Loading...
HomeMy WebLinkAboutAUTUMN RIDGE LT 28Autu n Ridge Lot 28 #015-054-31 ' Municipality of Anchorage Page Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street P,O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 'ON-SITE WASTEWATER DISPOSAL SYSTEM ANDIOR WELL INSPECTION REPORT Permit Number: SW030138 PID Number: 015-054-31 tame: - Wastewater System: New Crown Pointe, Inc. Address: P.O. Box 112313 Anch., AK 99511 ABSORPTION FIELD Phone: Number of Bedrooms: 5' Wide Trench 345-6277 Five (5) Sod Rating: Total Depth from onginal grade: LEGAL DESCRIPTION 1.2 Block: Lot: Subdivision: Depth to ~pe bottom from original grade: Gravel depth beneath p~pe: 28 Autumn Ridge 2 Township: Range: Section: Fill added above o~ginal grade: Gravei Length: 2 Gravel w~dth: Number of lines: ~ D~stance between trees: Well: New 5 Ft. 1[ .t. Classification (Private. A, B, C): Total Depth: Cased to: Total absorption erea: P~pe Material: Private 44 F~. 44 FI. 640 ,~' ASTM 3034 PVC Driller:. Date Ddlled: Static Water Level: Installer: Date installed; Alpine Drillin!] 5/1103 26 ,t. Sanders and Sanders 61312003 ~e,d: 30 GP~, IPump Set at:FI. Icasingl'eightAb°veGr°und:>2"'. TANK SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other: "'~_ To Septic Absorption Lift Holding ~ublic/PfivateManufacturer; ~apac~ty From ~ Tank Field Station Tank Sewer Line Anchorage Tank 1,500 Matenah Number of Compartments: w~, >100' >100' NIA N/A >25' Steel Two (2) Sur~aceWater >100' >100' NIA N/A ~ / LIFT STATION - NONE ON LOT Lot une >5' >10' N/A NIA O' N/A N/A In. in.I In. Foundation Cu,~,n Dra~n None Noted Pu~ ~e & ~ede, ~,e~,nca, ,nspa~ons,e,or~d ~: reme~s: BENCH MARK Garage Slab 100.0 ~t. Engineer's Stamp .......... ~cv:... Inspections performed by: A Harala Dates: 1s~ 613/03 2nd 6/3/03 ['~t.'"~;;';;'~E'~ Department of Health and Human Services approval Reviewed and approved by: /~/..-//~-~ ~/O-e~ Date:~ '~' ge DEVEOPMENT SERVICES DEPARTMENT 4700 South Bra le, )-6655 - 343-7904 On-Site Disposal Inspection Report Permit Number: SW0301~ Page 2 of 3 PID No. 015-054-31 ABBO1-F ROAD 1 / / / ./ PLAN / / / / / / / / / ( s2 Site S2 AS-BUILT SCALE 1' = 40' z N 89'59'00"E 75.00' ® WELL DRIVEWAY ESMT. (BK 463, PG 254) Five Bedroom Home I A B S1 28.2 110'0 S2 29.6 120'0 C4 17.0 ~44.0 1,41 55.1 J39.8 C5 64,1 J45.2 N 89'53'31"E 87.90' BUFFER E ESMT. LANDSCAPE ESMT. LOT 28, AUTUMN RIDGE Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK, 99519-6655 - 343-7904 On-site Wastewater Disposal System or Well Inspection Report Permit Number: SW030138 Page 3 of 3 PID No. 015-054-31 96,9 ............ Geo._~.ex_.~![e F._(~brl__c. __. I)r~InFletd Rock ~---BS,0 64' Trench Length (NTS) PROFILE AS-BUILT Scole: 1" = 10' INE DRILLING FRX NO. : 907 345 0202 Jan. 26 2004 Oi:21PM P1 Municipality Of Anchorage Department of Health and Human Services \~'~1/ 825 'L' Street ~ P.O. Box 196650 anchorage, Alaska 99519-6650 l~ick Mysttorn' h~,J/vnvw, c~a n~horage.ak.us Mayor Permit Number: #SW ,030138 Date of Issue: ,5-'I-03 P~.rcel Identification Number: 015-054-31 Date Started: 8-21-03 ,Date Completed: 8"21'03. ls well located at approved permit loc~tion? [~ Yes ["-] No Legal Description: Property Owner Name & Address: ~'~orehole Datai Autumn Ridge Lot 28 Crown Point Inc. PO Box 112313 Anchorage, Alaska 99511 Depth (ft) From To Method ofDrilllng [S/] air ro~z.,'y ~'] cable tool Casing type: stc~ Wall Th]6kn~ss: ,~$_@ inches Diameter: _6 inches Depth: 44 feet Liner Type: Diameter: inches Depth: feet Casing sficlmp above ground: _~ feet Static water level (from ground level): 26.__feet pnmping level:. 