HomeMy WebLinkAboutSHANGRI-LA LT 8Shangri-La
Lot 8
#020-043-26
Municipality ofAnchorage.
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program, 4700 S. Bragaw St. '~ ~'
P.O. Box lg6650 ,~nchorage. AK S9519-~650 Page/ of
www. ci. anc~orage.ak, us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/ORWELL INSPECTION REPORT
Permit Number:, ~w~'bt.~ C./3 O ~- ? 7' PID Numbe~ ~ ~.O
""~"': ~'~n ~- I~,-~vn ~,r Wastewater System: [] New [] Upgrade
P.o. t~o~ {I~OZ~x ~r~c~. ~ c)95't/ ABSORPTION FIELD
Nun'.ber,~ee~'¢cm$* ~"OeepTmtmch 0 ,~l~l{{owTfefl(~ {'{ Bed 0
LEGAL DESCRIPT{ON O. ~ c,o~
We{{: ~ New ~ Upgrade ~. ~ ~,. I{ -- ~'
Y~eM: ~ GPMI Pu~ Set aC I ~ ~ ~ve ~
. ~} 2 ,~ TANK
SEPARATION DISTANCES ~ Sep~c D Holding ~ S.T.E.P. D Othec
Septic Abso~tlon LiR Hol~no
Tank Fietd StaUon Tank S~er~e ~ ~ · ~
Cu~aln
~e..,~,: BENCH MARK
EnglneeCs Stamp
.Inspections pedormed by: FIo~ ~c4 ~C Dates: 1't ~/V/O; ~Y49~
2"~ ~/~/o~ ~.-..-........,..,.,,...
Developmen~ Se~ices Depa~ment Approval .~ ........ ~,,,,.,,,.,
Reviewed and approved by: ~ ~ Date: "/~p]
PERMIT NO: SW030277
SANDPIPER DRIVE
PAGE 2 OF 2
PID NO: 020-043-26
SWING TIES:
FROM: PROP. COR. "A"
TO:
S.T.C.O. "E" 204'
S.T.C.O. "F" 208'
69-FOOT LONG SOIL ABS. TRENCH DBL C.O. "G" 210'
w. 5.5' EFF. SEWER GRAVEL / TR. C.O. "H" 218'
/ TR. M.T. "1" 219'
/
TR. C.O. "J" 226'
REPLACEMENT . / WELL 100'
TRENCH SITE ~ ,.;;;/ .
,,,~' z~.~/y ,," LOT8
TBM ,' -' -'
-~ ,,,, ~.r. ,~Y..~..~C~ ,,- SHANGRI-LA SID
,?' ,/~'y ,,' SEPTIC TANK
100'/
PLAN VIEW
SCALE: 1" = 30"
PROP. COR."B"
180'
190'
192'
163'
196'
229'
183'
CROSS~SECTION
NOT TO SCALE
WELL
~4' SOIL COVER
:i15"~'~:(~XLt:.O~ '~'~.
LOT 8, SHANGRI-LA SID
SEPTIC SYSTEM INSTALLATION
AS-BUILT INSPECTION REPORT
FLATTOP TECIINICAL SERVICES
14530 ECHO STREET
ANCtlORAGE, ALASKA 99516
SCALE: AS NOTED
DRAWN BY TFM
OCTOBER. 2003
FROM : ;~IN~ DRILLING FAX NO. : 9~? ~5 ~ Jul. 31 ~3 ll:~$AM P2
Rick Mystrom
Mayor
Permit Number:. #SW 030184 Date of Issue: ,6-11-03
Date Started: 6-14-03 Date Completed: 6-15-03.
Legal Dc~crlption:
ProperD' Owner ]%me & Address:
Boreholc Data:
Sol! Ty~:. Thie&ness & W~er S~rata
Stick-up
gavelly cobbly silt
bedrock
Parcel Identification Number: 020-043.26
Is reel! located at approved permit location? [] Yes 1-1 No
[] cable tool
Casing t)pe: 1ffeel
Wall Thickness: ,~5~ inches
Diameter: _~ inches Depth: ~7 feet
Liner Type: ,
Diameter:. ~ inches Depth: ~
Casing sfickup above ground: 2 feet
,Shanqd-la Lo( 8
Anchorage Development & Construcffon
944f Abbott Loop Road
Anchom~le, Alaska 99507
Depth (ft) Method of Ih4111ng [] ail' £otary
From To
0 2
8 300
Static water level (from ground level): 8__feet
pumping level: ~00 feet after
~ bouts.pumping _5 gpm
Recovery Rate: _5 gpm
Method of Testing:
Well Intake Opening Type:
[] Open End i~ Open Hole
[] Screened Start__
[] Perforations St,m
Stopped feet
Stopped ~ feet
Volume:/kg
Grout Type: bentonite granules'
Depth: Start Q.0 feet Stopped .9 feet
Pump: Intake Depth feet
Pump size hp Brand Name ......
