Loading...
HomeMy WebLinkAboutFROSTAD Lots 1, 2 & 3 Plat# 87-100 S-8458"Z.Y6s4-ad �� SL1S � (491'1-- lob*\ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION Environmental Health Division CASE REVIEW.WORKSHEET CASE NUMBER: S-8458 SUBDIVISION OR PROJECT TITLE: I DATE RECEIVED: i COMMENTS DUE BY: April 8, 1986 I May 2, 1986 Lots 1, 2 & 3 Frostad Subdivision. PUBLIC WATER AVAILABLE ( ) PUBLIC SEWER AVAILABLE COMMUNITY WATER AVAILABLE ~,~ ~ ~. ~ ~~ ~ ~ ~~ ~~, ~ ~--~2 .... September ll, 1987 Donna Frostad ... 12601 Hillside Drive Anchorage, Alaska 99516 Lot 2 Re: Frostad .tubdtvtston On August_~%t~ 1987 we drilled n testhole'lg'!feet Sou~h-east of the existing crlb.~-~/hsal was reached at 12 feet B-~ ;'.The hole was dry after one week. The percolation, rate on the soils was 42 ~inutes'per inch. ' · The irround surface"at the testhole was about 1.to'2 feet higher than at ~he · crib. The rater level in'the crib was higher 'than the bottom of the testhole. · It'is evident that there ts no g~oundwater .~[f~cttng the system. · The :second pipe appears to be a reverse cleanout, between the crib and the septic tank". "The m~asurement of the distances between the,septic tank and the crib are about the smae as shown on the original Inspection form. There is not enough 'distance for .there to have been two cribs. A lift station Will probably be needed'for any Upgrades on this lot. This'is .because the remaining ground ts higher in elevation than the 'existing system. If you have any questions please let me know. "· Susan Oswald Tom Sturgis Sincerely, 12gO UJesl 33roi /~.~nue. ~iI¢ B * Ancl~ore~e. Alesh' ~5o~ o(~o7'l 5e]-5o4o 'CC: PERFORMED FOR: LEGAL DESCRIPTION: 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O OF ~NGINEER*S SEAL) ~',~.' J-;"--"-~ e / Municipality of Anchorage5~r'O''~O:r~''~ "._'~ ~. / 825 "L" Street, Anchorage. Alaska 99502-~~K,- ~ ~ / so,~s ~o~ - .~.co~A~,o. ~~~:~ . / - ~ ~.. ....... · · ~ ~'~ w~5~........ -~L~ ~~. Township, Range,' Section: ~/Z~ ~ ~3: SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? S L IF YES, AT WHAT O DEPTH? '--'"" P E Depth Io Water Alter Monitoring? Reading Date Gross Net Depth to Net Time Time We~e~ ~ P Drol~-~¥) PERCOLATION RATE ~>~ (minutes/tach) PERC HOLE DIAMETER TEST RUN BETWEEN ~'~ FT AND , ~,,~'"-'* FT PERFORMED BY; ~--~nI /;.,~,z~ I / /l~j~ d/ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION ALASKA I1UII Ollm I1TAL COI1TI OL S RUIC S, II1C. [~nqineerin~ $ ~nuironmentol Sludies SOILS FCR THE PI~C~OSED F'R~ST~ SUBDIVISION Enclosed are the results of soil testing~ performed by Alaska Environmental Control Services~ Inc.~ (AECS)~ on 5 acres in NI/2~ SWI/~, N~/I/~, NWl/#, TI2N, R3W, Section 25, Seward Meridian. This area lies in the foothills of the Chugach lVbuntains east of Anchorage~ Alaska. The property slopes to the west with elevation ranging from 1000 to 1120 feet. The site is adjacent to~ and accessed from the west by Hillside Drive. Current improvements consist of a single family house. Vegetation consists of mixed spruce and birch trees~ with aider dominating the rno~e open areas. The soils grade from SILTY SAND (SM) to (]~A~LY SILT ([VL). Bedrock was found at 10 feet in a testhole in the southwest part of the