Loading...
HomeMy WebLinkAboutSUN VALLEY NORTH BLK 4 LT 9Sun Valley North Block 4 Lot 9 #050-652-12 ,,,r _; :_ ,;__,- ^_ ~. _lwumc,lJanty,u,~_mcnorage Page 1 of 3 Development S~ices Depa~ment On-Site Water and Waste~ter Pr~mm 4700 Sou~ Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 ~.ci.anchomge'.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW030072 PID Number: 050-652.12 Na~: Hailer Construction Wastewater System: New Address: P.O. Box 110731 Anch., AK 99511 ABSORPTION FIELD.' Phone: N~er of Bedrid: 245.3010 Four {4) Deep Trench LEGAL DESCRIPTION ~, ~,~: ,?~ ~ o,~,~ ~: ~k: Lot: SubdM~on: Dep~ to pl~ ~ttom from odginal grade: Grovel depth ben.th ~pe: 4 9 Sun Valley Nodh 2 ,,. 10 T~shlp: ~nge: S~ion: F~II added ab~ ~nel ~de: Grovel Leng~: 1-3 rt. 85 WEll: New Gm~l ~dth: Nu~er ol lines: ~ Die.rice between lines: 3 ~. 1 ' ~t. I Classifi~tion (Pd~te. ~ B, C): To~l Depth: Cased Io: To~l ab~ area: P~pe ~terial: Private i53 152 1,700 Fe ASTU3034 PVC Ddlle~ ~te Dffiled: StaSc Wa~er Level; ~s~tler: Cate Installed: Hefty Drilling 5~8~2003 126 ~L BTH Construction 5/13-t4/2003 ~eld: 4 GPM ~J Pu~ Set at:R.lJ Casing ~ eight~2~O~FLG~nd: TANK SEPA~TION DISTANCES ~ Septic D Holding D S.T.E.P. D Othe~ T~ To Septic Absorption Lift Holding =ubli~Hvate ~nu~acturer; ~pa~[y m ~allons; F~o~ Tank Field S~fion Tank Sewer Line Anchorage Tank 1,250 Material: Nu~er of Coca--nfs: >~00' >100' N/A N/A >25' Steel Two (2) W~I ~=.w=,,~>100' >100' N/A N/A ~ ~ LIFT STATION- NONE ON LOT ~o,u.= >5' >10' N/A N/A~ =,=e. GaL ~.~t,o. >5' >10' N/A N/A -~u~o.-,~v~,.~: -~po,~,~.,~,: In, In.I In. Cumin Drain None Noted m~ ~. ~.~, ~,~:.., ,..~o.. ~..o~ "~"~': BENCH MARK LO~t~O~ 8~ ~es~tptio~; Garage Slab. Assu~d Elemtion: 100.0 Engineer's Stamp Inspections performed by:A. Harala Dates: 1't 511312003 * 49 h · 2~ 511412003 ~ MICHAEL [. ANDERSON Depadment of Health and Human Se~ices approval ~ ~;,, Uo. c~-~, Reviewed and approved b Date: /2 '~ ~- 0 ~ Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - On-Site Wastewater Disposal System or Well Inspection Report Permit Number: SW030072 Page 2 of 3 PID No. 050-652-' ELXHORN C k,fl $1 $2 S2 C4 Ul C5 M2 16.8 7.0 23.6 12.5 4~).o I so.9 46.1 156.4 81.8 167.1 7.3.5 J59.6 PLAN AS-BUILT SCALE ~,° = 50' MICHAEL £. ANDERSrlN No, CE-4381 LOT 9, BLOCK 4, ~SUN VALLEY NORTH SUBDIVISION Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Ancl'iorage. AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: SW030072 Page 3 of 3 PID No. 050-652-12 F101.3 II ~ /~ ~' . · I Il,E50 Gotton~ · /IS.p*~: T~..I~ 95.~ I I 95.35 94,$ 84.7 ' 99,8 ......... Ge__o~,ex__.~!le_ F.__o.lo r-l.._.~ .......... ]:)rcdnFletd Rock 85' 84,55 / 78.2 94.9 PROFILE AS-BUILT Scale: 1" = 10' Municipality of Anchorage 4700 South Br-agaw Street Anchorage, AK 99519-6650 Development Services Depadment SOILS LOG - PERCOLATION TEST t t ¢ -- '1 3 4 1 1o 12 14 17- i' oo SITE *P L~". H WAS G~OUND 'WATER' ; ENCOUNTERED? IF Y~. AT WHAT O DEP~? p Grot Net · ' ' ] DePth to' Net ~-' . PERCOLATION RATE __ (minute~/inch) Pc. AC HOLE DIAMETER TE~-r RON SET~'vE. EJ~ ~ FT AND F'T I ~TJFY T~T ~HtS ~CCORDA~ICE WiTH AL.L STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE_: TEST WAS PERFORMED IN zz-z~f ICERFORMED FOR: FROM FAX NO. :245-3010 Dec. 02 2003 12:21PM P2 :HALLER CO HEFTY 'DRILLING 3540 AKULA DRIVE ANCHORAGE, ALASKA 99516 (907) 345-0593 STATE OF ALASKA . ~.:. ·. DEPARTMENT OF NA:FURAL RESOtIRCES "MINING, LAND, WATER HYDROLOGIC SURVEY WATER WELL LOG Drilling Started:._~.