Loading...
HomeMy WebLinkAboutSPENDLOVE VIEW HEIGHTS BLK 3 LT 1Sp ndlov View Heights Block 3 Lot 1 #021-021-09 Municipality of Anchorage • • Development Services Department Building Safety Division On -Site Water Water & Wastewater Program, 4700 South Bragaw St. 5 i Y. 1 Y P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number. SW020351 PID Number. 021-021-09 Name: RON SHINE Wastewater System: ■ New ❑ Upgrade Address: P.O. BOX 220829 * ANCHORAGE, AK 99522 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 227-9201 4 0 Deep Trench ■ Shallow Trench 0 Bed O Mound 0Other•* LEGAL DESCRIPTION Soil Rating: **4.0 Total Depth from original grade: CPD/Sq. Ft *0' TO 1.02 ABOVE FL Block: Lot: Subdivision: 3 1 SPENDLOVE VIEW HEIGHTS Depth to pipe bottom from original grade: SEE DWG. Gravel depth beneath pipe: 0.5 Ft. FL Township: — Range: — Section: — Fal added above original grade: Gravel length: SEE DWG. FL 40 FL WELL ■ New ❑ Upgrade Grovel width: 5 Number of�flnesr.Dlstcnce between fines: Ft, 1— FL Classification Private. A.B.C): Total Depth; Cased To: Total absorption area: Pipe material: PRIVATE 208 FL 54 FL 200 so. FL D 3034/ F-810/SCH 40 PVC Eisler. ALPINE DRILLING Date Drilled: 111/15-16/02 Static Water Level: 0 Installer. A+ HOME SERVICES Date install 2 25-28/2003 FL Yield: Pump Set At Casing Height Above Ground: 3 CPM UNKNOWN FL 2 FL TANK SEPARATION DISTANCES 0 Septic 0 Holding ■ S.T.E.P. ■ Other** To Septic Absorption Lift Holding Public/Privote Manufacturer. Capacity In gallons: From Tank rield Station Tank Sewer Unes ORENCO SYSTEMS/ANCHORAGE TANK 1500 Well 100'+ 100'+ 100'+ - 25'+ Material. FIBERGLASS Number of compartments: 2 surface Water 100'+ 100'+ 100'+ - - LIFT STATION Lot Line 5'+ 10'+ 5'+ _ _ Size in gallons. Manufacturer. 1500/81 ANCHORAGE TANK ORENCO SYSTEMS Foundation 5 + 10 + 5 + - - 'Pump on' level of Pump off level at Ngh water alarm at: TIMER/1" TIMER 18.5" 46"/44" Curtain Drain NqNE KNOWNPump Male & Model: 0octrical Inspections performed by; ORENCO Remarks: *TO TOP OF SAND FILTER. BENCH MARK "THIS IS AN ADVANTEX TREATMENT SYSTEM. Location and Description: BOTTOM OF SIDING ON SOUTHEAST CORNER Assumed Elevation: 100.00 Ft, ENGINEER S S L ooQoo 04 o� Inspections performed by: AKWWC, INC. Dates: 1st 2/25/2003 �:. 0 H 2nd 2/25/2003 „ 3rd 2/28/2003 QO e A. nese. Development Servicesp par ent proval dog C —7953 4- •' ticp�v .. Reviewed and approved by: Date: 22 .04P 4'sf (Rev. 12/01) -oress10oo� DOOoo PERMIT NUMBER: AS -BUILT DRAWING PARCEL ID NUMBER: SW020351 021-021-09 NEW WELL ` SPENDLOVE DRIVE 1 10' UTILfiY EASEMENT I NEW 4 BEDROOM _eJ3 HOUSE II NEW 1500 GALLON ADVANTEX TREATMENT I UNIT w/ PUMP VAULT - II / ALTERNATE SITE UB L'_ S- J NEW DRAINFlELD H14 V NOTE: THE TEST HOLE LOCATIONS ON THE DESIGN WERE NOT CORRECT. THE ACTUAL LOCATIONS ARE CORRECTLY SHOWN ON THIS AS BUILT. 4THB2 II II °ti TTH11 I I 1p°-�o II II II NOTE: THE 100 FOOT WELL I I RADIUS WAS MEASURED WITH I I A TOPCON TOTAL STATION. A I R ST1 58.31 40.12 POD 62.11 39.63 MH1 a 39.70 MH2 ISI � MT1 47.90 30.24 MT2 81.28 36.14 10' UTILfiY EASEMENT I NEW 4 BEDROOM _eJ3 HOUSE II NEW 1500 GALLON ADVANTEX TREATMENT I UNIT w/ PUMP VAULT - II / ALTERNATE SITE UB L'_ S- J NEW DRAINFlELD H14 V NOTE: THE TEST HOLE LOCATIONS ON THE DESIGN WERE NOT CORRECT. THE ACTUAL LOCATIONS ARE CORRECTLY SHOWN ON THIS AS BUILT. 4THB2 II II °ti TTH11 I I 1p°-�o II II II NOTE: THE 100 FOOT WELL I I RADIUS WAS MEASURED WITH I I A TOPCON TOTAL STATION. A I R ST1 58.31 40.12 POD 62.11 39.63 MH1 66.36 39.70 MH2 71.87 40.07 MT1 47.90 30.24 MT2 81.28 36.14 o� " 11/20/2003 0�4 � t� ... DRAWN BY: ALASKA NVATER & ANASTEINTATER C.I.G. CONSULTANTS, INC. scaLE: 1" - 40' �......... ................. 3701 E. TUDOR ROAD. SUITE 101 • ANCHORAGE. AK 99507 • PHONE (907)537-6179 • FAX (907)338-32L6 - PREPARED FOR: PHONE NUMBER: PAGE NUMBER: RON SHINE (907) 227-9201 2 OF 3 r am ss* LEGAL DESCRIPTION: SPENDLOVE VIEW HEIGHTS SUBDIVISION; LOT 1, BLOCK 3, Qoo4,� C 79 • a`vo TYPE OF WORK:D 4ed ....... �o AS -BUILT DRAWING OF NEW WELL AND SEPTIC SYSTEM 0 DOp�ofes Q" PERMIT "UMBER: AS—BUILT DRAWING PARCEL ID NUMBER: SW020351021-021-09 TOP OF ADVANTD( POD TOP OF MANHOLE _ = 96.03 (AVG.) 96.04 (AVG.) FINAL GRADE TOP OF MANHOLE 95.99 (AVG) 96.32 (AVG.) FLOATS INSULATION ................... ..... .. _ TOP OF TANK = 91.90 I TOP OF TANK = 92.00 INLET 4�--_..___...._.._... INVERT OF IN WERT OF = 92.15 OUTLET _ 93.01 INVERT PIPE • •1500 GALLO• = 911.. 32 ADVANTD(; i TANK BOTTOM OF PUMP VAULT - 88.36 ORENCO PUMP VAULT PLYWOOD AND VISQUEEN BARRIER ml FINAL CRADE _ 98.535 (AVG) PLYWOOD AND VISQEEN BARRIER FILTER FABRIC ORIGINAL GRADE _ INSULATION 94.65 (LOWEST POINT) 95.69 (HIGHEST POINT) TOP OF SAND - 95.67 (AVG. BOTTOM OF DRAINFIELD = 91.72-93.67 (SEE NOTE) OF M.Ok. APPROVEDY'i AND, F]4TER 5'---+ NVERT OF PIPE - 96.17 (AVG.) THE DISTRIBUTION PIPE IS 1.25 INCH PVC W/ i INCH HOLES SPACED EVERY 15 INCHES ON CENTER (30 HOLES TOTAL) RELATIVE ELEVATION OF BOTTOM OF TESTHOLE = 86.69 —( DATE: 11/20/2003 �.___._�! ?�..__ __�• t DRAWN BY. ALASKA ANIATER &; WASTE `AIATER C.J.G. CONSULTANTS, INC.SCALE: 3701 E. TUDOR ROAD. SUITE 101 • ANCHORAGE. AK 99507 • PHONE (907)337-6179 • FAX (907)338-324.6 N.T.S. PREPARED FOR: PHONE NUMBER: PAGE NUMBER: RON SHINE (907) 227-9201 3 OF 3 LEGAL DESCRIPTION: SPENDLOVE VIEW HEIGHTS SUBDIVISION; LOT 1, BLOCK 3, TYPE OF WORK: PROFILE AS -BUILT DRAWING OF NEW SEPTIC SYSTEM �V1�0o1 J r y Ga ness.. Q 9. E-79 3 _ .. • ,moa V f 4e ... ap�ofessio�°oo �DO0000�� FROM : ALPINE DRILLING FAX NO. : 907 345 0202 Mar. 17 2003 11:32PM P1 ® Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Sox 196650 Anchorage, Alaska 99519-6650 Rick Mystrom http:/hwww.d.anchorage.akus Mayor Permit Number.. #SW 020351 Date of Issue: 9-17-2002 Parcel Identification Number: 021-021-09 Date Started: 11-15-02 Date Completed: 11-16-02 Is well located at approved permit location? ® Yes ❑ No Legal Description: Spendlove View Hghts Blk 3 Lt 1 Property Owner Name & Address: Ron Shine PO Box 