ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP221083 PID Number: 015-052-44
Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ® Upgrade
Name
BRET & NANCY BURROUGHS
ABSORPTION FIELD
® Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound
Site Address
9541 ELMORE ROAD, ANCHORAGE, AK
❑ Other
Phone
Number o f Bedrooms
Soil Rating
Total depth from original grade
3
0.8 GPD/SF
13 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
EAST END 7 Ft.
Gravel depth beneath pipe
6 Ft.
Subdivision Block Lot
64A
Fill added above original grade
VARIES SEE DWG Ft.
Gravel length
50 Ft.
Township Range Section
T12 R3W SEC 15
Gravel width
2 Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
600 Ft2
1
-- Ft.
Well
--
100'+
25'+
TANK ® Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
EXISTING
Capacity
Gal.
Surface water
--
100'+
Material
Number of compartments
Lot Line
--
*rj'+
NA
Foundation
--
10'+
LIFT STATION
Manufacturer
Capacity
Gal.
Remarks*2022 MOA WAIVER. TIM ECKLUND MOA
TOTAL DEPTH 13' MAX AT EAST END.
Alarm location
Electrical installed by
Installer MIKE N ANDERSON, PE
PIPE MATERIAL House to tank 3034 d a n Tank to 3034
Drainfield 3034 CO/MT 3034
Inspector FWC / MNA
BENCH MARK (Assumed elevation) 100 ft
Inspdection lst 4/23/22 2M 4/23/22
Location and description
3rd 4/24/22 4`h 4/27/22
GARAGE SLAB
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
.roF A.
Conditional Approval: Date
i
TH
•• •••• ••••.....•
SepticSyste
A�
'. Curtis Huffman
Date"�
�� �'FG, •. CE 128991
�� ��'lF�•. 4/28/2022.-
0 liSSIDN�4
Note: this approval does not include well permit requirements.
kov I
PID: 015-052-44 PERMIT: OSP221083
A—C=46,8'
B—C=24.7'
A—D=44,4'
B—D=58.5'
A—E=47.2'
B—E=55,2'
A—F=70.1'
B—F=44,1'
EXISTING
FIELD
TH22-1
CO
VERIFIED & ATINSTALED---,S.T.BARRIERS AT S.
& FIELD DFCO
W/ STEEL CAPS.,
A
BM: GARAGE SLAB
EXISTING 38R HOUSE
//FCO W/ STEEL �u�u CO MT
RISERS &
CO z BARRIERS--C-0--
p
ARRIERS0 103.1
INSUL
1.250—GALLON 98 I
STEEL TANK
2003 INSTALL
92.9
BM: GARAGE SLAB
CO
F
LOCATED WELLS & PL
— -- _
—INSULATION
PRIOR R TO CONST.
INSTALLED
_
�—
DIVERTER
GRAVEL
C
DRIVE
DCO
Co
EXISTING
S.T. & COS
BI
VERIFIED 100' TO WELL
PRIOR TO CONST.
f FINAL GRADE
FILTER FABRIC
SEWER ROCK
SEPTIC SECTION — NTS
MNA INSTALL
Go
GRADE
98.9/
SM/gm — soft
MNA — RAKED
SIDEWALLS
92.9
TD -12.6'
DRY -4/15/22
LESS THAN
TH22-1
13' MAX 19'
86.5
BOH
2N R3W SEC 15 LOT 64A
SUPPORT SERVICES:
AZ,PREPARED FOR: ��� OF
��
BRET & NANCY BURROUGHS
9541 ELMORE ROAD C *�9TH
ANCHORAGE, AK 99507
FIRST WATER CONSULTING DATE: 4/28/22 tis Huffman
SURVEY: HOLT t 128991
13030 SUES WAY DRAWN: FWCS
ANCHORAGE, AK 99516 SCALE: 1" = 30' 4/28/22
907-350-9566 firstwaterAK©gmail. com PAGE: 1 of 1
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PQ Bux TD W.50 47LID Elmore Rmxf
Ar-dicirage, Alaska SS51!R-6050 Phone: (907) ;i43-79ail Fax: (90 7) 343-7997
hitptf'A%-,m,,v,mtini.arg?cnsO,e
Porynit Number. OSP221083
Work Type. Septic Upgrade
Tax Coriet4umber, 01505244000
Site Legal Address: T1 2N R3W SEC 15 LT 64A 0:2435
F-Imore
Site Mailing Address: 95541 L�RD, Anchorage
Owner BURROLJOKS BRET M & NANCY A
Design Engineer FIRST VIATER CONSULTING
Effective Date.
Expiration Date-,
Lot Size in Sq Ft,
Total Sedroorns;
411 ('2022
411812023
5448G
This permit is for the construction of-,
Disposal rield El Septic Tank 0 Holding Tank 0 Privy L7 Private '.'Vell FJ ItVater Stauage
All Construction sh.911 be in accordance with:
1. Theattai;hed approved design.
2. Alt, requirements specified iri An
c.horage Municipal code Choptar515,55 and 15.e5 and the State of Alaska
Wastewater Di�sposal Regulations (18.AAC72) and Drinking Water Regulations (18AAC'80)
3. The %vastowater rinde rpqiiirr..,z ingpi�O.lon� Haring the irstzllatjQn. ThQ origittPror sihall riotify the Dayelopment
Services Department per AMC f5.65, Provide notiricatlon by caldinei 0077) 34-3-79U4 (24!7).
