Loading...
HomeMy WebLinkAboutFIRE LAKE BLK 3 LT 11AFire Lake Block 3 Lot I I A #051-361-26 i.Wi Municipality of Anchorage ,;�; -?•, Development Services Department Building Safety Division On -Site Water and Wastewater Program, 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW020420 PIDNumber: 051-361-26 Name' —Ryan McCormick Wastewater System: ® New ❑ Upgrade Address: 12263 Lake St.. Eagle Riygr. AK 99577 ABSORPTION FIELD Phone: Number of Bedrooms; 694-4690 4 ® Deep Trench O Shallow Trench O Bed 0 Mound 0 Other. LEGAL DESCRIPTION Soil Rating. Total Depth from original grade: Block' La. Subdivision: 3 11A O.8 GPD/Fe Depth to pipe bottom from onginal grade, 12 Ft. Gravel depth beneath pipe; Fire Lake 3.93 Ft. 8.07 Ft. Township: Range; Section: Fill added above original grade, Gravel Length: < 0 Ft. 47 Ft. Well: ®New Upgrade Gravel width: Number Ohms: Distance between lines; 3.0 Ft. 1 NA Ft. Classification (Private. A. B. C): Total Depth: Cased b: Total absorption area: Pipe Material. Private 81 Ff. R1 Ft 750 Fe D3034 & F810 Driller. Date Dribod: Stanc Water Level: Installer: Date Installed: Sullivan10/25/02 43 F, McCormick -owner 5/9/2003 Yield: Pump Set at:Casing 2 Height Above Ground: TANK CPM unknown Ft. 2 Ft SEPARATION DISTANCES ® Septic p Holding 0 S.T.E.P. 0 Other: 7o Septic Absorption Lift Holding Public/Private —ami acto.a" apacdy. From Tank Field Station Tank Sewer Line Anchorage Tank 1250 Get. Wen 100'+ 100'+ NA NA 25'+ Material: Number of Companmems: Steel 2 Surfacewater 100'+ 100'+ NA NA LIFT STATION Lot uric 5'+ 10'+ NA NA 18 aria accurer. Gal Foundation 5'+ 10'+ NA NA P'anP on, Iovel at. 'Pump elf level aL High water alarm at: in . In. in. curtain Drain NA *50'+ NA NA Pump Make d Model Electrical inspections performed by: Remarks: *none known BENCH MARK tank & field insulated Location and Description: Bottom of siding Assumed Elevation: 100 Ft. Engineer's Stamp OF•It'C��� v ��(a r'lt • a� 9,II Inspections performed by: KND Engineering, Inc_Dates: 1stz5/9/2003 Z. % /a••:a4�. w,...a..a •, 0 DeveloPmen Services 26 "d 5/10/0 Department Approval �°II(e-rja3 / a . .............. ... I� �aKenn CE Reviewed and approved by:•' Date: 12r 71t4 t19F0 fRev.a-Dol ...**.. i ROt;,t�A i.Wi AS -BUILT SYSTEM DETAILS/SITE PLAN Permit SWO20420 FIRE LAKE S/D BLOCK 3, LOT 11A PID#051-361-26 lI I 1— I\ I F—I I-1 ----------- SCALES I -=,50'— - - I A—C= 21.1' B—I C= 33.5' W A—D= 20.8' B—D= 33.0' A—E= 59.4' B—E= 87.2' A—F= N B—F= qa 97.28 FINAL GRADE 47.0' PREPARED FOR: SCALE, NTS 7e 9 K" Ryan McCormick 12263 LAKE ST. EAGLE RIVER, AK. 99577 (907) 694-4690 FIELDBOOKS COMPUTED: D �ARw v DRAM'. LEND ENGINEERING WAXING: CHECKED: KLID 20441 PTARMIGAN BLVD. ASBURT: DATE: 1 1115/03 EAGLE RIVER, AK 99577-8736 oro. FILE: CRO NW453.:................................................ A`AD FILE` 03043.DWG 0B " 03043 (907)696-6111/FAX (907)696-8111 7(n rp� 6 qa 97.28 FINAL GRADE S 97.49 nTt� rA�Rtt vAAI 5GAL 93.9 EWER ROCK �i� �1 i 47.0' PREPARED FOR: SCALE, NTS 7e 9 K" Ryan McCormick 12263 LAKE ST. EAGLE RIVER, AK. 99577 (907) 694-4690 FIELDBOOKS COMPUTED: D �ARw v DRAM'. LEND ENGINEERING WAXING: CHECKED: KLID 20441 PTARMIGAN BLVD. ASBURT: DATE: 1 1115/03 EAGLE RIVER, AK 99577-8736 oro. FILE: CRO NW453.:................................................ A`AD FILE` 03043.DWG 0B " 03043 (907)696-6111/FAX (907)696-8111 j�dv e.rtt teb )0rattug, log by DOC CO.Cba SULLIVAN WATER WELLS P.O. BOX 670272, CHUGIAK, ALASKA 99567 • TELEPHONE 688-2750 OWNER OF LAND: 1Q Y'�L COI . 4h"e BOREHOLE DEPTF ADDRESS: c,,,,,, LEGAL DESCRIPTION: 6-0,1Z 449 fE' I?L4 DATE: PERMIT NUMBER:/2o%04rZO__Daa�t.-e'/IoflssueL0-A-51 .. TAX IDENTIFICATION NUMBER: aY—L-A3 6 1 - 576 a Is well located at approved permit location? 