On -Site Wastewater Disposal System Permit
Permit Number: OSP231344
Work Type: Septic Renewal
Tax Code Number: 01122123000
Site Legal Address: SEACLIFF BLK 1 LT 22A G:2424
Site Mailing Address: 5112 Shorecrest DR, Anchorage
Owner: MANN MATTHEW &
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Effective Date
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
Ment
X0 sr•
Department
10/19/2023
10/18/2024
19287
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
4
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
iSpecial Provisions:
1. Septic system installation must meet the requirement of the ADEC for the well waiver.
2. The private sewer line shall maintain 100 ft separation to the public water system, as shown on the
engineer's site plan.
3. Prior to Inspection Report approval, a full approval for the well separation from the ADEC is required to be
submitted to Onsite.
4. The Onsite inspector must be at the bottom of hole excavation for the trench to confirm insitu soils are
sand.
Reeeive&By: LJ!5up r1 +0 Date:
Issued By: Gv Date:
0// G ZZZ
T1 _
4j i
Community Development Department - Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 011-221-23
Property owner(s) Matthew Mann & Erika Wessel Day phone (907) 301-5359
Mailing address 2611 W 100th Ave, Anchorage, AK 99515
Site address NHN Shorecrest Drive
Legal description (Sub'd., Block & Lot) Seacliff, Block 1 Lot 22A
Legal description (Township, Range & Section)
Lot Size 19,287 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR: APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field ❑X Initial ❑
Single Family (SF)
❑X
(w/wo ADU)
Septic Tank INUpgrade ❑
Duplex (D)
El
Holding Tank ❑ Renewal FX -1
Multiple Dwellings
❑
Privy ❑
(SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that
this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:. '2- 3Z Waiver Fees: $7 Z5 13S
Date of Payment:%01,612 Date of Payment:
Receipt Number: 0/ 14 6.61) Receipt Number:
Permit No. DSP 2 -3 J3 Y L— Waiver No. (20,\jam23 1 D�-S
Permit App_':- : ,_.,:c:
Municipality of Anchorage 4'"~s
— I)r.pon•tinent
P.O. Box 196650 0 4700 Elmore Road
Anchorage, Alaska 99519-6650 0 (907) 343-7904 0 Fax (907) 343-7997
http://www.muni.org/Onsite
Development Services Division
On -Site Water and Wastewater Program
* * * * VARIANCE/WAIVER REVIEW * * * *
Waiver#: OSV231055 COSA#: Permit#:OSP231344
PID#: 011-221-23
Legal Description: SEACLIFF BILK 1 LT 22A
Engineer: Forge enqineerinq
Your request for a waiver of the required 5 feet horizontal separation from the absorption field to
the property line has been approved. The approved separation distance is 1.0 foot.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-
site wastewater disposal system will require all separation distances be met or another approval
from this department.
............................................... ■ ............................. ■ 1
Waiver is Granted: X Waiver is not Granted:
Date: /o/C( Approved by:
Name of Reviewer
.............................. ■ ............................. ■ ............... .
**** VARIANCE/WAIVER REVIEW ****
Page 1 of 3
April 19, 2022
Department of Environmental
Conservation
DIVISION OF ENVIRONMENTAL HEALTH
Drinking Water Program
555 Cordova Street
Anchorage, Alaska 99501
Main: 907.269.7623
Fax: 907.269.7650
dec.alaska.gov
Matthew Mann File: Sand Lake Services
Owner of Lot 22A, Block 1, Seacliff S/D DEC Project ID: 16714
2611 W 100th Ave PWSID: 210485
Anchorage, AK 99515 Class: Community
beachbuminak@gmail.com Source: Groundwater
Re: Seacliff Subdivision, Block 1, Lot 22A
Drinking Water Separation Distance Waiver - Updated
Dear Matt Mann, Owner of Lot 22, Block 1, Seacliff Subdivision:
On April 18, 2022, this office received an engineering submittal from Forge Engineering requesting
an updated waiver from the 200-foot required separation distance between a public water system
drinking water well to a proposed onsite wastewater disposal system on Lot 22A, Block 1, Seacliff
Subdivision. This letter issues a Conditional Separation Distance Waiver for the requested
reduction of the State’s minimum separation distance requirement between drinking water
wells and sanitary sewer components, as detailed in the submitted engineering information
and outlined below.
Project Description
This property is located on Shorecrest Drive and backs up to the bluff along Turnagain Arm. Many lots
in this area are served by the Sand Lake Services Public Water System, PWSID 210485, or other
drinking water wells, and they have individual sewer systems, typically onsite septic tanks and drainfields.
Two of Sand Lake PWS’s groundwater wells are nearby (Wells #1 and #3). The majority of Lot 22
is within the 200 foot protection radius around both wells. The only portion outside of 200ft is the
steep bluff dropoff to the coastline.
Well #1 – Drilled May 9, 1964 to a total depth of about 212 feet. Cased to 206 feet.
Well #3 – Completed February 11, 1995. The well log (WELTS #23107) shows it was grouted, and
that it was cased to 525 feet with the intake screen starting at 513 feet.
The submitted sanitary sewer design (dated 4/5/2022) for this property now proposes to install a
Category III Advantex septic tank along with an appropriately designed trench drainfield, no closer
than 120 feet to the Sand Lake PWS wells. Components include:
- Septic tank: 1,500-gallon Advantex FAP (fully assembled package) two-compartment
fiberglass tank with AX20 filter pod
- Drainfield: 7-foot effective depth absorption trench system (11 feet long by 3 feet wide,
designed for 4 gpd/sf)
o Space for a backup disposal field is available >14ft away, towards the bluff
- System is designed for a 4-bedroom or less single family residence, with 600 gal/day
maximum daily flow
Seacliff S/D, Block 1, Lot 22A 4/19/2022
220419 Seacliff SD_Block1_Lot22A Updated Waiver Sand_Lake_210485 WA.docx Page 2 of 3
- All gravity piping from the residence (aka private sewer line) is expected to meet its required
separation distance of 100 feet from both wells.
Separation Distance Waiver
The separation distance encroachment was reviewed based on the following elements to maintain
public safety:
Confined Aquifer: Layers of clay or silt can act as confining layers, which can help prevent
contamination from reaching the water. The aquifers that these wells access appear to be
confined.
Well #1 was drilled through clayey silt from ~72 to 180 feet below ground surface (bgs),
according to the soils log.
Well #3 has layers of clay and/or silt from 335-392, 401-432, and 457-478 feet bgs, and a
static water level of 53ft bgs according to the well log.
Ground slope: The ground generally slopes away from the wells towards the midpoint of Lot 22.
As the property approaches the bluff, there is an increase in elevation. However, groundwater
flow through this area is still generally away from the well and towards the coast.
Nitrates: Trends of increasing nitrates can indicate failure of any nearby septic systems. Nitrate
samples for Sand Lake PWS 210485 are available from 1993 to the present, and indicate very
low levels, typically around 0.2 mg/L.
If operated and maintained correctly, any effluent that passes through this system will be treated
to a higher degree than that of the conventional septic system previously approved March 23,
2021, further decreasing the chances of fecal contamination.
