On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number. SW030329 PID Number 051-821-23
of 3
Nome:
JOHN THOMSON
Wastewater System: ■ New 0 Upgrade
Address:
NORTHWOODS CIRCLE * CHUGIAK, AK * 99577
ABSORPTION FIELD
Phone: No. of Bedrooms:
(907) 240-2020 4
to Deep Trench 0 Shallow Trench 0 Bed OMound OOther
LEGAL DESCRIPTION
soD Rating: 0.6 Gpoisv. R
Tad °� from 5.0(MAX) n.
Block: Lot Subdivision:
1 10 GLENN VIEW NORTH
Depth to pipe bottom from original grade:
2.0 (MAX) Ft.
Grovel depth beneath pipe:
2.04/2.0 R
Township: _ Range: _ Section:ril
—
added above original geode:
SEE DWG. R
Gravel length:
2 t. 70 (140 TOTAL) PL
WELL: 0 New 0 Upgrade
Gravel width:
5.0 R
Number of 1110.:
1
[Mona between Ene.:
— R
Classification (Private, AB,C):
UtJ\
Total • • •
R
Cawed To:
n.
Total absorption area:
1000 sa. R
Pipe 'notarial:
D 3034/ F-810
Driller.
Dote Drilled:
Static Woter Lanni:
R
Installer:
DAN GREEN
Dat. stalled:
9/26-29/2003
'field:
CPU
Pump Set At:
R
Casing Height Above Ground:
R
TANK
SEPARATION DISTANCES
■Septic OHolding OS.T.E.P. OOther
To
Septic
Tank
Absorption
Field
Uft
Station
Holding
Tank
Public/Prtvate
Sewer un..
Uonufccfunr.
ANCHORAGE TANK
Copeck, In gallons:
1250
Well
200'+
200'+
—
—
25'+
Natation
NumberNumber of compartments
2
Surface water
100'+
100'+
—
—
—
LIFT STATION
Lot Line
5'+
e5'+
—
—
-
Size M gallons:
Wnuloctur.r:
5 +
10'+
—
—
-
Pump on' level at
Pump off. at:
High water alarm at:
Curtain Drain
Pump Maks el:
Electrical Inspection' pet-famed by.
NONE KNOWN
Remarks: *5' LOT LINE WAIVER REQUESTED.
BENCH MARK
(see evrTActiej
Location and Description:
BOTTOM OF TANK
A..umed Elewtion:
89.95 R,
,vo604�.
.....
o`. '
; *�'.. 4 F'..
j
=
pip ••.
�pOd�'Foresstao°oc7
0400000a
S
\ `,
i . 4 kl
I '� �0
* �0
03rd
(ifess:
O0 95 •' eQO
7 .•• eo
ad
Inspections performed by: AKWWC, INC. Dates: 1st 9/26/2003
2nd 9/26/2003
9/29/2003eff
Development Services Department Approval
Reieed and approved by: Date• /// /o?
( 12/01)
PERMIT NUMBER:
SW030329
AS -BUILT DRAWING
A B C
FCO 25.51 4.02 -
ST1 31.40 20.84 54.42
ST2 39.29 24.04 55.74
DBL1 41.28 25.20 56.26
DBL2 42.72 26.07 56.64
FS 62.21 37.02 55.63
C01 62.49 52.24 82.51
MT1 63.40 52.19 82.03
CO2 - 37.92 28.42
MT2 - 34.51 27.28
CO3 76.20 62.19 89.33
MT3 77.62 62.91 89.47
C04 - 50.13 43.48
MT4 - 46.01 41.49
NEW 1250 GALLON
SEPTIC TANK
THI1
PARCEL ID NUMBER:
051-821-23
5' LOT LINE
WANER REQUESTED
"s\\
��ir \
AS* \
`vim ////
a /
TOBEN SPURKLAND
TEST HOLE
ALTERNATE SITE
•
AI.ASKA WATER & WASTEWATER
•-- --
------ CONSULTANTS,
CONSULTANTS, -^-----
3701 F. TUDOR ROAD. SLATE IOI • ANCHCWACF. A( 99.507 • P.4ONF (907)337.6179 • FAX (907)355-5246
PREPARED FOR:
JOHN THOMSON
PHONE NUMBER:
(907) 240-2020
LEGAL DESCRIPTION:
GLENN VIEW NORTH SUBDIVISION; LOT 10, BLOCK 1
TYPE OF WORK:
AS -BUILT DRAWING OF' SEPTIC SYSTEM UPGRADE
DATE
10/24/2003
DRAWN BY:
A.J.G.