6At'5 U No e Method of Drilling: 41el otary U cable tool Depth of well: 4?1- Casing Type$ ?,5 -Wall Thickness 'a inches Diameter inches, depth �� feet L .r Type: Casing Stickup Above Ground: oZ feet Static water Level 4 3 feet Recover Rate: qpm Method of Testing:ilf� Well Intake Opening Type: en end O open hole u Screened; Start feet Stopped feet L1 Perforations Start fe t opped feet Grout Type: 15- 7304' Volume / a0 titi' Depth: from L7 feet, to V feet Well Disinfected Upon Completion? &-Ye's D No Method of Disinfection: C NG D R„J c S� ►�i�� 1 Comments: o U F,� J rZ dJ ,a's^► Hof����� � 5//xwj 4 f- G R N %J (L)`/Pt /e��/�r+. S Sofw o 6 #C K o t5 e. >(t7 /aizr�,1c� i A.r Driller's Name�-�- ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. £00lz S7.'%'P.L7r1SKo0 10211 CM ZZS LO6 Xdd OS:CT C0/90/0T Comments: o U F,� J rZ dJ ,a's^► Hof����� � 5//xwj 4 f- G R N %J (L)`/Pt /e��/�r+. S Sofw o 6 #C K o t5 e. >(t7 /aizr�,1c� i A.r Driller's Name�-�- ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. £00lz S7.'%'P.L7r1SKo0 10211 CM ZZS LO6 Xdd OS:CT C0/90/0T MUNICIPALITY OF ANCHORAGE Development Services Department 1� On -Site Water& Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW020420 Legal Description: FIRE LAKE BLK 3 LT 11A Design Engineer: 0024 Eagle River Engineering Services Owner Name: Ryan McCormick Owner Address: 12263 Lake St. Eagle River , AK 99577 - Date Issued: Oct 16, 2002 Expiration Date: Oct 16, 2003 Parcel ID: 051-361-26 Site Address: 018107 MENDENHALL ST Lot Size: 31450 SO. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: F✓ Disposal Field Q✓ Septic Tank Holding Tank E] Privy All construction must be in accordance with: 1. The attached approved design. Z✓ Private Well F� Water Storage 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: le l6%p -Z a&z a Zg& � — Date: jobL d —� Municipality of Anchorage (• Development Services Department �•' Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. I °T• P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWERNVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. _051 — 3(p / — a (o Permit Number SWO2049-0 Property owre /1 phone a a - 73Za— Mailing address (1) ;tPb3 [' Q,�e_ X6/1.. Mailing address (2)E aGyle 1 l t.�/1 Zip Code Legal description (Lot, Block & Sub'd.) %C� ►/�% A , A Legal description (Section, Township & Range) f ! ✓°� LQ.kQ. Lot Size 3 1 `y S" Ac;es/Sq.Ft. Number of Bedrooms 41 THIS APPLICATION IS FOR: Sewer Only ❑ Well Only ❑ Sever and Well Water Storage ❑ Seaver Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. property owner or authorized agent) Permit Fees: Waiver Fees: Date cf Payment: /b A A Data of Payment: Receipt Number: �a&eogj4 Receipt Number. (?,ay. �2:w) Eagle River Engineering Services Louis Butera, P.E. P.O. Box 773294 Eagle River, AK 99577-3294 October 3, 2002 Jim Cross, P.E. Manager, On -Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Re: Fire Lake, Alaska Subdv. Lot 1 IA, Blk 3 Narrative & Permit Application Dear Mr. Cross: (907) 694-5195 tel (907) 694-3297 fax The proposed septic upgrade/well and septic system will have very limited impact on adjacent properties for the following reasons: The surrounding lots are large, allowing sufficient room for septic sites. 2. Immediate neighboring septic systems are all +30' distance. 3. Reserve space is adequate, due to absorption capacity of the soil and no water table, allowing trench type leachfields. 4. Drainage will not be affected and is not a major consideration in our design. This installation of a well and septic system will not affect the development of adjacent lots. If you have any questions please call our office at 694-5195. Sincerely, Louis Butera, P.E. \2002\02-006 SErncNARRATIVEMOC Eagle River Engineering Louis Butera, P.E. P.O. Box 773294 Eagle River. Ah 99577-3291 Services (907) 694-5195 tel (907) 694-3297 fax SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM LEGAL: Fire Lake, Alaska Subdv Lot I IA Blk 3 October 3, 2002 A. GENERAL 1. The well and septic plan are for a single family residence only. 2. The drawing and or site plan shall be a part of this specification. 