HomeMy WebLinkAboutSEQUOIA ESTATES BLK 2 LT 61 v: ,�, C)tamm) - I salwab Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181311 . PID Number: 017-152-20 Dwelling: 0 Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New F91 Upgrade Name: Carl Kopp ABSORPTION FIELD ❑ Deep Trench F91 Shallow Trench ❑ Bed ❑ Mound Address 6720 Spectrum Cir, Anchorage, AK, 99516 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 244-1632 3 0.8 GPD/SFJ 7.5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4.5 Ft. Gravel depth beneath pipe 3.0 Ft. Subdivision Block Lot Sequoia Estates 2 6 Fill added above original grade 0.0 Ft. Gravel length 66.0 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 569 Ft 1 Ft. Well N/A >100' N/A N/A >25' TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity Surface water N/A >1 00' N/A N/A Gal. Material Number of compartments Lot Line N/A >10' N/A N/A NA Foundation N/A >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Replacement field only Pump on level at in. Pump off level at in. High water alarm at in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank Exist. Tank to D3034 drainfield Installer A+ Home Services Drainfield D3034 CO/MT Inspector B. Schiller / J. Williams BENCH MARK (Assumed elevation) 100 ft Inspdection 15' 9/27/18 9/28/18 Location and description 2�d 3'd 4'h Threshold of lower level back door. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp F � Conditional Approval: Date ,t� .•� , 7H Benjaa ri)Schiller ��.� CE 1259211/8/19 Approved U Date o� $ a0�0 FdApFEgSOP����° Inspection Report_9-1-12.doc FCO 100500 FEET 1"=50' NOTE: ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS.CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT MT - MONITORING TUBE SV - SEPTIC VENT DV - DIVERTER VALVE TH - HISTORIC TEST HOLE CONTOUR INTERVAL - 5' LEGEND PERMIT # OSP181311 PID # 017-152-20 SEQUOIA ESTATES, BLOCK 2, LOT 6 A B 2CO1 41.3 DV 43.0 CO1 44.6 A B 2CO2 56.4 CO2 116.2 MT1 118.0 MT2 95.5 65.0 67.5 69.0 68.0 107.3 109.5 109.0 Jan 23, 2020 3-BDRM HOME SHED SHED ALL E Y S P E C TR UM C I RC L E 10' UTILITY EASEMENT 10' UTILITY EASEMENT EXISTING WELL TRENCH CONSTRUCTED IN 1983. LOCATION INDICATED BY OWNER DURING CONSTRUCTION EXISTING ABSORPTION TRENCH NEW 66' LONG X 5' WIDE X 3' EFFECTIVE DEPTH ABSORPTION TRENCH.820815810CO1 CO3 CO2 2CO2 MT1 MT2 FD EXISTING 1,250 GALLON SEPTIC TANK TH 2002 EXISTING WELL EXISTING WELL RADIUS 2CO1 CO3 97.7111.2 TH 1982 PROFILE AS-BUILT (NO SCALE) 66' DRAINFIELD ROCKMT1 TH-2002SPURKLANDNO GROUNDWATER 10/25/02 77.8 80.8 CO2CO370.3 77.8 80.8 85.3 FINISH/ORIGINAL GRADE PERMIT # OSP181311 PID # 017-152-20 SEQUOIA ESTATES B2 L6 MT2Apr 03, 2019 January 23, 2020 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 1/23/20 Subject: Sequoia Estates, Block 2, Lot 6 – 6720 Spectrum Circle Test hole justification Dear On-Site Services Engineer: The septic system on the subject lot was installed in September of last year. The exact location of the trench was shifted during construction to accommodate conditions in the field. In the end, the trench was found to have been built outside the radii of the historical test holes used for the design. The trench was designed to a perk rate of 12 min/in, and a bottom of trench 7’ below grade. During the construction of the trench, we found soils consistent with the historical test holes along the entire length of the trench. In addition, we looked at test hole logs for surrounding properties and found that this