4, From October 15 to subsurface
April 15� a soil absorption 8-ystern �;ndeT construction during freezing Ymather
shall be either:
a- Opp -tied and Closed on the same day, or
b. Covered, sealed, and Iroated to prevent freezing
RecO.eed By:
Issued By.pry
4/18/2022
Date;
Date�
I
Municipali
P.O. Box 196650 ® 4700 Elmore Road
Anchorage. Alaska 99519-6650 0 (907) 343-7904 0 Fax (907) 343-7997
http://www.muni.org/Onsite
Development Services Department
On -Site Water and Wastewater Section
vARIANCV'-J/WAI"V'r'-jlx'3%.Rr-jV Vi
Waiver#: OSV221023 COSA#: Permit#:OSP221083
PID#: 015-052-44
Legal Description: T12N RM Section 15 Lot 64A
Engineer: First Water Consulting
Applicant: Bret & Nancy Burroughs
n�cnt i
I)c:paruneor
Your request for a waiver of the required 10 feet horizontal separation from the absorption field
to the property line has been approved. The approved separation distance is 5.0 feet. In addition,
your request to install the absorption field perpendicular to slope contours has been approved.
See engineer's waiver request for justifications.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the
on-site wastewater disposal system will require all separation distances be met or another
approval from this department.
■ a a a m m a a a i C a a a a a i a a a a a i a a a a a a a i a i a m i a a a a a a a a a a a a a a m a a a a a a m a a a a a a a a a a a m a a a a m m a a 1
Waiver is Granted: X Waiver is not Granted:
Date: g�o2CJ� Approved by: a6x�_ 6_�&
Name of Reviewer
■■aaaaamaaemamaammamaaaasaaaeaaaaaammaaammmaaaaaaaaaaaeaaaaaamamaaaaaammaaamma.
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 015-052-44
Property owner(s) BRET & NANCY BURROUGHS Day phone
Mailing address 9541 ELMORE ROAD, ANCHORAGE, AK 99507
Site address 9541 ELMORE ROAD, ANCHORAGE, AK 99507
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section) T12N R3W SEC 15 LOT 64A
Lot Size 54,480 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR:
(® all that apply)
.Upgrade
Absorption Field
Renewal
Septic Tank
❑ ...
Holding Tank "
Privy
Private Well
❑
Water Storage
❑
APPLICATION IS AN
Initial
❑
.Upgrade
❑
Renewal
❑..
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
TYPE OF DWELLING:
Single Family (SF) ❑
(w/wo ADU)
Duplex (D) ❑
Multiple Dwellings ❑
(SF and/or D)
FIELD -- PERP TO SLOPE & WITHIN 10' OF N PROP. LINE Distance: TBD
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment: �i �� 5 % o� 0 9
Receipt Number: a 1 51 b q
Permit No. Q S r,�� 1 0? 3
Waiver Fees: $ a 0 FJ
Date of Payment: _
Receipt Number:
Waiver No. D�S V �Q 1 ?j
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
13030 Sues Way, Anchorage, AK 99516
907-350-9566 / firstwaterAK@gmail.com
April 15, 2022
Municipalities of Anchorage
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
RE: SEPTIC SYSTEM UPGRADE PERMIT WITH WAIVERS
LEGAL: T12N R3W SEC 15 L64A 9541 ELMORE ROAD
The property owner has requested we obtain a permit to upgrade the failed septic system of the
above referenced lot. We propose to install one deep trench to serve the existing 3-bedroom
residence. The design is based on the recent test hole conducted on April 8, 2022. No
groundwater was observed at test hole excavation or monitoring or in the surrounding soils data.
The slopes are moderate at 5% at the proposed upgrade location. The trench will be
perpendicular to slope and within 5 of the north property line and we request waivers as shown
on the design. We took elevation shots of the area and also propose to verify existing septic tank
barriers and protections of the existing system at construction. We proposed to keep both the
existing and proposed fields via the proposed diverter. The lot and area are served by private
water. The design will not impact any of the neighboring properties. Please contact us if you
have any questions.
Sincerely,
Curtis Huffman, P.E.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221083, Rebecca Carroll, 04/18/22
Project Name: OSP221083
Project Description: T12N R3W SEC 15 LT 64A
Review Comments List Date: 4/18/2022
Changemark note #01, DESIGN PG2.pdf
Please address the change in elevation over the length of the field and how to ensure that the entire
effective depth is in the perked SM/GM layer.
Responded by: BRENT WESTERN - 4/18/22 2:38 PM
We took elevation shots of the proposed field area (5% slope) and the DCO. The existing DCO is 4'
from grade so 4.5' at the proposed field lateral mid point of the 501 trench. Using the elevations and
proposed field run of 50' there is about 3' of elevation difference and the testhole /groundwater is
ok. we can always do a confirming TH too if need be. The western lower proposed trench end is 3'
from grade, the middle at 4.5' and the upper slope at 6' with a total of 6' ED that is -12' TD or 1' of
fudge room. it was designed conservatively speaking. You can always place a permit note if need be.
Thanks!
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221083, Rebecca Carroll, 04/18/22
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221083, Rebecca Carroll, 04/18/22
4661
13030 Sues Way - Anchorage, Alaska 99516
Tel. 907-350-9566 firstwaterAK@gmail.com
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: T12N R3W SEC 15 LOT 64A
PERFORMED BY: FWCS / FWC & MIKE N ANDERSON, PE - I CURTIS HUFFMAN CERTIFY
THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL
GUIDELINES IN EFFECT ON THIS DATE. DATE: 4/15/2022
DEPTH
FEET OG
SOILS
1
ORG/OL
2
3
4
5
6
7
8
SM/gm - soft
9
10
11
12
13
14
15
16
17
18
19
20
BOH
Reading Date Gross
Time
Net
Time
Depth to
Water
Net Drop
4/14/22 30 min 6 3
30 min 6 3 1/16
30 min 6 3
PERCOLATION RATE 10 (MIN / INCH)
TEST RUN BEWTWEEN 5 & 6 FT
PERC HOLE DIAMETER 6
PRE-SOAKED PRIOR TO TEST & ALL READINGS TO
THE 1/16TH.
