Loading...
HomeMy WebLinkAboutSERTICH TR BOnsite File Sertich Tract B #014-241-20 Municipality of Anchorage On -Site Water and Wastewater Program - (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: SW960054 PID Number: 014-241-20 Page 1 of 1 Dwelling: ❑ Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New ❑ Upgrade Name: Pat Crabb JA 4115 East 88th Ave, Anch., AK Phone Number of Bedrooms 907-227-5066/907-227-4427 3 LEGAL DESCRIPTION Subdivision Block Lot Sertich Subd, Tract B Range Section SEPARATION DISTANCES To From Septic Tank Absorption Field Holding Lilt Station Tank Sewer Line Well 100+' 100+' i NA NA 25+' Surface water 100+' 100+' NA NA Lot Line 10+' 10+' NA NA NA Foundation 5+' 10+' NA NA Curtain Drain U K UK I NA NA Remarks *3034 solid **3034 perforated I Installer Inspector Inspection dates: Owner (Pat Crabb) F Kenley BSORPTION FIELD ❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound ❑ Other I Rating Total depth from original grade 0.8 GPD/SF T1=10.9'; T2=9.9' Ft. pth to pipe invert from original grade Gravel depth beneath pipe T1=2.8'; T2=2.6' Ft. T1=8.1; T2=7.1 Ft. added above original grade Gravel length T1=5.0'; T2=5.0' Ft. 2 @ 42'=84' Ft. avel width Beds: Number of Lines Distance between lines 2.5 Ft. NA NA FtJFt. tal absorption area Number of trenches Dist. between trenche 1,276 Fe 2 13' TANK 0 Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity Anchorage Tank 1 1,250 Material Number of compartments Steel 2 LIFT STATION Manufacturer lCapacity NA on level at 1pump off level at High water alarm at in.1 in.1 in. make and model Electrical Inspections performed by PIPE MATERIAL House to tank Tank to drainfield Drainfield ** CO/MT */*� BENCH MARK (Assumed elevation) 100.00 ft 1" 6/22/96 2"d 9/27/96 Location and description 3'd 10/24/97 4`h Garage slab finish floor COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL E�g�rt�e��S�mp itional Approval: Approved �' Ai Approved .,� N-UJ-01, Insoection Renort Date Date 6 �' foo OF AC,�s��� ,a, C � 49 TTH ..I .. . D lasT. Kenley NOTE EC'H THE FRI-IAR1AND 'HE StCuT10AR` IRENC�ES A E IN6IAELED. __ANDS FOR CU.h.+-Cil1. Y.1, STANDS FOR MONITOR IU? r ABSORPTION SYSTEM PLAN (ASBUILT) EXISTING �• _ DESCRIPTION DOUBLE CLExN CUT -1 — SEPTIC TEMS�9 ON ADJACENTTPRO SYSYSIE 14.6' 7'' ! -- 200' MIN. FROM PROPOSED SYSTEM. -- ? —t- !h „LE-- CUL- v 13.6' I I W - --' lti.i'. � 37. $' — --j Tr. A I I i 0' g6 - i 1 i 24.0' _3_t 7 -----1.250 GALLON STEEL SEPTIC TANK I 73_4' ��Flf R TRENCH C.0-2 i 65 v i v 81 A, -- OND Pv !KNCH 1 6 _ 6F.4'—I 145.00' SO'59'E : I ' F6 0 "1 3 10 FT. UTILITY EASEMENT, S CONDARf IRENCH C. t I 727 Q7 �— 80* Ci `=38• (3) BOW. - . w 38'I RESIDENCE..... �. _ `. I ' t ��. TPji V Q O 38 LU B'B' I TPk2.` o f E ,2' -PRIMARY TRENCH ----"\1 �Jt O . I t at _ TP#3 t 1 scOry �o • 'q�0� I �8_. 5 t \ S I F Tr. B 43.562 SQ, FT. 1 � •'+ LOO ACRES ! I • y> ' I , �. �' ' ' 297.08S89.59E li I -- -- - _ r E. EIGHTY-EIGHT AVENUE r� y \ NOTE EC'H THE FRI-IAR1AND 'HE StCuT10AR` IRENC�ES A E IN6IAELED. __ANDS FOR CU.h.+-Cil1. Y.1, STANDS FOR MONITOR IU? r ABSORPTION SYSTEM PLAN (ASBUILT) SWING TIES (ASBUILT) ITEM ( 7 _ DESCRIPTION DOUBLE CLExN CUT -1 — A B C ID E _� 15.11' TAA: 14.6' 7'' ! -- �— -- ? —t- !h „LE-- CUL- v 13.6' I I i LiiUoLi_ CLEAh1 CUT -2 - --' lti.i'. � 37. $' — --j 5 B L PUIJ rlt EY IER ✓ --� r� — i 0' g6 PRIMARY TRENCH C.0 � _ i 24.0' _3_t 7 - PRIMARY TR ICM.