SCALE:
1" = 40'
PAGE NUMBER:
2 OF 3
PERMIT NUMBER:
SW030329
AS -BUILT DRAWING
PARCEL ID NUMBER:
051-821-23
TOP OF TANK AT
INLET - 94.82
iFlNAL GRADE es96.82
INVERT OF BUNG
AT INLET = 94.29
TOP OF TANK AT
OUTLET - 94.82
INVERT OF BUNG AT
OUTLET - 94.04
SOUTHWEST TRENCH
ORIGINAL GRADE -
94.42 (AVC),
AKWWC TH#1
1
FINAL GRADE -
95.60
INSULATION
r FILTER FABRIC
ORIGINAL GRADE -
94.42 (AVC)
�y^^`o;^�,."'`"`•..-may 3,4.4P-••••••411MK-•,-,
5.
/-RELATNE ELEVATION OF
GROUNDWATER - 84.42
RELATNE ELEVATION OF BOTTOM
OF TEST HOLE - 82.60
INVERT OF PIPE
- 93.21 (AVC)
BOTTOM OF TRENCH
- 91.17 (AVG)
10'
NORTHEAST TRENCH
ALASKA WATER & WASTEWATER
-'------^------ CONSULTANTS. INC. -------------
3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE. AK 00507 • PHONE (007)337-6170 • FAX (907)338.3266
ii
7SL
FINAL GRADE -
�- 95.60
INSULATION AKWWC TH,1
FILTER FABRIC -
INVERT OF PIPE
- 93.17 (AVC)
BOTTOM OF TRENCH '— 5 - 91.17 (AVC)
RELATIVE ELEVATION OF
GROUNDWATER - 84.42
RELATIVE ELEVATION OF BOTTOM ---Fib—,4
OF TEST HOLE - 82.60
DATE:
10/24/2003
DRAWN BY:
A.J.G.
SCALE
1" = 40'
PREPARED FOR:
JOHN THOMSON
PHONE NUMBER:
(907) 240-2020
PAGE NUMBER:
2 OF 3
LEGAL DESCRIPTION:
GLENN VIEW NORTH SUBDIVISION; LOT 10, BLOCK 1
TYPE OF WORK:
AS -BUILT DRAWING OF SEPTIC SYSTEM UPGRADE
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650 Anchorage, AK 99519-6650
www. c i. an c h o rag e. ak. u s
(907) 343-7904
Waiver Review Worksheet
WR#: 040041 PID#:051-821-23 HA#: 040279 Permit#:
Date Received: 6/22/04
Legal Description: Glenn View North Block 1 Lot 10
Engineer: Garness Engineering Group, Ltd.
3701 E Tudor
Applicant: John Thomson
Waiver Requested: 5 feet from Absorption Field to Property Line
Criteria:
Geology
A. Water Table
B. Soil Sorption
C. Permeability
D. Water Table Gradient
E. Horizontal Separation
Total:
Points:
Waiver is Granted:
List Conditions or Reasons for above:
Waiver is not Granted:
Date: 6 - 2. 2. - D Lt
By:
T a • "of Reviewer
Rec#: 43926 Amount: $150.00 Date Paid: 6/22/2004
Mayor Mark Bcgich
Municipality of Anchorage
P.O. Box 116650 • Anchorage, Alaska 99519-C)650 • Telephone (907) 343-8301 • Fax (907) 343-8200
4700 Bragaw Street • Anchorage, Alaska 00507
�t�t��.nunti.org .