GROUND WATER ENCOUNTERED: NO
IF YES, AT WHAT DEPTH: NA
DEPTH TO WATER AT MONITORING: DRY
DATE: 4/15/2020
TESTHOLE # 22-1 DATE PERFORMED: 4/8/2022
SEE SITE PLAN FOR SLOPE & LOCATION
COMMENTS:
VERIFY GROUNDWATER MT & WELL & PL
AT TIME OF CONSTRUCTION
PERFORMED FOR: BRET & NANCY BURROUGHS
4/15/22
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221083, Rebecca Carroll, 04/18/22
Municipality of Anchorage ,•'"' '';•,
.� Development Services Department
i Building Safety Division
On-Site Water and Wastewater Program, 4700 S. Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650 Page I of 3
www.ci.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: SW030452 PID Number: 015-052-44
Name: Gary & Judy Skaggs
Wastewater System: ❑ New El Upgrade
Address. 9541 Abbott Loop Rd., Anchorage, 99507
ABSORPTION FIELD
Phone. 346-3335 Number ofBadrooms: 3
1 Trench O Shallow Trench❑Bed ❑Mound ❑other.
LEGAL DESCRIPTION
Sol Rating
Total Depth from original grade:
GPO/F!'
Ft.
sion:
Block: Lot: c 4 A Subdivision:
Depth to pipe bottom from an grade:
Grevel depth beneath pipe:
V•�
FI.
Ft.
Township: 12N Range. 3v1/ ion: 15
Fill added above original grade:
Gravel Length:
Ft.
Ft.
We ❑ New ❑ Upgrade
Gravel width:
Numbs doer.
Distance between Ines:
.
FI.
Ft.
Classification (Prate, A,
Trial Depth:
Cased to:
Total absorption was:
Pipe Material:
Existing
Ft. I
FL
Ft'
Driller:
Da led:
Static Water Level:
Installer.
1{
Date installedQ / �I ' � �
llll •�
FL
YmNd:Pump
Set at
Casm^B Hem Grou^d'
TANK
GPM
FI.
SEPARATION DISTANCES
ElSeptic El Holding ❑S.T.E.P. ❑Other:
To
From
septic
Tank
Absorption
Field
Lift
Station
Holding
Tank
lublictPrivate
Sewer Line
Manufacturer;
Anchorage Tank
Pauly:
1250 Gal.
Material:
Number of Compartments:
wen
130
145
NA
NA
NA
steel
2
Surface Water
100+
100+
NA
NA
LIFT STATION
mze:
en adurer.
Lot Lim
30+
15+
NA
NA
V
NA Gal.
9
'Pump on' level at:
'Pump olr level at:
Wgh watt/ alarm at
Foundation
5+
15+
NA
NA
�,,
a,.
In.
NA
NA
NA
NA
Pump Make d Model
Elecperformed trical Inepecbons perfoed by:
carlein Drain
Remarks: Tank changeout. Old tank was removed and a
BENCH MARK
new tank put in its place. Two double cleanouts
Locabon and Description:
garage slab
mad bvalwn:
installed. Barriers installed around the tank
FL
100.0
to prevent driving over it; it is partially in the
driveway.
En
*' 4_9TH'
Cindy W. Ellis, P.E. at 10/25/03
Inspections performed by: y Dates: 1
•:>♦•
+F• ••/y��
"
NA
L'• ria j J
Y ��
2nd
Cin
Development Services Department Approval
0%... W. Ellis;
.
CE
by: Date: b
=�
��.• -10577
Reviewed and approved
(Rev. IZ'eb)
r°4pFfS$IONAt-G/�i��c
A9
S 89°59'21 "W 3313.18'
Exis ingttrainfield----.__ Existing 1250 gal septic tank removed.
i C3— New 12b0 gal-steetseptic tank installed._
_DC 3-
1e s around tank (5) 4x4 post Barriers °RA%'eL
r
+' ,SBM DC01 2 TST1 C
j B \'
I, A
1ALT Existing 3 BR house
I
' J
j Existing well 100 ft r iuk '�
Property Line
_U
A
B
DC01
40.0
10.8
DCO2
40.0
it5
55.3
ST1
40.3
12.3
55.3
43.7
19.7
56.0
DC03
44
21.8
56.8
DC04
44.7
22.8
57.2
Well serving lot 64A
ASBUILT
100 ft well radius
Lot 64A
Lot 65B
Septic Upgrade for Gary & Judy Skaggs
T12N RM, Sec 15, Lot 64A �'
_*��49LH
Watkins Engineering, Inc DATE: 11/01/03�"`''`'"
CindyW. Ellis, RE . CiriPY W. Ellis
PID No. 015-052-44
P.O. Box 110443 Scale: 1° = 30 ft •. ce-+0577
Anchorage, AK 99511 "'c0-'1
�^'
Phone (907) 349-1851; Fax 349-1934 Permit No. SW030452
Final Grade: 101.52
ST1 ST2
98.46
2" rigid insulation
97.98 / 1250 gallon steel
septic tank 97.67
Tank Profile ASBUILT
No Scale
OF.. A p�
"'�'�.sVup
T12N, R3W, Sec 15, Lot 64A Parcel ID 015-052-44
����`� '
Septic System Upgrade permit # SW030452
0���' 49 rH % p,
Gary &Judy Skaggs
.:.....:......• ...,_::....�
1,14d4 D��� �:,
GC.y"' ' CWD
0
0�
Watkins Engineering, Inc.
10577 •`
C�4•�^
Cindy W. Ellis, P.E.
v •�
*8Dio ,
�G�
November 4, 2003
Ir
O'Z IO3-3rryi
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Permit Number: SW030452
Legal Description: T12N R3W SEC 15 LT 64A
Design Engineer: 0844 Watkins Engineering, Inc
Owner Name: GARY & JUDY SKAGGS
Owner Address: 9541 ABBOTT LOOP RD
ANCHORAGE. AK 99507-4223
Date Issued: Oct 22, 2003
Expiration Date: Oct 21, 2004
Parcel ID: 015-052-44
Site Address: 009541 ABBOTT LOOP RD
Lot Size: 54480 SO. Ff.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
❑ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy
All construction must be in accordance with:
1. The attached approved design.
❑ Private Well ❑ Water Storage
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
1
5:'The" following'speciai provisions" -
tA PERMANENT BARRIER SHALL BE INSTALLED BETWEEN THE PROPOSED SEPTIC TANK AND THE
.DRIVEWAY TO PREVENT VEHICLES FROM DRIVING ON THE SEPTIC TANK.,
Received By.
