Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BRITT LT 227A
. .. _ I., .. .... Britt Lot 227A #018-332-27 Municipality of Anchorage Development Services Department Building Safety Division?, On -Site Water & Wastewater Program, 4700 South Bragaw St. ° P.O. Box 196650 Anchorage, AK 99519-6650 ' r 1 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number. SW020390 PID Number. 018-332-27 Name: DEBRA BRITT Wastewater System: O New ■ Upgrade Address: 3540 DORA AVENUE * ANCHORAGE, AK 99516 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 258-2000 4 D Deep Trench ■ Shallow Trench D Bed DMound 0Other LEGAL DESCRIPTION Son ": sell Total Depth from original grade: GPD/Sq. R 1 MAX rt Block: Lot: Subdivision: — 227A BRITT Depth to pipe bottom from original prod.: Grovel depth beneath pipe: SEE DWG. FL 0.6 R Township: — Range: — Section: rm oddw above W41ml grad« Growl MrIm _ SEE DWG. R (2 ® 15') 30 TOTAL R WELL: O New p Upgrade G1e" wath: 5.0 Number of Brett: Dlstance between Sew: 2 15+ Gleeelfication Private, A9,G . Totd DeGoeed To: Total abeorptbn ares: R R Pipe material:R R 150 so. Pt. D 3034/ SCH 40 PVC Driller. Dole Drilled: Stat{o Water Level: installer. Dab kwblled: R AKWWC 11/12-18/2002 Yield:mp Puset At: Ab casing Height Move Ground: GPif R R TANK SEPARATION DISTANCES aSeptic °Holding 0S.T.E.P. ■Other* T° Septic Absorption Lift Holding PublIc/Prlwb Mona' Capa� In gal From To Fwd Station Tank SO~ un« ANCHORAGE TANK 1500 Well 100'+ 100'+ 100'+ — 25'+ FIBERGLASS Humber of camporimenb. 2 Surface Water 100'+ 100'+ 100'+ — — LIFT STATION / PUMP VAULT Lot Line 5'+ **5' 5'+ — _ e In gallons: Manufwb~. 1500/500 ANCHORAGE TANK ORENCO SYSTEMS Foundation 5 + 10. + 5, + — — Pump an level at: -pump off level at I High water olarm at TIMER 32" TIMER 22" 46736" Curtain Drain NONE KNOWN Pump Mab t Model: Oeatncd InsPeNbne Perfom»d W. I ORENCO M.O.A. Remarks: BENCH MARK *THIS IS AN ADVATEX TREATMENT SYSTEM Location and Description: TOP OF GARAGE SLAB —EXISTING SEPTIC SYSTEM COMPLETELY ABANDONED PER THE UPC Assumed Elevation: 109.00 R "VERBAL 5' LOT LINE WAIVER GRANTED BY DAN ROTH ON 11/8/2002 ENGINEER'S S LQooQpp • o F �p ,`Q., • . 540 Inspections performed by: AKWWC, INC. Dates: 1st CIO) T ' 0 _11/12/2002 O. ............� 2nd 11/13/2002 4 3rd 11/18/2002 QO ..� f ey Gam ss;' ' c 79 Development erv' s Department Approvalapp by: v •. viewted and approved 4fZ Date: ptR�e pi°fessloll ��00000�a Ia PERMrr SW0 NUMBER: AS—BUILT DRAWING PARCEL ID NUMBER: SW020390 018-332-27 f y EXIsnNc FOUNDATION oR �' CLEANOUT GSF'�i+ I A 1 � \ EXISTING WELL NEW 1500 GALLON \� ADVANTEX TREATMENT SYSTEM BL1 \ � S �DBL2 TH/2 / THERE WOULD BE SOIL BALLAST OVER NEW DRAINFIELDS F_ T a -1 DBL1 59.42 106.97 DBL2 60.01 110.96 STI __Mil 80.89 110.96 1 85.66 109.17 MH2 81.93 102.91 MT1 123.65 80.77 MT2 135.25 88.59 MT3 116.61 86.26 MT4 130.09 95.99 ' 12/2/200 __.,.,.._._.._.�,_.�.`_,._�.._... _.. .____._....... -.. __..__ DRAWN BY: 4 C.J.G. ALASKA NATER &, ti�ASTL`VATER LE CONSULTANTS, INC. SCALE* = 40� 6901 DERARR ROAD, SUITE 28 • ANCHORAGE. AK 99504 • PHONE (907)337.6179 • FAX (907)33A-32(.6 PREPARED FOR: PHONE NUMBER: PAGE NUMBER: DEBRA BRITT (907) 258-2000 2 OF 3 LEGAL DESCRIPnON: BRITT SUBDIVISION; LOT 227A, TYPE OF WORK: AS -BUILT DRAWING OF SEPTIC SYSTEM UPGRADE ,1 I I 1 jane S; ♦i CAo PERMIT NUMBER: SW020390 AS -BUILT DRAWING PARCEL NUMBER: 018-332-27 TOP OF ADVANTEX POD TOP OF MANHOLE - - 87.17 (AVC.) 87.26 (AVC.) FINAL GRADE - TOP OF MANHOLE - 87.0+ 87.59 (AVG.) FLOAT INSULATION TOP OF TANK�� II - 83.16 TOP OF TANK �- - 83.16 INVERT OF PIPE - 82.29 — FILTER TOP OF SAND - 90.27 (AVC.) - BOTTOM OF TRENCH - 9937 (AVG.) 1141 GRADE - 92.96-9332 F 0RICIW1l GRADE I - 90.99-9137 FILTER TOP OF - 92.45 INVERT OF PIPE - 90.67 (AVC.) THE DISTRIBUTION UNE WAS 1 M INCH PVC WITH 0.25 INCH HOLES SPACED EVERY 10 INCHES (15 HOLES) F --i o•+--{ TO DRAIN FIELD ORENCO PUMP VAULT FINAL GRADE - 95.63-96.36 oRK5NA1 - 932: WERT OF PIPE - 93.08 (AVC.) THE -BOTTOM OF DISTRIBUIWN UNE TRENCH . WAS 