Loading...
HomeMy WebLinkAboutROEHL #1 LT 14Roehl #1 Lot 14 020-092-89 EXPIRED PERMIT ROBERT C. COWAN, RE. ROBERTA. SHAFER, RE. Date: CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 HEALTH ALffHORITY APPROVALS SEWER&WATER MAIN EXTENSIONS ' SEWER & WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOILTEST I~ROOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ON SITE WASIEWATER ~SPOSAL S~STEM DESIGN Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 L Street P.O. Box 196650 ~nchorage, Alaska 99519-6650 RECEIVED JUN 21 1999 Municipality of Anchorage Dept, Health & Human Services The septic in.spectiQns for the re~f~erence, d property were performed on 6--! ~--~ and ~-[~-~W. Prlor to submitting the On-site Wastewater Disposal System~afid./o~,~ell Inspection Report we are waiting for the /~5-~,/~jf~4,'Ufy to be completed. If we may be of further service please contact us. Sincerely, Robert C. Cowan, P.E. 17034 NORTH EAGLE RIVER LOOP ° SUITE 204 * EAGLE RIVER, ALASKA 99577 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Sei~ices Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Nov 13, 1998 Expiration Date: Nov 13, 1999 Permit Number: SW980441 Legal Description: ROEHL#1 LT 14 Design Engineer: 0003 S & S Engineering Owner Name: Rick Koso Owner Address: PO BOX 11 KING COVE, AK 99611-0011 Parcel ID: 020-092-89 Site Address: Lot Size: 47116 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field J~ Septic Tank J'-'J Holding Tank [-'J Privy [~] Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: '-/~~" ~ Date: ROBERT C. COWAN, RE. ROBERTA. SHAFER, RE. October 30, 1998 CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 HEALTH AUI'HORITY APPROVALS SEWER&WATER MNN EXTENSIONS SEWER & WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW lEST SITE PLANS ROAD DESIGN SOILTEST PERCOLATION lEST STRUCTURAL & MECHANICAL INSPECTIONS ON SffE WASTE'WATER E~SPOSAL SYSIEM DESIGN MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 REFERENCE: Lot 14, Roehl Subdivision Request you issue a permit to drill a well and install a septic system to serve the proposed two bedroom house on the referenced property. Three test holes were excavated and percolation tests were performed. The approximate location of the test hole is indicated on the attached site plan. The monitoring tube within the testholewascheckedand t,,,a.r,lh_ ~v.,,~s ~:o,~~o ~ ~,v '/'... ' o,~ ,~ l o The property has enough area for a future septic upgrade which can be seen on the attached site plan. We do not anticipate any adverse effects on neighboring wells, septic systems or drainage patterns by the installation of the proposed septic system. There are no points of contamination within the proposed well radius that can be seen on the attached site plan. If you require additional information, please contact us. Sincerely, Robert C. Cowan, P.E. RCC/srj Enclosure 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 ' I I 0 m~ o ~ ° ~ _~o ~ GOLDEN VIEW DRIVE z.-i -- o~ --' r~;O ~ ~m 003 ~Zo o~ z~ PERFORMED FOR: LEGAL DESCRIPTION: Municipality 01 Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L' Street. Anchorage, Alaska 99502-0650 SOILS LOG m PERCOLATION TEST DEPTH 1 / 2 ~ 3 4 7 / ~ 0 ~o / 11 / 12 13 20 .......... iENGINEER'S SEAL) · ":: · "' ~' Township, Range, Section: SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? Depth to Water Afte~,~ /~/, / q ~'' ' L IF YES, AT WHAT ~' O DEPTH? P / Gross Net Depth to Net Reading Date Time Time Water Drop - ,~lO to~,,, l~/¢" V~" PERCOLATION RATE ~--.>'Z~,~ tminutes/inch) PERC HOLE DIAMETER '~ '" PERFORMED B~;a.glo ~Jver J~l../:_ ~ .... ¥ THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDE N THIS DATE. DATE: 72-008 (Rev. 4/85) ~HEALTH AUT HOR~TY J ROBERTC. COWAN, RE. ROBERTA. SHAFER, RE. APPROVALS SEWER & WATER MAiN EXTENSIONS SEWER & WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOILTEST PERCOLATION TEST STRUCTURAL& MECHANICAL INSPECTIONS ON SITE WASTE'WATER DISPOSAL S~tSTEM DESIGN ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 REFERENCE: GENERAL: Lot 14, Roehl Subdivision October 30, 1998 The scope of this project includes the installation of a 1000 gallon septic tank and leachfield trench for the proposed two bedroom house to be located on the referenced property. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 17034 NORTH EAGLE RIVER LOOP ° surrE 204 * EAGLE RIVER, ALASKA 99577 Page 2 Lot 14, Roehl Subdivision October 30, 1998 Septic tanks installed with less than 4 fl. of cover shall be insulated. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed-up) before gravel (sewer rock) placement. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. Page 3 Lot 14, Roehl Subdivision October 30, 1998 MINIMUM MATERIAL SPECIFICATIONS: Any septic tank proposed for installation must be constructed by a Municipal approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron ASTM D3034 (PVC) ASTM F810 (aD?E) ASTM D2662 (ABS) Yes Yes Yes Yes Yes No Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical. Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. e When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements, which ever requirement applies. Page 4 Lot 14, Roehl Subdivision October 30, 1998 INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, eleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will take place on-site.. The inspecting'engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/INSTALLER