Issued By:
Date:
Date:/Q/2 2103
Municipality of Anchorage
t"
Development Services Department 4
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 015-052-44 it Permit Number SW 03043-2
Property owners) Gary & Judy Skaggs Day phone 346-3338
Mailing address (1) 9541 Abbott Loop Rd
Mailing address (2) Anchorage, AK Zip Code 99507
Legal description (Lot, Block & Sub'd.) T12N R3W, Sec 15, Lot 64A
Legal description (Section, Township & Range)
Lot Size 54,480 Acres Sq.Ft. Number of Bedrooms 3
THIS APPLICATION IS FOR:
SWell Only Elewer Only ❑
Sewer and Well ❑ Water Storage ❑
Sewer Upgrade a- iik 6o ❑
THIS PROPERTY CONTAINS:
13
Jacuzzi
Hot Tub ❑
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
PE,
(Signature of property owner o&thorized agent)
Permit Fees: L1h7 I, Waiver Fees:
Date of Payment: �'� 170 NT Date of Payment:
Receipt Number: Receipt Number:
(Rev. 12100)
Watkins Engineering, Inc.
P.O Box 110443, Anchorage, AK 99511
(907)349-1851 cwellis®gci.net
October 20, 2003
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
RE: T12N R3W, Sec 15, Lot 64A
Septic Tank Replacement
To Whom It May Concern:
Attached please find an application to install a new 1250 gallon steel septic tank at the
referenced 3 bedroom house in Anchorage. The existing steel septic tank was installed
in 1983, and a hole was found in the tank during a repair. It will be removed and the
new tank set in the same place. A foundation cleanout will also be installed. The
drainfield has been tested and no work is proposed for it.
There are no surface water concerns, and the new tank will be placed more than 100 ft
away from any private wells. I am not aware of any adverse effect that this upgrade
would have on any adjacent properties' water and wastewater treatment needs.
Thank you for consideration of this permit application. If you have any questions or
need further information, please call me at 349-1851 or 360-3389 (cell).
Yours truly,
Cindy Illis, P.E.
President
v
M
G:
Class C well
CL
Lot 57
O
J
Vacant
Lot 58
0
.n
.n
B B9'59'21W 330.18'
� 200 ft well radi s
0
o
Lot 63to
CO
0
b
„
j Lot 64A �w
o
b
B
---- — —
Hrn
-----------
East 96th Ave. 100 ft well radius
LL SERVIN LOT 64A�
Vacant
,\100 ftwell radius
Appro imate well location
0
Lot 65B
Little Tiny SID Lot 1
11�J
Lot 72
Septic Upgrade for Gary & Judy Skaggs '�`'" A'�
T12N, RM, Sec 15, Lot 64A 49- TH�
r
Watkins Engineering, Inc. DATE: 10/17/03�"� -"
Cindy W. Ellis, P.E. PID No. 015-052-44`• Ci dy W. EIIIS ;
Scale: 1"= 100 ft CE-10577 ;
P.O. Box 110443 Taken from Shane Holt Survey, LS-6914
Anchorage, AK 99511 October 15, 2003 ssiow�
Phone: (907) 349-1851: Fax: 349-1934
S B905912 1 "W 330.1 8'
----:__-Existing drainfield. No
I worcT—prbposed-----__.__
--
DCO ------------------------ .�-
Existing 1250 gal septic tank.oR,
----------- -anEN,Av \
�-To be removed d a new �2�� g
Install FCO steel septic tank install \
Tank to house 5 ft
�I i
ASP SALT Existing 3 BR house i
' J
j Existing well 100 ft r iuk
Property Line
Well serving lot 64A
100 ft well radius for Lot 65B well
Lot 65B
100 ft well radius
Septic Upgrade for Gary & Judy Skaggs
T12N RM, Sec 15, Lot 64A
Watkins Engineering, Inc
Cindy W. Ellis, P.E.
P.O. Box 110443
Anchorage, AK 99511
Phone (907) 349-1851; Fax 349-1934
DATE: 10/20/03
PID No. 015-052-44
Scale: 1" = 100 ft
Lot 64A
1 _
5 • ET
Clgdy W. Ellis
M iom
H
SAFE
f
F.ASI'M�'Pr'"
^"7,i,VALL� CQN11IDEP/TION, JADES W. CO'JP,LEY and 11AF• E.
i...... an! Wrifc, hereinafter referred to n- OFANT')V20
and r;ONVEY reasonable right: of inarc:: and
lc._at^d on the followlnr, descrlbcd reel i,rnoert:r:
Lot G5, Section 15, Township .12 North,
P 3 West, Seward,Mcridlan; in the
Inchova;�e Recording, District;.,^rird
:7l.:trIet, State of Alaska.'::•'
:c o;;%p LL EVER : i WELLS and MARINE IIAP•IE WELLS, husband
!:erclnaftcr referred ts','as,GRA`ITEES, their heiro,
ur•c:: �r.:
and a -::inns and shall'not run with the land. Said
•. '.nll !.�
u. --ed ',nly by the GRANTEES, thetlr heir-,
:c.. a::i a:..:l r..• and --hall not be used by the nubl'_'..