Building Safety Division
6/2/2004
Garness Engineering Group, Ltd.
3701 E Tudor Road
Anchorage, AK 99504
Subject: Waiver Request for Glenn View Estates North Block 1 Lot 10
Waiver Request #WR040041
Parcel ID #051-821-23
Dear Mr. Garness:
Your request for a waiver of the required 10 feet from the Absorption Field to the
Property Line. The approved separation distance is 5 feet.
This waiver approval applies to the existing Absorption Field to Property Line
separations only. Any future upgrade to the on-site wastewater disposal system will
require all separation distances be met or another approval from this department.
If there are any further concerns or questions regarding this waiver, please call our office
at 343-7904.
Sincerely,
Jeff Poet
Engineering Tech
On -Site Water & Wastewater Program
Community, Security, Prosperity
ALASKA WATER & WASTEWATER
, .. « u .. CONSULTANTS, INC. 111*.4*64»4...416.40k 1.g,ar,.444644at..®..661.
October 28, 2003
Municipality of Anchorage
Development Service Department
Building Safety Division
On -Site Water & Wastewater Program
P.O. Box 196650
Anchorage, Alaska 99519-6650
Ref: Lot Line Waiver for Lot 10, Block 1; Glenn View North Subdivision.
To whom it may concern:
We request that your department issue a 5 foot lot line waiver from the northeast property line to
the existing drainfield. I am unaware of any adverse impacts this waiver would have on adjacent
wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you
for your assist , e.
ince e
effe'�
Presi i'c
P.E., M.S.
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Permit Number: SW030329
Legal Description: Glenn View Estates North Block 1 Lot 10
Design Engineer: 0041 AK Water & Wastewater Consultant
Owner Name: John Thomson
Owner Address: 17343 Santa Maria
Eagle River , AK 99577 -
Date Issued: Aug 25, 2003
Expiration Date: Aug 24, 2004
Parcel ID: 051-821-23
Site Address: Unknown
Lot Size: 42629 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 (24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
1 L
Received By: - —. r ttraf'I7a /► Date* 8.25 '03
Issued By Date: 2 tzslos
Parcel I.D. /
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
82/— 23
Permit Number
Property owner(s) JOHN THOMSON Day phone 240-2920
Mailing address (1) 17343 SANTA MARIA * EAGLE RIVER
Mailing address (2) A/ HA/ NORTNai000s C/RCL f Zip Code 99577
GLEAM/ Errr►ris A/o►erlf
Legal description (Lot, Block & Sub'd.) LOT 10. BLOCK 1: Jelt.fibikile SUBDIVISION
Legal description (Section, Township & Range) N/A
Lot Size 14 oS t tf' as Acres/Sq.Ft. Number of Bedrooms 4
THIS APPLICATION IS FOR:
Sewer Only II Well Only 0
Sewer and Well 0 Water Storage 0
Sewer Upgrade 0
THIS PROPERTY CONTAINS:
Hot Tub 0 Jacuzzi
Swimming Pool 0 Water Softening Unit
Therapy Pool 0
❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal codes.
ALASKA WATER & WASTEWATER CONSULTANTS, INC.
Permit Fees: 400
Waiver Fees4 /SD.
Date of Payment: g-15 --05 Date of Payment:
Receipt Number: Li 02.05 (3-5-
Receipt Number: r 9Z(' r /.
ALASKA WATER & WASTEWATER
arnnmaua+ais®a.aalemoseaarwamrnm CONSULTANTS, 1 N C. easaearalliCmsaMieaai co11111.r
August 18, 2003
Municipality of Anchorage
Development Service Department
Building Safety Division
On -Site Water & Wastewater Program
P.O. Box 196650
Anchorage, Alaska 99519-6650
Ref: Proposed Septic System for Lot 10, Block 1; Glenview North Subdivision
To whom it may concern:
The proposed 4 bedroom house will be served by a community water system and a private septic
system. A test hole was excavated on the property by Toben Spurkland P.E. and by our firm.
