SKY RANCH ESTATES #1 BLK 5 LT 16
Onsite File Sky Ranch Estates #1 Block 5 Lot 16 #015-301-22 1974 seepage pit can only be tested for up to a 3 bedroom COSA approval. Municipality of Anchorage ,s On-Site Water and Wastewater Section • (907) 343-7904 ie ' ON-SITE WASTEWATER INSPECTION REPORT `. AUG 1 ZG2G Permit Number: OSP201138 PID Number: 015-301-22 Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑® Upgrade Name Westley Quinlan & Terri Jones ABSORPTION FIELD ❑® Deep Trench El Wide Trench El Bed El Mound Site Address 5500 Whispering Spruce Drive ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 0.6 GPD/SF 13.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4.0 Ft. Gravel depth beneath pipe 9.0 Ft. Subdivision Block Lot Sky Ranch Est 41 5 16 Fill added above original grade 0.0 Ft_ Gravel length 60 Ft. Township Range Section Gravel width 2.5 FL Beds: Number of Lines n/a Distance between lines n/a Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 1080 FF 1 n/a Ft. Well 100'+ 100'+ 25'+ TANK ❑e Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Greer Capacity 1250 Gal. Surface Water 1004 100'+ Material Number of compartments Lot Line 5'+ 5.0+/-* NA Plastic 2 Foundation 104 10'+ LIFT STATION Manufacturer Capacity Remarks * Waiver on File for 1.0' Gal. Alarm location Electrical installed by PIPE MATERIAL House to tank 3034 Tank to 3034 Installer drainfield A+ Home Services Drainfield 3034 co/MT 3034 Inspector Pannone Engineering BENCH MARK (Assumed elevation) 100.5 ft Inspectio v 7/28/20 7/28/20 Location and description 2,d 3'd 7/28/20 4"' 8/3/20 West side of House Bottom Trim ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date � of A�, ,k, � oe 49 TH Septic System-� FuApproved i-C�IiiC� (LW# Date- Steven N. .Pon CE 8149 �` Note: this approval does not include well permit requirements. )� j, /10FESSIrJW* kr V VJ/VL/ 101 90 51 m K n -0 ;u 0 CA K mom 0 K > M co M < < M m NJ Nj > < C) 0 m Om z 0 m x 0 m -u ox co 00 cn cn CD 41 C➢ ! --J 10 -P N) — --J > m ---1 -1 C'j 0 m Z (D POocovrn K: C� cf) K ---I 0m 41 4' m U1 rQ rQ M " O 00 M C14 N, " " —1-1-1 li 41 41 411 CA Un "i ;;0 :O mmm ;u --i cy) C n > (A -0 --1 Z 0 Cn �; ( 0 X 0 M> p -0 ;u 0 CA K mom M I M > F- r- x c K > M co M < < M m X cc) < N3 m m >x x cn > m > > M izz� c/) mM-1 0 c) m Om z 0 m x 0 m -u ox ;0 M c� u M M 00 0cn > CC) M 0 m w 0 -P' C➢ ! m � C) cn cl) -Tl M 0 ---1 m ---1 -1 C'j 0 m Z m M K: C� cf) K ---I 0m m 0 to O CIO I NOTES: RECORD DRAWING m r 5 In > z r, Z Ya X x M 0 M 0� z 7- �% A w W PANNONE ENG SVCLLC 1C.I. 1088) REVISIONS c P.O. BOX 1807 PALlUER, AK 9645 PHONE (907) 745-8200 FAX (907) 745-8201 SKY RANCH ESTATES #1 135 L16 DRAWN ACP WESTLEY QUINLAN & TERRI JONES 5500 WHISPERING SPRUCE DRIVE SITE PLAN ANCHORAGE, AK 99516 A49t .......... ' ot St— R. Pon— CE-8149 4p 21 TE/ 8 5/2020 ALE 1 " = 50' ,D. NO 15-301-22 RMIT NO. OSP201138 EET 2 OF 2 cl in rx m Om ox 00* C➢ ! m � 00 x 0 m r 5 In > z r, Z Ya X x M 0 M 0� z 7- �% A w W PANNONE ENG SVCLLC 1C.I. 1088) REVISIONS c P.O. BOX 1807 PALlUER, AK 9645 PHONE (907) 745-8200 FAX (907) 745-8201 SKY RANCH ESTATES #1 135 L16 DRAWN ACP WESTLEY QUINLAN & TERRI JONES 5500 WHISPERING SPRUCE DRIVE SITE PLAN ANCHORAGE, AK 99516 A49t .......... ' ot St— R. Pon— CE-8149 4p 21 TE/ 8 5/2020 ALE 1 " = 50' ,D. NO 15-301-22 RMIT NO. OSP201138 EET 2 OF 2 bvzbmzc�--i zAOAnooz �Am�moc�m n zo�z)„m,2 ozm N. N'AAt zomm�omz mpnooAu�A m mry..i?oo�„o �obzooz� aabm'izc�" 01 yi A 0 m=,azAncx boAoc�oym A r-OOZj � A� nao o�Zo ITOa n A'0 2 OzEO n c- :2: Z orb zm�� nr„ m v o Z I < A Z 0 omZ m mO m a o � ozmom n �v I'D A T z o moat m cmim�"< ron om-zio m bmZ� wn�x A Z w O wO ff rDAD wciOZ ,V -&ad ©p o 4a Og M 0 0 N 00. 00. 4L CTI CS% did 1� 1 Ut I 0� L� I a�-i 11 mZ � Cnoom� y c� m mo z m yz��zm O 'A m r y n K1 i y m bm cAon � y� � AA m2b � 'no V Aon � �0 11 aCc) mo c O < zE m wn�x A Z w O wO ff rDAD wciOZ ,V -&ad ©p o 4a Og M 0 0 N 00. 00. 4L CTI CS% did 1� 1 Ut I 0� L� I MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP201138 Work Type: Septic Upgrade Tax Code Number: 01530122000 Site Legal Address: SKY RANCH ESTATES #1 BLK 5 LT 16 G:2737 Site Mailing Address: 5500 WHISPERING SPRUCE DR, Anchorage Owner: QUINLAN WESTLEY T 50% & Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: m�0' itnieiit L.pa 6/9/2020 6/9/2021 13279 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Issued By: ZLI &eru Date: Date: t9 U—/) C) 0 Municipality of Anchorage P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 99519-6650 ® (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Department On -Site Water and Wastewater Section .tvcn� Department x x x x VARIANCE/WAIVER REVIEW x x x x Waiver#: OSV201022 COSA#: Permit#:OSP201138 PID#: 015-301-22 Legal Description: Sky Ranch Estates #1 Block 5 Lot 16 Engineer: Pannone Enqineerinq Services Applicant: Westley Quinlan & Terri Jones Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 1.0 feet. In addition, your request for a waiver of the required 18 feet horizontal separation between the existing and new absorption fields has been approved. The approved separation distance is 10 feet. See MP engineer's waiver request for justifications. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. M M M 0 N M 2 M , M M M M M M M 0 M M 0 0 M M M 0 M M 0 M 0 0 , 0 0 M M M U M U 0 0 M 0 M M N 2 M M M 0 M 0 M U 0 0 M M Waiver is Granted: X Waiver is not Granted: � ��? G r Date: Approved by: _ ,/L' ���K t �cJUZoJ Name of Reviewer ............................................... ■ ............................. ■ t **** VARIAN C E/WAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-301-22 Property owner(s) Westley Quinlan and Terri Jones Day phone Mailina address 5500 Whispering Spruce Drive, Anchorage, AK 99516 Site address 5500 Whispering Spruce Drive Legal description (Sub'd., Block & Lot) Sky Ranch Estates #1, Block 5, Lot 16 Legal description (Township, Range & Section) Lot Size 13,279 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ❑X Upgrade ® Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Field to Lot Line / Field to Field Distance:1110 I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 515 ! t4 /�% . Z� Waiver Fees: zt / 16,3 •-4 � Date of Payment: 5IA? l 249Z Date of Payment: Jul A 3196 A6 Receipt Number: G 15-1 L16 Receipt Number: Permit No.SP1;1611.3-2 Waiver No. C1 V a (> l Uaa Permit App__- : .....:c Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201138, Rebecca Carroll, 06/09/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201138, Rebecca Carroll, 06/09/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201138, Rebecca Carroll, 06/09/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201138, Rebecca Carroll, 06/09/20 Municipality of Anchorage Page 3. of 3 Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ct.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: Mo Permit 'rssued PID Number: 015-301-22 ,ama: Wastewater System: Tank Only Mike Gebhard Address: . 5500 Whispering Spruce Anch./ AK 99516 ABSORPTION FIELD Phone: Number of Bedrooms: Existing Trench 345-6231 Three (3) Soil Rating: 'rotal Depth from original grade: LEGAL DESCRIPTION GPO~t' Ft. Block: Lot: Subdivision: .,~ IDepth to pipe bottom from ~,6g,~al grade: Gravel depth beneath p~pe: 5 16 Skyranch Estate's',,! Ft. Ft. Township: Range: Section: Fill added above original grade: Gravel Length: Ft. Ft. Grave~ width: Number of hnes: J D~stance between hnes: Well: Exlst:ing Ft.I Ft. Classification (Private. A. B, C): Total Depth: Cased to: Total absoq:mon area: P~pe Material: , Ft. Ft. Ft' Driller: Date Drilled: Static Water Level: Installer: Date Installed: Ft. Newton Excavating 8 / 15 / 19 8 9 Yield: I Pump Set at: Casing t e, ght Above Ground: TAN K GPMI Ft. Fl. SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other: T.__"'~...~._ To Septic Absorption Lift Holding "ublic/Private Manufacturer; Tank Field Station Tank Sewer Line Anchorage Tank 1,000 I-rom ~ Malarial: Number of Compartments; we, >100' >100' N/A N/A >25' Steel Two (2) Su,facewatar >100' >100' N/A N/A ~ / LIFT STATION- NONE ON'LOT t0, une >5 ' >10 ' N/A N/A c~,. 'l-'ump on" level at; 'Pump o11" level at; I H~gh water alarm at; Founda,0n >5 ' >10 ' N/A N/A ,n. In.I In. Pump Make & Model Electrical Inspections pedormed by: Curtain Drain None Noted .er~,: BENCH MARK Septic Tank and Post Tank Cleanouts LOCabon an0 Ue$c~pbon: Placed Without a Permit. Garage Slab. Assumed Elevation: 100.0 Ft. Engineer's Stamp Inspections performed by: A. Harala Dates: 1st 1/3/04 ,~~ Department of Health and Human Services approval ,. ~,,:... Reviewed and approved by: Date: (~=v. ,o~) Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: None Issued Page 3 of 3 PID No. 015-301-22 /~103.2 · -, /('d / 1/1 11 / )7,6-~ I I ~--97,4 93,J N~'FEI sep-I:lc T(~nk (~nd Pos't Tc~nk Cle(~nou'l:s Drily ~/ere Pierced In November oF 1989 ~l'l;hou~: (~ Petrel't:. PROFILE AS-BUILT Scale: 1' = 10' ANDERSON ENGINEERING P.o.:Box'240773 ':. ~': i' i ~ANCHORAGE, AK99524": ~i · ~ 522-7773 ' 522-6779 (FAX ', · Janua~ 6,2004 Mr. Mike Gebhard 5500 Whispering Spruce Drive Anchorage, AK 99516 Subject: Lot 16, Block 5, Skyranch Estates Subdivision Well and Septic System Inspection, Testing and Certification Dear Mr. Gebhard: The septic system serving Lot 16, Block 5, Skyranch Estates Subdivision was originally constructed'in August of 1974. It was composed of a concrete septic tank with a capacity of 1,000 gallons and an absorption seepage pit approximately 30' in length by 16' average width with an effective depth of 9'. This information is taken from records found in the Municipal files and completed at the time of construction in 1974. The records further indicate the pit was constructed in soil materials composed of silty gravel and visually rated with an absorption capacity of 225 square feet per bedroom. The groundwater table was not found during construction of the system. A new 1,000- gallon steel septic tank was placed by Newton Excavation, Inc. in 1989. The tank was placed without a permit and no information concerning placement of the tank is available at the Municipal archives. An as-built of the tank has been der, eloped and is included for your review. Our initial probing of the monitor tube in the absorption pit