Tha GiiA;1;'=", their heir--, cuccezzorz and a:.ziirns, here-
�'';rec :•rlth the GRAt. FS, their heirs,succeaoors and a::--lgns,
if tno :•cell located on the above-described real prop^rty is
jj1,ar.dorv:d,lf read In built, or abandoned for an9.other rea--on, the
:aA;:':EE•;, their heirs, succesnors.and assigns, shall fill the well
lt!. acccptatle fill material,at the .GFAIITEES, their heirs,
:u^c1:.7• :r:! and expense. ,J�
D LD this, �,�C clay of , / �l+C6T 1474.
i .-ALL °Srii!:E'i": 'r;CLL3, G1'aC1LCN �' J tdES '' , GUUHLEY, Grantor
'I , . ' / iG/ L. `t' �, , •�.. Vic/
;;AA I iE i,IARIE WELLS, Grantee 11:, A a GOU RL: ,vGrantor,:
j
'i urS IS i0 C!i!:PI:'Y that an thS: T?/ da" of Xi1,/
:11tnte cf Alasku,'10�perronallyyappeared OP.RALLuEVhe under.. a No ERETT and ."o
I•IAR1E WELLS, known to ,ne and Y•nonn to be the individuals
q.nmrcd in and ::he executed the foregoing'instrunent and they acknow-
I�cd,-ed to ne that they sirned the Dame freely and voluntarily for
;I Lc u-nz and purpose:: therein stated.:'
A
1T.1wSa n:i hand and official seal the day and year last
9:::0:•-• .rltten.
DAER, BARKER
e.' & NANGLE
AT,ORNE" AT LAW
7Q1 --It 3tRCCT. EUITC !
ANLNtMAGC. AL^!. A
D1,M,
• . .'(.
,,:,•, notary ,Public in and I'er, Agaaka
• •r. ;Commission exDirCy
-1-
I
O CFfP.".'TFY that, cn thic da, of ��<•I .�
the ur:era/Encd, a Notary.Putlie in and Tor thr-•
r,f ; appeared"JAM25 W.'I GOUnLEY, and 14.1E E.
::is f^raon111;;
'rna:Ir. to �I! and knewn ;to be 'the individuals named in and
�•r.;.,,.;Ir1 :ia; forerolnr instrument and they acknowledced to ne
••:. • tt:^? .::rn^d t�,^ name freely ,and voluntarily for the uzcs and
t.
'r:^•Jif, tili•CII.
I,
Zt
my hand and official deal the day and year la"
otary ubl c n an or Ala ka
i14y:Co+nnission'expires /7
i; h I �1 C ? "r� it • _
i 74..
I
ea ,
II
r
�I
N
,I
•
BAER, BARKER
6 NANGLE
i
AII(IRNE" At LAW
INN •'If' SIR[ L I. SUI IE I
ANCIK AGE. ALAV_ A
:n IN.
I
,1
i�
'NAME
MUNICIPALITY OF ANCHORAGE
DEPARTMENT QF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE [)ISPOSAL SYSTEM AND/OR WELL INSPE!CTION REPORT
PHONE
[]NEW
~I3~PGRADE
MAILING ADDRESS
EGAL DESCRIPTIQN
LOCATION
O,STANCE TO: I
ILq. c pacity ngalons]
Manufacturer
DISTANCE TO:I
~P I T°P °t tile t° finish grade ¢/
%; Length Width
~ ~ Type of crib Crib diameter
Foundation
Total length of lines
NO. OF BEDROOMS
PERMIT NO.
No. of compartments
Liquid depth
Dwelling PERMIT NO.
LiquM capacity in gallons
Material beneath tile
OTHER
PIPE MATERIALS
~OI L TEST FCATI NG
INSTALLER
REMARKS
Depth
Crib depth
Material
Nearest lot lin~,~ ~¢_ ,/
Trench w'dth
PERMIT NO.
Distance between lines
Total effective absorotion area
PERMIT NO.
DATE
tO-
APPROVED
Total effective absorption area
BuiMing foundation Nearest lot line
Driller Distance to lot line PERMIT NO,
Sewer line Septic tank Absorption a~ea(s)
LEGAL
72-013 (Rev. 3/78)
oGRE
':R ANCHORAGE AREA BOR"'IGH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME /~o~£7~T- ~L2/~/- ~, MAILING ADDRESS ¢?: ~// ,~)D'/yd?-2 /.r.o~ ~°!) PHONE }J~/~/~/~C'
LOCATION ¢4¢¢//
SEPTIC TANK:
DISTANCE
FROM WELL ~0 ~ __MANUFACTURER
INSIDE LENGTH INSIDE WIDTH
MATERIAL
NUMBER OF
_ COMPARTMENTS.
LIQUID DEPTH _____LIQUID CAPACITY//~g~O GALLONS.
SEEPAGE PIT:
NUMBER OF PITS ~ --. DIAMETER OR WIDTH/?'/'~[ L. ENG'[H/~-_/,/ DEPTH ~ / ~
LINING MATERIAL(%No~-*Z:T/ ~]¢~RIB SIZE:/C~uDIAMETER__DEPTH _ DISTANCE FROM:
TOTAL EFFECTIVE
BUILDING FOUNDATION(~¢'/ , NFAREST LOT LINE~2¢~ . ABSORPTION AREA (WALl_ AREA)
WELL /
.SQ. FT.
ADDITIONAL ABSORPTION
WELL:
TYPE (~" / ] ~' L~ /~'~
BUILDING
FOUNDATION
CESSPOOL
APPROVED
CONSTRUCTION
NEAREST
LOT LINE
OTHER SOURCES__
_ DISAPPROVED__
NEAREST
SEWER LINE
REMARKS
DEPTH DISTANCE FROM:
SEPTIC SEEPAGE
TANK SYSTEM
DISTANCES:
INSTALLED BY:
PiPE MATERIAL: (~/],~,~/ -,/~
LOT SLOPE: ]V ~ /~ L~.
REMARKS:
Form NO, EQ-O31
DIAGRAM OF SYSTEM
DATE
APPROVED ~ ~'-L~/- C~.~ ~
G.A.A.B.