Based on an evaluation of the available information and endorsement of the submitting engineers, a
Separation Distance Waiver to 120 feet for the onsite sanitary sewer components outlined
above is issued in accordance with the State’s Drinking Water regulations, 18 Alaska Administrative
Code (AAC) 80. Please forward any record drawings and documentation of construction to this
office once completed. The separation distance encroachment is approved with the following
conditions:
The wastewater system must be installed by a person that meets the requirements of 18 AAC
72.015.
The sewage system must be maintained in accordance with State of Alaska and Municipality
of Anchorage requirements for as long as the system is in operation. The lot owner or their
Authorized Service Provider should keep all records, such as installation records, septic tank
maintenance, inspections, and pumping, and have them available on request. For additional
information, see the following:
https://dec.alaska.gov/water/wastewater/engineering/maintain-septic
https://www.muni.org/Departments/OCPD/development-services/wells-septic
Any changes, constructed or natural, may void this waiver and the sewer may be required to
be relocated.
Seacliff S/D, Block 1, Lot 22A 4/19/2022
220419 Seacliff SD_Block1_Lot22A Updated Waiver Sand_Lake_210485 WA.docx Page 3 of 3
Limitations
This determination was based on current site conditions and well information available to the
Department. Occurrences of floods, earthquakes, and human activity can change the geophysical,
chemical, and biological conditions under which this determination was made. This determination
does not preclude the Department from reevaluating this separation distance waiver in the event such
conditions change or additional information becomes available to the Department that would warrant
further review.
Approval of this waiver does not obligate the department to approve future waiver requests
proposing the same design, is not an approval of omissions or oversights, and does not guarantee
correctness of the functional design or waive the owner’s responsibility for continued compliance
with state, federal, and local regulations.
Informal Reviews and Adjudicatory Hearings
A person authorized under a provision of 18 AAC 15 may request an informal review of a contested
decision by the Division Director in accordance with 18 AAC 15.185 and/or an adjudicatory hearing
in accordance with 18 AAC 15.195 - 18 AAC 15.340. See DEC’s “Appeal a DEC Decision” web
page https://dec.alaska.gov/commish/review-guidance/ for access to the required forms and
guidance on the appeal process. Please provide a courtesy copy of the adjudicatory hearing request in
an electronic format to the parties required to be served under 18 AAC 15.200. Requests must be
submitted no later than the deadline specified in 18 AAC 15.
If you have any questions, please contact me at 907-269-7516 or darlene.galido@alaska.gov.
Sincerely,
Darlene Galido, P.E.
Engineer I, DEC
Cc: Sand Lake Services PWS 210485 Owner: Homewater LLC, homewaterllc@hotmail.com
Sand Lake Services PWS 210485 Operator: Northern Utility Services, dave@nusalaska.com
Forge Engineering: Benjamin Schiller, P.E., ben@forgecivil.com and
Jacob Millette jake@forgecivil.com
Municipality of Anchorage Onsite Water & Wastewater, rebecca.carroll@anchorageak.gov
October 10, 2023
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
10/10/23
Subject: Seacliff, Block 1 Lot 22A – Shorecrest Drive
Septic permit renewal, revision, and waiver request
Dear On-Site Services Engineer:
The permit on this lot has expired, but the builder has let us know that they plan on installing soon.
We would like to apply for a permit renewal.
In addition to this, we were sent a revised as-built of the building footprint, which prevents the
septic tank from being placed in the location on the original permit. We have revised the layout to
fit in the tank, trench, and alternate site in the space that is left without encroaching on the well
more than the existing waivers allow.
Due to the placement of the home, we are unable to achieve 10’ separation from the building
footprint as well as from the property line. For this reason, we are asking for a waiver to allow the
existing and alternate trenches to be located 1’ from the west property line. This location will not
affect neighboring septic, which is on the other side of the lot, and there is no neighboring well.
While the soil is sandy, construction will done with equipment that will not create a pit or
undermine the neighboring property. There are no other options that will not further encroach on
the well, but granting this waiver will not adversely affect this property or the neighboring
property.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231344, Deb Wockenfuss, 10/19/23
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
1"=50'
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
SEACLIFF, BLOCK 1 LOT 22A
FEET
0 50 100
NOTE:
NO SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS
PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC
SYSTEMS.
Oct 10, 2023
SH
O
R
E
C
R
E
S
T
D
R
I
V
E
4-B
DR
M
H
OM
E
10' UTILITY
EASEMENT
CLASS "A"
COMMUNITY WELLS
35' SETBACK FROM
SLOPE FOR ADVANCED
TREATMENT
11' LONG X 3' WIDE, 7' EFFECTIVE
DEPTH ABSORPTION TRENCH
MAINTAIN 10' MIN SEPARATION FROM
FOUNDATION, 1' MIN FROM PROPERTY
LINE, & 5' FROM SEPTIC TANK
1500-GAL ADVANTEX
TANK w/ AX20 POD
MAINTAIN 5' MIN FROM
PROPERTY LINE & 10'
MIN FROM FOUNDATION
ALTERNATE SITE
>14' AWAY FROM
PRIMARY SITE
PROPOSED
WATER LINE
CO
MT
CO
FCO
TH1
GEG
120' RADII
100' RADII
MT
TOP OF STEEP SLOPES
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231344, Deb Wockenfuss, 10/19/23
SEACLIFF, BLOCK 1 LOT 22A
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592R
EGISTEREDPROFE S S I O N ALENGINEER4" PERFORATED PVC (HOLES DOWN)
DRAINFIELD ROCK
3'
6"
6"
3'-6"
7'
DESIGN FACTORS:SYSTEM REQUIREMENTS:
600 GPD PEAK FLOW
PERK RATE: <1 MIN/IN
(SP/SW PER GEG TEST HOLE)
APPLICATION RATE: 4.0 GPD/SF
(CONSERVATIVE RATE USED)
7' DEEP TRENCH SYSTEM
1500-GAL ADVANTEX TANK
w/ AX20 FILTER POD
BOTTOM OF TRENCH: 11' BELOW GRADE
FLOW LINE ELEVATION: 4' BELOW GRADE
TOP OF TRENCH: 6" ABOVE GRADE
600 GPD / 4.0 GPD/SF / 7 DEEP / 2 SIDES = 10.7 LF TRENCH REQUIRED (11 LF SPECIFIED)
4/5/2022
GEOTEXTILE FABRIC
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221073, Deb Wockenfuss, 04/29/22
Carroll, Rebecca M.
From: Carroll, Rebecca M.
Sent: Monday, April 11, 2022 8:15 AM
To: Ben Schiller (Ben @forgeciviLcom); Office Forge Civil
Subject: FW: Public water system to septic waiver
Ben,
This is in regards to the permit for Seacliff B1 L22A
Becea Carroll
Onsite Water and Wastewater
Municipality of Anchorage
343-7908
From: Galido, Darlene E (DEC) <darlene.galido@alaska.gov>
Sent: Friday, April 8, 2022 4:53 PM
To: Carroll, Rebecca M. <rebecca.carroll@anchorageak.gov>
Subject: RE: Public water system to septic waiver
[EXTERNAL EMAIL]
Hi Becca,
Please ask the new engineer / owner to submit the new design for an updated waiver. No fee will be required. We would
like to see a new Applicant Form (https://dec.alaska.gov/media/19772/00a-waiver-only-applicant-certification docx), and
waiver checklist (or a letter from the engineer covering how the design is protective of public health) -
https://dec.alaska.gov/media/19793/70-waiver-source-2020 docx.