44 £c=t afar _.2 hours pumping 30 gpm Recovery Rate: 3_0. gpm Method of Testing: .air I~ Well Intake Opening Type: [~ Open End [~] Open Hole ]--] Screened Start feet Stopped _ feet [] Perforations Start feet Stopped__ feet Grout Type: bemoni~e ii 8 Volume: I bg Depth: Stat 0 feet Stopped ~ feet Pump: Intake Depth _. feet .Pump size hp Brand Name Well Disinfected Upon Completion? [~ Yes ~'] No Method of Disinfection: Comments: Well Driller: Alpine Drilling & Enterprises PO Box ~'i0496 Anchorage AJaske 9.951 f S0il Type, Thickness & W~t~r Strata stick-up 0 2 organics & silt 2 8 sandy silt 8 21 gravel 21 25 gra. velly silt 25 37 water sand & gravel 37 44 . 'owner ~4~- 30 ~s of completion and thc property  Atteuli0u: The well driller shall pw~id= a well log to thc property . ..... ,.,: .~ ~ ....~ ........ ,. MUNICIPALITY OF ANCHORA GE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: May 19, 2003 Expiration Date: May 18, 2004 Permit Number; SW030138 Legal Description: ~Autumn Ridge E(St 28, Design Engineer: 0014 Anderson Engineering Owner Name: Crown Pointe, Inc. Owner Address: P.O. Box 112313 Anchorage, AK 99511- Parcel ID: 015-054-31 Site Address: P.O. Box 112313 Lot Size: 40074 SQ. FT. Total Bedrooms: 5 Permit Bedrooms: 5 This permit is for the construction of: [~ Disposal Field [~ Septic Tank ~-~ Holding Tank [] Privy ~-~ Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Issued By: Parcel I.D. Municipality Of Anchorage Development sei-vices Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak, us (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Permit Number'SW Property owner(s). Crown Pointe, Inc. Mailing address (1) 'P.O. Box ~12313 Anchoraqe, AK 99511 Mailing address (2). Legal description (Lot, Block & Sub'd.) Lot 28, Autumn Ridge Subdivision Legal description (Section, Township & Range) Lot Size 40,074 SF Acres/Sq. Ft. Day phone 345.6277 .Zip Code THIS APPLICATION IS FOR: Sewer Only [] Sewer and'Well [] Sewer Upgrade [] THIS PROPERTY CONTAINS: Hot Tub [] Swimming Pool : [] Therapy Pool [] Number of Bedrooms Five (5) Well Only Water Sto~age Jacuzzi Water Softening Unit' [] [] [] [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property Owner or authorized agent) Permit Fees: ~-",_~) · O O Date of Payment: ~..11~/~'~ Receipt Number: JS~)"~,~ (Rev. 12/00) Waiver Fees: Date of Payment: Receipt Number: · ANDERSON:,ENGINEERiNG. ANCHORAGE, AK 99524 i,=-: 522-6779.:(FAX) May 13, 2003 Municipality of Anchorage Development Services Department .On-Site Water and Wastewater Program 4700 South Bragaw Street AnChorage, AK 99519-6650 Subject: Lot 28, Autumn Ridge Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 28, Autumn Ridge Subdivision intends to construct a five-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to serve the proposed home. The attached Site Plan and backup documentation identify the location and configuration of the new well and septic system and the parameters used in the design. Also identified on the plans are the locations of neighboring wells and septic systems, alternate absorption site and the test hole locations. Existing drainage patterns are shown and will not be altered by the construction of the new system. Test holes have placed on the lot during the subdivision phase indicate clean sandy gravel with percolation rates less than 1 minute per inch. Mom than 50% of the material encountered in the hole is less than %" in diameter. It is unnecessary to place a sand filter in this material. Groundwater was noted during.our field testing at 10' below the surface and has stayed at this level since the original placement of the holes even during high groundwater