ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. O51
Property owner(s)
Mailing address ~
Site address --
Day phone
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section)
Lot Size Sq. Ft. Number of Bedrooms
THIS APPLICATION
([~] all that apply)
Absorption Field []
Septic Tank ~'
Holding Tank []
Privy []
Private Well []
IS FOR:
THIS APPLICATION IS AN:
Initial []
Upgrade g~
Renewal []
Water Storage []
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of"property owner or authorized agent)
Permit/Rush Fees: ,~k...-~.?- ./~¢_~2to.c_~¥-E~.-¥Waiver Fees:
Date of Payment: ~\;~-(:k.~, \~, Date of Payment:
Receipt Number: (_?-~ ,~.~,-'~ ~ {',~ Receipt Number:
Permit No. E?~)¢ \~,k,~--'l,''~°'- Waiver No.
G:\Building\On Site\Forms\Client Forms\Permit App_010411 .doc (Rev. 1/11 )
Slourt land Engineering
Environmental Consulting and Design
Municipality of Anchorage
Development Services Department
Building Services Division
On-site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, AK 99519-6650
I
September l 5, 2011
Subject:
SEPTIC TANK PERMIT APPLICATION
Thunder Bird Heights #1 Block 4 Lot 32
Ladies and Gentlemen:
We are submitting an application to replace the septic tank for this lot. The existing septic tank is 30 years
old and the home owner would like to replace it. The submittal consists of one (1) drawing showing the
present improvements on the lot and the proposed improvements of the lot, of which only the septic tank
is subject to this permit application.
There are no wells within one hundred feet of the proposed replacement site. The installation of this
septic tank will not prevent wells and septic systems from being installed on the adjacent lots. There are
no developed or natural surface / sub surface drainage courses within 100 feet of the proposed septic tank
location. The proposed septic tank will not change the general slope of the area. Ponding and/or
concentration of surface runoffwill not result from this installation.
If you have any questions or are in need of additional information please contact me at 279-3916.
Sincerelw
Lars Spu~kland, P.E.
203 West 15th Avenue Suite 202, Anchorage, AK 99501, Phone: (907) 279-3916
Fax: (907) 276-6013, SpurklandEng~gci. net
LITT~8
NOTE: THUNDER BIRD HEIGHTS IS SERVED BY ,4 CLASS A
PUBLIC WATER SYSTEI~.
25 8 25 58 75 180 125
SCALE'. ~ ~ 50 FT.
NOTE: TI'IlS IS NOT A SURVEYED PLAT. WELL ~ SEPTIC
LOCATIONS TAKEN /'ROM ON-SITE WATER AND WASTE WATER
OEPART/I~ENT OOCUI~ENTATION. All LOCATIONS SHOWN ARE
APPROXIMATE.
DIIUBLE j 4 FEET CITVER
CLEANDUTS ~ /
= ,i.E/-~_.=
EXISTING LINE
BENCH tJARK XXXXXXXXXXX
ASSUMED ELEVATION I00'
FI7UN~gA TIITN
CLEANITUT
SPURKLAND ENGINEERING
203 W 15TH. AVENUE
ANCU. AK. 9950~
(907,) 279-3916
THUNDERBIRD HEIGHTS Jl BLK 4 LT 33
LARRY FRICK
27908 RAVEN CT., CHUG/AK, AK 99567
SEPTIC SYSTEM DESIGN
DATE: SEPT. 15, 2011
SHEET: I/I GRID: NW1865
PERMIT # £$P]]]XXX PID # 05]-582-£3 T~gH#]B2L 32.DP/G
~"~",~ MUNICIPALITY OF ANCHORAGE' ~
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME PHONE
DISTANCE TO:
~ ~ Material No. of compartments
~ Z Manufacturer
~ ~ Inside length Width Liquid depth
Liq. capacity in gallons
t~ IF HOME'DE:
Well Dwelling PERMIT NO.
~ ~ DISTANCE TO:
O Z ~ Manufacturer Material Liquid capacity in gallons
~ Well ~ Foundation Nearest lot line PERMIT NO.
J
DISTANCE
TO:
~ ~ ~ No. of lines Length of each line Total length of lines Trench width Distance
~t~en
lines
~ Z ~ inches
~ Top of tile to finish grade Material beneath tile Total effective absorption area
inches
Length W~dth Depth PERMIT NO.
~ ~ Type of crib Crib diameter Crib depth Total effecti~ absorption area
~ Well Building foundation Nearest lot line
m DISTANCE TO:
Driller Distance to lot line PERMIT NO.
~ Class Depth
m Building foundation Sewer line Septic tank Absorption area(s)
~ DISTANCE TO:
DATE LEGAL
72-013 IRev. 3/78)
PERM'Z'T NO.