220829 Anchorage. Alaska 99522 Borehole Data: Soil Type, Thickness & Water Strata Depth (ft) From To Method of Drilling ®air rotary ❑cable tool Casing type: steel stick-up 0 2 Wall Thickness: .250 inches organics & silt 2 4 Diameter: 6 inches Depth: 54 feet gravity silt 4 21 Liner Type: Silt gravelly silt bedrock 21 28 51 28 51 208 Diameter: inches Depth: feet Casing stickup above ground: 2 feet Static water level (from ground level): 0 feet Pumping level: 208 feet after 2 hours pumping 3 gpm Recovery Rate: 3 gpm Method of Testing: airlift Well Intake Opening Type: ❑ Open End ® Open Hole ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet Grout Type: Bentonite M Volume: Lbg Depth: Start 0 feet Stopped ? feet Pump: Intake Depth feet produces 100 gpm Pump size hp Brand Name Well Disinfected Upon Completion? ® Yes ❑ No Method of Disinfection: chlorine tablets Comments: Well Driller: Alpine Drilling & Enterprises PO Box 110496 Anchorage Alaska 99511 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property . . . . ...1......71 .7.'11....7..11 »�....�. .....711.. a. a7.. 7'�.»• .tTT..la1. O •7..».... f�.�.... ..�aL!.. /A 1. .i ■■�EC-12-2003 12:33P FROM:A+ HOME SERVICES, IN 907-868-6770 TO:3383246 P:1/1 00 rr r December 12, 2003 ED'S ELECTRIC INC. P.O. BOX 210767 ANCHORAGE, AK 99521 A + Home Services 7501 E. 140" Ave. Anchorage, AK 99516 To Whom It May Concern: ANCHORAGE (sol) 272-4591 Fax: (907) 272-4590 Subject: Septic lift station, Lot 2 - Block 3 Subdivision Spend Love View Heights, 13591 Spend Love Dr. Anchorage Alaska. Ed's Electric, Inc. installed electrical on subject project to the code requirements of the National Electrical Code and the Municipality of Anchorage. Thank you, Dwayne R. Brun Ed's Electric, Inc. rpr-is-PART FRT 08:54AM ID:A* HOME SERVICES, INC. PAGE:1 �r MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW020351 Legal Description: SPENDLOVE VIEW HEIGHTS BLK 3 LT Design Engineer: 0041 AK Water & Wastewater Consultan* Owner Name: Ron Shine Owner Address: PO Box 220829 Anchorage , AK 99522 - Date Issued: Sep 17, 2002 Expiration Date: Sep 17, 2003 Parcel ID: 021-021-09 1 Site Address: Lot Size: 47636 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of. 7 Disposal Field 0 Septic Tank Holding Tank E] Privy Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 12./17/02 PES' IGAl f?lfT,' 15 2.0 C 9 # iV(ETk r�p, 7-6e/4 TO 3.4 9pd1J7 ItU_4(/C/_( /S s T•c Gf v6.orr�( /91_ L 0 tt GOLF_ 6F 4- 9/° 9''lt7 Received By: Issued By: Fh,' •Ok Al . r i Municipality of Anchorage Development Services Department 1i1ii+ Building Safety Division II ° On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLIICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. _ 021-021-09 Permit Number _5WO2035"/ Property owner(s) RON SHINE j Day phone 227-9201 Mailing address (1) P.O. BOX 220829 * ANCHORAGE, AK II� Mailing address (2) 1 Zip Code 99522 Legal description (Lot, Block & Sub'd.) Legal description (Section, Township & Range) _N/A Lot Size �%, �. Ares/Sq.Ft. Number of Bedrooms 4 THIS APPLICATION IS FOR: Sewer Only ❑ Well Only ❑ Sewer and Well Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I, I certify that the above information is correct. I further certify that this ap'Dlication is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. ALASKA WATER & WASTEWATER CONSULTANTS, INC. _Ru: Permit Fees -$400 4150f x`150 � 700' Date of Payment: CO / )d2 -- Receipt Number: fP�l Waiver Fees: Date of Payment: Receipt Number: ALASIZA. WATER �& WASTEWATER CONSULTANTS, INC. September 13, 2002 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 Ref: Proposed Well and Septic System for Lot 1, Block 3; Spendlove View Heights Subdivision ADVANTEXTm TREATMENT SYSTEM To whom it may concern: 1. GENERAL: The proposed 4 bedroom home will be served by a private well and septic system. Four test holes were excavated on the property. We, are proposing to design the septic system around the 30 foot radii of these test holes. Due to high ground water, the limited amount of receiving soils, we are proposing to use an Advantex treatment system and two 5 -wide trench type drainfields. The well is to be located in the area shown on the site plan and design drawing. 2. SOILS: See the attached logs, which shows the soil classifications, groundwater monitoring, and the percolation test results. 3. DRAINFIELD APPLICATION RATE: The intent is to install an Advantex Treatment System that will allow the use of a small drainfield in the area around the 30 foot radii of the test holes. A percolation test was performed in test holes three and four between the depths of 2.5 to 3.5 feet and found the rates ranged from 15 to 16 minute/inch. The Advantex system has received class III approval and we are going to conservatively assume an application rate of 2.0 GPD/FT'. 4. TRENCH DESIGN: a. Percolation Rate: 15 & 16 minutes/inch b. Proposed Application Rate: 2.0 gallons/day/f12 c. Number of Bedrooms: 4 d. Design Flow: 600 gallons per day e. Minimum Absorption Area: 300 f12 f. Total Depth: 3.0 feet (max.) g. M.O.A. Approved Sand Filter Depth: 2+ feet 6901 Debarr Road, Suite 2B — Anchorage, AK 99504 — Ph: (907)337-6179 — Fax: (907)338-3246 h. Effective Depth: 0.5 feet i. Width: 5 feet j. Minimum Length: 76 feet long.(two @ 38 feet) k. Effective absorption area: 380 ft2 5.ORENCO PACKAGE SYSTEM: The STEP tank with the Advantex Treatment System will be manufactured by Anchorage Tank & Welding to meet the latest design criteria established by Orenco Systems, Inc. The point of contact at Anchorage Tank is Lowell McNutt. As with their standard STEP tank, it is equipped with a high water alarm per M.O.A requirements. 6. SURFACE WATER: There is surface water running north to the proposed septic system in a drainage ditch. The proposed septic system is to be installed 100 feet from the drainage ditch. 7. TOPOGRAPHY: The average topography in the area of the proposed drainfield is a 10%- 15% slope running approximately northeast to southwest. In short, there are no slope concerns. 