HomeMy WebLinkAboutSOUTHPARK #2 BLK 1 LT 25Municipality of Anchorage Page 1 of 3 Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW030127 PID Number: 020.052.25 Name: Wastewater System: New Bob Stevens Address: 7541 Our Own Lane Anch., AK 99516 ABSORPTION FIELD Phone: Number of Bedrooms: Deep Trench 301.1366 Four 4 Sod Rating: Total Depth from original grade: LEGAL DESCRIPTION 1.2 GPD/F? 12 Ft. Block: Lot: Subdivision: Depth to pipe bottom from onglnal grade: Gravel depth beneath pipe: 1 25 South ark Bluff No. 2 3 Ft. 8 FL Township: Range: Section: Fill added above onynal pada: 0.1 Gravel Length: 35 Ft. Ft. Gravel width: Numom of lines: Distance between lines: Well: Class A Community 4 Ft. 1 I Ft. Classification (Private, A. B. C): Total Depth: Cased to: oral absorption area: 560 Pipe Material: ASTM 3034 PVC Fe Driver: Date Drilled: Static Water Level: Ff nstaller; Red Dog Masonry to stave : 711812003 Yield: n.r I Pump Set at: Casing Height Above Ground: r. TANK SEPARATION DISTANCES® Septic ❑ Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption Lift Holding ublictPrivate Manufacturer: Anchorage Tank Y 11250 From Tank Field Station Tank Sewer Line Material: u ero onpanmen s: >200' >200' NIA NIA >25' Steel Two (2) Well >100, >100' NIA NIA LIFT STATION — NONE ON LOT Surface Water LotUne >5' 4' NIA NIA Gal. lvunulacluler. ump on eve a . Fumpolt levela .ig wa er a,arm at. Foundation >5' >10' NIA NIA In. In. in. Pump Make 8 Model Electrical Inspections performed by: Curtain Drain None Noted Remarks: BENCH MARK See Lot Line Waiver. Location and scrip on: Garage Slab ASSUmd LIeVat,W: 100.0 Ft. Engineer's Stamp •• ( �1 ,. Inspections performed by: MEA Dates: 16t 711812003 ;.'49th �to0..'.. . 2nd 711812003 i._ .... ... ............................ ... � �� �E. Department of Hea t and Human Services approval A 1 MICHAEL ANDERSON .' W r, 0 �'.J NO. CE -4381 � Date: z 2 0 ,' ����fpfD ............. 'P�```•�•• Reviewed and approved by: 44 %FESS'k (Rev. 101") Municipality of Anchorage Page 2 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: SW030127 PID No. 020-052-25 N x757'24-E 170.63' 33' SECTION UNE ESWr. --------------------------------------------------- A B S1 18.3 28.4 S2 22.5 31.6 C4 34.0 20.6 M1 57.5 48.9 C5 60.2 50.9 �p s1 S2 C N N N ^I W1 ii Four Bedroom Home C4 N 'o C5 0 wig TH2 Alternate Site A.C. DRNE a 4 nn k�Eydr. 0604• RAS\3.76' i L�\ (� O, SOVtNPAR�f DRIVE 49th �.... i .... ........ti.....t PLAN AS-BUILT MICHL ...RD*E::::: ��'; AEE. ANDESDN � No. EE-438I ,•,�� SCALE 1' 30' �j♦ •.. l.:r Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: SW030127 N `100.45 y U U 1,250 PID No. 020-052-25 N _In U f SU PROFILE AS -BUILT - Scale: I"= 10' ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 (FAX) December 1, 2003 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 25, Block 1, Southpark Subdivision No. 2 Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: The septic system on Lot 25, Block 1, Southpark Subdivision No. 2 was inadvertently placed within 4' of the east property line. The lot lines were not clearly marked during construction and the end of the trench was mistakenly placed within the 10' of the property line. We are therefore requesting a waiver be granted allowing the trench to be at 4' from the eastern line. A majority of the new trench will be a minimum of 10' from the lot line. The subdivision is currently served by a public water system and no wells are located within 200' of the absorption trench. Placement of the new absorption trench at the existing location does not impact wells or adjacent septic systems. We therefore recommend a waiver be issued allowing the new trench to be constructed at 4' from the east property line. Sincerely, Y41tt,l E4a� Michael E. Anderson, P.E. V .49th )K' * MICHAEL E. ANDERSCN ._ No. CE -1781 y Permit Number: SW030127 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial 7A� ►ONS Z; I T? (.V, Date Issued: May 14, 2003 Expiration Date: May 13, 2004 Parcel ID: 020-052-25 Legal Descri tion: 'SOUTHPARK #2 SUBDIVISIO.... LO g p CK 1 LOT 25 a Le Design Engineer. 