property. DISCUSSION: Tests were performed' in conjunction with the requirement~ set forth in "Design Manual for On-Site Wast·water Treatment and Disposal Systems"~ published by the E.P.A. The testholes were dug.by aC asa 450 backhoe on March 2#~ and 26~ 1986. The objective of our testing was to determine the soils suitability for on-site septic systems. The important soils characteristics are 1) SOIL DEFTH (depth to bedrock); 2) DEPTH TO(2~UNDWATER~'and 3) SOIL PEI~39IJkTION P,A, TE.' Refer to the Appendix .for individual testhole soil logs. SHALI.O,V SOIL.' Testhole three~ located in the southwest part of property~ identified bedrock at 10 feet. Based on interpretation of vegetation types and prior experience of the excavator~ we surmise the bedrock.'lies at this' elevation on the lower part of property in a North-South direction. Bedrock at 10' along with 15% slope v~uld require an engineer designed shallow septic system. SOIL T~,TER: No groundwater was observed in any of the testholes. Water monitor tubes were installed in all the holes to facilitate monitoring for seasonal highwater at a later date. SOIL ~TION' RATE: All testholes identified soil with acceptable percolation 'rates. Values ranged from 153 to 257 square feet per bedroom. It should be 1200 UJest 33rd Au·hue, Suite B · Anch0ra~e, Alaska 99503 ·(907) 561-5040 noted that these soils ratings, although acceptable, will require allocation of significant areas of the proposed lots for primary septic systems and replacement areas. (X:IqO~SIONS:. Our soil investigation identified suitable soil for septic systems in. all four testholes. However, because of the general slope of the entire property is around 15%, trench type absorption systems installed along contour lines will be required. Bed type systems are probably excluded because they mist be installed level. Caution is advised in the development'of building sites, driveways and well sites so that sufficient area is set aside for a primary and replacement septic areas. If septic systems are installed at the locations of testholes I and 2, a lift station may be required, depending upon placement of the building sites. An engineer designed shallow system' will be required to overcome the shallow bedrock and slope found at testhole 3. Seasonal groundwater rmnitor data will be gathered and added to this report, AECS plans at least two iTonltor visits. If you have any questions, please call. Sincerely, Denni s Roe Field Engineer Approved by: Attachments: Site Plan Percolation Tests ALASKA ENVIRONMENTAL CONTROL SERVICES, INC. 12OO West 33rd Avenue, Suite B ANCHORAGE. ALASKA 99503 (907) 561.5040 JOB SHEET NO CALCULATED BY CHECKED BY SCALE /Cc,/ DATE ~'..~7--~ DATE PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, AnchOrage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST (EN~EAL) DATE PERFORMED: LEGAL DESCRIPTION: /~ ~ (' ~'~ ~C/ /{J(,U Township, Range, Section:/n~/~r..¢./., ._~,¢ .o,,~,~-- " - SLOPE SITE PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 16 17 18 .19 20 COMMENTS WAS GROUND WATER ENCOUNTERED? S L IF YES, AT WHAT O DEPTH? Depth to Water After MonitorinD? Date: ' Gross Net Depth to Net ' Reading Date Time Time Water Drop PERCOLATION RATE ~-~.' ~;~ (minutes/,nch) PERC HOLE dIAMETER TEST RUN BETWEEN q.O FTAND Z~.