-I. I 73_4' ��Flf R TRENCH C.0-2 65 v i v 81 A, -- OND Pv !KNCH 1 6 _ 6F.4'—I I SE COr10: ? t Tr INCH t -+ F6 0 "1 3 S CONDARf IRENCH C. t I 727 Q7 �— DOUGLAS T. KENLEY, P.E. Civil Engineer ASSUILT M E tFMhauw arch Pdmar, Alaska 80815 (907) 748-107! Pet Crabb T(C t e, SP(tle>; CU}, .I i,;+ISIC'1 -rssP.r, p. 18 R ER-. 41 I East 88th A.ve. urc , AK 2 : 1 -20 S0L),U ee 20 �z5 SF= 1 of JA OF• At'gs��a ® 49 TH ... .. .......... Dough Kenley �® FFG, CE -8176 i TANK SECTION (ASBUILT) DOUGLAS T. KENLEY, P.E. Civil Engineer 4808 E Nottlnhr dreb Pdrtwr, Almka 848/8 W 7461073 Pa rc t. c 'r TractSSC t'h Si 'is -_---- E 88t rcf 4K p U1� 24 —20 1 � 71 e .... _K i js :ems p t QC OF At ®®� ® .' 49 TH .. ,.......... p ASBUILT e . . • • Dougl8s i. Kenley CE -8176 S;,96005=9F�PROFESS\OOQ ®® SH 2 of z MONITOR TUBE — CAPPED PIPE IS PERFORATED IN SEWER ROCK, SOLID ABOVE. MT - 102. FROM SEPTIC TANK f 4' DIA. PERFORATED PIPE — LAID LEVEL WITH HOLES DOWN. SIDEWALL OF TRENCH 3/4• — 3' DIA. SEWER ROCK MT - 86.2' MT - 102.1' — — — — — --,— 'nLTER FABRIC BULL RUN DIVERTER VALVE , 94.9 CO -1-94.3' CO -1-94.6' CO -2-94.3' CD -2-94.3' Tu�rc MT - 87.2' _TEST HOLE BOTTOM ELEVATION = 801' GROUNDWADING ATER P ESEAY NY 1996 ESHOWED TTETDNO HOLE. NOTE: CONSTRUCTION NOTES AND MATERIALS ARE TYPICAL FOR BOTH TRENCHES. VERTICAL CONTROL = 100,00' GARAGE SLAB SEPTIC SYSTEM SECTION I NTS DOUGLAS T. KENLEY, P.E. Civil Engineer 9806 E.Ncrthrta CIRls • P.Wwe Alaska 99643 • (ROTI 745-1073 CtEN1 Pat Crabb LEC4L Tract B, Sertich Subdivision ADDRESS:P.I.D. NUMBER: 4115 East 88th Ave. Anch., AK 014-241 -20 DATE: 2/20/20 1CHECKED: 0TK DAWN: FK scA1.E: NTS JOB NuuBER: 97000 ASBUILT '— SW960054 SHEET 3 of 3 �` OF AtAs'1� .�, 'oCX001* TH Q` Douglas T. Kenley 6, • , CE -8176 .,4.q J' ' .Zr' 2^5. '�c� r PROFESS00 Engineer: Legal Description Parcel ID: Permit: Municipality of nc®rage On -Site Water and Wastewater Program P.O. Box 196550 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.mun i _orglortsite Review Comments CRABB PATRICK D & DEANNA H SERTICH TR B 01424120000 SW960054 WellSeptic Report Type: As Built Review t lleparIIIIcttt 1/28/2020 Completed By: R.Carroll The application has been reviewed and the following comments have been generated. These are to be satisfactorily addressed prior to MOA approval: 1. For trench 2 (T2), the "Depth to pipe invert from original grade" plus the "Gravel depth beneath pipe" doesn't equal "Total depth from original grade." Please address. 2. Please enter total absorption area on the inspection report form. 3. Please confirm swing tie distances "B" to points 6 through 11. 4. The west ends of the drainfields measure closer to 10 ft apart. A minimum 14 ft was required. Please address. 5. An as -built survey on file (dated April 29, 1998) has the well less than 100 ft from the septic tank. Please address. 6. Please note the groundwater level observed (i.e. dry) and date of monitoring on the section drawing. Responses to above comments by Douglas Kenley, P.E. on 2-20-2020: ..,y 9. Corrected. See revised drawings dated 2-20-2020. 