Alaska 99519-6650 0 (907) 343-7904 0 Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Division On -Site Water and Wastewater Program * * * * VARIANCE/WAIVER REVIEW * * * * Waiver#: OSV241004 P I D#: 011-221-17 COSA#:OSC231390 Permit#: Legal Description: SEACLIFF BILK 1 LT 16 Engineer: First Water Consulting Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 8.0 feet. This waiver approval applies to the existing absorption field only. Any future upgrade to the on - site wastewater disposal system will require all separation distances be met or another approval from this department. ................................................ 0 0 0 0 M M .................. 0 a M M M M 1 Waiver is Granted: X Waiver is not Granted: Date: Z!/20 Z I Approved by: I /Name of viewer **** VARIANCE/WAIVER REVIEW **** Authentisign ID: 5A549B51-DAC9.EE1 1-85F9-60458DD68161 ESCROW HOLDBACK AGREEMENT To: Municipality of Anchorage Agreement between: Karen King, Charles Miller, Jeanne Roth and Stewart Title Property Address: 5308 Shorecrest Drive, Anchorage, AK 99502 File No. 2231381 Amount withheld: $30,000.00 The undersigned parties authorize Stewart Title to escrow funds in the amount of $30,000.00 from the seller For the purpose of: COSA It is the sole responsibility of the undersigned parties to provide invoices to Stewart Title for payment. Upon receipt and with Municipality approval, Stewart Title shall pay invoices for the above -mentioned work. In the event parties are requesting to be reimbursed for invoices they paid out of pocket, Stewart Title will require evidence of paid invoices before any reimbursement is paid. Once work is complete and invoices paid; any excess funds will be refunded to the seller. The undersigned parties hereby jointly and severally indemnify and hold Stewart Title harmless from and against all costs, damages, judgments, attorneys' fees, expenses or obligations of every kind and descriptions which, in good faith, it may incur or suffer in connection with this escrow holdback. Dated: 02/12/24 Buyers: Karen King rI��entivas 1whe M &A 1994 trust eanne Roth Stewart Title of Alaska ft,�DocuSigned by: IA,S�LI. �-GIIn,S Charles Miller — — —SHORECREST DRIVE— — O Co m M EO AVQ 0.0O1 -EO-EO X , Eo REBARr. _ Eo �ER350.00 — -EO EO UTILITY 10' UTILITY EASEMENT peo eH \o UTILITY LINE POLE SEPTIC STANDPIPE I I I Co I Co I I N LOT15 W O 0 0 00 ASPHALT DRIVEWAY II GO�GRESE::. 6do 6 0 0. 2-STORY N FRAME HOUSE 0 LOT 16 30,017 sq. ft. N 620 3, 3q„ UNSUBDIVIDED EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED SUBDIVISION PLAT (P-659) ARE NOT SHOWN HEREON. THIS DOCUMENT DOES NOT CONSTITUTE BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THATA SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. UNDER NO CIRCUMSTANCES SHOULD ANY OF THE DATA HEREON BE USED FOR CONSTRUCTION OF FENCES, IMPROVEMENTS, OR FOR ESTABLISHING PROPERTY BOUNDARIES. THIS SURVEY REPRESENTS A MORTGAGE LOCATION SURVEY PREPARED IN ACCORDANCE WITH THE ASPLS MORTGAGE LOCATION SURVEY STANDARDS. 7Z SHED THIS MORTGAGE LOCATION SURVEY SHOULD ONLY BE USED FOR A SINGLE PROPERTY TRANSACTION. RE -USE OF THIS DRAWING BY THE ORIGINAL CLIENT OR BY OTHERS, FOR ADDITIONAL USES ATA LATER DATE WITHOUT EXPRESS CONSENT OF THE SURVEYOR IS A VIOLATION OF FEDERAL COPYRIGHT LAW. UNLESS GROSS NEGLIGENCE IS DISCOVERED, THE LIABILITY EXTENT OF THE PREPARER SHALL BE LIMITED TO THE AMOUNT OF FEES COLLECTED FOR SERVICES IN PREPARATION OF THIS PRODUCT. 0 15, 30' LOT 17 OF *: 4 9 TH ................ ......... .... �'• B u Saliz : o LS-14837 rl f O FES\\O� \_ AS -BUILT I HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY: LOT 16, BLOCK 1, SEACLIFF SUBDIVISION ANCHORAGE RECORDING DISTRICT, ALASKAAND THAT THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS EXIST EXCEPTAS INDICATED. DATED THIS 2nd DAY OF OCTOBER, 2023, AT ANCHORAGE,ALASKA. FIXED HEIGHT, LLC C.O.A.122554 Land Surveying Services 907.290.8949 225 VV 23rd Ave., Anchorage, AK 99503 WWW.FIXEDHEIGHTCOM JOB # 23154 I NO CORNERS SET THIS DATE I SCALE 1" = 30' MUNICIPALITY OF ANCHORAGE ' DEPARTMENT OF HEALTH 8. HUMAN SERVICES Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING ,<KEIVtb JUN 23 1999 UNICIPAM OF ANCHORAGE ENVIRONMENTAL SERVICES DIVISION Parcel I.D. # 011 -221 -17-000 HAA # 1. GENERAL INFORMATION Complete legal description T.nj- 1 6 • Black 1.- Reacl i ff Subdivision Location (site address or directions) 5308 shorecrest Drive Anchora e AK Property owner _Jim Antisdgli Day phone ( 360) 260-1094 Mailing address 13805 N.E. 45th Ave. Brush Prairie WA 98606 Lending agency Day phone Mailing address Agent Day phone Address Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual well Community well Public water 4 NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site xx Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025(R".1/91) Front MOAX21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I furtherverify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater dispo c on s a ste��P ompliance with all Municipal and State codes, on � ordinances, and regulations in e ethe ate of this inspection. V"Ittater Consultay ,s, l C. 2 -7 —6 / 7 .. r Name of Firm &ftnA�,o_L.,„ In„rc is Phone Address Engineer's signature Alaska Water & KWtewater Consultants, Inc. Shaft be PAID $ 2 G 5 csz 4 or prior to, closing for the Engineering Smices Provided. 6. DHHS SIGNATURE Approved for Disapproved. By: U bedrooms. Conditional approval for Additional Comments 9l1TIC Date /_/ 23 bedrooms, with the following stipulations: Date 6 - The- The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in orderto satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025(Rev.1/91) Back MOA021 JUN 26 1999 Municipality of Anchorage MUNICIPALITY OF ANC DEPARTMENT OF HEALTH & HUMAN SERVICli�IRONMENTALIIRVICE 'I Environmental Services Division 825 L Street, Room 502 • Anchorage, Alaska 99501 • (907) 343-4744 Health Authority Approval Checklist Legal Description: S��YC,' Cil d Ll L 1 g / Parcel I.D.: oil 22 / 17-000 A. WELL DATA Well type A If A, B, or C, attach ADEC letter. ADEC water system number present(Y/N) Total depth Sanitary seal (Y/N) Date of test Static water level Well production MOM Date completed Cased to g.p.m. Casing height (above r Wires proper] otected (Y/N) T INSPECTION WATER SAMPLE R LTS: \ Coliform Nitrate Other bacteria ate of sample: Collected by: B. SEPTIC/HOLDING TANK DATA C_> �! ;2-J 04-P' g.p.m. Dateinstalled UNV--�JV-Jn1 Tanksizet���t/J Number of Compartments ��4Cleanouts(Y/N)� Foundation cleanout (Y/N) "ffi&pre�s n (Y/N) 6 High water alarm (Y/N) Date of Pumping Ott, L9 C) Pumper C. ABSORPTION FIELD DATA �2i vN hoc unnE��� _ Qi a-�b R c X213 Date installed I �1 3 Soil rating (g P eft2 or ft2/bdrm) I ®� System type d®� Length ZO Width 3 Gravel thickness below pipe Total depth i Effective absorption area Iib c21 ¢Monitoring Tube present C(�Y/N)� Depression over field (Y/N) �� Date of adequacy test /� Results (Pass/Fail) `5 For q 4- bedrooms Fluid depth in absorption field before test (in.); be-� Immediately after °33gal. water added (in.): 40 � Fluid depths (ins) Minutes later: i 3 )-D Absorption rate = —g-p.d. A10r./E. I Peroxide treatment (past 12 months) (Y/N) beAxnc )A✓ If yes, give date zf /d& 72-026 (Rev. 3/96)' 'j'(F 61JLy D. L TATION Date installed Manhole/Access (Y/N) High water alarm level at* C as tested E. SEPARATION DISTANCES `Datum TION DISTANCES FROM WELL ON LOT TO: Septic/holding taa- fre Absorption field on lot Public sewer main Sewer /septic—sem Size in gallons On adjacent lots _ On�adjacent Lots Public se�ve�r�BC�hole Lift station off' level at* SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: f Foundation 5 (-F" Property line