The primary drainfield will be designed around the 30 foot radius of our test hole. We are
proposing that a 1250 gallon septic tank and dual 5 -wide type drainfields be installed. Comments
regarding the design are summarized as follows:
1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring,
and the percolation test results.
2. TRENCH DESIGN:
a. Percolation Rate: 18 & 20 minutes/inch
b. Proposed Application Rate: 0.6 gallons/day/ft2
c. Number of Bedrooms: 4
d. Design Flow: 600 gallons per day
e. Minimum Absorption Area: 1000 f12
f. Total Depth: 4 feet (max.)
g. Effective Depth: 2
h. Width: 5 feet
i. Reduction Factor: 0.7
j. Minimum Length: 2 @ 70 feet long each (140 feet total length)
k Effective absorption area = 1000 f12
3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic
system.
4. TOPOGRAPHY: The area for the proposed drainfields is fairly flat. In short, there are no
slope concerns.
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com
We are unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact us at 337-6179. Thank you for your
assistance.
S'scerel
Jeffr=y ',. amess,
Pres'
.E., M.S.
NOTE: A site plan drawing, a design drawing, a detail drawing, a soils logs, and a 7 page
construction specification letter which are all part of the design package for this septic system.
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com
NOTE: ALL PROPERTIES SHOWN
ARE TO BE SERVED BY PUBLIC
WATER AND PRIVATE SEPTICS
0'
WI
PROPOSED SEPTIC SYSTEM
(SEE DESIGN PAGE 2 OF 2)
PROPOSED 4
GLENN VIEW NORTH S/D: BEDROOM
LOT 12. BLOCK 1, HOUSE
ALTERNATE SrTE
TOBEN SPURKLAND
TEST HOLE
•
•
•
•
ALASKA WATER & WASTEWATER
CONSULTANTS, INC.
3701 E. TUDOR ROAD. SUITE 101 • ANCHORAGE. AX 99507 • PHONE (907)337.6179 • FAX (007)358-3246
PREPARED FOR
JOHN THOMSON
DATE:
8/13/2003
DRAWN BY:
C.J.G./B.S.G.
SCALE:
1" = 100'
PHONE NUMBER: PAGE NUMBER:
240-2020 1 OF 2
LEGAL DESCRIPTION:
LOT 10, BLOCK 1; GLENVIEW NORTH SUBDIVISION
TYPE OF WORK:
SITE PLAN FOR PROPOSED SEPTIC SYSTEM
+tii
"i
61
�A
..4
e A. Gar ess; t�
+14Pf•L —79 • e�Q
. 1 Ftp•+
IV";
kra` P,rofessl000y
NOTE: THE WATER UNE
MUST BE 10+ FEET
FROM THE PRIMARY AND
ALTERNATE SITE.
NOTE: THE CONTRACTOR SHALL HAVE THE
NORTHEAST LOT UNE AND THE EAST LOT
LINE FLAGGED BY A REGISTERED LAND
SURVEYOR PRIOR TO CONSTRUCTION.
NEW 1250 GALLON
SEPTIC TANK
INSTALL FOUNDATION
CLEANOUT
TOREN SPURKLAND
TEST HOLE
ALTERNATE SITE WILL
REQUIRE THE USE OF
AN ADVANTEX
TREATMENT SYSTEM
ALASKA WATER & WASTEWATER
WATER UNE
KEY BOX
N
DATE:
8/13/2003
INSTALL DOUBLE
CLEANOUTS
INSTALL FLOW
SPLITTER
PROPOSED DRAINFIELDS. EXCAVATE
TWO DRAINFIELDS THAT ARE 4 FEET
DEEP MAXIMUM AT ANY POINT BY 5
FEET WIDE BY 70 FEET LONG EACH
(140 FEET TOTAL LENGTH). ADD 2
FEET OF CLEAN. WASHED SEWER
DRAINROCK.
DRAWN BY:
C.J.G./B.S.G.
--------��--•--•-- CONSULTANTS, INC.