2. Added. See revised drawings dated 2-20-2020. 3. Minor changes (02 feet max) were made to three swing ties. See revised drawing dated 2-20-2020. 4. The close proximity of the two trenches was an oversight during construction. One trench is primary and the other is secondary trench separated by a diverter valve. Only the primary trench has been operated since construction. The secondary trench will only be operated in the event the primary trench fails. Please advise if this is acceptable. 5. The distance between the well and the nearest cleanout on the tank is 903 feet. Accounting for the one foot distance between the end of the tank and the cleanout the separation between the well and tank is 902 feet minimum. The as -built survey must be in error or not to scale. 6. Date and status of groundwater in the test hole has been provided on the revised drawings dated 2-20-2020. End of Responses. I ictal Grilled - 120' Casing Length - 7-13' 0' 10' Silt aM wands —` -10'- 30'- Sands vtlith small gravel 3Q' - 35' - Silty find sand :35'- 73'- Silt with small gravel 73'- tf8'- Water with sands and grave 78'- Fj'3'- Sand and gravel, possible silt tense 7bc o e Unable to pull casing east this depth 100`- Sand and gravel 00'- 120'- Silt with small gravel Ron Qi lhlet Qresrden y9 Qenali,b i�Stteet07 V g Ya 8240 peter01,tsptasica 995 �y { �� pnchora9e' c 562 —3A2 2% 907 562'69 220 ichie o a1x.net CO 907 440 rp ,net denati0 iidriliinrJ•com wvrf�.de"a F 1P IT'D/• f'OTi -- 7"/� A --- o /O ' 617- /4- ESM 17— I .WELL D1C �A�$°ot D/< \ �> 1 TI �v h6'f 6i'e REPAP, m r-�rT• FY NAI, P v l�(-ALE- ►-t}o! EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED PLAT ARE NOT SHOWN HEREON. ° / c Z 97 a5, , E1,,w7w fi V a u..< � � r •.� ` p NO. 1323-5.," oZoe " ev r• VVy ° Lam» k••- �n •�•.oyi• oaw� .w :.• n �.l rod '/yalrtkra c `. +' n M1I{ s. oU O�OG Oart�•�y��i 4..7 C,�l 'T�fiEscicNt�'� ti qr' 01 I AVI:A/UC— �S6Uilf 1(e r.I RoTi 2 FMD, /SOA/ SOD FIVT2 M67,A . lN / e.W. c41r r I hereby certify that I have surveyed the following described property: 7—tC,4 G7" r Anchorage Recording Precinct, Alaska, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on prop- erty lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon: Dated atAnchorage, Alaska this���gq"day ofd r'R /,L 19_ FRED NVALATKA & ASSOCIATES Engineers and Surveyors 'ci ality ®f Anchorage Department of Health and Human Services 825 U' Street Rick Mystrom, P.O. Box 196650 Anchorage, Alaska 99519-6650 Mayor 343-4744 June 3, 1997 Patrick D & Deanna H Crabb 8051 Cranberry Street #5 Anchorage, Alaska 99502 4445 Subject: Tract B Sertich Subdivision Permit #SW960054, PID #014-241-20 The subject permit, issued April 22, 1996 by this office for a single family well and/or on-site wastewater system, has expired as of April 22, 1997. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as -built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. Sin e ely, W C V Jam s Cross, P.E. Pro 'ram Manager On-site Services ens_ Copy of Permit CC: Douglas T. Kenley, P.E. AMA Caff PAGE 1 OF 1 A, MUNICIPALITY OF ANCHORAGE nC�LS� DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 l- ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT nKl\ PERMIT NUMBER:SW960054 DESIGN ENGINEER:DOUGLAS T. KENLEY, P.E. OWNER NAME:CRABB PATRICK D & DEANNA H OWNER ADDRESS:8051 CRANBERRY #5 ANCHORAGE, AK. 99502 PARCEL ID:01424120 LEGAL DESCRIPTION: SERTICH TR B LOT SIZE: 43562 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: l DATE ISSUED: 4/22/96 EXPIRATION DATE: 4/22/97 /j L�D p Y1 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: TOTAL DEPTH OF TRENCH MUST NOT EXCEED 7.5FT. RECEIVED ISSUED BY B : G DATE: n vvv�GL�t�� DATE: �e%a�io✓1 C� ��enchl�s) -panl� / ad opproved 9/3197 Douglas T. Kenley. P.E. 9960 East Puffin Drive Palmer. Alaska 99645 (907) 746-1076 August 21, 1997 RECEIVED AUG 28 1997 Mr. James Cross Municipality of Anchorage Municipality of Anchorage Dept. Health & Human Services Health & Human Services On-site Services Re: On site well and wastewater disposal system permit #SW960054, issued April 22, 1996. Owner: Mr. Pat Crabb 8051 Cranberry #5 Anchorage, Alaska 99502 Legal: Tract B, Sertich Subdivision Anchorage, Alaska Dear Mr. Cross: On November 5, 1995, two test holes were dug to determine ground water, possible bedrock levels, and percolation results. No ground water was observed in either test hole after the seven-day waiting period. A septic system design was submitted to your office on April 1, 1996, which was reviewed by Mr. James Williams. A restriction was placed on the design stating that the total depth could be no more than 7.5' because Mr. Williams, in a subsequent inspection found ground water present in test hole #1. An inspection was made by my office after Mr. William's visit and no ground water was found, but it was noted that the monitor tube had a built-up of frost in the upper portion of the tube. On May 11, 1996, a third test hole was dug because the owner wanted to move the location of the proposed house. No ground water was detected on this location either. This monitor tube is still in place and can be measured for ground water. Three readings have been taken since August 15, 1997, and no water has been detected; therefore, I am requesting that your office review this new design and consider it for two 2' x 7' x 41' primary and secondary trenches with a Bull Run diverter valve installed. The septic tank and well were installed in July of 1996. The house is presently in the framing stage with the owner doing a substantial amount of the work. This is the reason for the long delay in the construction phases. If there should be any questions concerning the design, percolation rate or characteristics of the new site, please call me at (907) 746-1073 or 243-5372. Sincerely, 1,,-, T Douglas T. Kenley, P.E. PE#8176 Douglas T Kenley, P E HC01 Box 6034 Palmer Alaska 99645 (907) 746-1073 March 16, 1996 Mr. Pat Crabb Tract B, Sertich Subdivision Anchorage, Alaska PERCOLATION TEST RESULTS AND GENERAL SITE INVESTIGATION REPORT On November 4th and 5th, 1995, the above -referenced 43,562 square foot site was inspected in conjunction with soil perk tests being performed for application and approval for the installation of an on-site waste water disposal system. The site is located at the northwest corner of 88th Avenue and Abbott Loop Road. The lot drops off from the road level on the east and south side to a depth of one to four feet. The