Periods. We are proposing therefore to construct a 5' wide absorption bed with 4' of gravel beneath the distribution pipe. The total depth of the trench will be 6' to maintain 4' separation from groundwater. Additional fill will be placed over the trench to provide 3' of cover. The ground surface on the lot slopes as shown on the attached Site Plan with a shallow slope near the proposed absorption trench. The new trench will be constructed on a fairly fiat surface in conformance with Municipal requirements and parallel to ground contours where possible. All components of the new septic system will be constructed a minimum of 100' from all wells in the area. Lot 28, Autumn Ridge May 13, 2003 Page Two If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Michael E. Anderson, P.E. Attachments / / 26 43,151 sq.ft. 40,262 sq. Sept I\ ;q.f 'EAST' AREA YST PLAN.,~~...., ................. ~...L, AUTUMN RIDGE SUBDIVISION LOT 28 ABBO'I'r'ROAD N 89'59'00"E 75,00' DRAINAGE I / BUFFER LAN: Proposed Well ESMT. ,/ / / DRP/EWAY FOR LOT 27 63' LonQ x 5' ~de x 4' E,ff~ctLye D.epth Absorption /rencn __ 1.500 Gollon Septic Tcnk ~ 10' , II Ntem~te ~t~ Faq SITE RN. FLR. EL - F~ve Bedroom Home x N 8g'55'51'£ 87.g0' SCALE PLAN l' = 40' LOT.28, AUTUMN RIDGE SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom House 5' Wide Trench System Perc. Rate: LT 1 Min./Inch 1,500 Gallon Septic Tank Application Rate: 1.2 GPD/SF 4' Drainfield Rock 5 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 625 SF Absorption Area 625 SF/5 LF (Width)* .5 (Red. Factor) = 62.5 LF Trench Length THEREFORE: Construct a 63' Long x 5' Wide x 4' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 2' Below Original Ground Surface. Total Depth to be 6' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. 4'0" Natural Backfill Geotextile % O Fabric 4" Perforated PVC (Holes Down) -- Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION (.o SCALE) ~,~ ............ _.- ~:....." _~.....~ ~o. NOTE: Grade Area Over Trench to Drain Away. ~'.~/' .,,,~. Minimum 6' Separation From Bedrock. ¢~,.':,..%,"~ ........ Minimum 4' Separation From Groundwater. ,/..E................... Minimum 10' Separation From Water Service Line. Minimum 100' Separation From Surface Water or Streams. ~-~.'... No. ~;.*'~;: .......... '.'- <~ Municipality of Anchorage Depadment of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST performed For: Bob Klein Legal Description: ,Lot 28. Autumn Ridge Subdivision SLOPE. I ' PTIOL 2 .. " ' TEsTHoLE NO. 44 4 .. ' . · 5 ' 8 . · · .Was Groundwater .. 9 Encountered? :Yes S · If Yes, What Depth? 10' L 10 Ground ' Depth to Water" .. . . O · -. Water· . After Monitoring '" 10' "' P '- - tl Date: . 1122/00 E Date performed: 12/7/99 SITE PLAN Reading Date Gross Net' Depth 3-o Net Time Time 'Water Drop 1 7-Dec 11:41 " 2.25", 2 11:43 2 8' ' 5.75" . 3 11:44 2" 4 '11:46 2 8" .'6" ' '5 ' 11:47 2" 6 11:49 2 7.75? · ' · 5.75".. · B(~ttom of ~ Hole  .. . ~ ~ ¢, ,, ~ · .. 18 19 . "t.~~ . Perc. Rate: LT 1 MinJInch Perc. Hol~ D~ameter: 6" .... ... ~ "' . Test Run Be~een 4 Ft. and 5' Ft.' ' .. ~,, -. Comments: ' Percolation Cavi~ Presoaked Prior to Testing:· '  Pedo~d I, Michael E: Anderson: Ced~ That ~is Test Was Pedorm~ By~ In Ac~rdance ~th All Stateand Municipal Guidelines In'Effect On This Date: ' 1120/00 Iff II II II II Il Ii i1 Municipality Of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650' SOILS LOG - PERCOLATION TEST Performed For: Bob Klein . Legal Description:. Lot 28. Autumn Ridge Subdivision " SLOPE Date Performed: SITE PLAN 2 3 '4 5 - 7 8 9 '10 11 13 PTIOL :rES'I'HOLE 'No: 45 Ground water. Bottom of. H01e -was Groundwater Enc~)untere(J? Yes .' !f Yes, What DePth?. ' 11' Depth to Water '- After Monitoring 11~ . Date: 1122100 S 'L 0 /.! 