indicated a water depth of 7.58'. We then injected 514 gallons of water into the septic tank and allowed it to flow into the absorption pit. After the injection the water level in the monitor tube was measured at 8.9'. Water was then allowed to settle in the trenches over night while the system remained in service and accepting effluent generated in the house. Measurements were taken in the monitor the next day and the water level had receded to the original elevation. Based on this evidenCe we conclude the system is capable of absorbing at least 450 gallons of water in a 24-hour period and currently meets Municipal requirements for certification. The absorption trench was constructed in 1974 and has served for more than 28 years. The average life of a septic system is normally around 10 years. This system is well past that age and may be nearing the end of its useful life. The effective depth of the pit is now 84% saturated. The remaining life of the system cannot be determined due Lot 16, Block 5, Skyranch Estates January 6, 2004 Page 2 of 2 to the many factors that influence the longevity of a system. Please note that no conclusions or guarantees as to the future useful life of this septic system are made or implied as a result of our testing and inspection. The well was allowed to run freely for 4 hours and the total volume of water was measured on a regular basis. The average flow over this period was found to be 3.62 gallons per minute. During this period the static water level dropped from 171' to approximately 175'. The well is in good condition and capable of producing a sufficient amount of water to meet requirements for Municipal certification. Samples of the water were tested for nitrate content, coliform and other bacteria. The results will be forwarded to you when they become available. Sincerely, Michael E. Anderson, P.E. Attachments Munic o ore Mark Begich, Mayo Development Services Department P,O. Box 196650 · 4700 Bragaw Street January 28, 2004 Anchorage, Alaska 99519-6650 (907) 343-8101 Office (907) 343-8125 Fax http://www,rnuni.org DEPARTMENT Michael E. & Kathryn E. Gebhard 5500 Whispering Spruce Drive Anchorage, Alaska 995016-2311 Dear Mr. and Mrs. Gebhard: Water Well Encroachment, Lot 16, Block 5, Sky Ranch Estates, Unit #1 Subdivision, Grid 2737 Right of Way Division has reviewed a request Mr. and Mrs. Gebhard for a letter of non-objection to an existing water well which encroaches three (3') feet into the ten (10') feet Utility Easement located on the northeastern side of the referenced lot. On the as-built survey dated 12/16/2003, submitted with the request, the petitioners have shown the existing water well. Right of Way Section issues this letter of non-objection with stipulations, and by using it the petitioner is agreeing to the following: 1. Municipality of Anchorage (MOA) will be held harmless, now and forever, for any damages or injury to any person as a result of the encroachments. 2. All applicable codes and regulations will be observed and maintained within the easement. 3. This letter of non-objection will in no way preclude MOA from full use and enjoyment of its rights within any portion of the easement. 4. Additional and extraordinary costs incurred during any future required construction, repair or reconstruction of MOA improvements to accommodate any or all of the encroachments shall be paid by the property owner. 5. Obtain letters of non-objection from the following utilities; Anchorage Water & Wastewater Utility, Chugach Electric Association, Inc., Alaska Communications Systems, Enstar Natural Gas Company, and GCI Cable of Alaska. All letters of non-objection should be retained in your permanent files. Should you have any questions, please call me at 343-8033. Sincerely, Jack L. Frost, Jr. Right of Way Supervisor ~~~Pr.operty Owne~ . Sky Ranch Estates Unit gl, Blk 5, Lot 16, Gebhard GR? TLR ANCHORAGE AREA Be' )UGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM MAILING ADDRESS ~-~-~. e/I 0' PHONE DISTANCE FROM WELl ~OI MANUFACTURER ~&.~*._'.¢/f' ~,Z~/~ MATERIAL NUMBER OF COMPARTMENTS INSIDE LENGTH ~ INSIDE WIDTH ~ LIQUID DEPTH LIQUID CAPACITY /0o0 GALLONS, SEEPAGE PIT: NUMBER OF PITS DIAMETER LINING MATERIAL /~¢'~ff~¢~' -~ BUILDING FOUNDATIOI~ CRIB SIZE: NEAREST LOT LINE__ ORWIDTH/~,~22 LENGTHg, DEPTH q' DIAMETER-- DEPTH DISTANCE FROM: WELL I TOTAL EFFECTIVE -~O ABSORPTION AREA (WALL AREA) ~(~ z/' SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE BUILDING FOUNDATION CESSPOOL APPROVED CONSTRUCTION g "~¢¢~ ¢'~i NEAREST NEAREST LOT LINE SEWER LINE DEPTH DISTANCE FROM: SEPTIC SEEPAGE TANK __ SYSTEM OTHER SOURCES DISAPPROVED REMARKS DISTANCES: INSTALLED BY: PIPE MATERIAL: LOT SLOPE: REMARKS: '~/~ Form No. FO-031 DIAGRAM OF SYSTEM DATE~*'¢I, 33, 797.4/ APPROVED G.A.A.B. NAME OF APPLICANT GREATER ANCHORAGE AREA BOROUGH SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PEP, MIT _ _ MA,L,.~ *DD.ES. ~;4Y] '- ?/ PERMIT NO. PHONE SEPTIC T^NK, ~-~ , SeePAGE ~IT ALSO CONSIDER AREA WELLS. /~-*)~") ) DRAIN FIELD __~/~:'2 / GRAVEL BACKFILL CONFORM TO E~OROUGH REGULATIONS REGARDING INSTALLATION. OR (;REAT~R AItCHO~Aqr ,~ G~ HEALTH D~P.r.