3. All materials and workmanship shall meet the Anchorage Department of Health and State Department of Environmental Conservation requirements. 4. All soil tests are advisory to the design and are to be verified or modified in the field by the engineer. 5. All excavations and depths are advisory and are to be verified in the field by the contractor to meet Municipality of Anchorage, Department of Environmental Conservation requirements. 6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any adjacent multi- family wells. 7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer approval. 8. It is always recommended that a surveyor locate the nearest lot line position and the location of any easements. 9. Any remaining open test hole excavations shall be filled and monitor pipes removed. B. SEPTIC TANK and SEWER PIPING 1. The sewer piping from the house shall be 4" PVC 3034 laid at 2% grade maximum - 11% minimum and insulated where it is under driving surface with 4" of burial foam, 2' wide centered over piping. 2. Septic tank shall be minimum of 1,250 gallon tank of MOA approved construction, insulated or place with 4' of soil cover. C. TRENCH I. The trench is to follow the natural land contour to maintain uniform total depth of the trench bottom. 2. The bottom of the open trench excavation shall be level, plus or minus 1.5" prior to placing gravel. 3. The total depth of the trench excavation is not to exceed 12' at any point in relation to natural ground surface. 4. The 8' of effective depth sewer gravel and effluent pipe is to be covered with typar fabric material. 5. Soil or combination of soil and extruded board insulation to a depth of 3' or equivalent is to be placed over the leachfield. 6. The area over the trench is to be finish graded to prevent ponding of surface water runoff. 7. The septic tank and leachfield must not be closer than 100' to any existing private well, 150' to any Class "C" well, or 200 feet to any community well. RECOMMENDED LEACHFIELD DIMENSIONS: TOTAL DEPTH= 12' GRAVEL DEPTH = 8' under pipe, 2" over pipe TRENCH LENGTH= 47' TRENCH WIDTH = Y or bucket width. SOIL RATING= 0.8 GPDI BEDROOM CAPACITY= 4 SEPTIC TANK = 1250 minimum 2 inspections required - Twenty-four (24) hours notice required for all inspections. 12002'.02-006Trcnch- spccduc ADJACENT WELL +100' SEPTIC +100' FROM PROPOSED WELL S80 -'59'30"E 170.00' 20' UTILITY EASEMENT CD o O O 0 / Ln 00 L07/1 1-A 0 o � CLASS C O WELL+150' 45' _ , O o PROPOSED Z VACANT LOT HOUSE 45' 24' '� 15• ? RESERVE g 25 ' O AREA 16' PROPOSED 40' H 3 WIDE WELL O 47' LONG TRENCH' " ••DRIVEWAY' Z C • \ \�--k • ~ o S89059'30"E 170.00' o n MENDENHALL STREET VACANT LAND NO SURFACE WATER NO KNOWN CURTAIN DRAINS - TEST HOLE • - MONITOR TUBE c - SEWER CLEAN OUT Q - WELL — — - EASEMENT PROPOSED LEACH FIELD ©- DRIVEWAY WELL/SEPTIC SITE PLAN EGAL:LOT 1 1—A, BLOCK 3 FIRE LAKE ALASKA SUB iWNER: MCCORMICK :ONTRACTOR: N/A 08# 02-06WS I DATE: 10/037021 SCALE 1 " = 40' EAGLE RIVER ENGINEERING SERVICES P.O. Boz 773294 EAGLE RIVER, AK. 99577 (907) 694-5195 FAX.(907) 694-3297 .OF������ 1IIIIII 1 �* :449TH /'V••• *�� .... ,• c • LOUIS A. BUTERA � ////%.7�� •' • • CE -6736 • ••_ III I I I"8� ESS100IOL EAGLE RIVER ENGINEERING SERVICES P.O. Box 773294 Eagle River, Alaska 99577 (907) 694-5195 ERES Project No.: 02-006 Calculated By: LB Date: 10/3/2002 Legal: Fire Lake, Alaska Subdv Lot 11A Blk 3 Single Family 4 Bedroom Dwelling Deep Trench Subsurface Wastewater Disposal Field Water use at 150 gallons per bedroom = Percolation rate = Wastewater application rate = Required absorption area = Trench width (Vv) = Gravel depth (D) _ TEST HOLE 1 600 gallons 10 minutes per inch 0.8 gallons per day per square foot 750 square feet 3 feet 8 feet Required length = Required absorption area / 2 / D Required length = 750 / 2 / 8 Required length = 47 feet Total Excavation Depth = 12.0 feet a . ..