Of4--S I TE
( 810706 )
APPLICANT
LOCATIOH
LEGRL
MLIr-.I I C I P_RL I T~" Oh Rf4OH~,RRGE
DEPRRTMEHT~HERLTH RND ENVIROHMENTRL , ~OTECTION
825 "L' STREET~ RNCHORRGE, RI<. 9950&
264-4720
~EL4EF2 PER£.I I T
TYPE OF SOIL RBSORPTION SYSTEM IS: TREHCH
MRXIMUM NIJMBER OF BEDROOMS = j? SOIL RRTING (S~] FT/BR)= 85
THE REQUIRED SIZE OF THE SOIL RBSORPTION SYSTEM IS:
DEPTH= 9 LEI"4GTH= RR'-.."EL DEPTH= 6
THE LENGTH DIMENSION IS THE LEHGTH (IN FEET) OF THE TRENCH OR DRRINFIELD.
THE DEPTH OF ~ TRENCH OR PIT IS THE DISTRNCE BETNEEH THE SURFROE OF THE
GROUND RND THE BOTTOM OF THE E~CR'¢RTIOH (IH FEET).
THERE IS NO SET ;4IDTH FOR TREHCHES.
THE 6RR'¢EL DEPTH IS THE MIHIMUM DEPTH OF 6RRVEL BETNEEN THE OUTFRLL PIPE
RND THE BOTTOM OF THE EXCRVRTION (IN FEET). ~ ~
NUMBER OF RESIDEHCES THRT THE WELL WILL SERVE.
TklO ( 2 ) I t4SPECT I FJf4S ARE RESLI I RED
BRCKFILLING OF RN9 SVSTEM WITHOUT FINRL INSPECTION RND RPPROVRL BY THIS
DEPRRTMENT NILL BE SUBJECT TO PROSECUTIOH.
MINIMUM DISTRNCE BETWEEN R NELL RND RN9 ON-SITE SENRGE DISPOSRL SgSTEM IS
%88 FEET FOR R PRIVRTE NELL OR &58 TO 288 FEET FROM R PUBLIC HELL DEPEHDING
UPON THE TYPE OF PUBLIC HELL.
MINIMUM DISTRNCE FROM R PRIVRTE NELL TO R PRIVRTE SEWER LINE IS 25 FEET RND
TO R COMMUNITY SENER LINE IS 75 FEET.
OTHER REQUIREMENTS f'lR'¢ RPPL9. SPECIFICRTIONS RND CONSTRUCTION DIRGRRt'IS RRE
RVRILRBLE TO IHSURE PROPER INSTRLLRTION.
PERM I T F>~P I ~:FS DFCFr4BFR 3~,. fl 982
I CERTIFb' THRT
%: I RM FRMILIBR I,IITH THE REQUIREMEHTS FOR ON-SITE SEI,IERS RND WELLS RS SET
FORTH BM THE MUNICIPRLIT9 OF RNCHORRGE.
2: I NILL INSTRLL THE 5VSTEf'I IN RCCORDRNCE NITH THE CODES.
~: I UNDERSTRND THRT THE ON-SITE SENER SVSTEM MRV'REQUIRE EHLRRGEMEHT IF THE
RESIDEHCE IS REMODELED TO I~.~CLUDE MORE THRN g BEDROOMS.
RP~ICRNT NILBUR DITTBRENDER
WILBUR DITTBRENDER
RRVEN LOOP
L~2 B4 THUNDERBIRD HTS
SR2 BOX412 E.R,
LOT SIZE
20000 S~.URRE FEET
PERFORMED FOR:
LEGAL DESCRIPTION: '
2
3
4
5
6
7
8
· MUNICIPALITY OF ANCHORAGE
~SOIL$ LOG - PERCOLATION TEST
SLOPE
WAS·GROUND WATER ' S
L
ENCOUNTERED? O
P
DEPTH?
Gross Nat O~pth to - Net .
Reading Data Time '. Time Water : Drop
PERCOLATION RATE (mlnute~linch)
TEST RUN BETWEEN , FT AND , FT
14
15
16
17
18
'19-
2O
COM'~ENTS
72-008
APPLIC"- T FILLS OUT UPPER HAI/'",ONLY
Phone
Property Oven,er ~~/
Buyer
Zip Code
Address
,* ' ' Phone
Zip Code
kddress
Ty~e ~f Rest~nce
~Slngle Family Bedroo~
~ Multiple Family ~ No. of
~ Other '
Water Supply
~ ~ndlvld~l ~ ~ A~ACH ~LL LOG. A w~l log Is required for'all wells drl~ed since June 1975.
' ~Communlty For wells ~llled prior to that date, give well depth (attach log If available).
~ Public Utility
Sewer Disposal
Year IndivMual Installed:
pndivldl ~ When Connected to Public Ufillt~ - ~ ~/~ -
ublic ~llity
~ Holding Tank
.... NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSING CAN BE INITIATED.