Yes, a record drawing / as -built survey (or whatever certification is normally submitted to MOA?) would be great to verify
the system was installed as designed.
The MOA requirements sound good for installer requirements. It sounds like it meets basically similar requirements if the
installer is supervised by a registered engineer.
Thank you for checking! Happy to chat more if anyone needs,
Darlene
Darlene Galido, PE
Engineer I, Drinking Water- Program
(907) 269-7516
dec. alaska. go v/eh/ dw
From: Carroll, Rebecca M. <rebecca.carroll@anchorageak.gov>
Sent: Friday, April 8, 2022 10:51 AM
To: Galido, Darlene E (DEC) <darlene.galido@alaska.gov>
Subject: Public water system to septic waiver
You don't often get email from rebecca.carrollpanchorageak.gov. Learn why this -is-important
1
CAUTION: This email originated from outside the State of Alaska mail system. Do not click links or open
attachments unless you recognize the sender and know the content is safe.
Hello Darlene,
In 2021, a waiver was granted between a public water system and a proposed septic system on a vacant lot (Seacliff Block 1
Lot 22A). The owners sold the property and the new owners have hired a different engineer to design a septic system. I
have attached the waiver and original septic design, as well as the new proposed design. Does the new owner/engineer
need to resubmit for the waiver? They are designing based on the 120 ft waiver granted in 2021 and are proposing an
advanced wastewater treatment system.
The waiver grants a conditional approval. What are the conditions that have to be satisfied to be given full approval? Do
you just need to see the record drawing/as-built survey after installation to verify that they didn't end up installing it closer?
Also, the letter states that the wastewater system must be installed by a person that meets the requirements of 18 AAC
72.015. All wastewater systems installed under the MOA's jurisdiction are supervised by a registered engineer or their staff
(whether it's one of our certified installers or a homeowner). Is something more stringent needed in this case? Do they
need to be a certified installer with the ADEC? Or if the homeowner desires to install the system, do they need to get
approval from ADEC?
Thank you,
Becca Carroll
Onsite Water and Wastewater
Municipality of Anchorage
343-7908
MUNICIPALITY OF ANCHORAGE
ADVANCED WASTEWATER TREATMENT SYSTEM
MAINTENANCE AND REPAIR AGREEMENT
THIS MAINTENANCE AND Itf_'.PAIR AGREEMENT. herein the " AGREEMLNT" made and
entered into as of this 2Z. Div of _.! ,
of 20�, by anti between
llcrcill the "0\'V\1 R,,, and the MulliciPality of
Anchorage, helvitl the "MUNICIPALITY", in accordance with Anchorage Municipal Code
(A\,IC) 15.65.365. In consideration of the nuttuul covenants contained herein, the parties to this
Agreen'ent agree as follows:
1. r#alvauaectl �1'aastcaa iter "I'reatancrlt S altct'�s. 'I'hc ��tunicipalit<� grants perlllission to the
Ovvnlcr to utilize and operate an Advanced Wastewater Treatment System (A\WWTS)•
described as Advantex Waste Water Treatment System
located at (legal description)
Seacliff, Block 1 Lot 22A
2. Maintcmanite, Re .11rs and riltra o-a#ions.
( \ neer is required to read, understand and Initial each sectlotl)
111 Throughout the tern' of this Agteen'ent, tine Ownershall enter into as service agreement
with an A\\'VVTS sct�xice and maintenance,provider• :approved by the Municipality or the
nlatwf leiurer's representative. The: ANVWTS shall be maintained ill a satisfactor.\
condition capable ofperfornung as designed and producing treated septic effluent in
accordance with the equipment's approval for operation in the NIauaicipality.
It shall be tile, responsibility of the Owner during the terns of this Agreement to pay for all
repair(*). maintenance, adistinetlt(s), rel)lacenletlt cost*, :and inspection costs. TMS
includes an annual maintenance tee (typically $400 to $600).
()wncr agrees that only maintenance and repair pe►-sontael approved by the Nlaniciparlih'
or the nlnnufacturer's representative will inspect and make any neccssaxti� maintenance,
repairs or permitted alterations to the *'stet».
Owner acknowledges that regular maintenance of an A\\'\\* S reduces the potctitial
failure of the system, which could ilie ltitle sewaage backup and costly repairs or drainheld
replacement.
(rev. 0S/18/201K) Parc 1 of
Owner acknowledges that the Municipality may request records of maintenance and
repairs from the manufacturer's representative or maintenance provider.
Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be
assessed in accordance with AMC 14.60.030.
Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS. The Municipality will give at least 24-hour notice.
Owner agrees that any sale or transfer of title of the property will not occur without a new
Certificate of On -Site Systems Approval.
Owner agrees that the AWNNITS installation and maintenance requirements as provided
by the AWWTS vendor/installer and approved by the Municipality are the governing
guidelines for the construction, maintenance and repair of the Owner's AWWTS.
Owner agrees to maintain remote monitoring of the AWWTS as required by the
AWWTS approval.
3. Term. The term of this Agreement shall begin on the date of approval by the
Municipality to operate the installed system, or upon transfer of title, and shall continue
while the AWWTS is operational or until title is transferred.
4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this
Agreement shall in no way constitute a waiver of the provisions, nor in any way affect
the validity of the Agreement or any part hereof, or the right of the Municipality
thereafter to enforce every provision hereof.
5. Amendment. This Agreement shall only be amended by authorized representatives of
the Owner and Municipality. Any attempt to amend this agreement by either an
unauthorized representative or unauthorized means shall be void.
6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be
brought in the Superior Court for the Third Judicial District of the State of Alaska at
Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the
parties under this Agreement.
7. Severability. Any provisions of this Agreement decreed invalid by a court of competent
jurisdiction shall not invalidate the remaining provisions of the Agreement.
(rev. 05/18/2018) Page 2 of 3
OWNER:
By: _ (sib nature. Date:
LUjel---le(print name)
S-1-ATi or' A )
SS.
1IIIRD JUDICIAL DISTRICT )
The Ioregoin 7 instrument was ackno«•lcd�-,cd before me this''dav of
N0TAIZPI I ILS C 1'OR A+,- [�r� AL1
My Convnissi I expires: 7-14 z
MUNICIPALITY:
BY: l{% (signature)
(print name)
Date: E ZZ._.
Title:
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phopa�(907)-343-7904 Fax: (907) 343-7997
http://w ,%, muni.oro/onsite
On -Site Was
Permit Number: OSP221073
Work Type: Septic Initial
Tax Code Number: 01122123000
Site Legal Address
Iter Disposal wSystem Per it
Oe �(�
1'�e )v Date:
xpi ion Date
SEACLIFF BLK � LT 22A G:2424 01,
Site Mailing Address: 5112 Shorecrest qR, Anchorage
Owner: MANN MATTHEW &
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy
1�1 c n t
n r^
n
v.