3701 E. TUDOR ROAD. SUITE 101 • ANCHORAGE. AK 99507 • PHONE (907)337-6179 • FAX (907)338-3746
PREPARED FOR:
PHONE NUMBER:
JOHN THOMSON 240-2020
SCALE:
1" = 40'
PAGE NUMBER:
2 OF 2
LEGAL DESCRIPTION:
LOT 10, BLOCK 1; GLENNVIEW NORTH SUBDIVISION
TYPE OF WORK:
DESIGN OF PROPOSED SEPTIC SYSTEM
ALASKA WATER & WASTEWATER
�----- CONSULTANTS, INC. -
3701 E. TUDOR ROAD. SURE 101 • ANCHORAGE. AC. 99507 • PHONE (907)337-6179 • FAX: (907)338-3248 • WEBSRE: okwwc.com .....'
44
ISOIL LOG - PERCOLATION TEST
LEGAL DESCRIPTION' CLENVIEW NORTH SUBDIVISION; LOT 10, BLOCK 1
PERFORMED FOR: JOHN THOMSON DATE: 8/4/2003
B.O. 1.
15-
5-
16-
16-
17-
17-
18-
18-
19-
19-
20
20
SOILS LOGGED BY:
COMMENTS'
PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS yy P RFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: g3 !303 1
TEST HOLE #1
SOIL CLASSIFICATIONS
feNSI
11:111!11
00
000 0
RERRO
anta
GW ORG
GP
GM
GC
SW
SF'
SM
SC
ML
CL
OL
MH
CH
OH
DEPTH TO
GROUNDWATER
DATE
DRY
8/4/2003
10.5'
8/6/2003
(0 .0'
8/13/2003
12:18
-
1
7953 eve
Q°d/'rof •• 1D�°0
�ODoo s
THft
TOKEN SPURKLAND
TEST HOLE
SITE PLAN
1"-100'
DATE
READING
CLOCK
TIME
NET TIME
(MINUTES)
WATER LEVEL
READING
NET DROP
(INCHES)
8/6/2003
1
12:18
-
6"
-
2
12:48
30
4.5"
1.5"
3
12:48
-
6"
-
4
1:18
30
4.5"
1.5"
5
1:18
-
6"
-
6
1:48
30
4.5"
1.5"
PERCOLATION RATE
20 (MIN./INCH)
TEST RUN BETWEEN 4.0 FT. AND
A FOUR HOUR PRESOAK WAS PERFORMED:
JODY MAUS
PERC. HOLE DIA. 6 (INCHES)
4.5 FT.
U YES ❑ NO
PERCOLATION TEST PERFORMED BY: JODY MAUS
Performed Fcr.
Legal Description:
Dear,
(Feet)
1-
2-
3 --
6-
7
8 -
11
12-
13
14-
15-
16-
17-
18-
19•
20.
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw SL
P.O. Box 196650 Anchorage, AK 99519.6650
www. ei,anchorage.ak,og
(907)343.7904
Soils Log - Percolation Test
L>=1'V1=N,Vz NOIZ11-1 skj
'(ENGINEER'S SEAL)
Date Performed:
LOT D t,. Fjk I Township. Range. Section:
1( olz.E7A14tc,5
SaicLy S:«'•u, I a. tel
M L.
S& -holy S;(4- G ray
ML
SfiKc\y S t i 4
1ZOL12S
COMMENTS
S eTro 11-4 O c•
1-} o LE
Slope
WAS GROUND WATER
ENCOUNTERED?
IF YES. AT WHAT DEPTH?
Depth to Water Aher
Monitoring?
1O
s
L
0
v
E
• Site Plan
•
1 1 1
et
et
(.12 toes .4Zo ® ggt
Date:
Reading
Date
Gross Time
f� r.--
Net Time
•v• V
Depth to Water
(f LOGS
Net Orco
FILL
CZESoAX-
'''
t117-102.