Permit ~
Applicant: ~./~ ~/.~
Location:
Type of Soil Absorption System Is:
Trench: _~/. Drainfield:
Maximum Number of Bedrooms: ~
Department [ Health and Environmenta 7rotection
825 ~ Street, Anchorage, AK. ~9501 /~
264-4720 ~
* * * HANDWRITTEN PERMIT * * * -
WELL AND/OR ON-SITE SEWER PERMIT
Phone Number :'~Z//Z/-- Z~~69
S ~ ~/~"T Lot Size:
Seepage Bed: __Holding Tank:
Soil Rating(sq.ft/br) /~
The Required Size of the Soil Absorption System Is:
DEPTH /~I ~-' LENGTH ~-' GRAVEL DEPTH ~/'~- WIDTH
The length dimension is the length(in feet) of the trench or drainfield. The
depth of a trench or pit is the distance between the surface of the ground and
the bottom of the excavation(in feet). There is no set width for trenches.
The gravel depth is the minimum depth of gravel between the outfall pipe and
the bottom of the excavation(in feet).
* * REQUIRED SEPTIC(HOLDING) TANK SIZE = /~E;<~ GALLONS
Permit applicant has the responsibility to inform this department during the
installation inspections of any wells adjacent to this property and the number
of residences that the well will serve.
* * * TWO(2) INSPECTIONS ARE REQUIRED * * *
Backfilling of any system without final inspection and approval by this department
will. be subject to prosecution.
Minimum distance between a well and any on-site sewage disposal system is 100 feet
for a private well or 150 to 200 feet from a public well depending upon the type
of public well. Minimum distance from a private well to a private sewer line
is 25 feet and to a community sewer line is 75 feet. Well logs are required
and must be returned to this department within 30 days of the well completion.
Other requirements may apply. Specifications and construction diagrams are
available to insure proper installation.
* * * PERMIT EXPIRES DECEMBER 31, 1 9 8 3 * * *
I certify that:'
(1) I am familiar with the requirements for on-site sewers and wells as
set forth by the Municipality of Anchorage.
(2) I will install the system in accordance with codes.
(3) I understand that the on-site sewer system may require enlargement if
the residence remodeled to
is include more that/~m~edrooms.
Applica
Da he: /r~
SWP/024(1/81) ' i {- ivy.(. (_~c I o [ ~
NAME Of APPLICANT
GREATER ANCHORAGE AREA E'~OROUGH
PERMIT NO,~
SEWAGE DISPOSAL SYSTEM -- APPLICATION ANi) PERMIT
COMPLETION DArE ANTICIPATED
, OTHER
TO BE INSTALLED BY ---~'-~"~
/
e ~ ~.~,tZ~__. NOTE: THIS PEI{MIT IS NOT VALID WITHOUT
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTFI AND ENVIRONMENTAL PROTECTION
825 L. Street, Anchorage, Alaska 99501 264-4720
SOILS LOG - PERCOLATION TEST
~'"~i LS LOG
PERCOLATION
TEST
1
2
3
4
5-
6
7
9
10
11
12
13
14
15
16
17
18
19
2o
SLOPE SITE PLAN
WAS GROUND WATER S
ENCOUNTERED? ~J ~,
L
O
P
E
DEPTH?
Gross Net Depth to Net
Reading Date
Time Time Water Drop
PERCOLATION RATE
(minutes/inch)
COMMENTS
TEST RUN BETWEEN
FT AND FT
PERFORMED
CERTIFIED BY:.
DATE-:
Performed For ~
Legal Description:
This Form Reports Soils L, og
Soil Test Must Be Logged To 4~
Depth
Feet Soil Characteristics
10--
11--
12--
13--
14--
GREATER ANCHORAGE AREA BOROUGtl
DEPARlMENT OF ENVIRONMENTAl. QUAi. ITY
3330 "C" Street
ANCliORAGE, ALASKA 99503
Case #
Dated Performed ~-~-T&
Subdivision ~ ?~ 72z~/' ~u)
Percolation Test
Below Proposed Seepage System
Was GroLind Water Encountered?
If Yes, At What Depth?
Reading Date Gross Time Net Time Depth to H20 Net Dro
Percolation Rate
Proposed
Depth of Inlet
COMMENI'S:
Minute
Installation: Seepage Pit
Depth
Drain
to Bottom of Pit or
F i e I d
Trench-
Test Performed BY
Date Certified BY:
~-~. /~A~.~_ Date -~- M~
: ~= ...... ::_ .......
GREATER ANCltORAGE AREA BOROUGH
DEPARTMENT OF ENVIRONMENTAL QUALITY
3330 "C" Street
ANCHORAGE, ALASKA 99503
Performed FO r__J~L.~ ~t~
Legal Description: Lot
This Form Reports Soils
Soil Test Must Be Logged To
Depth
Feet Soil Characteristics
7-~
ll--
Encountered?~_O _
Was Ground Water
If Yes, At What Depth?
Case #
Dated Performed ~Z~____
I$~ Subdivision '~-I~ ~q~-~.~
Percolation Test
4' Below Proposed Seepage System
Reading
Date
Percolation Rate
Proposed Installation:
Depth of Inlet
COMMENTS: /so
Gross Time Net Time Depth to N20
Net Dropl
M i n u [ e
Seepage Pit
Depth to Bottom
Drain Field
of Pit or Trench
Test Performed 13Y_z~.~ ~~ Date Certified BY:
Date:
MUNICIPALITY OF ANCHORAGE
10
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 015-052-44
1. GENERAL INFORMATION
Complete legal description T12N R3W SEC 15 LOT 64A
Expiration Date: 9 -21 r Z -©ZZ
Location (site address) 9541 ELMORE ROAD, ANCHORAGE, AK 99507
Current property owner(s) BRET & NANCY BURROUGHS Day phone
Mailing address
Real estate agent
9541 ELMORE ROAD, ANCHORAGE AK 99507
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
3
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
®
Private Septic
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ ',-"go
Date of Payment y�r' h-2
Receipt Number 7 ( G 2.5L�
COSA 2-116
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Address 13030 SUES WAY, ANCHORAGE, AK 99516
Engineer's Printed Name CURTIS HUFFMAN, PE Date 4/26/2022
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to �.. or— e / ��
these various and dynamic characteristics and are outside the control of the evaluator of the "�•�Q
well and septic system. Therefore, any estimate of how long a system will function satisfactory rg�Q: •' • . • !fes
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting & TH • '.