1.25 INCH PVC 91.48 (AVC.) WITH 035 INCH HODS SPACED EVERY 10 INCHES (15 HOLES) RELATIVE ELEVATION OF GROUNDWATER - 87.59 RELATIVE ELEVATION OF BOTTOM OF TESTHOLE - 85.34 $ 4 RELATIVE ELEVATION OF GROUNDWATER - 85.52 RELATIVE ELEVATION OF BOTTOM OF TESTHOLE - 83.27 DATE: ', Jl� 12/2/2002 e JL/ % Ir1M' i DRAWN BY. ap� ALASKA WATER & WASTENVATER SCALE, oma, y� --• CONSULTANTS, INC._: 6901 DEBARR ROAD. SUITE 28 • ANCHORAGE. AK 99501 • PHONE (907)337.6179 • FAX (9071338-321.6 N.T.S. PREPARED FOR: PHONE NUMBER: PACE NUMBER DEBRA BRITT (907) 258-2000 3 OF 3 f mes LEGAL DESCRIPTION: �A 795 e1. BRITT SUBDIVISION: LOT 227A, Qn of .�o TYPE OF WORK: PROFILE AS -BUILT DRAWING OF SEPTIC SYSTEM UPGRADE �DOprO 5510t\ O� o00 1/- Q-02 I:o© MUNICIPALITY OF ANCHORAGE Development Services Department 3 0 On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW020390 Legal Description: BRITT LT 227A Design Engineer: 0041 AK Water & Wastewater Consultarr Owner Name: DEBRA BRITT Owner Address: 3540 DORA AVENUE ANCHORAGE. AK 99516 - Date Issued: Oct 07, 2002 Expiration Date: Oct 07, 2003 Parcel ID: 018-332-27 Site Address: 003540 DORA AVE Lot Size: 49450 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of. F✓ Disposal Field Q✓ Septic Tank F� Holding Tank Privy Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. . EXISTING ABSORPTION FIELD WILL BE PERMANENTLY DECOMMISSIONED OR GROUND WATER MONITORING THROUGH A HIGH GROUND WATER PERIOD (MAY 15 OR OCTOBER 15). 1119102 FSG. to Ag -TO #eis4 1iv e Rpj.Ava w +4 ren ° 081-H 4. o r L/ NF, PvWl &f? &.r- , [ c 'Ct 7WC:- F -14-s7-- Received By: Issued By: 19 2&- �� o Date:— 1010710-2. �' �1. yaq- Date:10/7/0?— ALASKA WATER F& WASTEWATER CONSULTANTS, INC. November 7, 2002 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 RE -DESIGN Permit# SW020390 JLrb�` f� fPry %,,,F�� 5 4C-1 Ro+k oV\ I1/g%2 1p --N j-0+ ',,C- V4A►vJ Ref. Proposed Septic System Upgrade for Lot 227A; Britt Subdivision ADVANTEXTI' TREATMENT SYSTEM To whom it may concern: 1. GENERAL: A permit was issued on this property on 10/7/2002. Prior to construction of the septic system the excavator noted that groundwater was at 3.5 feet below the ground surface making the site unuseable this test hole is in a Swale and was probably being ifluenced by surface runoff. A new testhole was dug east of the original teshole. We are proposing to design the septic system around the 30 foot radius of this test hole. Due to high groundwater and limited amount of receiving soils, we are proposing to use an Advantex treatment system and a 5 -wide trench type drainfield. 2. SOILS: See the attached log, which shows the soil classifications, groundwater monitoring, and the percolation test results. 3. DRAINFIELD APPLICATION RATE: The intent is to install an Advantex treatment system that will allow the use of a small drainfield in the area around the 30 foot radius of the test hole. The Advantex system has received class III approval and we are going to conservatively assume an application rate of 4.0 GPD/FTZ. 4. TRENCH DESIGN: a. Percolation Rate: 3.3 minutes/inch b. Proposed Application Rate: 4.0 GPD/fl' (6.0 GPD/ FT allowable application rate) c. Number of Bedrooms: 4 d. Design Flow: 600 gallons per day e. Minimum Absorption Area: 150 f12 f. Total Depth: 2.0 feet (max. at any point) g. M.O.A. Approved Sand Filter Depth: 1 foot h. Effective Depth: 0.5 feet 6901 Debarr Road, Suite 2-13 * Anchorage, Alaska 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com i. Width: 5 feet j. Minimum Length: 30 feet long k. Effective absorption area: 150 ft2 5.ORENCO PACKAGE SYSTEM: The STEP tank with the Advantex Treatment System will be manufactured by Anchorage Tank & Welding to meet the latest design criteria established by Orenco Systems, Inc. The point of contact at Anchorage Tank is Lowell McNutt. As with their standard STEP tank, it is equipped with a high water alarm per M.O.A requirements. 6. SURFACE WATER: There is no surface water within 100 feet of the proposed septic system upgrade. 