Loading...
HomeMy WebLinkAboutGLENN VIEW ESTATES NORTH BLK 3 LT 1Glenn, V iew Estates North Block 3 Lot 1 #051-811-55 Municipality of Anchorage ;•'' `` *Z4 , Development Services DepartmentBuilding Safety Division On -Site Water and Wastewater Program, 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW030142 PID Number: 051-811-55 Name: Troy Davis Homes. Inc. Wastewater System: ® New ❑ Upgrade Address: 1451E. Parks HYN, #207 Wasilla. AK 99687 ABSORPTION FIELD Phone: Number of Bedrooms: U Deep Trench ®Shalkrw Trench O Bed O Mound 13 Other: LEGAL DESCRIPTION Sol Rating: Total Depth from original grade: 0.6 GPD/Ft' 6 Ft. Black: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 3 1 Glenn View Estates North 2.83 Ft. 3.17 Ft Township: Range: Section: Fill added above original grade: Gravel Length: 1.65-2.45 Ft. 118 Ft. Well: ❑ New ❑ Upgrade5.0 Gravel width: Number of lines: Distance between lines: Ft. 1 NA Ft Classification (Private, A. B. C(: Total Depth: Cased to: Taal absorption area: Pipe Material: Public Ft. Ft 1017 Fe D3034 & F810 Driller. Date Driled: Static Water Level: Installer. Date Installed: Ft Mike Cur 9/25/03 Yield:Pump Set at Casing Height Above Ground: TANK GPM Ft. FI SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. O Other: To Septic Absorption Lift Holding Public/PrivateManufacturer; panty: From Tank Field Station Tank Sewer Line Anchorage Tank 1250Gai. Well 200'+ 200'+ NA NA 25'+ Material; Steel Numberof Compartments: 2 Surface Water 100'+ 100'+ NA NA LIFT STATION Lot Line 5'+ 10'+ NA NA Size; Manuldcluref. Gal. Foundation 5'+ 10'+ NA NA 'Pump on level at: 'Pump off level at: High water alarm at: le. m. In. Curtain Dram NA *50'+ NA NA Pump Make & Motlot EleNral Inspections performed by. Remarks: *none known BENCH MARK Location arcaDescription: Bottom of siding Assumed Elevation: 100 FL Engineers Stamp i OF A44 U� 9114 Inspections performed by: KND Engineering. Inc.Dates: 1 9/25/03 Saaa:'.�.•,.a«•,•.a ,� •..•.: • t 2nd 9/29/03 Development Services Department Approval 3"t IlleS163=� • ..aa, ..... , Kennetn7116uf ( /tom q CE F •• Reviewed and approved by: lay,.. Iznnl Date: & t : o •a• .. J � e�\oFES�1�4P.,.•� AS—BUILT SYSTEM DETAILS/SITE PLAN GLEN VIEW ESTATES NORTH S/D, BLOCK 3, LOT 1 EfiE L :`.! Permit SW030142 PID#051-811-55 Bow house \ �R\ ,���s\\ SCALE) V = 50' PREPARED FOR: TROY DAVIS HOMES, INC 1451 E. PARKS HWY, SUITE WASSILLA, AK 99687 FlELD BOOKS COMPUTED: 90'"m' ANG DRAWN: vBG STAMa- NA CHECKED: KMD AMUaT: NA DA1e 11/14 Or- FXE: CMO: Kiun at 118.0' --1 SCALEt NTS 80.6 am ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 ACAD RE' 03028.DWGI ADD "" 03028 1 (907)696-6111 111 8,25 Y 59 A -C= 32.9' ' B -C=17.8' 7-dd A—D= 37.7' B -D= 23.5' 97.08 FINAL GRADE 96.30 A-E= 47.5' L MT"`"'"" B-E = 86.3' 1250 GAL A -F= 83.6' SEPTIC 9183 9182 B -F= 44.3' TANK 'SEWER ROCK air PREPARED FOR: TROY DAVIS HOMES, INC 1451 E. PARKS HWY, SUITE WASSILLA, AK 99687 FlELD BOOKS COMPUTED: 90'"m' ANG DRAWN: vBG STAMa- NA CHECKED: KMD AMUaT: NA DA1e 11/14 Or- FXE: CMO: Kiun at 118.0' --1 SCALEt NTS 80.6 am ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 ACAD RE' 03028.DWGI ADD "" 03028 1 (907)696-6111 111 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water& Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial C� InIO3 -- Date Issued: May 21, 2003 Expiration Date: May 20, 2004 Permit Number: SW030142 Parcel ID: 051-811-55 Legal Description: GLEN BIEW ESTATES NORTH BLOCK 3 LOT 1 Design Engineer: 0070 KND Engineering Owner Name: TROY DAVIS HOMES, INC. Owner Address: NHN WHISPERING BIRCH CIRCLE CHUGIAK , AK 99567 - Site Address: NHN WHISPERING BIRCH CIRCLE Lot Size: 43376 SO. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ❑✓ Disposal Field Fv Septic Tank Holding Tank E] Privy All construction must be in accordance with: 1. The attached approved design. Private Well ❑ Water Storage 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: Date: 5-1211,03 Municipality of Anchorage Development Services Department Building Safety Division o= On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWERNVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 0S/ —18 / / — s.r Permit Number SW U90 /42 Property owner(s) Troy Davis Homes, Inc. Day phone 357.9394 Mailing address (1) 1451 E Parks Hwy., Suite 207, Wasilla, AK 99687 -A4 44"jaddress (2) W H I SPERIUG 81RCH CIRCLE Zip Code 7ZM Legal description (Lot, Block & Sub'd.) Glen View Estates North, Block 3, Lot 1 Legal description (Section, Township & Range) Lot Size -43244- Acre q.Ft. 4 3, 376 THIS APPLICATION IS FOR: Number of Bedrooms 4 Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. of property owner or authorized agent) Permit Fees: Y0-0 Waiver Fees: Date of Payment: s//yl '03 Date of Payment: Receipt Number: 03Sy7,Sr Receipt Number: (Rev. 12/00) U � U KNDD ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-6111 /FAX (907)696-8111 May 14, 2003 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: New sewer permit — Glen View Estates North, Block 3, Lot 1 Gentlemen: The owner has requested we proceed forward to obtain a septic permit on the subject lot. On January 28, 2002 Tobben Spurkland (TS), PE dug one testhole for the proposed system. An additional testhole was performed. on April 30, 2003. The results of these tests are attached. The general slope of this lot is from south to north at a grade of approximately 3-25%—the majority of the lot is relatively flat. As you can see on the attached topo/subdivision testhole data and TS testhole, the legal description on the TS testhole does correspond to the subject lot. The legal description was changed after the testhole was performed. We have designed our system utilizing the existing testholes that were excavated for proposed 4 -bedroom house. The lot will be served by public water. We propose to install one 5' wide shallow trench. Water was not encountered during the excavation, but during monitoring at 11' TS and 12.8' KND. There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, IES"'M Engineering, Inc. K Zn . Duffus, P.E. Attachments: As noted On -Site Well and Sewer Application Wastewater Absorption System Details/Site Plan Soils Log/Percolation Test WELL & WASTEWATER DISP❑SAL SYSTEM DETAILS/SITE PLA GLEN VIEW NORTH S/D, BLOCK 3, LOT 1 DESIGN DETAILS 4 BDRM X 150 GPD = 600 GPD 600 GPD/0.6 GPD PER SO. FT. (8.88 MIN/IN,) = 1000 SQ, FT (1000/5'(W)) X .58(RF) (3.0' GRAVEL) = 116 FT, TRENCH USE 1 TRENCH — 116 (L) X 5' (W) X 3.0'(D) Total depth of system Is 6.0' from original grade. Total depth of gravel below distribution pipe Is 3.0' . PPRROP13SED STs�TEK vtr"t" eoa of N❑TESi NO PRIVATE WELLS EXCEPT S N OF PROPaSED SYSTEM E raTN ETE 1. CONTRACTOR & ENGINEER TO VERIFY INTEGRITY OF SEPTIC TANK AND NO TT= SYSTEMS OF REPLACE AS REQUIRED. INSULATE TANK IF <4' COVER. PRDPDSED WELL EXCEPT AS (E1TEA 2• INSULATE TRENCHES WITH 2' HD BURIAL FOAM. 3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK. 4. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE MIN. 3' COVER IF REQUIRED. 5. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS, SEPTICS, LOT LINES, FOUNDATIONS AND ALL OTHER SETBACKS. I PREPARED FOR, TROY DAVIS HOMES, INC / �,• `� 1451 E. PARKS HWY, SUITE 207 WASILLA, AK 99687 Scale 1'= 100' , PAGE 1 OF 2 ,... _ ...� ... , . _/ FlELD BOOKS COMPUTED: 1 ZM ENGINEERING CE -7118 OWNDARr. LANG DRAMN: STAWNLT NA CHEDXED: KMD 20441 PTARMIGAN BLVD. '' ASBUILT. NA DATE: 5/13/03— 13 03 EAGLE RIVER, AK 99577-8736 SSIO��' : Dwa FlLECMD NW1560 ACAD �` 03028.DWG 'ADD M' 03028 (907)696-6111/FAX (907)896-8111 �o WASTEWATER DISPOSAL SYSTEM DETAILS GLEN VIEW NORTH SID, BLOCK 3, LOT 1 54; PROPOSED ZABE 2000 SPLITTE \ PROPOSED 125 \ GAL TANK m lillip � - T V 1 PROPOSED ' - BDRM HOUSE' PREPARED FORS TROY DAVIS HOMES, INC 1451 E. PARKS HWY, SUITE 207 WASILLA, AK 99687 FlELD BOOKS coNvuim: BOUNDARY.' LANG DRAW STMNc NA scam. Asomr. NA DATE: DNC. ME: CRD: "D"D "`E 03028.DWGl ''DD Nw 03028 Scales 1'= 30' PAGE 2 OF 2 ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 6-611 111 ,firI �F •A� K D ENGINEERING, INC. �;* j r '•,f9�0o 20441 PTARMIGAN BLVD. N EAGLE RIVER, AK 99577-8736 4 ..L �• •���� �• • 0 rn Kenneth h1. D i t+ �e 6.' :� CE SOILS PERCOLATION TEST �f9'''•........••''•��-� ���PROFESSIONP� �` Performed for: _ Troy Davis Homes, Inc. Date Performed: 4/30/03 Project: Glenn View Estates North, Block 3, Lot 1 TEST HOLE # 03-1 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- Depth (Feet) Org/OL-ML —brown silty loam w/organics SM— med dense silty sand w/gp pockets & cobbles 8" B.O.H. HOLE PRESOAKED PRIOR TO TEST SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Groundwater encountered? NO What depth? NA Depth to water after monitoring? 12.8' Date? 5/7/03 Reading Date Gross Time Net Time Depth to Water Net Drop 1 5/7/03 1:00 - 6" - 2 1:30 30 min 2 9/16" 3 7/16" 3 1:31 - 6" - 4 2:01 30 min 211/16" 35/16" 5 " 2:02 - 6" - 6 2:32 30 min 210/16" 36/16" * Water Added Percolation Rate 8.88 (min/ in) Perc Hole Diameter 6„ Test Run Between 4 feet and 5 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. hpr 22 03 09s02a_ Tr, ---41 Davis Homes 907--157 9395 p.7 Municipality of Anchorage J GINEER•S S7CAL'• Development Services Department �.; 8vilding, Safety Division '•, O ".c On -Site Water and Wastewater Program Ar 4700 South Braga;v SL P.O. Box 196650 Anchorage. AK 99519.6650:.• . �., . www.ci.anchoraoee., : _ (907)343.7904v. :Sons t_O g Percolation Test•• '•''?erfrmee Fcr: lam-+ L EN V 1 E 1),'l N 0121 1a :Oatc Performed:• Leal Oesc:ipt:on: L�"T ` 7j iLt4 Township. Range. Section: Depth o26 J ANlc p i . 6 l . l S - f4- u,.. t4 p 4. » 5- 6. 6. (II ejrer_t/RA II 8- H 10- 11- 12- 13- 14 4 15• R ••Eio w, e,-�- -_ Nolte 17• 18• 10. 