immediate area that has beeen selected for the wastewater disposal system has an average slope of 2%. The site is moderately treed with birch, spruce and alders. The spruce trees are unusally large, indicating average to good soil conditions. On-site observation and physical survey show that there are no water wells nor private wastewater disposal systems within a 100' radius of the proposed system. No surface water was observed at the time of the inspection, and it appears that there is no potential for contamination of adjacent water wells or streams. The proposed well and septic system have been designed to minimize impacts to the adjacent properties. The parcel to the west has a well and septic system installed. Both are outside the 100' protective radius of the proposed well. There is ample space remaining on the property to the west for a replacement septic system. It is a five acre parcel with just one residence on it to date. The property to the north is 297'x 282', with a house situated on the north end of the property 21 feet from the lot line. (See attached sheet.) To: James P. Williams From : Patrick & Deanna Crabb RECEIVED JUN 3 1996 Municipality of Anchorage Dept, Health & Human Services This letter is regarding an installation of a septic system. I have 3$ hrs. of time on the Catapiller 312 excavator which I will be using and 56 hrs. on the Kubota front end loader. I have the engineers drawings to follow the proposed plan. I will install the disposal field, septic tank the way the engineer designed. I will follow all of the M.O.A.s guidelines and codes. Thank You. Patrick Crabb P'�OPJS \ NOISIAicanS HOf1a3S a U a.awvi wn Y _ r -------------------------------- avow dool lloaav I M,£O.ON,49'96t I I OP dpi I I z I I I a a i I F I oe i a o N a I V I, a I W W0 a W I X= / LL I 0 0 � °60l 3dO15 >I ` I I I o I I fI w R- aos -------- ----- J 1N3NISV3 )dmi l '13 OI / 3j6,Z0.05,4994l I Xoo N00 D_� R O ZULL Boz N 1 \ I ItlNStlltl '3E)tlkiOHONtl n o =o NOISIA10ans HOIld9S 4 w U s ., . •.tea 8 lovul g O CF V O 88Vd0 lVd '8W $ o g w s a'< 'L � - o Z SUfn OU Qz d3 C � 3 4 r K 2 U r O� WOO p w O D OW U O K H W O Q UZCC NQ Ww d'J �_ Z O d ¢QF- Z� mW OO X W N W Z d W W UZ FW -K \ _Qd w J U ¢co QOW LL mQO W ¢O ZJ Wmd r'J Q Q W- mw0 QW W 2 O J=¢ JZp d5: Y � cn F -U vzi r wN Nw d � OQ cnr F - (`n O , Zd mO Ij,I QJUu ZQU fnN Oz 0 0 00 M V VJ N NJ 4 LrS (D I- W m w w p d � h O Q Q ao - W U V1 J (n O cz Iw Z U ¢ p K U �p O r Z O O Q Q O II m OCA z(n 1- w N p> w ] -00 04W- 4QFN Q d O m F- z O? O U m S ¢ V O W 4. W Q cn J �• O � rn w=U� oa op W d' � - o Z SUfn OU Qz d3 C � 3 4 r K 2 U r O� WOO p w O D OW U O K H W O Q UZCC NQ Ww d'J �_ Z O d ¢QF- Z� mW OO X W N W Z d W W UZ FW -K \ _Qd w J U ¢co QOW LL mQO W ¢O ZJ Wmd r'J Q Q W- mw0 QW W 2 O J=¢ JZp d5: Y � cn F -U vzi r wN Nw d � OQ cnr F - (`n O , Zd mO Ij,I QJUu ZQU fnN Oz 0 0 00 M V VJ N NJ 4 LrS (D I- W w p d � Q Q ao - W U V1 J cz Iw Z ¢ p K U �p O r Z O O Q Q O II m n m 4 4J VSi W5 dN w ] -00 04W- 4QFN Q d O m F- z O? O U m S ¢ V O W 4. W Q cn J �• O � rn W d V N m O Z �- U U= w N � Qw WwJ� C O J r W 4 O O U ¢OQ J�Q� F.WO Q U FO I -d m Z O0 00 Z W wZ } J Q d rOUCZ9 Z W V ~ �w J O J 0 QO O J dN to Z twn� O i,3Z Om O W d W m (n d Q 0 Q W fn O