8. CLOSING: I am open to any suggestions from your department that would be an improvement to the proposed system. I am unaware of any negative impacts that this installation would impose on adjacent wells, or septic systems. If you have any questions, please call us at I.S. NOTE. Attached is a site plan drawing, a design drawing, an Advantex detail, a trench detail, four soil logs, a topography drawing, and a 7 page construction specification letter which are all part of the design package for this septic system. 6901 Debarr Road, Suite 2B — Anchorage, AK 99504 — Ph: (907)337-6179 — Fax: (907)338-3246 T12N, R3W, SEC. 25 S2, W2. NWr4, SE4 do NE4, SE4 W N�� /PROPOSED i WELL-, I I l 1 T12N, R3W, SEC. 25 S2, SE4, SE4 NO ENCROACHMENT CONCERNS II LOT 4, BLOCK 2 0 SPENDLOVE VIEW HEIGHTS I I S.- U LOT 5, /BLOCK 2 SPENDLOVE VIEW HEIGHTS Z II SURFACE WATER [PROPOSED ' Q I ( IN DITCH SEPTIC ♦/� VII (TRICKLE) AR_ D PROPOSED II 4 BEDROOM WELL L HOUSE / �+ SPENDLOVE DRIVE -t-------------•f---� /I �TH13 \ - ALTERNATE \, SITE LOT 2. BLOCK 3 SPENDLOVE VIEW HEIGHTS TMJ' Cs'&TTIc AR aD 11 IIIII iIIII N9%0-4THJ*PROPOSED SEPTIC SYSTEM (SEE DESIGN, PAGE 2 OF 4) !L----------------woo—�hd�•—� ' s—•'��, y—� OV— --- T12N, R2W. SEC. 30 LOT 4, SW4, SW4 C�05) 9/13/2002 _ AWN BY. ALASKA. VVATIJR & WASTEXX7ATER SCS Z.T.G. CONSULTANTS, INC. 6901 DEBARR ROAD. SUITE 213 • ANCHORAGE, AK 99504 • PHONE (907)337-6179 • FAX (907)338-3246 PREPARED FOR PHONE NUMBER: PAC RON SHINE 227-9201 LEGAL DESCRIPTION: SPENDLOVE VIEW HEIGHTS SUBDIVISION; LOT 1, BLOCK 3 TYPE OF WORK: SITE PLAN FOR PROPOSED WELL AND SEPTIC SYSTEM 1 " = 100' T12N, R2W, SEC. 30. LOT 4 E2, SW4, SW4 PTN. SE4, SW4 �t •1.. Ai' t tip, mg,"'ll'imow 1 OF 4 Goo ' Je r G rness E— cp< 4�4pr0 If ess10! -- - - - -A - - - - PROPOSED SPENDLOVE DRIVE 10' UTILITY EASEMENT ' IILL TH/3 II_ PROPOSED I i 4 HSBEDROOM i V I PROPOSED 1500 GALLON FIBERGLASS ADVANTD( TREATMENT SYSTEM AND PUMP VAULT I I (SEE DTAIL DRAWING, PAGE 3 OF 4).— \ )-\ o--1112 1112 0 SITE —PROPOSED DRAINFIELDS. EXCAVATE TWO TRENCHES THAT ARE 3 FEET DEEP MAXIMUM BY 5 FEET WIDE BY 36 FEET LONG EACH (76 FEET TOTAL LENGTH). ADD 2 FEET OF M.O.A. APPROVED SAND FILTER AND THEN 0.5 FEET OF CLEAN. WASHED SEWER DRAINROCK. INSTALL, TRENCHES PARALLEL TO SLOPE CONTOURS. THE DISTRIBUTION LINES ARE TO BE 1.25 SCH. 40 PVC WITH 1/4 INCH DIAMETER HOLES SPACED 30 INCHES ON CENTER (15 HOLES PER LATERAL / 30 HOLES TOTAL). I I NOTE. THE CONTRACTOR SHALL HAVE THE EAST PROPERTY UNE FLAGGED BY A REGISTERED LAND SURVEYOR. I \ DATE: 9/13/2002 DRAWN BY: ALASKA WATER & WASTEWATER SCALE: Z.T.G. CONSULTANTS, INC. 1 " = 40� 6901 DEBARR ROAD. SUITE 2B • ANCHORAGE. AK 99504 • PHONE (907)337-6179 • FAX (907)338-3246 PREPARED FOR: PHONE NUMBER: PAGE NUMBER: RON SHINE 227-9201 2 OF 4 LEGAL DESCRIPTION: SPENDLOVE VIEW HEIGHTS SUBDIVISION; LOT 1, BLOCK 3, TYPE OF WORK: DESIGN OF PROPOSED WELL LOCATION AND SEPTIC SYSTEM NOTE: JIM CROSS, P.E. HAS THE ADVANTEX MANUAL INLET - FINAL GRADE --\6' JIB ) 2 AdvanTex" Treatment System: AX20 - Mode la 40x94Pod Orenco 0Y AX20 POD TO PROPOSED DRAINFIELD 8' ABS PUMP—OUT I: j CM.2) i 6' ABS COUPLING 1 ; CLUED T 1 CrM.2, tiIN d� �oROOCKR INLET—I i I ! 1I ORENCID --- ; --- �I' BIOTUBE OPTIONAL I i I I (I i SCREENED I VAULT SLIDE SECTION OF 8' PIPE OVER THIS CONNECTION PROVIDE _ ; i •���•� ' + 3 BEDROOM 11 ', I •� SHEER PROTECTION— EXTEND TO FIBERGLASS TANK i:i C ! + EFFLUENT PUMP BRIDGE EXCAVATION 9/13/2002 o4OF.. s _ ��' --- DRAWN BY: AIIASKA WATER & WASTE, WATE Z.T.G. -�--�� CONSULTANTS, INC. SCAM 4 1 6901 DEBARR ROAD, SUITE 28 •ANCHORAGE. AK 99501. •PHONE (907)337.6179 •FAX (907)338-5246 N.T.S. :.. PREPARED FOR: PHONE NUMBER: PAGE NUMBER: RON SHINE (907) 227-9201 3 OF 4 of e k. G ness. LEGAL DESCRIPTION: (70 o C 7953 o�G SPENDLOVE VIEW HEIGHTS SUBDIVISION; LOT 1. BLOCK 3 TYPE OF WORK: 04°� dp • • o� o0 ADVANTEX PROFILE DO o 0 �Ofessio� o0 40000 0 38 FEET LONG MT ------------------ 0, FROM 5 FEET WIDE 10 ? ----------------- ------------------------j -THE DISTRIBUTION LINES ARE TO BE 1.25 SCH. 40 PVC WITH 1/4 INCH DIAMETER HOLES SPACED 30 INCHES ON CENTER (15 HOLES PER LATERA. / 30 HOLES TOTAL). I Mi ----------------- Q WIDE —1 FROM ADVANTEX 5 FEET I ____.T.SYSTEM I L�-------------------------------------------I 38 FEET LONG FILTER INSTALL BRACING AND STAKING AS THE DISTRIBUTION LINES ARE TO BE 1.25 SCH. 40 PVC WITH 1/4 INCH DIAMETER HOLES SPACED 30 INCHES ON CENTER (15 HOLES PER LATERAL / 30 INSTAL BRACING AND STAKING AS NECESSAR M'T APPROVED I 10• FABRIC P -w 0.5 FEET OF EFFECTIVE 3 FEET DEEP MAXIMUM t; DATE, Opo 9/11/2002 ___� / a1► r _ DRAWN BY: ALA.SK ))TATER & `V'VASTEWATER Z.T.G. `���0� CONSULTANTS, INC. SCALEN.T.S. "' "' •' ' •' • • oQ 6901 DEBARR ROAD. SUITE 2B •ANCHORAGE. AK 99504 •PHONE (907)337-6179 •FAX (907)338-3246 D PREPARED FOR: ' PHONE NUMBER: PAGE NUMBER: O RON SHINE (907) 227-9201 4 OF 4 O "• r A. Ga Hess:' LEGAL DESCRIPTION: 0 0 —79 e Q SPENDLOVE VIEW HEIGHTS SUBDIVISION; LOT 1, BLOCK 3 TYPE OF WORK:°�° ....... •' F.p�i�v DETAIL OF PROPOSED DRAINFIELDS 4�Op'ofes510'r, Ar "ASKA WATER & WASTEWATER G,: ' T y0� CONSULTANTS, INC. ,rr 4 — 8901 DEBARR ROAD, SUITE 28 0 ANCHORAGE, AK. 99504 • PHONE (907)337-8179 • FAX (907)_%M--3248 • WEBSfTE okwrc.eom ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: SPENDLOVE VIEW HEIGHTS SUBDMSION; LOT 1, BLOCK 3, n f r y Gar ss, • �� CHARLES SUTTON �Q'p, E 7953 o�Q PERFORMED FOR: pA�; 2/19/2002 s •., cp0 DEPT 4�d �ofess io�"�� 1 ORGANICS ITEST HOLE #11D0000 2 SOIL CLASSIFICATIONS 1 SITE PLAN GW ���� ORG ED 100' WE RADIUS 3 s, `:� GP ML GM CL 4 GC OL SW MH 5 SP CH SM ,' OH 5 BEDROOAA 6 SC (APPROX. 7 GROUNDWATER DATE ML w 8 CL LENSES/ DRY 2/1s/2oo2 9TEST ol POCKETS �" THROUGHOUT 10 11 DATE READING CLOCK NET TIME WATER LEVEL NET DROP 12 13 14 15 16 B.O.H. 17 18 19 PERCOLATION RATE 240 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 5.0 FT. AND 5.