-...... LOUIS A. EUTERA. r•. CE -66736 ��4�F�Ck Ec5:0� oQ 02-OO6MOA_onsite_Cal.xis 5:57 PM 10/3/2002 .. Of 41. %t �A ALT a�Nf:INFIt�'C r�9� • r, Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street. Anchorage. Alaska 99502-0650 Louis A. Butera e! SOILS LOG — PERCOLATION TEST �Uesti, CE -6736 PERFORMED FOR: RYQn M<cYml k DATE PERFORMED: ILIO Z 1l.. R14!4'4 LEGAL DESCRIPTION:c_1 I re 1 p K& et II -R, 8161 Township. Range. Section: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18- 19. 20 Top, ail Govel4 0179QrtfG htlz SLOPE TN GM Sandy Grave( WA S;lt. f / Crclyr Ve+n3C1QrV WASGROUNOWATER / ENCOUNTERED? S IF YES. AT WHAT L DEPTH? 0 P E Ototh to Water Atter Monitoring? Pttx Cate: 41/.2T/oz 11 I le Reading Date Gross Time Net Time Depth to Water Net Drop 0 I It -26-02 5:'F2.30 3 2 u ')O 16 mtn 4 r i6v t` 0 Ir f v u :2 Is 1 iN 4 eyi6 rr 1 'Kir I uPERCOLATION RATE tmmu:es mcm PERC MOLE DIAMETER _t�_ r TEST RUN BETWEEN' FT AND F / FT COMMENTS yds 7��.+r�r SyrTc-n �P-ee Oi..�i .F- /oro /noriror' is 3 O Cyr wi%/ tom! f1/./.✓ /��i.. rie .c f.. I� r PERFORMED BY: E. R , E.S. I - r�-'� CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT CN THIS CATE CATS Page 1 of 1 Subj: RE: duplex separation distance !Date: 10/8/2002 5:36:27 PM Alaskan Daylight Time From: Keven Kleweno@envircon.state.ak.us To: LBeres@aol.com, Keven Kieweno@envi,rpo.n-.,state.ak..us Sent from the Internet (Details) Lou; If you have a source well that is only serving a single duplex, the source well is classified as a private source well. With this classification, the separation distance between the source well and the new wastewater disposal system is 100 feet. If the duplex is served by one septic tank and SAS, the installation will need to be documented by completing the department's "Documentation of Construction" form and submitting the completed form to the correct ADEC office. If the existing duplex is served by two septic tanks and SAS [one for each side] and it is within the MOA, the wastewater information is worked through the On -Site Program with the Municipality. Else where in the state, the department's "Documentation of Construction" form is used. hope that this is the information you needed. Keven —Original Message— From: LBeres@aol.com [mailto:LBeres@aol.com] Sent: Tuesday, October 08, 2002 8:29 AM To: KKleweno@envircon.state.ak.us Subject: duplex separation distance Kevin realize that duplexes are now defined as "private water systems" requiring only 1 00'separation from well to septic systems. Is it allowed to place a new septic system at 1 00'from an existing well that was registered as a class C well and is serving a duplex dwelling? Lou Butera, PE Eagle River Engineering Services Eagle River Alaska Tel. 1-907-748-5195 Fax 1-907-694-3297 Wednesday, October 16, 2002 America Online: LB eres May 9, 2003 On Site Services Department Municipality of Anchorage P.O. Box 196650 Anchorage, Ak 99519 Re: Fire Lake, Alaska Subdv. Lot 11A, Blk 3 Notification, Septic Installation by homeowner Dear On Site personal: This letter is to notify the on site water and wastewater staff that the property owner (Ryan J. McCormick) and his brother (John M. McCormick) will be installing an on site wastewater disposal system. The date of installation will be between 5-9-03 and 5-11-03 weather permitting. We are using equipment rented from DJ's Alaska Rentals (Cat 416c tractor back hoe and Case 4520c dozer) also John McCormick will supply his dump truck and skid steer loader. John McCormick and I both have vast background of the construction field, with John being the senior field operator. He has many years of experience operating heavy equipment. If you have any question regarding this matter you may contact Ryan McCormick at home 6944690 or cell 223-7882.or you may contact my engineer Lou Butera at 694- 5195. Thank you for time in the matter. Sincerely, Ryan J, McCormick