1Z:sS
--
5/�.
t : E6
b04,:11
qtly
75�/
176
it/ I
02!/H
I 78
b/Z
2..:35
t4o
Era
3:05
3o
( Iesnn nl FERC HOLE 0 AMETER
TEST RUN BETWEEN 3 FT AND 14 FT
PERFORMED 8Y: 1 , s 1 i. S CERTIFY THAT THIS TEST W.:.S
PERFOR\IED IN ACCORDANCE WITH ALL STATE ANO MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: Il2I io Z
Parcel I.D.
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage. AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
n5i- 8ai-��
1. GENERAL INFORMATION
COSA# v00Qq/9--
Expiration Date: '7' — / / — Q 9
Complete legal description GLENN VIEW ESTATES NORTH, BLOCK 1, LOT 10
Location (site address) 23401 NORTHWOODS CIRCLE • CHUGIAK, AK 99567
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
JEFFREY SPITLER Day phone
688-0818
23401 NORTHWOODS CIRCLE * CHUGIAK, AK 99567
Day phone
Day phone
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 4
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank
Community On-site
Public Sewer
•
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given In paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that
Guidelines for this application,
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm
GARNESS ENGINEERING GROUP. Ltd. Phone 337-6179
Address
3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date
Engineer's Comments:
In conducting this evaluation, GEG, LtD. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily Identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the solo benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party Is not authorized, nor will it confer any legal right whatsoever.
5. DSD SIGNATURE
Approved for
Disapproved.
Conditional approval for
bedrooms.
\\4
�SQ0oh
ness• QO
C —7953 •. `FOS
SJA 9.
v
IIDdpro(easlo��q
�40t04 t•tI((lrrrr,rr
��\ o •. o
Jam• ON-SITE ��i?
: WATER AND : m^=
WASTEWATER :
- •PROGRAM
O ••
�_��
bedrooms, with the flowing stipulations:
I tSEN 111\
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
By:
(Rev. 11/05)
7
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Reort
Other
Original Certificate Date:
I-1-11-08
CERTIF
Legal Description:
A. WELL DATA
Well type
Date completed
Tota
Date of test
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
ICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
GLENN VIEW ESTATES NORTH, LOT 10, BLOCK 1
PUBLIC WATER
Parcel ID: 0 6'/-$z( - 23
If A, 8, or C provide PWSIDtt _ Well
Sanita se
Cased to ft.
FROM WELL LOG
Static water level
Well production
WATER SAMPLE RESULTS:
Coliform colonies/100 ml.
A
ft.
gpm
Nitrate m•./L
Wires properly protected (Y/N)
Casing height (above ground)
AT INSPECTION
Date of sample'
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material SEPTIC/STEEL
in.
herbar
rta colonies/100 ml.
Collected by
Date installed 9/26-29/03
Tank size 1250 gal. Number of Compartments E Cleanouts (YIN) YES
Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO
Date of pumping 4/1/2008 Pumper
C. ABSORPTION FIELD DATA
Date installed 9/26-29/03
Soil rating
Length 140 (2 0 70) t, Width
High water alarm (Y/N)
JR'S PUMPING
N/A
(BELOW EXISTING GRADEI
System type
5 ft. Gravel below pipe 2.04/2.0 ft.
TRENCH
Total depth 4.8-5.5 ft. Eff. absorption area 1000 ft'
Monitoring tube YES
Depression over field NO
Date of adequacy test •'4/2/2008 Results (Pass/Fail) PASS For 4 bedrooms
Fluid depth in absorption field before test 5/6 in Water added 910 gal. New depth 11/9 in.
Elapsed Time: 320 min. Final fluid depthB/10in, Absorption rate >= 600+
P g.p d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date
**INTRODUCED WATER THROUGH DOUBLE CLEAN OUTS AFTER SEPTIC TANK
D. LIFT STATION
Date installed Size in gallons Manhole/Access (Y/N
"Pump on" level at in. "Pump off' level • High water alarm level at in
Datu Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot
Absorption field on lot
Public sewer main
Sewer /septic service
containment areas
PUBLIC WATER
On adjacent Tots
On adjacen
Public sewer manhole/cleanout
Holding tank
Manure/animal excrete storage areas
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation
5'+ Property line
5'+
Absorption field
Surface water
Water main 10'+ Water service line 10'+
Wells on adjacent lots 200'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line
*5'
Water service line
Building foundation 10'+
10'+ Surface water 100'+
Curtain drain NONE KNOWN
F. COMMEND WAVIER# 040041
G. ENGINEER'S CERTIFICATION
Wells on adjacent lots 200'+
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this
date.