( FT ~,CCORDANI~E WiTH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT O'1~ THIS DATE. 72-001~ (Rev. 4/8~)' ' " CERTIFY THAT THIS TEST WAS PERFORMED IN DATE: --~ ~--~?F" '~:~ ' Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEsT 1 2 3 4 5 6 '7 8 9 10 11 12 13 14' 15 16 17 18 19 2O WAS GROUND WATER ENCOUNTERED? DATE PERFORMED: (ENGINEER~,, EAL) Township, Range, Section: ,/'~.~.,~ ~_~, -~"~"c- ~'- SLOPE ~ ~ITEfPLAN ! L IF YES, AT WHAT. O DEPTH? p, E: Depth la Water Alter Monitoring? Date: Gross Net Depth to Net Reading Date Time Time Water Drop ~II~0 .~ 11;¢0. o,.t~O PERCOLATION RATE I(o ~ Cm,nutes/,nch) PERC HOLE DIAMETER ~ '' DATE' -~'--~ .~ '--~ ' (~2-008 (Rev. 4~85) Municipality of Anchorage ' DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: ~ LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11 12 (ENGINEER~EAL) DATE PERFORMED: -~-,.~'~--~'- Township, Range, Section: "j"/~,,~/ SLOPE . 'SITE PLAN WAS GROUND WATER' ENCOUNTERED? S L IF YES, AT WHAT O DEPTH? p E Depth I~ Water Alter - Monitoring? Date: 13 14 15 16 17 18 19 20 Gross Net Depth to Net Reading Date Time Time Water .Drop PERC'OLATION RATE TEST RUN BETWEEN ACCORDANCE WITH ALL STATE AND MUNICIPAi~ GUIDELINES IN EFFECT ON THIS DATE. (minutes/inch) PERC HOLE DIAMETER FT AND~'0 FT CERTIFY THAT THIS TEST WAS PERFORMED IN . DATE: 72-008 (Rev. 4185) PERFORMED FOR: LEGAL DESCRIPTION: 1 ~ 2 3 4 ~' g ! 11 . 12 : .; 13 14 .-. ~ 16- 17 18 19 20 Municipality o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST DATE PERFORMED: ( ENGI~R'S SEAL) \r~ ~/AS GROUND WATER ~~ ? ~NCOUNTE~ ED? ~~ /5'0 ,~ yES, ~, DEPTH~ Township, Range, Section: j',,,~.~.j~ SLOPE SITELPLAN /4O S .L 0 P E. Depth to Water Alter Monitoring? Date: Gross Net Depth to Net Reading Date Time Time Water Drop ~0 lq~/ ~ ~ ~ ~ "~ PERCOLATION RATE -,~-.'~- ~' {m~nutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~',"~ FT AND COMMENTS PERFORMED BY: /..~'~ ~'<::~ . ~...t.~; I ACCORDANCE WITH ALL STATE AND' MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. CERTIFY THAT THIS TEST WAS PERFORMED IN (~8 (Rev. 4/85) ALASKA ,,,JIROII[IleI1TAL COI1TROL S i,,,IC(5, II1C. June 30, 1986 Tryck Nyman & Hayes 911W. 8th Avenue Anchorage, Alaska 99501 Attn: Dave Munferd Re: Proposed Frostad Subdivision, Soil Investigation N1/2, SWl/4, NWl/4, NWl/4, Section 25, T12N, R3W, S.M.. Alaska Dear Dave: This is a report on the results of monitoring for the presents of groundwater tn test holes performed by AECS. Inc. in March of this year. Results are tabulated below. Testhole Number Date I 2 3 4 April 2, 1986 12' (dry) 8.5' (dry) 12' (dry) 17.5' (dry) May 2, 1986 13' (water) 8' (dry) ll.5'(dry) 17' (dry) June 4, 1986 13' (dry) 8' (dry) ll.5'(dry) 17' (dry) Notes: All measurements.are referenced to ground surface. Discrepancies between testhole depths from soil logs and water monitor levels may be due to snow peak or settling of the ground in and around the investigation. (1) Testholes I and 2 were completely buried by snow making exact measurement to ground surface difficult. (2) Ice may have been present at the time of measurement. If you have any questions please feel free to call me at 561-5040. Sincerely, F. Cords Civil Engineer ALASKA ENVIRONMENTAL CONTROL SERVICES, INC. 1200 West 33rd Avenue, Suite B ANCHORAGE, ALASKA 99503 (907) 561-5040 JoB /__or' / SHEET NO. CALCULATED BY CHECKED BY SCALE OF DATE .... /_ ..... ~_ :.