type of soil is common in the area. The following table shows the property, the perk rates found, depth of hole, and groundwater readings: Property Depth Groundwater Perk Sequoia Estates Lot 4, TH1 9’ None 5.2 min/in Sequoia Estates Lot 4, TH 1986 15’ None 12.87 min/in Sequoia Estates Lot 5, TH 1986 18’ None 12.5 min/in Sequoia Estates Lot 7, TH 1983 16’ None 3.1 min/in Sequoia Estates Lot 8, TH 1986 14’ None Visually rated @ 150 SF/BDRM These records indicate soil depths, conditions, and groundwater levels acceptable to our design. We would like to request our observations during construction and these test hole records be accepted in lieu of digging a new hole for this permit. Sincerely, Benjamin Schiller, PE OF A 49 TH Y SHANE A. HOLT I&,LS-6914 'Ofession3� Ls ASBUILTSURVEY 1" =40' NO CORNERS SET THIS DATE I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY OF THE FOLLOWING DESCRIBED PROPERTY LOT 6, BLOCK 2, SEQUOIA ESTATES ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN 7HEINFORM477ONHEREONISFOR7-HEUSEOFLENDINGINSTITUTIONSSPECIFICALLYTOSHOWANY THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS CONFLICTSBEYWEENEXISTING STRUCTURESAND PLATTED I OTLWESAND/OR EASEMENTS,AND IS NOTTO BE USED FORPOSITIONINGADDITIONAL STRUCTURES, IMPROVEMENTS, ORFENCELINES. EXIST OTHER THAN NOTED. EASEMEN750FRECORD, OTHER THAN THOSEAPPEARINGONTHERECORDPLAT,ARENOTSHOWN DATED AT ANCHORAGE ALASKA THIS 24TH DAY OF HEREON (UNLESS INDICA TED) NOTE' FENCELINES THATMAYAPPE41? ON THISDRA WINGARENOTTO BE USED TO DETERMNE JANUARY , 2020 PROPERTYLINES OR POSI7IONADD?IONAL IMPROVEMEN75. ANYPA VINGSHOWNHEREONMA YBEAPPROXIMATEDUE TO EXCESSIVESNOWAND/OR ICE HOLT LAND SURVEYING 9309 GROVER DRIVE ANCHORAGE,AK 99507 A,; 19 FR 9119 -Al' l 345-5513 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP181311 Work Type: Septic Upgrade Tax Code Number: 01715220000 Site Legal Address: SEQUOIA ESTATES BLK 2 LT 6 G:2939 Site Mailing Address: 6720 SPECTRUM CIR, Anchorage Owner: KOPP CARL H Design Engineer: FORGE ENGINEERING This permit is for the construction of: Q Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date Lot Size in Sq Ft: Total Bedrooms: ,»rnt J ~ r. I)cpartmcnt 9/13/2018 9/13/2019 50440 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing CO '2"4 1 Received By: Issued By: qP/10 Ghangea " ren Ues�gn. Date: 3 Date: �2 Cl MUNICIPALITY OF : , • • io fi. , 61304) Community Development Department �']` SSP — Phone: 907-343-7904 Development Services Division ti Fax: 907-343-7997 On-Site Water & Wastewater Program ats• �Ac, 01 . 8L�' ON-SITE SEWERNVELL PERMI • 7. = CATION Parcel I.D. 017-152-20 Property owner(s) Carl H. Kopp Day phone 244-1632 Mailing address 6720 Spectrum Circle Anchorage, AK 99516 Site address Same Legal description (Sub'd., Block & Lot) Sequoia Estates, Block 2, Lot 6 Legal description (Township, Range & Section) Lot Size 50,440 Sq. Ft. Number of Bedrooms Three (3) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (2]all that apply) Absorption Field [X] Initial I I Single Family (SF) [X] Septic Tank I I Upgrade I Xi (w/wo ADU) Duplex (D) n Holding Tank I I Renewal n Multiple Dwellings Privy n (SF and/or D) Private Well I I Water Storage [1 THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. 