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: CALEB GALL COMMENTS: SITE UNSUITABLE FOR ONSITE SEPTIC. PERFORMED BY A.W.W.C., INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS41.7 AS ERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: O TIME I READING (INCHES) 2 20/2002 1 1:53 I P �I 1 "=100' — 2 2:23 30 5 7 8" 1 8" PROPOSED '�TM 2 HOUSE I Cq -�#1 LOCATION) LOCATIONS ARE APPROXIMATE. TIME (MINUTES) READING (INCHES) 2 20/2002 1 1:53 — 6" — 2 2:23 30 5 7 8" 1 8" .ALASKA 'WATER & �WA.STEWATER CONSULTANTS, INC. 6901 DEBARR ROAD, SUITE 28 • ANCHORAGE, AK 99504 • PHONE (907)337-6179 • FAX (907)3M-3248 • WEBSM ok"ccom SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: SPENDLOVE VIEW HEIGHTS SUBDIVISION; LOT 1, BLOCK 3, PERFORMED FOR: CHARLES SUTTON DATE: 2/19/2002, DEPT ORGANICS ITEST HOLE 2 1 7 e ML w/ CL LENSES/ y. POCKETS THROUGHOUT lo --4 11 12 13 14 15 16 17 18 DEPTH TO DATE GROUNDWATER DRY 2/19/2002 READING ri I! NET TIME (MINUTES) SOIL CLASSIFICATIONS 2/20/2002 1 �I PROPOSED 100' _ I WELL RADIUS 1 "=100' j 2 I 1 30 GW •" GP ML PROPOSED /.%GCHNN • 5 BEDROOM I111111'IMH STH#2 HOUSE op 0 i//iICH LOCATION) i C',�AAp TH#1 S ' � SC 7 e ML w/ CL LENSES/ y. POCKETS THROUGHOUT lo --4 11 12 13 14 15 16 17 18 DEPTH TO DATE GROUNDWATER DRY 2/19/2002 DATE READING ri I! NET TIME (MINUTES) SITE PLAN 2/20/2002 1 �I PROPOSED 100' _ I WELL RADIUS 1 "=100' j 2 I 1 30 5 7/8- 1/8" PROPOSED 5 BEDROOM STH#2 HOUSE LOCATION) i C',�AAp TH#1 S � p '90 THOL LOCATIONS ARE APPROXIMATE. --------------------- _---- DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL NET DROP READING (INCHES) 2/20/2002 1 1:52 — 6" — 2 2:22 30 5 7/8- 1/8" 19 PERCOLATION RATE 240 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 5.0 FT. AND 5.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: COMMENTS: SITE UNSUITABLE FOR ONSITE SEPTIC. ❑ NO CALEB GALL PERFORMED BY A.W.W.C., INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS V4AS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: C? 1 12 /0, ' Imo:., ALASKA WATER & WAS T EVVAZ LR G,: .y0� •� q CONSULTANTS, INC. 6901 ...... ... . .. ...... R ROAD, SUI—TE-9-0 ANCHORAGE. AK. 99504 •PHONE: (907)3J7-8179 •FAX: (907)338-3246 •WEBSITE: okwwc.eom SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: SPENDLOVE VIEW HEIGHTSD; LOT 1, BLOCK 3 0 l of G nes PERFORMED FOR: RON SHINE DATE: 7/27/2002 �4� E 7953 o`p ' tic�0 DEPT 4aie ono (feet TEST HOLE 3 �Opfp`000d�� 1 ORGANICS SOIL CLASSIFICATIONS 2 —-------------- p;'':a':: GW ORG 3 ML SANDYG P M L --------------------- r r--------------- GM CL I I M3 4 GC OL SW MH 5 SP CH THga SM �� �' OH 6 SC ' PROPOSED i`� 5 BEDROOM 7 ML w/ (n DOUSE 8 COBBLES f I �1 �,� LOCATION) oti I � 9 B.O.H. I �� SITE PLAN j 1"=100' 10 11 12 13 14 15 16 17 18 19 PERCOLATION RATE 16 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 3.0 FT. AND 3.5 FT. 20 A PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: ZACHARIAH GALL COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS W UPEORMEID IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 6 DEPTH TO GROUNDWATER DATE 6' (SEEP) 7/27/2002 4'-4" 8/9/2002 7/30 2002 1 1:01 — DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 7/30 2002 1 1:01 — 6" 0" 2 1;31 30 0" 2" 3 1:31 — 6" 0" 4 2:01 30 0" 1 7 8" 5 2:01 — 6" p" 6 2:31 30 0" 1 7 8" �i�i V �Ii�.�V -` � � • 0440 AT .ASKA. AVATER. & WASTE «TATER �,�? ' •�Po ""^^^�*^-STM•^^ CONSULTANTS, INC. ys 6901 ... . . .... R ROAD, SWE 28 • ANCHORAGE, AK. 99504 • PHONE (907).337-6179 • FAX: (907)338-3248 • WEBgfE °k"wcxom D SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: SPEND LOVE VIEW HEIGHTS, LOT 1, BLOCK 3 OD ofI A. am s.: PERFORMED FOR: RON SHINE DATE: 7/27/2002 �0�.�, 7953 DEPTH 44� fo^edProf ess101 o% (feet) ORGANICS TEST HOLE 4 p�D000000� 1 -- SOIL CLASSIFICATIONS 2--------------- d,:o: GW ORG 3 .��•, �'`' GP i r------------------------------------ GM CL 4 GC OL 4TMJ3 ML °o°o o SW MH 5 SEEP @ 5' ': ��.p. SP CH ; _ 4H#4 SM ; OH " 6 SEEP @ 7' SC .I PROPOSED 7DEPTH TO 5 BEDROOM GROUNDWATER DATE HOUSE ' (APPROx. 8 i Cq, O,� LOCATION) J- ti� 9-- ML w/ �'� SITE PLAN NO COBBLES 1"=100' 10 B.O.11. 11 DATE READING CLOCK NET TIME WATER LEVEL NET DROP 12 13 3 1:30 0 6" — 14 15 16 17 18 19 PERCOLATION RATE 15 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 2.5 FT. AND 3.0 FT. 20 A PRESOAK WAS PERFORMED: YES ❑ NO SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: ZACHARIAH GALL COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PER ORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:— eV1 5', 7' (SEEPS) 7/27/2002 DRY TO 10.0 8/9/2002 7/30 2002 1 1:00 0 TIME (MINUTES) READING (INCHES) 7/30 2002 1 1:00 0 6" — 2 1:30 30 4" 2" 4 2:00 30 4" 2" 5 2:00 0 6" — 6 2:30 30 4" 2" :2 HEIGHTS RM, SE(% 14. SE4 do r� •i 3LOLLE Tl 2N, S2, " 25/02 4�p o DRA ALASKA WATER & WASTEWATER "'• :� 0 CONSULTANTS, INC. 6901 DEB RR ROAD, SUITE 213ANCHORAGE. A 99504 A PH NE (90 11337-617 • FAX (907)3 46 _ •� PREPARE FORPHON NUMBE NUMB CHA LES SUTTO 269 1161 OF W 0�4fc • •: o� ' LEGAL DES ON:Q SpENDLbVE VIEW �B H IGHTS; LOT 1 OCK 3 •. Q P--• • es , �0 Op • A�cvv PE OF W SITE ORK: PLAN I o Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.munl.