~,.~T 327 EAGLE STREET A~CHORAGE~ ALASKA' 99501 CASE Feet S o,i,1 Ch~a.~act eristics Was Ground Water Encountered?._._k,l~ If Yes, At ,/,.at Depth Reading Date Gross Time ¢rcoLal:i~h-l ate' I"/' )~'ihu--~---- L_ Location Sketch Net Drop F~cDosed * . 2nstallatuon: S~,eDa~a Pi~ %/ Drain Field Depth Of Inlet_ Do. pth TO ~o"ttom' O'~ ~it Or Tl'enc~ Test Performed By:__~ Date: MUNICIPAUTY OF ANCHORAGE Development Services Departments Phone: 907-343-7904 On -Site Water & Wastewater Section "J Fax:: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 015-301-22 1. GENERAL INFORMATION Complete legal description Sky Ranch Estates #1 Location (site address) 5500 Whispering Spruce Current property owner(s) Mailing address Real estate agent Westly Quinlan 2. TYPE OF DWELLING: Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 Expiration Date: Day phone Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well El Private Septic FE Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ requestWaiver . + i Distance: Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. Date: 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal' affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of .this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Reliance on this report by another person is at their own risk. Pannone Engineering Services LLC highly recommends buyers hire their own engineer to evaluate this report. Name of Firm Pannone Engineering Services Phone (907) 745-8200 Address P.O. Box 1807 Palmer, AK 99645 Engineer's Printed Name Steven R. Pannone P.E. 6. DSD SIGNATURE Date ZG® (:�p of 4 .� 49 T 0 ... � .'rte...... J ` . \�_'� System #1 Approved for ` bedrooms A Steven Pannone System #2 Approved for bedrooms n,r C� ,� .y Disapproved ''�n'"1A r�5```' 4 Conditional approval for bedrooms, with the following stipulations: TY (OP(A, .tri. ON-SITE WATER AND WASTEVVATER z^ IJKUUKAM_O-Z', �J Q R ,J J F�SERV�G�� �,,\\• By: ClJn �y.� ���i Original inal Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based -only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet r_ COSA Checklist Legal Description: Sky Ranch Estates #1 B5 L16 Parcel ID: 015-301-22 If more than 1 septic system on lot: COSA Checklist # 1 of 1 Structure served by this system 1 A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled Total depth 198 ft Cased to 198 ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) >: -' in. Date of flow test for COSA 6'°11M Static water level at beginning of test 177.5 ft. Comments B. TANK DATA Age of tank(s) New years Tank type/material Measured operating fluid level in septic tank NA ❑ Standpipes/foundation cleanout per record drawing Date of pumping NEW D. ABSORPTION FIELD DATA Deep Trench Which system tested (date installed) 7/2$'20 ❑ ALL standpipes present per record drawing Total measured depth from grade 13 ft (max) Measured depth to pipe invert from grade 4 ft (min) ❑ NIA — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective Well production at time of test 3.04 Qpm Water storage tank volume NIA gallons Well disinfected for coliform test? ❑ Yes M No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by PES Date of Sample GM,20z+ C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date New Results E✓ Pass For 4 bedrooms Fluid depth prior to test in Water added gal New depth in Elapsed time min ❑ Code -required soil cover over field Final fluid depth in ❑ System presoaked Absorption rate gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) _ date of test) If yes, enter date Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' frYes Community Sewer Manhole/Cleanout > 100' [7f Yes if No ft M Yes if No ft Neighboring Tank > 100' ('Yes if No ft Private Sewer/Septic Line > 25' Yes if No ft Absorption Field on Lot > 100' JWes if No q9 ft Holding Tank > 100' Yes if No ft Neighboring Absorption Fields > 100' Private Wells > 100' Animal Containment > 50' (Yes if No ft Yes if No ft ft Community Wells > 200' Yes if No ft Water Service Line > 10' Manure/Animal Excreta Storage > 1.00' if No Community Sewer Main > 75' ®Yes if No ft Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' frYes if No ft Surface Water > 100' ERYes if No ft Property Line > 5' es if No ft Wells on Adjacent Lots: Private Wells > 100' Yes if No ft Absorption Field > 5' Q.Yes, if No ft Private Wells > 100' [Yes if No ft Water Main > 10' Yes if No ft Community Wells > 200' Yes if No ft Water Service Line > 10' 21yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' HYes if No ft If absorption field is under driveway comment below Property Line > 10' ❑ Yes if No ft Wells on Adjacent Lots: Water Main > 10' Yes if No ft Private Wells > 100' Yes if No ft Water Service Line > 10' Pi Yes if No ft Community Wells > 200' Yes if No ft Surface Water > 100' Yes if No ft F. ENGINEER'S COMMENTS �Af 1 lqv-f l 6N a �z G. ENGINEER'S CERTIFICATION l certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. 