741_41_1_,C mac? (Signature of property owner or authorized agent) Permit/Rush Fees: 569 Waiver Fees: Date of Payment: q(9-/(2 Date of Payment: Receipt Number: Cj 116 D Receipt Number: Permit No. US P 1 (,31 I Waiver No. Permit App__-:•::_.,c; a ' GE wENGINEERING PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) September 12,2018 MOA Development Services Dept, On-Site Water& Wastewater Program 4700 Elmore Rd Anchorage,AK 99507 Subject: Sequoia Estates, Block 2, Lot 6—6720 Spectrum Circle Septic System Design Dear On-Site Services Engineer: The septic system on the subject lot in in good condition and operating as originally designed. The owner of the property would like to construct two alternate absorption trenches in the event of failure of the primary system. We are submitting this permit application for the construction of two new absorption trenches for possible future use. The attached site plan identifies the location of the home and the proposed absorption trench locations. No conflicts exist between these proposed locations and any other well or septic system on this lot or adjacent lots. The ground surface on the lot slopes toward the west. There are no slopes greater than 25% within 50 feet downslope of either of the absorption trenches. Drainage arrows are shown on the site plan showing the grade and direction of flow. Storm water drainage will not impact this septic system. The new trenches will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new trenches will be a minimum of 100' from all wells and surface water, and more than 5' away from the septic tank. The trenches will be constructed a minimum of 6' or twice the effective depth from sidewall to sidewall. Please refer to the attached test hole log and plan and profile sheets for the septic design. If this design is followed,there will be no adverse impacts to adjacent properties. Sincerely, CpF A + lam'-cx—�7 P S ! Michael E. Anderson, PE �*�49 TH �.�i- �l Michael E.Anderson . F • 4381-E • (k,/r r1hf•,9/12/18,.• ��'\� l>1``�PROFESS Y '`.. ESTATES, BLOCK 2, SEQUOIA LOT 6 co i ft EXISTING WELL \ RADIUS / / / 10' UTILITY EASEMENT\ \ \ /DEMMOLIN ESTATES / LOT 5 L7T 6 10' UTfLITYYA�SEMENTLOT 6 ` EXISTING WELL - \ EXISTING 1,25 XISTIN�C*ABS TION \/ \ TAL ON SEPTIC \ VK TRH \Fvp 3-BDRM HOMEiCj L / r --j` p cO co MT o FD HED HE ria \L MT M1' `Cp TRENCH CONST UCTED IN MT pp 1983. EXACT L ATION AND STATUS UNKN IN. \ 66' LONG X 'WIDE X 3' \ ® \ \ \E FECTIVE DE H ABSORPTION \ \ \ \ T NCHES. ' EXISTING WEL) 111 \ \\\ \ LOT \ \'ROTE: i ` 7 ABSORPTION TRENCHES MUST BE U OR TWICE Al,=FFECTIVE 1/ DEPTIN FFROVNSIDEWALL TO SIDEWALL. IMPISH \ \ NOTE: \ \ NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE LEGEND ..... �,`m � PROPOSED SEPTIC SYSTEM CO - CLEANOUT ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS ZCO -DOUBLE CLEANOUT °°• �° " PROPERTY ARE SHOWN, NO CONFLICTS WITH WELLS OR SEPTIC FCO -FOUNDATION CLEANOUT 9 n Fz'" SYSTEMS. MT -MONITORING TUBE f ma .; r,FaDERsp 0 50 100 SV - SEPTIC VENT FD - FLOW DIVERTER VALVE FEETCr<, 9 «q,« •' <G 1' —50' TH -HISTORIC TEST HOLE 620-18 CONTOUR INTERVAL - 5' ����|/��� �J�- ���T�N1 ���/�U|���R8��J����' ----'--'''''`~'~~'`~~`�/�'.�_m/.^^_=�`/.��_.,.�_.~^~�. 450 GPD PEAK FLOW f/VNDETRENCH SYSTEM PERK RATE: 12 K8|NUN EXISTING 1.25O-GALSEPTIC TANK APPLICATION RATE: .8 GPD/SF 45OGPD /.8GPD/SF /5'VN[}E° 58RED.FACTOR=65.25LFTRENCHRE{]U/RED(66LF8PEC|F|ED) BOTTOM DFTRENCH: 7'BELOVVGRADE FLOW LINE ELEVATION: 4'BELOVVGRADE TOP OFTRENCH: .5'ABOVEGRADE = 5' RATED PVC (HOLES DOWN) TYPICAL WIDE TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TDDRAIN AWAY 2 PROVIDE 3y[}FCOVER OVER TRENCHES AND 4'OVERSEPTIC TANK, 0R2' WITH 2'(}FINSULATION 3. CHECK GROUNDWATER ATTIME OFCONSTRUCTION. |FLEVEL iSHIGHER9-5-18 THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY RGE """'=`"'"" DF �aCHAELcANDERSON 4/ ss,.y .... / 'O• p6 s.1, / „,,.,. ,...p 4., 6 ,5, Jr, 4:t., .6., ,, ‘ y,/' „„ . .. ,,,,:., /... ..