7. TOPOGRAPIIY: The average slope in the area of the proposed drainfield area is <20% slope, in short there are no slope concerns. 8. CLOSING: I am open to any suggestions from your department that would be an improvement to the proposed system. I am unaware of any negative impacts that this installation would impose on adjacent wells, or septic systems. If you have any questions, please call us at 337-6179. i /I M.S. NOTE. Attached is a site plan draining, a design drawing, an Advantex detail, a trench detail, a soil log, and a 7 page construction specification letter which are all part of the design package for this septic system. 6901 Debarr Road, Suite 2-13 * Anchorage, Alaska 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com � / / 1 I i T12N, R3W SECTION 33; I LOT 214 I I I I I I--------------------- DORA AVENUE ------------------------------------------ r I KENAI VIEW S/D; I I I i � \ EXISTING 4 BEDROOM HOUSE LOT 3 I EXISTING SEPTIC % i ",:iy-y3• \ SYSTEM .:,�"y�•,-'.f4i•.i51•,*'.� / / —_t I BRIT S/D; / I T12N. R3W. SECTION 33; ______ LOT 2278 / LOT 226 1 / \ 1 / \\ I TH 2 THS_— CSS \� KENAI VIEW S/D; I C \ I LOT 6 \ CSEPTIC��� --- AREA.---=� ------------ -f---------- - \ -------s—J----1 / \ \ I / nn• WFII RAnIIIR 1 PROPOSED SEPTIC UPGRADE [ — 1 (SEE DESIGN PAGE 2 OF 4) 1 I I I I I T12N, R3W. SECTION 33; / T12N, R3W. SECTION 33; LOT 245 LOT 246 I I I I I I I I I 1 I I ` ,. DATE: 11/7/2002 <� ii`.za ��. .•. .. ,q `+I)O� DRAWN BY:+' ALASKA NATER & AVASTEAVATER c.J.c. --• ��^^--�^�-- CONSULTANTS, INC.—•• '% 4 T S 6901 DEBARR ROAD. SUITE 28 • ANCHORAGE. AK 90504 • PHONE (907)337.6179 • FAX (907)338.324.6 _ 1 00 I.......... ... ............s^ 1 A PREPARED FORA PHONE NUMBER: PAGE NUMBER: DEBRA BRITT 258-2000 1 OF 4 " i= e r y Gar ess �I, . 'I�, E 953 LEGAL DESCRIPTION: BRITT SUBDIVISION; LOT 227A +11�°� ' •. > TYPE OF WORK: SITE PLAN FOR SEPTIC SYSTEM UPGRADE �`�' ° >` RE-DESIGN ------ --------------- NOTE: THE CONTRACTOR SHALL HAVE ALL WELL RADII SHOWN, / FLAGGED BY A REGISTERED LAND / SURVEYOR PRIOR TO CONSTRUCTION '... '. 'a \ ••..'... I UNDATIONUT ypG`S C �y I EXISTING SEPTIC TANK../ TO BE COMPLETLY ABANDED PER UPC ` EXISTING WELL / EXISTING DRAINFIELD IS \ CO * / ENCROACHING UPON GROUNDWATER AND $ MUST BE COMPLETELY ABANDONED PROPOSED DRAINFIELD. EXCAVATE A \ TRENCH THAT IS 2 FEET DEEP MAXIMUM BY 5 FEET WIDE BY 30 FEET LONG. ADD 1 FOOT OF M.O.A. TH12 / APPROVED SAND FILTER THEN ADD 0.5 FEET i O TH/1 �i OF CLEAN, WASHED SEWER DRAINROCK. THE �i DISTRIBUTION UNE IS TO BE 1.25 i INCH PVC WITH 0.25 INCH HOLES PROPOSED 1500 GALLON M SPACED EVERY 10 INCHES ON CENTER 30 HOLES TOTAL (SEE ADVANTEX TREATMENT SYSTEM r/ UFT PUMP DETAIL PACE 4 OF 4) (SEE DETAIL PACE 3 OF 4) _ _ _ 5' LOT UNE WAIVER / REQUESTED .. , DATE: 11/7/2002 0 0t t a. DRAWN BY: WATER & WASTEWATER C.J.G.ALASKA SCALE: CONSULTANTS, INC. DEBARK ROAD, SUITE 2R • dNCNOR4GE. OK 9950E •PHONE (907)137.6170 • Fe% (907)33R-S2L6 "40' ............6001 ...... VADEBRA PREPARED FOR: PHONE NUMBER: PAGE NUMBER: BRITT 258-2000 2 OF 4Oof eys. pLEGAL 3'CaQ DESCRIPTION: BRITT SUBDIVISION; LOT 227A u40edQo� TYPE OF WORK: DESIGN OF SEPTIC SYSTEM UPGRADE 0400 rofesslslooc�o\es NOTE. JIM CROSS. P.E. HAS THE ADVANTEK MANUAL aiiii WE NOTE: THE BOARD INSULATION TO BE INSTALLED OVER THE SEPTIC TANK & 4' BEYOND ON ALL SIDES EXCEPT UNDER THE ADVANTEX FILTER. THIS WILL ALLOW FOR HEAT TO ESCAPE FROM TANK & RISE TO THE FILTER ABOVE IT. G' JIM CAP— FINAL CRADE� ft 7, 6' PVC PUMP -OUT (TYP.2) 6' PVC COUPLING CLUED TO TANK (TYP.2) INET - OPTIONAL SLIDE SECTION OF 6' PIPE OVER THIS CONNECTION TO PROVIDE SHEER PROTECTION - EXTEND TO BRIDCE EXCAVATION AdvanTex" Treatment System AX20 - Mode la b R 40x94Pod O= Plill FLTRATE AX20 dF �eROGCK d I, 4 BEDROOM : I FIBERGLASS ADVANTEX TANK TO PROPOSED DRAINFIELD 30 NCH BIOTUBE SCREENED VAULT EFFLUENT PUMP e. .. .,. ALASKA N I ER & WASTEWATER ""—~-- -�-- CONSULTANTS, INC. 6901 DEBARK ROAD. SUITE IB • ANCHORAGE. AN 99304 • PHONE (907)357.6170 •FAX (907)338•37L6 11/7/2002 o F app .