~/., a~ O/.=~_, Completed: ~. / ~ / 0.~_ Meridian ................. Township ...... Range Section ... ~ of .... ~ of . Late N . . ' ...... Long: W ......_NAD: 2.7 OR 83 Elevation: BOREHOLE DATA: (from ground surface) Depth Drilling method: ~-..Air rotary, ~ Cable t.~l, Other Mater/al: Type. Cxalor & wetness [ F_rgm. ] To Well use: D Public supply, g, Domestic, D Other · 7tx Depth of hole: I ~ fl, Casing stickup: ~ R '-' ~- ~,~/ Casing diameter: L inches Casing depth · ~ ~ Staficwat:r(froh~opofcaslng): /~' fton ,~/ OC".' Recovery rate: e./. gpng Method of testing: x.g... -- Well intake opening tTp¢: 3~:)Pen end. D Open hole ~ Screen type: Slot/mesh size :'__~J~.t~d q ~,'a ,I 1/-'J ]4Ad 1~O i/ ~.]_ ~ Perforated;Start: fl, Stopped Stag: fl, Stopped Note: Depth; from fl, to ft Pump intake depth: __ Pump size bp, Brand ~n~: . Was well disinfected upon eqmpl~ion? ,~3Yes, ~ No Method Driller comment.s/d/sclaimers: .............. ' ................... Company Name:_. HEF~I-Y Mailing Address:. 3'540 A'KULA DRIVE city:. ANCHORA~_~._State: ALASI~ ~Zip:. 99516 i Phone Number :. _'1 ,-907-345-0,5~:~ - ~ ~ Drillers Slgnatura: ~ .Oa.O~0. ~. 1~.020 ~ AK ~ulaflot~ l I ~C 95.140). DEPARTMENT OF NATU~L RESOURCES Mi.I.g, ~nd& .Water Hydro,lc 550 W 7th Ave. S~t¢ ~A Ancbo~AK W~lepbone (~) Z69~639 and FAX (~7) Within thc City of Anchorage, it is required Lhat a copy of the Well log sent to fl:e approp~at, city offlcc w/dlht 60 days and that another cop>, of the well log be sca to the well/properly owner w/t~[n 30 days. Permit Number: · Date of Issue: , / '" Parcel Identification Number . Is wen localed at approved perrait Ideation? ,'2 Yea or G No MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Date Issued: Apr 10, 2003 Expiration Date: Apr 09, 2004 Permit Number: SW030072 Legal Description': ~.Sbh~/~lle¥ N0-rth'BlOck ~'4~Lot 9?' Design Engineer: 0014 Anderson Engineering Owner Name: Hailer Construction Owner Address: PO Box 110731 Anchorage, A 99511- Parcel ID: 050-652-12 Site Address: 22339 Elkhorn Cir Lot Size: 82059 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank [-'] Holding Tank [~ Privy ~'] Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. Permit Number SW 0'~00 Property~owner(s) Hailer Construction Mailing address (1) P.O. Box 110731 Anchoraqe, AK 995,11 Day phone 245.3011) Mailing address (2) Legal description (Lot, Block & Sub'd.) Zip Code Lot 9~ Block 4, ,S,aa~,at~ North Subdivision Legal description (Section, Township & Range) Lot Size ~:~SF Acre~s~ THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool Number of Bedrooms Four (4) r--] Well Only [] I~ Water Storage [] I-"1 Jacuzzi [] '['-I Water Softening Unit ' [] I certify that the above information is correct. I fudher' cedify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Receipt Number: (Rev, 12/00) Waiver Fees: Date of Payment: Receipt Number: April 7, 2003 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 9, Block 4, Sunvally North Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 9, Block 4, Sunvally North Subdivision intends to construct a four- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to