„, ,, WELL / �d / // / 'b DECK \\; \ _..-..-_.._. _ /' 0 ®` SPNpl7 / \a�� SINGLE F ORIV�JAY..,- // ��\ FRgA�E H I SE - --- ----- _ 0, / ,.`, �-::- __,. 708 / .‘,.;\2,./0 HE� \ n • a `\ N a p `, S. y `` AS BUILT SURVEY 1 = 30 ' NO CORNERS SET THIS DATE o tib h I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY �d OF THE FOLLOWING DESCRIBED PROPERTY • • �,� .'i. eiscK 2. SEOUJIA ESTATES Si.B" i FLAT 82 3:: e�p'O�OQQO OF A t"%� VISIBLEANCHORAGIMPRODVEMENTS SITUATED THEREON ARDS WITHINT HE Op � _����S�QO THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS p�; 49 TH %\\ �*�O O DAY OF . THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY EXIST OTHER THAN NOTED. Q : CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS; AND IS DATED AT ANCHORAGE0,AALASKA THIS Q „'w/?(✓E G NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES. A; ,S? o EASEMENTS OF RECORD, OTHER THAN THOSE APPEARING ON THE RECORD PLAT , ARE NOT SHOWN ��� 'O 18 QSHANE A.HOLT O HEREONO ( UNLESS INTIATTED) HOLT LAND SURVEYING 04 P� LS-69. 5�p� NOTE: FENCELINES THAT MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE 9309 GROVER DRIVE 4 PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS. ANCHORAGE,AK 99507 Q4op ac o ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE. -' 345-5513 o7ess. . t..zo ;5. FB 1d �DOOOoo �` Municipality of Anchorage Development Services Department Building Safety Division • • • . On -Site Water and Wastewater Program, 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 99519.6650 Page of www.ci.anchorage.ak.us (907) 343.7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: n o y5 PID Number. 171— 15 — O Name CAV.L lob P P Wastewater System: ❑ New Upgrade Adcress &'7;_o SPI Cre o m G ABSORPTION FIELD Phone Number of Bedrooms, Deep Trench D Shallow Trench (3 Bed C] Mound ❑ Other LEGAL DESCRIPTION Soil Rating, 010 O, Depth from ongmal grade , ,p,2 Ft Block Subdmsom Depth to p" bottom from original orade Gravel depth beneath Pipe. �L•ot /� L b 1 Y A �J� FI. FI Township Range Secbom F4 added above original grade Gravel Length Ft. 2�// (7 O Ft. Well: ❑ New ❑ Upgrade Gravel width Number of toes ( Distance between lines �—• 4p,Ft. Ft C lissiFcabon (Private. A B. C). Total Depth: Cased to: Total absorption area. �r�Pipe Material ,6 Ft. Ft U Ft' p r 3 Onger �s Date Drilled: Static Water Level: Installer. r - Date Inst") 1111 I Ft. L D Z►• Veld Pump Set at: Casi g Neghl Above Ground; TANK GPM FI. FL SEPARATION DISTANCES KSeptic (:]Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption Lift Holding PublictPrivate Manulaaurer. Capacity From Tank Field Station Tank Sewer Line Q (,P -r ' Gal Wet 110 tic _ /_� .,/� _ Material. �+ _ s t Ek L Number cf Coommcarore•+u :2.. Surace Water T,, H1.p LIFT STATION Size ManUl•CIWan; Lot Line C?p �l �p Gal Fourtla•�on O ~ 'Pump on' kvat at -Pump o level at Ngh water alarm at n m in 010 aJ � T Pump Make d Model Ele .ncal Inspections per!ormetl by Curtain Drain � b Remarks BENCH MARK Location and Descnpton: Assumed &aveaon Y Ll. 1r'r •C Jam^ /�1..+ dj'Ft 10� Engineer's Stamp %�; r• �•�ea a1 Inspections performed by: Dates: 1" It L 2 0 'L R�4� �nsr}s P1D1�a"d+wq"l y�I ti Moe.