` ........ . .. C144 oo V�-0� O 4 ........... ... .. ...... Q '•, ff e.. arnes C 795 D�ppOp �OfOsslo a O0000� DRAWN BY:v� C.J.G. Ste. N.T.S. PREPARED FOR: PHONE NUMBER: DEBRA BRITT (907) 258-2000 PAGE NUMBER: 3 OF 4QO LEGAL DESCRIPTION: BRITT SUBDIVISION; LOT 227A, TYPE OF WORK: DETAIL DRAWING OF ADVANTEX TREATMENT SYSTEM THE DISTRIBUTION LINE IS TO BE 1.25 INCH PVC WITH 0.25 INCH HOLES SPACED EVERY 10 INCHES ON CENTER 30 HOLES TOTAL Mi -----------------------------------------� FROM ADVANTEx I O SYSTEM I 5 FEET II WIDE ---------------------------------------MTj 30 FEET LONG �.5. OF EFFECTIVI 2' OF M.OA APPROVED SAND FILTER MT �-5' GRADE INSULATION FILTER FABRIC GRADE THE DISTRIBUTION UNE IS TO BE 1.25 INCH PVC WITH 0.25 INCH HOLES SPACED EVERY 10 INCHES ON CENTER 30 HOLES TOTAL 'err , 11/7/2002 o4 c .... ....... ___:.::. '..`_... DRAWN BY: ALASKA NVATKR & NVASTENAT.KR C.J.G. I NSULTANTS, INC.—SLUE: 6901 DFRARR ROAD. SUITE 20 • ANCHORAGE. AK 99504 • PHONE (907)337.6170 • FAX (907)338.3266 N.T.S. . . . . . . . . ... . . . . . ' . . . . . Q PREPARED FOR: PHONE NUMBER: PACE NUMBER: DEBRA BRITT (907) 258-2000 4 OF 4fr f e s's.:.... Q a OO u E 7953 LEGAL DESCRIPTION: BRITT SUBDIVISION; LOT 227A 44� ^eypc� 60� r TYPE OF WORK: DETAIL OF PROPOSED DRAINFIELD 5slO(\ Q� ALASKA. WATER & NNIASTKVVATKR '�'•"- CONSULTANTS. INC.---"---•-------- -- 6901 DEShRR ROAD. SURE 28 • ANCHORAGE. AK. 99504 • NE- (907)337-6119 • AX: (907)33a-3246 • WEBSIM ok"wc.c SOIL BOG — PERCOLATION TEST LEGAL DESCRIPTION: BRTIT SUBDIVISION; LOT 227A. PERFORMED FOR: DEBRA BRITT DATE: 11/5/2002 DEPTH ORGANICS (feet) --- TEST HOLE 2 1 LOAM 2 3 4 N 7 8 11 12 13 14 15 16 17 18 DEPTH TO GROUNDWATER DATE SEEPS ® 4' k 6' 11/5/2002 5.75' 11 /8/2002 5. 7 200 10 - 6" 2" 6" 2 112* - 4- - 3 1 2" _5:05 - _5-15 - 5:15 _ 3 4 mumWIN111111111 10 ,e7zog 5 5:25 - 6" - MORd 5:35 10 3" 3- 7 5:35 - 6- - r r� 5:45 10 3" DEPTH TO GROUNDWATER DATE SEEPS ® 4' k 6' 11/5/2002 5.75' 11 /8/2002 5. 7 200 10 - DATE READING CLOCK T! NET TIME \U :`% WATER LTE! N -7T r)-700 11/6/2002 1 10 - 6" 2" 6" 2 112* - 4- - 3 1 2" _5:05 - _5-15 - 5:15 _ 3 4 5:25 10 5 5:25 - 6" - 6 5:35 10 3" 3- 7 5:35 - 6- - 8 5:45 10 3" 3" 9 5:45 - 6" - ----- 10 5:55 10 3" 3- 11 5:55 - 6" - 12 6:05 10 3' 3- 19- PERCOLATION RATE 3.3 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 1.0 FT. AND 1.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: 0 YES ❑ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: ROB CAMPBELL COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS AS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:I/j/0102 Municipality of Anchorage ..;, Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.enchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 018-332-27 Permit Number Sw020370 Property owner(s) DEBRA BRITT Day phone 258-2000 Mailing address (1) 3540 DORA AVENUE * ANCHORAGE. AK Mailing address (2) Legal description (Lot, Block & Sub'd.) _ LOT 227A: BRITT SUBDIVISION Legal description (Section, Township & Range) N/A Lot Size 4 q45"0 Acres19D THIS APPLICATION IS FOR: Zip Code 99516 Number of Bedrooms 4 Sewer Only ❑ Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade 0 THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. ALASKA WATER & WASTEWATER CONSULTANTS, INC. Permit Fees: � LI D D Date of Payment: ^^ 21 Receipt Number: _ a1 l D 4 Waiver Fees: Date of Payment: Receipt Number. ALASKA WATER & WASTEWATER CONSULTANTS, INC. September 26, 2002 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 Ref: Proposed Septic System Upgrade for Lot 227A; Britt Subdivision ADVANTEKT"I TREATNIENT SYSTEM To whom it may concern: 1. GENERAL: The existing 4 bedroom home is served by a private well and septic system. The septic system is completely surcharged and must be upgraded. A test hole was excavated on the property. We are proposing to design the septic system around the 30 foot radius of this test hole. Due to high ground water and limited amount of receiving soils, we are proposing to use an Advantex treatment system and a 5 -wide trench type drainfield. 