Well Disinfected Upon Completion? [] Yes [] No
Method of Disinfection: chlodne tablets
Alpino Ddlling & Enterprises
PO Box 110496
Anchorage Alaska 99511
Comments:
Well Driller:.
Attention: The well driller shall provide a well log to the prope~y owner withhq 30 days ofcompletion mad the properU,
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-79O4
ON-SITE WATER SUPPLY PERMIT
Initial
Date Issued: Jun 11, 2003
Expiration Date: Jun 10, 2004
Permit Number: SW030184
Legal Description:JSHANG~i'~!LA SUBDIVISION LOT 8
Design Engineer: 0019 Flattop Technical Services
Owner Name: EARL FORD
Owner Address: 9441 ABBO'iq' LOOP ROAD
ANCHORAGE, AK 99507-
Parcel ID: 020-043-26
Site Address: NHN SANDPIPER DRIVE
Lot Size: 48483 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] SepticTank [] Holding Tank [] Privy
[] Pdvate Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O, Box 196650 Anchorage, AK 99519-6650
w~vw,ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWERfVVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Permit Number SWO;~O/8~
Property owner(s)
Mailing address (1)
Mailing address (2)
Legal description (Lot, Block & Sub'd.)
Legal description (Section, Township & Range)
LotSize '~4~.~ Acres~ .
~. ~(.~ A,~4o~-o¢~ D~ue/o!..~. f Day phone
Zip Code
Number of Bedrooms
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
[] Well Only []
[] Water Storage []
[] Jacuzzi []
[] Water Softening Unit []
I certify that the above information is correct. I further cedify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees:
Date of Payment:
(Rev. 1
Waiver Fees:
Date of Payment:
Receipt Number:
/
~ REPLACEMENT TRENCHi i SEPTIC
I
,,' /-- PROPOSED TRENCH iiii~ia~a
,~' PROP SEPTIC TANK' ~ =' BEDROCK' '~
,'" / // X,' ,~:~ ~ ~ ~ ~,, ~:~::~ LOT0
~ ~ / ~ ~ee,.eee~eeeeeeeeeeeeeee~e~
SHANGRI-~S/D ~0'~ SS' ~' /
''' ':::~::~' :::::: : :::::::'
~OT ~DIUS FROM LOT
~ACAN~ / ~:~/ 14 WELL (ALR~DY DRILLED) ~
/ ....
~ PROPOSED WELL LOCATION
~ SITE P~N
NOTE:
CONFLICT WITH PREVIOUSLY DESIGNATED FLA~OP TECI~ICAL SERVICES 1 INCH = 50 FEET
SEPTIC RESERVE AR~S. THERE APP~RS TO BE 14530 ECtlO STREET D~WN BY TFM
AMPLE SPACE FOR MINOR ADJUS~ENTS TO ANCHO~GE. ALASKA 99fl6 JUNE. 2003
NOTE: THIS IS NOTA SURVEYED P~T.
BOUNDARIES
OF
SEPTIC
RESERVE
AR~S
ALL LOCATIONS SHOWN ARE APPROXIMATE.
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 020-043-26
1. GENERAL INFORMATION
ComPlete legal description
Expiration Date: c~'i'/~,~'~//
SHANGRI-LA ESTATES LOT 8
Location (site address) 16380 SANDPIPER DRIVE, ANCHORAGE, AK 99516
Current Property owner(s) THOMAS & KAREN MARSHALL
Mailing address
Lending agency
Mailing address
Day phone
16380 SANDPIPER DRIVE, ANCHORAGE, AK 99516
Day phone
Real Estate Agent
Mailing Address
THE RAMSEY TEAM - DYNAMIC
Day phone
Unless otherwise requested, COSA will be held by DSD for pickup..
NUMBER'~OFBEDROOMS:
'~P'E OF WATER 'SUPPLY:
', Individual We?