0014 Anderson Engineering Owner Name: BOB STEPHENS Owner Address: 4731 SOUTHPARK BLUFF DRIVE ANCHORAGE, AK 99516 - Site Address: 4731 SOUTHPARK BLUFF DRIVE Lot Size: 22729 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: F✓ Disposal Field Z✓ Septic Tank E] Holding Tank E] Privy Private Well E] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Ibi Date: Lo,,7 Date: �� Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWERNVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 020.052.25 Permit Number SW O 10 / Z 7 Property owner(s) Bob Stephens Day phone 301.1366 Mailing address (1) 7541 Our Own Lane Anchorage AK 99516 l3 a4in 3/ 9 95-/6 g address (2)4%SOuTI�PI�l41t �uf� DR�v� Zip Code Legal description (Lot, Block & Sub'd.) Lot 25 Block 1 Southpark Subdivision Addn. No. 2 Legal description (Section, Township & Range) Lot Size 22,729 Acres/Sq.Ft. Number of Bedrooms Four (4) THIS APPLICATION IS FOR: Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. �, V-c� (Signature of property owner or authorized agent) Permit Fees: 4cD Waiver Fees: Date of Payment: �;-- Date of Payment: Receipt Number: Receipt Number: (Rev. 12/00) Ulu ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX May 7, 2003 Municipality of Anchorage Development Services Department On -Site Wafer and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 25, Block 1, Southpark Subdivision No. 2 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 25, Block 1, Southpark Subdivision No. 2 intends to construct a new four-bedroom home on the lot. The subdivision is currently served by the Municipal water system. We are therefore requesting a permit be issued for the construction of a new septic system to serve the home. The attached Site Plan and backup documentation identify the location of and configuration of the new septic system and alternate site and the parameters used in the design. Also identified on the plans are the test hole locations and the septic systems on the surrounding lots. Drainage arrows and spot elevations are shown indicating the current drainage patterns. The drainage patterns will be maintained after construction. The test holes placed near the location of the proposed absorption trench and alternate site indicated clean sand with some gravel and varying amounts of silt and percolation rates approximating 2 to 5 minutes per inch. No ground water was found during placement of the test holes and none was noted during the monitoring period. We are therefore proposing to place a 1,250 -gallon septic tank and a 35' long x 3' wide x 8' effective depth absorption trench. The distribution pipe will be placed 3' below the existing surface and the total depth will be 11'. Sufficient fill will be placed over the septic tank and absorption trench to prevent freezing. The ground surface on the lot slopes as shown on the site plan from north to south at varying slopes. The back of the lot slopes steeply to Rabbit Creek. The absorption trench will be constructed at the front of the lot parallel with the slope as much as possible in conformance with Municipal requirements. All components of the new Lot 25, Block 1, Southpark No. 2, . May 7, 2003 Page Two septic system will be constructed a minimum of 100' from any surface water and 10' from the water service line on the lot. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The subdivision is currently served by the Municipal water system. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, 7I/kjt Michael E. Anderson, P.E. Attachments r iK f . -vd .49th .1* M CHAEL E. Av:)i.?:Ota No. CE -4381 - �i.............. • n��E55�J��� •�• Vacant - Stope to Rabbit Creek 175.91 170.88 4281 9289 a � Nea VVVVVV$ 27fp -3k 24 Ii r� N "P N Sapb�Wa 87.95 7 23 1,7 9 �`7d 6F' 120Op 110.76 �7 J bb � 114 15 T/ J b. 13 s' 2 O�J� S66 `506 12 CJ 16 Na >~ NA 00'1TENa70 f� 26A.95 7 •`C _ ` • r 11 17- 10 �` 18 0 JJ svb,, 7BgJ 5y1M1 7°J�7g y `y ' M1 9 m vm 7°J 19 . 1M1 M156 •.?P...... AREA MAP =° 49th _ '•� ;._.. 