Departin ent
4/29/2022
4/29/2023
Lot Size in Sq Ft: 19287
Total Bedrooms: 4
❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions:
1. Septic system installation must meet the requirement of the ADEC for the well waiver.
2. The private sewer line shall maintain 100 ft separation to the public water system, as shown on the
engineer's site plan.
3. Prior to Inspection Report approval, a full approval for the well separation from the ADEC is required to be
submitted to Onsite.
4. The Onsite inspector must be at the bottom of hole excavation for the trench to confirm insitu soils are
sand.
Received By:
Issued By:
Date:
Date: y Q Z
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 011-221-23
Property owner(s) Matthew Mann & Erika Wessel Day phone (907) 301-5359
Mailing address 2611 W 100th Ave, Anchorage, AK 99515
Site address NHN Shorecrest Drive
Legal description (Sub'd., Block & Lot) Seadiff, Block 1 Lot 22A
Legal description (Township, Range & Section)
Lot Size 19,287 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
0
Initial EX -1
Single Family (SF) ❑X
ADU)
Septic Tank
❑X
Upgrade 1-1(w/wo
(D) El
Holding Tank
❑
RenewalDuplex
❑
Multiple
Multiple Dwellings ❑
Privy
El
and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION
INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
i
(Signature of property owner or authorized agent)
Permit/Rush Fees: J 5 Waiver Fees:
Date of Payment: Q0 �2 a Date of Payment:
Receipt Number: 0 1 D/ Receipt Number:
Permit No. CS P a a 1 U Waiver No.
Permit App_::- : -
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
pOBox 1gaas0 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
On -Site Wastewater Disposal System Permit
Permit Number DSP211087
Work Type: Septic Initial
Tax Code Number: 01122123000
Site Legal Address: SEACL|FFBU< Y LT 22A G:2424
Site Mailing Address: 5112Shoneorem1DR, Anchorage
Owner BURY JOHN C&SUSAN K5U%&
Design Engineer: G/\RNESSENGINEERING GROUP LTD
This permit imfor the construction of:
Effective Date:
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms
4/8/2O21
40/2D22
2Disposal Field RISeptic Tank [] Holding Tank El Privy [] Private Well [] Water Storage
All construction shall beinaccordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (1OAACG0)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65.Provide notification bycalling (0O7)343 -79O4(24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall beeither:
o. Opened and Closed onthe same day, or
b. Covered, sealed, and heated to prevent freezing
IN
Special Provisions:
1. Tank installed must meet the requirement oythe ADECfor the well waiver.
2. The future house must meet the required separation to the septic system and building setback.
3. Prior to Inspection Report approval, a full approv al for the well separation from the ADEC is required to be
submitted tuOnsite.
4. The Onsite inspector must beetthe bottom ofhole excavation for the trench t000nfinninnibusoils are
sand.
Received By:
Issued By:
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Fax: 907- 343-7997
On -Site Water & Wastewater Program
Mayor Austin Quinn -Davidson
On -Site SewerMell Permit Application
For A Single Family Dwelling
Parcel I.D. 011-221-23
Property owner(s) John Bury Day phone 907-349-8754
Mailing address 5142 Shorecrest Dr. 'Anchorage, AK 99502
Site address 5112 Shorecrest Dr. *Anchorage, AK 99502
Legal description (Sub'd, Block & Lot ) Seacliff; Block 1, Lot 22A
Legal description (Township, Section & Range)
Lot Size
APPLICATION IS FOR:
TYPE OF DEWELLING:
( ® all that apply)
Single Family (SF)
Absorption Field
Upgrade ❑
Septic Tank
Holding Tank
❑
Privy
❑
Private Well
❑
Water Storage
❑
Sq.Ft. Number of Bedrooms 4
APPLICATION IS AN:
TYPE OF DEWELLING:
Initial ®
Single Family (SF)
Upgrade ❑
(w/wo ADU)
El
Duplex (D)
El
Multiple Dwellings
❑
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR:
All waivers are through ADEC Distance
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 5�'J S Waiver Fees:
Date of Payment: _� '2-f Date of Payment:
Receipt Number: [ti Lj i 6 Receipt Number:
Permit No. �Sp Z I I() 8 7 Waiver No.
(Rev. 01/11)
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211087, Deb Wockenfuss, 04/08/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211087, Deb Wockenfuss, 04/08/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211087, Deb Wockenfuss, 04/08/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211087, Deb Wockenfuss, 04/08/21
Lang & Ass
11500 Daryl Avenue
(907) 522-6476
0 F
A
491h
........ .....
N
j"
I'S
SIONAC
Registered Professional Land Surveyors
Anchorage, Alaska 99515-3049
(907) 522-4625 Fox
SURVEY REPORT
SEACLIFF SUBDIVISION
Lot 22A, Block 1
(Plot No. 73-68)
Z'2
10' UTILITY EASENIENT_�' ___1
FOUND 4" REBAR-/
Lot 21
EDGE OF ROAD ASPHALT *� /
RE /f
/-POWER POLE D R
LWATER WELL I
> TRACT
19, WELL
NEIGHBOR'S GRAVEL
DRfVEWAY ENCROACHES
TEST HOLE
FOUND REBAR
FOUND I" IRON PIPE
ON PROPERTY LINE
TOP OF BLUFF
Lot 22A
19,287 S.F.
SET SPIKES AT
PROPERTY
CORNERS
6A9 16'
0
BOTTOM OF BLUFF
EDGE OF LAWN BEING
MOWED BY LOT 23A
,,�FOUND J" REBAR
ON PROPERTY LINE
-CHAIN -LINK FENCE
Lot 23A
GOVERNOR NfIC-FLUL J, DUNLF—AIPf
March 23, 2021
John & Susan Bury
Owner of Lot 22A, Block 1, Seacliff S/D
5142 Shorecrest Drive
Anchorage, AK 99502
johnburyak@gmail.com
Re: Seacliff Subdivision, Block 1, Lot 22A
Drinking Water Separation Distance Waiver
Dear Owners of Lot 22, Block 1, Seacliff Subdivision:
` 1 1
DIVISION OF ENVIRONMENTAL HEALTH
Drinking Water Program
555 Cordova Sfreet
Anchorage, Alaska 99501
Main: 907.269.7623
Fax: 907.269.7650
dec.alaska.gov
File: Sand Lake Services
DEC Project ID: 16714
PWSID: 210485
Class: Community
Source: Groundwater
This office received an updated submittal from Gayness Engineering Group requesting a waiver
from the 200 -foot required separation distance between a public water system drinking water well to
a proposed onsite wastewater disposal system on Lot 22A, Block 1, Seacliff Subdivision. This letter
issues a Conditional Separation Distance Waiver for the requested reduction of the State's
minimum separation distance requirement between drinking water wells and sanitary sewer
components, as detailed in the submitted engineering information and outlined below.
Project Description
This property is located on Shorecrest Drive and backs up to the bluff along Turnagain Arm.
Many lots in this area are served by the Sand Lake Services Public Water System, PWSID 210485, or
other drinking water wells, and they have individual sewer systems,typically onsite septic tanks and
drainfields.
Two of Sand Lake PWS's groundwater wells are nearby (Wells #1 and #3). The majority of Lot 22
is within the 200 foot protection radius around both wells. The only portion outside of 200ft is the
steep bluff dropoff to the coastline.