'lndividU~l:Watet Storage
com~Uhity Class'__ Well
Public Water System
4
TYPE OF WASTEWATER DISPOSAL:
[] Individual On-site [~
[] Individual Holding Tank [--]
[] Community On-site r'-]
[] Public Sewer []
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
DSD SIGNATURE
~ Approved for ~
Disapproved.
Conditional approval for
Name of Firm ARCTERRA CONSULTING, INC. Phone 868-3792
Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577
Engineer's Printed Name KENNETH M. DUFFUS Date 04/08/2011
Engineer's Comments: This investigation was completed in corn pliance with ADEC and MOA regulations. The
assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow
and absorption rates may change due to subsurface conditions that may not be observed from the surface,
changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the
water usage of the family being served by the system. The operational life of all well and septic systems are
subject to these various and dynamic characteristics and are outside the control of the
evaluator of the well and septic system. Therefore,
ArcTerra can not give any estimate of how long a ' ' ' .~~.'.'.
system will function satisfactory for current or future ~.. ~"'~i~"i~!'~.~~':~::i'i!i.:':i~, ..:
. -.~'. ~,~;....., !.'~. - . ...,:~..
occupants or can ArcTerra guarantee that no unseen ~t~¢~':'... ' '~"~'~:""' ;~~'~:'~':.'~~.
encroachments, deficiencies or discrepancies exist. ... .... .~...... .. ....... · .... ~,:
bedrooms. ~~
bedrooms, with the following stipulations:
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
X
Arsenic Advisory
Mai'ntenance Agreements
Supplemental Engineer's Report
Other
~dginal certificate Date:.
Municipality of Anchorage
Development SeWices Department
Building Safety DiVision'
On-Site Water& Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www. muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: SHANGRI-LA ESTATES LOT 8
A. WELL DATA
Well.type ~A:~:.lf A,:B,rOF C provide PWSID # . - Well Log Cf/N)_Y
Date completed'6/ZS/2003 Sanitary seal (Y/N) Y_.
Total depth 300 f. Cased to 8 ft. (INTO BEDROCK)
FROM WELL LOG
Date of test 6/1.5/03
Static water level $ ft.
Well produCtion 5.0 g.p.m.
WATER SAMPLE RESULTS:
Coliform NEG colonies/100mL Nitrate 0.876 mg/L
Arsenic: ND. mg/I Date of sample: 3/?.5/2~1 Collected by: ArcTezza
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Sepfic/SteeJ Date installed 8/4/2003 Tank size 1500 gal.
Number of Compartments _2 Cleanouts (Y/N) _Y Foundation cleanout (Y/N) _Y_ Depression over tank (Y/N) N
High water alarm (Y/N) N Date of pumping 3/25/11 Pumper A+
C. ABSORPTION FIELD DATA
Date installed 8/4/2003 Soil rating (g.p.d./ft2 or ff2/bdrm) 0.8
Length 69 ft. Width 2.5 ff. Gravel below pipe 5.5 ft.
Eft. absorption area 759 it2 Monitoring tube Y
Date of adequacy test 3/2.;~1
Fluid depth in absorption field before test 0 in.
Wires properly protected(Y/N) Y_.
Casing height (above ground) 24+ in.
AT INSPECTION
3/25/2011
5.21 g.p.m.
Elapsed l~me: 0__ min. Final fluid depth 0 in. Absorption rate >= 600+ g.p.d.
Any rejuVenation treatment (past 12 mo.) (Y/N & tyPe) N__lf Yes, give date --_~-
Depression over field _N_
Results (Pass/Fail) Pass For ~t bedrooms
Water added 600 gal. New depth 0 in.
Parcel ID: 020-043-26
System type Deep Tzeach
Total depth 8.~9 ft. (Measured 3/25/11)
F=
D. LIFT STATION
Date installed
"Pump on' level at in.
Datum
E. SEPARATION DISTANCES
Size in gallons
"Pump off' level at
Cycles tested
in.
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 100'+
Absorption field on lot 100+
Public sewer main
SeWer/septic Service line 25'+
Animal containment areas 50'+ '
Manhole/Access (Y/N)
High water alarm level at in.
Meets alarm & circuit requirements?