••• nd fl 2 O 'I Ma •NN Development Services Department Approval I�3 iHt6b �� ,or Reviewed and approved by: Date: \���.j.'•. :'co� tar, t:an ti ��•ee..e.•••'• i `�` `V �4 1p - 1 i /• llel► � ' � � � 100 i � BENCH DOT= ,04AD 66, 0042 AE 60, BE 67 0 00e,\ \ \ STAAVAPD 3-6EQYPOAI/ SY51EY \ 1250 " -WFT LOWW TANK.01,�T \ \ \ 9 fT &W 1 Y ��� ................ f \ \ \ 5 ROCK 3 fT conR i•7J•''•••• .••• •• ♦♦j \ rte; 49th •••' ♦� \ ` 1 IN ..................... .....I \ \ \ ....... ••• 0.n•T13B SP ••� ♦ NO, CE -2225 V 25 0 50 75 10D 125 150 CALEt 1' = 50 FT. sY'• well \ \ TOBBfN SPURKLAND .. _. LOT 6 B OCK 2 SEQUOIA ESTATES SEPTIC SYSTEM AS BUILT 203 W 15TH. AV£NU ' CARL KOPP DATE: NOV 16, 2002 ANCH. AK. 99501 6720 SPECTRUM CIRCLE SHEET- 215 GRID. 2939 907 279-3916 PERMIT #SW020453 PID # 171-152-20 SE002062,OWG O O O 0 1250 gal Septic tank c a, m 3 A Standard Trench, 2' W1de 60' Long 9' Deep 50' Sewer rock 3' Cover14, AV AV .•• 49th NO SCALE Sll t 6.0 ft of Septic Rock Effective Monitor — NO SCALE IVN SPURKLAND No. CE -2225 1250 GAL SEPTIC TANK a 3 TUBBEN SPURKLAND P.E. LOT 6 BLOCK 2 SEQUOIA ESTATES SEPTIC SYSTEM SCHEMATIC 203 W15th Ave Anchorage Ak 99501 CARL KOPP DATE NOV. 16, 2002 67M SP£CMW CXCIE SHEET, 3/3 GRID, 2939 PERW I SWO20453 PARCEL lD j 171-152-20 SE002063.DWG MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water& Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 //12./02 i S / J.' 0067. /S. -f ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW020453 Legal Description: SEQUOIA ESTATES BLK 2 LT 6 Design Engineer. 0007 Tobben Spurkland, PE Owner Name: Carl Kopp Owner Address: 6720 SPECTRUM CIRCLE ANCHORAGE. AK 99516-3726 Date Issued: Nov 08, 2002 Expiration Date: Nov 08, 2003 Parcel ID: 017-152-20 Site Address: 006720 SPECTRUM CIR Lot Size: 50440 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of. ❑✓ Disposal Field E✓ Septic Tank Holding Tank Privy E] Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by catling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: Date: 8k Municipality of Anchorage !� Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.enchorage.ak.us (907) 343-7904 ON-SITE SEWERIWELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parce! I.D. 01-7 — 16;_ — A D Permit Number SW020¢5T-3 Property owner(s) eAt aL- 1Ln P -P Day phone Mailing address (1) 67PLO SEECIPIVM G112 Cl;t= Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) WI !o . 5K 2 S t Q U Of Q i riz� s-rArii- Legal description (Section, Township & Range) Lo' Size 6-0gl-to Acres Sq.F THIS APPLICATION IS FOR: Number of Bedrooms 3 Sewer Only ❑ Well Only ❑ Sewer and Well Water Storage Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi' ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made fcr Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees:4 �Waiver Fees: Date c` Payment: 0/2,?/ OL Date of Payment: Receipt Number: Receipt Number: (Rev. 12100) T.SPURKLAND P.E. 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 6 BLOCK 2 SEQUOIA ESTATE CARL KOPP Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street Anchorage, Alaska 99519-6650 October 23, 2002 We are submitting an application for the upgrade of the septic system for this lot. The submittal consists of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the septic system is subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed. The septic system design is based on the following: No Ground Water or Impervious Layer to 15 ft. Use Standard Trench Soil Rating. From Testhole 10/18/02 12 min/in = 0.8 gal per sq.ft/day No. of Bedrooms 3 Required Area per Bedroom: 15010.8 = 187.5sq.ft. Total area required: 187.5 x 3 = 562 sqft Testhole depth IS feet Bottom Rock At 9 feet Top Rock At 3 feet Rock Depth 6 feet Minimum Trench Length 562 / 12 = 47 R Use 50 ft SYSTEM CONFIGURATION STANDARD TRENCH TOTAL LENGTH 50 FT TOTAL WIDTH 2 FT TOTAL DEPTH 9 FT ROCK DEPTH 6 FT COVER 3 FT SEPTICTANK 1000 GAL The installation of this septic system will not prevent wells and septic systems from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. \ „ 10, / \ \ ' 1Pell � CIRCLE 50 0 50 100 150 RX 2w as SCALE, 1' = 100 FT. TOGSEN SPURKLAND P.E. LOT 6 BLOCK 2 SEQUOIA ESTATES SEPTIC SYSTEM DESIGN 203 W 15TH. AVENUE CARLKOPP DATE: OCT. 23, 2002 (NCH. AK. 99501 907 279-3916 6720 SPECTRUM CIRCLE SHEET 1/3 GRID: 2939 PERMIT #SV02OXXX PID # 171-152-20 seg02061.dwg Well -- , / �- , \ \ STANDARD 3-dOEAQAGI/ STSIFY \ M GIC SOW TANK \ \ STANDARD MAWI� I ♦���al�i�•• \ SD a Lax j lL \ \ .91T" ♦• ......•�••. •1. \ \ 3 IT CDYER i �•'�• �j \ \ rOLWDITM CLAN OUT "q r 49th •••••• '} \ \ DM" VALVE To OLD MACH w,.••.;; • •.•,•„,.,•,.••••• „ •,,, i \ \ / .••TUB SPURILAND ••� �. NO. CE -2225 ' .•4 \ _• •_ Y \ CJ D SD 75 LAD 125 150 rti CALE7 1' = 50 FT. WIRMN W-UNAL M11 LOT 6\BLOCK 2 SEQUOL4 ESTATES SEPTIC SYSTEM DESIGN 203 W AK. 9950101VENUE-367'TE.• C(RLKOPP DAOCT. 23, 2002 (NCH. (K. 907 279-3916 11 6720 SPECTRUM CIRCLE SHEET • 213 GRID: 2939 PERMIT #SV02OXXX PID # 171-152-20 SE0020620W6 Standard Trench: 2' Wide 60' Long 9' Beep 6.0' Sewer rock 3' Cover Sll t 6.0 ft of Effective FO - 0 0 0 1000 gal Septic tank a � V 3 Q 49th:;: 1••�No. CE-2-22.5.... NO SCALE 4f��SS U O a 3 nu Jlif1LL 203TUBBEN W1 SPURKLAND P.E. LOT 6 BLOCK 2 SEQUOIA ESTATES SEPTIC SYSTEM SCHEMATIC An orag Ave CARL KOPP DATE, OCT 24, 2002 M-291Ae Ak 9 11 9501 6710 SKURMW CSE SHEET, 3 3 GRIDi 2939 PERW SW020XXX PARCEL ID # 171-152-20 SE002063.DWG Municipality of Anchorage A Development Services Department Building Sa!ety Division R O yr On -Site Water and Wastewater Program 4700 South Bragaw SL P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.anchcrace.ak.us , (907) 343-79N f S Soils Log - Percolation Test `I Performed For:lid DalePer!ormed: Legal Description: L4 i oe Township, Range, Section: Depth be Aw s L 1 oa ��.� 2- 4- 5- 6- 7- 10- 12- 13- 14- 15- 16-' 17- i S- Ia 5-6-7-10- 12- 13- 14- 15- 16- 17- 15- 19 COd.It, IENTS 8a4H_6C N e 6oTTa M or Nate— YrasGROUND WATER 1 ENV NTERcD? N1 Net Drcp S IF YES. AT WHAT DEPTH? L 0 Depth to Water After P Monitoring? h%'E Da'e: "CIA151g, Z s to PERCCLATIDPIRATE I jL_(rmtesir0) FzKR;t-Q'tE TEST RU`I EET`NEVI _(F, AND _ �% FT PERFOR` ED BY: d S 1 CEKTIFY THAT THIS TEST V`:AS PERFOR?,IED IN ACCORDANCE_ WITH ALL STATE AND MUM CIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 1 Q /.Z3/0 Z Gross Time Net Time Death to Water Net Drcp pDzte D I7 '/ I I PERCCLATIDPIRATE I jL_(rmtesir0) FzKR;t-Q'tE TEST RU`I EET`NEVI _(F, AND _ �% FT PERFOR` ED BY: d S 1 CEKTIFY THAT THIS TEST V`:AS PERFOR?,IED IN ACCORDANCE_ WITH ALL STATE AND MUM CIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 1 Q /.Z3/0 Z Municipality ®f Anchorage K Department of Health and Human Services Tom Fink, 825 "L" Street Mayor P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 June 11, 1993 Federal National 135 North Los Poblos Avenue Pasadina, California 91101-1707 Subject: Lot 6 Block 2 Sequoia Estates Subdivision Permit #SW920077, PID #017-152-20 The subject permit, issued May 8, 1992 by this office for a single family well and/or on-site wastewater system, has expired as of May 8, 1993. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as -built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. When applying for a new permit,'the fees are: $200.00 for an on-site wastewater permit; $75.00 for a well permit and $275.00 for a combined on-site wastewater and well permit. A If you have any questions, please call this office at 343-4744. Sincerely, 2�� 1 r 1) `)� Daniel J. Roth Acting Program Manager On-site Services cc: Tobben Spurkland, P.E. cdrl n, xopp 6720 Spectrum Circle 99516 PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW920077 DATE ISSUED: 5/08/92 DESIGN ENGINEER:TOBBEN SPURKLAND, P.E. EXPIRATION DATE: 5/08/93 OWNER NAME:FEDERAL NATIONAL OWNER ADDRESS:135 N LOS POBLOS AVE. PASADINA, CALIFORNIA 91101-1707 PARCEL ID:01715220 LEGAL DESCRIPTION: SEQUOIA ESTATES BLK 2 LT 6 LOT SIZE: 50440 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ISSUED BY• DATE: za��' '�. DATE: S�-�2 . -y-" F; 10»U Hoc RAC R.. OR ��~ 6751N.0IOND80D. ANCHORAGE, ALASKA99502^3Y04 (Y07)248~5095 Municipality of Anchorage April 29� 1992 Division of Environmental Health Department of Health and Social Services 820 I Street Anchorage, Alaska 99501 Subject: Permit for Septic System Upgrade Lot 6, Block 2 Sequoia Estate Septic Tank Relocation During an Health Authority Inspection it was discovered that the septic tank on subject property was 80 feet� more or less distant from the well. The well is 105 feet from the absorption field on lot 5. By rising the line from the foundation to minimal grade J.t should be possible to reinstall the septic tank at the proper distance from the well and reconnect the tank to the drainfield^ Yours Tobb�n Spurkla�d P.E. / ` i i O R 6 00 i i� � Wel( i /Top, ofeeeclv 00.00 /. \ �In-vtoll Clean ut 100 Ground 97,1 \ \ � Exist. Tan \ \ \ New tank Ground. 975 \ \ Tank Bottom 876 \ \ \ Sump Bottom 8p, i \ \ \ / / -�- Well I \ \ \ \ � 25 0 25 50 75 100 125 150 SCALE. 1' = 50 FT, TOBBEN SPURKLAND P.E. I ILOT 6 BLOCK 2 SEQUOIA ESTATE SEPTIC SYSTEM DESIGN eW 15TAVENUE 12os 03ANCH, AK. 99501 SECTION ?6 TIA DATE, APRIL 28, 1992 ,,,,,lFANNIE Mn SHEET. 1/1 GRID 29. , \ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264.4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAMEI �.,( _ A� World New World �1��..� jC P�t�a/�' �w�.'/" '7 ANEW UPGRADE MAILING ADDRESS LEGAL DESCRIPTION BIK 2 Q t _e LOCATIU NO. OF BEDROOMS 1rY l v Y DISTANCE TO: Well ►`i & 'in Absorption a ea 0 Dwelling Ir1of If f PERMI N_O. :'S ` Manufacturer erial No. of compartments o~. Q w r _ I"' 1� - j yin gallons Liq. capacity IF HOMEMADE: Inside length Width Liquid depth DISTANCE TO: Well ` Dwelling PERMIT NO. = z F Manufacturer Material Liquid capacity in gallons w= DISTANCE TO: Well-%� Found a ion, Neafboltime PERMIT Ng. i J� I J LL Z P Z w No. of li es Length oLeach line - 7 Total length of lines Trench width 6 inches Distance be n lines HTop finish Material beneath tile Total effecti a absorption area of til to grade -/ OV p inches Length Width Depth PERMIT NO. Lu 0 Q F- Type of crib Crib diameter Crib depth Total effective absorption area wa W Well Building foundation Nearest lot line DISTANCE TO: J Class Depth Driller Distance to lot line PERMIT NO. J Lu � DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER - PIPE MATERIALS )ow +/ C� _ SOIL TEST RATING _ /�) INSTALLER World orldl L ne 4' li' . i r 1P REMARKS , c� V' i APPROVED DATE LEGAL yy--,� f � 0) l r / 4J V Jamal 4' %%�%' Ser ®:� ✓'-"� / 2`0)l s� 72-013 (Rev. 3/78) DEPARTMENT Nim . HEALTH AND ENVIRONMENTAL MENTAL ` iTECT IONd 25 STREET, ANCHORAGE, AK:. AL 264-4720 &-I E= 0 E* F-1 r-•1 E's a=e PA — I -F E:' ' E= E.R.