Well #1— Drilled May 9, 1964 to a total depth of about 212 feet. Cased to 206 feet.
Well #3 — Completed February 11, 1995. The well log (WELTS #23107) shows it was grouted, and
that it was cased to 525 feet with the intake screen starting at 513 feet.
This property proposes to install a septic tank and trench drainfield, and is requesting to place them
within the 200ft separation distance, but no closer than 120 feet to the Sand Lake PWS wells. The
wastewater system must be installed by a person that meets the requirements of 18 AAC 72.015 and
component details include:
- Septic tank: 1,500 gallon, dual compartment, polyethylene, single piece construction
- Drainfield: deep trench, 500 fe minimum, maximum depth 12 feet
o Space for a backup drainfield is available towards the bluff which would require
installation of a pump/liftstation and waiver of bluff setback requirements
Page 1 of 3
Seacliff S/D, Block 1, Lot 22A 3/23/2021
Limitations
This determination was based on current site conditions and well information available to the
Department. Occurrences of floods, earthquakes, and human activity can change the geophysical,
chemical, and biological conditions under which this determination was made. This determination
does not preclude the Department from reevaluating this separation distance waiver in the event such
conditions change or additional information becomes available to the Department that would warrant
further review.
Approval of this waiver does not obligate the department to approve future waiver requests
proposing the same design, is not an approval of omissions or oversights, and does not guarantee
correctness of the functional design or waive the owner's responsibility for continued compliance
with state, federal, and local regulations.
APPeal Process
The applicant, owner or operator, or other person adversely affected by this decision may request an
informal review of this decision in accordance with 18 AAC 15.185, or may request an adjudicatory
hearing in accordance with 18 AAC 15.195-15.340. Requests may be sent by mail, email, or facsimile.
Informal review requests must be received by the Division Director within 20 days of this decision.
Adjudicatory hearing requests must be received by the Commissioner within 30 days of this decision
or the decision of the informal review issued by the Division Director; otherwise, the right to appeal
is waived. For more information, visit https://dec.alaska.gov/commish/review-guidance.
If you have any questions, please contact me at 907-269-7516 or darlene.galido@alaska.gov.
Sincerely,
Darlene Galido, P.E.
Engineer I, DEC
Cc: Sand Lake Services PWS 210485 Owner: Homewater LLC, homewaterllc@hotmail.com
Sand Lake Services PWS 210485 Operator: Northern Utility Services, dave@nusalaska.com
Owner Seacliff SD Block 1 Lot 22A: Katharine LaForest, katharine907@gmail.com
Garness Engineering Group: Jeff Garness, P.E. jeff@garnessengineering.com and
Pierce Blewett, P.E. pierce@garnessengineering.com
210323 Seacliff SD_Blockl_Lot22A - Waiver Sand—Lake-210485 WA.docx Page 3 of 3
municipality of Anchorage
f { �
'T 6i • Tc.VL:c (90 907) 343.8-0(X)
PO.9m 19(65)•rV:chomp, laska 510 m
s• r.r.
3700 limgaa• Strccl • ,Vuhorngc, AInslm S)!"7
mim.munl.org
Dlagor Mark Begich Iluilding Safety Division
September 13, 2005
John & Susan Bury
717 Winter Haven Street
Anchorage, AK 99504
Subject: On -Site Water and/or Wastewater Permit.
Permit Number: SW040434
Legal Description: Seacliff Block 1 Lot 22A
Dear Mr. & Mrs. Bury:
An On -Site Water/Wastewater Permit, number SW040434, issued by this office for a single-family
system, will expire on October 18, 2005. The permit is valid for 365 calendar days.
If this was a well permit and the well has been drilled, a well log must be sent to this office for
documentation of the installation and to close the permit.
If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to
this office for review, approval and documentation. This as -built inspection report must be signed by
the licensed Professional Engineer who inspected the installation of the system. As -built inspection
reports are required to be submitted within 30 days of the completion of the system.
If no system was installed under this permit, and you are still planning to install a well or wastewater
disposal system, a new permit must be obtained from this office. A new permit for a second year may
be issued for a fee of $115.00 if the renewal application is received on or before the expiration date of
the original permit.
When applying for a new permit, the fees are: $460.00 for a wastewater permit and $175.00 for a well
permit.
If you have any questions, please call this office at 343-7904.
Sincerely
Nt I P
Daniel J. Roth
Program Manager
On -Site Water and Wastewater Program
Enc: Copy of permit
C011111111nity� Secltrity, Prosperity
Permit Number: SW040434
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Renewal
Legal Description: Seacliff Block 1 Lot 22A
Design Engineer: 0855 Gamess Engineering Group, LTD
Owner Name: John & Susan Bury & Katherine LaForest
Owner Address: 717 Winter Haven Street
Anchorage , AK 99504 -
Date Issued: Oct 18, 2004
Expiration Date: Oct 18, 2005
Parcel ID: 011-221-23
Site Address: 5112 Shorecrest Drive
Lot Size: 19287 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit Is for the construction of:
Disposal Field ❑✓ Septic Tank Holding Tank ❑ Privy Private Well Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling
(907) 343-7904 ( 24 hours). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Date: (0 11 0
Date: 9 0•
\ Municipality of Anchorage
1 Development Services Department e`
Building Safety Division
On -Site Water and Wastewater Program s .
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907)343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. hit — - 2 Permit Number SW r
Property owners) t 44ay phone�
Mailing address S \ _ � Zip Code GgsOa
Site address � � 1, g, :��!`e CQ`� l ��S" Zip Code ��S W;
Legal description (Lot, Block & Sub'd.) �eGC.�.�
Legal description (Section, Township & Range)
1
Lot Size' 1 O9cM/Sq.Ft.
Number of Bedrooms r 1
THIS APPLICATION IS FOR:
Sewer Only
❑l_�
Well Only
❑
Sewer and Well
❑
Water Storage
❑
Sewer Upgrade
❑
THIS PROPERTY CONTAINS:
Hot Tub
❑
Jacuzzi
❑
Swimming Pool
❑
Water Softening Unit
❑
Therapy Pool
❑
certify4at t ve 'r forma ' rrfs correct. I further certify that this application is being made for a
Single rn Ili is in accordance with applicable Municipal Codes.
Permit/Rush Fees: KVPELL,4L7//.4 Waiver Fees:
Date of Payment: 10112-104- Date of Payment:
Receipt Number: 057Y 57 Receipt Number:
(Rev. 09/04)
Permit Number: SW030491
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: Nov 25, 2003
Expiration Date: Nov 24, 2004
Parcel ID: 011-221-23
Legal Description: fSeadiH Block 1 Lot 22A'
Design Engineer: 0041 AK Water & Wastewater Consultani Site Address: 5112 Shorecrest Drive
Owner Name: Sandy Sherwood Lot Size: 19287 SO. FT.
Owner Address: 717 Winter Haven Street Total Bedrooms: 4 Permit Bedrooms: 4
Anchorage . AK 99504 -
This permit is for the construction of.