S- /�- Absorption field F Water main/service line ID /4 Surface water/drainage /CSO / f Wells on adjacent lots 200 (h SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO: Property line j D Building foundation t'O d-- Water main/service line ) Surface water /00 /� Driveway, parking/vehicle storage area 'S I"f Curtain drain pu,jvc VJU F. ENGINEER'S CERTIFICATION I certify that I h. e t ine t i in conformanc wit Signature Engineer's Name Date b �Z Wells on adjacent lots `D-CY) 4 - inspections and review of Municipal 3s in effect on this date. HAA Fee $ 30 f7 O -D Date of Payment Receipt Number 72-026 (Rev. 3/96)' Waiver Fee $ Date of Payment Receipt Number Alaska Water & Wastewater Consultants, Inc. 6901 Debarr Road, Suite 2-B — Anchorage — Alaska 99504 Phone (907) 337-6179 — Fax (907) 338-3246 Consulting Engineers June 23, 1999 Municipality of Anchorage Department of Health & Human Services Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Subject: Septic System Inspection at Lot 16, Bk 1, Seacliff S/D. To whom it may concern: Per the request of the property owner, we performed and adequacy test on the septic system which serves the subject property. Comments associated with our HAA application are summarized as follows: • The septic system consists of an undocumented crib and septic tank as well as a documented trench. • The dimensions and absorption area of the crib are unknown. • According to the 1991 HAA application, the septic tank is 1500 gallons. • The crib clean-out is adjacent to the north lot line and it is unknown whether the perimeter of the crib extends into the utility easement. See the attached as -built survey. • According to the property owner (Jim Antisdel) the water key box is located near the northeast property corner (at Shorecrest Drive). • As was stated in the 1991 HAA, there is no foundation clean-out. If you have any questions please contact us at 337-6179. Sincerely, P.E., M.S. T I SCALE 1°`30' DIO Vic stir KRAME _oi vn 1 y .0 14 ti; •• �`. ti v w ^� tea/ ; �/ T•A v4r,•'1 JV H r1 A5 Sutlr PIX -ORD, OWIR THAN ibi':',. ' I•-i.�+�l (;'J 7P4s: kfC;:;'i"LrCt) Ft.41, f�Y•::; (*lU! :siil'�VV'i+i HcRt�[u. No Cnrnor! FAr This pat I herPDV Certify tet I M" sur ftod Ina 1011DWing Oawloed PrOOGM, LOtYL.wioek I %Ef C IrP OUBi7. AnefwrM r0oiardi+r0 heeinct, AWeks, end !Mr the ,Mpreveneel++! elt,uspd tenon us within +les poperty Ana end do not etisrl41p or eeer0eah " the popsy lying >dµ�r Ow.rn, et,wk ne 4.W* a,wnri Ort, 'pf*pWfV Iyinp wlea41h9 thWato sneroseh on 11141 pre(W= In queetl0n erld tho ShWS sone roed1V41y1, irlinRnlniOn limo or other risible perernanb on rid pntptrty iNeep+ as irAhm ed hsreort,. Anohorep, Awsks _ — 92 Atl4 • e% ✓•1 ,eFc-Al J p�. Book Na. Pees No. Fier I,J N� MUNICIPALITY OF ANCHORAGE�� • '� DEPARTMENT OF HEALTH & HUMAN SERVICES p Division of Environmental Services On -Site Services Sectionh' P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # a.al- M d-eyU HAA # Q 1q 1 n 1. GENERAL INFORMATION Complete legal description Loi 112, JaK 1 S EACu F F g/p Location (site address or directions) 5'S08 !9 [.m,z e v.a_t by - Property owner �• J ? T A U'e U -P Day phone Mailing address /moo g1 ' SL,e*-�u��-Q D� Lending agency—�1rsll r'igr2A_t- /-)a'•flPayphone A�7- 077f b Mailing address Agent Day phone Address Unless otherwise requested;; F1AA will be held for pickup. 2. NUMBER OF BEDROOMS:' i 3. TYPE OF W4,TER SUPPLY: Individual well Community well "Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site — Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA #21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that m. investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm e �rJ� !< 1>a i= Phone X79-3 4l6 I Ebb n Address ao 7 Date Engineer's signature �•rI •eeao cau �. �,.'