20- COt. VE NTS &:In a ,_ WAS GROUNO WATER Date ENCOUNTERED7 tai p LL 5 IF YES. AT WHAT DEPTH? L Dtpo110Water After �., D Monitoring) 12JZ? E Oak: 1!2 p2_ Reading Date Gross Time Net Time Depth to Water Net Droa LL RE o K --- 1 :2D 30, Int d _ I•so 3C 9° a:20 �n Q 7�r,� l o i PERCOLATION RATE 3�Iminwes& n) PERC HOLE 01"ISTER � 1 TEST RUN UM'EEN FT AND 4 FT PERFORmEO BY: --- �, S. I PER"CRWED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIOELINS IN FFECT ON THIS CERTIFY THAT THIS TES- L E E. DATE: t 2j° Z ,Ab CI o\\ 1 I ///X/, .I I n1 ,I \`\_ `� 1IIIIIIII 11 -- II I co l a- _ \`\1\I\ l I I II 11111111 1 1 1 11 rlllllll I r CI o\\ 1 I ///X/, .I I n1 ,I mn 1 I �lall.l y�1 rlrl _;f_ I �'�N =m • I 111111 ��' 11111111��1 1 IIIIII IWa� 1 Illl44 fl I�al, 4 ry b 01 l IOW r�Nll1 ���::: �, �� ► c �� \`\_ `� 1IIIIIIII 11 -- II I 1 \ �_ �♦ .1 '11 1�1\1111 l a- _ \`\1\I\ l I I II 11111111 1 1 1 11 rlllllll I r —,� \ \\ 1 II lirrrlll I 11 ' \ \ \11111rr11111 1 r \ \ I\ ►1111\111111 I ' \� `\111111111 \\\\\\\`l\ \\\ mn 1 I �lall.l y�1 rlrl _;f_ I �'�N =m • I 111111 ��' 11111111��1 1 IIIIII IWa� 1 Illl44 fl I�al, 4 ry b 01 l IOW r�Nll1 ���::: �, �� ► c �� Gtf- J»c�A Municipality of Anchorage • Development Services Department Building Safety Division ,i On -Site Water and Wastewater Program ; r; 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. SSI -Sl f 1- 5S COSA # C)goLl UD Expiration Date: /a -- 7— 09, 1. GENERAL INFORMATION Complete legal description °CrLCNrJ VieiA1 FST TPS A)PKTI4 V I (3'3 Location (site address) '9lr—C-4+ Current Property owner(s) ,(AMPS 7onnlnlA 5�pewSDay phone' -3o — ging { Mailing address Lending agency Mailing address Real Estate Agent Mailing Address (�.o• f5o',c 15017-5 . (3lLL4r'1C7S MT Se1(0S e Unless otherwise requested, COSA will be held by DSD for pickup. Day phone Dayphone 699 -(c4 -(n4 - 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site [� Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System a,, Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage Is not responsible for errors or omissions In the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm F_A(:XL-t= p_t V��- Phone Vl q - St `( S Address I % JfW ��. #-.101 FN , A14- C�AS'1l Engineer's Printed Name Date__,gJ!R!T!9*,e200-- 0 I CHRISTOPHER R WOOD 5. DSD SIGNATURE CELLA v '5 F _j/ Approved for _ bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By: �G/%/fi, Lt/ Original Certificate Dale:/ -7—!2-7 (Rw IMS) Municipality of Anchorage Development Services Department Building Safety Division ' On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: CTLErJIJ VIEW rJO)e--r4 Parcel ID: 0ff'/—S/l-5,5� L UT I f3c cc K 3 A. WELL DATA Well type _ If A, B. or C provide PWSID # _ Well Log (YIN) Date completed Total depth ft. Date of test Static water level Well production WATER SAMPLE Coliform L ug/L Sanitary seal (YIN) _ Wires properly protected Cased to ft. Casing height ve ground) in. FROM WELL LOG AT ECTION V3 g.p.m. mL Nitrate mg/L date of sample: _ B. SEPTICIHOLDING TANK DATA ft. Other bacteria colonies/100 mL Collected by: Tank Type/MaterialSEt�f1C t=�=1- Date installed_ Tank size �, 5 gal. Number of Compartments _L Cleanouts (59N) Foundation cleanout ON) _&,75 Depression over tank (Y&N &(C High water alarm (YQ nl 0 Date of pumping Pumper be I S C. ABSORPTION FIELD DATA Date installed 91,1S.10 Soil rating g.p.d./ft' or ft'/bdrm) 0•6 System type Ske I I oig 7iz ✓uq Length 11 1� ft. Width 