2. SOILS: See the attached log, which shows the soil classifications, groundwater monitoring, and the percolation test results. 3. DRAINFIELD APPLICATION RATE: The intent is to install an Advantex treatment system that will allow the use of a small drainfield in the area around the 30 foot radius of the test hole. A percolation test was performed in the test hole between the depth of 6.2 to 6.7 feet and the rate was 20 minute/inch. The Advantex system has received class III approval and we are going to conservatively assume an application rate of 3.0 GPD/FT2. 4. TRENCH DESIGN: a. Percolation Rate: 20 minutes/inch b. Proposed Application Rate: 3.0 GPD/112 (4.0 GPD/ FT' allowable application rate) c. Number of Bedrooms: 4 d. Design Flow: 600 gallons per day e. Minimum Absorption Area: 200112 f. Total Depth: 3.0 feet (max. at any point) g. M.O.A. Approved Sand Filter Depth: 1 foot h. Effective Depth: 0.5 feet i. Width: 5 feet j. Minimum Length: 40 feet long k. Effective absorption area: 200 i12 6901 Debarr Road, Suite 2-13 * Anchorage, Alaska 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com 5.ORENCO PACKAGE SYSTEM: The STEP tank with the Advantex Treatment System will be manufactured by Anchorage Tank & Welding to meet the latest design criteria established by Orenco Systems, Inc. The point of contact at Anchorage Tank is Lowell McNutt. As with their standard STEP tank, it is equipped with a high water alarm per M.O.A requirements. 6. SURFACE NVATER: There is no surface water within 100 feet of the proposed septic system upgrade. 7. TOPOGRAPHY: The average slope in the area of the proposed drainfield area is <15% slope, in short there are no slope concerns. 8. CLOSING: I am open to any suggestions from your department that would be an improvement to the proposed system. I am unaware of any negative impacts that this installation would impose on adjacent wells, or septic systems. If you have any questions, please call us at 337-6179. P.E., M.S. NOTE: Attached is a site plan drawing, a design drawing, an Advantex detail, a trench detail, a soil log, and a 7 page construction specification letter which are all part of the design package for this septic system. 6901 Debars Road, Suite 2-13 " Anchorage, Alaska 99504 Ph: (907) 337-6179 • Fax: (907) 338-3246 • Website: akwwc.com I I -- T12N, R3W, SECTION 33; I 1 LOT 214 I I I I I 1------- -------------- ------------------ DORA AVENUE ------------------------------- r�__________ I I KENAI VIEW S/D; I E%ISTING 4BEDROOM HOUSE LOT 3 1;. DUSTING SEPTIC SYSTEM ,q ..�. ;� r / a... y4,�.• Y.. ,., c• \ i / ---I .::.:•,- /I BRITT S/D; % T12N, R3W, SECTION J3; --t--'—'— LOT 227B LOT 226 i I I I TMs_-�' � KENAI VIEW S/D; LOT 6 -----------1 \ \ I � �wnn wc(( aenuit PROPOSED SEPTIC UPGRADE -------- _J (SEE DESIGN PACE 2 OF 4) I I L I I I I I T12N. R3W SECTION 33; / T12N, R3W. SECTION 33; I I LOT 245 \ � LOT 245 I 1 I I I I I I I I DATE: 9/26/2002O F •%..._.. DRAWN BY: Z.T.G. _— . _ ..__• _..' -- — - - ( ALASKA NVATIJR & WAS TENVAT.LR SALE CONSULTANTS, INC. 6901 DERARR ROAD, SUITE 28 •ANCHORAGE. AK 0930E •PHONE (907)357-6I79 • FAX (907U38.321.6 1 " = 100, ,....... PREPARED FOR PHONE NUMBER: PAGE NUMBER: �? DEBRA BRITT 258-2000 1 OF 4 A. "" """"�' 4��1 E-795 ess: • LEGAL DESCRIPTION: BRITT SUBDIVISION; a ^G? LOT 227A ' ......••'a��`y ' Professio� TYPE OF WORK: PROPOSED SEPTIC SYSTEM UPGRADE 4nn a— �.,�Z� ;�, %, — — — — — --------------------- — — — — — — — — — — — — — - - - NOTE: THE CONTRACTOR SHALL HAVE ALL WELL RADII SHOWN, i FLAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION -D lrA(znsbns •'-.-••:::; dot•\M•o- / ; . � ;:.:..', �:•:',. ,.•;':;. �..:..• ., • ; A lase onitlAijov- For- ' ..: -�, :;• - ..;.. •.. ,,.