� � n .a+nan+. .1 a y9 o$bcn S•t,ulclar.d !64 6. DHHS SIGNATURE 4 Approved for 4� bedrooms. Disapproved. bedrooms, with the following stipulations: Conditional approval for Additional Comments — By. Date lO Z/l(� The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 1/91) Back MOA 421 Legal Description: A. WELL DATA Municipality of Anchorage Department.of Health & Human Services _ HEALTH AUTHORITY APPROVAL CHECKLIST Parcel I.D. Well type "A If A, B, or C, attach ADEC letter. ADEC water system number Fysl L) CJDy8x Log present (Y/N) Total depth Sanitary seal (Y/N) Date of test Static water level Well flow Pump level Date completed Cased to FROM WELL LOG SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot Absorption field on lot Public sewer main Driller Casing height Wires properly protected (Y/N) AT INSPECTIONALINICIPALITY OF ANCHORAGE ENVIRONMENTAL SERVICES DIVISION ; On adjacent lots ; On adjacent lots Public sewer manhole/cleanout Sewer service line Petroleum tank WATER SAMPLE RESULTS: Coliform Date of sample: B. SEPTIC/HOLDING TANK DATA Nitrate Collected by: Other bacteria OCT 15 1991 Date installed l4-76 2 Tank size Compartments Cleanouts (Y/N) Foundation cleanout (Y/N) Depression (Y/N) High water alarm (Y/N) 7 Alarm tested (Y/N) NIA Date of pumping 7/3! 11 Pumper R,210 tom J e -I+,-- SEPARATION DISTANCES FROM SEPTIC/HOLDING TAN//K TO: Well(s) on lot IYA On adjacent lots PYA - Foundation To property line �4 Absorption field 60-tWater main/service line ! t> f Surface water/drainage 72-026 (Rev. 7/91) Front CONTINUED ON BACK PAGE C. LIFT STATION Date installed Size in gallons Vent(Y/N) High water alarm level "Pump on" level at Meets MOA electrical codes (Y/N) Manufacturer Manhole/Access (Y/N) SEPARATION DISTANCE FROM LIFT STATION TO: Well on lot D. ABSORPTION FIELD DATA On adjacent lots "Pump off' level at Cycles tested Surface water _ Date installed M 3 Soil rating l System type Crt) b a, T&t. eic, Length o10 Width 3 Gravel thickness -Total depth 10 Total absorption area 1/90 f Cry y Cleanouts present (Y/N) J / Depression over field (Y/N) N Date of adequacy test Results (pass/fail) 7F—C" for 7-4ce 1:0 U bedrooms Peroxide treatment (past 12 months) (Y/N) t�l If yes, give date SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot N//� On adjacent lots ) /& Property line l� To building foundation so, To existing or abandoned system on lot N�A On adjacent lots o � Cutbank A Water main/service line Surface water N1�4 Driveway,J parking/vehicle storage area 3 Curtain drain t-/, E. ENGINEER'S CERTIFICATION 1 certify that 1 have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date,;of,,this inspection. Signature 2 2 C Engineer's Name 7n LU -e- c-+ QU uy V �r ,r Date HAA Fee $ / '�J 0 U Waiver Fee: $ Date of Payment U _�'/ / G�7 Date of Payment Receipt Number a��>� y / ' Receipt Number 72-026 (Rev. 3/91) Back MOA 21 a �~~ 4,En; V»LJ Fcl<. L.- n.- H=1 .. E -H,= " 20JWEST l5YH.AW[NUESUlTE206 ANCHORABE^ ALASKA 99502-3904 (Y07)279^3916 SEPTIC SYSTEM ADEQUACY TEST LEGAL: Lot 16 Block 1 Seacliff l-BCATI0N: 5308 Shorecrest Drive OWNER: Jeff and Judith Loevenfel RESIDENCE: Single Family, �, Bedrooms ' SEPTIC SYSTEM: FROM MUNICIPAL RECORDS- TANK- 1500 Gal , ABSORPTION SYSTEM: Crib and Trench ABSORPTION AREA: Unknown SOIL RATING: 100 INSTALLATION DATE: Trench 6/1/83 DATE OF LAST PUMPING: 7/3/91 Roto Rooter DATE OF TEST: September 4 1991 TEST : System was inspected and measured. Tank was found with 4 feet of cover and with a liquid level of 50 inches. Crib was 8.3 feet deep and with a liquid depth of 63 inches. Trench monitor tube was 9.3 feet deep and with 16 inches of water. 