serve the home. The attached Site Plan and backup documentation identify the location and configuration of the well and the new septic system and alternate site and the parameters used in the design. Also identified on the plans are the test hole locations and well and septic systems on the surrounding lots. Drainage arrows and contours are shown indicating the current drainage patterns. The drainage patterns will be maintained after construction. The test holes placed near the location of the proposed absorption trench indicated silty gravel with varying amounts of sand and a percolation rate of 57 minutes per inch. No ground water was found during placement of the test holes and none was noted dudng the monitoring period. We are therefore proposing to place a 1,250 gallon'septic tank and a new 80' long by 3' wide by 10' effective depth absorption trench. The trench will be oversized due to the slow percolation rate of the accepting strata. The total depth of the trench will be 12' below the surface with the distribution pipe at 2' below the surface. Sufficient fill will be placed to prevent freezing of either the septic tank or the absorption trench. The ground surface on the lot slopes as shown on the site plan from north to south at varying slopes. The absorption trench will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. All components of the new septic system will be constructed a minimum of 100' from any surface water and wells in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells Lbt 9, Block 4, Sunvally North April 7, 2003 Page Two in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. .. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments Unedeveloped 1_0 11 6 8 AR EA MAP '"'"'""""""'"': No. C[-438! AlternotE Gollon 80' Long X 3' W~de X 10' Effective Depth Absorption Trench SCALE 1" == 50' LOT 6, BLOCK 4, SUNVALLY SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Deep Trench System Perc. Rate: 47-57 Min./Inch 1,250 Gallon Septic Tank · Avg. Application Rate: .45 GPD/SF 10' Drain Field Rock 4 Bedrooms X 150 GPD 1.45 GPD/SF = 11333.3 SF of Absorption Area 1,333.3 SFI20 SFILF = 66.7 LF Trench Length Therefore: Construct an Absorption Trench to Oversized Dimensions 80' in Length by 3' Wide with 10' of Drainfield Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 2' Below Existing .Ground. Total DePth of Each Trench to Be 12' Below Existing Surface. Cover Over Septic Tank a Minimum of 4' or 2" of Insulation and 2' of Cover. Cover Over Trench 3'. 6~ 10'0" I Natural. Backfill ! Geotextile Fabric 4" Perforate~ PVC/ Schedule 40 DrainfielG Rock / 3~ NOTE: TYPICAL DEEP TRENCH SECTION (NO SCALE) Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 10' From Lot Line.' Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 10' Separation From Water Service Line. Municipality of Anchorage Development Services Department 4700 South Bragaw Street Anchorage. AK 99519-6650 SOILS LOG - PERCOLATION TEST PERFORMED FOR: '=,' ~.~-" ' A _~"-..'~7 *. - · .Cn% NO CE-438~ :~ DATE PERFORMED: Township. Range. Section: 5 6 "~o'- 11- '12- IF YES. ATWHAT · ' : L O · DEPTH? p E .