7:��b COSA Checklist yellow sheet of A�q *� �9 TH Steven R. Pannone . CE 8149, F Municipality of Anchorage P.O. Box 196650 O 4700 Elmore Road Anchorage, Alaska 99519-6650 ® (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Department On -Site Water and Wastewater Section �»cnr >o Sf n .n c t�v�N 11ep a r nuieRt * * * x VARIANCE/WAIVER REVIEW * * * * _ _ Waiver#:_ OSV211038 _ _COSA#: OSC211321 Permit#:_ PID#: 015-301-22 Legal Description: Sky Ranch Estates #1 Block 5 Lot 16 Engineer: Pannone Engineering Services Applicant: Westley Quinlan Your request for a waiver of the required 100 feet horizontal separation from the absorption field to the private well has been approved. The approved separation distance is 95.0 feet. See engineer's waiver request for justifications. This waiver approval applies to the existing absorption field only. Any fixture upgrade to the on- site wastewater disposal system will require all separation distances be met or another approval from this department. ■ t .. t t\■ .................. 0 0 0 M M N ...... t ....... U ............ \ .. t t t ........... ■ 1 Waiver is Granted: X Waiver is not Granted: Date: % 11,20 0 1 Approved by: Ut6c,,, aluzj�_ F Name of Reviewer ......................................... a 0 N 0 X N ...... t ....... t t .......... IN .. ■ 1 **** VARIANCE/WAIVER REVIEW **** A.7�, r; • 'a- r • r !jai. s. s: Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road P. O. Box 196650 Anchorage, Alaska 99519 Subject: Sky Ranch Estates #1 B5 L16 Well to Drain Field Waiver Request We would like to request a waiver for separation distance for the drain field to the well located on the subject property. The existing drain field was installed in 1974 and is a seepage pit type drain field with the following dimensions 30LF x 18'wide x 9'effective, the well was also drilled in 1974. Based on the latest survey along with information gathered in the field during investigations as well as the installation of an upgraded drain field we believe the existing drain field encroaches on the 100' protective radius of the well. We are requesting a waiver to AMC 15.65.210.B.1.b to a distance of 95'. The following summary of the property characteristics listed below justify the variance to the above-mentioned code. Skv Ranch Estates B5 L16 Drain Field to Well: Distance from sewer system bottom to groundwater 7.34 Soil sorption below sewage system 4.09 Soil permeability below the system 1.87 Water table gradient 2.9 Horizontal separation 2.92 Total Points 19.12 The sum of the above values could equate to the following conditions: "Almost sure to be free from any form of contamination from household sewage." This waiver request meets the above criteria for approval and does not constitute a risk to health. I hope the above information will assist you in determining that the waiver should be granted. Mailing: P.O. Box =.507 Palmer, AK 99645 l ui ?i C t=: }!' 745 8'00 FAX: (��a07 745 820" Page 2 of 2 If you have any questions or concerns, please contact me at 272-8218. Steven R. Pannone OE 4t Steven R. Pannone,P.E. Ovvner/[ivi|Engineer Mailing- P.[),Box 1DD7Palmer, AK99545 / Te1ephon�-��D7}745S2OO FAX: (907'7453ZOl Municipality of Anchorage.,i:: Development Services Departmefit Building Safety Division ' On-Site Water and Wastewater Program% " 4700 South Bragaw St. ~,~,-t~,,,' ' p.O'. Box 196650 Anchorage, AK 99519-6650 www. ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF }~'- ~,' ""' ' ,,-,-,t_, ,-, AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING o =% Parcel I.D. 015-301.22 1. GENERAL. INFORMATION HAA# Expiration Date: __4~/Z ~/O,~[ Coml~lete legal description ' Lot t6, Block 5, Slq/ranch Estates Subdivision Location (site address or'~irections) ~5500 Whisperin,q Spruce Drive e · Current Prope.rty owner(s) _Mike Gebhard Mailing address Lending agency Day phone 345.6231 5500 Whlsperincl Spruce Di'ive Anch°raqe, AK 99516 Mailing address Real Estate Agent' Mailing Address ,.. '.' '", '?.. '~ :7,, Unless therwg§e requested, HAA will be held by DSD for pickup. " . Three {3) Day phone NUMBERfbF'BEDRooMs: TYPE OF WATER. SUPiSLy: Individual Well Individual v~ater.Storage; Community Class. Well Public Water System Day phone TYPE OF WASTEWATER DISPOSAL: [~ Indivi'dual On-site [~ . [] " Individual Holding tank [] [] Community On-site ~ · [] Public Sewer '[] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates ol; Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for propedies served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for propedies served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for.a period of up tO one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errurs or omissions in the professional engineer's work. 1 " Mu iCip lity fAn hor I' ' :Dep rtment n a o c age ',i ' DeveloPm nt . Services a , .' ~ ~ ' ~ 'B~ilding Safety DMSiOn '. ~': ~.' omsite.,,water & Wastewaier Program . ': : ,: : ~ . . . : ~ '. ~ .:.4700 South Braga~ st. ~,' = ~=" . . ~ ' : : ; ~ .~ :~ (907)343-7904 = : =HEALTH, AU OR,T APPROVAL'CHECKDST . ~ ,,' kggalDescription:T. Lot~6, BloCkS.S~ran~h.EstatesSubdivlsiO~ ~. ~ ~ WELL DATA: '.; ~ ',~ Well type ~}ivat°' : ' ' : I~A,~B,°ropr°wde~wslD~[ ~ ~ .: LO_".WN. ~" ':~'~ Date completed Sl, f197, · '~,,;,,,,~ ~ , , , '; ',~': .