Engineer's Print d N me
c}�c�o6
Date
JEFFREY A. GARNESS
Water main
'5'+
100'+
10'+
Driveway, parking/vehicle storage
10'+
• 0000
VA
ass: 0
' C -77 3 •' „�FO�
cv
1�ec;Pro fesonce'
�040000�
COSA Fee $ y 5f1-
,../
Date of Payment / / V 08
Receipt Number 13(.0i9-1
(Rev. 11/05)
Waiver Fee $
Date of Payment
Receipt Number
ASBUILT
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
FOLLOWING DESCRIBED PROPERTY:
AND THAT NO ENCROACHMENTS EXIST EXCEPT AS
INDICATED. IT IS THE RESPONSIBILITY OF THE
OWNER TO DETERMINE THE EXISTENCE OF ANY
EASEMENTS, COVENANTS, OR RESTRICTIONS
WHICH DO NOT APPEAR ON THE RECORDED SUBDI-
VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD
ANY DATA HEREON BE USED FOR CONSTRUCTION
OF FENCE LINES, OR FOR ESTABLISHING BOUND-
ARY LINES.
SEWARD & ASSOCIATES LAND SURVEYING 694-082Q
SCALE: ,
SO
DATE]
3/ee9'
GRID:
HG1iS6°
FR:
VW -yam
DRAWN:
aef
r''%P�� OFy/A•••• r5' e.
•
i;= '• TM'GV'' 7 •
•
.y
•
Diane Mark Sawed
�,•.
LS -6918
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 051-821-23
1. GENERAL INFORMATION
Complete legal description
HAA#
70 /A 04
d lf o a-79
Expiration Date: 6 -
GLENN VIEW NORTH S/D; BLOCK 1, LOT
10
Location (site address or directions)
NHN NORTHWOODS' CIRCLE
Current Property owners) JOHN THOMSON Day phone 240-2020
Mailing address 17343 SANTA MARIA * EAGLE RIVER, AK 99577
Lending agency
Mailing address
Real Estate Agent
Mailing address
Day phone
Day phone
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
•
4
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank
Community On-site
Public Sewer
•
0
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid
water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water
system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's
work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my
investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd.
Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
In conducting this evaluation, GEG, Ltd. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations..The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the yearand.the.water.usage of the .family.being.served by_the.system..__
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, Ltd. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
5. DSD SIGNATURE
Approved for T bedrooms.
Disapproved.
Conditional approval for
Phone 337-6179
Date 513/4_
bedrooms, with the fllowing stipulations:
ll<<t tYfl(aOF((((/�rr�i
AY:. • • ',61srf?.
Jam: •
ON-SITE
; WATER AND : rn
• WASTEWATER :
PROGRAM
�• ;.
•
JJJJJ/c9' tie I SE\01" -•'.
») ».
Attachments:
HAA Checklist
Septic System Advisory
Well Flow Advisory
By:
Manitenance Agreements
Supplemental Engineer's Reort
"Other
(Rev. 12!01)
Original Certificate Date: - 2_ O T
r
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
HEALTH AUTHORITY APPROVAL CHECKLIST
. Legal Description: GLENN VIEW NORTH S/D; BLOCK 1, ' LOT 10 'Parcel ID: 051-821-23
y
A..WELLDATA ..
i .
Well type PUBLIC If A, B, or C provide,PWSID# Welll Log (Y/N)
. i
Date completed Sanitary seal (Y/N) ' Wires properly protecte• /N)
. ' ',:: , • i , i
•
Total depth i ft. • I Cased to ft. Casing hei• • above ground) in
FROM WELL LOG .-rF9. NSPECTION
Date of test
Static water level
.1.