Stars77,
6. DSD SIGNATURE "" "'v'�'
Curtis Huffman
System #1 Approved for bedrooms ����F9�s•, CE 128991���
System #2 Approved for bedrooms l\��PROF S5Q0 r
Disapproved
Conditional approval for bedrooms, with the following stipulwRl �Iw:((t w(
OF
Q7 VVATER AN
P
TER
BY Original Certificate Date: S� Z^ Z©zZ
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
Legal Description: T12N R3W SEC 15 LOT 64A Parcel ID: 015-052-44
If more than 1 septic system on lot: COSA Checklist # of
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled CIRCA 1973
Total depth 178+ ft (ASSUMED - MOA DOCS)
Cased to 40+ ft (ASSUMED - MOA DOCS)
® Sanitary seal is functioning correctly
® Wires are properly protected
Casing height (above ground) 12+ in.
Date of flow test for COSA 4/20/22
Static water level at beginning of test 151 ft.
Comments
B. TANK DATA
Age of tank(s) 19 years
Tank type/material SEPTIC / STEEL
Measured operating fluid level in septic tank 50"
® Standpipes/foundation cleanout per record drawing
Date of pumping 3/4/2022
D. ABSORPTION FIELD DATA
Which system tested (date installed) NEW SYSTEM
® ALL standpipes present per record drawing
Total measured depth from grade 10.2 ft (max)
Measured depth to pipe invert from grade 4.2 ft (min)
❑ NIA — pressurized field
® Monitor tubes go to bottom of effective. If not, state
depth into effective
Structure served by this system _
Well production at time of test 4+ gpm
Water storage tank volume NA gallons
Well disinfected for coliform test? ❑ Yes ® No
® Coliform bacteria is Negative
Nitrate 4.38 mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ® Arsenic less than MRL (ND)
Collected by°
Date of Sample 3/7/2022
C. LIFT STATION
❑ Required maintenance completed
Age of lift station years
Lift station material
Comments:
Adequacy test date NEW SYSTEM
Results M Pass For 3 bedrooms
Fluid depth prior to test _ in
Water added gal
New depth in
Elapsed time min
®Code -required soil cover over field
Final fluid depth in
❑ System presoaked Absorption rate gpd
(Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N
date of test) If yes, enter date
Gallons introduced gallons F��
Comments/Deficiencies:WEST CO & MT AT GRADE. F
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
® Yes
if No
Community Sewer Manhole/Cleanout > 100'
® Yes
if No
ft
® Yes
if No
Neighboring Tank > 100' ® Yes
if No
ft
Private Sewer/Septic Line > 25' ® Yes
if No
Absorption Field on Lot > 100' ® Yes
if No
ft
Holding Tank > 100' ® Yes
if No
Neighboring Absorption Fields > 100'
Water Service Line > 10'
® Yes
Animal Containment > 50' ® Yes
if No
® Yes
if No
ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' ®Yes
—
if No
ft
®Yes
if No
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
® Yes
if No
ft
Surface Water > 100' ® Yes if No
Property Line > 5'
® Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
® Yes
if No
ft
Private Wells >' 100
_ ®Yes if No
Water Main > 10'
Yes
if No
ft
Community Wells > 200' ® Yes if No
Water Service Line > 10'
® Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
® Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
❑ Yes
if No
*5 ft .
Wells on Adjacent Lots:
Water Main > 10'
® Yes
if No
ft
Private Wells >' 100
_ ®Yes if No ft
Water Service Line > 10'
® Yes
if No
ft
Community Wells > 200' ® Yes if No
Surface Water > 100'
® Yes
if No
ft
F. ENGINEER'S COMMENTS
*2022 MOA WAIVER # OSV221023
G. ENGINEER'S CERTIFICATION
l certify that l have determined through field inspections and review
of Municipal records that the above systems are in conformance
with MOA COSA guidelines in effect on this date.
.lw��.�.a�,�01
Age
.. .... • ....�..�... .
Curtis Huffman 1�
CE 128991
� OFESSOV��o�
ft
ft
ft
ft
ft
ft
ft
ft
mloozolm
&» #gL M�zt§O.O N
G VOS 3SO11V /3
E®§ z
\
i
§)_
9 D0
-
\
Municipality of Anchorage
Development Services Department
-Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 015-052-44 HAA #�1
Expiration Date: 2 ' Co — Qq -
1.
q-
1. GENERAL INFORMATION
Complete legal description T12N R3W Sec 15 Lot 64A
Location (site address or directions) 9541 Abbott Loop Rd, Anchorage, AK 99507
Current Property owner(s) Gary & Judy Skaggs Day phone 346-3338
Mailing address 651 E. 100th Ave., Anchorage, AK 99515
Lending agency First American Title Co. ! Estelle Day phone 786-9531
Mailing address
Real Estate Agent Day phone
Mailing Address
.Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 3
3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well Individual On-site
Individual Water Storage ❑ Individual Holding tank ❑
Community Class Well ❑ Community On-site ❑
Public Water System ❑ Public Sewer ❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given In paragraph 4 by an Independent professional civil
engineer registered In the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with
new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.)
Certificates are valid for one year for properties served by Class A or B wells or a public water system. The
Municipality of Anchorage Is not responsible for errors or omissions In the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seat affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system Is(are) safe, functional and adequate for the number of
bedrooms and type of structure Indicated herein. I further verify that based on the Information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation.