~,~;,~? None 0~ 4/1 '/03 13- .14 - 15 2O r'E.COUmO. TEST RUN 8ETWEE~ ~'~ . __ {rn;nu~c~/inch) PERC .HOLE DtAMETER . nANO ~'"~ rT II ..................... t ...... ,- -~,,u ..u~,ulr~L {~umoc. Llmr..S iN E;'F~.C.T ON THiS DA~F_ DATE: CERTIFY THAT THIS TEST WAS PERFORMED IN Municipality of Anch~)rage ~. · Development Se~,ices Depadment _ . ,,:~:....~....~2~ 4700 S~uth Bmgaw Strut ~age, AK ~519-6650 SOILS LOG- PERCO~ON ~ST LEGAL DESCRIPTION: ~ T '~, ~1< ~ Tow~hip. Range, Secfion~ x, 20 ' 14 15 PERCOLATION RATE '~'''] CminutcS/inch} PF-.RC .HOLE DIAMETER __ - - TEST RUN BE'T'VV~ '1' (~' ' F'T AND ~* ~:" FT '2 6 7 13 14 15 i6 17 18 19 20 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH/),ND ENVIRONMENTAL PROTECTION "' 826 L. ~,t~e~t..~*mh~raOmo Alatk~ g~01 ~1(344720 [~sol LS I. OO SOl L$ LOG -- PERCOLATION TEST · SLOPE o o SITE PLAN Y N~. ~1,~ ENCOUNT~:RED~' IF Y£8o AT WHAT DEPTHS' PERCOLATION RATE _ . [mlnule~m~h) '' TEST RUN BETWEEN . ~"'/. ~ · FT AND __- ~-/~' O: FT ..~(~ · ~ · Flar~12 2003 8: 29RPI ~)TH Constructi on, LLC AAUNIC:IPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROT£CTION 825 L. Strmmt, Ammh~o~, Alaska ggS01 2B4.4920 SOIL~ LOG -- PERCOLATION TEST PERFOR.MED FOR: ! 2 3 4 '6 6 7 9 10 11 13" 14 15 16 17 18 19 20 ~^SENCOUNTERED,GROUNC ~ATERI~ ~ [ . .o SITE PLAN IF YES, AT Id,TI'AT · .. DEPTH~ Cole Oro~ Net D.pth to Nat PERCOLATION I~TE /~/4 Cmlnule,lln~hl O^TU, / ?2.oo.e [6/7l*) ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND'MATERIAL SPECIFICATIONS SUBJECT: LOT 9, BLOCK 4, SUNVALLY NORTH SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,250-gallon tank at the location shown on the site plan. Work also includes the construction of a new absorption trench 80' long by 3' wide by 10' effective depth also at the location shown on the Site Plan. The total depth of the trench will be 12' beloTM existing ground and the distribution Pipe will be placed at 2' belowithe surface. All components of the new absorption trench and septic tank must be constructed a minimum of 100' from any surface water or wells in the area. A minimum of 4' of cover is required over the septic tank and 3' over the absorption trench. In lieu of cover 2" of direct bury insulation and 2' of cover may be placed. ' Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive pdor approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,250-gallon septic tank must be procured from a certified septic tank manufacturer if the existing tank is found to be defective. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. All standpipes on the septic tank Shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. Lot 9, Block 4, Sunvally North April 7, 2003 Page 2 of 3 A foundation cleanout shall be installed one to four feet.from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below.ground must be perforated. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall vedfy this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). · Lot 9, Block 4, Sunvally North April .7, 2003 Page 3 of 3 5. A.permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. Municipality of Anchorage DeveloPment Services Department ~,\ B[~ilding Safety Division ."J · On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Expiration Date: GENERAL INFORMATION Complete legal description. _.Lot 9, Block 4, Sun Valley North Subdivision Location.