•.:. ring •,! •.0 •. .,..J •�..r••.. tom•'•• •'.. /�; t .y.. ... •y I Ir EXISTING FOUNDATIONOG`ri 4 I CLLEANOUT I EXISTING SEPTIC TAN I / TO BE COMPLETLY EXISTING ABANDED PER UPC ` WELL / g� \ d REPAIR SUMP PIPE--,,,\ / EXISTING DRAINFlELD \ } TO BE ABANDONED IN PLACE FOR POSSIBLE / FUTURE USE \ O \ PROPOSED DRAINFTELD. EXCAVATE A TH/1 TRENCH THAT IS 3 FEET DEEP MAXIMUM BY 5 FEET WIDE BY 40 PROPOSED 1500 GALLON / ' FEET LONG. ADD I FOOT OF M.O-A- APPROVED SAND FILTER THEN ADD ADVANTEX FIBERGLASS S.T.E.P. TANK. (SEE - - - - - - ► 0.5 FEET OF CLEAN, WASHED DETAIL PAGE 3 OF 4)— SEWER DRAINROCK. (SEE DETAIL PACE 4 OF 4) / DATE: dDO � 9/26/2002Op F p�'`�......... 04 DRAWN BY: - - - - -_ -- Z.T.G. ALASKA WATER & WASTEWATER SCBE CONSULTANTS, INC. 6901 DEBARK ROAD. SUITE 28 • ANCHORAGE. AK 99504 • PHONE (007)}57.6179 • FAX (9071338-324.6 = 40! :-9�p0 Q D Q PREPARED FOR: PHONE NUMBER: PACE NUMBER: DEBRA BRITT 258-2000 2 OF 4ff y A. G me Qa LEGAL DESCRIPTION: 9� 795 eaOv BRITT SUBDIVISION; LOT 227A 4 .f ..... TYPE OF WORK: PROPOSED ADVANTEX SEPTIC SYSTEM UPGRADE 4�C �oo� �04pp000� NOTE: JIU CROSS, P.E. HAS THE ADVANTEX MANUAL INLET _ AdvanTex" Treatment System AX20 - Mode l a "�x94Pod D'"'�S7 NOTE: THE BOARD INSULATION TO BE INSTALLED OVER THE SEPTIC TANK do 4' BEYOND ON ALL SIDES EXCEPT UNDER THE ADVANTEX FILTER. THIS WILL ALLOW FOR HEAT TO ESCAPE FROM TANK Ac RISE TO THE FILTER ABOVE R. FINAL GRADE— 6• ,,(T CAP— 6' PVC PUMP—OUT—_l�, (TYP.2) 6• PVC COUPLING CLUED TO TANK (TYP.Y) If INLET OPTIONAL SLIDE SECTION OF 6' PIPE OVER THIS CONNECTION TO PROVIDE SHEER PROTECTION— EXTEND TO BRIDGE EXCAVATION 30 INCH INSULATED DRAINFIELD ALASKA «'ATRR & WASTE NVATI CAR CONSULTANTS, INC. 901 DFOARR ROAD. SUITE 28 • ANCHORAGE. AK 99504 • PHONE (907)337-6179 • FAX (907)338.32& SPARED FOR: PHONE NUMBER: DEBRA BRITT (907) 258-2000 ;Al DESCRIPTION: BRITT SUBDVISION; LOT 227A 'E OF WORK: DETAIL DRAWING OF ADVANTEX TREATMENT UNIT DATE: 9/26/2002 DRAWN BY: Z.T.G. SCALE: N.T.S. PAGE NUMBER: 3 OF 4 r,*,5 Grnss: `Jo� MT -O------------------------------------c, -(}- FROM 5 FEET ADVANTEX I O I WIDE SYSTEM C0 -----------------------------------------I MT 40 FEET LONG FILTER 1 FOOT OF M.O A. APPROVED SAN. D FILTER 5' 2+ FEET OF ALASKA WATER & WASTE NVATER CONSULTANTS, INC. 6901 DFSARR ROAD. SUITE 28 • ANCHORAGE. AK 99504 • PHONE (907)337.6179 • FAX (007)33"2L REPARED FOR: PHONE NUMBER: DEBRA BRITT (907) 258-2000 LEGAL DESCRIPTION: BRITT SUBDIVISION; LOT 227A TYPE OF WORK: DETAIL OF PROPOSED DRAINFIELD FINAL GRADE 31 1 5 FEET OF EFFECTIVE DATE: 9/26/2002 DRAWN BY: Z.T.G.SCALE:N.T.S. ova. PAGE NUMBER: 4OF4 DEEP ORN 7953 7 ei ALASKA WATER & MSA - - ____ __... _ _ ...._ __ _ _. o <`• 5,44 ..._ STKWATKR �,'�• 4 .'f�00 CONSULTANTS, INC. . 690 OAS. 29 • u+aanAc 90504 •(907)337-6179 • N(907)3W-3248 • • o wwe.eom ..... .. . . .. ... . ........Q SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: BRfTT SUBDNISION; LOT 227A .Je f• A. Offl SS; Q PERFORMED FOR: DEBRA BRITT Q J '• —795 DATE 9/13/2002 1�.0 DEPTH4sie�''••.....•• (feet) TEST HOLE 1 ��DO00000��� ORGANICS ==== SOIL CLASSIFICATIONS 2 " GW — ORG 3— LSF GP ML GM CL q GC OL ° o SW MH 5 �'• : SP CH SM OH g Sc 7 DEPTH TO 8 ML 9 HARDER DIGGING w/ DEPTH SITE PLAN 10 11 DATE READING CLOCK NET TIME WATER LEVEL NET DROP 12 13 3 1:15 — 6" — 14 15 6 2:15 30 4 1/2- 1 1/2- B.O.11. 16 17 16 19 PERCOLATION RATE 20 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 6.2 FT. AND 6.7 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: E YES ❑ NO SOILS LOGGED BY: KELLY HEITSTUMAN PERCOLATION TEST PERFORMED BY: MATT FISHER COMMENTS: PERFORMED BY AKWWC. INC. Ir JEFFREY A. GARNESS, CERTIFY THAT THIS W PE ORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: Z 0�1 GROUNDWATER DATE DRY 9/13/2002 DRY 9/17/2002 7.5' 9/25/2002 12:45 — TIME (MINUTES) READING (INCHES) 9/17/2002 1 12:45 — 6" — 2 1:15 30 ♦.{.J wry .. 