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS 1*2 V APPROVAL FOR A SINGLE FAMILY DWELLING CC ' Parcel I.D. _D �-0 a/" b 9 COSA# 6 6Iff tD 1. GENERAL INFORMATION Expiration Date: - 1 "' S Complete legal description SPENDLOVE VIEW HEIGHTS S/D: LOT 1 BLOCk3 Location (site address) 13591 SPENDLOVE DRNE, ANCHORAGE AK, 99516 Current Property owner(s) RON SHINE Day phone 522-3889 Mailing address 13591 SPENDLOVE DRNE, ANCHORAGE AK. 99516 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site 0 Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not resppnsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my. to Systems Approval Guidelines for this application, investigation, based on procedures outlined in the Certificate of.On-Si shows that the on-site water supply and/or wastewater, disposal system is (are) safe, functional and adequate. for the number of bedrboms and type'of structure indicated herein. I further verify that based on the . informatit5h obtained from the Municipality of Anchorage (les and from my investigation End inspection, the on-site water supply and/or wastewater disposal system Is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. . ' Name of Finn GARNESS ENGINEERING GROUP, Ltd. Phon.6 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 *.ANCHORAGE. AK 99507 Engineers Printed Name JEFFREY A. GARNESS, P.E. -Date S t 5. Engineers Comments:. In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines 8 Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory that test results do not guarantee future performance of the system, nor do they guarantee there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party Is not authorized, nor will it confer any legal right whatsoever. DSD SIGNATURE _ Z Approv Conditional approval for Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory bedrooms, with the flowing stipulations: Arsenic Advisory Maintenance Agreements Supplemental Engineers Reort Other By: Original Certificate Date: (Rm. 11105) VVHI CR r%~ WASTEWATER PROGRAM Municipality of Anchorage , Development Services Department ° Building Safety Division' On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: SPENDLOVE VIEW HEIGHTS; LOT 1, BLOCK 3 Parcel lD:O:Z1-fl2./—Oq A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID# N/A Date'completed 11 /16/2002 Sanitary seal (Y/N) YES Total depth 208 ft. Date of test Static water level Well production Cased to 51 (BEDROCK) ft. FROM WELL LOG 11/16/2002 WATER SAMPLE RESULTS: 0 ft. 3.0 g.p.m. Well Log (Y/N) YES Wires properly protected (Y/N) YES Casing height (above ground) 18+ in. AT INSPECTION 5/13/2008 24 ft. 1:7 g.p.m. Coliform _Q_ colonies/100 ml. Nitrate _4S.4g./L. Other bacteria 10 ml. Arsenic: �_ ug./L. Date of sample: 5/1-3/2008 Collected by: GEG Ltd. B. SEPTIC/HOLDING TANK DATA Tank,Type/Material ADVANTEX/FIBERGLASS Date installed 2/25-28-2003 Tank size 1500 gal. Number of Compartments 2 Cleanouis (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) YES Date of pumping 5/15/2008 pumper A+ HOME SERVICES SIN Sp_ G-t�oNl C. ABSORPTION FIELD DATA BELow EXISTING GRADE Date installed3/25-28/2003Soil rating .p.d./ r ft'/bdrm) 4_0 System type ADVANTEX Length 40 ft. Width 5 ft. Gravel below pipe 0.5 ft. Total depth 2.9 ft. Eff. absorption area 200 ft' Monitoring tube YES Depression over field NO Date of adequacy test 5/13/2008 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test DRY in. Water added 600 gal. New depth 2 in. Elapsed Time: 5 min. Final fluid depth DRY in, Absorption rate >= 600+ g,p,d, Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes,'give date - D. LIFT STATION *INSPECTIONS PERFORMED BY A—PLUS HOME SERVICES 5/15/2008. Date installed 2/25-28/2003 Size in gallons 81 Manhole/Access (YIN) YES "Pump on" level at TIMER in. "Pump oft" level at TIMER in. High water alarm level at 46/44 in. Datum BOTTOM OF TANK Cycles tested "3 Meets alarm & circuit requirements? YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ Absorption field on lot 100'+ Public sewer main N/A On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Sewer /septic service line 25'+ Holding tank N/A Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5' Water main N/A Water service line 10'+ Surface water '55' Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line P 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water "65' Driveway, parking/vehicle storage ' 10'+ Curtain drain NONE KNOWN Wells on adjacent lots' 100'+ F. COMMENTS *SURFACE WATER PRESENT IN DRAINAGE DITCH. PER OWNER, SURFACE WATER IS NOT PERMANENT. SEE ATTACHED DRAWING. G. ENGINEER'S CERTIFICATION I certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date 0140 8 COSA Fee v Date of Payment 5 �� Receipt Number 7� (Rev. 11105) Waiver Fee $ Date of Payment Receipt Number SGS Ret.B 1082025001 Clicnt Name Garness Engineering Group, Ltd. Project Name/# Spend Love View lits Ll Iia Client Sample ID Spend Love View lits LI B3 Matrix Drinking Water PWSID 0 Sample Remarks: All Dates/Times arc Alaska Standard Time PrintedDate/fime 05222008 15:18 Collected Date/rime 05/132008 15:30 Received Date/rlme 05/132008 16:20 Technical Director Stephen C. Ede Allowable Peep Analysis Parameter Results PQL Units Method Conaim ID Limits Date Date Init Metals by ICP/MS Arsenic Waters Department Total Nitmte/Nitritc-N Microbiology Laboratory Colony Count Total Coliform Fecal Coliform ND 5.00 ug/L EP200.8 C (<to) 05/14/08 0520/08 NRB 4.35 0.100 mg/L SM204500NO3-F B (<10) 0521/08 LCP 0 col/100mL SM209222B A (<200) 05/13/08 DLC 0 coUl00mL SM209222D A (<I) 05/13/08 DLC 0 col/100ml. SM209222B A (<I) 05/13/08 DLC PERMIT NUMBER: SW020351 AS -BUILT DRAWING PARCEL 021ID-0211-09-09 021 1 SPENDLOVE DRIVE I WATER FLOWS �/ 7HR000H CULVERT -LARGE PUDDLE. SLOWLY DRAINING cy� O9� /4 GARNESS ENGINEERING GROUP, Ltd. A.J.G. CONSULTANTS d GENERAL CONTRACTORS .....,.... .•.,,,.,., SCALE: lml L 11.0011 fONA fort 101 • MtIgMGT, NI fqM . MOMf N • EPARED FOR: PHONE NUMBER: PAGE NUMBER: RON SHINE (907) 522-3889 1 OF 1 ;AL DESCRIPTION: SPENDLOVE VIEW HEIGHTS SUBDIVISION; LOT 1. BLOCK 3. 'E OF WORK: DETAIL OF SURFACE WATER LOCATION DRAINFIELD I A I 8 I STI 10_UT14RY 40.12 POD 62.11 39.63 MH1 66.36 39.70 MH2 71.87 40.07 MTI 47.90 30.24 MT2 81.28 II I I� � NEW 4 BEDROOM HOUSE 47N�7 / ISI 8 A / FCO I WATER FLOWS �/ 7HR000H CULVERT -LARGE PUDDLE. SLOWLY DRAINING cy� O9� /4 GARNESS ENGINEERING GROUP, Ltd. A.J.G. CONSULTANTS d GENERAL CONTRACTORS .....,.... .•.,,,.,., SCALE: lml L 11.0011 fONA fort 101 • MtIgMGT, NI fqM . MOMf N • EPARED FOR: PHONE NUMBER: PAGE NUMBER: RON SHINE (907) 522-3889 1 OF 1 ;AL DESCRIPTION: SPENDLOVE VIEW HEIGHTS SUBDIVISION; LOT 1. BLOCK 3. 