0 SCAM 1 low ��A MIGNELE."DERSD,1 No. CF4WSi ��,,' ..gyp • 1O—V 83-213 SOUTHPARK SUBDIVISION, ADDN. NO. 2 LOT 25 BLOCK 1 22.129 S.F. N 33' SECTION UNE ESMT. 5/8' REDN2 M PER RELATIVE ELEVATION FROM ASSUMED DATUM 100' SITE • 6 I ' I I I I I I I Four Bedroom Home I �1 I I I I I FlN. FLR. EL. - 110' 18• 1.250 canon sr I Se tic Tank I sa TH 16.; A.C. DRUE T' c 35' Long ■ 3' Wide z S' a Effective Depth Absorption Trench N • Alternate ite C 0 • TN 1® 10 T. & E. ESW. �� _.. a•313.T6 O_ SDUSNpPR' D PLAN SCALE 1 Is = 30' LOT 25, BLOCK 1, SOUTHPARK SUBDIVISION NO. 2 DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Deep Trench System Perc. Rate: 4 Min./Inch 1,250 Gallon Septic Tank Application Rate: 1.2 GPD/SF 8' Drainfield Rock 4 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 500 SF Absorption Area 500 SF/16 SF/LF = 31.25 LF Trench Length THEREFORE: Construct a 35' Long x 3' Wide x 8' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth to be 11' Below Existing Ground. Maintain 10' Separation From Water Line on Lot. Place 2' of Direct Bury Insulation and 2' of Fill Over Absorption Trench or Provide Minimum 3' of Cover to Prevent Freezing. 4' of Cover Over Septic Tank. Natural Backfill 2'6" Geotextile Fabric 6" 4" Perforated PVC (Holes Down) 810" I I �— Drainfield Rock 3' TYPICAL DEEP TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF BUILDING SAFETY/ON SITE WATER AND WASTEWATER PROGRAM 4700 BRAGAW STREET, ANCHORAGE, AK 99502-0605 SOILS LOG - PERCOLATION TEST PROJECT #: M0314 PERFORMED FOR: Bob Stephens DATE PERFORMED: 5/1/03 LEGAL DESCRIPTION: Lot 25 Block 1 Southpark Subdivision No 2 j� TEST HOLE # 1 SLOPE IIIIIIIIII PT/OG I / I 2 3 4 5 `. 6 ,r.. 7 g :. t 10-1 0 i r 11 .. •yam 12- 13-- 14- 15- 4 21315 .. 16- 17 6 17 > 10% 1 N MEDIUM COMPACTED WELL GRADED SANDS WITH GRAVELS & LITTLE FINES - SW WAS GROUNDWATER ENCOUNTERED? NO IF YES, WHAT DEPTH? DEPTH OF WATER None AFTER MONITORING: DATE: 5/7/2003 i (:q' 9th :...:. ...... ....... ............ 1,,'y WHARE AMXRSCN . �:, No. a-4781 ••• 4 41 0"ROF �S����v 80H L 0 P E SITE PLAN See Site Plan N 2-5% READING DATE GROSS TIME NET TIME DEPTH OF WATER NET DROP Start 5/1/03 5:15 10" 1 5:45 30 1.25" 7.75" Recharge 5:46 10.25" 2 1 6:16 30 2.S" 7.75" Recharge 6:17 10" 3 6:47 30 2.375" 7.625' FERC RATE: 4 MIN./INCH PERC. HOLE DIAMETER: 6" TEST RUN BETWEEN 4.5 FT. AND S.5 T. COMMENTS: Test Hole Presoaked Prior to Test. TEST PERFORMED BY: MIKE ANDERSON I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 5/7/2003 2 3 4 5 6 7 8 9 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF BUILDING SAFETY/ON SITE WATER AND WASTEWATER PROGRAM 4700 BRAGAW STREET, ANCHORAGE, AK 99502-0605 SOILS LOG - PERCOLATION TEST PROJECT #: M0314 PERFORMED FOR: Bob Stephens DATE PERFORMED: 5/1/03 LEGAL DESCRIPTION: Lot 25 Block 1 Southpark Subdivision No 2 2 SLOPE SITE PLAN � �p TEST HOLE # IIIIIIIIII PT/OG I / I 10% NO 10 • .• •: IF YES, WHAT DEPTH? DEPTH OF WATER 4 Start 5/1/03 5:20 "• DEPTH OF WATER II : •+'+� None AFTER MONITORING: 30 • �•: ''r: • DATE: 5/7/2003 Recharge 5:51 MEDIUM COMPACTED 10.25" WELL GRADED SANDS "';�;:•;•' WITH GRAVELS & LITTLE FINES - SW .r 1.5" 8.75" Recharge �.::• •.. WAS GROUNDWATER -7 ENCOUNTERED? ENCOUNTERED? 3 6:52 10% NO 10 • .• •: IF YES, WHAT DEPTH? DEPTH OF WATER 4 Start 5/1/03 5:20 "• DEPTH OF WATER II : •+'+� None AFTER MONITORING: 30 • �•: ''r: • DATE: 5/7/2003 OF 14- 15 .... � 7,�'' •4. ' • • M101AEL L AN"WN ar : y *4o -fR0FfSS0* 17 BOH S L 0 E See Site Plan N 2-5% READING DATE GROSS TIME NET TIME DEPTH OF WATER NET DROP Start 5/1/03 5:20 10.625" 1 5:50 30 1.75" 8.875" Recharge 5:51 10.25" 2 6:21 30 1.5" 8.75" Recharge 6:22 10" 3 6:52 30 1.2S" 8.75" PERC RATE: 2 MIN./INCH PERC. HOLE DIAMETER: 6" TEST RUN BETWEEN 4.5 ' FT. AND S.S T. COMMENTS: Test Hole Presoaked Prior to Test. Same Soil Characteristics as TH 1. TEST PERFORMED BY: MIKE ANDERSON I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 5/7/2003 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 25, BLOCK 1, SOUTHPARK SUBDIVISION ADDN. NO. 2 GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,250 -gallon tank at the location shown on the site plan. Work also includes the construction of a new absorption trench 35' long by 3' wide by 8' effective depth also at the location shown on the Site Plan. The total depth of the trench will be 11' below existing ground and the distribution pipe will be placed at 3' below the surface. All components of the new absorption trench and septic tank must be constructed a minimum of 100' from any surface water or 10' from the water service line on the lot. A minimum of 4' of cover is required over the septic tank and 3' over the absorption trench. In lieu of cover 2" of direct bury insulation and 2' of cover may be placed. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for.final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,250 -gallon septic tank must be procured from a certified septic tank manufacturer if the existing tank is found to be defective. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. Lot 25, Block 1, Southpark No. 2 May 7, 2003 Page 2 of 3 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. Lot 25, Block 1, Southpark No. 2 May 7, 2003 Page 3 of 3 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. Municipality of Anchorage Development Services Department =• o Building Safety Division ."Otis o On -Site Water and Wastewater Program S„ E,. 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 �T www.cf.anchorage.ak.us (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 20.052.25 HAA# keF 30 Expiration Date: /Z & /oy 1. GENERAL INFORMATION Complete legal description Lot 25 Block 1 Southwark Subdivision No. 2 Location (site address or directions) 4731 Southpark Bluff Drive Current Property owner(s) Bob Stevens Day phone 301.1366 Mailing address Lending agency Mailing address Real Estate Agent Mailing Address 7541 Our Own Lane Anchorage AK 99516 Unless otherwise requested, HAA will be held by DSD for pickup. Day phone Day phone 2. NUMBER OF BEDROOMS: Four 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class A Well ® Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an Independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority App -oval 3uidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522.7773 Address _P.O. Box 240773 Anchorage AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date . 12/3/2003 5. DSD SIGNATURE Approved for bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other By: Original Certificate Date: (z z to (Rev. 12M) Municipality of Anchorage • � Development Services Department % Building Safety Division ` ' w 3 [T On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.ahchorage.ak.us (907)343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Lot 25 Block J. So uthpark Subdivision No. 2 Parcel ID: 020.052.25 A. WELL DATA Well type If A. B, or C provide PWSID # _ Well Log (Y/N) Date completed _ Sanitary seal (Y/N) Wires properly protected (Y/N) Totaf depth' ft. Cased to ft. Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft. Well production 9-P.M. 9•P•m• WATER SAMPLE RESULTS: Coliform colonies/100 ml. Nitrate mg./I. Other bacteria colonies/100 ml. Date of sample: Collected by: B. SEPTICIHOLDING TANK DATA Date installed 711812003 Tank Type/Material Septic/Steel Tank size 1.250gal. Number of Compartments 2 Cleanouts (Y/N) Y I, Foundation cleanout (Y/N) Y Depression over tank (YIN) N High water alarm (Y/N) N Date of pumping Pumper New Construction C. ABSORPTION FIELD DATA Date Installed 711812003 Soil rating (g.p.d./ft? or fe/bdrm)1.2 GPDISF - System type Deep Trench I Length 35' ft. Width 4 ft. Gravel below pipe 8 ft. Total depth 12 ft. Eff. absorption area 560 fl? Monitoring tube Y Depression over field N Date of adequacy test Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test in. Water added_ gal. New depth_ in. I , Elapsed Time: _ min. Final fluid depth _ in. Absorption rate >= g•p.d. Any ,rejuvenation treatment (past 12 mo.) (YIN & type) N 'if yes, give date X D. LIFT STATION Date installed "Pump on" level at _ in Datum Size in gallons "Pump off' level at _ in. Cycles tested Manhole/Access (Y/N) _ High water alarm level at Meets alarm & circuit requirements? n E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot NIA On adjacent lots NIA Absorption field on lot NIA On adjacent lots NIA Public sewer main NIA Public sewer manhole/cleanout NIA Sewer /septic service line NIA Holding tank NIA SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Absorption field >5' Water main >10' Water service line >10' Surface water 2100' Wells on adjacent lots >200' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 4' Building foundation >10' Water main >10' Water Service line >10' Surface water >100' Driveway, parking/vehicle storage >5' Curtain drain None Noted Wells on adjacent lots >200' F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 12/11/2003 HAA Fee $,+�A�^- Date of Payment Receipt Number (Rev. 12/00) �aZaaaat�-- ••OP.E, �......, ` 49h .. .. ICHAEL E. ANDERSON ; r •.. No.CE-4381 Ltd • 4n •_ ..`•tf •�urw�w v Waiver Fee $ /S D Date of Payment / Z• — 0,3 Receipt Number in.