On adjacent lots 100'+
On adjacent lots 100'+
Publicsewermanhele/cleanout :tO(Y+
Holding tank.. 10~+
Manure/animal excrete storage areas lo0'+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+
Water main 10'+
Wells on adjacent lots :tOO'+
Property line .5,+
Water service line 10'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line :tO'+ Building foundation 10'+
Water Service line 10'+ Surface water 100'+
Curtain drain 50'+ (None Known)
COMMENTS
Absorption field
Surface water 100'+
Water main 10'+
Driveway, parking/vehicle storage 10'+
Wells on adjacent lots 100'+
G. ENGINEER'S CERTIFICATION
I certify that I have determined through r~ld inspections and
review of Municipal records ~het the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name KENNETI-I M. DUFFUS
Date 4/08/2011
COSA Fee $490.00
Date of Payment
Receipt Number
(Rev. 11/05)
Waiver Fee $
Date of Payment
Receipt Number
SGS Ref.# 1111053001
Client Name ArcTerra Engineering and Surveying Printed Date/Time 04/06/2011 11:53
Project Name/# SHANGRI-LA Lot 8 Collected Date/Time 03/25/2011 11:45
Client Sample ID SHANGRI-LA Lot 8 Received Date/Time 03/25/2011 14:45
Matrix Drinking Water Technical Director Stephen C. Ede
PWSID 0
SamDle Remarks:
Allowable Prep Analysis
Parameter Results LOQ Units Method Container ID Limits Date Date Init
Metals by ICP/MS
Arsenic
ND 5.00 ug/L EP200.8 C (<10) 03/31/11 04/04/11 NRB
Waters Department
Total Nitrate/Nitrite-N 0.876 0.100 mg/L SM20 4500NO3-F B (<10) 03/30/11 AYC
Microbiology Laboratory
E. Coli Negative 1 100mL SM20 9223B A 03/25/11 DLC
Total Colifom~ Negative 1 100mL SM20 9223B A 03/25/11 DLC
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196550
Anchorage, AK 99519-6550
w,~w.muni, org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. /")~-~) -~'J~ ' -,~"~
1. GENERAL INFORMATION
COSA#
Expiration Date: I ~ - I '7 - O 7
Complete legal description
Location (site address)
Current Properly owner(s)
Mailing address
Lending agency.
Mailing address
Real Estate Agent
Mailing address
SHANGRI LA ESTATES SUBDIVISION; LOT 8
16380 SANDPIPER DRIVE
FLOSSIE BRYNER
16380 SANDPIPER DRIVE
ANCHORAGE, AK .
Day phone, 345-4168
· ANCHORAGE, AK
Day phone
DONNA ORR w// REIdAX PROPERTIES Dayphone 240-7493
110 W. 38th SUITE 100 * ANCHORAGE, AK 99505
Unless othen/vise requested, COSA will be held by DSD for pickup.
2. NUMBEROF BEDROOMS: 4
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank
Community On-site
Public Sewer
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered In the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site waste, water disposal and/or
water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEI~,ENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Certificale of On-Site Systems Approval Guidelines forthis application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with ali applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd.
Phone 357-6179
Address 3701E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY' A. GARNESS, P.E.
Engineer's Comments:
In conducting this evaluation. GEG, LtD. affempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on tho local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being sec'ed by the system.
These conditions ara outside the control of the eva/uator of the system. Satiafactoq/ test
results do not guarantee future performance of the system, nor de they guarantee that
there are no bidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA D~D.~he content of
the ao/e benefit of the owner listed above. Any reliance upoe or use of this report by any
other ~eraon or party is not authorized, nor wi//it confer any legal right whatsoever.
$. DSD SIGNATURE
-' ~' Approved for L./L bedrooms.
Disapproved.
Conditional approval for __
bedrooms, with the fllowing stipulations:
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Reort
Other
By:~'.
Original Certificate Date: ~ 7
[ '~ Municipality of Anchorage ~~ ....
, Development Services Department
Building Safety Dhdsio~
On-Sih. Water & Wastawater Program
4700 Bragaw S~mt
P.O. Box 196650
Archoroge, AK 99519-6650
wwv.munL org/onsite
(9O7) 343-79O4
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Descdption:
A. WELL DATA
Date of test
Static water level .ft.
Well production 5.0 g.p.m.
SHANGRI LA ESTATES SUBDIVISIONi LOT 8
*CASED TO BEDROCK
Well t~13e ~mVA~ If A, B, Or C provide PWSID# N/A
Date completed 6/1.5/2005 Sanitary seal (Y/N) YES
Total depth 500 ft. Cased to *8 lt.
FROM WELL LOG
6/~`5/2oo`1
8
WATER SAMPLE RESULTS:
Callfom~ (~ colordes/100 mi.