(Site address or directions) Elkhom Circle Current Property owner(s) Mailing address Hailer Construction P.O. Box 110731 Anchoraqe, AK 99511 Day phone 245.3010 Lending agency Day phone Mailing address Real Estate Agent Day phone e Mailing Address "unl~S otherwis'e requested, HAA will be held by DSD for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual'Well Individual Water Storage Communi.ty Class Public Water System Well Four (4) TYPE OF WASTEWATER DISPOSAL:' [] Individual On-site [] [] Individual Holding tank [] [] Community On-site [] [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue fbr properties served by a private or Class C well and may be reissued with new v~at~r sarhpl~ results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for propedies served by Class A or B wells or a public Water system. The Mun, icipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 12/2212003 5. DSD SIGNATURE V Approved for _ �' bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments j 'UNS1-1 -0 SE M : WATER AND WASTEWAT PROGRAM • t Attachments: HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other BY: 4eOriginal Certificate Date: 12% — 2 G • 0.3 (Rev. 12/00) ' 't ' . ~ :Develol3ment"' ~" ~ :'"'= ~'Servlces ~ "Department i i::~i ~ ~ i~i , ' '~ ' .; . ~ Bu'd'ngSafetyDiv's'on ,'; ~, ' , , ' " ' ,.~: ~ ,.~ i ~ ~ On-Site Water &:Wastewater Program, ' : ~ ;:' ~ .', '~ .... ' : ' ,. :. ';,',~700'SouthBragawSt ' , ~ . ' . ,,~ :~:' . · , . ,. :;,P.O. Box196650 ~Anchorage, ~K 99519-6650', : "~' ::,;~ ~[' ......... ~ , ,,~ ,~.c.anchoraoe.aE.Us :. ~, ~ ..... ,, .............. 907 343-7904,, , ,, , "~ ~ ' ': , ,'; ~EAUTHAUTHORITY-~PPRDVAL'~M~U~LI~/.: Legal Descripton'. Lot ~9, Block ~ 'Sun Valley No,h Sub~lvlsmn~ '- .... ~ ~ ~ Parcel'lD '~050'65242 WELL DATA ,.., ~ . ~ . ~ Wellt~ePrvate : .... :,~,.: :~,~:lfA, B. orCprowdePWSIDfl~ .... ~, ~,~,.,WellLog~/~)y Dat6 comp et'e~ 5/81~0'03:' .'., ;~ S&nit~ ~bal ~(Y/N) Z J' :~ i: ~ ~ir~ Pr~p'e[ly Protected (~/N) Y .., ......... , , ,,, , ........ ., ,,. ...... .. Totalde-th 153 ff :' : CaSedto ,152 ft ":~ ,'~ ' ~1: [jCasnghelght(aboveground) 24 , n. ,:~ ; .,. ': ,';~,'~FROMWELELOG,'" .... :,':, ~,l,~ ~ATINSPECTION : ',' ]~ ' WATER SAMPLE RESULTS..,,. : ,, : ~. ,~ ,~' ~: , , ~ ,, , ,,,~ C01ifo~m 0 'colonies/100~ ', :~ ~, 'Ntrater'.761 mgT., :: ,, ~"'. {' ~t~er, bac~ena-,0 ?~lomes/100ml. Date of sample: , 1~5/2003 ....... ~ ,Collected by. ,. MEA .... ~ ...... F SEPTIC/HOLDING TANK DATA ~,~ ~, , , ~ ...... I~ ' ' ~ '~ ~" TankTvae/Material, Se~ticlStee~ ~ ~; ~tl; ,,:; '..,:~ ;',;'; = ;:; [ ,~ ',~ ~'t, ~Date installed ~5fl312003 =~ T~nksize :;1250~ gal.::::'.'-,, ~ ;'Nbmber,of~Co~padments[ '[ ' [:'~ i~l~anouts(Y(N)Y .~ Foundation cleanout (Y/N) Y ','~ Depression Over tank'ff/N) N: ~ ~High water alarm (Y/N) N ABSORPTION FIELD DATA ,: '. ,' ~'~,,, ~; ,, :~ , , : , ' ., , : D~te instal 60 =a4)2~ ::' ~, ~so rat,nfl (g.p.d./ft~ or ft2!bdrm):45 GPDISF ;: System type', Deep',Trench Tnf~l ~nlh ~ {t ....... Eft absorot~on areal.700 ft . ' Momtor ng tube Y De ress on over field N ,, 'D~te ofade°Uacvtest' ': i ":~ , ' ',~ 3 Red,Its (Pass/Fa') ,~:,.i '~ ~: :: '.: ,, Fo~,~ bedrooms Fuiddepthinabsorptonfedbeforetest,':{l[.,n].';: ,: Vi: :e:added'~:~ ,'. gal. , New depth_ __ in. 5( i', ,, ,, : ,~ : . : : ~ ~ t : ,.~ : : ; l: ~ :[[ ~ ~ , ,~ , ,, , : , . Elapsed Time' ~ ::. m n: ~,' ~ Fha flud depth , '.: :!