6 ft. Gravel below pipe 3 ft. Total depth 5� ft. Eff. absorption arealQ-qft' Monitoring tube lt�cS Depression over field -pjn_ Dale of adequacy test Results as Fail) -R� For -tf bedrooms Fluid depth in absorption field before test j `}-5 in. Water added 00 gal. New depth aL in. Elapsed Time:)) min. Final fluid depth 14-S In. Absorption rate >= (0 00 g.p.d. Any rejuvenation treatment (past 12 mo.) (YA" type) OWe P t,1Dt 1Jn I If yes, give date,_ D. LIFT STATION Date installed 'Pump on" level at _ in. Datum Size in gallons Manhole/Access (Y/N) 'Pump off level at _ in. High water alarm level at Cycles tested Meets alarm & E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot V\v V Public sewer main ;ko Sewer /septic_9rO-ce line On adjacent lots On adjacent lots Public sewer manhole/cleanout Holding tank areas Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 4- S 1 Property line +5 1 Absorption field + 5 Water main -4-10, Water service line +10 Surface water 4-10 0 ' Wells on adjacent lots +100 SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line +10 1 Building foundation +10' Water main +1 C) r Water Service line t 10' Surface water + 1 n0 3 Driveway, parking/vehicle storage 0 i Curtain drain +SOI Wells on adjacent lots -1 ,Z F. COMMENTS G. ENGINEER'S CERTIFICATION c�' 49TH 1 certify that 1 have determined through field inspections and ``' review of Municipal records that the above systems are in r _ conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name C hrj n1r) r I klo()rl Date IZ &J t ..;.. COSA Fee $ L/ ??o Date of Payment INO 4 Receipt Number lv 6 3 (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number in. Municipality of Anchorage Development Services Department Building Safety Division ; • t�: On -Site Water and Wastewater Program ' 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 051-81111-55 HAA # L22 0 7 Expiration Date: e2-* 1. GENERAL INFORMATION Location (site address or directions) Whispering Aireh Circle; Chuaiak AK 99567 Current Propertyowner(s) Troy Davie Homes Inc- Dayphone 357-9394 Mailing address Lending agency Mailing address Real Estate Agent Mailing Address 1451 E. Parks Hwy., Ste, 207, Wasilla. AK 99687 Day phone .. .,. .•. Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site Individual Water Storage ❑ Individual Holding tank Community Class Well ❑ Community On-site Public Water System ® Public Sewer The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm KND FNr,[NFFRINr,, Inc- Phone (907) 696-61111 �•• 1 u •.� • .• ; _. •• Engineer's Printed Name Kenneth M. Duffus Date 111261200-4 Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, KND can not give any estimate of how long a system will function satisfactory for current or future occupants or can KND guarantee that no unseen encroachments, deficiencies or discrepancies exist. —LZ Approved for Y bedrooms. g OF 1A4�h istai&r11- 1 1 *?.itaT►i � :_it Kenneth M J CE 71,6 J r� ?80FE Attachments: HAA Checklist X Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other By: _ Original Certificate Dater c Municipality of Anchorage Development Services Department os -6- Building Safety DivisionOn-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal .: .. VIEW ESTATESNORTH.r A. WELL DATA Well type Pubilc Date completed_ Total