Time Time Time Time
Date Date
Inspector Inspector Inspector Inspector
~ ~O' MUNICIP~LI~ OF AN~O~GE
~NVI~ONM~NTAL PgOTECTION
SEP
g c i. VEP.
(~) APPROVED BEDROOMS '~ON~ITIONS OF APPROVAL
( ) DISAP~OVED
( ) OONDIT~NAL APPROVAL'
~oll~ Ra~lng ~ D~we~ lnstalle~ WeU To ~sorption A~ea Wel~ Log Received
~--J~' ~ Well to Tank Septic T~k Size
DATE RECEIVED
INSPECTION APPOINTMENTS
TIME TIME TIME
DATE DATE DATE
MUNICIPALITY OF ANCHORAGE
(.~ DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECT~OL~NICiPALiTy OF ANCHORAGE
: 825 LStraet-Anchorage, Alaska 99501 ' DEPT. OF H~LTil &
E~IRONMENTAL P~:OT~ION
ENVIRONMENTAL SANITATION DIVISION
Telephone 2644720 OCT ~ g 1981
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
PFFFI~/C~
DIRECTIONS: Complete all parts o, page 1. Incomplete requ~ will not be preened. Please allow ten (10) days for processing.
t' P O
PROP~TYRESIDENTIIf~ifferen~ma~ve) ~ j PHONE
~. BUYER /~ I , ~ ~ PHONE
· .
MA~L~NG ADDreSS
ADDRESS
· · / /
4. REALTOR/AGENT ~~/ ~, ~~ J PHONE
5. LEGAL DESCRIPTION - /) ~ --
6. TYPE OF RESIDENCE ·
{~ SINGLE FAMILY
F'I MULTIPLE FAMILY
7, WATER SUPPLY
i--I INDIVIDUAL'
[~ COMMUNITY
[] PUBLIC UTI LITY
NUMBER OF~BEDROOMS
r-I One [] Four
[] Two [] Five
C~""Th ree [] Six
[] Other~
* ATTACH WELL LOG. A well log is required for all wells drilled
since June 1975. For wells drilled prior to that date, give well
depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
~ INDIVIDUAL/ON-SITE**
[] PUBLIC UTILITY
YEAR ON-SITE SYSTEM WAS INSTALLED.
\.,~A '~-~ -~\
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010 (Rev. 6/79)
~ THIS SIDE FOR OFFICIAL USE ONLY :
1. TYPE OF RESIDENCE
[] SINGLE FAMILY
I-'1 MULTIPLE FAMILY
NUMBER OF BEDROOMS
[] ONE [] THREE [] FIVE
[] TWO [] FOUR [] SiX
[] OTHER
2. WATER SUPPLY
[] INDIVIDUAL
[] COMMUNITY
[] PUBLIC UTILITY
Connection Verified
3. SEWAGE DISPOSAL SYSTEM
[] INDIVIDUAL/ON -SITE
[]PUBLIC UTILITY
Connection Verified
PERMIT NUMBER
DEPTH OF WELL
DATE DRILLED
LOG RECEIVED
PERMIT NUMBER
.. DATE INSTALLED
INSTALLER
[]Septic Tank or I--IHolding Tank
Size: If Tank is homemade
give dimensions:
TYPE OF TANK
TOTAL ABSORPTION AREA
4. DISTANCES
WELL TO:
SOILS RATING
MANUFACTURER
MATERIAL
Absorption Area to nearest Lot Line
Septic/Holding Tank IAbsorption Area
ISewer Line
INearest Lot Line
5.' COMMENTS
DATE
~VED FOR ~' BEDROOMS
[] CONDITIONAL APPROVAL {lette[.must acco~npany certificate)
[] DISAPPROVED
72-010 (Rev. 6/79)
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I. D. 051-582-23
1. GENERAL INFORMATION
Expiration Date: q1 )3 - 2© ZS
Complete legal description THUNDERBIRD HEIGHTS #1 BLOCK 4, LOT 32
Location (site address) 27908 RAVEN COURT, CHUGIAK, AK 99567
Current property owner(s) ALBERT & JOYCE BELLINGER Day phone
Mailing address
Real estate agent
27908 RAVEN COURT, CHUGIAK, AK 99567
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
3
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
❑
Private Septic
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
®
Public Sewer
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $
Date of Payment q 113
a Do2,7
Receipt Number 8-03 1 VY
Waiver Fee $
Date of Payment
Receipt Number
COSA # QSG22 l (-j Ol Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Address 13030 SUES WAY, ANCHORAGE AK 99516
Engineer's Printed Name CURTIS HUFFMAN, PE Date 4/12/2022
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the l`
well and septic system. Therefore, any estimate of how long a system will function satisfactory ��Q:• • - • . ;1 �]
for current or future occupants or guarantee that no unseen encroachments, deficiencies or j g-- •9 f�
discrepancies exist can be given by First Water Consulting & F / *� TM •.*
WfS .. .......