~ln.' ~ :~,: Absorption rate ,>= :l: , g.p.d. ' ' ·" ' ..... :" ' ......... ~: :~. If yes ivedate , ._ Anyrejuvenatlontreatment(past12:mo.)( ~:~&~ype)~ .. ~~ ,g - ::~ ;~' ;: ""'~ ;~': "' : l:; l~~ :." i [ ~:, '~,:l; ~.,: ' D. LIFT STATION Date installed "Pump on" level at Datum Size in gallons in. "Pump off' level at in Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL. ON LOT TO: Manhole/Access (Y/N) _ High water alarm level at Meets alarm & circuit requirements? Septic tank/lift station on lot >100' On adjacent lots >100' Absorption field on lot >100' On adjacent lots >100' Public sewer main N/A Public sewer manhole/cleanout NIA Sewer /septic service line >25' Holding tank NIA SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Absorption field >5' Water main NIA Water service line >10' Surface water >100' Wells on adjacent lots >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10' Water main >10' Water Service line >10' Surface water >100' Driveway, parking/vehicle storage >25' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and my49 h review of Municipal records that the above systems are in 0: ...... ......••T �' • •••••• conformance with MOA HAA guidelines in effect on this date. �:`...... _ MICHAEL E. ANDERSON ' i Engineer's Printed Name Michael E. Anderson, P.E. ��rs�: No. CE-4361.v~� Date 1212212003 #iZ14JAfR0FESSI4N��� h1Awwww�� eav HAA Fee $ Waiver Fee $ Date of Payment /'z- zz-o3 Date of Payment Receipt Number 4-57 V Receipt Number (Rev. 12100) 1~--17--03~ 5=4~PM= SGS Refit/ Client Name ProJ ec~ Name/# Client Sample ID Matrix 1037927001 Anderson Engineering Sun Valley North S/D L 9 B 4 Sun Valley North S/D L 9 B 4 Drinking Water ;907 5615301 # 2/ All Dates/Times arc Alaska Standard Time Printed Date/Time 12/17/2003 16:28 Collected Date/Time 12/15/2003 12:45 Received Date/Timeff 12/15/2003 14:20 Technica! ~~ ~ Released By"~ v ... - - I Sample Remarks: ' Allowable Prep Analysis Parameter Results PQL Unit~ Method Container ID Limits Date Date Init Waters Department Ni~xate-N 0.761 0.100 mg/L EPA 300.0 B (<ri 0) 12/15/03 JJB Microbiology Laboratory Total Coliform TNTC OB col/lOOmL SMI8 9222B A (<ri) 12/15103 DKC - PRELIMINARY - 11 LOT 7,32~ BLOCK 4 HAS SQ.FT. OF AREA .. T H F~L.O~ .IS ~RD 6 10 FOR: ttALLER CONSTRUCTION'-' 8-14-03 LanMa k : ' Grid 93~0 Vanguard Drive, S~ite ~0~ ~chor~ge, ~aska 99507 :'-.. Drawn by · I hereby certify ~at ~e ~roperty described ~e~eon ha~ .been ~eyed by me: or ~ my direction, end ~ the i~pravemen~ situ~Led ~ereo~ are within ~e propar~y line~ and do not overlap or encroaeh"'~ the propcr~y .tyk~g adjacent ~ercto unless othevwiee shu.x.. That impro~emer,~ on fl~e prope~y lying adjadent thereto encroach premi~e~ in question and ~n~ there are no roadways, ~anxmission '-'. Hnee er ether easemen~ on said property except a~ sho~. '- It i~ the responsibility of ~e owner or bu~der, prior %0 construction, to verify proposed building ~cade relative to finish grade ~nd utility connec~ous and %o determine the existence of ~ny easemen%~, covenant, or res~ietions which do no( appe~ on ~e recorded subdi~sion plat.  .~%~d dJh%anee~ prevail over sealinE. ~ep'roduction may eauee di~l.c,r~on. Scal~ 1" =80' Plot Plan 2300238 ?ield Book Legal Description 9 I Block 4 SUNVALLY NORTH SUBDIVISION