'E OF WORK: DETAIL OF SURFACE WATER LOCATION DRAINFIELD I A I 8 I STI 58.31 40.12 POD 62.11 39.63 MH1 66.36 39.70 MH2 71.87 40.07 MTI 47.90 30.24 MT2 81.28 36.14 0 Z 0 7d. U SPENDLOVE VIEW LOT 68-57 HEIGHTS SUBDIVISION 1, BLOCK 3 47,636 S.F. SPENDLOVE DRIVE N N 90000'00"E 139.00' W Z 4 \ IWI C I I % I�1 GASTALDI LAND SURVEYING, LLC JEFF A. GASTALDI. R.L.S. 2000 E. DOWLING RD., SUITE 8 ANCHORAGE. ALASKA 99507 PHONE 248-5454 GRID2942 I D5/6/2008 F.B. JOB NO. 08-03 SVH13 10' UT1L ESWT. . - S 89048'21"E 159.00' I HEREBY CERTIFY THAT 1 HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO ENCROACHMENTS EXIST EXCEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES. ANCHORAGE RECORDING DISTRICT, ALASKA NOTE. NO CORNERS SET THIS DATE 59.8' O M Ti ..r 111=30' .♦♦10LU 11. 4W "Z;:.•OF••.q4gs ar �: 9 ;. ..49TH........: * i A. ' Jeffery Idl : g ♦ �� :� LS -6091 �0jeaalo0ol L° WELL I I I I CONC. ORNE I I 3_0.0 DECK i STOOP I I 1 18.0' I I b I I I EXISTING BUIL.DINGN I 32.0' I I I 1 I I I I 16.0' I I I I • SYSTEM 1 y�SEPTIC \J• I • Do O1 I I N I I \ I 1 W Z 4 \ IWI C I I % I�1 GASTALDI LAND SURVEYING, LLC JEFF A. GASTALDI. R.L.S. 2000 E. DOWLING RD., SUITE 8 ANCHORAGE. ALASKA 99507 PHONE 248-5454 GRID2942 I D5/6/2008 F.B. JOB NO. 08-03 SVH13 10' UT1L ESWT. . - S 89048'21"E 159.00' I HEREBY CERTIFY THAT 1 HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO ENCROACHMENTS EXIST EXCEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES. ANCHORAGE RECORDING DISTRICT, ALASKA NOTE. NO CORNERS SET THIS DATE 59.8' O M Ti ..r 111=30' .♦♦10LU 11. 4W "Z;:.•OF••.q4gs ar �: 9 ;. ..49TH........: * i A. ' Jeffery Idl : g ♦ �� :� LS -6091 �0jeaalo0ol L° MAY -19-2008 09:276 FROM: 70:18663847404 P:6r7 0 n a n. ■■■■ ■ ■o a ■■■■■ ■ ■■■ ■■■■■■ Field Maintenance Report Inspection 102 900 ■■■ ■ ■ ■■■ ■ ■ ■ ■■ ■ ■■■■■ ■■ ■ ■ ■ ■ Ron ■5 l ow ■■■ ■■■ a. AnchorageTank & Welding, Inc. 907-272-3543 error i' Ron Shine PH (6.9) Do a-6) ins aeae.. 9raprpTondlna comm rron 13591 Spendlove Drive, Anchorage, AK 99516 Pr Ajd (907) 5223889 ax ah. n s Ce.ey,o a tae s nru.nti. save beu AX -100929 021-021-09 200855 RTU101620 06/032003 Retrieve O&M Into Daily now -- ReWc ratio TimersolUngs: Recirc OH Cycle Time -19.5/min Recirc On Cycle Time - 0.5/min Perform Field Sampling/Observations I" ns a unw PH (6.9) Do a-6) ado 9raprpTondlna t5wlwwww ❑Excessive Dow of samNo typkud Lviouty ❑Earthy ❑moldy Herrtypicar ❑Syhide ❑Cabbape ❑Decay OlysbnnPW ❑Yes ONO Foam stank ❑Yes ON* Check Control Poul Ibolro Amps DifCharya Amps Audible SM Visual stars UOK �/ Dial to"0wometry oNy) Oyes l'liro InspecUClean Pump System aspect clean RiWAJd .................... Irk Span Box ....................' Fleat Cords ................... Floats ........................ / U/ Pump ........................ 6lotub4e Rnar................. C elotube Pump Vault ............ _VJ/ Radmula ft SplMer Vatm....... I,�I Comments Measure Sludge/Scum sludge 111 t lstca putmenl current prl'Aws Currant PwAfto 2M Canpanment Currant Provleus Curom Prwloue Inspect/Clean AdvanTex Fitter odor. m(m+ npun9.s ekxnat EI OE.«s>~. 9raprpTondlna t5wlwwww ❑Excessive Inspect/Clean Discharge Pump System Irspect Pr Ajd ❑ $plies eco ❑ Fiw cords ❑ Inspect/Service Other System Components respect Clean Coe n ❑ I senora U zea" O Intake vent ❑ ❑ h:pect Clean Hosts ❑ ❑ Pump ❑ n Irwpel peon Cl-oIci Clean D,sinfeelan EQuiprW nant U ❑ Dispetstsrak/Orincea ❑ Additional Services Rendered UClesnedlexdleshests? [)nepler&d Wneme? ❑ Replete Miuld ~ Meme? Fina telly Inspection e yLddOn /MRMlwdwonmaCeO; aYN VWea eJpead ,LK-,CO/nUOl panel lOeptivatad / sum rtyry/Recommendatlo ne Treatmatt ayetom to psnorminp; ❑ Call for service no/ynhar actlm Mgsuty. ❑TMkneedspumpinp ❑ other? ->`'o has -'aK mgchryie S*d he WrY/ Dale Fax completed form to 1-866-384-7404 %"e ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT MEMORANDUM OF UNDERSTANDING BETWEEN MUNICIPALITY OF ANCIIORAGE AND THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this (o Day of ? y : Q of 20 OS by and between /Z f i- &m -IS herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to this Memorandum of Understanding agree as follows: 1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as A located at S'pp eq cl /e U Mu r k 3, Anchorage, Alaska. 2. Definitions. /_ oT A. Alteration. Any change to the design or function of an AWWTS that Includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Prior to performing any alterations to an AWWTS the owner must obtain a Wastewater Disposal System Construction Permit from the Municipality pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65. B. Certificate of On -Site Systems Approval. An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with AMC 15.65. D. Owner agrees that only maintenance, repair personnel certified by the Municipality will inspect and make any necessary maintenance, repairs or permitted alterations to the system. E. Owner agrees to grant the Municipality reasonable access to test and inspect the AW WTS upon 24 hours written notice. F. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. G. O%%mer agrees that the relevant provisions of the standard specification guidebook for AW WTS is the governing professional guidelines for the construction, maintenance and repair of the Owner's AWWTS. 7. Nomvaiver. The failure of either party at any time to enforce a provision of this Memorandum of Understanding shall in no way constitute a waiver of the provisions, nor in any way effect the validity of the Memorandum of Understanding or any part hereof, or the right of such party thereafter to enforce each and every provision hereof. 8. Amendment. A. This Memorandum of Understanding shall only be amended, modified or changed by a writing, executed by authorized representatives of the parties, with the same formality of this Memorandum of Understanding was executed and suchwriting shall be attached to this Memorandum of Understanding as an amendment. B. For the purposes of any amendment modification or change to the terms and conditions of this contract, the only authorized representatives of the parties are: Owner: Anchorage: Purchasine Officer C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of Understanding shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govem the rights and obligations of the parties under this Memorandum of Understanding. 