~ ~:..~: ~. ~.: ...' ~ ~ "~Sanita~'~eal ~/N)~ ~: ~ ~ ~ :W~res properly protected (WN) Y " ,, ~ .... Casing height (abo~e ground)' ,.: .... . 'i::',:, , ,.,.: ~ . ~ ' ' ~ . FROM WELL'.LOG' ~ ' ;' :,'~': ~ Da~eoftest~: ': ::: - 3/23fl984 ',~-~-. :.. " , : Well producton - ' 58 ' ' ' ~ nm '- :::'~ , . , · -- ~ ..... - ~.~ ....... : , .... ~ a.u" ..... " 'oPm:" :.: . : WATER SAMPLE RESULTS' ~ ' ::.::,, :. :: ;,.;';:',' .. : , '. :~ ~ ~' , ~: ::' · , Codorm 0.,colones/100ml ~ Nttrate' 10-m-n,' ~ ...... ~.~ ~. ,. .... . . ,,.. . .., . , . - · ~,,.. . :': - umer oac[er a u Colon es/100 mi ~-:' '~ Dat~.ofsample: ,~12003 . i~.: .~C01~ct6dbv: ~'A H~ra'l~ ':' : ' : : ~', . . : ~ . :: :.:~', ' · ~ I~ ;,, : .[:~ , .: , . ,.. ; :'; ~ " ,- ". ~.'~" ~; SEPTIC/HOEDING'TANKDATA ~ ,, ~ : ~ ~,,,:' '~ ~ :;: ~ I~ Tank T~e/Matenal Sept c/Steel ' ~ .... ~ ' ,.,.,: ' , . ~ ,' ", :' ": = .:;" ";':uaminstaed~ll~511989,~,'; , . '. ,. , ,, ~ . : ?.: ~ . , .... : :~,, ,, .... ~ ,~'; .... T V." ~' ':~'~,O00,:.'':'gal : "' .'. ~, ~ .~ _ - . _' .... ~ "'~ · '." .: "..' ~'.' :: ..... ' J;'~;'.-' '.~; ,':' ~ . .. ~ i-an.,~ ~~ze' .... ,~umuer,o~ ~ompa~ments z ~: 'F°~at'°n.~n?u~,(Y/~)Z, _ ,Depr~s'~n over ta~ (Y/N) ~ :Hgh wht~r ~'Ia~i(Y/~)'!N' :. ~.; ~ : , : , ,. ~ '~ , . ¢ , , * , ~, .... ~ ,. per Denah Punmlno , · - , ateefpumpng ~1612004: , , r.Pum ..... , - ' ' ~ :!C.~' ABSORPTION FIELD DATA . ~ ~ :,':~ ' ': ' ' ..... '~' .;' :: ' ~: i ' r, .,, ~,. ~ , ~Da~,!nstalle~ 81111974 .; Ir : So~I rffhng ~(g.p.d./ft or ft%drm) 225 SFIgdrm sYstem'~D6 se~a~oe"Pit ' ,Lent '3 , .............. ] . ~ '1 ". ~' .... : :l . ,'., . ' . ...... Gravelbeowppe.9 - '. ' 'ft ~" '' ~'~ ":T ~I~ ~-4~1- ,r' '~ L --. ------.--' ~' . ' ~ '~ i~ ..... : '. __,~ ].t, ' i, ::. , ' :' ~'. ii ~ jo,~e~,..~.,.: . ~: ~mausorpuonarea~u4tt= . .. MonitorinotubeY :, r .... ; . ~ 'l ~ ~ ~ " , : ..... ~, .,., ] [Date of adequacy test 12/512003 ~, ~; i , ~ ~e~-.*:/D***/~-.~' ;,~; i~ ~u~o '°epm in absorption fie d before te~t 91ih ' ~ ,~ ' [;:= W'at'er"add~5~-,: , .,?: ~ , ., . ;~ . , , ~', , , ~...t f ~ ; · ,,: ~' ~' :, ',~ :'~ - ~ . : ~, I ~ '['~' - ;I ,',, ~, :!'= ~ : = , · ' ~'~'~. ' ,',~' Anyrejuvenatontreatmentfnast12mo~/~.,+.~x~',~, : ....' :' ~: ' :,' .I ' ,.. ~',' .,~ .... : .... , ~ .... '" , 'LL',t?~,'z~/,'" : '" ~ ~..~. ryes, gveeate,' ' : : I , , I. , . ,' ,., . ' ,l ,', , . , ', , ........ , , . , , ,: , , .... ' "' ' ' ' ' ' ' '" ' ~'" ~ ' '"'~ ' ' : ' ' ' 'i' " ' ' ' . . := ; . ,,,. ; . . . ~ .' , :~ , , '. SGS Ref.# Client Name Project Name/// Client Sample ID Matrix 1037817001 Anderson Engineering Lt 16, Bk 3, Skyranch Est. S/D Lt 16, Bk 3, Skyranch Est. S/D Drinking Water Sample Remarks: All Dates/Times are Alaska Standard Time Printed Date/Time 12/11/2003 12:44 Collected Date/Time 12/07/2003 16:10 Received Date/Time 12/08/2003 16:58 Parameter Results PQL Units Method Allowable Prep Analysis Container ID Limits Date Date Init Waters Department Nitrate-N 0.100 U 0.100 mg/L EPA 300.0 B (<= 10) 12/08/03 JJB Microbiology Laboratory Total Coliform col/100mL SMI8 9222B A (<=1) 12/08/03 DKC :DEC:--29--0~ lION 11 .'11 HOLT LAI,19 SURVEY MUNICIPALITY OF ANCHOP~GE DIVISION OF ENVIRONMENTAL HEALTH DEPARTMENT OF HEALTH AND ENVIRONME~NTAL PROI~CTION APPLICATION 5~DR HEALTH AUTHORITY APPROVAL CE~rlFICATE 1. General Information Application Data ~~ (a) Legal. Descript~O~ (in~lu.d~_. 19%, block,, subdivisioO, section, tcwnship, range) Loc~akion /address o~ di~ecticns) is (cheek one) Lending Institution [_~; C~aer/buil~er r-~.' (c) Applicant Buyer [---~; Other ~---I (explain), Address Address Telephone 2. _Type of t~sidence Single-Family ~. Multi-Family ~--] Number of Bedrooms_ ~ 3. Water sup. p_~ Other (descrihe) Individual We llj~ terra, unity ~[ Public ~ Note: If community vmll system, must have w_~itten confirmation from the State Department of Environmental Conservation attesting to the legality and status. Is the well adequate for the number of bedrooms specified in this HkA 4. Sewage Disp_gs__a_l Is the wastewater disposal system adequate fcc the hunt,er of L~Jdrcc~ns ~?N) [Page 1 of 2] 2-15-84 5. Engineering Firm Providin~_~s.k~qtions, Tests, Data and Information Adduess Signed by I certify that I have. checked, verified, or conformed to all MOA HAA Guidelir~.-.s ii effect on the date of this inspe, ction. ( ENGINEER SEAL) 6. DHEP .