depth ft. Date of test Static water level Well production If A, B, or C provide PWSID # Sanitary seal (Y/N1— Cased to ft. FROM WELL LOG WATER SAMPLE RESULTS: Coliform _---colonies/100 ml. Arsenic: mg.h. B. SEPTICIFIOLDING TANK DATA ft. 9 -p.m Nitrate _Ing./I. Date of sample: _ Well Log (YIN) Wires property protected (Y/N) Casing height (above ground) AT INSPECTION ft. g.p.m. Other bacteria _ colonies/100 ml. Collected by: Tank Type/MateriDate installed 9/252003 Tank size 1250 gal. Number of Compartments-?.-Cleanouts (YIN) Y Foundation cleanout (YM) Y_pepression over tank (Y/N),_High water alarm (Y/N) N Date of pumping NA - NEW TANK Pumper C. ABSORPTION FIELD DATA Date installed 4/25/2003 Soil rating (g.p.d./fe or felbdrm)�M System type .trench Length -18 ft. Width S ft.Gravel below pipe 3.17 ft. Total depth §_ ft. Efl. absorption area 1017 fe Monitoring tube Y Depression over field N Date of adequacy test NA -NEW SYSTEM Results (Pass/Fail) Pass For _4-- bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in, Elapsed Time _min. Final fluid depth_ in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date ----- D. LIFT STATION Date installed NA Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off" level at in. High water alarm level at in. Datum Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main On adjacent lots On adjacent lots Public sewer manhole/cleanout Sewer /septic service line Holding tank SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 10 0'+ Wells on adjacent lots 200'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 1 0'+ Water main 1 0'+ Water Service line 10'+ Surface water 10 0'+ Driveway, parking/vehicle storage 1 0' + Curtain drain 50'+ Wells on adjacent lots 200'+ F. COMMENTS cE of Al i • ��� Aw C2 G. ENGINEER'S CERTIFICATION field inspections and * •4 ••L •IR 0 ••••• • '+O/0 I certify that I have determined throughp review of Municipal records that the above systems are in ••N• conformance with MOA HAA guidelines in effect on this date. C�E 71 ZP NZ 00 Engineer's Printed Name Kenneth M. Duffus 1+1F9 ••• }'•••�C��"� t`cO/'ROFESSt0�Pe'� Date Al /26/2003 HAA Fee $375.00 Waiver Fee $ _ Date of Payment 11/26/2003 Date of Payment Receipt Number Receipt Number (Rev. 12/01) 010 as Two STORM WOW FRAME REEDEWE 19—K -1i HOUSE DETAIL Lot 15 SCALE 1 • - W 15' TELECOM. a ELECT. EASEMENT Lor 1 SEPTIC 0001 L-31A2� \ o V Q � R•20.00 �� Lot 2 PLOT PLAN _ ASBUILT Y- SCALE 10 ' So• GRID ! 15eo Project No. Lan & Associates, ince 11500 Daryl Avenue, Anchorage, Alaska 99515 9 907 522-6476 Phone Registered Land Surveyors (907) 522-4625 Fax OF A( I hereby ovilty that I have .urwy.d the roibwinp dnormed property �`C •. . • • qs Lot 1. Block 3. GLENN VIEWESTATES NORTN W. (Plat No. 2003-9) l.>rt Anolwro9. Record) oa+a . WU�ia1id *? 49MJ Meson are wllhin R+e property Bnuand donut enoroaaoMo 1Mtpraperlyo •••: odlooent thereto. that no Imprvwmenh on 1M properh MnY 1 1 . enor000h on 11re surveyed prombn and Mat there are no r� trommisdon/v.. �... . Bnes or other vbibh eaeemade on eakl properly exoepf o. Mrecn• KENNETH 8. L 0 t +I^ 1.2511 CAM jn2 _ at Mohorape. Alaska LS -5202 . Doled Mb 1M 1LO Day of '••.__ _. N M the respemR+�the owner to determine Me exk%nos Of easements. , or whlah do not appear on the Hoarded subdhbkm Pk+t.