Name of Firm Watkins Engineeing, Inc. Phone 349-1851
Address P.O. Box 110443, Anchorage, AK 99511-0443
Engineer's Printed Name Cindy W. Ellis Date /t -4-e">
5. DSD SIGNATURE
Approved for -3 bedrooms.
Disapproved.
Conditional approval for bedrooms, with the following
49Ri*
toy W. Ellis
CE -10577
INARiEWATFR
�- nn nnn All • _
Attachments:
HAA Checklist X
Septic System Advisory
Well Flow Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
By: Original Certificate Date: f — r ^ 0 3
(Rev. 01,02)
Municipality of Anchorage
• Development Services Department
Building Safety Division `
On -Site Water & Wastewater Program '
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: Ti 2N R3W Sec 15 Lot 64A Parcel ID: 015-05244
A. WELL DATA
Well type PH
Date completed 1973
Total depth 178+ ft.
Date of test
Static water level
If A, B, or C provide PWSID #
Sanitary seal (Y/N) Y
Cased to 40+ ft.
FROM WELL LOG
unknown
Well production —
WATER SAMPLE RESULTS:
ft.
Well Log (YIN) No
Wires properly protected (YIN) Y
Casing height (above ground) 15 in.
AT INSPECTION
10-11-03
148
ft.
g.p.m. 5.65 g.p.m.
Coliform U colonies/100 ml. Nitrate 1.96 mg./l.
10-14-03
Arsenic: NA mg./l. Date of sample: 10-1'-0'
B. SEPTICIHOLDING TANK DATA
Tank Type/Material steel
Tank size 1250 gal. Number of Compartments 2
Foundation cleanout (Y/N) DCO Depression over tank (Y/N) n
Other bacteria 0 colonies/100 ml.
Collected by: Watkins Engr
Date installed 10/25/03
Cleanouts (Y/N) Y
High water alarm (YIN) NA
Date of pumping NA - new Pumper NA
C. ABSORPTION FIELD DATA
Date installed 10/31/83 Soil rating (g.p.d.e or ttz/bdrm) 150 System type deep trench
Length 50 ft. Width 3 ft. Gravel below pipe �5� 5 ft.
Total depth 11.1 ft. Eff. absorption area 650 ftZ Monitoring tube Y Depression over field N
Date of adequacy test 10-11-03 Results (Pass/Fail) Pass For 3 bedrooms
Fluid depth in absorption field before test28.5 in. Water added800 gal. New depth 66.5 in.
Elapsed Time: 36 min. Final fluid depth 52_5 in. Absorption rate >= 450+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (YIN & type) No If yes, give date -
D. LIFT STATION
'Pump on" level at _ in.
Datum
E. SEPARATION DISTANCES
Size in gallons
"Pump
Cycles tested
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 130
Absorption field on lot 145
Public sewer main NA
Sewer/ septic service line 25+
Manhole/Access (Y/N) _
Hiqh water alarm level at
Meets alarm & circuit
On adjacent lots 130
On adjacent lots 130
Public sewer manhole/cleanout NA
Holding tank 100+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5+ Property line 30+ Absorption field 5+
Water main NA Water service line 25+ Surface water 100+
Welts on adjacent lots 100+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 15+ Building foundation 15+ Water main NA
in.
Water Service line 25+ Surface water 100+ Driveway, parking/vehicle storage 0
Curtain drain None known Wells on adjacent lots 100+
F. COMMENTS Tank IiS PRl fiQliy u011ar driveway. J541-riea irula&d fD P1e✓ekd drivirtja,w,
Well is 10 ft off lot, with ingress/egress agreement (attached). Drainfield is under driveway.
G. ENGINEER'S CERTIFICATION
.i! c 744%4' 114.0
I certify that I have determined through field Inspections and
review of Municipal records that the above systems are in �`
conformance with MOA HAA guidelines in effect on this date. * 4 9 TN -
Engineer's Printed Name Cindy W. Ellis
Date I-4-63 ': CindN Ellis
VCE.1os»
HAA Fee $ Waiver Fee $ _
Date of Payment v� Date of Payment
s
Receipt Number Receipt Number.
(Rev. 12/01)
az
0 3
WO
Oo
,SG'b9l M„Ztb,SOoO N LLQLL N
W
aF M
10'TELE.6 CLEC. EBM7. I >t'
_ — x N
I -O
=Vy1j
I•!�y�F
LL`d O
g �
I y ¢ W W
yN UUO N
I maw a
W W V Q v
mq� .0w1-
=io
I
I
I
\ i o
\ e
/ \ I W N
e O
I
I I I WFI
<
I
m I °� I a w
1'1O
rl
0
I I N
M I I o,NB I m
3 I a l I m
NLn
I > I Z
o+ I I I 3
m I
En I I I \
I � I
WWI aw I
I I y Jc
I 'w'O J
I I .•BE
lOEOV`
° I
"O, I
I � I
I I
--1= ----------I--- _ ,
�4
JI I < SO' B.L.M. PATENT REBERVAT I N ( =-W ••••• ,�
I I I �• �� ` �QJ
•
— t---- is v_ -----------IT -
,L L'S9l 3„00,50,0 5 �()�6�'• ��
•`o
C3V0hl d001 .” 099b' �4pls a.o�o
\ Ovon JO 3003
aW
xm
�a
Z0
a ¢ W p
a W T W
Y x m
N FANOo
g0>Z
.<Za
Vz°�
¢1- Rz
5N.Z'Zzo
z�)-r�
Q > ¢ W
OW
wg0z
m�g,.,
<Wfu
WF, a
0 zo
VWf•V
U .
yTFW,
m g
MCI
zZZ
u 4
�g
3cr
N�
OW
~ N
J �
5m
LL0
wo
Nz
N_
Soo
C�
_m
Ow
Z
O
N
Oz
N J
70
�a
o
LL
Vow
z�z
w.0�
LL
xww
zp
W CEN
H
'mm
oz
z�
W Ill
OOj-
azoN
a LLIQ Y
W0
avow
mOx