~proval Approved fo~ ~ kedr ccas [}ate Approved ~ Disapproved ~ Conditional Ter~ of Conditional Approval __ The~Municipality of Anchorage Department of H~;alth ard Envircnn~ntal Protection d, not guarantee the c>ontinued satisfactory perforr~nce of the wate~ supply and/or tl wastewate~ disposal system. This approval indicates that, as of the va].idatiop, c~ shcwr~ above., based oo the data and information furnished by an er:gi~er registere. the State of Alaska, the water supply and wastewater disposal system is safe and tional fGt' the number of hedrocm~ and type of structure indicated. (DHEP SEAL) 7. Mail the HAA to the following add~ess: KB2/d5/s [Page 2 of 2] 2~].5-84 MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) MUNICIPAIll¥:OF ~NCHOP~GE DEPT, OF HEAL'i'H & CHECKLIST - FEBRUARY 1984 ENVIRONMENTAL PRO]:ECTIOI~ MAR 2 ? gsr-!. , W~ll Log P~esent ~N) ~6 iF3 Dats Cc~pleted .5~//~/,/Y~' Total Depth /~/ Cased to /~ /, Depth of Grouting Static Water L~i /'.r/~-_~ / Pump Set At Casing He ight Abo~ G~ound / z Sanitary Seal on Casing ~/N) Electrical Wiring in Conduit~N) DepFessi~n A~ound Wellhead ( ~./3 Separation Distances f~ Well: To Septic/HoldinG Tank cn Lot ~' ,; 0~' Adjoini~g Lots //Qd ~- To Nearest Edge of Absorption Field on Lot /~)/ ~-; On Adjoining Lots To Nearest Public Sewe~ Line ~/,~ To Nearest Public Sewer Cleanout/Manhole ~J//~ To Nearest Sew~ Service Line on Lot B. S,.'P,'IC/HOLDING TANK DATA Standpipes ~/N) ! Depression over Tank Sim~ /6~6~ Ai~-tight Caps ~N) "Date Last Pumped No. of Cut~a~tm~nts / Foundation Cleanout ~N) Pumping/Maintenance Cont.'act, or~ File (Y/N) /~t~ ; fo~ Holding Tank' High-Wate~ Alarm (Y/N) /~,/~z Tempora-~Y Holding Tank Permit (Y/N)/~//~, ,, Se .p~ation Distances f~cm Septic/Holding Tank: To Water-Supply Wall To P~operty Line To Water Main/Service Line TO Building Foundation To Disposal Field c~-~/J? TO Stream, Pond, Lake, c~ Major D~a.inage C~nts [Page 1 of 2] 2-15-84 ALASKA e dlRO lmellTAL CO[1TROL SekulCe$, IFIL GREG PEMBERTON 5500 WHISPERING SPRUCE DRIVE ANCHORAGE AK 99516 SELLER - GREG PEMBERTON BUYER - SUBDIVISION - SKYRANCH ESTATES #1 BLOCK - 5 LOT - 16 ADEQUACY TEST FOR SEWER SYSTEM THE TYPE OF ABSORPTION SYSTEM IS A SEEPAGE PIT WITH AN AREA OF 864 SQFT. %~{E SYSTEM IS CAPABLE OF ACCEPTING 450 GALLONS OF WATER PER DAY. THE SURGE CAPACITY OF THE SYSTEM IS 900 GALLONS. BASED UPON THE TEST DATA THE SYSTEM IS ACCEPTABLE FOR A 3 BEDROOM HOME. THE SEPTIC TANK WAS PUMPED ON MARCH 22 1984 . : FLOW TEST ON WELL THE WELL FLOW RATE WAS 5.8 GPM FOR 3 HOURS. SEPTIC TANK ADEQUACY THE EXISTING SEPTIC TANK VOLUME OF I000 IS ~H)EQUATE FOR THIS 3 BEDROOM HOUSE. 1200 LJJesl 33rrJ Auenue, $ui1¢ B' finchoraq¢, AI~skQ 99503 "(907) 561-5040 ENVIRONMENTAL PROTECTION DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION 825 L Street - Anchorage, Alaska 99501 NOV 6 1979 ENVIRONMENTAL ENGINEERING DIVISION · Telephone 2~4'4720 RECEIvJ~b MUNICIPALITY OF ANCHORAGE REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1. Incomplete ~equests will not be processed. Please allow ten (10) days for processing. Marianne and John Scott ~y~LiY.~ ~ 349-2610 MAILING ADDRESS /~. ? SRA Box 1633-T, AnchoraAae, k 99507 PROPERTY RESIDENT (if different from above) PHONE Same 2. BUYER PHONE Gregory Pember ton 243-0399 MAILING ADDRESS 7055 Crawford. Anchorage. Ak 99502 S. LENDING INSTITUTION ,g~uri~v P~riFi~ MAILING ADD~ESS 1011 E T~lder Rd~ Anr. hnrn_~n. Ak gg~03 4. REALTOR/AGENT Jack White Co~ c/o Bonnie Mehner, MAILING ADDRESS o~?~)'j ~, ,S~rPP, h~ Anr, hnrmsp. Ak' ggsc)3 PHONE ~76-1933 PHONE 277-1553 5. LEGAL DESCRIPTION Lot 16, blk 5, Sky Ranch Estates STREET LOCATION NHN Whtsperin~ Spruce 6. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] One [] Four [] SINGLE FAMILY [] Two [] Five [] MULTIPLE FAMILY ~ Three [] Six [] Other 7. WATER SUPPLY [] INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled [] COMMUNITY since June 1975, For wells drilled prior to that date, give well [] PUBLIC UTI LITY depth (attach log if available.) 8, SEWAGE DISPOSAL SYSTEM ~2] INDIVIDUAL/ON-SITE** **If individual/on-site, give installation date A.g ?% lc~74 If system is over two (2) years old an adequacy test is required [] PUBLIC UTILITY by this Department, NOTE', THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED, THIS SIDE FOR OFFICIAL USE ONLY DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME -- DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS ~ SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [~] TWO [] FOUR [] SiX PERMIT NUMBER 2. WATER SUPPLY "-{~] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3, SEWAGE DISPOSAL SYSTEM PERMIT NUMBER ~ I NDIVI DUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER ~Septic Tank or []Holding Tank---- --- (~,~,/ ~,,-~.,-~-~ Size: I ,L-~ If Tank is homemade SOILS RATING give dimensions: ~..~ ~ ~.~-~ TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4, DISTANCESwELL TO: Septic/Holding(~)~ Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line ~¢-~_ 5. COMMENTS ~PPROVED FOR ~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED DATE BY (Title) LEGAL DESCRIPTION 72-010 (Rev. 3/78) ~:LA~S MUNiCIpALITY OF ANCHORAGE .... DEPT' OF HEALTH & November 13, 1979 R&M No. 95~I~ONMENTAL pROTECTION Mr. Scott c/o Jack White Realty 3201 C. Street Anchorage, Alaska 99503 t 6 1979 RECEIVED Attention: Bonney Mahnar Re: Adequacy Test on Existing Sanitary Sewer System; Lot ~, Block 5, Skyranch Estates No. 1, Anchorage, Alaska. Dear Mr. Scott: Per your agents request~ we conducted a test of the sanitary sewer system on the above described property. The septic tank was pumped prior to the performance of the test on the seepage pit. During the test, the liquid level was measured before and after the addition of 1,000 gallons of water. All liquid levels were measured below the top of the standpipe and are shown in the