'Residing Date Gross ',let: . DepthTo Net 'Time Time' . Water Drop' 1 7-Dec 1:41 2" 2 '1:43 2~ .8" 6" · 3 .1:44 2" 4 1:46. 2 · 8" 6" 5 , 1:47, 2" ': ,.. 6 1:49 '2 8" 6". .Perc. Rate: LT 1 Min./Inch ' Perc. H01e Diameter: 6" . · Test R[Jn Between 4 Ft; and 5 Ft. " '-' ' Comments: P(~rcolation Cavity Presoaked Prior to Testing.' .... : ' ' ·' ·, Performed By: A.' Harala. I, Michael E. Anderson'. Certify That This Test Was Performed In Accordanc~ .With All State and Municipal Guidelines· In Effect On This Date: 1120/00 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 28, AUTUMN RIDGE SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,500-gallon septic tank at the location shown on the site plan. Work also includes the construction of.a new absorption trench 63' long by 5' wide by' 4' effective depth als0 at the location shown on the Site Plan. The total depth of the trench will be 6' below existing ground and the distribution pipe will be placed at 2' below the surface. All components of the new absorption trench and septic tank must be constructed a minimum of 100' from any surface water and 100' from wells in the area. A minimum of 4' of cover is required over the septic tank and 3' over the absorption trench. In lieu of cover 2" of direct bury insulation and 2' of cover may be placed. Construction shall be in accordance with the approved site plan, design drawings, 'Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater DispoSal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,500-gallon septic tank must be procured from a certified septic tank manufacturer if the existing tank is found to be defective. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. Lot 28, Autumn Ridge · May 13, 2003 Page 2 of 3 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. o A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between'the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in' diameter and installed at the locations shown on the design. The portion below ground must be perforated. Contractor shall verify the septic tank and drainfield are a minimUm 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. o Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. Lot 28, Autumn Ridge May 13, 2003 Page 3 Of 3 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing.. the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under'the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted'after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile 'fabric, gravel, distribution, piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. Parcel I.D. 015-054-31 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. p.O. Box 1'96650 Anchorage, AK 99519-6650 www. ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORIT:Y APP"R'~-,g,i- ........ ~ .............. i .................. FOR A SINGLE FAMILY DWELLING. HAA#, ~-~ L~'~ Expiration Date: ,~- 3' O ~7~ GENERAL INFORMATION Complete legal description Lot 28, Autumn Rid.qe Subdivision Location (site address or direCtions)= ~A"~l~ott Road Current Prop(#ty owner(s). Crown Polnte, Inc. Mailing address P.O. Box 112313 Anchora.qe, AK 995tJ Lending agency Day phone 345.6277 Day phone, . Mailing address Real Estate Agent .....'