❑Q Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be In accordance with:
1. The attached approved design.
2. All requirements specked In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
(ter 4ya=k Date: // Z2, In �
Date: 111.2 5 0j
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 South Bragaw SL
P.O. Box 196650 Anchorage, AK 99519-6650
www.cf.anchorage.ak.us
(907)343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. () II —Z -0 —Z 3
Property owners) SANDY SHERWOOD
Mailing address (1) 717 WINTEF AVEN .EE)* • ANCHORAGE, AK
Mailing address (2)
Permit Number 57lNO'�C4%
Day phone
Zip Code
337-4692
99504
Legal description (Lot, Block & Sub'd.) SEACLIFF SUBDIVISION: LOT 22A, BLOCK 1
Legal description (Section, Township & Range) �' SI I Z S "-by'u: rLS+
Lot Size `I i nl Acre Sq.Ft. Number of Bedrooms 4
THIS APPLICATION IS FOR:
Sewer Only 0 Well Only ❑
Sewer and Well ❑ Water Storage ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi ❑
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal codes.
ALASKA WATER & WASTEWATER CONSULTANTS, INC.
Permit Fees: kH no Waiver
Date of Payment: Date of Payment:
Receipt Number: LI �/ "t 1 C ' \ Receipt Number.,
ALASKA WATER & WASTEWATER
�•�+�+� -----.�a..�.,�....r. CONSULTANTS, INC. —
November 13, 2003
Municipality of Anchorage
Development Service Department
Building Safety Division
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
Ref: Proposed Septic System for Lot 22A, Block 1; Seacliff Subdivision
ADVANTEX"' TREATMENT SYSTEM
To whom it may concern:
1. GENERAL: The proposed 4 bedroom home will be served by a public water system and a
private septic system. A test hole was excavated on the property. We are proposing to design the
septic system around the 30 foot radius of this lest hole. Due to the cutbank to the south, we are
proposing to use an Advantex treatment system and a deep trench type drainfield.
2. SOILS: See the attached log, which shows the soil classifications, groundwater monitoring,
and the percolation test results.
3. DRAINFIELD APPLICATION RATE: The intent is to install an Advantex Treatment
System that will allow the use of a small drainfield in the area around the 30 foot radii of the test
holes. The Advantex system has received class III approval and we are going to conservatively
assume an application rate of 3.0 GPD/FT2.
4. TRENCH DESIGN:
a. Percolation Rate: <1 minutes/inch
b. Allowable Application Rate for Class III System: 6.0 gallons/day/fl
c. Proposed Application Rate: 3.0 gallons/day/R2
d. Number of Bedrooms: 4
e. Design Flow: 600 gallons per day
f. Minimum Absorption Area: 200 n2
g. Total Depth: 12 feet (max.)
h. Effective Depth: 7.0 feet
i. Width: 2.5 feet
j. Minimum Length: 15 feet long
k. Effective absorption area: 210 flZ
3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507
Ph: (907)337-6179 • Fax: (907)338-3246 • Website: www.akwwc.com
5.ORENCO PACKAGE SYSTEM: The STEP tank with the Advantex Treatment System will
be manufactured by Anchorage Tank & Welding to meet the latest design criteria established by
Orenco Systems, Inc. The point of contact at Anchorage Tank is Lowell McNutt. As with their
standard STEP tank, it is equipped with a high water alarm per M.O.A requirements.
6. SURFACE WATER: There is no surface water within 100 feet of the proposed septic
system upgrade.
7. TOPOGRAPHY: As can be seen on the attached design drawing the average topography in
the area of the proposed drainfield is relatively flat. There is a steep bluff approximately 45 feet
south/southwest of the test hole. We request that a 35 feet separation distance waiver from the
top of this slope to the proposed drainfield be granted. Given the porosity of the soils there will
be a great amount of lateral movement and minimal horizontal movement. In short, there is
minimal risk with the granting of this waiver.
8. WAIVER TO CLASS "A" WELL: There is a class "A" well to the north east of the
property. We a have recently obtained a 140 foot waiver to the class "A" well to the proposed
septic system.
9. DISINFECTION SYSTEM: Due to the proximity of this system to the above well, we are
required to install a disinfection system per the A.D.E.C. waiver. We are proposing to install a
Sanuri) disinfeciton unit and a chlorine contact manhole in the line to the drainfield.
10. CLOSING: I am open to any suggestions from your department that would be an
improvement to the proposed system. I am unaware of any negative impacts that this installation
would impose on adjacent wells, or septic systems. If you have any questions, please call us at
M.S.
NOTE: Attached is a site plan drawing, a design drawing, an Advantex detail, a trench detail, a
soil log, and a 7 page construction specification letter which are all part of the design package
for this septic system.
3701 E. Tudor Road, Suite 101 . Anchorage, AK 99507
Ph: (907)337-6179 • Fax: (907)338-3246 w Website: www.akwwe.com
FRANK H. MURKOWSKI, GOVERNOR
555 CORDOVA
DEPT. OF ENVIRONMENTAL CONSERVATION ANCHORAGE. AK 99501
Phone: (907)269-7519
DIVISION OF ENVIRONMENTAL HEALTH Fax: (907) 269-7650
DRINKING WATER AND WASTEWATER PROGRAM 269-7650http://www.state.ak.us/dec/
October 31, 2003
Jeffery A. Garness, P.E.
Alaska Water & Wastewater
3701 E. Tudor Road, Suite 101
Anchorage, Alaska 99507
Re: Seacliff S/D, Block 1, Lot 22A- Request for a Separation Distance Waiver Between a
Class A Public Water Source and a Proposed Soil Absorption System,
PWSED # 210485, ADEC Project # 3624,
Dear Mr. Gamess:
The Department has reviewed your request for a waiver received on October 16, 2003 between
the existing class A public water system and a proposed Advantex wastewater treatment system
that discharges to an on -lot soil absorption system that serves a 4 bedroom single family house.
According to your submittal the soil conditions are rated as sand. The home is designed with a
1500 gallon advance system with a design flow of 600 gallons per day. The absorption field is
sized at 210 square feet, based upon a design application rate of 3 gallons per square foot per day.
The separation distance requested from the class A source well to the replacement field, and the
proposed drain field is 140 feet. The advantex unit is to be located at a scaled distance of 150 feet
from the source well. The lot also has a cliff that is located 35 feet from the proposed drain field
which will also need to be waived to allow the development to proceed.
Waivers
Your requests for waivers between the Class A public water source and the proposed on -lot
wastewater system along with a review of the well logs, soil reports, current water sample results,
and the plan drawings has taken place. Based on the information submitted, it appears the waiver
requests are protective of public health, therefore, in accordance with the State Drinking Water
Regulations (18 AAC 80.020), the following waivers are granted with two conditions that will
follow after the waiver descriptions.
The separation distance between the Class A public water well located near Endicott
Street and Shorecrest Drive and both the proposed soil absorption system and the
replacement soil absorption system serving the home on lot 22A, Block 1, Seacliff
Subdivision are waived from 200 feet to 140 feet.
The separation distance between the Class A public water well located as stated
above and the Advantex treatment on Lot 22A, Block 1, Seacliff Subdivision has
been waived from 200 feet to 150 feet.
The separation distance between the top of the cutbank and the proposed on -lot soil
adsorption system has been waived from 50 feet to 35 feet.