-. ~.-~. .......... .~,. - /' ,'~- ~....~ ..... i.. :" "i/ ' "~;" ~'"':"': .... : 'i"':~ "':' ...... ~ ...... :" =. .: ........ ~... ~ ..:. .... : ............ ~ ..... ; .......... ~ .......... : ..................... .......... ........ ; ........ ............ !.: ..... · ,'. ....................... ~-,,.~...i ......... ! ....... 1..._ ................. ,~ ~.. ..... ~ ................ : ...::",, ..... ; ........... : .......... ; ........... : .............. ~ ................... _~._~ ..... ='\'": ......... t ..... : .......... ,~ ..................... ~ ......... : ......... : .......... ~"' ~ , ~" ' ' i: ' ~ _N. ~ _i .... i ................ ..... ~.~... - ' ',~ ',4 ~ : ~ ' ................ ~...\ , ~.. ~ ...... ,~ ................................ ~...? ...... ..... :.. ~ ...... i,~ ......... .~. ,~ .... : ..... i~... ....... [ .......... i ............ } .................. N ~. '~ ~ t~ . " : ; ...~,. ~ ...... :..~ ...... ,~ ~.~.:. .... /, .... :: .......... ~. ........ ~ ............. ...... ,j .. ~ .......... : ......... ~ ~-~ ~/ ,,. . .~.~-.. ......... ! .... ¢ ............. ~ ........ ~.. ~..-~ ....... :~...:' ~. ........ :~..~::~..~ ! ::. ~ . · . ~ ~, ....... · ...., ~,~,~,,,~,,,~,~. ~. ~,.,-,,%~ ....... .~..~ ............. : ...... ~,---..,.~. . .~ ~ ........... : . ~ : : : ! : : . . .. .... . '~,~,.,.~.~a~.~,....~,.z~,-7 .-..' ........ ~,,.: ..................... : ................ . ;. ...... ,, ..... = , . . '% :~..., :,,-,,,,. ..... ,,,,,.,,~,,,:,..~,- ,,.,,., ~ ...... ! ..................... . ................. .',,.,,~'....-..... : ........... ...; ...... ,~- .... · ,.,~'Z~ ' - - .~,, : : . . ~ ,¢- ~ ~ t\, ,~.~ .'~.,. ~ ...... :'~~: .... ': .... ~ ....... ~, ...... ~'"'1~~::~ .... ALASKA I FIUIROFImi rlTAL-COFITROL $1 RUICI $, IRC. J~nqin¢~rinq ~ J~nuironmenlaJ Studies SPECIFICATIONS FOR A DEEP TRENCH WASTEWATER TREATMENT SYSTEM- ~FROSTAD SUBDIVISION, LOT ! 1~0 GENERAL 1.1 THE DRAWINGS, SHEETS 1 THROUGH 3, St~LL BE A PART OF THIS SPECIFICATION. 1.2 ALL MATERIALS AND WORKMANSHIP SI~LL MEET THE 'REQUIREMENTs OF THE STATE OF ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION (ADEC), THE CONDITIONS OF THE PERMIT, AND ALL APPLICABLE RULES AND REGULATIONS CURRENTLY IN EFFECT. 1.3 ALL ELEVATIONS AND DEPTHS ARE ADVISORY, AND ARE TO BE VERIFIED OR MODIFIED IN THE FIELD BY THE ENGINEER, OR INSPECTING AGENCY. 1.4 IT IS THE RESPONSIBILITY OF THE OWNER OR INSTALLER TO ADHERE TO APPROVED DESIGNS FOR INSTALLATION, MAINTAIN THE SPECIFIED SEPARATION DISTANCES, AND TO HAVE APPROPRIATE INSPECTIONS. 1.5 IF THE INSTALLATION IS NOT INSPECTED BY AN AECS ENGINEER, AECS WILL NOT BE RESPONSIBLE FOR TIlE INSTALLATION. AN ENGINEER AT AECS StlOULD BE CONSULTED PRIOR TO CONSTRUCTION, TO DETERMINE THE NUMBER OF INSPECTIONS THAT WILL BE REQUIRED AND TO EXPLAIN WHAT THESE INSPECTIONS WILL INVOLVE. 