Arsenic: .J~ ug./L
SEPTIC/NOLDING TANK DATA
Tank Type/Matedal SEPTIC/STEEL
Tank size 1.500 gal. Number of Compartments 2
Faundation deanout (Y/N) YES Depression over tank (Y/N) NO
Date of pumping 7/25/2007 Pumper
ABSORPTION FIELD DATA
Date installed
Length 69 ft.
N,,~. tq ma~-.
Date of sample: 8/6/2007
Pane ~O: O-~ 0- O/-/g
Well Log (Y/N)
w~es pmm~y pmtect~ (Y/N)
Casing height (above ground)
AT INSPECTION
7/25/2007
26 .ft.
3.7 .g.p.m.
YES
YES
18+ in.
Other bacteria 0 cnionies/100 mi.
Collected by: GEG Ltd.
Date installed 8/4/200,1
~leanout~ (Y/N) YES
High water alarm (Y/N) N/A
Mc0ONALD'S PUMPING
p~IELOW ~XISTING GRAO~ O UTI
Soil rating ~ ~"tbdnn) 0.8
Width 2.5 .ff.
Total depth .8.92 [ Eft. absoll)Uon area 7.59 ifa Monitoring bJt:a~ YES
Date of adequacy test 7/2`5/2007 P~sults (Pass/Fall) P~S
Fluiddepthlnabsarptionfleldbefomtest 7 in. Wateradded 70~gel.
F_tepsed Time: 0 min. Final fluid depth 7 in.
Any rejuvena~on treatment (past 12 mo.) (Y/N & type)
System type DEEP TRENCH
Gravel below pipe. 5,5 fl.
Depression over field NO
Far 4 bedrooms
7 in.
g.p.d.
New depth
Abs~ rate >- 600+
NONE KNOWN If yes, give date
D. UFT STATION
Date installed Size in gallons ~ ~
"Pump on" level at ~lgh wa~ alarm level at in.
~ ~ Cycles testa([ Meats alarm &circuit requirements?.
E. SEPARATION OISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/IR station on icl
Absorption field on lot 100'+
Public sewer main N/A
Ses~r/septic sedco line 25%
Animal containment areas 50'+
On adjacent lots 100'+
On adjacent lots 100'+
Public sewer manhole/ctaanout N/A
Holding tank N//A
Manure/animal excrete storage areas 100'+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+
Water main N/A Water service line 10'+
Walls on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation. 10'+
Water sewice line . 10'+ Surl'aco water 100'+
Cu~lain drain NONE: KNOWN Wells on adjacent lots 100'+
COMMENI~
Absorption field 5'+
Surfaco water 100'+
Water main N/A
Driveway, parking/vehicle sterage 10'+
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspec~x~ and
review of Municipal recorda that the above systems are in
conformance ~ MOA COSA guidelines in effect on this
date.
En~nes~s Printed Name JEFFREY A. GARNESS
Date
Receipt N.mbel' ~ ~' ~/q ~
(Rev. ~ ~mS)
Waiver Fee $
Data of Payment
Receipt Number
SANDPIPER DRIVE
S BcJ 57' OB" E ~ 1 5.48
65.8
SGS Ref. N
Client Name
Project Name/#
Client Sample ID
Matrix
10739330O1
Garness Engineering Group, Ltd.
Shangri La lot 8
Shangri La Lot 8
Drinking Waler
All Daleqrimes are Alaska Standard Time
Printed Date/Time 08/1:5/'2007 16:25
Collected Date/Time 08/06/2007 13:45
Recek'ed Date/Time 08/06/2007 14:00
Technical Director Stephen C. Ede
PWSID 0
Sample Remarks:
Allowable Prep Analysis
parameter Results PQL Units Method Container ID Limits Date Date Init
Met&ls b~ ICP/MS
A~cnlc
ND 5.00 ug/L EP200.g C (<10) 08/13/07 08/14/07 Mil
Waters Department
Total Nitrate/Nitrite-N
2.19 0.100 mg/L SM204500NO3-F B (<I0) 0g/09/07 JDS
Mic~ob~olo~ Laborator~
TotalCollform 0 col/100mL SM209222B A (<1) 08/06/07 SDP
5432 E. Northern Lights Blvd, Suit~
Anchorage, Alaska 99508
(907) 338-4476
Description Price ~,mlt ~mount
Septic tank pumped
Sludge in tank
Leach treatment
Bio-mat in leach
Water level in leach
Cfip on Stand Pipes
Other: r'~.o~c' r>,.,X~,,.
Recommendations:
Total
1.5% interest will be charged monthly on unpaid bills until