J d 2 d vii U D OF Z Vl 1- J � - o Z SUfn OU Qz d3 C � 3 4 r K 2 U r O� WOO p w O D OW U O K H W O Q UZCC NQ Ww d'J �_ Z O d ¢QF- Z� mW OO X W N W Z d W W UZ FW -K \ _Qd w J U ¢co QOW LL mQO W ¢O ZJ Wmd r'J Q Q W- mw0 QW W 2 O J=¢ JZp d5: Y � cn F -U vzi r wN Nw d � OQ cnr F - (`n O , Zd mO Ij,I QJUu ZQU fnN Oz 0 0 00 M V VJ N NJ 4 LrS (D I- W PERFORMED LEGAL DESCRIPTION: DEPTH FEE ( T) 1 2- •• Net Time Depth to Water Net Drop ■■■■■■■N 3- 34 ■ 4- 5 5 6 n 7 8- 9- 9 MENE■NN NM. 10- 1011 11 0 12 13- C9 14 C Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST GIQIEER'W q r, 6 .�.__ '{�'L :.tee .• DATE PER FORMED�Y�9. v S�«iCs/75ZTownship, Range, Section: SLOPE SITE PLAN 6 m �OT`ioH 15- 16- 17- 18- 19- 20- COMMENTS 516 17181920 COMMENTS WAS GROUND WATER Ja ENCOUNTERED? S L IF YES, AT WHAT O DEPTH? P E Depth to Water Atter Monitoring? t4— Date: <�2 /-� 2 Reading Date ■■■■■■M. Net Time Depth to Water Net Drop ■■■■■■■N ■ N■■WO■E.■N MENE■NN NM. WAS GROUND WATER Ja ENCOUNTERED? S L IF YES, AT WHAT O DEPTH? P E Depth to Water Atter Monitoring? t4— Date: <�2 /-� 2 Reading Date Gross Time Net Time Depth to Water Net Drop PERCOLATION RATE l7' r (minutes/inch) PERC HOLE DIAMETER 6 TEST RUN BETWEEN FT AND ' FT PERFORMED BY: F,eE`ol� ""`"! I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DAT DATE: 3 R 72-008 (Rev. 4/85) Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG - PERCOLATION TEST �.4T L�P��/1 DATE PER PERFORMED FOR: LEGAL DESCRIPTION: �j�Wnship, Range, Section: SLOPE SITE PLAN DEPTH (F EET) DieG•.�.lJ/L pJE�®u,�.OE/C, 1 r 2 O ' ° o 3 O n 4- 6- r 6 r D' D1'Z' J S14 A1.O al, Mo 7 ° SDn �E G.e-,4 4,/EG 4A -).O g o 9 5 10 WAS GROUND WATER f ENCOUNTERED? a 9 S 11 0 IF YES, AT WHAT _ OL e DEPTH? P 12 _ O E c Depth to Water After 13 Monitoring? 69 Date: O a 14- 15- 16- 17 41516 17 yo4s 18- 19- Reading 819 Reading Date Gross Time Net Time Depth to Water Net Drop 20 PERCOLATION RATE ��' (minutes/inch)GPERC HOLE DIAMETER TEST RUN BETWEEN FT FT AND �T FT COMMENTS PERFORMED BY:FjP�^l7G!/� I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFF TON THIS DATE. ATE: �� 9 72-008 (Rev. 4/85) Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST PERFORMED FOR: ''fir &ELd Zgnw epi y eyve e% � � f •,, e. ..�1�, ice, _p{! 4. fi"!%"a .l• ..` ? . C UGI.'. ;i A!LV DATE PERFOR LEGAL DESCRIPTION:T•Cli4a S�AoWnship, Range, Section: SLOPE SITE PLAN DEPTH (FEET) D,c4✓�6 GIiE� Qz/2pEn� 1 --"�' Sir u1�Soti� G,c7,.gvGL 3 �eouJ.+t�sy ttElJ GoLm ¢60 4 5 6 ` C' ,. 7 D 8 p 9 C� 10 '9 0 m - 11 � m 12 13 0 , IV 14 15 a 16- 17 6 17 o 18 Fj(a C r 19 20 COMMENTS WAS GROUND WATER _ 9 ENCOUNTERED? O S L IF YES, AT WHAT C DEPTH? P E Depth to Water AD(:r ✓%%8'/q6 Monitoring? Date: 4 ■■■■■.■M■ Gross Time Net Depth to Time Water Net Drop NEENNEENN ■■■■■N■■IN ■■.■EEM■■■ 6 z ,�o �_T Z •8 ®EE■M.■.■■ BEY .0, ■■■■■EW■■■ ENNN■ME:!E® .E.■EWI■E■■ ■■■■■.'■.■N ■■■Q-3-13'.■■M O■■■■N■MER ■■■■■■■■E■ 3 Reading Date - Gross Time Net Depth to Time Water Net Drop 4 eq 6 z ,�o �_T Z •8 BEY .0, PERCOLATION RATE /�///'4// (minutes/inch) PERC HOLE DIAMETER 7 TEST RUN BETWEEN �Z FT AND J' FT PERFORMED BY: -e,ee40 lam/• ' �o-AG�y I DOUGH S T. e-PA,G CERTIFY/THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 7 '�� • �� 72-008 (Rev. 4/85) 01