10. Severability. Any provisions of this Memorandum of Understanding decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Memorandum of Understanding. OWNER: By: �liri Date: Tie 1 ad18 MUNICIPALITY: By: Title: Date: STATE OF ALASKA ) ) ss. THIRD JUDICIAL DISTRICT ) The foregoing instrument was acknowledged before me thissri day of 20 L, by Todd l oomit , the OWnGi� U J�� /I � 'L VOT Y PUBLI FOR ALASKA OFFICl/ALSEAL hmia My Commission expires: if'Z1i /D N=0®rusuc Mr hiJn4NY ROSE DAY m tot 2 40 pot tz lo 41 2 14 11A I 0� \`- . ♦ \ � y .aid". v1 ' p..lr t t r ,vi r .''�✓o �>,;I .:�\ .pry,. \ .. +.�"'� � 1 'i lam' + ^e ♦ � aC 4�' � > > �: . +, ;1 ; .r+,\7•t rl��'�/.__a �r �y1,'1t. 11! ��ti + �' s , f_,` 4 J laj t.: } r er a 7•, :1 r ����� 'i � �i+\it } :- a -'1 ' ;,, ..� • � i .1 r. —�. " ' 4� as 7-1 RV • Y . 4 � r ( •t �1 ql r • htq,, t Al r `•. t K' i� r �, �y^.lY ,tea L:'� 1.�, 1 'y t r1', r _ ... .. . r �i �`♦ _: .�L L'Y'Z y�+�\'a a t!'i r�`f r1 a/J l•k• r1� i t'- k.�< ` ` \ a>/+a ..tom '/�J rr�`r A'r.�i.a. ♦_y/ >'\w1a ",\ �.. `• �...`, 1 f ! ti,b Jl r{>� ��y +r.;�A F \'^/i'/ { T � w 4. /FY 1. ., ,fin 1r a /. / r/Z .i ->'�41 X11. > •� ��Y ,'r _�.Sy z •'r i :.., � • Y r \:� �"4 � J. 1 / \ � S' ♦ i i.� � y a t (�` ,, a./+ a 8 s � ^' ...p S `� �I . ri 1 L. ► "lt ` ` ra� �..r ,Y ',1 ;� <aa1 1.~I ;. J•` rr � X15 a i•.\'i 01' // `.y1r `�• �t if r•yy`► ��\ ) i.� ; > ?i"' .y'rr j�✓\�..-. ; n r ,1♦� 1 "C -... r✓ ' f..y w �l/_ f) i r } .' n +r 'a, 1 t r f rn 1.` i I.t� eja .. "?�a '.✓a �i �\,.�r .+, rf �'.r yq �'..' t<.,�• +} _a j . 1 '" ♦..� � 'a. +\ a �M �` � ,.l a " 4 I a7:.R :]ry ¢� r � to F+�.. �f+'. • + ! ,:r Pptl /.w.ry 1">1�,'+.,\�'�. y'rx�tla/a h•a 1 t `yews C ?~ tV . >> �•` •. - t - S ,. l �.." ,�+ w r 1. � , 1•a :"( Y _. � • { . a •r »w I!< > a', k / `a Ir ilk 4.1� M-Klamawl§&Aj A IN : fl� Ut ilk 4.1� M-Klamawl§&Aj A IN ♦ '. r ♦ ♦ �`,4 • _ pr's\\7 4j `, 1L�L -, ♦ ! , ,�ii , .�,4 rr 1.� r: k r•' ,+5 . • - `-Y \ \'a L 4 .� 4 rpt , 'O 1 ` l� r 4•: , s 1 a i .: !R� 1' Y ,IN V1 .e* q. Y,;. .':L.ix \i' �Y r i♦ii n� ♦.Li,a +t. ''4' 4:, +. , 'w t ^` '+►_' --+` � �• y \ � *na x 1. j, r 777 fir'•, •.. ` Z v i _ ♦� d aC 4—• � ' . , y. 1 `J :w 1`t 'i' r . Y � �: - w • C ! 1 1' `F,`\ r}. 1 IN:VI \� �!. , •4rr0 ,} ice+.;• <•_'LI*�i it~„1eL1�4\i\\iS.]• \i\.♦�71��N1 •'. \ 4 ��' f \ i� ! v � CYT .� ^ � ^ r I �"� i' -`t` .'(,. L m '� , ,.s. e ' - ♦ LL `•� ���LL �F ♦—�3L'', i^� ( W� ^ j`Yt; n.ii, t�. ��3 r � is • ; .f-' ::�, ` :�. O ,�1�..�� e���t �� ,�ti 1t1+��,ff �,z Y l ��I3' S,,� ,1i 1 -^ . � i r ��� \ V ��R.� 1 , 7�' n+ r af�'-♦T,y 1 +.Tr-_. a \e,T�..T aAS r ti. J , , -. Y , � � S• `♦ ., ♦ •, \Ya\ + . ,� �♦ 1 ,, k�'�w�� t �4 ` i.* 1 >�i�a.t . t•a +• L I ! /j — \ �\.'t —�_ •'�: R �"1�.1.'Y +1 � �')y.�1Rw�,. u7 �"'.l ""`> kT +;EI i/.i�x..�? ~ i ..-.. �,"+f ZI y r� " �,' i L \ 1 ♦. .I . r �: �/ .f' ,4L r 4 i4 t ,ty1ct `�� •.,rte �a � . if F t .� yy'� r i ; IrO ,Ar`��`y f... AY > •i V�� ��'!1 i 4! i. 4 f 'r J��' it✓=' w '/ ! v - � 'h., • - r, �� ` • { Ar `i- 'il �- �! L i y�1� i l��{ /;rT �\ � � ♦ "• �\ + Z i. e5��f� f �F;. w �C ,Y•♦ , Y . :•. IN iVl IN IN .. 4.\ • #♦ S a.•.r� �(`, i �� f.. il. �-i :p �� � •� r> rts.. c ,�` y `M•1Y� !\r i �,. '.: } ti♦ �, ��, A tlJ vi',., � �� 7 ii i r � s- ,:. r� t�- I, 7, k ;�.� 4 �,. LI ,�'r4't• w ...� ♦;+I r .J � 1' , r � t v.� l- 1� ,a 4 r;\` i' , r r' -. \ 1~ •Cid i lf` � it^' .+, i, �, � �� �i ,i• -- �.� � v'>.._,. i r♦w /'rli�/fli�LT �.=_"^� M`�!' , (! -.�l •r r ( l`•}, y. ��. a \ �' v ♦ 1` ` a`¢p/� .� �• h 1,r 3' , y Vii\ .I \ •y, �- +j1' I' Fes' ,� - •., t ,f^' ON Pic '. � f��� A YrYi' t.. :.v'♦T,r,S� �• ) V 1} e+ / '.I7 l � T \..t .�1�>11,, � � \\�• � yT (�'•'� r. `r tir �I `J�x'ii ��r: 'r \�1 ” .. t'i ! �cn ' ( r ,� N �. . Y 1 � ,� w I yi�i•.` •.t/'r I ,� ,rn'i- 1 Rte° j` �...,, - � ? ..�♦, i �- ;`?. � -ii.. r%t7 ,. ,, \�;� �. �,'i „\t,.: l� i'S+iA" �i«\y`:_ �•� "f •" .' 1.� ?Z jlhlw\ •.1 i ;, :. •�r.i. � �-'�...m /� -• " !•• ,' ��. •Lx - ,!«w\ - !f.' •rf'.4 '!r ," �.. Irftn s'/�rr •~r+•!6, wl �.. S�,i. 1 r«,/r}i s �',Yr IJ•1 r{ ri ./e � jly � \M iif +r.�". 1 a 7 �`. f'l Ik R-• )1 ��ir`(T q,�.i: }'at. ♦ -7:. _ •C i` ♦ F�>a, t'J ..J C. y', r � (r� r 1 r I A A.fi •v a} r 1 ♦ h �� •".. ,� 1 i.•t,,i« 1" �`v�f } j �a+r � .}et s1J� �' f .v r^ 1 t\ �. r� { } 4 � � (f t_ ,.- •f \ } a.,l • ,� T x r ! �r 1 3 / l '. •v.. . \1 � �•'�t 5! +. ♦ ri =.t`,K ;.v,!\ r( ti,s ` ( TM{.. /xr � . + f � � � T f..• � 1 9 -, ,J:,.•�1�j k'�+t(" t,�,ii,tldr 7 ��•. i'<}- .el �(�• r � ��+� +� , " � Pt, f, `'•,�11 J 91y Y J r•! i %! ♦ ! •} C / • Jt!' " w fl'f s: �eYrf� ��\�� l•1x .. ,. "moi Y. u� 1•i I F �� �-� �r i" ;; •{t'�J. f,r,�, r, ,..� :.. ,c;T. i ( . "( \ A � � �4 7 T + . � I f '• } • , r T . 1 sl. \ S � :, }� ' 3 - / • J •{ � A i � Y A ..._ �` y _ 1 Gr Aii t r •J�i l-i�t rl " ..a v G it, f` e1 �r,"7 �. +1 �"n1` - • �' i i. � ! 1 11 iJ � (K J : cl .r I ``; ✓f f• s' r r +rt.d11�.�i 'f :�' '!f'4 vr1; rA�T\•1\ 'r, fr ` Y_� ,,.,1 r �• D `'- °. r a -� \k\. $ � ti. \ i 1 J ' r� �I J^ � Ii "7` h�+fa } r iy �'Y •, r•i,i• .il;(�rrl, Al. `•; Iv rsR'x •, .. . �•1 � ,+'A * —'*�}}5 i f !�)? '\ w y ��� ti .. y `: + (e�.w � 4. .r- � �`G � l�i ('i� t i.1:�1 !(r J � two � 1: J�• f ` 3 , jjii td at ���/elir4.sJy f �"� r •f: ! r: �ir 1 a�Yi Y- * '" (f . 1 r - ! !\JX,p � � d+ •rt a r .'•.. .'. R •' r.., �•�1 ••'� �1 • .. .• _ J yq..;��5 Y�' � � tea' I . n r �. fJ ; ^1•`4 ;�=r.� f'•3- '.�r,'f9 g. \r 3 \ .i r:,. ,�, i �u'� S L�,_ r �y r ••rrte+ y i . r ♦ . � � w.J " ; �� y w fIP •� / . ., t T IJ •,,r tf �"'y+ • .% r i �•1r(_w+"fI,l�, ir" ^�..I T.. f� l".