450 gallons of clean water was added to the trench while the water levels in the tamk, the crib, and the trench monitor tube were monitored, The water levels in the tank and crib did not change, while the level in the trench monitor rose 5 inches. The absorption rate was monitored for 60 minutes" During this time the water level had dropped 4 inches, indicating that 360 gallons of water had been absorbed, TEST RESULT: This system meets the code requirements of the Health and Social Services Department of the Municipality of Anchorage. NOTE The operational life of all septic systems depends on the local soil conditions, groundwater levels-�i that may fluctuate during the year, and the water usage of the family being served by the system" These conditions are outside the control of the eva1uator of this septic system" We can therefore not give any estimate of how long this system will function satisfactory for current or future occupants^ Pi "v Owner }/ j i?J)y" ; l�� J�'ji' 'off r la _,. Time Phonej�'1 e��)- MaiingAddress `�- � � ./.1�(_i1 � -�,��J� _.i �� Zip Code_. Buy er,,-�1 Address „r'/_ �/� / 1- Zip Code Lending Institution /Jj�-/�j_:� //- -�!'� J .,.._;�)�(� Phone OIL --)L' 4 rw-Q Date i Address� /:- - - ��. -? r /�_.-3y�� Zip Code Realty Co. & Agent �- 'f.�f/-!'<.1 Address C_a'J/!� — ,/� �%J G"�" .//1 Zip Code Legal Description Street Locat(on _. Type of Residence Inspector 0--816g-le Family ❑ Multiple Family No. of Bedrooms ❑ Other Water Sup y wi mmunity - �i%�.y�-'.�.p.>�. ATTACH WELL LOG. A well log is required for all wells drilled For wells drilled prior to that date, give well depth (attach to P g since June 1975. if available ). . � ❑ Public Utilil MUNICIPALITY OF ANCHORAGE Sewer Disposal idual Year Individual Installed: DEPT. OF H-F.LTH A Public Utility When Connected to Public Utility: ❑ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. APIR 14 SE Time Time Time Time OIL --)L' 4 rw-Q Date Date Date Date Inspector Inspector Inspector Inspecto ``��' �rQ Tt Field Notes: — U , MUNICIPALITY OF ANCHORAGE DEPT. OF H-F.LTH A ENVIRONMENTAL PROi'ECTION APIR 14 SE RECEIVE® (!,l-) APPROVED BEDROOMS 'CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CONDITIONAL APPROVAL` DATE BY: Soils Rating Date Sewer Installed Well To Absorption Area Well Log Received Septic Tank Size Well to Tank 72023 (3182) April 20, 1.933 An,,irew ;chwarZ 5 3 01 3 Shorecrest Dr. Anchorar,o, AV 9950,11 Wi u ti)"C.Cte j.ot 1.6 "llack I Seacliff Subdivision Approval for the illclivi(byll_ se1m1:.' arls! viaLer Eacili't-Ac)s cannot h I n - p�letefl *. e granted until tho fojjo,,,iljg jterjjr� Ilave boo com' submitted, to tilir� z3(�,ptic tank pu-mpod 171 11 a rcceil, r2 Ced 0 'be departviont- total- of d n -- s t on the rocnipt and voriEied by a rc'CjiStCj:edl enginec z 1 , -1,3 t -� i r S - or EY t,lic actuaL numlt)er Of 9W,11ons �pixz-Iipcd. T1 tO v J, t!'l 2i -,e oi., the E;eptic tank. z\ four (4) ilich cleanout needs to be illstalle{� to the :3e,0 - tic (A) inch C"i0all-ou"': need -s to be i-f-Istalled to the leaching area. to ljc, pnrf-.ojf!IjC0j {)n t! existing An adoclua(7Y test "'Qe-df loac,hinq area. 'j'!IiS t0-s'L will deterj.t.lilve if thn systo"n 15 .(uato i,,.,ccording to ty1t)_onal standzrls. A li3tinq of private firms performing the This report neods to bo sulhr-Littod to this office fol) our re-viev. noti-Ey this S}?' )a for a reinspection when the noted discrepatncio, have lbeen corrOCtf3d- Ti there are ally further. �f --� e� - 4 72{)• r. q Call ttAj3 of jco at 2 ,ue"tion's, pinz).� 1;incp I lr�ilyr Twhert C. Pratt !',s3ociate _2nvironmental Spucialist RP23/1)/El Oncl E -.,a r e ENGINEERING INNOVATION IN THE FAR N OPTH April 25, 1983 ENGINEERING STUDIES a DESIGN 0 CONSTRUCTION MANAGEMENT c- G'UrR,VC-ING Andrew Schwarz c/o Mary Lou Cacy Marston Real Estate 2804 W. Northern Lights Anchorage, Alaska SEPTIC SYSTEM ADEQUACY TEST LEGAL: Lot 16, Block 1, Seacliff Subdivision HOUSE: Two story duplex, 4 bedrooms, 4 bathrooms. SEPTIC SYSTEM: From on-site determination no MOA records Tank: 1,500 gallons Absorption System: Absorption Area: Soil Type: DATE OF TEST: April 23, 