Well,production g.p.m.
WATER SAMPLE RE S:
,Colifomi . r ml. Nitrate mg./L.
he ft.
g.p.m.
-- Other bacteria colonies/100 ml.
enic:. mg./L. Date of sample: Collected by:
B. SEPTIC/HOLDING TANK DATA
! { i ,t
Tank Type/Material STEEL Date installed
llled 9/29/2003 ,
Tank
�� Size 1250
gal. Number of Compartments • .....2..... : Cleanouts(Y/N) YES
Foundation cleanout (Y/N) YES Depression over tank(YIN) NO , High wateralarm (YIN) N/A
Dateof pumping NEW Pumper —
C. ABSORPTION FIELD DATA
Date installed 9/29/2003
Length' i.140 (2070) ft
Soil rating
Width
•BELOW FINAL GRADE
r ft2/bdrm) 0.6 .
5 ft.
Total ,depth 4.43 ft Eff. absorption area 1000 ft2 Monitoring tube
Date of adequacy test NEW Results (Pass/Fail) PASS
System type SHALLOW TRENCH
Gravel below pipe 2.0+ ft.
i '
YES Depression over field NO
!1 4
For 4 bedrooms
Fluid depth in absorption field before test in Water added •01.`1 t
! i. i NEW '11 i
Elapsed Time: min. Final fluid de.' • Absorption rate >_
An r - - a ment (past 12 mo.) (Y/N & type) :,If yes, give date
D. LIFT STATION
Date installed Size in gallons Manhole/Ac
"Pump on" level at in "Pump off" - in High water alarm level at 'in.
Datu Cycles tested
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot
Absorption field on lot L,r WATER 0
Public sewer main PUB Public sewer manhole/cleanout
Meets alarm & circuit requirements?
On adjacent Tots
ots
S
c service line Holding tank
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field 5'+
Water main 101+ Water service line 10'+ Surface water 100'+
Wells on adjacent Tots N/A
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line *5' Building foundation 10'+ Water main 1 0'+
Water service Zine 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+
Curtain drain . NONE KNOWN
Wells on adjacent Tots N/A
F. COMMENTS . .. _
*WAIVER REQUESTED WITH INSPECTION REPORT
G. ENGINEER'S CERTIFICATION
1 certify that 1 have determined through field inspections and
review of Municipal records that the above systems are in •
conformance with MOA HAA guidelines in effect on this date.
Engineer's Printed ame
Date 5113 0¢
JEFFREY A. GARNESS
vO
•
D
ness:
3 \c°.OD
„Profession o`er
DO000��
HAAFee$ 4'
Date of Payment fa //'/04
Receipt Number 01.573-7
(Rev. 12/01)
Waiver Fee $
Date of Payment .
Receipt Number
ASBUILT
• 'SEWARD & ASSOCIATES
I HEREBY CERTIFY •THAT I HAVE SURVEYED THE
FOLLOWING DESCRIBED PROPERTY:
G�iV4,17 Esr79,Z3 o. 7, 1; - oT/e, oe/:'
AND THAT NO ENCROACHMENTS EXIST EXCEPT AS
INDICATED. IT IS THE RESPONSIBILITY OF THE
OWNER TO DETERMINE THE EXISTENCE OF ANY
EASEMENTS, COVENANTS, OR RESTRICTIONS
WHICH DO NOT APPEAR ON THE RECORDED SUBDI-
VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD
ANY DATA HEREON BE USED FOR CONSTRUCTION
OF FENCE LINES, OR FOR ESTABLISHING BOUND-
ARY LINES.
SCALE:
-DATE=
GRID:
,t/Q), 5C'
FB: /o/
DRAWN:
LAND SURVEYING 694-082
4.7771""4
•.s
. Duane Mark Seward • /
I1.r• LS - 6918 •'•
_.... •• '•SJ.r