1 11 16" I 4 1:45 30 4 1 2" i 5 1:45 — g" — 1 =100 TIME (MINUTES) READING (INCHES) 9/17/2002 1 12:45 — 6" — 2 1:15 30 4 5 16" 1 11 16" 4 1:45 30 4 1 2" 1 1 2" 5 1:45 — g" — Municipality of Anchorage Development Services Department *1E Building Safety DivisionOn-Site Water and Wastewater Program4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: ALASKA WATER 6 WASTEWATER CONSULTANTS INC Legal description: 0RI1T SUBDIVISION LOT 227A The attached paperwork has been reviewed and is being returned for the following reasons: ❑ Original signature or stamp missing on ❑ Calculation error in design. ❑ Additional soils information needed. ❑ Water !monitoring results inadequate. ❑ Discrepancy in information submitted. ❑ Topographic information missing or inadequate.' ❑ Incomplete; missing ❑ Incomplete; missing ❑ Additional adequacy test information needed. ❑ Water sample unacceptable. ® Measured/proposed distances/dimensions missing. MISSING ❑ Locations of all soils, percolation and water monitoring tests not shown. ❑ Proposed system too deep for soils information submitted. ❑ Well log required. ❑ Omission in narrative. ❑ Insufficient till over tank or field. ® Other.' EXISTING_ ABSORPTION FIELD MUST BE PERMANEtJTLV nFcnMMTAATnKl=h Municipality of Anchorage Development Services Department Building Safety Division .,. On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 I�-�02 CERTIFICATE OF HEALTH AUTHORITY APPRO AL FOR A SINGLE FAMILY DWELLING Parcel I.D. 018-332-27 HAA# & JZ� �iOZ 1. GENERAL INFORMATION Expiration Date: 3 `1OZ Complete legal description BRITT SUBDIVISION; 227A. Location (site address or directions) 3540 DORA AVENUE ' ANCHORAGE. AK 99516 Current Property owner(s) DEBRA BRITT Day phone 258-2000 Mailing address 3540 DORA AVENUE • ANCHORAGE, AK 99516 Lending agency Day phone Mailing address Real Estate Agent ANITA BATES w/ BATES & ASSOCIATES Day phone 243-8777 Mailing address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Note: Alaska Water and Wastewater Consultants, inc. shall be paid S at, or prior to closing for the engineering services provided. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage riles and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ALASKA WATER & WASTEWATER CONSULTANTS, INC. Address 6901 DESARR ROAD, SUITE 28 ' ANCHORAGE. AK 99504 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, AKWWC, Inc. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. AKWWC, Inc. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any otherperson or party is not authorized. nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for bedrooms. Disapproved. Conditional approval for bedrooms, with the fllowing Phone 337-6179 Date Y OF 'C16 ON-�ITr ,.WATERpNp :vm; PROGR ' ' �J h . . . . n Attachments: HAA Checklist Manitenance Agreements Septic System Advisory Supplemental Engineer's Reort Well Flow Advisory Other By. Original Certificate Date: I (Rev. 12101) Municipality of Anchorage Development Services Department! == ` ... R Building Safety Division i On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cf.anchorage.ak.us (907) 343-7904 I HEALTH AUTHORITY APPROVAL CHECKLIST I Legal Description: BRITT SUBDIVISION; LOT 227A Parcel ID: 018-332-27 A. WELL DATA Wella PRATE typ If A. B, or C provide PWSID# ' N A Well Log (Y/N) ILA Date completed 8/28/79 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES II Total depth 135 ft. Cased to 40+ ft. Casing height (above ground) 12+ in. II FROM WELL LOG AT. INSPECTION Date of test 8/28/79 8/28/2002 i Static water level , UNKNOWN II Well production 6m. 3.25 9 P g.p.m. I II WATER SAMPLE RESULTS: i� Coliform 0 colonies/100 ml. Nitrate :0.222 mgJL. Other bacteria 9 colonies/100 ml. Arsenic: �mg./L Date of sample: 8/28/2002 Collected by: AKWWC, INC. B. SEPTIC/HOLDING TANK DATA ADVANTEX TREATMENT SYSTEM Tank Type/Material FIBERGLASS Date installed 11/12-18/2002 Tank size' 1500 gal. Number of Compartments 2 Cleanouts i(Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) YES i Date of pumping NEW Pumper C. ABSORPTION FIELD DATA 10BELOW Fiwu cru�E Date installed 11/12-18/2002 Soil rating p.d./f r ft=/bdrm) 6_0 Sysfem type TRENCH Length 30 (2 ® 15) ft. Width 5 - ft. Gravel below pipe 0.6 ft. I I� Total depth •les—as2ft. Eff. absorption area 150 ft' Monitoring tube YES I Depression over field NO Date of adequacy test NEW Results (Pass/Fail) — For 4 bedrooms Fluid depth in absorption field before test in. Water added P gat. New depth =in. Elapsed Time: min. Final fluid depth _ in. Absorption) rate >_ — g.p.d. Ii Any rejuvenation treatment (past 12 mo.) (Y/N &type) — ! If yes, give date II 'r is i, II D. LIFT STATION / PUMP VAULT Date installed 11/12-18/02 Size in gallons 1500/45 Manhole/Access (Y/N) YES TIMER/ TIMER/ "Pump on" level at 32 in. "Pump off" level at 22 in. High water alarm level at 46/36 in. Datum BOTTOM OF TANK Cycles tested NEW Meets alarm & circuit requirements?