�J .! r� i Y 1 _; �"! v ti to R•�„ -•w " H i.l Y ; rki a r , =01 wit, 1 01, LZ ........... ----------- 71 01; Iy Vit ty t'1 0. =01 wit, 1 01, LZ ........... ----------- 71 01; Iy Vit ty t'1 or— I m 1khmicipality of Anchorage CO. Da 1!Mifii(1 - Anchomgc, Ahtskn 9!LSI9'fI:50 • 47M INiorc Hied " 011ier: (tX)7) 333 -MI • Fax. ((M)7) M go -M h1111:II1 im.n1U111.org Mayor Mark (3cr)icll Dcvc1opmcnl Scniecs Department June 25, 2008 Jeffrey Garncss, P.E. Garness Engineering Group 3701 E. Tudor Road, Suite 101 Anchorage, AIS 99507 Subject: Waiver Request for Spendlove View I[eights, B3 Ll Waiver Request WR#: 080037 Parcel ID 0 021-021-09 IIA080161 Dear Jeffrey Garness, P.E.: Ment , Sc i �r Department Your request for a waiver of the required 100 feet horizontal separation from the absorption field to the surface water has been approved. The approved separation distance is 93.0 feet. A waiver of 96' from the septic tank to surface water is also approved. This waiver approval applies to the existing absorption field and septic tank to surface water separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, &49-lit/U Deb Wockenfuss Civil Engineer On -Site Water & Wastewater Program Col)1112u11it1/, Security, Prosperity Municipality of Anchorage Development Services Department Building Safcty Division On -Site Water and Wastewater Program 4700 Bragaw Strcct P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.anchoragc.ak.us (907)343-7904 Waiver Review Worksheet WR#:080037 PID#:021-021-09 HA/Permit# 11A080161 Date Received: June 25, 2008 Legal Description: Spendlove View Heights, B3 Ll Engineer: Jeffrey Garness, P.E. Garness Engineering Group 3701 E. Tudor Road, Suite 101 Anchorage, AK 99507 Applicant: Ron Shine Waiver Requested: 96' from tank to surface water and 93' from absorption field to surface water Criteria: Geology Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Total: I .... mass ... seen ... some ... some .... eggs .................... age... ease.... an Waiver is Granted: X List Conditions or Reasons for above: Waiver is not Granted: Date: 06/25108 By: Deb Wockenfuss Name of Reviewer $..does ... .....................Gess............ aeon .... ................... Rec#: _ Amount: $_ Dale Paid: 612512008 GARNESS ENGINEERING GROUP, Ltd. = CONSULTANTS & GENERAL CONTRACTORS —=� -� June 10, 2008 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Spendlove View Subdivision, Block 3, Lot 1. Waiver of Separation Distance Between the Septic Tank and the drainfield to nearby surface water. The existing four (4) bedroom house is served by a private well and septic system. The septic system was installed in the winter of 2003. The soils testing (summer 2002), the design, and the installation inspections were performed by GEG. When we performed the soils evaluation (summer) and the installation inspections (winter), there was no water within 100 feet of the septic system site. Recently we were retained to obtain a COSA because the owner is selling the home. During our COSA inspection we noted standing water in the road ditch, fifty-five (55) feet immediately downhill of the drainfield (in ditch on Canyon Road) and also noted water running along the west property line (97.0 feet away from the tank and 94.0 feet away from the drainfield at the closest point). Yesterday we performed an additional site visit, and it was noted that the water in the road ditch immediately below the tank/drainfield appeared to be drying up fairly quickly. It is our belief that this water will be gone within a week or two, leaving only the water along the west lot line (which discharges out a culvert that cross to the southwest under Canyon Road). If the septic system were to overflow, effluent would flow directly down to the ditch on Canyon Road and flow to the northwest (in the road ditch) to where the water running along the west lot line discharges via the culvert under Canyon Road. The path of travel for migrating effluent appears to be greater than 100 feet. Further justification for granting a separation distance waiver between the septic system and surface water is summarized as follows: The septic system is a CAT III Advantex system; therefore, the effluent is highly treated. The BOD and TSS numbers for Advantex effluent are typically less than 20 mg1L. The Advantex system is equipped with a high level alarm and the Vericomm monitoring system, which will create an alarm condition and alert the service provider in the event of a high level condition in the Advantex tank. In short, a high level, or overflow condition in the septic tank cannot go unnoticed. Attached is a topography drawing of the area. The topography is such that overflowing wastewater from the septic system would not flow directly towards the road culvert. The path of flow from the tank or drainfield would be directly downhill to the closest road ditch and then northwest (in the road ditch) towards the culvert. The path of travel from the septic system to the surface water would be greater than 100 feet. 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507-1259 Ph: (907) 337-6179' Far: (907) 338-3246' Website: www.garnessengineering.com Based upon the aforementioned facts, it appears that there is minimal risk associated with granting the following separation distances: Septic tank to surface water: 96.0 feet Drainfield to surface water: 93.0 feet please contact us at 337-6179. Thank you for your assistance. VI.S. 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507-1259 Ph: (907) 337-6179 0 Fax: (907) 338-3246 • Website: www.gamcsscngineering.com PERMIT NUMBER: AS -BUILT DRAWING PARCEL ID NUMBER: SW020351 021-021-09 SPENDLOVE DRIVE 10' UTI PY EASEMENT NEW 4 BEDROOMTM13 HOUSE 4 / )CO/ 6 / _ i H14 —E PUDDLE. SLOWLY DRAINING c 9�rOiy TTN/ I \�O q0 OATS: (p , p� DRAWN BY: GARNESS ENGINEERING GROUP, Ltd. A.J.G. CONSULTANTS& GENERAL CONTRACTORS SCALE: 3nI L Rmo.. ll a mi F" M7!u4-M" I" = 40' PREPARED FOR: PHONE NUMBER: PAGE NUMBER: RON SHINE (907) 522-3889 1 OF 1 LEGAL DESCRIPTION: SPENDLOVE VIEW HEIGHTS SUBDIVISION; LOT 1, BLOCK 3, TYPE OF WORK: DETAIL OF SURFACE WATER LOCATION GRAINFIELD STI 58.31 40.12 POD 62.11 39.63 MH1 66.36 39.70 MH2 71.87 40.07 MTt 47.90 30.24 MT2 81.28 36.14 r. P ,Je r y A. Orn s. CE7 oh .. �.e '_04 � �N-Du.(�'S'