Conditions placed on the waivers are as follows:
1. that the waste stre�benfected2. that annual inspecs ted to this office.
The distances noted in the waivers are from your submittal. It appears that these distances are
from the nearest edge of the wastewater disposal system component to the nearest edge of the
existing Class A public water system well or the top of the cutbank. If any wastewater disposal
system fails or contamination can be traced back to the system, the waivers will be invalid.
This approval does not imply the granting of additional authorizations nor obligate any state,
federal or local regulatory body to grant required authorizations.
Any person who disagrees with this decision may request an adjudicatory hearing in accordance
with 18 AAC 15.195- 18 AAC 15.340 or an informal review by the Division Director in
accordance with 18 AAC 15.185. Informal review requests must be delivered to the Division
Director, 555 Cordova St., Anchorage, Alaska 99501, within 15 days of the permit decision.
Adjudicatory hearings requests must be delivered to the Commissioner of the Department of
Environmental Conservation, 410 Wiloughby Avenue, Suite 303, Juneau, Alaska 99801, within
30 days of the permit decision. if a hearing is not requested within 30 days, the right to appeal is
waived.
Thank you for your cooperation. Please place the ADEC project number 3624 on all future
correspondence regarding this project. If you have any question please do not hesitate to contact
me at 269-7519.
Respectfully, ) r
William R. Rieth, P.E.
Environmental Engineer
cc: David Johnson, DWIWW,
ALASKA WATER & WASTEWATER
CONSULTANTS, INC.
November 11, 2003
State of Alaska f —"e -A "-�. 'r, —
Department of Environmental Conservation NOV 112003
Division of Environmental IIealth
Drinking Water &- Wastewater Program
Attn: Bill Rieth, P.E.
555 Cordova Street
Anchorage, Alaska 99501
Subject: ADEC Project #3624. Septic System Upgrade at Seacliff S/D, 22A, Block 1
Dear Mr. Rieth,
In order to comply with your October 31, 2003 letter, which granted waivers that were necessary
to install the subject septic system, we are proposing to install a chlorine disinfection system.
The proposed system will be a Sanuril, tablet type, chlorinator in a manhole between the
Advantex system and the pump vault, followed by a chlorine contact tank. As the effluent from
the Advantex system flows to the pump vault, it will pass through the Sanuril unit where it will
come into contact with the chlorine tablets. The chlorinated effluent will then flow through a
contact tank (buried fiberglass basin with access manhole). The contact tank piping will be
plumbed in the bottom and out the top so as to maximize the contact time. Effluent from the
contact tank will then flow into the pump vault, where it will be transferred to the drainfield for
final disposal. We are requesting your concurrence regarding the proposed disinfection system.
If you have any questions, or require additional information, please contact me at 337-6179.
Thank you for y9F assistance and consideration in this matter.
P.E., M.S.
3701 East Tudor Road, Suite 101 • Anchorage, AK 99507
Ph: (907) 337-6179 • Fax: (907) 338-3246 • Website: akwwc.com
�N 11/13/03 08:20 FAX 9072897850 DEC DR&RW 001
�in �N'ov.11. 2003 10:31AM No -1018 P. I
ALASKA WATER Ftr WASTEWATER
CONSULTANTS, INC-
November 11, 2003
State of Alaska �l
Department of Environmental Conservation
Division of Environmental Health
Drinking water & wastewater Program
Attn: Bill Rieth, P.E.
555 Cordova Street ` D�
Anchorage, Alaska 99501 M
Subject: ADFC Project 113624. Septic System Upgrade at Seaditf S/D, 22A, Block 1
Dear Mr. Rieth, /V \•
In order to comply with your October 31, 2003 letter, which granted waivers that we necessary
to install the subject septic system, we arc proposing to install a chlorine disinfc vn system
The proposed system will be a i tablet chl ' ator in a manhol een the
Advantcx system and the pump vault, followed by a chlorine contact tank. As the effluent from
the Advantcx system flows to the pump vault, it will pass through the Sanuril unit where it will
come into contact with the chlorine tablets. The chlorinated effluent will then flow through a
contact tank (buried fiberglass basin with access manhole). The contact tank piping will be
plumbed in the bottom and out the top so as to maximize the contact time. 13flluent from the
contact tank will then flow into the pump vault, where it will be transferred to the drainfield for
final disposal. We are requesting your concurrence regarding the proposed disinfection system.
If you have any questions, or require additional infomtation, please contact me at 337-6179.
Thank you for ypprr assistance and consideration in (his matter.
P.1:., M.S.
3701 Fast Tl:der Road Suite 101 • Anchorage, AK 99507
Ph: (907) 337-6179 •lax: (907) 338-3246 • Websitc: al,•wwc com
RECENM
NOV 12 2003
A,t1ZC/ ncho'rroe
Emy'.ronrnen:al Heim
\ SEACUFF S/D
LOT IQ& BLOCK 1
�\ SEACUFF S/D
LOT 9A. BLOCK 1
\R/lo
SEACUFF S/D
LOT 19, BLOCK 1
PROPOSED SEPTIC SYSTEM T'
(SEE DESIGN PACE 2 OF 4)-I-�
SEACUFF B SCK /LoST021.
T
LOT 20, BLOCK 1
CUFF S/D 1
BLOCK 1
T12N, R4W, SECTION IS, PARCEL 11,
SEACUFF S/0
LOT BA. BLOCK 1
i
I TH/I
SEACUFF S/O
T 23A, BLOCK 1
10/7/2003
ALASKA NATER & «'ASTEIN'ATER C.J.G.
CONSULTANTS, INC. SCALE -*
c 100)
vel a Tllen: Feng GUTe dei . p,q.N'.oAGe Cc o0[0) • 0.,n4e lOnT.t f-n�)(1 • enf lon)mn-Pl.t,
PREPARED FOR PHONE NUMBER: PACE NUMBER:
SANDY SHERWOOD 337-4692 1 OF 4
SEACLIFF SUBDIVISION; LOT 22A, BLOCK 1
OF WORK:
SITE PLAN FOR PROPOSED SEPTIC SYSTEM AND WAIVER
1
I 1
I I
I I
! 1 I
1 1
/ CLASS A'�
/ COMMUNITY/
WELL /
i
ij/.7JJ
�nt�djD�o f essio�°
ALTERNATE SITE —�
PROPOSED DRUNFIELD. EXCAVATE A
TRENCH THAT IS 12 FEET DEEP BY
2.5 FEET WIDE BY 15 FEET LONG.
ADD 7 FEET OF CLEAN, WASHED
SEWER DRAINROCK. INSTALL TRENCH
PARALLEL TO SLOPE COMOURS.—
�J1�09 CHLORINE
�IN BOTTOM
TMf.'t'
MANHOLE WITH SANURIL\
UNIT PLUMBED INSIDE \
rum To=
/ \ I
CT MANHOLE. \ \
OUT TOP \
—PROPOSED 1500 GALLON \
ADVANTEX TREATMENT
SYSTEM r/ PUMP VAULT
\
\ TOP OF CUTBANK
10/7/2003
DRAWN BY:
C.J.G.