@ E_ F.F=:'[-= P' Pl I _F PERMIT NO. 82:021:2251 ) APPLICAN•dT NEW WORLD LAND CO. P.0. BOX ii -13:14 345-27:854 LOCATION a LEGAL LCAT r, BLK SEQUOIA �� Ad�0• LOT SIZE 999999 SQUARE FEET TYPE OF SOIL ABSORPTION SYSTEM IS.: DRAINdFIELD MAXIMUM NUMBER OF BEDROOMS = 3 SOIL RATING (SQ FT/BR)= 125 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: 1 u r-= F _E""- _ 15v_ �- 15=--- E �� s=� ° E= E- C-° = E=° _F"= THE LENGTH DIMENSION IS THE LENGTH :INd FEET) OF THE TRENCH OR DRAINdFIELD. THE DEPTH OF A TRENCH OR PIT I_ THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION iN-d IN•d FEET?: -E- F--_ E E •.E eZ E ---E 14=o -r" I = !ffu _ THE GRAVEL DEPTH IS THE MINdIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL F'IF'E AN•dC: THE BOTTOM OF THE EXCAVATION (IN FEET:. ER_ F= e_.A U I 1=_ F= ED, 1_ E=" -F 16=_ _7'_ E_� E"-.1 IK _=e I = F == :JL C-1 e=1 ID eEe FB 1._ E_ a=e PERMIT APPLICANT HAS. THE RESPONSIBILITY TO INdFORfT TH I _ DEPARTMENT DURING THE INSTALLATION INd'_PECTIONdS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. - — — -1- L4 C-1 °-_ „2 > I F" O= C -' -r I e=e 1"-4 H F --"F= F-: K= CA U I F_ W= -° — — — BACKFILLINdG � �F ANY SYSTEM WITHOUT FINdAL INdSPECTIONd AND F=1F'F'ROVAL BIT THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINdIN'IUM DISTANCE BETWEEN A WELL. AND ANY ON-SITE SEWAGE DISPOSAL. SYSTEM IS 100 FEET FOR H PRI`,+HTE WELL OR 150 Ti i 200 FEET FROM H PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC: WELL. MINIMUM DISTAN•dC:E FROM H PRIVATE WELL TO A PRIVATE SEWER LINE I S 25 FEET AND TO H COMMUNITY :SEWER LINE IS 75 FEET. WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO i THE DEPARTMENT WITHIN _ 0 DAYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS, ARE AVAILABLE TO INSURE PROPER INSTALLATION. E=" I= Ems° l-1 I -F- FEE X1=" I FR Ir E-° I e=- E 1-1 E= F= -1 - - "-==u I CERTIFY THAT 1: I AN FAMILIAR WITH THE REQUIREMENdTS. FOR ONd-S•ITE SEWERS, AND WELLS AS. SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. . I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.. 3: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS. REMODELED TO INCLUDE MORE THAN = BEDROOMS. SE GNdED : __ A�'PL I i� ANdJ� NdEF bdORLG LANdD C:O. ISSUE[., ------V"N. 0 PERFORMED LEGAL DESCRIPTI DEPTH (FEET) 1 2 3 4' ` 0 0 U 5 , �• 6 0 7 Ov U 9 10- 11 0 11 L Gs ° 12 /. Q L 13 14 / 15 / 16 17 18- 19- 20 8 19 20 B.; COMMENTS I vD /L X.)�Q '� �'y /f „'{. � �, _ 5 K SOILS LOG UNICIPALITY OF ANCHORAGEttqq�I )EPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 1 1 PERCOLATION TEST 825 L. Street, Anchorage, Alaska 99501 264-4720 _ SOILS LOG — PERCOLATION TEST ' JEW WORI0 "/49 rn- DATE PERFORM 0fe(/I (V/US ,SANDY GRAV9L OW SLLTY SAHDY' GROVE ;M .-_S/LTT sAry®r. CLAY f5G Qf"J�4; Date Gross Time Net Time 3 Net Drop ," 714 /6 2- 19 oacQ cn; axPYi6e uC5b46eQm�,.•, v e± Earl R. Qarnard ],^, 754E � PERCOLATION RATE /�rYGy -(minutes/inch) TEST RUN BETWEEN FT AND FT SLOPE SIT T 'AA-LL(C'c Cg�� WAS GROUND WATER/yo L ENCOUNTERED? 0 P IF YES, AT WHAT DEPTH? 7 Reading Date Gross Time Net Time Depth to Water Net Drop 714 /6 2- 1 35PM q %" 9/4/BZ 12.40 Pry 5- 1'1/1y 5 PERFORMED BY: JL n � j CERTIFIED BY: 72-008 (6/79) TE:44�9-2-