2.0 SEPTIC SYSTEM 2.1 THE SEPTIC TANK St~LL BE A UPC APPROVED TWO- · COMPARTMENT TANK CONSTRUCTED.OF 12 GUAGE STEEL WITH BITUMASTIC COATING, SET.LEVEL, AND INSULATED WITH AN OVERLYING LAYER OF 2-INCH BURIAL TYPE POLYSTYRENE RIGID BOARD'INSULATION. THE SEPTIC TANK SHALLREST ON UNDISTRUBED SOIL. 2.2 INLET AND OUTLET PIPING SIIALL BE FITTED WITH WATER- TIGHT CALDER COUPLINGS. PIPING SHALL BE 4 INCH SOLID PVC D$034, OR CAST IRON, SLOPED A MINIMUM OF 1/4 INCH PER FOOT, WITH A MINIMUM OF 4 FEET OF COVER. 2.8 CLEANOUTS SHALL BE INSTALLED AS DESIGNATED AND CAPPED WITH AIR-TIGHT RAIN CAPS (JIM-CAPS OR EQUIVALENT), AND EXTEND A MINIMUM OF 2 FEET ABOVE GROUND LEVEL. 2.4 THE SEPTIC TANK SHALL BE A MINIMUM OF 5 FEET FROM THE HOUSE FOUNDATION, AND A MINIMUM OF 10 FEET FROM THE DRAINFIELD. 2.5 THE SEPTIC TANK SHALL BE A MINIMUM OF 100 FEET FROM ANY PRIVATE WELL OR BODY OF WATER, AND FEET FROM CLASS C WELLS, AND 200 FEET FROM CLASS A OR B WELLS, UNLESS OTHERWISE SPECIFIED. LESS THAN 1200 [Uesl 33rd Aucnu¢, Suil¢ B · Anchoraqe, Alaska 99503 · [907) 561-5040 3.0 THE REQUIRED SEPARATION DISTANCE MUST HAVE PRIOR 'APPROVAL OR WAIVER BY ADEC. SEEPAGE TRENCH 3.1 THE GRAVEL FOR THE TRENCtl SHALL BE 0.75 TO 2.5 INCH SCREENED ROCK WITH LESS THAN 3 PERCENT PASSING THE NO. 200 SIEVE. ALL SUBSTITUTES MUST HAVE PRIOR ADEC APPROVAL. 3.2 TIlE BOTTOM AND SIDES OF THE EXCAVATION SHALL BE RAKED WITH THE BACKHOE BLADE TO INSURE THAT THE BOTTOM HAS NOT BEEN COMPACTED DURING EXCAVATION. THE'BOTTOM OF THE EXCAVATION SHALL BE LEVEL. 3.3 THE DISTRIBUTION PIPE SHALL BE PERFORATED 4 INCH RIGID PVC WITH A MINIbfUbi CRUSH STRENGTH OF 1500 POUNDS. ALL PIPES SHALL BE PLACED LEVEL AND POSITIONED ACCORDING TO THE DRAWINGS. ASTM D2729 WILL NOT BE ACCEPTED BY THE INSPECTOR. 3.4 MONITOR PIPES SHALL BE PLACED AS SHOWN IN THE DRAWINGS. THESE SHALL BE 4 INCH RIGID PVC, ASTM D-3034, OR CAST IRON. THE SECTION SHOWN WITH THE HOLES MAY BE EITHER DRILLED 0.5 INCH DIAHETER HOLES ON 6 INCH CENTERS ON OPPOSING SIDES OF THE PIPE OR A REGULAR SECTION OF PERFORATED DISTRIBUTION PIPE F~Y BE CLAMPED TO THE SOLID SECTION WITtt A NO HUB COUPLING OR SOLVENT JOINT. PERFORATED SECTION SHALL BE LOCATED IN THE SEWER ROCK ONLY. THE PORTION OF PIPE ABOVE THE SEWER ROCK SHALL BE SOLID. A RUBBER RAIN-CAP (JIMCAP OR EQUIVALENT) SHALL BE PLACED OVER THE TOP OF TIlE PIPE 3.5 THE GRAVEL SHALL BE COVERED WITH A LAYER OF A NON- WOVEN FABRIC (SUCH ASMIRAFAI, TYPAR, POLY-FILTER X, OR EQUIVALENT.) 3.6 IF INSULATION IS USED, THE INSULATION SHALL BE BURIAL TYPE POLYSTYRENE RIGID BOARD INSULATION. THERE SHALL BE ONE INCH OF INSULATION FOR EVERY FOOT OF SOIL LESS TtlAN THE REQUIRED 4 FEET OF COVER, BUT THERE MUST BE AT LEAST 24 INCHES OF SOIL OVER THE INSULATION. THE SOLID PIPE EXTENDING FROM THE SEPTIC TANK TO THE DRAINFIELD SHALL HAVE 4 FEET OF COVER OR ANEQUIVALENT-LAYER OF INSULATION COMBINED WITH SOIL TO PREVENT FREEZING OF THE PIPE. 3.7 THE AREA EXCAVATED IN THE VICINITY OF THE TRENCH SHOULD BE PLANTED WITH A WHITE CLOVER AND RED FRESCUE MIX OR BLUEGRASS. 4.0 INSPECTIONS 4.1 A MINIMUM OF TWO INSPECTIONS WILL BE REQUIRED. THE FIRST INSPECTION WILL BE OF THE OPEN EXCAVATION, TO INSURE THAT THE SYSTEM IS PLACED IN THE PROPER STRATA, CORRECT DEPTH AND MEET MINIMUM SPECIFIED DESIGN PARAMETERS. 4.2 THE SECOND INSPECTION WILL BE AFTER PLACEMENT OF GRAVEL, MONITOR STANDPIPE(S), AND DISTRIBUTION PIPE, TO.VERIFY PROPER INSTALLATION AND POSITION OF PIPES PRIOR TO BACKFILL.