following table: Initial Water Second 24 Hour Total Reading Added (Gallons) Reading Reading Drop 10.8 1,000 9.3 11.9 2.6 The water level rose 18.0 inches with the addition of ],000 gallons of water indicating a capacity of 55.6 gallons per inch. Twenty-four hours later, the liquid level was again measured and found to be at 11.9 feet. It had dropped 2.6 feet, or 31.2 inches. This indicates an average effluent acceptance rate of 1,735 gallons per day for the surrounding soils. If the four bedroom residence on the property is to house eight people, the average load on the system can be expected to be 600 gallons per day. We can therefore conclude that the system is disposing of effluent at an adequate rate for a four bedroom residence. We appreciate this opportunity to be of service to you. Please contact us if you have any questions regarding this letter or if we can be of additional service to you. Very truly yours, R&M CONSULTANTS, INC. Michael C. Hartley / Geotechnical Engine~/~ NCH/dj/ATSI-B January ?..I, lg75 3ltl East !'~'orthern Lights Blvd. ~.~mhorage, Alaska 99503 Pat ,lomas Lot lO, Block 5, Sky Rancl) Estates Fhl,~ office has inspected th~. ~ie'Jl casing and taken another ~ater smnple at the subject locatio.. The ~'ell is nroperly sealed and tBe sample ~attsfactory. This ~fflce is nov~ able to qive ses?er and water a~proval for t. he dv~elltng, If you have a~y questions, p~}a.~e feel free to contact me at 274~4561, mxtenston 136. Sincerely, Sanl !:arian cc: . and Hrs. John C, Scott January 6, 1975 Alaska stat/~ar~ 310 l'~st Norther] Lights Blvd. ~not~, AI~ 99503 AttentJ.~: Pat J~nes 16, Block 5, Sky ~.~eh Estates #1 'Ibis letter /s to inf(~ml you ~lat the previous sewer and water approval on ~he subject loc. has been wl~wlrawn. Th/s act/on is ]wing ~ken followl~3 probl~ wit~l th~ well. cont/n%~ its disapproval. m.- soo~ a~ the probl~a le torte=ted, ~ will ~ke ano~r take a water s~t%31e. Tr~ samplo should L~3 taken ~.io~ to water. If you hav~ any questions, please feel fz~e to conta~ m~ at 274-4S61, Silly, Susan t~,. Dlak~r~on, Sanitarian SED/ko cc: Mr. and Mrs. J~n C. Scott Certified No. 740420 SENDER: Be sure to follow ;.sfrueflons on Other slde I'' [] Show to whord, where delivered: PLEASE FURNISH S~RVICE(S) INDICATED BY CHECKED BLOCK(S) [~ Deliver ONLY /: to addressee Ranch Est.~e;ved tAe 740420 ko ,~SUREe ~0 1/6/75 -' :~ ':; ::~ ~'' DATE DELIVERED - ,elow R~:CEIPT FOR CF. RTIFIED MAIL--30~~ (plus postage) '~5-0~ .... POSTMR"K · STREET ~ND NO. OR DATE P,O,, STATE AND ZIP CODE flZZU~D--~ q: Shows'fo whom an~o de~red ......... ~LI~ TO ~ODRES~[[ O~[Y ,.....;.~ ................ :.-....:-.~ ........... 50~ SPE~'LAL DELIVE~xIr~eo roquired) .................................... PS Form [~0 INSURANCE COVERAGE PflOVIDEO-- ~p~. m?~ 3800 IIOT FO~ INYERHATIOHAL UAIL GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 Date Received Time of Inspection Date of Inspection t. Approval Mailing Address: 2. Property Owner: Mailing Address: 4. 5. 6. REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR Legal Description: Location: Well Data: A. Type ~ C. Construction r:p,/,[:-~ Sewage Disposal System: No. of bedrooms B. Depth (/ G~ D. Bacterial Analysis D. Seepage Pit: A. Installed ~/~$/7~z B. Installer C'7~-/~.~. ~ C. Septic Tank: 1. Size /~o~ . 2. Manufacturer . 1. Absorption Area ~'~'~/2. Material E. Disposal Field: Total length of lines Distances: A. Well to: Septic tank Nearest lot line ~ , Absorption area , Other contamination /ool ., Sewer Lines __ B. Foundation to septic tank , Absorption area C. Absorption area to nearest lot line EQ-034 (1/74) Page 1 of two pages .Page 2 of two page~ - R(~'~':st for Approval of Individual /~er & Water Facilities "Legal:, Description Comments ,~/~z,~,~., Disapproved ~, Date ApProved z~c~. ~ i, ApProval,Valid for one year from date signed Greater Anchorage Ar~a Borough, Department of E6vironmental quality DIAGRAM OF SYSTEM I certify that the information contained in this request~ for approval to be a ,true and accurate representationlof the subject sewer and water :acilities and these facilities are operating sati sfactorl ly. SIGNED i Date ' . EQ-034 (1/74) :.~, 3330 December 4, 1974 GREATER ANCHORAGE ARi~.I, BOROUGH Department of Environmental Quality "C" St., Anchorage, Alaska 99503 274-4561 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES 1. Type of Inspection: CMRO VA FHA CONV xxxx 2. Property Owner: _.FNeJAnetb,_J. Mailing Address: ~ ~i~_~~ Day'ho.ne 3_7.6-5~54 3. Name of Buyer: _~~o~~~ Mailing Address: C/o 4. Name of Lending Institution: Mailing Address: _~_rthe~B__~j_~'ghts Name of Realtor or Agent: Mailing Address: Phone 279-7637 ext 37 Phone 6. Legal Description: __go~_l~Block 5, Sk% Ranch Es~es~£ Location: 7. Type of Facility to be inspected: ~amil~ No. Bdrms. 3 8. Water Supply Type of Supply: Public Utility Individual x×× If Individual, number of dwellings presently served A~A~ix~ appraisal states private well If Individual, depth o'? well unknown Sewage Disposal System Type ,o'? S~stem: Public Utility Individual (on-site) ×x× If Individual, date of installation _ approx ap~il o~ 74