ALASKA WATER R WASTENVATER SALE
CONSULTANTS, INC. 1 = 40�
3701 F TUOOR ROA°. SURF 101 • ANCNWIAGF. AK 00507 • PNONF (001)337.61M • FAX (007A1P-3746
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
SANDY SHERWOOD 337-4692 2 OF 4
LEGAL DESCRIPTION:
SEACLIFF SUBDIVISION; LOT 22A, BLOCK 1,
TYPE OF WORK:
DESIGN DRAWING OF PROPOSED SEPTIC SYSTEM AND WAIVER
..... ... .. .. ......
Je a '^ .5.:...
C —7953 •. `Fv
T'FolessioA°oma
�440000�0
I
NOTE: JIM CRO55,
P.E. 1415 THE
ADVANTEI( MANUAL
AdvanTe)C Treatment System
AX20 -Mode l a '?z
40x94Pod ="
PROPOSED DRAINFIELD
rzr-q
v JIM
6' PVC PUMP -Off
9* PVC COUPLING
�!� iilil
CLUED TO TANK
■ 40.4 �
INLET
OPTIONALTO PRWOE
� V1�11y
�,■0
D'�•
rMM
a
10/7/2003
DRAWN BY: C�
ALASKA NVATKR & WASTE NVATRR j.G. ooh:
CONSULTANTS, INC. SCALE. N.T.S.O e
5701 F TUDOR ROAD. SUITE 101 • ANCNORAGF. AK 00507 • P ONF (00))35]-0170 • FAX (007)35A-StA6O
REPARED FOR: PHONE NUMBER: PAGE NUMBER:
MIKE POLZIN (907) 248-6921 3 OF 4
EGAL DESCRIPTION: QO n
U.S. SURVEY 3042: LOT 84F 0041
YPE OF WORK: Q
DETAIL DRAWING OF ADVANTEX TREATMENT UNIT
ORENCO
BIOTUBE
SCREENED
VAULT
PUMP
t
C 7953 `F`O�
13' LONG
---------------------------
MT I
I FROM ADVAiTEX
+ I MTO 1 TREATMENT SYSTEM
DEEP TRENCH
GRADE
FABRIC
1140,14
OF EFFECTIVE
.. ....IQ: o� O
10/7/2003 0� 0
DRAWN BY: vO �1
ALASKA WATER & WASTEWATER C.J.G.SCAL
CONSULTANTS. INCE °
3701 F TUDROAD. SUITE IOI • ANCHORAGE. AK 99501 • PHONF (90))331-6179 • FAX (907MM-SRS
N.T.S. �......... ...............
OR
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: O
SANDY SHERWOOD (907) 337-4692 4 OF 4 et a A. am ss;'
LEGAL DESCRIPTION: oO� j C —795 .•.. `a�
SEACLIFF SUBDIVISION; LOT 22A, BLOCK 1,
TYPE OF WORK: De PFO •••••••' ;�Co�
iessl0�°o0
DETAIL DRAWING OF PROPOSED DRAINFIELD �4400000�
�qO OO
/ C
ALASKA AVATKR & WASTK�VATKR
CONSULTANTS, INC. 0 �'
SOIL LOG - PERCOLATION TEST D
LEGAL DESCRIPTION: SEACUFF SUBDMSION; LOT 22A, BLOCK 1 ,p ••.J fr A rness.: O
PERFORMED FOR: SANDY SHERWOODpgTE; 9/2/2003DEPTH
C —7953
(t et) TEST HOLE 1 pp�44p'otess}000�
40000
ORGANICS, SOIL CLASSIFICATIONS
2 ____ OLD FILL, i
---- & SILTY q.,<;o GW cc== ORG cs—ip�c
3 _ SAND •.;.; GP I ML
=.c. GM 717171 CL 1
4 ==== GC OL 1
•i•00 o° "°° e" SW MH SEACUFFIS/D THI1
'•o^''•�•• SP CH LOT 21, BLOCK 1 .�
5 • .o a
i• °o •l SM / i OH .Q
• eoa
**Do* SC
6— •..°o°
••ooe � P
••.o°o° V�•t'
7 •••o°� DEPTH TO �� o
0'00 GROUNDWATER DATE tio
•° 3
••.o°°°
..•000
8 00000 DRY 9/2/2003 `.
e
��o°oe DRY 9/11/200 ��, '
9 ,000
.• 008 SITE PLAN
••00°0
�•• oo e 1 •� 100
10—•''O°O
4•e0°O
::• 000
11 • ro°o°
SP TO SW
000000
.• p00
•'•o°o
0••000
•• 00°0
.• ooe
13 •••O°o°
•10 coo ro°o°
•.• oo u
14 •••.o°a
••oo°o
.• 000
15 •''O°O
••pOo
••00°0
�.• 000
16 ::°°0,
000
'• 00°0
�•000
17 • .o°o°
•ooe
• .o°o°
••ooe
18 . ° 0
• B.O.H.PET
19 PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN 7.0 FT. AND 7.5 FT.
20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES NO
SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: SUSAN OSWALT
COMMENTS: THE INSITU SANDY SOILS SHOULD ACT AS A SAND FILTER
PERFORMED BY AKWWC, INC. 1, JEFFREY A. GARNESS, CERTIFY THAT THIS W S ERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
DATE READING CLOCK NET TIME WATER LEVEL NET DROP
TIME (MINUTES) READING (INCHES)
9 2/2003 1 1:01 — 6-
12--
—
2
1:05
4
0•
6'
3
1:06
—
6'
—
4
1:11
5
0'
6°
5
1:11
—
6•
—
6
1:16
5
0'
6'
7
1:16
—
6•
—
8
1:21
5
0e
6°
9
1:22
—
6•
—
10
1:26
4
0e
6°
11
1:27
—
6'
—
12
1:31
4
0'
6'
GREATER ANCHORAGE AREA BOROUGH
5�P PN�NORgpF 4qP HEALTH DEPARTMENT
P O 9a NEW ADDRFSS. �__
oy �r-,—�r-^o-'rs«�— O P.O. BOX 968
327 Eagle S.{"TERt 'ANCHORAGE. ALASKA 99501
i PHONE 272-6467
a;y January 30, 1968
SUBJECT: Installation of On -Site
Sewage Disposal System - Lot 22A,
Block 1, Seacliff Subdivision
TO WHOM IT MAY CONCERN:
The Greater Anchorage Area Borough Health Department will approve the
installation of adequately sized, properly constructed septic tank -
seepage pit, on-site sewage disposal system to serve the subject lot
provided that the system can be installed outside of the well protection
radius as described in the Seacliff Subdivision Easement Miscellaneous
Book 85, Page 185, Anchorage Recording District 64-9837.
Preliminary design for the proposed system shall be submitted to the
Borough Health Department for review and approval prior to any
construction or installation, and all construction shall be inspected
by the Greater Anchorage Area Borough Health Department prior'to
backfill.
Said system shall not be used until final inspection and approval
have been given by this office.
Sincerely,
DAVID R. L. DUNCAN, M. D.
Medical Director
BY: / ate«✓
Clif d P. Judkin , R. S.
Chi Sanitarian �!
CPJ/srr
cc: Mr. Edward Powell, Small Business Administration
Mr. R. J. Rhodes
a'
J
AIR MAIL TO ALASKA IS FASTER