1983 Seepage Pit-Prob. Log Crib = 3.9 ft. Normal water depth Unknown Unknown TEST Water was added to the leach field through a 4" stand pipe in PROCEDURE: 100 gallon increments, with a 2 -minute lapse between successive inputs. The sump became full when 500 gallons had been added. Total rise in liquid level in the sump was 24.5", which corresponds to a rate of rise of 245 gallons per foot. Absorption monitoring was then carried out for a period of 90 minutes. The resultant plot of absorption vs. time, with the extrapolated absorption capacity, is attached. RCTI& NGINEERS, INC. 1506 W. 36TH AVENUE o ANCHORAGE, ALASKA 99503 ® 907/277-8593 3901 PATRICIA LANE o ANCHORAGE. ALASKA 99504 0 907/333-9428 (ACCOUNTING) Andrew Schwarz Adequacy Test April 25, 1983 -2- RESULTS: The plot of absorption vs. time yielded a theoretical absorption capacity of 390 gallons per day. The required absorption capacity for a. 4 bedroom house is 600 gpd. The system fails to meet Municipality of Anchorage requirements. COMMENTS: Upgrading of the soil absorption system will be necessary to comply with MOA requirements. The septic tank capacity is adequate. Caps should be installed on the stand pipes at the tank and at the soil absorption system. When the tank was pumped, there was approximately 14" of sludge. Pumping should be done every two years to avoid sludge accumulation. 41 Q 'e Oa�eg ® G 9V� �OOee0a0n00e00 aaa a0000G.0 a ono eo to $ Sid ey rk ®® � Do CE -1 68 O'0%0ooaoa°ne� �® '°ROFESSIO . ice, " Mi6nicipality ®f Anch&iage MEMORANDUM P DATE: June 2 9, 1981 pp ANCHORAGE MUNICIPALITYF 1 [ T-1 F.. TO: Customer Service Supervisor, AWSU eFaT.p p.E.TI-'� P � ENVIR;�It! .]r;;A. ,.. FROM: General Manager, AWSU C,-� v SUBJECT: Sewer Mandatory Hookup Rr CEJv E® Municipal Code 15.65.030, prohibiting the use or installation of a septic tank—seepage system disposal facility where sanitary sewers are available, was enforced by the Department of Health and Environmental Protection prior to 1978. Responsibility for monitoring and enforcement of the Code, which became known as the "sewer mandatory hookup code" was assumed by the Anchorage Water & Sewer Utilities beginning with 1978. The Utilities put forth every effort to compel customers to connect to the sanitary sewer system where service was available. Success has been negligible. Through several confrontations and the rate case situations, our Legal Office has generally taken the stand that the intent of the Municipal Code, as written, was to prohibit the usage of septic tank systems. An attempt to revise the Code to a cleaner, mandatory hookup situation failed this last spring. Our position technically, therefore, is that no mandatory hookup requirement exist in the Municipality. It is important not to mislead customers into relying on a "mandatory hookup program". This is especially true in the case of developers, who may be trying to economically justify a marginal project based on the forced connection by the Municipality of other properties benefited by the developer's project. In conclusion, everyone should be cautious about building up our customers' expectations concerning forced connection to the Municipal sewer system. It is also important to restructure our th4aking around the fact that specifically there is no such thing as mandatory hookup in the Municipal Code. ( J HN L. HARSR1A General Manager Ancliorage Water & Sewer Utilities cc: Division Managers Bert Hall Permit Office PW — Assessments & Agreements �. Y S, r py �AONMENTAL (CM OFFICE f:0 S K i,11TE 22 360' ALA KA PIC SAM wober 10, 1901 818 the the Seacm sul ;file 1�this office rove off 1165 the io Is InCOT jjg listed n 10) - and With the Ino o"A ---------- ----------------------------------------------------- -- - - - - - - -- - - - - - - - 2465095;# 2 - - SENT By;Xorox TolOCopjor 7021 ;10-15-91 ;10�31AM