..Mailing Address ::Unless otherwise re'quested, HAA will be held by •SD for pickup. NUMBER OF BEDROOMS: TYpE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class - Public Water System Five (5) ,, Well Day phone. TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [] [] Individual Holding tank [] [] Community On-site ~ [] Public Sewer [] The Municipality of Anchorage Development serVi(~es Depadment (DSD) Issues certificates of Health Authority Approval (HAA) based only upon the representatio, ns given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply §ystem. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days'from the date of issue for properties served by a private or Class C well and may be reissued with new water Sampl~ results less than 30 days old. (Cedificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Static water leVel - ~ * 26 . ":;* ,:~ { '~ ; .... I;'~' *: * ' "~;'1' ~ i ;: ........ t' , , I' ~-odUction*' ' "30, , ' ,t~P.m. ' ' ;i.;.!' ........ .'--'r' g.p.m. We p ..- _ ....... WATER SAMPLE RESULTS: '" ' · _ ..;,i ~:~, ,i2 "'"'"';~'--'*' '~" Nitr~t~' 405 'm"/!~'';I~" :'"': '~Otherb'acteria u co~onles/1uuml. L;ollTorm u COlOnles/luU m~. · , Date'ofsample: 11912004 ', ,,. Collec!'.d Y. , , sEPTIc/HOLDING TANK DATA '. ' ...... t t ' i , f ..... Tan~ TvP~/Material '; septic/steel ,,.: ' ,' ,' .,~,T°n,k s ze''~', ~,500 ..oal. . ,: Number. of Co,mPa~tmepts ~,.,~;~,~,tio~ cleanout ~/N~ Y ' Depress on over tank (,Y/N) N :~ i" H gh w,@t,er ,a.,I,a,r~ (Y/N) N ,, .._,.~ x, _;~.~,~,t,,',, ' · . -. , , Pumoer .New Construction., ' ' ' ' Il ~ ' ; ' ''' ~ ~'' I ' ' ' ABSORP, TION FIELD DATA: ," ~"' "'-;~' '-"--'~ ~-' ='3~2003" ~' Soil ratinn In ln~/fit orftt/bdrm) '1.2 GPDISF I I !, i Sys,te,m, ,typ~ .5 W~de Trench SGS Ref.# Client Name Project Name/// Client Sample ID Matrix 1040255001 Anderson Engineering Lot 28, Autumn Ridge Lot 28, Autumn Ridge Drinking Water All Dates/Times are Alaska Standard Time Printed Date/Time 01/16/2004 15:09 Collected Date/Time 01/09/2004 10:45 Received Date/Time 01/09/2004 11:05 Technical Director ~.. Step~ C. Ede Sample Remarks: Allowable Prep Analysis Parameter Results PQL Units Method Container ID Limits Date Date Init Waters Department Total Nitrate/Nitrite 4.05 1.00 mg/L EPA 300.0 C 01/13/04 Microbiology Laboratory Total Coliform 3 OB, W/Fecal Coli col/100mL SMI8 9222B A (<=D 01/09/04 DKC ~~01119-04 06:29P~ 1 FROI, I--CT&E ESI, SGS ENV SERVICES 9075615301 :; SGS/C'rE .ENVIRONMENTAL SERVICES T-114 P.Ol/01 F-035 Drinking Water Analysis Report for Total Coliform Bacteria READ INSTRUCTIONS ON REVERSE SIDE BEFORE COLLECTING SAMPLE ' -MUST BE COMPLETED BY WATER SUPI~IER - ' [~ PUBLIC WATER SYSTEM ID# - . [~IVATE WATER SYSTEM [] Send Results [] Send Invoice '200 W. POTTER DRIVE ANCHORAGE, ALASKA 99518 Tel: 907-562-2343 Fax: 907-561-5301 " , 1040301 ,:llru ~ N.m~ar SAMPLE COLLECTION: Mon~ Day Year Transpo~ to ~] ~y= ~ Same as colle~or O~er: TO BE COMPLETED BY ~BORATORY ~ample Receivin~Date: ,(X~I 4 '1 Z. tpCm~e ....- .o SAMPLE TYPE: " [] Routine  Repeat Sample (refer to lab no. [] Special Purpose [] Sample over 30 hours old; Results may be unreliable · [] Treated Water [] Untreated Water [] RUSH SAMPLE Time: Temp: ~ \~' 4~ [] 48 Hour Waiver Phone #; Delivery Method: ¥'~.~ ~----' , For~ ~ PriSma Hame ~e comments: ..... ,iSent ~ ^DEC: ! Baclerioloqical Water Analysis Record_: I ANC FBK JUN MMO-MUG {P/A) RESULTS: IDate/Time: .... Anaty$1s BeD_an: ' i/Iq/Oq t~. tD __ Totm conform: I . L Analyst: ~ .. E. Coli: Analytical Method: [] Membrane Filter [~ MMO-MUG (P/A) Reported By:.s~t~ MEMBRANE FILTER RESULTS: Direct Count: VelSficatic~l: LBGB: \\pelt a\p ublic\DOCUMENT~FORM S~licr°\C°li Form.xls I Sent to Client: lPhoned Colooies/lo0ml ~Daterrime: lSpoke with: ... I~ Saiisfact~ry [~ Unsatisfactory Faxed r"-] TNTC re'Tea Numerous Oil · Other Bacteria Form # FW- 0053 1D/24/03