--)LS— E. equirements?YESE. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main N/A Public sewer manhole/cleanout N/A Sewer /septic service line 25'+ Holding tank N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: '+ Absorption Building foundation 5'+ Property line 5field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line •5'+ Building foundation 101+ Water main N/A P Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS •vrRAAI 5' IAT 1 INF GRANTFD AY DAN ROTH ON 11/8/.2002 G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA NAA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date rL f 2S oY HAA Fee $ 375. Date of Payment 17--?--02— Receipt 17--2-'02Receipt Number 2 (Rev. 12/01) 0 oo . . .. J f re Gar 953 ,•' `c�°oO A �46k P— fe9910P��o Waiver Fee $ 1,50---- Date S0•—Date of Payment j '2- �� 2 ^0z - Receipt Number ?--974r• $ 1/4r• I SEP -03-02 02:56PM FROi1-CUE ENVIRONWNTAL SRV 'AG ME Environmental Services Inc. lla\. W"AW""W.WWAW/.IIWI.IIr CUE Ref.# 1025558001 Client Name AK Water & Wastewater Consultants Inc. Project Name/# Britt L 227A Client Sample ID Britt L 227A Matrix Drinking Water Ordered By PWSID 0 Sample Remarks: 9075615301 T-219 P.02/03 F-844 All Dates/Times are Alaska Standard Time Printed Date rime 09/03/2002 8:39 Collected Datelrime 08/28/2002 10:02 Received Date/time 08/28/2002 13:20 Technical Director_ Stephegr2".91, de Released By e/�,�1/,�,,� q� j` Allowable Prep Analysis Panmcter Results PQL Units Method limits Date Date Init Waters Department Nitrate -N 0.222 Microbiology Laboratory Total Coliform 9 OB, No Coli 0.200 mg/L EPA 300.0 (<=10) 08/28/02 !DT col/100mL SM189222B (<=j) 0828/02 KAI TIESZEN AVENUE D❑RA AVENUE 3' R.O.V. EASEMENT \ Q ILA o71 ��-• d 10' UTILITY EASEMENT m cu co ASPHALT PARKING AREA LOT 227 B � r � P W TWO STORY FRAME BU(LDINP, Alp P 2 GRAVEL DRIVEWAY O CD A d f �1 O 1 Z It S S FILTER `UFT- ....,._.. _.-• STATION STATION S S S 10' UTILITY EASEMENT OF A t%' k4p * 91H............*. .............:..` SHANE A. HOLT LS -6914 4�� •..len•, `•ao THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY CONFI EXISTING STRUCTURES AND PLATTED LOT LINES OR EASEMENTS AND IS NOT TO BE USED FOR POSITIONINI STRUCTURES OR FENCEUNES. EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED PLAT, ARE NOT SHOWN HEREON. NOTE: ANY FENCEUNES SHOWN ARE LOCATED APPROXIMATELY AND ARE NOT TO BE USED TO DETERMINE OR LOCATE STRUCTURES. N t57"JU-CfU"W 1b4, AS -BUILT SURVEY NO CORNERS SET THIS DATE — I HEREBY CERTIFY THAT I HAVE PERFORMED A MORTGAGEE'S INSPECTION OF THE FOLLOWING DESCRIBED PROPERTY. LOTS 227A AND 2278, BRITT SUB. ANCHORAGE RECORDING DISTRICT, ALASKA AND TH T PROVEMENTS SITUATED THEREON ARE WITH N TY LINES AND NO VISIBLE ENCROACHMENT THAN NOTED. DATED AT ANCHORAGE, ALASKA THIS 29TH----- - C O 0 O m ,SIJ1 RightFAX 12/3/2002 5:24 PAGE 1/1 RightFAX 0'l'0:3 9v Inspection Report Municipality of Anchorage, Building Safety Division 4700 South Bragaw INSPECTION: VOICE 343-8300 INSPECTION: FAX (907)249-7777 INFO: 343-8211 Name RISING SUN Permit 02-9619 Address 3540 DORA AVE Phone 250-1100 Legal LT 227A Inspection Date 12/4/2002 Subdlvlslon BRITT Comments or Directions SEPTIC SYSTEM REIN CALL B-4 TO FIND IT THIS TIME Inspectlon Retro Electrical Reinspection N NO NONCOMPLIANCE OBSERVED ❑ CORRECTIONS ESSENTIAL AS EXPLAINED BELOW WILL RE-EXAMINE AT NEXT ❑ DO NOT CONCEAL UNTIL REINSPECTION INSPECTION COMMENTS: (far inspector use only) 1 Inspector --� %•' i�'I� Date: y