6. DSD SIGNATURE ' • . • .. • • • • �"
• • Curtis Huffman
System #1 Approved for 3_— bedrooms �f��F��u;•, CE 128991�
System #2 Approved for bedrooms �l>PROF S oNa�``� `
Disapproved
Conditional approval for bedrooms, with the following stipulations: j
C'�C7-i-i G A jo a w -} `- i l I S 3 S o 1
C�m dV Q t,uti."
OF
J� ON-SITE
WATER AND
MPROGKAM o
By: ( Orifi,F Z Z
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
Legal Description: THUNDERBIRD HEIGHTS #1 BLOCK 4 LOT 32 Parcel ID: XXXXXX
If more than 1 septic system on lot: COSA Checklist # _of _ Structure served by this system
A. WELL DATA — PUBLIC WATER — CLASS A PWSID #21156
❑ Well log is filed with Onsite (or attached) Well production at time of test _gpm
Date drilled Water storage tank volume_ gallons
Total depth _ft Well disinfected for coliform test? ❑ Yes ❑ No
Cased to _ft ❑ Coliform bacteria is Negative
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) _in.
Date of flow test for COSA
Static water level at beginning of test _ft.
Comments
B. TANK DATA
Age of tanks) 10 years
Tank type/material SEPTIC /STEEL
Measured operating fluid level in septic tank 50"
® Standpipes/foundation cleanout per record drawing
Date of pumping 4/13/2022
D. ABSORPTION FIELD DATA
Which system tested (date installed) 7/15/1981
® ALL standpipes present per record drawing
Total measured depth from grade 3_3 ft (max) (GRADE)
Measured depth to pipe invert from grade 3.3 ft (min)
❑ N/A – pressurized field
Nitrate _mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ❑ Arsenic less than MRL (ND)
Collected by_
Date of Sample
C. LIFT STATION
❑ Required maintenance completed
Age of lift station _ years
Lift station material.
Comments:
Adequacy test date 4/13/22
Results 0 Pass For 4 bedrooms
Fluid depth prior to test 4 in
Water added 600 gal
New depth 7 in
❑ Monitor tubes go to bottom of effective. If not, state Elapsed time <30 min
depth into effective 1' PER SHOTS PERMIT SHOWS 6'ED
® fluid depth 4 in Code -required soil cover over field * Final—
❑ System presoaked Absorption rate 600 gpd
(Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N
date of test) If yes, enter date
Gallons introduced gallons
Comments/Deficiencies: *DCO/SUMP SHOTS & AT GRADE. 2012 COSA SHOWED 52" IN SUMP WITH 3 3' OF COVER W/
NO KNOWN FROST ISSUES. RECENT TESTING & ELEVATIONS SHOW 1' ED IN RUSTED CAST IRON SUMP
FW'i;
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
® Yes
if No
Community Sewer Manhole/Cleanout > 100'
If absorption field is under driveway comment below
❑ Yes
if No
ft
❑ Yes
if No
Neighboring Tank > 100'
❑ Yes
if No
ft
Private Sewer/Septic Line > 25' ❑ Yes
if No
Absorption Field on Lot > 100'
❑ Yes
if No
ft
Holding Tank > 100' ❑ Yes
if No
Neighboring Absorption Fields
> 100'
F. ENGINEER'S COMMENTS
Animal Containment > 50' ❑ Yes
if No
❑ Yes
if No
ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75'
_
❑Yes
if No
ft
El Yes
if No
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
® Yes
if No
ft
Surface Water > 100' ® Yes
if No
Property Line > 5'
® Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
® Yes
if No
ft
Private Wells >' 100
_ ®Yes
if No
.Water Main >..10'
® Yes
if No
ft
Community Wells > 200' ® Yes
if No
Water Service Line > 10'
® Yes
if No
ft
If septic tank is under driveway comment
below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
® Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
® Yes
if No
_ ft
Wells on Adjacent Lots:
Water Main > 10'
® Yes
if No
ft
Private Wells >' 100
_ ®Yes if No ft
Water Service Line > 10'
® Yes
if No
ft
Community Wells > 200' ® Yes if No
Surface Water > 100'
® Yes
if No
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that 1 have determined through field inspections and review �y `•¢��[
of Municipal records that the above systems are in conformance �`.•,� ���
with MOA COSA guidelines in effect on this date.
.. ........
0 .... ....�..�.`...
. Curtis Huffman
CE 128991
�l®F�pROFESSI* -*
ft
ft
ft
ft
ft
ft
ft
ft _